Metroll Newcastle ABN 97 001 446 439 268 Macquarie Road WARNERS BAY NSW 2282 AUSTRALIA P: +61 (0)2 4954 5799 F: +61 (0)2 4954 0891 [email protected] www.metrollnewcastle.com.au 1 PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method 2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa 3. The loads have been based on the use of approved Metroll sections & bridging systems. 4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal). 5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150 Overall purlin length = span + 70mm + lap/2 Span (mm) Span (mm) Lap Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m) SECTION 10010 LOADING Inward Outward Def BRIDGING 0,1,2,3 0 1 2 3 2100 2400 2700 3000 3300 3600 3900 4200 4500 4800 5100 5400 5700 5.32 4.07 3.22 2.61 2.15 1.81 1.54 1.33 1.16 1.02 0.90 0.80 0.72 5.32 4.07 3.22 2.61 2.15 1.81 1.54 1.33 1.16 1.02 0.90 0.80 0.72 5.32 4.07 3.22 2.61 2.15 1.81 1.54 1.33 1.16 1.02 0.90 0.80 0.72 5.32 4.07 3.22 2.61 2.15 1.81 1.54 1.33 1.16 1.02 0.90 0.80 0.72 5.32 4.07 3.22 2.61 2.15 1.81 1.54 1.33 1.16 1.02 0.90 0.80 0.72 11.83 7.92 5.57 4.06 3.05 2.35 1.85 1.48 1.20 0.99 0.83 0.70 0.59 Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m) SECTION 10012 LOADING Inward Outward Def BRIDGING 0,1,2,3 0 1 2 3 2100 2400 2700 3000 3300 3600 3900 4200 4500 4800 5100 5400 5700 6000 6300 6600 6.09 4.66 3.69 2.99 2.47 2.07 1.77 1.52 1.33 1.17 1.03 0.92 0.83 0.75 0.68 0.62 6.02 4.61 3.64 2.95 2.44 2.05 1.75 1.51 1.31 1.15 1.02 0.91 0.82 0.74 0.67 0.61 6.09 4.66 3.69 2.99 2.47 2.07 1.77 1.52 1.33 1.17 1.03 0.92 0.83 0.75 0.68 0.62 6.09 4.66 3.69 2.99 2.47 2.07 1.77 1.52 1.33 1.17 1.03 0.92 0.83 0.75 0.68 0.62 6.09 4.66 3.69 2.99 2.47 2.07 1.77 1.52 1.33 1.17 1.03 0.92 0.83 0.75 0.68 0.62 14.78 9.90 6.95 5.07 3.81 2.93 2.31 1.85 1.50 1.24 1.03 0.87 0.74 0.63 0.55 0.48

Transcript of PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped...

Page 1: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 1

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m)

SECTION 10010

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

2100240027003000330036003900420045004800510054005700

5.324.073.222.612.151.811.541.331.161.020.900.800.72

5.324.073.222.612.151.811.541.331.161.020.900.800.72

5.324.073.222.612.151.811.541.331.161.020.900.800.72

5.324.073.222.612.151.811.541.331.161.020.900.800.72

5.324.073.222.612.151.811.541.331.161.020.900.800.72

11.837.925.574.063.052.351.851.481.200.990.830.700.59

Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m)

SECTION 10012

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

2100240027003000330036003900420045004800510054005700600063006600

6.094.663.692.992.472.071.771.521.331.171.030.920.830.750.680.62

6.024.613.642.952.442.051.751.511.311.151.020.910.820.740.670.61

6.094.663.692.992.472.071.771.521.331.171.030.920.830.750.680.62

6.094.663.692.992.472.071.771.521.331.171.030.920.830.750.680.62

6.094.663.692.992.472.071.771.521.331.171.030.920.830.750.680.62

14.789.906.955.073.812.932.311.851.501.241.030.870.740.630.550.48

Page 2: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 2

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m)

