PWS2014 Rawlins DesanderStudyR
-
Upload
jhon-henry-segundo-llaguento -
Category
Documents
-
view
222 -
download
0
Transcript of PWS2014 Rawlins DesanderStudyR
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 1/10
Study on the Interaction of a Flooded Core Hydrocyclone (Desander) and Accumulation Chamber for Separation of Solids from Produced Water
Hank Rawlins, PhD, P.E., eProcess Technologies, Technical Director; and Jesse Costin, Montana Tech of theUniversity of Montana
© 2013 eProcess Technologies.
Presented at the 2014 Produced Water Society annual seminar, January 14-16, Houston, TX.
AbstractThe flooded core solid-liquid hydrocyclone, termed a desander, is used extensively in the oil and gas industry to separatesand and solids from produced water. A desander comprises a standard solid-liquid hydrocyclone with an accumulation
chamber connected to the apex. The accumulation chamber prevents formation of an air core. Thus, the hydrocyclone
operates fully flooded. Solids collect in the accumulator for intermittent removal, while the overflow is continuallydischarged. In this manner the desander operates as a separation, and not a classification, device. With a flooded core and
static volume of water in the accumulator, the sand particle trajectory from inlet to apex is modified compared to the standard
open underflow hydrocyclone classifier. This project investigated the desander performance and the interaction between the
hydrocyclone and accumulator with emphasis on particle travel. Laboratory testing of a desander and hydrocyclone of
identical geometry showed no difference in hydraulic capacity and the same measured cut size (D50
). Settling of solids to the
accumulator does not follow a Stokes Law relationship, and the measured apex flux rate limits the inlet solids concentration
to ~2000 ppmw at normal conditions for small diameter desanders.
Produced Water Solids RemovalSand and solids are present in produced water in all production systems (Rawlins, 2013a). Sand reports to the production
system from producing wells, whereupon it settles in the low velocity zones of separator and free water knock out (FWKO)
vessels. Sand that fills these vessels is commonly removed by jetting or manual cleaning operations. Intermediate size sand,typically 25-200 microns in diameter, may flow with the water phase to exit the production separators (Rawlins, 2013b).
Small solids <25 microns generally collect in the oil phase or at the rag layer where they form part of the basic sediment &
water (BS&W) in the oil product. Large solids >200 microns tend to collect and fill the separating vessels. These
intermediate solids that discharge with the water phase will interfere with produced water treatment by eroding control
valves, plugging and eroding deoiling hydrocyclones, filling flotation cells, plugging media and cartridge filters, contributingto oil-in-water values (due to oil coating), or interfering with water injection systems. Desanding hydrocyclones, shown in
Figure 1, are the most common method for primary intermediate solids removal from produced water systems.
Figure 1. Process flow schematic of well fluid separation system with emphasis on produced water treatment. Dashed encircledarea shows location of desanding hydrocylones (desander) used to remove sand and solids prior to oil removal. Typical producedwater desander handles 100-500 ppmw so lids at 25-200 micron parti cle size.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 2/10
~ 2 ~
Desanding hydrocyclones, also called desanders, are located directly on the water outlet of a three phase separator or
FWKO. They should be located upstream of deoiling hydrocyclones and the liquid level control valve (Ditria and Hoyack,1994). The produced water at this point will generally have a sand concentration of <100 ppmw. The solids particle size will
range from 25-200 microns, with 125 microns as the common mean. Desanders operate using the inherent pressure in the
produced water stream and will require 10-30 psi of differential pressure. They are a static device with no moving parts and
have replaceable wear components. Locating the desander as the primary treatment on the produced water stream will protectall downstream components and will have no negative effect on subsequent oil removal from produced water.
Desander and AccumulatorDesanders are a cyclonic device, which is a common unit process in the upstream oil and gas industry. Cyclones are used forgas-liquid separation (separator internals, gas scrubbing, and compact separators), liquid-liquid separation (deoiling
hydrocyclones), and solid-fluid separation (wellhead desanders and produced water desanders). Cyclonic technology uses
pressure differential to drive the phase separation and relies on the geometric shape of the unit to create the desired flow
pattern. Cyclonic technology has the highest throughput-to-size ratio of any separating device (Rawlins and Wang, 2000).For a given flow rate it will have the smallest footprint and weight of any technology, which is an advantage in offshore and
subsea systems. In addition, cyclonic devices are unaffected by facility motion (necessary on floating systems) or orientation.
