QA Test Report - Elmarksupport.elmark.com.pl/moxa/products/Switche_przemyslowe/... · 2009. 8....
Transcript of QA Test Report - Elmarksupport.elmark.com.pl/moxa/products/Switche_przemyslowe/... · 2009. 8....
-
MOXA
QA Test ReportI .J
Report Number: DVEAA0612
Project Number: NP05092201&NP05092201-1
Products Model: EDS-316 Series
(Product Environmental Test)
Temperature Cycle & High Temperature High Humidity operation TestLow Temperature Power ON/OFF TestTemperature & Humidity Storage TestVibration TestShock Test
Drop Test
QA Manager: ~I\~->I-o (, Prepare By :-A)",v0 CfA.04 - 2- I '-"Cl~'
Moxa Technologies Co., Ltd.
-
QA Test Report
Report Number:DVEAA06012 Page:2/32
Table of Contents 1.Product Specifications ---------------------------------------------------------------- 3 2. Temperature Cycle & High Temperature High Humidity operation
Test----------------------------------------------------------------------------------------- 4 3.Low Temperature Power ON/OFF Test ------------------------------------------ 7 4.High Temperature High Humidity Storage Test------------------------------- 9 5.Low Temperature Storage Test --------------------------------------------------- 11 6.Vibration Test --------------------------------------------------------------------------- 13 7.Shock Test-------------------------------------------------------------------------------- 24 8.Drop Test --------------------------------------------------------------------------------- 30
-
QA Test Report
Report Number:DVEAA06012 Page:3/32
Product Specifications Power Requirements Power Input:12~ 45 VDC Environmental Operating Temperature: 0 ~ 60℃ Operation Humidity:5 ~ 95% Storage Temperature:- 40 ~ 85℃ Storage Humidity:95% max.
Fiber Connector
10/100M Ethernet RJ45
Power Input 12~48 VDC
-
QA Test Report
Report Number:DVEAA06012 Page:4/32
Temperature Cycle & High Temperature High Humidity Operation Test
Product Model:EDS-316 Series Test Period:From 12-16-05’ PM 21:48
To 12-18-05’ AM 12:13 Sample Source:Engineering Sample Test Standard:IEC-68-2-3 Samples Q’ty:6Units Test N:Change of Temperature Test Sample S/N:EDS-316-01、EDS-316-02、EDS-316-03、
EDS-316-SS-SC-80-01、EDS-316-SS-SC-80-02、EDS-316-SS-SC-80-03 Test Condition:
1. High Temperature:60℃ 2. High Humidity:95%RH 3. Room Temperature:25℃ 4. Room Humidity:45%RH 5. Retention Period:36.5Hr 6. Temperature Slope:1℃/min 7. Input Voltage:DC 24V
Test Environment Curve:
Humidity
95﹪
45﹪
0﹪ High Temperature
60℃
25℃
-5℃ Low Temperature
0 1 1.5 3.5 4.5 6.5 7.5 9.5 10.5 34.5 35.5 36.5Hr
-
QA Test Report
Report Number:DVEAA06012 Page:5/32
Test Method: 1.Power ON and run the auto program with full cycle。 2.Do not need to remove the test sample’s power supply , when temperature or
humidity is changing。 3.After auto test is accomplished , put the test samples under 25℃ for full function
test。 4.Checking samples appearance and function。
Photograph:
airU2
U10
Fiber
D6
U1
-
QA Test Report
Report Number:DVEAA06012 Page:6/32
Proceedings: Temperature / Humidity
12-16 12-17 12-18 DATE Check Item PM AM PM AM
Check Time 22;49 11:50 17 : 50 08:33 Temperature 25.0℃ 59.9℃ 60.0℃ 59.9℃
Humidity(%) 45.0% 95.0% 95.0% 95.0% Components & Location Test ambient
D6 (Diode 100V 16A) 43.4 77.2 77.2 77.2
U10 (IP1718) 49.2 82.7 82.7 82.6
Fiber U1 (Transceiver SC1315-40APO(WT1) 46.6 79.8 79.5 79.6
Power air 46.9 79.9 79.8 79.6
Power U1 (REGULATOR L4973D3.3) 48.0 81.4 81.4 81.4
