Products and equipment for Medium Voltage distribution ...
Transcript of Products and equipment for Medium Voltage distribution ...
Discovering our offer at a glanceProducts and equipment forMedium Voltage distribution networks 2014
Prod
ucts
and
equ
ipm
ent f
or M
ediu
m V
olta
gedi
strib
utio
n ne
twor
ks
Medium Voltage Circuit Breakers & Contactors 1
Indoor Circuit Breakers 1
Indoor Contactors 3
Outdoor Circuit Breakers 3
Medium Voltage Switchgear 4
Air-Insulated Switchgear (AIS) for Primary Distribution 4
Motor Control 5
Air-Insulated Switchgear (AIS) for Secondary Distribution 5
Gas-Insulated Switchgear (GIS) for Primary Distribution 6
Gas-Insulated Ring Main Units for Secondary Distribution 7
Shielded Solid Insulation System 8
Medium Voltage Fuses 8
Medium Voltage Instrument Transformers 9
Medium Voltage Disconnectors, Switches, Switch-Disconnections, Reclosers
10
Indoor Switch-Disconnectors 10
Pole-Mounted Switchgears 10
Control & Monitoring 12
Medium Voltage components for switchgear control 12
Feeder Automation 12
Remote monitoring and control 13
Protection & control relays 14
Medium Voltage Transformers 16
Oil Immersed Distribution Transformers 16
Oil Immersed Medium Power Transformers 16
Dry type Transformers 16
Special Transformers 16
Power Factor Correction 17
Medium Voltage / Low Voltage prefabricated Substations (PSS)
18
Standard Substations - Integrated 18
Standard Substations - Compact 18
Standard Substations - Walk-In 18
Customized substations 19
Electrical Distribution Services 20
Panorama for MV distribution networks 1
Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers
Indoor Circuit Breakers
LF LFP SF1 SF400 SF2 Evolis 17.5 kV Evolis 24 kV
IEC IEC IEC IEC IEC IEC IEC
Rated voltage (kV)
Max. rated current
3150 A 5000 A 1250 A 2500 A 1250 A 3150 A 2500 A 2500 A 1250 A 2500 A
Max. rated short circuit current
50 kA 40 kA 50 kA 31.5 kA 25 kA 40 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 25 kA 31.5 kA
SF6 SF6 SF6 SF6 SF6 Vacuum Vacuum
Fixedor withdrawableCircuit Breaker
Fixed Circuit Breaker
High power versionfor power pant
Fixed Circuit Breaker
Front or side mountingConventional spring
Integrated VIP trip unit(without auxiliary powersupply) in SFset up to 24 kV(for side mounted)
Suited for capacitor bankapplication
Withdrawable Circuit Breaker
Front mounted
Fixed Circuit Breaker
Front mounted
Fixed orwithdrawable Circuit Breaker
Fixed CircuitBreaker
Sidemounted
VIPintegratedtrip unit
Fixed orwith-drawableCircuit Breaker
Frontmounted
36 36 36
24 24
12 12 1212
17.5 17.5 17.517.5
40.5 40.5
PE
5719
1
PE
9023
0
PE
9023
2
PE
5650
1
PE
5799
4
PE
5800
1
PE
5650
2
Panorama for MV distribution networks www.schneider-electric.com2
Indoor Circuit Breakers Indoor Contactors Outdoor Circuit Breakers
Cradle/Cassette Railway
HVX HVX embedded pole VR VAH VXC ISF2 PMX cradle NEX cradle VXA-VXB Rollarc CBX CLX CPX FVR VOX
IEC/ANSI/GB (Chinese)/GOST standards
GB (Chinese)standards
GB (Chinese)GOST standards
ANSI IEC/ANSI/IEEE IEC IEC EC IEC/GB IEC/ANSI IEC IEC IEC IEC ANSI IEC / ANSI /EATS / GOST
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
2500 A 2500 A* 3150 A 2500 A 2500 A 3000 A 2750 A 8000 A 2500 A 4000 A 3150 A 3150 A 2500 A 2000 A 2500 A 400 A (AC4) 400 A (AC4)
315 A (AC4)
400 A (AC4) 400 A (AC4) 2000 A 2000 A
Max. rated short circuit current Max. rated short circuit current
50 kA 31,5 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 63 kA 40 kA 63 kA* 31.5 kA 40 kA 40 kA 40 kA 31.5 kA 25 kA 40 kA 10 kA 8 kA 6 kA* 4 kA* 6 kA 4 kA 12.5 - 40 kA
12.5 - 25 kA
12.5 - 31.5 kA
40 kA
Vacuum Vacuum Vacuum Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum Vacuum Vacuum / SF6
Fixed or withdrawable Circuit Breaker
* 3150A performance is possible. Please contact us
Fixed or withdrawable Circuit Breaker
Embedded pole for better dielectricand environmental pollution withstand
Withdrawable Fixed orwithdrawableCircuit Breaker.
For generatorapplicationsup to 130 MVA.
* ANSI / IEEEC37.013GeneratorSwitching63 kA, 4000 &5000 A
Fixed orwithdrawableCircuit Breaker.
The arc furnaceCircuit Breakerwith high switchingnumbers,maintenancefree up to25,000/75,000cycles.
Fixed CircuitBreaker forelectrical arcfurnace
Craddlebased onPIXswitchgear
Craddle based on NEXswitchgear
1 or 2-pole circuitbreakerfor railwayapplication or asstar point breakerfor groundingapplication
Fix installation orfloor running truck
- 16 2/3 Hz- 25 Hz- 50Hz- 60 Hz
Fixed or withdrawablecontactor withmagnetic holding ormechanical
Fixed vacuumcontactorIn versionwithdrawable fusedvacuum contactor:CVX
*(50kA in conjunctionwith fuses)
1 or 3 poles
With magnetic holdingor mechanical
Fixed vacuumcontactorwith magneticholding ormechanical
Fixedvacuumcontactorwithmagneticholding ormechanical
Station breaker: fixed outdoor Dead TankCircuit Breaker
Fixed outdoorDead Tank CircuitBreaker
Indoor
24 2427
24
36 36 3638
40.5
17.5 17.5
12 12
15
PE
9023
4
DE
9021
7
PE
9023
6
PM
1026
99
PE
9023
9
PE
9023
8
PE
9024
1
PE
9033
9
Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers
Indoor Contactors
Outdoor Circuit Breakers
Panorama for MV distribution networks 3
Indoor Circuit Breakers Indoor Contactors Outdoor Circuit Breakers
Cradle/Cassette Railway
HVX HVX embedded pole VR VAH VXC ISF2 PMX cradle NEX cradle VXA-VXB Rollarc CBX CLX CPX FVR VOX
IEC/ANSI/GB (Chinese)/GOST standards
GB (Chinese)standards
GB (Chinese)GOST standards
ANSI IEC/ANSI/IEEE IEC IEC EC IEC/GB IEC/ANSI IEC IEC IEC IEC ANSI IEC / ANSI /EATS / GOST
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
2500 A 2500 A* 3150 A 2500 A 2500 A 3000 A 2750 A 8000 A 2500 A 4000 A 3150 A 3150 A 2500 A 2000 A 2500 A 400 A (AC4) 400 A (AC4)
315 A (AC4)
400 A (AC4) 400 A (AC4) 2000 A 2000 A
Max. rated short circuit current Max. rated short circuit current
50 kA 31,5 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 63 kA 40 kA 63 kA* 31.5 kA 40 kA 40 kA 40 kA 31.5 kA 25 kA 40 kA 10 kA 8 kA 6 kA* 4 kA* 6 kA 4 kA 12.5 - 40 kA
12.5 - 25 kA
12.5 - 31.5 kA
40 kA
Vacuum Vacuum Vacuum Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum Vacuum Vacuum / SF6
Fixed or withdrawable Circuit Breaker
* 3150A performance is possible. Please contact us
Fixed or withdrawable Circuit Breaker
Embedded pole for better dielectricand environmental pollution withstand
Withdrawable Fixed orwithdrawableCircuit Breaker.
For generatorapplicationsup to 130 MVA.
