Products and equipment for Medium Voltage distribution ...

24
Discovering our offer at a glance Products and equipment for Medium Voltage distribution networks 2014

Transcript of Products and equipment for Medium Voltage distribution ...

Discovering our offer at a glanceProducts and equipment forMedium Voltage distribution networks 2014

Prod

ucts

and

equ

ipm

ent f

or M

ediu

m V

olta

gedi

strib

utio

n ne

twor

ks

Medium Voltage Circuit Breakers & Contactors 1

Indoor Circuit Breakers 1

Indoor Contactors 3

Outdoor Circuit Breakers 3

Medium Voltage Switchgear 4

Air-Insulated Switchgear (AIS) for Primary Distribution 4

Motor Control 5

Air-Insulated Switchgear (AIS) for Secondary Distribution 5

Gas-Insulated Switchgear (GIS) for Primary Distribution 6

Gas-Insulated Ring Main Units for Secondary Distribution 7

Shielded Solid Insulation System 8

Medium Voltage Fuses 8

Medium Voltage Instrument Transformers 9

Medium Voltage Disconnectors, Switches, Switch-Disconnections, Reclosers

10

Indoor Switch-Disconnectors 10

Pole-Mounted Switchgears 10

Control & Monitoring 12

Medium Voltage components for switchgear control 12

Feeder Automation 12

Remote monitoring and control 13

Protection & control relays 14

Medium Voltage Transformers 16

Oil Immersed Distribution Transformers 16

Oil Immersed Medium Power Transformers 16

Dry type Transformers 16

Special Transformers 16

Power Factor Correction 17

Medium Voltage / Low Voltage prefabricated Substations (PSS)

18

Standard Substations - Integrated 18

Standard Substations - Compact 18

Standard Substations - Walk-In 18

Customized substations 19

Electrical Distribution Services 20

Panorama for MV distribution networks 1

Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers

Indoor Circuit Breakers

LF LFP SF1 SF400 SF2 Evolis 17.5 kV Evolis 24 kV

IEC IEC IEC IEC IEC IEC IEC

Rated voltage (kV)

Max. rated current

3150 A 5000 A 1250 A 2500 A 1250 A 3150 A 2500 A 2500 A 1250 A 2500 A

Max. rated short circuit current

50 kA 40 kA 50 kA 31.5 kA 25 kA 40 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 25 kA 31.5 kA

SF6 SF6 SF6 SF6 SF6 Vacuum Vacuum

Fixedor withdrawableCircuit Breaker

Fixed Circuit Breaker

High power versionfor power pant

Fixed Circuit Breaker

Front or side mountingConventional spring

Integrated VIP trip unit(without auxiliary powersupply) in SFset up to 24 kV(for side mounted)

Suited for capacitor bankapplication

Withdrawable Circuit Breaker

Front mounted

Fixed Circuit Breaker

Front mounted

Fixed orwithdrawable Circuit Breaker

Fixed CircuitBreaker

Sidemounted

VIPintegratedtrip unit

Fixed orwith-drawableCircuit Breaker

Frontmounted

36 36 36

24 24

12 12 1212

17.5 17.5 17.517.5

40.5 40.5

PE

5719

1

PE

9023

0

PE

9023

2

PE

5650

1

PE

5799

4

PE

5800

1

PE

5650

2

Panorama for MV distribution networks www.schneider-electric.com2

Indoor Circuit Breakers Indoor Contactors Outdoor Circuit Breakers

Cradle/Cassette Railway

HVX HVX embedded pole VR VAH VXC ISF2 PMX cradle NEX cradle VXA-VXB Rollarc CBX CLX CPX FVR VOX

IEC/ANSI/GB (Chinese)/GOST standards

GB (Chinese)standards

GB (Chinese)GOST standards

ANSI IEC/ANSI/IEEE IEC IEC EC IEC/GB IEC/ANSI IEC IEC IEC IEC ANSI IEC / ANSI /EATS / GOST

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

2500 A 2500 A* 3150 A 2500 A 2500 A 3000 A 2750 A 8000 A 2500 A 4000 A 3150 A 3150 A 2500 A 2000 A 2500 A 400 A (AC4) 400 A (AC4)