Due to the vortex flow pattern, a cyclonic device will generate between 100 and 5,000 times the acceleration due to gravity
(g-forces) pending the diameter and pressure drop.Desanding hydrocyclones are designed specifically for solids removal from a liquid stream. Two styles of desanders
have found use in the upstream petroleum industry. Figure 2 shows the single cone versus the multi-cone style. Both styles
are made from a pressure vessel housing containing one or more cyclonic inserts or lines. The insert style has a single
cyclonic replaceable insert while the multi-cone has multiple cyclonic liners operating in parallel. The insert and liner areeach replaceable within the vessel and are designed to provide the cyclonic separation flow pattern and contain the solidserosion. The pressure vessel contains the operating conditions but sees no erosive flow. Both styles have an inlet connection,
clean water fluids outlet, and integral accumulation chamber (accumulator) for collection and periodic discharge of the
separated solids.
Insert Style (Single Cone) Liner Style (Multi-Cone) One insert per vessel Many liners per vessel
Multiphase flow Liquid only flow
Smaller diameter vessel Larger diameter vessel
Change insert size for turndown >3:1 Change qty. of liners for turndown >3:1
No fluid partitioning Unequal multiphase fluid partitioning
Can treat particles 1”-2” diameter Can treat particles 0.1”-0.2” diameter
Inlet solids concentration to 5 wt.% or higher Inlet solids concentration to 0.25 wt.%
Figure 2. Cross section schematics of two styles of desanding vessels – insert st yle (left) and li ner style (right). The table below thedrawings l ists the attributes and operating r ange for each style.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 3/10
~ 3 ~
Figure 2 lists the attributes and operating range for each style of desander. The primary operating difference is how the
incoming fluids are treated. For the single cone, all fluids are contained within the one cyclonic insert. Incoming fluids to themulti-cone style are dispersed within the inlet chamber and have to distribute to each individual cyclonic liner. In using a
desander for multiphase applications (i.e., wellhead desander), the multi-cone style does not distribute the gas and liquid
phases equally to each liner. Therefore, variable performance can be exhibited. The single cone style treats multiphase fluid
in one device without gas-liquid portioning and provides higher separation efficiency. The insert style is used for multiphasedesanding, whereas the multi-cone style is preferred for liquid-only desanding.
One of the features of cyclonic devices is that as the diameter decreases, so does the separating size. For a liquid-only
application, a separation size of 10 microns is exhibited with a 1.5” diameter cyclone, whereas a 3” and 10” cyclone will have
a 30 micron and 60 micron separation size respectively. Multi-cone desanders are preferred for liquid-only applications dueto the higher solids removal efficiency. Single cone desanders work well in multiphase flow where the incoming fluid is a
mixture of gas and liquid. Thus, the continuous phase fluid has low viscosity and density, and particles are easy to remove. A
10” insert desander in 95% gas void fraction (GVF) stream can achieve a separation size of less than 10 microns.
Multi-cone desanders have higher solids removal efficiency in liquid applications; however, they are limited in the particle size they can treat without plugging. The liners in a multi-cone application may have a 0.25”-0.5” critical orifice
diameter (either inlet width or apex diameter), and particles exceeding this size will plug the liner units, which requires
removal of the liner to remove the blockage. Insert style desanders accommodate particles up to 1”-2” in diameter. These size
particles are not commonly seen in produced water streams, but are present in raw well flow. Hence, single cone desandersare used in wellhead applications.
Desanders were originally developed for treating water well flow in agricultural regions to prevent sand particles from
plugging irrigation nozzles. These applications had low concentrations of sand (<10 ppmw). Desanders were then introduced
to the upstream oil industry in the 1960s for produced water treatment, and the concentration of sand exhibited was muchhigher than envisioned from the agricultural units. A general rule of thumb for the maximum inlet solids concentration adesander could handle was one percent by volume. This value worked sufficiently in large diameter desanders, but as the
liner style desanders became more prevalent and the cyclonic diameters decreased to 3”, 2”, and 1”, the 1% value showed
problems of plugging and premature wear failure in many applications. A more accurate maximum value was required,especially a method that could be used across a range of operating conditions and cyclone diameters. The present work was
undertaken to measure the maximum inlet concentration small diameter cyclones could treat and determine a sizing method
to apply to the range of desander diameters.