Power U2 (REGULATOR L4973D3.3) 50.0 83.2 83.2 83.2
Test Result:PASS
1. Visual Inspection:Products exterior and structure without any non-conforming condition。
2. Electronic Function:Products function without any error。 Test Equipments:
1. Temperature / Humidity Chamber:KSON THS-E4C-100 2. Temperature Recorder:TECPEL DTM-319
Test Location:MOXA Quality Assurance Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:7/32
Low Temperature Power ON/OFF Test Product Model:EDS-316 Series Test Period:From 12-18-05’ PM 12:14 To 12-19-05’ AM 12:13 Sample Source:Engineering Sample Samples Q’ty:6 Units Test Sample S/N:EDS-316-01、EDS-316-02、EDS-316-03、EDS-316-SS-SC-80-04、
EDS-316-SS-SC-80-05、EDS-316-SS-SC-80-06 Test Condition:
1. Low Temperature:-5℃ 2. Low Humidity:0%RH 3. Power ON Time:3Min 4. Power OFF Time:2Min 5. Room Temperature:25℃ 6. Room Humidity:45%RH 7. Retention Period:15.5Hrs 8. Test Time:12Hrs 9. Temperature Slope:1℃/min
10. Input Voltage:DC 24V Test Environment Curve:
Humidity
45﹪
0﹪
High Temperature
25℃ -5℃
Low Temperature 0 1 1.5 25.5 26 27 Hr
-
QA Test Report
Report Number:DVEAA06012 Page:8/32
Test Method: 1. Power ON for 3 min to make sure the sample work properly , then power
OFF for 2 min to make sure the sample stops without any further action。 2. Repeat step1 150 times till power ON/OFF test is finished。 3. After auto test is accomplished , put the test samples under 25℃ for full
function test。 4. Checking samples appearance and function。
Test Result:PASS
1. Visual Inspection:Products exterior and structure without any
non-conforming condition。 2. Power ON/OFF:The products is distinguished in heat and low temperature
conditions the progress power on/ off tests 300 times, non - creation any bad question。
3. Electronic Function:Products function test without any error。
Test Equipments: 1.Temperature / Humidity Chamber:KSON THS-D4C-100 2.Auto Power ON/OFF tester (DSR)
Test Location:MOXA Quality Assurance Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:9/32
High Temperature High Humidity Storage Test Report
Product Model:EDS-316 Series Test Period:From 03-30-06’ AM:10:23 To 03-31-06’ PM:14:59
Sample Source:Finished products Samples Q’ty:1 Units Test refer Standard:IEC-68-2-48
Guidance on application of the test of IEC68 to simulate the effects of storage Test Sample S/N:axdNC0700005 Test Condition:
1. Room Temperature:25℃ 2. Room Humidity:45% 3. High Temperature:90℃ 4. High Humidity:95%RH 5. Retention Period:24Hr 6. Temperature Slope:1℃/min
Test Environment Curve:
Humidity 95﹪ 45﹪
High Temperature
90℃
25℃ Temperature
0 1 2 26 27 28 Hr
-
QA Test Report
Report Number:DVEAA06012 Page:10/32
Photograph:
Test Result:PASS
1. Visual Inspection:Products exterior and structure without any non-conforming condition。
2. Electronic Function:Products function test without any error。
Test Equipments: 1. Temperature / Humidity Chamber:KSON THS-D4C-100
Test Location:MOXA Quality Assurance Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:11/32
Low Temperature Storage Test Report
Product Model:EDS-316 Series Test Period:From 03-31-06‘ PM:16:46 To 04-01-06’ PM:21:19
Sample Source:Finished products Samples Q’ty:1 Units Test refer Standard:IEC-68-2-48
Guidance on application of the test of IEC68 to simulate the effects of storage Test Sample S/N:axdNC0700006 Test Condition:
1. Room Temperature:25℃ 2. Room Humidity:45% 3. Low Temperature:-40℃ 4. Low Humidity:0%RH 5. Retention Period:24Hr 6. Temperature Slope:1℃/min