315 A (AC4)

400 A (AC4) 400 A (AC4) 2000 A 2000 A

Max. rated short circuit current Max. rated short circuit current

50 kA 31,5 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 63 kA 40 kA 63 kA* 31.5 kA 40 kA 40 kA 40 kA 31.5 kA 25 kA 40 kA 10 kA 8 kA 6 kA* 4 kA* 6 kA 4 kA 12.5 - 40 kA

12.5 - 25 kA

12.5 - 31.5 kA

40 kA

Vacuum Vacuum Vacuum Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum Vacuum Vacuum / SF6

Fixed or withdrawable Circuit Breaker

* 3150A performance is possible. Please contact us

Fixed or withdrawable Circuit Breaker

Embedded pole for better dielectricand environmental pollution withstand

Withdrawable Fixed orwithdrawableCircuit Breaker.

For generatorapplicationsup to 130 MVA.

* ANSI / IEEEC37.013GeneratorSwitching63 kA, 4000 &5000 A

Fixed orwithdrawableCircuit Breaker.

The arc furnaceCircuit Breakerwith high switchingnumbers,maintenancefree up to25,000/75,000cycles.

Fixed CircuitBreaker forelectrical arcfurnace

Craddlebased onPIXswitchgear

Craddle based on NEXswitchgear

1 or 2-pole circuitbreakerfor railwayapplication or asstar point breakerfor groundingapplication

Fix installation orfloor running truck

- 16 2/3 Hz- 25 Hz- 50Hz- 60 Hz

Fixed or withdrawablecontactor withmagnetic holding ormechanical

Fixed vacuumcontactorIn versionwithdrawable fusedvacuum contactor:CVX

*(50kA in conjunctionwith fuses)

1 or 3 poles

With magnetic holdingor mechanical

Fixed vacuumcontactorwith magneticholding ormechanical

Fixedvacuumcontactorwithmagneticholding ormechanical

Station breaker: fixed outdoor Dead TankCircuit Breaker

Fixed outdoorDead Tank CircuitBreaker

Indoor

24 2427

24

36 36 3638

40.5

17.5 17.5

12 12

15

PE

9023

4

DE

9021

7

PE

9023

6

PM

1026

99

PE

9023

9

PE

9023

8

PE

9024

1

PE

9033

9

Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers

Indoor Contactors

Outdoor Circuit Breakers

Panorama for MV distribution networks 3

Indoor Circuit Breakers Indoor Contactors Outdoor Circuit Breakers

Cradle/Cassette Railway

HVX HVX embedded pole VR VAH VXC ISF2 PMX cradle NEX cradle VXA-VXB Rollarc CBX CLX CPX FVR VOX

IEC/ANSI/GB (Chinese)/GOST standards

GB (Chinese)standards

GB (Chinese)GOST standards

ANSI IEC/ANSI/IEEE IEC IEC EC IEC/GB IEC/ANSI IEC IEC IEC IEC ANSI IEC / ANSI /EATS / GOST

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

2500 A 2500 A* 3150 A 2500 A 2500 A 3000 A 2750 A 8000 A 2500 A 4000 A 3150 A 3150 A 2500 A 2000 A 2500 A 400 A (AC4) 400 A (AC4)

315 A (AC4)

400 A (AC4) 400 A (AC4) 2000 A 2000 A

Max. rated short circuit current Max. rated short circuit current

50 kA 31,5 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 63 kA 40 kA 63 kA* 31.5 kA 40 kA 40 kA 40 kA 31.5 kA 25 kA 40 kA 10 kA 8 kA 6 kA* 4 kA* 6 kA 4 kA 12.5 - 40 kA

12.5 - 25 kA

12.5 - 31.5 kA

40 kA

Vacuum Vacuum Vacuum Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 Vacuum Vacuum Vacuum Vacuum Vacuum / SF6

Fixed or withdrawable Circuit Breaker

* 3150A performance is possible. Please contact us

Fixed or withdrawable Circuit Breaker

Embedded pole for better dielectricand environmental pollution withstand

Withdrawable Fixed orwithdrawableCircuit Breaker.

For generatorapplicationsup to 130 MVA.

* ANSI / IEEEC37.013GeneratorSwitching63 kA, 4000 &5000 A

Fixed orwithdrawableCircuit Breaker.

The arc furnaceCircuit Breakerwith high switchingnumbers,maintenancefree up to25,000/75,000cycles.