Operation of Flooded Core HydrocyclonesThe solid-liquid hydrocyclone was developed in the 1890s and finds primary use in the mineral processing industry. Grinding
of ore to liberate valuable minerals uses banks of hydrocyclones (typically 10”-40” in diameter) as a classifying device in
closed-circuit arrangement. These hydrocyclones are operated at low pressure (inlet <30 psi) with open underflow and
overflow discharge (e.g., atmospheric pressure) and process slurry streams with 20-40 wt.% solids. The underflow fractioncontaining coarse solids is returned to the mill inlet for further grinding, while the overflow stream contains the fine solids
fraction that is sent to downstream processing (typically for flotation or further attrition). The key aspect in comparing a
mining or open underflow hydrocyclone to a desander is the treatment of the underflow stream, as illustrated in Figure 3.
Figure 3. Schematic of single-cone desander showing solid-fluid volume swapping that occurs as particles discharge through theapex and enter the accumulation chamber.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 4/10
~ 4 ~
A mineral hydrocyclone has an open underflow stream discharging at atmospheric pressure. The concentrated dischargeslurry discharges continuously and collects into an open launder or trough. A desander has a fully enclosed underflow stream
where the solids are collected into an accumulator chamber that fully encapsulates the underflow orifice, and solids are
discharged intermittently from the system. The solids in a desander are concentrated as they spin down the length of the cone
and exit the apex into the accumulation chamber. The accumulation chamber is a static body of water and the solids exitingthe apex displace the accumulator water, which then has to return through the apex into the cyclone body to eventually
discharge through the overflow. This effect is illustrated in the circled area of Figure 3.
The volume of solids (sand) entering the accumulation chamber displaces an equal volume of water back through the
apex, which can be termed volume-swapping (Rawlins, 2002). Volume-swapping occurs due to density differential betweenthe solids and water. While the particle “falls” into the accumulator, the downward trajectory of the particle is slightly
opposed by the upward flow of the water, which reduces the net terminal velocity. At low solids concentrations the terminal
velocity reduction is negligible; however, as the concentration of solids discharging the apex increases, the amount of liquid
returning will eventually choke the downward solids flow. Therefore, a maximum flux exists at which the desander canoperate. Above the flux limit, solids will start to aggregate at the apex entrance and back up into the cone section. This effect
is illustrated in Figure 4. As the solids level rises in the cone section, eventually the cyclonic body becomes full and the solids
will report to the vortex finder, resulting in degradation of separation performance. Laboratory investigation has shown that
filling of the cyclonic body in 2” diameter desanders can happen in a few minutes.
Figure 4. Two inch clear hydrocyclone configured as a desander with large accumulator vessel. The unit is operating at 20 psipressure drop and processing 12/20 mesh coal particles. The particles have exceeded the apex flux limit and are collecting in thelower cone section. Eventually the level of solids w ill ri se to the vortex finder, resulting in degradation of separation performance.
Another effect of aggregated solids collecting above a choked apex is premature erosive failure in the cone section of the
cyclonic component. A high velocity spinning fluidized bed of solids exists above the apex choke point. This concentrated
rotating fluidized bed generally erodes the middle section of the cone as shown in Figure 5. The 1.5” diameter desander in
this photo experienced premature failure in the cone section due to choking of the apex. The solids trapped in the cone
section were too heavy to report to the overflow, but were unable to quickly pass through the apex into the accumulator.
These spinning solids eroded the cone section until the wall was breached.
Desander Inlet
Cone Section
Apex
Accumulator (top plate)Solids falling into
Accumulator
Solids choked at
apex
Solids rising into
cone section
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 5/10
~ 5 ~
Figure 5. Erosion pattern marks on a 1.5” diameter desander showing premature failure in the cone section due to choked apex.Solids trajectory i s from left to ri ght. The cone section (left) shows severe wear while the apex (right) shows li ttle or no erosion .