SECTION 10015

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

2100240027003000330036003900420045004800510054005700600063006600690072007500

8.156.244.933.993.302.772.362.041.771.561.381.231.111.000.910.820.750.690.64

7.345.624.443.602.972.502.131.841.601.411.241.111.000.900.820.740.680.620.58

8.156.244.933.993.302.772.362.041.771.561.381.231.111.000.910.820.750.690.64

8.156.244.933.993.302.772.362.041.771.561.381.231.111.000.910.820.750.690.64

8.156.244.933.993.302.772.362.041.771.561.381.231.111.000.910.820.750.690.64

18.8512.638.876.474.863.742.942.361.921.581.321.110.940.810.700.610.530.470.41

Table DL100-Double Spans(Lapped) for Z100 Sections - Limit state capacity (kN/m)

SECTION 10019

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

2700300033003600390042004500480051005400570060006300660069007200750078008100840087009000

6.305.114.223.553.022.612.271.991.771.581.411.281.161.060.970.890.820.760.700.650.610.57

5.564.513.723.132.672.302.001.761.561.391.251.131.020.930.850.780.720.670.620.570.540.50

6.305.114.223.553.022.612.271.991.771.581.411.281.161.060.970.890.820.760.700.650.610.57

7.055.714.723.963.382.912.542.231.981.761.581.431.291.181.080.990.910.840.780.730.680.63

7.055.714.723.963.382.912.542.231.981.761.581.431.291.181.080.990.910.840.780.730.680.63

11.118.106.094.693.692.952.401.981.651.391.181.010.870.760.670.590.520.460.410.370.330.30

Page 3: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 3

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL150-Double Spans(Lapped) for Z150 Sections - Limit state capacity (kN/m)

SECTION 15019

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

300033003600390042004500480051005400570060006300660069007200750078008100840087009000

10.308.527.166.105.264.584.023.573.182.852.582.342.131.951.791.651.521.411.311.231.14

9.097.516.315.384.644.043.553.152.812.522.272.061.881.721.581.451.341.251.161.081.01

10.308.527.166.105.264.584.023.573.182.852.582.342.131.951.791.651.521.411.311.231.14

10.418.617.236.165.314.634.073.603.212.882.602.362.151.971.811.671.541.431.331.241.16

10.418.617.236.165.314.634.073.603.212.882.602.362.151.971.811.671.541.431.331.241.16

24.2418.2114.0311.038.837.185.924.934.163.533.032.622.281.991.751.551.381.231.100.990.90

Page 4: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 4

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL150-Double Spans(Lapped) for Z150 Sections - Limit state capacity (kN/m)

SECTION 15024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

300033003600390042004500480051005400570060006300660069007200750078008100840087009000930096009900

10200105001080011100114001170012000

12.8710.648.947.626.575.725.034.453.973.573.222.922.662.432.232.061.901.771.641.531.431.341.261.181.111.050.990.940.890.850.80

11.369.397.896.725.795.054.443.933.513.152.842.582.352.151.971.821.681.561.451.351.261.181.111.040.980.930.880.830.790.750.71

12.8710.648.947.626.575.725.034.453.973.573.222.922.662.432.232.061.901.771.641.531.431.341.261.181.111.050.990.940.890.850.80

14.3911.899.998.517.346.395.624.984.443.983.603.262.972.722.502.302.131.971.831.711.601.501.401.321.241.171.111.051.000.950.90

14.3911.899.998.517.346.395.624.984.443.983.603.262.972.722.502.302.131.971.831.711.601.501.401.321.241.171.111.051.000.950.90

30.4722.8917.6313.8711.109.037.446.205.224.443.813.292.862.502.201.951.731.551.391.251.131.020.930.850.780.710.650.600.560.510.48

Page 5: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 5

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL200-Double Spans(Lapped) for Z200 Sections - Limit state capacity (kN/m)

SECTION 20015

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

300033003600390042004500480051005400570060006300660069007200750078008100840087009000930096009900

102001050010800102001050010800

8.907.646.425.474.714.113.613.202.852.562.312.101.911.751.601.481.371.271.181.101.030.960.900.850.800.750.710.640.610.57

8.907.645.945.064.363.803.342.962.642.372.141.941.771.621.481.371.261.171.091.020.950.890.840.790.740.700.660.640.610.57

8.907.646.425.474.714.113.613.202.852.562.312.101.911.751.601.481.371.271.181.101.030.960.900.850.800.750.710.640.610.57