Fixed CircuitBreaker forelectrical arcfurnace

Craddlebased onPIXswitchgear

Craddle based on NEXswitchgear

1 or 2-pole circuitbreakerfor railwayapplication or asstar point breakerfor groundingapplication

Fix installation orfloor running truck

- 16 2/3 Hz- 25 Hz- 50Hz- 60 Hz

Fixed or withdrawablecontactor withmagnetic holding ormechanical

Fixed vacuumcontactorIn versionwithdrawable fusedvacuum contactor:CVX

*(50kA in conjunctionwith fuses)

1 or 3 poles

With magnetic holdingor mechanical

Fixed vacuumcontactorwith magneticholding ormechanical

Fixedvacuumcontactorwithmagneticholding ormechanical

Station breaker: fixed outdoor Dead TankCircuit Breaker

Fixed outdoorDead Tank CircuitBreaker

Indoor

24 2517.5

7.2 7.2 7.212 12

DS

CF2

305

PE

6024

7

PM

1037

84

Medium Voltage Circuit Breakers & ContactorsIndoor Circuit Breakers

Indoor Contactors

Outdoor Circuit Breakers

PE

9028

4

3.6

PM

1037

87

15

27

38 38

PE

9025

0

PE

9025

0

PM

1037

89

Panorama for MV distribution networks www.schneider-electric.com4

AIS for Primary Distribution Motor Control AIS for Secondary Distribution

Air Insulated Switchgear up to 24 kV Railway

MCset PIX PIX Double Busbar

PIX High NEX GenieEvo DNF7 F400 Masterclad PIX DC Motorpact PIX MCC SM6-24 SM6-36 HVL HVL/cc

IEC IEC/GOST

IEC IEC/GOST IEC/GB IEC IEC IEC IEC/GB/GOST IEC / GOST ANSI/UL IEC/EN IEC/NEMA IEC IEC IEC ANSI ANSI

Rated voltage (kV) Rated voltage (kV)

LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2A-PI LSC2B-PM LSC2A-PI LSC 2B-PM

Max. rated current Max. rated current

4000 A 2500 A 4000 A 2500 A 3150 A 5000 A 2500 A 2500 A 2000 A 2000 A 2000 A (SF CB)2500 A (Vacuum CB). For 3150 A, please consult us.

2500 A 1250 A 4000 A 2750 A 4000 A 3150 A 5000 A (busbars) 630 A & 1250A 630 A 1250 A 1200 A 1200 A

LSC2B-PM 400 A contactor

Max. rated short circuit current Max. rated short circuit current

50 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 50 kA 31.5 kA 31.5 kA 25 kA 25 kA 31.5 kA 40 kA 31.5 kA 63 kA 40 kA 50 kA 50 kA 25 kA 20 kA 25 kA 20 to 61 kA 32 kA 40 kA

Vacuum*SF6

SF6 Vacuum* Vacuum Vacuum Vacuum Vacuum Vacuum / SF6 SF6 Vacuum Air Vacuum Vacuum SF6Vacuum CB

SF6 CB Open-air switch SF6 switch

Single busbar system,Withdrawable CircuitBreaker

* Limited 31.5 kA / 2000A. Above, please consult us.

Single busbarsystem,WithdrawableCircuit Breaker

* SF6 technology, please refer to MCset

Double busbar system,WithdrawableCircuit Breaker

Single busbarsystemWithdrawableCircuit Breaker

Single busbar systemWithdrawable VaccumCircuit Breaker

Single busbarsystemFixed typeRear cableaccess

Single busbarsystem

* up to48 kV/20 kA

Single busbarsystem

Single busbar system

For light railwaysegment(tram/metro)

Width 650 mm

Withdrawabledouble busbarfor S3DOLRVSSRVATReversing 2-speed

WithdrawableDirect line-upwith PIXFront accesscabling(rear option)DOL and feederapplications

Complete system of modular cubicles

Complete system of modular cubicles

Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available

Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available

Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor & Outdoor Indoor & Outdoor NEMA

Indoor Indoor Indoor

IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC

40.5

121213.8

17.517.517.517.5 17.52424 24

PE

5746

6

DM

1021

84

Medium Voltage SwitchgearsAir-Insulated Switchgear (AIS) for Primary Distribution