Studies on Flooded Core HydrocyclonesOperating a standard hydrocyclone with open underflow results in a central air-core that exists throughout the full length of
the cyclonic body (from apex to vortex finder) and has a slight negative pressure (Svarovsky, 1984). Encapsulating the apexorifice floods the cyclonic body and prevents the formation of an air-core. The majority of scientific literature on
hydrocyclone operation and modeling pertains to open-underflow design containing an air-core (Plitt, 1984). A few studies
have been conducted with a flooded-core, solid-liquid hydrocyclone; however, none of these were conducted with a static
accumulation chamber. Researchers at McMaster University studied the velocity distribution in a 3” glass hydrocycloneoperating without an air core (Knowles et al., 1973). They connected the underflow to a pipe network that encapsulated the
apex. However, the system was operated by continuously pulling fluid away from the underflow, and thus preventing a static
fluid chamber. The operating conditions were set such that the underflow and overflow streams had similar flow rates. Only
velocity profiles were measured using tracer particles and high-speed photography, and the tangential, vertical, and radial
profiles were similar to an open underflow hydrocyclone. The tangential velocities were found to be less than half comparedto operation with an air-core. Further research was conducted with the same setup, but varied the underflow/overflow split
and measured classification performance (Witbeck and Woods, 1984). Their results showed a less sharp (flatter)classification curve with the flooded hydrocyclone and a pressure drop of 4-7 times compared to open underflow (note: thecurrent body of work showed negligible difference in pressure drop when comparing open and flooded underflow).
Researchers at Northeast University of Technology (Shenyang) measured performance of 2” and 3” water-sealed
hydrocyclones (Quian et al., 1989). Similar to the McMaster work, they withdrew a liquid stream from the underflow
chamber, which negated a static bed of water. When compared to open underflow performance, they measured slightly
greater solids recovery and a 1.6 times increase in pressure drop. When enclosing the underflow stream, they increased theapex diameter by 10 times to minimize blockage potential. All of these studies removed the air core by encapsulating the
underflow stream; however, they negated the development of a static bed by withdrawing fluid continuously away from the
accumulation chamber.
Experimental Flow LoopThe primary goal of this research was to determine the maximum flux rate, as a function of inlet stream solids concentration,
which a desander could process. To study the interaction of a flooded core hydrocyclone (desander) and static accumulationchamber during separation of solids from water, an experimental flow loop was built. Figure 6 shows a photograph of the test
loop with primary components identified. A 60 gallon cone bottom tank was used to house the inlet stream. Solids wereadded to the tank via a vibratory feeder and the slurry was prepared using a pneumatic tank mixer. Inlet concentrations to 100
ppmw accuracy were able to be prepared. The feed stream was delivered at the desired pressure/flow using a centrifugal
pump with variable frequency drive. Inlet pressure to the test hydrocyclone/desander was measured using a pressure indicator(0-30 psig). Overflow from the hydrocyclone/desander was returned at atmospheric pressure to the mixing tank, making a
closed-circuit test loop. The test cyclonic device consisted of a 2” diameter clear urethane (commercial) hydrocyclone
connected to a 2” clear cylindrical accumulation chamber (24” length with 10 ml gradation marks). The hydrocyclone had a
0.25 in2 inlet area, 0.8 inch diameter vortex finder, and 0.625 inch diameter apex.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 6/10
~ 6 ~
Figure 6. Experimental flow loop setup for testing hydrocyclone/desander apex flux rate. The loop consists of 60 gallon cone-tankwith mixer, centrifugal feed pump, and 2” clear hydrocyclone with graduated accumulator.
The test slurry consisted of municipal water (1.007 s.g. and 1.014 cP at 15°C) mixed with SiO2 test sand. Most of the
tests used silica sand with a 2.66 s.g. and particle size from 38-600 µm in diameter. The <38µm fraction was removed by wet
sieve. For tests using finer sand, a monocrystalline silica was used with a P50 of 12 µm and 95% passing 45 µm. This material
had a 2.66 s.g. as well. The coarse sand had a packing void fraction of 47.3%, while the fine sand had a value of 44.4%.Densities were measured using immersion pycnometry, void fraction by volumetric analysis, and viscosity by capillary
viscometer.In preparation for the test work, a hypothetical model was developed based on the following premises:
• All solids entering the hydrocyclone report to the apex (i.e., the solids used in testing were large enough to represent
100% recovery). This premise was necessary to test a simple mass balance inlet concentration measured without
subtraction of particles reporting to the overflow.