* ANSI / IEEEC37.013GeneratorSwitching63 kA, 4000 &5000 A
Fixed orwithdrawableCircuit Breaker.
The arc furnaceCircuit Breakerwith high switchingnumbers,maintenancefree up to25,000/75,000cycles.
Fixed CircuitBreaker forelectrical arcfurnace
Craddlebased onPIXswitchgear
Craddle based on NEXswitchgear
1 or 2-pole circuitbreakerfor railwayapplication or asstar point breakerfor groundingapplication
Fix installation orfloor running truck
- 16 2/3 Hz- 25 Hz- 50Hz- 60 Hz
Fixed or withdrawablecontactor withmagnetic holding ormechanical
Fixed vacuumcontactorIn versionwithdrawable fusedvacuum contactor:CVX
*(50kA in conjunctionwith fuses)
1 or 3 poles
With magnetic holdingor mechanical
Fixed vacuumcontactorwith magneticholding ormechanical
Fixedvacuumcontactorwithmagneticholding ormechanical
Station breaker: fixed outdoor Dead TankCircuit Breaker
Fixed outdoorDead Tank CircuitBreaker
Indoor
24 2517.5
7.2 7.2 7.212 12
DS
CF2
305
PE
6024
7
PM
1037
84
Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers
Indoor Contactors
Outdoor Circuit Breakers
PE
9028
4
3.6
PM
1037
87
15
27
38 38
PE
9025
0
PE
9025
0
PM
1037
89
Panorama for MV distribution networks www.schneider-electric.com4
AIS for Primary Distribution Motor Control AIS for Secondary Distribution
Air Insulated Switchgear up to 24 kV Railway
MCset PIX PIX Double Busbar
PIX High NEX GenieEvo DNF7 F400 Masterclad PIX DC Motorpact PIX MCC SM6-24 SM6-36 HVL HVL/cc
IEC IEC/GOST
IEC IEC/GOST IEC/GB IEC IEC IEC IEC/GB/GOST IEC / GOST ANSI/UL IEC/EN IEC/NEMA IEC IEC IEC ANSI ANSI
Rated voltage (kV) Rated voltage (kV)
LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2A-PI LSC2B-PM LSC2A-PI LSC 2B-PM
Max. rated current Max. rated current
4000 A 2500 A 4000 A 2500 A 3150 A 5000 A 2500 A 2500 A 2000 A 2000 A 2000 A (SF CB)2500 A (Vacuum CB). For 3150 A, please consult us.
2500 A 1250 A 4000 A 2750 A 4000 A 3150 A 5000 A (busbars) 630 A & 1250A 630 A 1250 A 1200 A 1200 A
LSC2B-PM 400 A contactor
Max. rated short circuit current Max. rated short circuit current
50 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 50 kA 31.5 kA 31.5 kA 25 kA 25 kA 31.5 kA 40 kA 31.5 kA 63 kA 40 kA 50 kA 50 kA 25 kA 20 kA 25 kA 20 to 61 kA 32 kA 40 kA
Vacuum*SF6
SF6 Vacuum* Vacuum Vacuum Vacuum Vacuum Vacuum / SF6 SF6 Vacuum Air Vacuum Vacuum SF6Vacuum CB
SF6 CB Open-air switch SF6 switch
Single busbar system,Withdrawable CircuitBreaker
* Limited 31.5 kA / 2000A. Above, please consult us.
Single busbarsystem,WithdrawableCircuit Breaker
* SF6 technology, please refer to MCset
Double busbar system,WithdrawableCircuit Breaker
Single busbarsystemWithdrawableCircuit Breaker
Single busbar systemWithdrawable VaccumCircuit Breaker
Single busbarsystemFixed typeRear cableaccess
Single busbarsystem
* up to48 kV/20 kA
Single busbarsystem
Single busbar system
For light railwaysegment(tram/metro)
Width 650 mm
Withdrawabledouble busbarfor S3DOLRVSSRVATReversing 2-speed
WithdrawableDirect line-upwith PIXFront accesscabling(rear option)DOL and feederapplications
Complete system of modular cubicles
Complete system of modular cubicles
Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available
Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available
Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor & Outdoor Indoor & Outdoor NEMA
Indoor Indoor Indoor
IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC
40.5
121213.8
17.517.517.517.5 17.52424 24
PE
5746
6
DM
1021
84
Medium Voltage SwitchgearsAir-Insulated Switchgear (AIS) for Primary Distribution
Motor Control
Air-Insulated Switchgear (AIS) for Secondary Distribution
PM
1035
75
PM
1028
25
PE
9020
8
PM
1030
10
PE
9027
2
PE
9027
1
36
40.5
Panorama for MV distribution networks 5
AIS for Primary Distribution Motor Control AIS for Secondary Distribution
Air Insulated Switchgear up to 24 kV Railway
MCset PIX PIX Double Busbar
PIX High NEX GenieEvo DNF7 F400 Masterclad PIX DC Motorpact PIX MCC SM6-24 SM6-36 HVL HVL/cc
IEC IEC/GOST
IEC IEC/GOST IEC/GB IEC IEC IEC IEC/GB/GOST IEC / GOST ANSI/UL IEC/EN IEC/NEMA IEC IEC IEC ANSI ANSI
Rated voltage (kV) Rated voltage (kV)
LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2A-PI LSC2B-PM LSC2A-PI LSC 2B-PM
Max. rated current Max. rated current
4000 A 2500 A 4000 A 2500 A 3150 A 5000 A 2500 A 2500 A 2000 A 2000 A 2000 A (SF CB)2500 A (Vacuum CB). For 3150 A, please consult us.
2500 A 1250 A 4000 A 2750 A 4000 A 3150 A 5000 A (busbars) 630 A & 1250A 630 A 1250 A 1200 A 1200 A
LSC2B-PM 400 A contactor
Max. rated short circuit current Max. rated short circuit current
50 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 50 kA 31.5 kA 31.5 kA 25 kA 25 kA 31.5 kA 40 kA 31.5 kA 63 kA 40 kA 50 kA 50 kA 25 kA 20 kA 25 kA 20 to 61 kA 32 kA 40 kA
Vacuum*SF6
SF6 Vacuum* Vacuum Vacuum Vacuum Vacuum Vacuum / SF6 SF6 Vacuum Air Vacuum Vacuum SF6Vacuum CB
SF6 CB Open-air switch SF6 switch
Single busbar system,Withdrawable CircuitBreaker
* Limited 31.5 kA / 2000A. Above, please consult us.
Single busbarsystem,WithdrawableCircuit Breaker
* SF6 technology, please refer to MCset
Double busbar system,WithdrawableCircuit Breaker
Single busbarsystemWithdrawableCircuit Breaker
Single busbar systemWithdrawable VaccumCircuit Breaker
Single busbarsystemFixed typeRear cableaccess
Single busbarsystem
* up to48 kV/20 kA
Single busbarsystem
Single busbar system
For light railwaysegment(tram/metro)
Width 650 mm
Withdrawabledouble busbarfor S3DOLRVSSRVATReversing 2-speed
WithdrawableDirect line-upwith PIXFront accesscabling(rear option)DOL and feederapplications
Complete system of modular cubicles
Complete system of modular cubicles
Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available
Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available
Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor & Outdoor Indoor & Outdoor NEMA
Indoor Indoor Indoor
IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC
Medium Voltage SwitchgearsAir-Insulated Switchgear (AIS) for Primary Distribution
Motor Control
Air-Insulated Switchgear (AIS) for Secondary Distribution
PE
9027
6
15
27
0.75 1.5
PE
9029
1
7.2 7.2
PE
9026
6
PM
1030
07
PE
9069
8
PE
9069
9
PE
9070
0
PE
9070
1
24
12
3638 38
Panorama for MV distribution networks www.schneider-electric.com6
Medium Voltage SwitchgearsGas-Insulated Switchgear (GIS) for Primary Distribution
Gas-Insulated Ring Main Units for Secondary Distribution
Gas-Insulated Switchgear (GIS) for Primary Distribution Gas-Insulated Ring Main Units for Secondary Distribution
Railway
GMA CBGS-0 WS GHA CBGS 2 WI GHA Rail WI Rail CBGS-0 CBGS-2 Ringmaster FBX RM6 DVCAS Flusarc
IEC / GOST /CNS
IEC/ANSI (UL) IEC / GOST /CNS
IEC / GOST /CNS
IEC IEC / GOST /CNS
IEC/GB (China) IEC/EN IEC IEC IEC IEC IEC IEC/ANSI/UL IEC
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
2500 A 2000 A 2000 A 2500 A 2500 A 2000 A 2500 A 2000 A 2000 A 1250 A 2000 A 630 A 630 A 630 A 630 A 630 A 630 A
option busbar1250A
Max. rated short circuit current Max. rated short circuit current
31.5 kA 31.5 kA 31.5 kA 40 kA 25 kA 40 kA 25 kA 31.5 kA 25 kA 25 kA 21 kA 25 kA 21 kA 25 kA 20 kA 20 kA 25 kA
Vacuum SF6 Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 SF6 SF6 CBSF6 LBS
Vacuum CBSF6 LBS
SF6 CBSF6 LBS
Vacuum CBSF6 LBS
Vacuum CBSF6 LBS
Single busbarsystemFixed typeMainly with C.B.but also switch-disconnectorfunctionsLess Space-MorePower verycompact designFlexible busbarsystemOuter cone cableconnectionNo gas handling
Single busbar systemFixed typeMainly with C.B. but also switch-disconnectorfunctions
Compact design at 36kVFlexible busbarsystemOuter cone cableconnectionNo gas handling
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Same smallfootprint forSBB and DBB,spacious cableconnection innercone
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Compact design,flexible cableconnection forouter cone andinner cone, nogas handling
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Spacious cableconnection innercone
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar.