Motor Control

Air-Insulated Switchgear (AIS) for Secondary Distribution

PM

1035

75

PM

1028

25

PE

9020

8

PM

1030

10

PE

9027

2

PE

9027

1

36

40.5

Panorama for MV distribution networks 5

AIS for Primary Distribution Motor Control AIS for Secondary Distribution

Air Insulated Switchgear up to 24 kV Railway

MCset PIX PIX Double Busbar

PIX High NEX GenieEvo DNF7 F400 Masterclad PIX DC Motorpact PIX MCC SM6-24 SM6-36 HVL HVL/cc

IEC IEC/GOST

IEC IEC/GOST IEC/GB IEC IEC IEC IEC/GB/GOST IEC / GOST ANSI/UL IEC/EN IEC/NEMA IEC IEC IEC ANSI ANSI

Rated voltage (kV) Rated voltage (kV)

LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2B PM LSC 2A-PI LSC2B-PM LSC2A-PI LSC 2B-PM

Max. rated current Max. rated current

4000 A 2500 A 4000 A 2500 A 3150 A 5000 A 2500 A 2500 A 2000 A 2000 A 2000 A (SF CB)2500 A (Vacuum CB). For 3150 A, please consult us.

2500 A 1250 A 4000 A 2750 A 4000 A 3150 A 5000 A (busbars) 630 A & 1250A 630 A 1250 A 1200 A 1200 A

LSC2B-PM 400 A contactor

Max. rated short circuit current Max. rated short circuit current

50 kA 31.5 kA 40 kA 31.5 kA 31.5 kA 50 kA 31.5 kA 31.5 kA 25 kA 25 kA 31.5 kA 40 kA 31.5 kA 63 kA 40 kA 50 kA 50 kA 25 kA 20 kA 25 kA 20 to 61 kA 32 kA 40 kA

Vacuum*SF6

SF6 Vacuum* Vacuum Vacuum Vacuum Vacuum Vacuum / SF6 SF6 Vacuum Air Vacuum Vacuum SF6Vacuum CB

SF6 CB Open-air switch SF6 switch

Single busbar system,Withdrawable CircuitBreaker

* Limited 31.5 kA / 2000A. Above, please consult us.

Single busbarsystem,WithdrawableCircuit Breaker

* SF6 technology, please refer to MCset

Double busbar system,WithdrawableCircuit Breaker

Single busbarsystemWithdrawableCircuit Breaker

Single busbar systemWithdrawable VaccumCircuit Breaker

Single busbarsystemFixed typeRear cableaccess

Single busbarsystem

* up to48 kV/20 kA

Single busbarsystem

Single busbar system

For light railwaysegment(tram/metro)

Width 650 mm

Withdrawabledouble busbarfor S3DOLRVSSRVATReversing 2-speed

WithdrawableDirect line-upwith PIXFront accesscabling(rear option)DOL and feederapplications

Complete system of modular cubicles

Complete system of modular cubicles

Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available

Fusible and non-fusible designs, over toggle, stored energy and motor-operated mechanisms available

Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor & Outdoor Indoor & Outdoor NEMA

Indoor Indoor Indoor

IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC

Medium Voltage SwitchgearsAir-Insulated Switchgear (AIS) for Primary Distribution

Motor Control

Air-Insulated Switchgear (AIS) for Secondary Distribution

PE

9027

6

15

27

0.75 1.5

PE

9029

1

7.2 7.2

PE

9026

6

PM

1030

07

PE

9069

8

PE

9069

9

PE

9070

0

PE

9070

1

24

12

3638 38

Panorama for MV distribution networks www.schneider-electric.com6

Medium Voltage SwitchgearsGas-Insulated Switchgear (GIS) for Primary Distribution

Gas-Insulated Ring Main Units for Secondary Distribution

Gas-Insulated Switchgear (GIS) for Primary Distribution Gas-Insulated Ring Main Units for Secondary Distribution

Railway

GMA CBGS-0 WS GHA CBGS 2 WI GHA Rail WI Rail CBGS-0 CBGS-2 Ringmaster FBX RM6 DVCAS Flusarc