• Particles entering the hydrocyclone travel in a standard vortex pattern from the inlet to the apex.
• Upon reaching the apex, particle motion and velocity are fully arrested because the liquid in the accumulator isstatic.
• The particles fall through the static liquid in the accumulator as approximated by Stokes’ Law. Based on this
premise, the apex threshold concentration should be a function of particle size, solid-fluid density, and liquidviscosity.
• For every volume of particle that enters the accumulator, an equivalent volume of liquid returns upward through the
apex to eventually exit with the hydrocyclone overflow stream.
•
The apex represents a choke point in the downward flow of particles from the hydrocyclone to the accumulator. Assuch, once the choke value (or apex threshold) is reached, the rate at which the particles fall from the choked apex
should remain constant. Further increase in inlet concentration would result in continued deterioration ofhydrocyclone separation efficiency, as defined by mass balance, because more particles cannot be pushed through
the choked apex and will then report to the overflow stream.
• A model was constructed to provide a first-order estimate of the target concentration.The general test procedure first used the theoretical inlet concentration based on the target particle size range. A particle
size range (i.e., 106-212 µm) was used in each test with the geometric average used as the indicative size. This value was
used to set the vibratory feeder rate (g/min), which would provide the desired inlet concentration in ppmw. Flow was
established through the loop such that the desander exhibited a 20 psi pressure drop (~22 gpm). The vibratory feeder and tank
mixer were started along with test time. Slurry was formed in the tank and allowed to reach steady-state through the loop.Solids fed through the hydrocyclone inlet and traveled in a vortex pattern to the apex. Visual confirmation was used to
confirm steady-state particle travel, as shown in Figure 7.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 7/10
~ 7 ~
Figure 7. Photographs showing (left to right) particle travel through hydrocyclone cone section to accumulator, particles settlingand settled in accumulator, onset of apex plugging, and advanced plugging where solids begin to fill up hydrocyclone body.
The time to fill two 400 ml sections of the accumulator was recorded. In addition, visual assessment of the solids level at
the cone-apex interface was recorded. If hydrocyclone appeared to be filling at seven minutes (Figure 7 right), the test was
allowed to run at least three more minutes before it was shut down. The inlet concentration was deemed above the apex
threshold. If the hydrocyclone was not filled by 10 minutes, the test was completed and the inlet concentration was deemed below the threshold. If the test conditions were below apex threshold, the concentration was increased for the next run or vice
versa if the conditions were above apex threshold. At the end of each test, the collected solids were dried and weighed. An
iterative approach was taken until the apex threshold was bracketed by 100 ppmw concentration. For example, at 106-212
particle size range, 2600 ppmw inlet concentration was below the apex threshold while 2700 ppmw inlet concentration wasabove the apex threshold. Therefore, the apex threshold was set at the average concentration of 2650 ppmw.
Apex Solids ThresholdData for apex solids threshold at five particle size range averages is shown in Figure 8. The geometric average for each
particle size range was used as the mean size listed on the abscissa. The ordinate axis lists the inlet solids concentration
(ppmw) required to reach the apex threshold. The actual data curve shows the limiting line of operation below which the
desander operates with steady-state transfer of solids from the cyclone through the apex to the accumulator. Above this curve
the hydrocyclone body will fill with solids due to apex choking, and the rate of filling is proportional to the distance operatedabove this curve. The particles shown on the curve have the same mineralogy and specific gravity at all particle sizes.
Also shown in Figure 8 is the first-order particle transfer model based on Stokes’ settling theory. This line is based on
the premise that the average particle size settles unhindered to terminal velocity based on Stokes’ Law. Stokes shows the
settling velocity proportional to the square of the particle size; therefore, larger particles will fall through the apex faster,which results in higher inlet concentrations allowed at the desander inlet. The actual data has nearly an inverse square
relationship between particle size and inlet concentration showing impediment during settling. This reduction in velocity is
due to both the upward flow of liquid from the accumulator through the cone section and crowding of the particles at the apex
resulting in packed, not free, flow. A second order model encompassing these parameters is being developed to moreaccurately scale this effect based on mechanistic principles.