Test Environment Curve:
Humidity 45%
0%
Temperature 25℃
-40℃ Low Temperature
0 1 2 26 27 28 Hr
-
QA Test Report
Report Number:DVEAA06012 Page:12/32
Photograph:
Test Result:PASS
1.Visual Inspection:Products exterior and structure without any non-conforming condition。
2.Electronic Function:Products function test without any error。
Test Equipments: 1. Temperature / Humidity Chamber:KSON THS-D4C100
Test Location:MOXA Quality Assurance Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:13/32
Vibration Test Report Product Model:EDS-316 Series Test Date:01-13-06’、04-06-06’
Test Samples:17 Units Sample Source:Engineering Sample、Finished Product Test Standard:IEC-68-2-6 Test Fc and guidance:Vibration sinusoidal
IEC-68-2-34 Test Fd:Random vibration wide band General requirements
Test Sample S/N:1. Sine vibration test(Resonance Search) & (Operation) EDS-316-SS-SC-80KM
2. Random vibration test(Package) axdNC0700007、axdNC0700006、axdNC0700005、axdNC0700003、axdNC0700010、axdNC0700008、axdNC0700004、axdNC0700001、axdNC0700009、axdNC0700002、axgNC0900005、axiNC0700002、axiNC0700001、axiNC0700005、axiNC0700004、axiNC0700003
-
QA Test Report
Report Number:DVEAA06012 Page:14/32
Test Condition: Test Environment 1. Test Environment:20 +/- 2℃ 2. Test Humidity:70 +/- 20%RH (1) Sine vibration test(Resonance Search) 1. Frequency:5~500 Hz 2. Accelerate:1g 3. Sweep cycle:1Oct/min 4. Test Axis: X,Y,Z Axis 5. Test Time:13 min 17 sec(each axis) 6. Total Test Time:39 min 51 sec
(2)Sine wave vibration test(Operation) 1. Frequency:2~100 Hz 2. Accelerate:0.7grms(13.2~100Hz) 3. Displacement:2mm(p-p)(2~13.2Hz) 4. Sweeping Rate:1 Oct/min 5. Test Axis: X,Y,Z Axis 6. Test Time:1 hr 30 min 19 sec(each axis) 7. Total Test Time:4 hrs 30 min 57 sec
(3)Sine wave vibration test(Operation) 1. Frequency:3~150 Hz 2. Accelerate:1grms(9~150Hz) 3. Displacement:7mm(3~9Hz) 4. Sweep cycle:1Oct/min 5. Sweep cycle: 10 cycle 6. Test Axis: X,Y,Z Axis 7. Test Time:1 hr 52 min 54 sec(each axis 8. Total Test Time:5 hrs 38 min 36 sec
(4)Random vibration test(Package) 1. Frequency:5~500 Hz 2. Accelerate:3.0 g rms 3. P.S.D:0.0181854 g2/Hz 4. Test Axis: X,Y,Z Axis 5. Test Time:1 hr(each axis) 6. Total Test Time:3 hrs
-
QA Test Report
Report Number:DVEAA06012 Page:15/32
Test Photograph: Sine vibration test (Resonance Search) Sine wave vibration test (Operation)
Axis X
Axis Y
Axis Z
-
QA Test Report
Report Number:DVEAA06012 Page:16/32
Random vibration test (Package) Axis X
Axis Y
Axis Z
-
QA Test Report
Report Number:DVEAA06012 Page:17/32
Test Frequency Curve: 5~500Hz 7mm 1g Resonance Search Axis X
Axis Y
-
QA Test Report
Report Number:DVEAA06012 Page:18/32
Axis Z
2~13.2~100Hz 2mm 0.7g Operation Axis X
-
QA Test Report
Report Number:DVEAA06012 Page:19/32
Axis Y
Axis Z
-
QA Test Report
Report Number:DVEAA06012 Page:20/32
3~9~150Hz 7mm 1g Axis X
Axis Y
-
QA Test Report
Report Number:DVEAA06012 Page:21/32
Axis Z
-
QA Test Report
Report Number:DVEAA06012 Page:22/32
Test Frequency Curve: 5~500Hz 3.0grms Package Axis X
Axis Y
-
QA Test Report
Report Number:DVEAA06012 Page:23/32
Axis Z
Test Result:PASS
1. Visual Inspection:Products exterior and structure without any non-conforming condition。
2. Electronic Function:Products function test without any error。 Test Equipments:
1. Vibration Tester:KING DESIGN (KD-9363EM-600F2K-50N120, S/N:KDS11054786)