IEC / GOST /CNS

IEC/ANSI (UL) IEC / GOST /CNS

IEC / GOST /CNS

IEC IEC / GOST /CNS

IEC/GB (China) IEC/EN IEC IEC IEC IEC IEC IEC/ANSI/UL IEC

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

2500 A 2000 A 2000 A 2500 A 2500 A 2000 A 2500 A 2000 A 2000 A 1250 A 2000 A 630 A 630 A 630 A 630 A 630 A 630 A

option busbar1250A

Max. rated short circuit current Max. rated short circuit current

31.5 kA 31.5 kA 31.5 kA 40 kA 25 kA 40 kA 25 kA 31.5 kA 25 kA 25 kA 21 kA 25 kA 21 kA 25 kA 20 kA 20 kA 25 kA

Vacuum SF6 Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 SF6 SF6 CBSF6 LBS

Vacuum CBSF6 LBS

SF6 CBSF6 LBS

Vacuum CBSF6 LBS

Vacuum CBSF6 LBS

Single busbarsystemFixed typeMainly with C.B.but also switch-disconnectorfunctionsLess Space-MorePower verycompact designFlexible busbarsystemOuter cone cableconnectionNo gas handling

Single busbar systemFixed typeMainly with C.B. but also switch-disconnectorfunctions

Compact design at 36kVFlexible busbarsystemOuter cone cableconnectionNo gas handling

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Same smallfootprint forSBB and DBB,spacious cableconnection innercone

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Compact design,flexible cableconnection forouter cone andinner cone, nogas handling

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Spacious cableconnection innercone

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar.

Same small foot-print for SBB andDBB, spaciouscable connectioninner cone

Single busbarsystemFixed typeFor tractionapplication1 or 2 polesolution

BIL 200 kV,suitablefor traction sidecontainerSubstationNo gas handling

Single busbarsystemFixed typeFor tractionapplication,1 or 2 polesolution

BIL 250 kV,suiteable fortraction sidecontainerSubstation

For railwayapplication 1 pole(170kV BIL)

For railwayapplication 1 or 2poles (250kV BIL)Single busbarsystemFixed typeFor tractionapplication, 1 or 2pole solution

BIL 250 kV,suiteable fortraction sidecontainerSubstation

Compact and modularswitchgearcombining all MV functional units

Compact and modularswitchgear combining all MV functional units

Compactand modularswitchgearcombining all MVfunctional units

Wind dedicatedmodular switchgearcombiningall MV functionalunits used in windfarms

Compact and modularswitchgear combiningall MV functional units

Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor andoutdoor

Indoor Indoor Indoor Indoor & Outdoor

Indoor

IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC

24

36 36

52 5240.5

38

PM

1030

68

PM

1028

31

PM

1028

33

PE

9069

7

PM

1030

08

PM

1028

34

PE

9070

5

PM

1027

06

2 x 27.5

2 x 27.5

1 x 27.5

1 x 27.5

Panorama for MV distribution networks 7

Medium Voltage SwitchgearsGas-Insulated Switchgear (GIS) for Primary Distribution

Gas-Insulated Ring Main Units for Secondary Distribution

Gas-Insulated Switchgear (GIS) for Primary Distribution Gas-Insulated Ring Main Units for Secondary Distribution

Railway

GMA CBGS-0 WS GHA CBGS 2 WI GHA Rail WI Rail CBGS-0 CBGS-2 Ringmaster FBX RM6 DVCAS Flusarc

IEC / GOST /CNS

IEC/ANSI (UL) IEC / GOST /CNS

IEC / GOST /CNS

IEC IEC / GOST /CNS

IEC/GB (China) IEC/EN IEC IEC IEC IEC IEC IEC/ANSI/UL IEC

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

2500 A 2000 A 2000 A 2500 A 2500 A 2000 A 2500 A 2000 A 2000 A 1250 A 2000 A 630 A 630 A 630 A 630 A 630 A 630 A

option busbar1250A

Max. rated short circuit current Max. rated short circuit current

31.5 kA 31.5 kA 31.5 kA 40 kA 25 kA 40 kA 25 kA 31.5 kA 25 kA 25 kA 21 kA 25 kA 21 kA 25 kA 20 kA 20 kA 25 kA