Same small foot-print for SBB andDBB, spaciouscable connectioninner cone
Single busbarsystemFixed typeFor tractionapplication1 or 2 polesolution
BIL 200 kV,suitablefor traction sidecontainerSubstationNo gas handling
Single busbarsystemFixed typeFor tractionapplication,1 or 2 polesolution
BIL 250 kV,suiteable fortraction sidecontainerSubstation
For railwayapplication 1 pole(170kV BIL)
For railwayapplication 1 or 2poles (250kV BIL)Single busbarsystemFixed typeFor tractionapplication, 1 or 2pole solution
BIL 250 kV,suiteable fortraction sidecontainerSubstation
Compact and modularswitchgearcombining all MV functional units
Compact and modularswitchgear combining all MV functional units
Compactand modularswitchgearcombining all MVfunctional units
Wind dedicatedmodular switchgearcombiningall MV functionalunits used in windfarms
Compact and modularswitchgear combiningall MV functional units
Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor andoutdoor
Indoor Indoor Indoor Indoor & Outdoor
Indoor
IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC
24
36 36
52 5240.5
38
PM
1030
68
PM
1028
31
PM
1028
33
PE
9069
7
PM
1030
08
PM
1028
34
PE
9070
5
PM
1027
06
2 x 27.5
2 x 27.5
1 x 27.5
1 x 27.5
Panorama for MV distribution networks 7
Medium Voltage SwitchgearsGas-Insulated Switchgear (GIS) for Primary Distribution
Gas-Insulated Ring Main Units for Secondary Distribution
Gas-Insulated Switchgear (GIS) for Primary Distribution Gas-Insulated Ring Main Units for Secondary Distribution
Railway
GMA CBGS-0 WS GHA CBGS 2 WI GHA Rail WI Rail CBGS-0 CBGS-2 Ringmaster FBX RM6 DVCAS Flusarc
IEC / GOST /CNS
IEC/ANSI (UL) IEC / GOST /CNS
IEC / GOST /CNS
IEC IEC / GOST /CNS
IEC/GB (China) IEC/EN IEC IEC IEC IEC IEC IEC/ANSI/UL IEC
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
2500 A 2000 A 2000 A 2500 A 2500 A 2000 A 2500 A 2000 A 2000 A 1250 A 2000 A 630 A 630 A 630 A 630 A 630 A 630 A
option busbar1250A
Max. rated short circuit current Max. rated short circuit current
31.5 kA 31.5 kA 31.5 kA 40 kA 25 kA 40 kA 25 kA 31.5 kA 25 kA 25 kA 21 kA 25 kA 21 kA 25 kA 20 kA 20 kA 25 kA
Vacuum SF6 Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 SF6 SF6 CBSF6 LBS
Vacuum CBSF6 LBS
SF6 CBSF6 LBS
Vacuum CBSF6 LBS
Vacuum CBSF6 LBS
Single busbarsystemFixed typeMainly with C.B.but also switch-disconnectorfunctionsLess Space-MorePower verycompact designFlexible busbarsystemOuter cone cableconnectionNo gas handling
Single busbar systemFixed typeMainly with C.B. but also switch-disconnectorfunctions
Compact design at 36kVFlexible busbarsystemOuter cone cableconnectionNo gas handling
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Same smallfootprint forSBB and DBB,spacious cableconnection innercone
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Compact design,flexible cableconnection forouter cone andinner cone, nogas handling
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar
Spacious cableconnection innercone
Single and doublebusbar systemFixed typeCB applications
Separated gas-compartmentsfor CB and busbar.
Same small foot-print for SBB andDBB, spaciouscable connectioninner cone
Single busbarsystemFixed typeFor tractionapplication1 or 2 polesolution
BIL 200 kV,suitablefor traction sidecontainerSubstationNo gas handling
Single busbarsystemFixed typeFor tractionapplication,1 or 2 polesolution
BIL 250 kV,suiteable fortraction sidecontainerSubstation
For railwayapplication 1 pole(170kV BIL)
For railwayapplication 1 or 2poles (250kV BIL)Single busbarsystemFixed typeFor tractionapplication, 1 or 2pole solution
BIL 250 kV,suiteable fortraction sidecontainerSubstation
Compact and modularswitchgearcombining all MV functional units
Compact and modularswitchgear combining all MV functional units
Compactand modularswitchgearcombining all MVfunctional units
Wind dedicatedmodular switchgearcombiningall MV functionalunits used in windfarms
Compact and modularswitchgear combiningall MV functional units
Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor andoutdoor
Indoor Indoor Indoor Indoor & Outdoor
Indoor
IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC
DE
6048
8
PM
1028
33
24 24
12 1213.8
2 x 27.5
1 x 27.5
1 x 27.5
36 36
40.538
DM
1026
66
PE
5777
0
PE
9070
2
PE
9070
3
PE
9070
4
Panorama for MV distribution networks www.schneider-electric.com8
2SIS MV Fuses
Premset Fusarc CF Solefuse Tepefuse, Fusarc CF
MGK
IEC DIN/IEC IEC/UTE IEC/DIN/UTE AFNOR
Rated voltage (kV)
Max. rated current
630 A 250 A 5000 A (busbars)
400 A contactor
Max. rated short circuit current
25 kA 63 kA 50 kA 63 kA 50 kA
Vacuum CB
Compact modular switchgear with 3-in-1 architecture for breaking- disconnection and earthing
Fuses fordistributiontransformer protectionfrom 3.6 kV to 36 kV
Fuses for distribution transformer protection from 3.6 kV to 36 kV
Fuse for measurementtransformer protection up to24 kV (Tepefuse) and up to36 kV (Fusarc CF)Back-up technology
Motorprotectionfuse range
Indoor & Outdoor
IAC
36 36 36
12
15
PM
1005
99
PE
9070
6
Medium Voltage SwitchgearsShielded Solid Insulation System (2SIS)
Medium Voltage Fuses
Medium Voltage Instrument Transformers
7.2
Panorama for MV distribution networks 9
Medium Voltage SwitchgearsShielded Solid Insulation System (2SIS)
Medium Voltage Fuses
Medium Voltage Instrument Transformers
MV Instrument Transformers
IndoorCT / VT
Sensor Low VoltageRing Core
OutdoorCT / VT
IndoorCT / VT
CombinedOutdoor Unit
OutdoorVT
IEC IEC IEC IEC IEC/IEEE IEC/IEEE IEC/IEEE
Rated voltage (kV)
Max. rated current
2500 A 2500 A 5000 A 2500 A 3000 A 600 A 1500 A
Max. rated short circuit current
50 kA 40 kA 40 kA 50 kA 50 kA 50 kA 40 kA
Dry Dry Dry Dry Dry Dry Dry
Medium VoltageCurrentTransformer,VoltageTransformer
Ring type andMedium VoltageLow Power CurrentTransformer (LPCT)
Ring typeLow Voltage Transformer
Outdoor CurrentTransformer and VoltageTransformer
Ring or Bar typeCurrent Transformer andVoltageTransformer
Outdoorcombined CTsVTs measureunits for aerianand undergroundapplications