Part of the test program measured the rate of solids collection in the accumulator using the 10 ml graduation marks. The
collection rate (ml/s converted to g/s using packing void fraction and density) was determined prior to, during, and after
reaching the apex threshold rate. Figure 9 shows the results for sand in the 106-212 µm size range. The x axis lists the percentof apex threshold rate, which had been previously determined for this sand size range. The y axis lists the apex flux rate in
g/s. The apex flux rate steadily increases to a maximum of 3.3 g/s at 100% threshold rate, then slightly declines to a near
steady 3.0 g/s above the threshold. Solids are passing through the apex at all inlet concentration levels, but the flux rate
through the apex reaches a maximum point (3.0 g/s in this case). Above this flux rate, the solids will start to fill the cone
section. The maximum apex flux rate can be used to determine the maximum allowable inlet concentration for operation
without filling the cyclone body.
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 8/10
~ 8 ~
Figure 8. Comparison of Stokes’ Law based settling model versus actual data from apex solids threshold testi ng.
Figure 9. Apex flux rate as a function of percent of threshold rate. After reaching a functional threshold, the flux rate settles to aconstant value.
The maximum flux rate at 100% apex threshold was determined for a range of sand particle sizes and this data was usedto generate a series of curves for first-order (approximation) scaling to other desander sizes. Figure 10 shows the mean
particle size versus inlet threshold concentration (ppmw) for 2”-8” desanders. The desanders are scaled up using common
cyclonic geometry ratio (Dapex~0.3Dcylinder ). For example, a 3” desander separating sand from water with 125 µm mean particle size has a limiting inlet value of ~2000 ppmw at the inlet stream before the apex is choked due to overcrowding. An
8” desander has a limiting value of nearly three times that rate (~6000 ppmw). These curves provide a more accurate
guideline than the 1% (10,000 ppm) rule of thumb commonly used. They also show that small diameter desanders should not
be used in high solids concentration applications like treating sand jet slurry or during well flow back operations.
0
2000
4000
6000
8000
10000
12000
14000
16000
0 50 100 150 200 250 300 350 400
I n l e t C o n c e n t r a t i o n t o R e a c h
T h r e s h o l d ( p p m w )
Mean Particle Size (µm)
Stokes Model
Actual Data (20 psi)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
50 75 100 125 150
A p e x
F l u x R a t e ( g / s )
% of Apex Threshold Rate
2.65 s.g. sand
106‐212 µm
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 9/10
~ 9 ~
Figure 10. Curves showing inlet con centration at which apex threshold is reached for various diameter desanders. Values based onsand in fresh w ater.
Apex Flux Balancing
The curves in Figure 10 show the limiting inlet concentration that a specific size desander can operate before apex chokingoccurs. This data is generated and modeled for a static accumulator in which the liquid is displaced up by the downward
falling particles. Modifying the system design to allow the liquid in the accumulator to exit the contained volume in a mannerother than upward through the apex will increase the downward flux of particle, thus enabling operation of a desander with a
much higher inlet concentration. An apex flux balance line is installed from the accumulator chamber to an external location
with lower pressure. The outward liquid flow is controlled and the minimum amount should be equal to the volume rate of
solids entering from the apex. The liquid is removed at the same rate as the solids are coming in. This method, called ApexFlux Balancing (AFB), can be used to overcome the threshold induced by a static accumulator. Figure 11 illustrates a flow
schematic for a single cone desander with an AFB line installed.
Figure 11. Flow schematic of single cone desander with apex flux balance line inst alled. Connection i s made to the desander vesselbody, above the apex, to the overflow stream. A manual control valve and flow ind icator are used to balance the liquid removal ratewith incoming solids collection rate.
The flux line inlet is connected to the desander vessel body and the take-off point is above the insert apex (which createsa tortuous path and prevents solids from being pulled into the balance line flow). The outlet of the balance line is connected
to the overflow stream in this case, which provides a manageable lower pressure connection point. The flow through this line
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
0 50 100 150 200 250 300 350 400
I n l e t T h r e s h o l d C o
n c e n t r a t i o n ( p p m w )
Particle Mean Size (microns)
2" Desander
3" Desander
4" Desander
6" Desander
8" Desander
Sand Density: 2.65 g/cm³
Pressure Drop: 20 psi
Water: 1.0 g/cm³, 1.0 cP
8/10/2019 PWS2014 Rawlins DesanderStudyR
http://slidepdf.com/reader/full/pws2014-rawlins-desanderstudyr 10/10