Vacuum SF6 Vacuum Vacuum SF6 Vacuum Vacuum Vacuum SF6 SF6 SF6 CBSF6 LBS

Vacuum CBSF6 LBS

SF6 CBSF6 LBS

Vacuum CBSF6 LBS

Vacuum CBSF6 LBS

Single busbarsystemFixed typeMainly with C.B.but also switch-disconnectorfunctionsLess Space-MorePower verycompact designFlexible busbarsystemOuter cone cableconnectionNo gas handling

Single busbar systemFixed typeMainly with C.B. but also switch-disconnectorfunctions

Compact design at 36kVFlexible busbarsystemOuter cone cableconnectionNo gas handling

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Same smallfootprint forSBB and DBB,spacious cableconnection innercone

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Compact design,flexible cableconnection forouter cone andinner cone, nogas handling

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar

Spacious cableconnection innercone

Single and doublebusbar systemFixed typeCB applications

Separated gas-compartmentsfor CB and busbar.

Same small foot-print for SBB andDBB, spaciouscable connectioninner cone

Single busbarsystemFixed typeFor tractionapplication1 or 2 polesolution

BIL 200 kV,suitablefor traction sidecontainerSubstationNo gas handling

Single busbarsystemFixed typeFor tractionapplication,1 or 2 polesolution

BIL 250 kV,suiteable fortraction sidecontainerSubstation

For railwayapplication 1 pole(170kV BIL)

For railwayapplication 1 or 2poles (250kV BIL)Single busbarsystemFixed typeFor tractionapplication, 1 or 2pole solution

BIL 250 kV,suiteable fortraction sidecontainerSubstation

Compact and modularswitchgearcombining all MV functional units

Compact and modularswitchgear combining all MV functional units

Compactand modularswitchgearcombining all MVfunctional units

Wind dedicatedmodular switchgearcombiningall MV functionalunits used in windfarms

Compact and modularswitchgear combiningall MV functional units

Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor andoutdoor

Indoor Indoor Indoor Indoor & Outdoor

Indoor

IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC IAC

DE

6048

8

PM

1028

33

24 24

12 1213.8

2 x 27.5

1 x 27.5

1 x 27.5

36 36

40.538

DM

1026

66

PE

5777

0

PE

9070

2

PE

9070

3

PE

9070

4

Panorama for MV distribution networks www.schneider-electric.com8

2SIS MV Fuses

Premset Fusarc CF Solefuse Tepefuse, Fusarc CF

MGK

IEC DIN/IEC IEC/UTE IEC/DIN/UTE AFNOR

Rated voltage (kV)

Max. rated current

630 A 250 A 5000 A (busbars)

400 A contactor

Max. rated short circuit current

25 kA 63 kA 50 kA 63 kA 50 kA

Vacuum CB

Compact modular switchgear with 3-in-1 architecture for breaking- disconnection and earthing

Fuses fordistributiontransformer protectionfrom 3.6 kV to 36 kV

Fuses for distribution transformer protection from 3.6 kV to 36 kV

Fuse for measurementtransformer protection up to24 kV (Tepefuse) and up to36 kV (Fusarc CF)Back-up technology

Motorprotectionfuse range

Indoor & Outdoor

IAC

36 36 36

12

15

PM

1005

99

PE

9070

6

Medium Voltage SwitchgearsShielded Solid Insulation System (2SIS)

Medium Voltage Fuses

Medium Voltage Instrument Transformers

7.2

Panorama for MV distribution networks 9

Medium Voltage SwitchgearsShielded Solid Insulation System (2SIS)

Medium Voltage Fuses

Medium Voltage Instrument Transformers

MV Instrument Transformers

IndoorCT / VT

Sensor Low VoltageRing Core

OutdoorCT / VT

IndoorCT / VT

CombinedOutdoor Unit

OutdoorVT

IEC IEC IEC IEC IEC/IEEE IEC/IEEE IEC/IEEE

Rated voltage (kV)

Max. rated current

2500 A 2500 A 5000 A 2500 A 3000 A 600 A 1500 A

Max. rated short circuit current

50 kA 40 kA 40 kA 50 kA 50 kA 50 kA 40 kA

Dry Dry Dry Dry Dry Dry Dry

Medium VoltageCurrentTransformer,VoltageTransformer

Ring type andMedium VoltageLow Power CurrentTransformer (LPCT)