Outdoor CurrentTransformerand VoltageTransformer
36
72
36
40.540.5
0.72
24
PE
9029
6
PE
9030
2
PE
9030
3
PM
1030
13
PE
9029
7
PE
9052
9
PM
1030
14
PM
1030
05
Panorama for MV distribution networks www.schneider-electric.com10
Medium Voltage Disconnectors, Switches, Switch-Disconnections, ReclosersIndoor Switch-Disconnectors
Pole-Mounted Switchgears
Indoor Switch-Disconnectors Pole mounted switchgears
Railway
LBSkit L-TRI 5 TRI PM6 PM6 52 RL series N series U series W series SBC SDR CBR 22 CB NE TILF
IEC IEC IEC IEC IEC IEC/ANSI IEC/ANSI IEC/ANSI IEC/ANSI IEC IEC IEC IEC IEC/SNCB IEC/SNCB
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
630/1250 A 630/1600/2500 A 630 A 630 A 630 A 800 A 630 A 400 A 630 A 2000 A 2000 A 1000 A 2000 A 3150 A
Max. rated short circuit current Max. rated short circuit current
25 kA 20 kA 20 kA 16 kA 12.5 kA / 3 s 16 kA 16 kA 12.5 kA 6 kA 20 kA 25 kA/ 40 kA
8 kA/ 25 kA
25 kA 16 kA 25 kA 25 kA
SF6 AIR AIR SF6 SF6 Vacuum / SF6 Vacuum / SF6 Vacuum / Epoxy Vacuum / Epoxy Air Vacuum Vacuum Vacuum
Indoor load breakswitch, disconnector and accessories
Indoor loadbreak switchdisconnectorandaccessories
Indoordisconnectorandaccessories
Load break switch
Remote controlled with Easergy T200 P control unit
Manual or automatic load break switch
Sectionaliser capabilities
Load break switch
Remote controlled with ADVC controller
Manual orautomaticload break switch
Sectionalisercapabilitieson voltage and current
Recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Single Wire Earth Return (SWER)recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Air break switch and disconnector
Manualy operated
Fixed load breakswitch for AC railwayapplication
Fixed CircuitBreaker forAC railwayapplication
For locomotives and ElectricMultiple Units (EMU)
Outdoor on locomotive top
Single pole loadbreak switchesfor DC railwaynetworks
Single pole loadbreak switchesfor DC railwaynetworks
Outdoor Outdoor On board
3636363638 38
52
12
PE
9071
2
PE
9071
1
PE
9071
0
PE
9070
9
PE
9070
8
PE
9070
7
Panorama for MV distribution networks 11
Medium Voltage Disconnectors, Switches, Switch-Disconnections, ReclosersIndoor Switch-Disconnectors
Pole-Mounted Switchgears
Indoor Switch-Disconnectors Pole mounted switchgears
Railway
LBSkit L-TRI 5 TRI PM6 PM6 52 RL series N series U series W series SBC SDR CBR 22 CB NE TILF
IEC IEC IEC IEC IEC IEC/ANSI IEC/ANSI IEC/ANSI IEC/ANSI IEC IEC IEC IEC IEC/SNCB IEC/SNCB
Rated voltage (kV) Rated voltage (kV)
Max. rated current Max. rated current
630/1250 A 630/1600/2500 A 630 A 630 A 630 A 800 A 630 A 400 A 630 A 2000 A 2000 A 1000 A 2000 A 3150 A
Max. rated short circuit current Max. rated short circuit current
25 kA 20 kA 20 kA 16 kA 12.5 kA / 3 s 16 kA 16 kA 12.5 kA 6 kA 20 kA 25 kA/ 40 kA
8 kA/ 25 kA
25 kA 16 kA 25 kA 25 kA
SF6 AIR AIR SF6 SF6 Vacuum / SF6 Vacuum / SF6 Vacuum / Epoxy Vacuum / Epoxy Air Vacuum Vacuum Vacuum
Indoor load breakswitch, disconnector and accessories
Indoor loadbreak switchdisconnectorandaccessories
Indoordisconnectorandaccessories
Load break switch
Remote controlled with Easergy T200 P control unit
Manual or automatic load break switch
Sectionaliser capabilities
Load break switch
Remote controlled with ADVC controller
Manual orautomaticload break switch
Sectionalisercapabilitieson voltage and current
Recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Single Wire Earth Return (SWER)recloser
Remote controlled with ADVC controller
Advanced protection, control andcommunication
Air break switch and disconnector
Manualy operated
Fixed load breakswitch for AC railwayapplication
Fixed CircuitBreaker forAC railwayapplication
For locomotives and ElectricMultiple Units (EMU)
Outdoor on locomotive top
Single pole loadbreak switchesfor DC railwaynetworks
Single pole loadbreak switchesfor DC railwaynetworks
Outdoor Outdoor On board
3627
24
PM
1026
91
PE
9071
5
PE
9071
4
PE
9071
3
PM
1026
89
PE
9029
2
PE
9028
9
PE
9029
0
25 (1ph)
27.527.5
15
3.8 3.8
Panorama for MV distribution networks www.schneider-electric.com12
Control & Monitoring
MV components for switchgear control Feeder Automation Remote monitoring and control
Remote Control for MV Substations Remote Monitoring for MV Substations
MV/LV Substation power supply
Fault Passage Indicators for Underground Networks Telecontrol interface for pole-mounted load-break switch
Remote Monitoring for Overhead Networks
Fault Passage Indicators for Overhead Networks
GemStart 5.4 GemStart 5 GemView GemControl Easergy L500 EasergyT200I - T200E
Easergy R200-ATS100
EasergyFlair 200C
Easergy PS100 Easergy Flair 219, 279
Easergy Flair 510, 570, 590
Easergy Flair 21D, 22D, 23D, 23DM
Easergy T200P ADVC Easergy Flite 116-SA/G200
Easergy Flite ILIS
Ideal for IEC MV & LV motor starters with ratings from 0.5 kW to2 MW. Partnered with PIX MCC and also suitable for Motorpact/ OKKEN
Applications:Integrated MotorControl andProtection. Multiline LCD front panel, multi voltage inputsolution requiring no interposing relays.Exclusive MemoryModule (PAMM),Self Tuningprotection. Industryleader and standard in many Oil & Gasapplicationsworld-wide
Protocols:Modbus RTU,Profi bus DP V1using Generic MotorManagement profilefor plug and play solutions
Hand HeldProgrammerExclusive toGemStart5 Highestpossible security.Avoids the use oflaptopRequires a Key forprotection modification
Applications:Ensures fullcompliance with best practice and permit to work principles inOil & Gasapplications.Work at a convenientheight with userfriendly control and reset buttons.Only authorisedoperators mayconfi gure or reset trips
PLC and PC based solution for MV & LV Process control systems. Partneredwith GemStart 5,PIX MCC and LVSwitchgear
Applications:Intelligent MotorControl andMonitoring System(IMCS) to Chevron, Shell, BP, ExxonMobil, Conoco Philips and most other Oil & Gas standardsPredictivemaintenance,trending, alarms,plant visualisationin a semi standard/ custom package.Completes the Oil & Gas solution offer.