8.907.646.425.474.714.113.613.202.852.562.312.101.911.751.601.481.371.271.181.101.030.960.900.850.800.750.710.640.610.57

8.907.646.425.474.714.113.613.202.852.562.312.101.911.751.601.481.371.271.181.101.030.960.900.850.800.750.710.640.610.57

39.6129.7622.9218.0314.4411.749.678.066.795.784.954.283.723.262.872.542.252.011.801.621.471.331.211.101.010.920.851.010.920.85

Page 6: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 6

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL200-Double Spans(Lapped) for Z200 Sections - Limit state capacity (kN/m)

SECTION 20019

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

300033003600390042004500480051005400570060006300660069007200750078008100840087009000930096009900

10200105001080011100114001170012000

14.0111.579.738.297.156.225.474.854.323.883.503.182.892.652.432.242.071.921.791.671.561.461.371.291.211.141.081.020.970.920.88

11.719.688.136.935.975.204.574.053.613.242.932.662.422.212.031.871.731.611.491.391.301.221.141.081.010.960.900.860.810.770.73

13.6611.299.498.086.976.075.344.734.223.783.423.102.822.582.372.192.021.871.741.621.521.421.331.251.181.121.051.000.950.900.85

14.0111.579.738.297.156.225.474.854.323.883.503.182.892.652.432.242.071.921.791.671.561.461.371.291.211.141.081.020.970.920.88

14.0111.579.738.297.156.225.474.854.323.883.503.182.892.652.432.242.071.921.791.671.561.461.371.291.211.141.081.020.970.920.88

52.9439.7830.6424.1019.2915.6912.9310.789.087.726.625.724.974.353.833.393.012.692.412.171.961.781.621.471.351.231.131.050.960.890.83

Page 7: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 7

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL200-Double Spans(Lapped) for Z200 Sections - Limit state capacity (kN/m)

SECTION 20024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

3600390042004500480051005400570060006300660069007200750078008100840087009000930096009900

10200105001080011100114001170012000

13.4611.479.898.617.576.715.985.374.854.394.003.663.363.102.872.662.472.302.152.021.891.781.681.581.501.421.341.271.21

10.699.117.856.846.015.324.754.263.853.493.182.912.672.462.282.111.961.831.711.601.501.411.331.261.191.121.071.010.96

12.4710.629.167.987.016.215.544.974.494.073.713.393.122.872.662.462.292.131.991.871.751.651.551.471.391.311.241.181.12

13.4611.479.898.617.576.715.985.374.854.394.003.663.363.102.872.662.472.302.152.021.891.781.681.581.501.421.341.271.21

13.4611.479.898.617.576.715.985.374.854.394.003.663.363.102.872.662.472.302.152.021.891.781.681.581.501.421.341.271.21

39.7231.2425.0220.3416.7613.9711.7710.018.587.416.455.644.974.393.913.493.132.812.542.302.091.911.751.601.471.361.251.161.07

Page 8: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 8

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL250-Double Spans(Lapped) for Z250 Sections - Limit state capacity (kN/m)

SECTION 25019

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

3600390042004500480051005400570060006300660069007200750078008100840087009000930096009900

10200105001080011100114001170012000

11.349.668.337.266.385.655.044.524.083.703.373.092.832.612.422.242.081.941.811.701.591.501.411.331.261.191.131.071.02

11.039.408.107.066.205.504.904.403.973.603.283.002.762.542.352.182.031.891.761.651.551.461.371.301.231.161.101.040.99

11.349.668.337.266.385.655.044.524.083.703.373.092.832.612.422.242.081.941.811.701.591.501.411.331.261.191.131.071.02

11.349.668.337.266.385.655.044.524.083.703.373.092.832.612.422.242.081.941.811.701.591.501.411.331.261.191.131.071.02

11.349.668.337.266.385.655.044.524.083.703.373.092.832.612.422.242.081.941.811.701.591.501.411.331.261.191.131.071.02

51.8240.7632.6326.5321.8618.2315.3513.0611.199.678.417.366.485.735.094.554.083.673.323.012.732.492.282.091.921.771.631.511.40

Page 9: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 9

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL250-Double Spans(Lapped) for Z250 Sections - Limit state capacity (kN/m)

