    Relay Testing Setting CalculationsRelay Coordination Relay CommissioningPanel Commissioning Protection Training

    Http://[email protected]

    Our Relationship with Protection

    & Diagnostics

    POWER SYSTEM PROTECTION & DIAGNOSTICS

    DEVICE SETTINGS RELAYS TESTING REVIEW OF POWER SYSTEM SCENARIOS

    PrecisionEnggServices&C

    onsultancy

    co.

    Prescon offers full range of Power System Protection Services. Startingfrom Consultancy, Design, Prescon now incorporates relay testing includingacceptance testing, commissioning testing and End-to-End testing servicesin its portfolio of ever inreasing Asset management solutions.Prescon has experienced and trained professionals, ETAP - Power SystemDesign Suite and Doble F6150 Relay Testing Sets in addition to presence of alarge library including various IEC and IEEE standards.Prescon can assist you in replacement of relays, installation andcommissioning of complete panels and schemes, setting reviews andcalculations.We are also proudly offering services for upgradation of protectionschemes based on latest Numercial protection relays from anymanufacturer of your choice.In addition to above, we are providing Training services to our clients allover Pakistan and abroad. We can study your system and make a specifictraining program of your desire.Write to us ator for general information.

    [email protected]@theprescon.com

    List of Services Offered:

    ?Power System Design

    ?Protection Relay Settings

    ?Power System Simulation

    ?Relay Coordination

    ?MV/LV Panel Commissioning

    ?MV/LV Testing

    ?Meter Testing

    ?Transducer Testing

    ?Protection Trainings

    ?Primary Injection

    ?Secondary Injection

    ?Protection CT Testing

    ?Upgradation of relays

    If you cannot find services you

    seek in the above list, please do

    not hesitate to contact us.

    mailto:[email protected]:[email protected]:[email protected]:[email protected]
  • 7/30/2019 Protection Services Brochure

    2/2

    The F6150 Simulators are fully capable of testing all types of protective relays, includ-ing these IEEE relay types. In addition, using the Power System Model, P ProTest

    Macro, any relay may be tested under true power system conditions, regardless of it

    measurement function.

    IEEE Device

    Number . . . . .Relay Type . . . . . . . . . . . . . . . . . . . . . . . . Sources

    2 . . . . . . . . . Time Delay and Starting . . . . . . . . . . . . . . 1 Vdc, 1 Idc

    21 . . . . . . . . .Distance 1F. . . . . . . . . . . . . . . . . . . . . . . 1 Vac, 1 Iac

    21 . . . . . . . . Distance, 3Fwye Voltage and Current . . 3 Vac, 3 Iac

    21 . . . . . . . . .Distance 3F(open-delta) . . . . . . . . . . . . 2 Vac, 2 Iac

    21G . . . . . . .Grround Distance . . . . . . . . . . . . . . . . . . 3 Vac, 1 Iac

    24 . . . . . . . . .Volts/Hertz . . . . . . . . . . . . . . . . . . . . . . . . 1 Vac

    25/25G . . . . .Auto-Synchronizing and synch check. . . . 2 Vac

    27/59 . . . . . .AC/DC Under/Overvoltage . . . . . . . . . . . . 1 Vac or 1 Vdc

    32 . . . . . . . . .Directional Power 1F. . . . . . . . . . . . . . . . 1 Vac, 1 Vac

    32 . . . . . . . . .Dirrectional Power 3F(open delta. . . . . . 2 Vac, 2 Iac

    voltages, open wye current)

    37/76 . . . . . . .DC Undercurrent/Overcurrent . . . . . . . . . 1 Idc

    40 . . . . . . . . .Loss of Field . . . . . . . . . . . . . . . . . . . . . . 1 Vac, 1 Iac or 1 Vdc, 1 Idc

    46 . . . . . . . . .Phase Balance . . . . . . . . . . . . . . . . . . . . .3 Iac

    46N . . . . . . .Negative Sequence Overcurrent . . . . . . . 3 Iac

    47 . . . . . . . . .Phase Seq. Voltage (open-delta) . . . . . . . . 2 Vac

    50 . . . . . . . . .Instantaneous Overcurrent (up to 90A. . . 1 Iac

    Continuous, 180A 1.5 Seconds Max.)

    51 . . . . . . . . .Time Overcurrent (up to 90A . . . . . . . . . . 1 Iac

    Continuous, 180A for 1.5 Seconds Max.)

    67 . . . . . Directional Overcurrent . . . . . . . . . . . 1.F:1 Vac, Iac; 3F:3 Vac, 3 lac

    67N . . . . . . .Ground Directional Overcurrent. . . . . . . . 1 Vac, 1 Iac

    79 . . . . . . . . .AC Reclosing . . . . . . . . . . . . . . . . . . . . . . 2 Vac, 1 Logic

    81. . . . . . . . .Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vac or 3 Vac

    82 . . . . . . . . .DC Reclosing . . . . . . . . . . . . . . . . . . . . . . 1 Vdc, 1 Logic

    85 . . . . . . . . .Carrier or Pilot Wire . . . . . . . . . . . . . . . . 1 Idc, 1 Vdc or Iac

    86 . . . . . . . . .Lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vdc

    87 . . . . . . . . .Differential: . . . . . . . . . . . . . . . . . . . . . . . . 1F,2 Iac

    87 . . . . . . . . .Differential: . . . . . . . . . . . . . . . . . . . . . . . . 3F,6 Iac

    94 . . . . . . . . .Tripping . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vdc or 1 Idc