Protocols:Modbus RTU,Profi bus DP V1,Ethernet TCP I/PA library of otherprotocols is availableto integrate otherdevices andprotection relays
Smart SwitchgearManagementDigital control & monitoringsolution for air-insulated andgas-insulated switchgear fromsimple to complexapplications, due to its very scalable design
Applications:Switchgear central control unit, central monitoring and central information source, separated from protectionfunction.Advanced front panel for safeand intuitive guided operation.Base Unit with open SCADA-Communication for standard IEC-protocols andindustry protocols.Sofware based on robust standard PLC software.Direct process control possible
Protocols:IEC 60870-5-101Modbus-RTUProfibus-DPIEC 60870-5-103IEC 60870-5-104IEC 61850, Modbus TCP
Remote control system
Capacity500 Easergy type devicesNetwork and substation viewsAlarm logs, archives
Data configurationProfessional communicationsand database editorData creation via dialogueboxes
ProtocolsModbus, Modbus IP, IEC 101/104
CommunicationPermanent and non permanent:telephone/GSM, radio, direct public and dedicatedprivate linePeriodic call management
OptionWebview, Multistation andHorn/Lamp indication options
Switchmonitoring andcontrol unit
Fault indicator:phase and earth fault
Capacity1-16 switches
Batteryautonomy 16 h
Motorisation24 - 48 VDC
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS, 3G
Programmation IEC 61131-3
Modbus IEDsconcentrator
Switchmonitoring andcontrol unit
Control and monitoring through embedded devices in MV switchgear Premset, SM6 (end 2014)
Fault indicator: Flair 23DM
Control unit: SC110
Backup power supply: PS100
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS, 3G
Modbus IEDsconcentrator
DetectionPhase and earth fault
InstallationWall-mounted
Earthingsystem: direct,impedent,compensated, isolated
MeasurementU,I, P, Q, S, cosϕ6 D.I., 3 D.O.
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
Communication1 communication portTransmission interfaces:PSTN, radio, GSM, GPRS,Ethernet, RS232, RS485...
Modbus IEDsconcentrator
Power supply and battery charger for MV/LV substation.
24V or 48V for motor and IEDs supply12V for communication device supply
Autonomy up to 48h
90W for 24/48V permanent load300W 1mn for motor supply10kV insulation
Monitoring of battery to detect end of life through Modbus communication
Detectionphase and earth fault
Settingon site by dip switch
Installationwall mounted3 phases or / andearth CT
Earthing systemdirect, impedant
Detectionphase and earth fault
Settingon site by HMI throughpush buttons
Installationwall mounted3 phases or / andearth CT
Earthing systemdirect, impedant, compensated, isolated
Detectionphase and earth fault
Settingon site by dip switch or with keyboard
InstallationDIN formatintegrated into switchgear
Earthing system direct impedant, compensated, isolated
Measurementammeter,maximeter
Switch or sectionalisermonitoring and control unit
Fault indicator: phase and earth fault
MeasurementCurrent, voltage, real power,reactive power, power factor, demand, cosϕ
Capacity2 switches
Battery autonomy16h
Motorisation voltage24-48 VDC
ProtocolsModbus, Modbus/IP, IEC 870-5-101/104, DNP3,DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS 3G
Modbus IEDsconcentrator
ControlControls recloser
ProtectionPhase and earth current,directional, voltage, frequency,harmonics
DetectionPhase and earth faults, directional
MeasurementCurrent, voltage, real power,power factor, demand,harmonics, supply outages,waveform capture
SettingBy laptop, operator control panel, Scada
InstallationMounted on the pole or substation frame
ProtocolsDNP3, IEC 870-5-101/104Modbus/IP and DNP3/IP
CommunicationRadio, modem, GSM, V23,RS232, RS485, 10BaseT Ethernet
DetectionPhase-to-phase and phase-to-earth fault
Installationclip on or G200 pole mounted
ProtocolsIEC 870-5-101, SerialDNP3 and TCP/IP,Modbus
Communication915 MHz short range radio communication1 SCADA communicationportTransmission interface:radio, GSM, GPRS
Detectionphase and earth fault
Settingon site by dip switch
Installationclip on or polemounted
Earthing systemdirect, impedant,compensated,isolated
ILIS (Intelligent LightInformation System)Monitors light levelswithin SwitchgearcompartmentsApplications:Detects anddisconnects ARCfaults to limit damageto equipment. Diffuselight collection fromall directions, rapidtimed disconnectbetween 5 and250mS.Monitors up to 4compartments percolumn and up to 5columns on 4independant loops
Digital Digital PLC / PC /Software
Digital Scada Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Associated with all types of MV switchgear
T200E associated with Ringmaster only; limited to 4 switches.
Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration
Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration
ATS100: automatic source transfer with dedicated front panel.Lines, generator, bus tie
MV substation remotemonitoring unit
Battery220 VAC backed-up supply
Embedded web server.Local and remoteconfiguration
7 to 40 Ah lead long life batteryInput voltage:- 110 to 240 VAC- 110 VDC
Phase and earth fault indicator forunderground network
Power supply: - Flair 219: lithium battery - Flair 279: 220 VAC with backup lithium battery
1 output contact
Phase and earth fault indicator forunderground network
Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor
2 output contacts2 input contacts
Phase and earth fault indicator forunderground network. Self powered by CTs
Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor
2 output contacts2 input contacts
Associated with a pole mounted switch
Ensures remote controland automatedmanagement
Embedded web server.Local and remoteconfiguration
Advanced controller associated with N, U and W Seriesreclosers, and RL Series sectionaliser
Remote setting with WSOS monitoringand control software
Electronics sealed to IP65, 316 grade stainless steel enclosure
Control recloser Load Break Switch/Sectionnaliser type RL series
Communicating fault currentdetector for overheadlinesSingle-phaseammetric detector
Earth andphase-to-phase fault indicatorsfor overheaddistribution linesLithiumbattery power
PM
1028
20
PE
9029
5
PM
1028
22
PE
9034
3 V
3
DM
1030
98
PM
1023
01
DM
1030
99
PE
9071
6
PE
9071
7
PE
9071
8
Panorama for MV distribution networks 13
Control & Monitoring
MV components for switchgear control Feeder Automation Remote monitoring and control
Remote Control for MV Substations Remote Monitoring for MV Substations
MV/LV Substation power supply
Fault Passage Indicators for Underground Networks Telecontrol interface for pole-mounted load-break switch
Remote Monitoring for Overhead Networks
Fault Passage Indicators for Overhead Networks
GemStart 5.4 GemStart 5 GemView GemControl Easergy L500 EasergyT200I - T200E
Easergy R200-ATS100
EasergyFlair 200C
Easergy PS100 Easergy Flair 219, 279
Easergy Flair 510, 570, 590
Easergy Flair 21D, 22D, 23D, 23DM
Easergy T200P ADVC Easergy Flite 116-SA/G200
Easergy Flite ILIS
Ideal for IEC MV & LV motor starters with ratings from 0.5 kW to2 MW. Partnered with PIX MCC and also suitable for Motorpact/ OKKEN
Applications:Integrated MotorControl andProtection. Multiline LCD front panel, multi voltage inputsolution requiring no interposing relays.Exclusive MemoryModule (PAMM),Self Tuningprotection. Industryleader and standard in many Oil & Gasapplicationsworld-wide
Protocols:Modbus RTU,Profi bus DP V1using Generic MotorManagement profilefor plug and play solutions
Hand HeldProgrammerExclusive toGemStart5 Highestpossible security.Avoids the use oflaptopRequires a Key forprotection modification
Applications:Ensures fullcompliance with best practice and permit to work principles inOil & Gasapplications.Work at a convenientheight with userfriendly control and reset buttons.Only authorisedoperators mayconfi gure or reset trips
PLC and PC based solution for MV & LV Process control systems. Partneredwith GemStart 5,PIX MCC and LVSwitchgear
Applications:Intelligent MotorControl andMonitoring System(IMCS) to Chevron, Shell, BP, ExxonMobil, Conoco Philips and most other Oil & Gas standardsPredictivemaintenance,trending, alarms,plant visualisationin a semi standard/ custom package.Completes the Oil & Gas solution offer.