SECTION 25024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

4500480051005400570060006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

11.109.768.657.716.926.255.675.164.724.344.003.703.433.192.972.782.602.442.292.162.041.931.821.731.641.561.491.421.351.291.231.181.131.081.041.000.960.920.890.860.830.800.770.740.720.69

9.268.147.216.435.775.214.734.313.943.623.333.082.862.662.482.322.172.041.911.801.701.611.521.441.371.301.241.181.131.081.030.990.940.900.870.830.800.770.740.710.690.660.640.620.600.58

10.819.508.417.516.746.085.515.024.604.223.893.603.343.102.892.702.532.372.232.101.991.881.781.681.601.521.451.381.321.261.201.151.101.061.010.970.930.900.870.830.800.780.750.720.700.68

11.109.768.657.716.926.255.675.164.724.344.003.703.433.192.972.782.602.442.292.162.041.931.821.731.641.561.491.421.351.291.231.181.131.081.041.000.960.920.890.860.830.800.770.740.720.69

11.109.768.657.716.926.255.675.164.724.344.003.703.433.192.972.782.602.442.292.162.041.931.821.731.641.561.491.421.351.291.231.181.131.081.041.000.960.920.890.860.830.800.770.740.720.69

34.4128.3523.6419.9116.9314.5212.5410.919.548.407.436.615.905.294.764.303.903.543.232.952.712.492.292.121.961.811.681.571.461.361.271.191.121.050.990.930.880.830.780.740.700.660.630.600.570.54

Page 10: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 10

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL300-Double Spans(Lapped) for Z300 Sections - Limit state capacity (kN/m)

SECTION 30024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

60006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

8.447.666.986.385.865.405.004.634.314.023.753.513.303.102.922.762.612.472.342.222.112.011.911.831.741.671.601.531.471.411.351.301.251.201.161.121.081.041.000.970.94

7.426.736.135.615.154.754.394.073.793.533.303.092.902.732.572.422.292.172.061.951.861.771.681.611.531.471.401.341.291.241.191.141.101.061.020.980.950.910.880.850.82

8.447.666.986.385.865.405.004.634.314.023.753.513.303.102.922.762.612.472.342.222.112.011.911.831.741.671.601.531.471.411.351.301.251.201.161.121.081.041.000.970.94

8.447.666.986.385.865.405.004.634.314.023.753.513.303.102.922.762.612.472.342.222.112.011.911.831.741.671.601.531.471.411.351.301.251.201.161.121.081.041.000.970.94

8.447.666.986.385.865.405.004.634.314.023.753.513.303.102.922.762.612.472.342.222.112.011.911.831.741.671.601.531.471.411.351.301.251.201.161.121.081.041.000.970.94

24.8221.4418.6516.3214.3612.7111.3010.099.058.147.356.676.065.535.054.634.263.923.623.353.102.882.682.502.332.182.041.911.801.691.591.501.411.331.261.191.131.071.020.970.92

Page 11: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 11

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL300-Double Spans(Lapped) for Z300 Sections - Limit state capacity (kN/m)

SECTION 30030

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

60006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

12.2011.0710.099.238.487.817.226.706.235.805.425.084.774.484.223.993.773.573.383.213.052.902.772.642.522.412.312.212.122.031.951.881.811.741.671.611.561.501.451.401.36

9.788.878.087.396.796.265.785.364.994.654.344.073.823.593.383.193.022.862.712.572.442.332.222.112.021.931.851.771.701.631.561.501.451.391.341.291.251.201.161.121.09

11.4010.349.438.627.927.306.756.265.825.425.074.754.454.193.953.723.523.333.163.002.852.712.592.472.362.252.162.071.981.901.821.751.691.621.561.511.451.401.361.311.27

12.2011.0710.099.238.487.817.226.706.235.805.425.084.774.484.223.993.773.573.383.213.052.902.772.642.522.412.312.212.122.031.951.881.811.741.671.611.561.501.451.401.36

12.2011.0710.099.238.487.817.226.706.235.805.425.084.774.484.223.993.773.573.383.213.052.902.772.642.522.412.312.212.122.031.951.881.811.741.671.611.561.501.451.401.36

