Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13,...

21
Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012

Transcript of Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13,...

Page 1: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Marine Chemist Association

2012 National Seminar

Chicago, IL

August 13, 2012

Page 2: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

27 April 2001

Commandant Notice 16000

CONFINED SPACE ENTRY POLICY ABOARD MERCHANT VESSELS

FOR MARINE SAFETY AND

ENVIRONMENTAL PROTECTION PERSONNEL

Page 3: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Current guidance for confined space entry is in the form of recommended Safe Work Practices (SWP’s) contained in the Marine Safety Manual (MSM), Volume I, Chapter 10. Although much of the guidance in the MSM has been modified over the years and has been incorporated into SWP’s in the current version, the general policy of requiring an NFPA Certificated Marine Chemist to test and certify confined spaces prior to entry by Coast Guard personnel has not changed.

Page 4: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard IncidentCommandant Notice 16000

Who must certify confined spaces on

merchant vessels safe for entry by

Coast Guard personnel?

Page 5: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Commandant Notice 16000

A Certified Marine Chemist shall conduct the initial inspection and certify confined spaces on merchant vessels “Safe for Workers” before entry by Coast Guard personnel.

Page 6: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

February 17, 2011

M/T Wilana

Crude Oil Carrier

U S Coast Guard COC Inspection

Loop Anchorage

Pump Room Inspection

Page 7: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

February 17, 2011M/T Wilana Crude Oil CarrierCCR Fixed Gas Monitor Pump Room ReadingsO2 – 20.9%

LEL – 0%H2S – 0ppm

Page 8: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

February 17, 2011M/T Wilana Crude Oil CarrierRineken Portable Gas Monitor Pump Room ReadingsO2 – 20.9%LEL – 0%H2S – 0ppm CO- 0ppm

Page 9: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard IncidentFebruary 17, 2011M/T Wilana Crude Oil CarrierMSA Orion Portable Gas Monitor Pump Room Readingsat the bottom of the pump room

O2 – 20.8%LEL – 46%H2S – 0ppm CO- 0ppmToxirae PGM30THC - >2000ppm

Page 10: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

February 17, 2011M/T Wilana Crude Oil Carrier

Vacuum Assist Stripping System (VASS)

Automatic Stripping System (AUSS)

Page 11: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 12: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 13: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

After 1 hour additional ventilation with both ventilators:The pump room was retested and entry was authorized for the chemist and pumpie to enter and install a blind flange on the goose neck vent

Page 14: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

With both ventilators running, the atmosphere was cleared for U S Coast Guard personnelReadings were as follow:O2 – 20.9%

LEL – 0%H2S – 0ppm

CO- 0ppmBenzene – <0.1ppmTHC - <0.1ppm

Page 15: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 16: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 17: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 18: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 19: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

Page 20: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.

Pump Room Hazard Incident

The Marine Chemist Qualification Board was notified.

U S Coast Guard Eight District was notified.

American Bureau of Shipping, via Francis Calton, was notified.

Page 21: Pump Room Hazard Incident Marine Chemist Association 2012 National Seminar Chicago, IL August 13, 2012.