Protocols:Modbus RTU,Profi bus DP V1,Ethernet TCP I/PA library of otherprotocols is availableto integrate otherdevices andprotection relays
Smart SwitchgearManagementDigital control & monitoringsolution for air-insulated andgas-insulated switchgear fromsimple to complexapplications, due to its very scalable design
Applications:Switchgear central control unit, central monitoring and central information source, separated from protectionfunction.Advanced front panel for safeand intuitive guided operation.Base Unit with open SCADA-Communication for standard IEC-protocols andindustry protocols.Sofware based on robust standard PLC software.Direct process control possible
Protocols:IEC 60870-5-101Modbus-RTUProfibus-DPIEC 60870-5-103IEC 60870-5-104IEC 61850, Modbus TCP
Remote control system
Capacity500 Easergy type devicesNetwork and substation viewsAlarm logs, archives
Data configurationProfessional communicationsand database editorData creation via dialogueboxes
ProtocolsModbus, Modbus IP, IEC 101/104
CommunicationPermanent and non permanent:telephone/GSM, radio, direct public and dedicatedprivate linePeriodic call management
OptionWebview, Multistation andHorn/Lamp indication options
Switchmonitoring andcontrol unit
Fault indicator:phase and earth fault
Capacity1-16 switches
Batteryautonomy 16 h
Motorisation24 - 48 VDC
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS, 3G
Programmation IEC 61131-3
Modbus IEDsconcentrator
Switchmonitoring andcontrol unit
Control and monitoring through embedded devices in MV switchgear Premset, SM6 (end 2014)
Fault indicator: Flair 23DM
Control unit: SC110
Backup power supply: PS100
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS, 3G
Modbus IEDsconcentrator
DetectionPhase and earth fault
InstallationWall-mounted
Earthingsystem: direct,impedent,compensated, isolated
MeasurementU,I, P, Q, S, cosϕ6 D.I., 3 D.O.
ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP
Communication1 communication portTransmission interfaces:PSTN, radio, GSM, GPRS,Ethernet, RS232, RS485...
Modbus IEDsconcentrator
Power supply and battery charger for MV/LV substation.
24V or 48V for motor and IEDs supply12V for communication device supply
Autonomy up to 48h
90W for 24/48V permanent load300W 1mn for motor supply10kV insulation
Monitoring of battery to detect end of life through Modbus communication
Detectionphase and earth fault
Settingon site by dip switch
Installationwall mounted3 phases or / andearth CT
Earthing systemdirect, impedant
Detectionphase and earth fault
Settingon site by HMI throughpush buttons
Installationwall mounted3 phases or / andearth CT
Earthing systemdirect, impedant, compensated, isolated
Detectionphase and earth fault
Settingon site by dip switch or with keyboard
InstallationDIN formatintegrated into switchgear
Earthing system direct impedant, compensated, isolated
Measurementammeter,maximeter
Switch or sectionalisermonitoring and control unit
Fault indicator: phase and earth fault
MeasurementCurrent, voltage, real power,reactive power, power factor, demand, cosϕ
Capacity2 switches
Battery autonomy16h
Motorisation voltage24-48 VDC
ProtocolsModbus, Modbus/IP, IEC 870-5-101/104, DNP3,DNP3/IP
CommunicationRadio, PSTN, GSM, GPRS 3G
Modbus IEDsconcentrator
ControlControls recloser
ProtectionPhase and earth current,directional, voltage, frequency,harmonics
DetectionPhase and earth faults, directional
MeasurementCurrent, voltage, real power,power factor, demand,harmonics, supply outages,waveform capture
SettingBy laptop, operator control panel, Scada
InstallationMounted on the pole or substation frame
ProtocolsDNP3, IEC 870-5-101/104Modbus/IP and DNP3/IP
CommunicationRadio, modem, GSM, V23,RS232, RS485, 10BaseT Ethernet
DetectionPhase-to-phase and phase-to-earth fault
Installationclip on or G200 pole mounted
ProtocolsIEC 870-5-101, SerialDNP3 and TCP/IP,Modbus
Communication915 MHz short range radio communication1 SCADA communicationportTransmission interface:radio, GSM, GPRS
Detectionphase and earth fault
Settingon site by dip switch
Installationclip on or polemounted
Earthing systemdirect, impedant,compensated,isolated
ILIS (Intelligent LightInformation System)Monitors light levelswithin SwitchgearcompartmentsApplications:Detects anddisconnects ARCfaults to limit damageto equipment. Diffuselight collection fromall directions, rapidtimed disconnectbetween 5 and250mS.Monitors up to 4compartments percolumn and up to 5columns on 4independant loops
Digital Digital PLC / PC /Software
Digital Scada Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Associated with all types of MV switchgear
T200E associated with Ringmaster only; limited to 4 switches.
Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration
Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration
ATS100: automatic source transfer with dedicated front panel.Lines, generator, bus tie
MV substation remotemonitoring unit
Battery220 VAC backed-up supply
Embedded web server.Local and remoteconfiguration
7 to 40 Ah lead long life batteryInput voltage:- 110 to 240 VAC- 110 VDC
Phase and earth fault indicator forunderground network
Power supply: - Flair 219: lithium battery - Flair 279: 220 VAC with backup lithium battery
1 output contact
Phase and earth fault indicator forunderground network
Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor
2 output contacts2 input contacts
Phase and earth fault indicator forunderground network. Self powered by CTs
Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor
2 output contacts2 input contacts
Associated with a pole mounted switch
Ensures remote controland automatedmanagement
Embedded web server.Local and remoteconfiguration
Advanced controller associated with N, U and W Seriesreclosers, and RL Series sectionaliser
Remote setting with WSOS monitoringand control software
Electronics sealed to IP65, 316 grade stainless steel enclosure
Control recloser Load Break Switch/Sectionnaliser type RL series
Communicating fault currentdetector for overheadlinesSingle-phaseammetric detector
Earth andphase-to-phase fault indicatorsfor overheaddistribution linesLithiumbattery power
PE
9071
9
PE
9072
0
PE
9072
1
PE
9072
2
PE
9072
3
PE
9072
4
PE
9072
5
PE
9072
6
Panorama for MV distribution networks www.schneider-electric.com14
Control & MonitoringProtection & control relays
PM
1027
03
PE
8803
0
PE
8802
2
PE
8802
3
PE
8802
4
PM
1005
02
PM
1005
22
PM
1005
27
Protection
Sepamseries 10
Sepamseries 20
Sepamseries 40
Sepamseries 60
Sepamseries 80
MiCOMseries 10
MiCOMseries 20
MiCOMseries 30
MiCOMseries 40
VAMP
Protection relay for basic applications
Protection relay for standard applications
Multi-functionprotection relay for demandingapplications
Multi-functionprotection relay forhigh-performanceapplications
Multi-functionprotection unit forcritical and customisedapplications
Protection relaysfor basic electricalschemes
Protection relays for standard electricalschemes
Multi-functionprotection relays forcomplex electricalschemes
Multi-functionprotection relays for complex electricalschemes
Dedicated ArcProtection Schemes