32.1427.7624.1421.1318.6016.4514.6313.0611.7110.549.528.637.857.156.546.005.515.084.694.334.023.733.473.233.022.822.642.482.322.192.061.941.831.731.631.551.461.391.321.251.19

Page 12: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 12

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL350-Double Spans(Lapped) for Z350 Sections - Limit state capacity (kN/m)

SECTION 35030

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

60006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

14.5213.1712.0010.9810.089.298.597.977.416.916.456.045.675.335.024.744.484.244.023.823.633.453.293.143.002.872.742.632.522.422.322.232.152.071.991.921.851.791.731.671.61

13.1111.8910.839.919.108.397.767.196.696.235.835.465.124.814.544.284.053.833.633.453.283.122.972.842.712.592.482.372.282.182.102.021.941.871.801.731.671.611.561.511.46

14.5213.1712.0010.9810.089.298.597.977.416.916.456.045.675.335.024.744.484.244.023.823.633.453.293.143.002.872.742.632.522.422.322.232.152.071.991.921.851.791.731.671.61

14.5213.1712.0010.9810.089.298.597.977.416.916.456.045.675.335.024.744.484.244.023.823.633.453.293.143.002.872.742.632.522.422.322.232.152.071.991.921.851.791.731.671.61

14.5213.1712.0010.9810.089.298.597.977.416.916.456.045.675.335.024.744.484.244.023.823.633.453.293.143.002.872.742.632.522.422.322.232.152.071.991.921.851.791.731.671.61

51.5644.5438.7333.9029.8426.4023.4720.9518.7916.9115.2813.8412.5911.4810.499.628.848.147.526.956.445.985.575.194.844.534.243.973.733.513.303.112.932.772.622.482.352.232.112.011.91

Page 13: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 13

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL350-Double Spans(Lapped) for Z350 Sections - Limit state capacity (kN/m)

SECTION 35024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

60006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

10.129.188.377.657.036.485.995.555.164.814.504.213.953.723.503.313.122.962.802.662.532.412.302.192.092.001.911.831.761.691.621.561.501.441.391.341.291.251.201.161.12

10.019.088.277.576.956.415.925.495.114.764.454.173.913.683.463.273.092.922.772.632.502.382.272.172.071.981.891.811.741.671.601.541.481.431.371.321.281.231.191.151.11

10.129.188.377.657.036.485.995.555.164.814.504.213.953.723.503.313.122.962.802.662.532.412.302.192.092.001.911.831.761.691.621.561.501.441.391.341.291.251.201.161.12

10.129.188.377.657.036.485.995.555.164.814.504.213.953.723.503.313.122.962.802.662.532.412.302.192.092.001.911.831.761.691.621.561.501.441.391.341.291.251.201.161.12

10.129.188.377.657.036.485.995.555.164.814.504.213.953.723.503.313.122.962.802.662.532.412.302.192.092.001.911.831.761.691.621.561.501.441.391.341.291.251.201.161.12

40.2534.7730.2426.4623.2920.6118.3216.3614.6713.2011.9310.819.838.968.197.516.906.365.875.435.034.674.354.053.783.533.313.102.912.742.582.432.292.162.041.941.831.741.651.571.49

Page 14: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 14

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL400-Double Spans(Lapped) for Z400 Sections - Limit state capacity (kN/m)

SECTION 40024

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

40.2534.7730.2426.4623.2920.6118.3216.3614.6713.2011.9310.819.838.968.197.516.906.365.875.435.034.674.354.053.783.533.313.102.912.742.582.432.292.162.041.941.831.741.651.571.49

11.2610.229.318.527.827.216.666.185.755.365.014.694.404.143.903.683.483.293.122.962.822.682.552.442.332.222.132.041.961.881.801.731.671.601.551.491.441.391.341.291.25

11.2610.229.318.527.827.216.666.185.755.365.014.694.404.143.903.683.483.293.122.962.822.682.552.442.332.222.132.041.961.881.801.731.671.601.551.491.441.391.341.291.25

11.2610.229.318.527.827.216.666.185.755.365.014.694.404.143.903.683.483.293.122.962.822.682.552.442.332.222.132.041.961.881.801.731.671.601.551.491.441.391.341.291.25