2. Controller:DACTRON (FRONT-End Box ,S/N:4529465) 3. Control Accelerometer:Wilcoxon Research (WR-777,S/N:3425) 4. Vibration Tester:KING DESIGN (KD-9363EM-600F2K-50N120,
S/N:KDS11054783) 5. Controller:DACTRON (FRONT-End Box ,S/N:5250251) 6. Control Accelerometer:Wilcoxon Research (WR-777,S/N:4208) 7. Vibration Tester:KING DESIGN (KD-9363EM-1000F2K-50N120,
S/N:KDS11054986) 8. Controller:DACTRON (FRONT-End Box ,S/N:4529465) 9. Control Accelerometer:Wilcoxon Research (WR-777,S/N:3425)
Test Location:KING DESIGE Vibration Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:24/32
Shock Test Report Product Model:EDS-316 Series Test Date:01-13-06’ Sample Source:Engineer products Test Samples:1 Units Test Standard:IEC-68-2-27 Test Ea:Shock Test Sample S/N:EDS-316-SS-SC-80KM Test Environment:
1.Test Environment:20 +/- 2℃ 2.Test Humidity:70 +/- 20%RH
Test Condition:
1.Accelerate:15g 2.Duration:11ms 3.Test Axis:+/- X,Y,Z Axis 4.Test Times:3 Shock / Axis 5.Operation Test
-
QA Test Report
Report Number:DVEAA06012 Page:25/32
Test Photograph:
Axis ±X
Axis ±Y
Axis ±Z
-
QA Test Report
Report Number:DVEAA06012 Page:26/32
Test Frequency Curve: Axis X
Axis -X
-
QA Test Report
Report Number:DVEAA06012 Page:27/32
Axis Y
Axis –Y
-
QA Test Report
Report Number:DVEAA06012 Page:28/32
Axis Z
Axis –Z
-
QA Test Report
Report Number:DVEAA06012 Page:29/32
Test Result:PASS 1.Visual Inspection:Products exterior and structure without any
non-conforming condition。 2.Electronic Function:Products function test without any error。
Test Equipments: 1.Vibration Tester:KING DESIGN (KD-9363-1000F2K-50N120,
S/N:KDS11054783) 2.Controller:DACTRON (FRONT-End Box ,S/N:5250251) 3.Control Accelerometer:Wilcoxon Research (WR-777,S/N:4208)
Test Location:KING DESIGE Vibration Laboratory
-
QA Test Report
Report Number:DVEAA06012 Page:30/32
Drop Test Report Product Model:EDS-316 Series Test Date:03-15-06’ Sample Source:Finished products Test Samples:16Units Test Standard:IEC-68-2-32 Test Ed:Free fall Test Sample S/N:axdNC0700007、axdNC0700006、axdNC0700005、axdNC0700003、
axdNC0700010、axdNC0700008、axdNC0700004、axdNC0700001、axdNC0700009、axdNC0700002、axgNC0900005、axiNC0700002、axiNC0700001、axiNC0700005、axiNC0700004、axiNC0700003
Test Condition:
1. Test Phase:One Corner、Three Edges、Six Faces, Total Ten Drops 2. Test Height:90cm 3. Package Weight:22.90Kg 4. package Dimension:51.8 ㎝(L)×41.8 ㎝(W)×40.5 ㎝(H)
Test Drawing:
1 Rear Side 6 Top Side
2 Left Side
4 Right Side 5 Front Side
3 Bottom Side
Mid Edge
Damage Corner
Short Edge
-
QA Test Report
Report Number:DVEAA06012 Page:31/32
Test Sequence:
Sequence # Orientation Specific face, edge or corner 1 Corner most fragile face-3 corner, if not known, test 2-3-5 2 Edge shortest edge radiating from the corner tested 3 Edge next longest edge radiating from the corner tested 4 Edge longest edge radiating from the corner tested 5 Face one of the smallest faces 6 Face opposite small face 7 Face one of the medium faces 8 Face opposite medium face 9 Face one of the largest faces
10 Face opposite large face Photograph:
Corner
Three Edges
-
QA Test Report
Report Number:DVEAA06012 Page:32/32
Six Faces
Test Result:PASS
1. Visual Inspection:Products identity exterior and structure without any non-conforming condition ,the Products Gift box damages accept。
2. Electronic Function:Products function test without any error。
Test Equipments:KING DESIGN KD -128 Test Location:MOXA Quality Assurance Laboratory