Secondary PowerDistribution Networks
Utility MV andIndustrial DistributionNetworks
Utility MV andIndustrial DistributionNetworks
Utility MV andIndustrial DistributionNetworks
Utility MV, Generationand Industrial DistributionNetworks
MV Industrial andBuilding Networks,Secondary andPrimary DistributionNetworks
Primary Distribution,MV Substations and Industrial Networks
Industrial Networks,Railways and Utility MV, HV Substations
Industrial Networks,Generation and UtilityMV, HV Substations
FeederTransformer
FeederBusbarTransformerMotor
FeederGeneratorTransformerMotor
FeederGeneratorTransformerMotorCapacitor
FeederBusbarTransformerMotorGeneratorCapacitor
FeederMotor
FeederMotorBusbarLine Differential
FeederMotorTransformerLine DifferentialDistanceRail
FeederMotorTransformerLine DifferentialDistanceBusbarGeneration
Arc ProtectionCommunication Protocol
Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Modbus RTUDNP3IEC 60870-5-103Modbus TCP/IP
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTU,IEC 60870-5-103
Modbus RTUDNP3IEC 60870-5-103Courier
Modbus RTUDNP3IEC 60870-5-101IEC 60870-5-103CourierIEC 61850
Modbus RTUDNP3IEC 60870-5-103CourierIEC 61850
Modbus RTUModbus TCPIEC 61850DNP3 TCPProfibusIEC 60870-5-101IEC 60870-5-103
Panel Panel Panel Panel Panel Wall/Surface,Panel or DIN Rail
Panel or Rack(with adaptor)
Panel, Wall/Surface or Rack
Panel or Rack Panel or DIN Rail
Panorama for MV distribution networks 15
Control & MonitoringProtection & control relays
PM
1005
26
PM
1035
32Protection
Sepamseries 10
Sepamseries 20
Sepamseries 40
Sepamseries 60
Sepamseries 80
MiCOMseries 10
MiCOMseries 20
MiCOMseries 30
MiCOMseries 40
VAMP
Protection relay for basic applications
Protection relay for standard applications
Multi-functionprotection relay for demandingapplications
Multi-functionprotection relay forhigh-performanceapplications
Multi-functionprotection unit forcritical and customisedapplications
Protection relaysfor basic electricalschemes
Protection relays for standard electricalschemes
Multi-functionprotection relays forcomplex electricalschemes
Multi-functionprotection relays for complex electricalschemes
Dedicated ArcProtection Schemes
Secondary PowerDistribution Networks
Utility MV andIndustrial DistributionNetworks
Utility MV andIndustrial DistributionNetworks
Utility MV andIndustrial DistributionNetworks
Utility MV, Generationand Industrial DistributionNetworks
MV Industrial andBuilding Networks,Secondary andPrimary DistributionNetworks
Primary Distribution,MV Substations and Industrial Networks
Industrial Networks,Railways and Utility MV, HV Substations
Industrial Networks,Generation and UtilityMV, HV Substations
FeederTransformer
FeederBusbarTransformerMotor
FeederGeneratorTransformerMotor
FeederGeneratorTransformerMotorCapacitor
FeederBusbarTransformerMotorGeneratorCapacitor
FeederMotor
FeederMotorBusbarLine Differential
FeederMotorTransformerLine DifferentialDistanceRail
FeederMotorTransformerLine DifferentialDistanceBusbarGeneration
Arc ProtectionCommunication Protocol
Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Modbus RTUDNP3IEC 60870-5-103Modbus TCP/IP
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850
Modbus RTU,IEC 60870-5-103
Modbus RTUDNP3IEC 60870-5-103Courier
Modbus RTUDNP3IEC 60870-5-101IEC 60870-5-103CourierIEC 61850
Modbus RTUDNP3IEC 60870-5-103CourierIEC 61850
Modbus RTUModbus TCPIEC 61850DNP3 TCPProfibusIEC 60870-5-101IEC 60870-5-103
Panel Panel Panel Panel Panel Wall/Surface,Panel or DIN Rail
Panel or Rack(with adaptor)
Panel, Wall/Surface or Rack
Panel or Rack Panel or DIN Rail
Panorama for MV distribution networks www.schneider-electric.com16
Oil Immersed Distribution Transformers
Oil Immersed Medium Power Transformers
Dry type Transformers Special Transformers
MINERA ODT Pole and ground mounted
MINERA MP TRIHAL SPT
Oil immersed type Dry type
Rated voltage (kV)
Power ratings
From 25 kVA up to 3.15 MVA > 3.15 up to 80 MVA From 100 kVA up to 15 MVA Up to 80 MVA Up to 30 MVA
Frequency
50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz
Dielectric
Mineral Oil – IEC60296L ClassFire resistant oil (Vegeta)K Class (K2 - K3)
Mineral Oil – IEC60296L ClassFire resistant oil (Vegeta)K Class (K2 - K3)
Cast Resin encapsulated Certified C3* E3 F1
Custom solutions. Special applications - Compact Minera Siltrim- Minera EX (Zone 1 and 2)- Photovoltaic Minera PV- Compact Minera PAD- Full cast Tricast- Furnace transformer- Rectifier transformer- Generator transformers- Motor starting reactors- Others upon request- IP54, IP55 Dry Type Outdoor Transformers - Auto transformers- Single Phase Transformers- Self Protected Transformer- Dry Type Transformer with OLTC
Optimized efficiency
Standard lossesHigh Efficiency (Minera HE & HE+)
Standard lossesHigh Efficiency (Minera HE & HE+)
Standard lossesHigh Efficiency (Trihal HE)
Cooling system
ONAN – Natural airONAF – Air forced (up to 40%)
ONAN, ONAF, ODAF, ODWF or OFAF
AN - Natural airANAF / AF – Air forced (up to +40%)
Tank / Enclosure types
Hermetically sealedBreathing type
Hermetically sealed, gas cushion transformersFree-breathing with expansion tank
Common Design – Indoor useIP21, IP31, IP23Custom Enclosure – Outdoor useIP35, IP44
3652
36
PE
9073
2
Medium Voltage TransformersOil Immersed Distribution Transformers
Medium Power Transformers
Dry type Transformers
Special transformers
170 170
PE
9073
3
PE
9073
4
PE
9075
0
PE
9074
9
PE
9073
5
Panorama for MV distribution networks 17
Medium Voltage TransformersOil Immersed Distribution Transformers
Medium Power Transformers
Dry type Transformers
Special transformers
Power Factor Correction
Power Factor Correction
Propivar NG CP 200 series
IEC IEC
Rated voltage (kV)
Max. rated current
900 kVAR 14400 kVAR
Max. rated short circuit current
31.5 kA
"All film"with or withoutinternal fuses
Vacuum / SF6
Power factorcorrection onMV networksor devices
Power factorcorrection andharmonic filteringon MV networks
Fixed or automaticcapacitor banks for motor, substation,or globaldistribution
Indoor or outdoorinstallation
36 36
PB
1081
51
PE
9072
7
Panorama for MV distribution networks www.schneider-electric.com18
Medium Voltage / Low Voltage Prefabricated Substations (PSS)
Standard Substations - Integrated Standard Substations - Compact Standard Substations - Walk-in Customized substations
Specific substations (PSS) Prefabricated Substations Electrical House (E-House) Mobile substations Trackside substations
MV Switching kiosk MV/LV external operations MV/LV internal operations MV/LV Underground All voltage levels MV All voltage levels All voltage levels
IEC BS IEC / AS / HN IEC / AS / HN IEC / HN IEC IEC, HNBuilding codes: Eurocodes (according to specific type of substations)
IEC, AS, BS, ANSI/NEMA...
Building codes: Eurocodes, IBC, BCA
IEC, AS, BS, ANSI/NEMA...
Building codes: Eurocodes, IBC, BCA
Rated voltage (kV) Rated voltage (kV)
Transformer maximum power (kVA) Transformer maximum power (kVA)
Non applicable / without transformer
MV switchgearAutomationRTUUPS
MV switchgearMV MCCLV switchgearLV MCC, VSD,...AutomationUPSRTU,...