11.2610.229.318.527.827.216.666.185.755.365.014.694.404.143.903.683.483.293.122.962.822.682.552.442.332.222.132.041.961.881.801.731.671.601.551.491.441.391.341.291.25

11.2610.229.318.527.827.216.666.185.755.365.014.694.404.143.903.683.483.293.122.962.822.682.552.442.332.222.132.041.961.881.801.731.671.601.551.491.441.391.341.291.25

55.2447.7241.5036.3231.9728.2825.1422.4520.1318.1216.3714.8313.4912.3011.2410.319.478.728.057.456.916.415.965.565.194.854.544.264.003.763.543.333.142.972.812.662.522.392.272.152.05

Page 15: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 15

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table DL400-Double Spans(Lapped) for Z400 Sections - Limit state capacity (kN/m)

SECTION 40030

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

60006300660069007200750078008100840087009000930096009900

102001050010800111001140011700120001230012600129001320013500138001410014400147001500015300156001590016200165001680017100174001770018000

17.1515.5514.1712.9711.9110.9710.159.418.758.167.627.146.706.305.935.605.295.014.754.514.294.083.893.713.543.393.243.102.982.862.742.642.542.442.352.272.192.112.041.971.91

15.8814.4013.1212.0111.0310.169.408.718.107.557.066.616.205.835.495.194.904.644.404.183.973.783.603.443.283.143.002.882.762.652.542.442.352.262.182.102.031.951.891.821.76

17.1515.5514.1712.9711.9110.9710.159.418.758.167.627.146.706.305.935.605.295.014.754.514.294.083.893.713.543.393.243.102.982.862.742.642.542.442.352.272.192.112.041.971.91

17.1515.5514.1712.9711.9110.9710.159.418.758.167.627.146.706.305.935.605.295.014.754.514.294.083.893.713.543.393.243.102.982.862.742.642.542.442.352.272.192.112.041.971.91

17.1515.5514.1712.9711.9110.9710.159.418.758.167.627.146.706.305.935.605.295.014.754.514.294.083.893.713.543.393.243.102.982.862.742.642.542.442.352.272.192.112.041.971.91

71.1761.4853.4746.8041.1936.4432.3928.9325.9423.3421.0919.1117.3815.8414.4913.2812.2011.2410.389.608.908.267.687.166.686.255.855.485.154.844.554.294.053.823.623.423.243.072.922.772.64

Page 16: PURLINS & GIRTS - DOUBLE LAPPED SPAN€¦ · PURLINS & GIRTS - DOUBLE LAPPED SPAN Double Lapped Span NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit

Metroll NewcastleABN 97 001 446 439268 Macquarie Road WARNERS BAY NSW 2282AUSTRALIAP: +61 (0)2 4954 5799F: +61 (0)2 4954 [email protected] 16

PURLINS & GIRTS - DOUBLE LAPPED SPAN

Double Lapped Span

NOTES: 1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method

2. Following values of Fy considered for calculating the ultimate loads • 1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa • 1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa • 1.5, 1.9, 2.4, 3.0 mm BMT Grade AS1397/ G450 Z350 - Fy = 450 Mpa

3. The loads have been based on the use of approved Metroll sections & bridging systems.

4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds the normal delivery length (12000 mm nominal).

5. IN = Inward load capacity. OUT = outward load capacity. DEF. = Load required to give a deflection of SPAN/150

Overall purlin length = span + 70mm + lap/2

Span (mm) Span (mm)

Lap

Table F100-Four Spans for Z/C100 Sections - Limit state capacity (kN/m)

SECTION 10012

LOADING Inward Outward Def

BRIDGING 0,1,2,3 0 1 2 3

2100240027003000330036003900420045004800510054005700600063006600

4.843.712.932.371.961.651.401.211.050.930.820.730.660.590.540.49

4.843.712.932.371.961.651.401.211.050.930.820.730.660.590.54

4.843.712.932.371.961.651.401.211.050.930.820.730.660.590.540.49

4.843.712.932.371.961.651.401.211.050.930.820.730.660.590.540.49

4.843.712.932.371.961.651.401.211.050.930.820.730.660.590.540.49

8.735.854.112.992.251.731.361.090.890.730.610.510.440.370.320.28