10MVA transformerHV/MV switchgearon & off-load tapchangers blackstart genset, UPSRTU & Sat ComCable reel
MV switchgearAutomationUPSRTU
Enclosure material Enclosure material
Without (frame mounted) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Truck mounted ■
Mode of operation Mode of operation
Indoor Indoor / Outdoor Outdoor Outdoor Indoor Indoor Indoor These substations offer modularity of their dimensions to respond to all equipmentrequirements
These substations offer modularity of their dimensions to respond to all equipmentrequirements
Complete stand-alone substation permanently mounted on a standard semi trailer to offer full mobility at highway speed without escort
These substations offer modularity of their dimensions to respond to all equipmentrequirements
Description Description
The MV and LV equipment are delivered directly mounted ensuring a safety, and fast solution. They can be installed in existing building, in a substation or outdoor*
*BS version
Outdoor operations type of substation allows reduce footprint and speed of installation. Internal equipment arrangement can be fitted to any type of access
Indoor operation provides to operator protection against bad weather and better working conditions. It offers fast delivery, safety and quick erection versus traditional construction. MV/LV Underground substations are invisible and fully integrated into the environment, allowing space saving whilst maintaining a high level of safety
These tailor made substations offer modularity of their dimensions to respond to all equipment requirements
Pre-fabricated primary substation complete withits ancillary equipment ready to be shipped,allowing minimal site work
Pre-fabricated substationcomprising primary supply and processcontrol switchgear,complete with ancillary equipment ready to be shipped, allowing minimal site work
Emergency power supply to back-up any HV/MVtransformer within a Utility network in less than 4 hours
Electrical supply ofcatenaries for main lines,high speed lines or freightlines
Application Application
DistributionBuidings
Distribution, industry, buidings
Distribution, buildings Distribution, industry, wind, buildings
Distribution, industry, wind, buildings
Distribution, buildings Primary and Secondary distributions, Large industries, Oil & Gas, Mine & Metal, Solar & Wind
Primary distribution,Large industriesOil & GasMining & MetalsSolar & Wind
Oil & Gas - Upstream, midstream, downstreamUtilities - HV/MV substationsMining & MetalsEnergy - Intensive industriesUtilities - Primary or reflection substationsRailways - Trackside substations
Primary distribution RailwaysMining & Metals
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Protection and reconfiguration of the MV undergrounded network.Equipped with MV Ring Main Units switchgears. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent)*. Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
*Non applicable to underground substations
■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete ■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete
36
2000
36
PE
9073
7
PE
9073
817.5
2000
630
36
PE
9073
9
PE
9074
0
1250
36 36
PM
1023
82
1 x1000 2 x
630
PE
9074
1
Panorama for MV distribution networks 19
Medium Voltage / Low Voltage Prefabricated Substations (PSS)
Standard Substations - Integrated Standard Substations - Compact Standard Substations - Walk-in Customized substations
Specific substations (PSS) Prefabricated Substations Electrical House (E-House) Mobile substations Trackside substations
MV Switching kiosk MV/LV external operations MV/LV internal operations MV/LV Underground All voltage levels MV All voltage levels All voltage levels
IEC BS IEC / AS / HN IEC / AS / HN IEC / HN IEC IEC, HNBuilding codes: Eurocodes (according to specific type of substations)
IEC, AS, BS, ANSI/NEMA...
Building codes: Eurocodes, IBC, BCA
IEC, AS, BS, ANSI/NEMA...
Building codes: Eurocodes, IBC, BCA
Rated voltage (kV) Rated voltage (kV)
Transformer maximum power (kVA) Transformer maximum power (kVA)
Non applicable / without transformer
MV switchgearAutomationRTUUPS
MV switchgearMV MCCLV switchgearLV MCC, VSD,...AutomationUPSRTU,...
10MVA transformerHV/MV switchgearon & off-load tapchangers blackstart genset, UPSRTU & Sat ComCable reel
MV switchgearAutomationUPSRTU
Enclosure material Enclosure material
Without (frame mounted) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Truck mounted ■
Mode of operation Mode of operation
Indoor Indoor / Outdoor Outdoor Outdoor Indoor Indoor Indoor These substations offer modularity of their dimensions to respond to all equipmentrequirements
These substations offer modularity of their dimensions to respond to all equipmentrequirements
Complete stand-alone substation permanently mounted on a standard semi trailer to offer full mobility at highway speed without escort
These substations offer modularity of their dimensions to respond to all equipmentrequirements
Description Description
The MV and LV equipment are delivered directly mounted ensuring a safety, and fast solution. They can be installed in existing building, in a substation or outdoor*
*BS version
Outdoor operations type of substation allows reduce footprint and speed of installation. Internal equipment arrangement can be fitted to any type of access
Indoor operation provides to operator protection against bad weather and better working conditions. It offers fast delivery, safety and quick erection versus traditional construction. MV/LV Underground substations are invisible and fully integrated into the environment, allowing space saving whilst maintaining a high level of safety
These tailor made substations offer modularity of their dimensions to respond to all equipment requirements
Pre-fabricated primary substation complete withits ancillary equipment ready to be shipped,allowing minimal site work
Pre-fabricated substationcomprising primary supply and processcontrol switchgear,complete with ancillary equipment ready to be shipped, allowing minimal site work
Emergency power supply to back-up any HV/MVtransformer within a Utility network in less than 4 hours
Electrical supply ofcatenaries for main lines,high speed lines or freightlines
Application Application
DistributionBuidings
Distribution, industry, buidings
Distribution, buildings Distribution, industry, wind, buildings
Distribution, industry, wind, buildings
Distribution, buildings Primary and Secondary distributions, Large industries, Oil & Gas, Mine & Metal, Solar & Wind
Primary distribution,Large industriesOil & GasMining & MetalsSolar & Wind
Oil & Gas - Upstream, midstream, downstreamUtilities - HV/MV substationsMining & MetalsEnergy - Intensive industriesUtilities - Primary or reflection substationsRailways - Trackside substations
Primary distribution RailwaysMining & Metals
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Protection and reconfiguration of the MV undergrounded network.Equipped with MV Ring Main Units switchgears. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent)*. Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200
*Non applicable to underground substations
■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete ■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete
PM
1028
35
PE
9031
3
PE
9032
5
PE
9073
6
PE
9031
7
40.5
15
3150
36 27.5
up to 72
up to 72
2 x27.5
Panorama for MV distribution networks www.schneider-electric.com2020 Panorama for MV distribution networks www.schneider-electric.com
Electrical Distribution Services
Comprehensive Electrical Installation Services from Schneider Electric
Your ElectricalDistribution Equipment
Greater Productivity,Reliability, andSafety
Electrical Distribution Services
Panorama for MV distribution networks 21Panorama for MV distribution networks 21
Electrical Distribution Services
Comprehensive Installed Base Services
Renew
PlanO
ptim
ize
Operate
Install
How do I renew mysolution?
What aremy options?
How do Iinstall andcommission?
How do Ioptimize?
How do Ioperate andmaintain?
AssetManagement
Life Cycle
Renew- ECOFIT™ - Modernization solutions - Infrastructure enhancement Plan
- Technical Feasability studies - Architecture & Design studies- Facility assessment
Install- Project management - Site coordination - Assembly & Start-up commissioningOperate
- Warranty Extensions/ Service Plans- Expert Technical support- Preventive / Predictive Maintenance- Spare Parts management- Technical Training
Optimize- Remote Monitoring
Services - Maintenance consulting - On-Site energy,
reliability- Safety assessment
Peace of mind for every stage of the lifecycle
Schneider Electric Korea Ltd. 슈나이더 일렉트릭 코리아(주)
NRJE
D11
1210
EN ⓒ
2014
Sch
neid
er Ele
ctric
. All
Rig
hts
Rese
rved. All
trad
em
arks
are
ow
ned b
y Sch
neid
er Ele
ctric
Indus
trie
s SAS o
r its
alia
ted c
om
pan
ies.
서울본사 부산지사 대구지사 대전지사 천안지사
서울 마포구 성암로 189 부산시 사상구 대구 북구 산격2동 대전 유성구 관평동 충남 천안시 서북구
중소기업 DMC타워 괘법동 559-13 1666 전기조명관 1342 디티비안 불당동 724
동훈빌딩 5층 크리스탈빌딩 401호 오피스텔 A동 836호 C&J빌딩 903호
Tel. 02 2630 9700 Tel. 051 319 7901 Tel. 053 604 6028 Tel. 042 822 3240 Tel. 041 552 0501
Fax 02 2630 9800~1 Fax 051 319 7900 Fax 053 604 6029 Fax 042 822 3241 Fax 041 552 0599
03/2014
This is only a summary of the product features and is for reference purpose only. The information herein is provided to you "AS IS" AND WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR
NON-INFRINGEMENT. While the information provided is believed to be accurate, it may include errors or inaccuracies; we assume no liability for errors or omissions in the content
of the information nor do we accept any liability as a result of reliance upon the information contained herein. In no event shall we be liable to any person for any special, indirect or
consequential damages relating to this material, unless caused by gross negligence or intentional misconduct.
모바일웹 페이스북
고객센터 : 1588-2630
웹사이트 : www.schneider-electric.co.kr
카 페 : www.energyforum.co.kr
트 위 터 : twitter.com/SchneiderKorea
블 로 그 : www.sch-log.com
페이스북 : www.facebook.com/SchneiderElectric
www.MyEnergyUniversity.co.kr 사이트에 키코드 43633y를 등록하시면 에너지 효율
향상 교육을 무료로 수강하실 수 있습니다. 지금 방문하시고 에너지 효율 챔피언이 되십시오!