Ring typeLow Voltage Transformer

Outdoor CurrentTransformer and VoltageTransformer

Ring or Bar typeCurrent Transformer andVoltageTransformer

Outdoorcombined CTsVTs measureunits for aerianand undergroundapplications

Outdoor CurrentTransformerand VoltageTransformer

36

72

36

40.540.5

0.72

24

PE

9029

6

PE

9030

2

PE

9030

3

PM

1030

13

PE

9029

7

PE

9052

9

PM

1030

14

PM

1030

05

Panorama for MV distribution networks www.schneider-electric.com10

Medium Voltage Disconnectors, Switches, Switch-Disconnections, ReclosersIndoor Switch-Disconnectors

Pole-Mounted Switchgears

Indoor Switch-Disconnectors Pole mounted switchgears

Railway

LBSkit L-TRI 5 TRI PM6 PM6 52 RL series N series U series W series SBC SDR CBR 22 CB NE TILF

IEC IEC IEC IEC IEC IEC/ANSI IEC/ANSI IEC/ANSI IEC/ANSI IEC IEC IEC IEC IEC/SNCB IEC/SNCB

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

630/1250 A 630/1600/2500 A 630 A 630 A 630 A 800 A 630 A 400 A 630 A 2000 A 2000 A 1000 A 2000 A 3150 A

Max. rated short circuit current Max. rated short circuit current

25 kA 20 kA 20 kA 16 kA 12.5 kA / 3 s 16 kA 16 kA 12.5 kA 6 kA 20 kA 25 kA/ 40 kA

8 kA/ 25 kA

25 kA 16 kA 25 kA 25 kA

SF6 AIR AIR SF6 SF6 Vacuum / SF6 Vacuum / SF6 Vacuum / Epoxy Vacuum / Epoxy Air Vacuum Vacuum Vacuum

Indoor load breakswitch, disconnector and accessories

Indoor loadbreak switchdisconnectorandaccessories

Indoordisconnectorandaccessories

Load break switch

Remote controlled with Easergy T200 P control unit

Manual or automatic load break switch

Sectionaliser capabilities

Load break switch

Remote controlled with ADVC controller

Manual orautomaticload break switch

Sectionalisercapabilitieson voltage and current

Recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Single Wire Earth Return (SWER)recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Air break switch and disconnector

Manualy operated

Fixed load breakswitch for AC railwayapplication

Fixed CircuitBreaker forAC railwayapplication

For locomotives and ElectricMultiple Units (EMU)

Outdoor on locomotive top

Single pole loadbreak switchesfor DC railwaynetworks

Single pole loadbreak switchesfor DC railwaynetworks

Outdoor Outdoor On board

3636363638 38

52

12

PE

9071

2

PE

9071

1

PE

9071

0

PE

9070

9

PE

9070

8

PE

9070

7

Panorama for MV distribution networks 11

Medium Voltage Disconnectors, Switches, Switch-Disconnections, ReclosersIndoor Switch-Disconnectors

Pole-Mounted Switchgears

Indoor Switch-Disconnectors Pole mounted switchgears

Railway

LBSkit L-TRI 5 TRI PM6 PM6 52 RL series N series U series W series SBC SDR CBR 22 CB NE TILF

IEC IEC IEC IEC IEC IEC/ANSI IEC/ANSI IEC/ANSI IEC/ANSI IEC IEC IEC IEC IEC/SNCB IEC/SNCB

Rated voltage (kV) Rated voltage (kV)

Max. rated current Max. rated current

630/1250 A 630/1600/2500 A 630 A 630 A 630 A 800 A 630 A 400 A 630 A 2000 A 2000 A 1000 A 2000 A 3150 A

Max. rated short circuit current Max. rated short circuit current

25 kA 20 kA 20 kA 16 kA 12.5 kA / 3 s 16 kA 16 kA 12.5 kA 6 kA 20 kA 25 kA/ 40 kA

8 kA/ 25 kA

25 kA 16 kA 25 kA 25 kA

SF6 AIR AIR SF6 SF6 Vacuum / SF6 Vacuum / SF6 Vacuum / Epoxy Vacuum / Epoxy Air Vacuum Vacuum Vacuum

Indoor load breakswitch, disconnector and accessories

Indoor loadbreak switchdisconnectorandaccessories

Indoordisconnectorandaccessories

Load break switch

Remote controlled with Easergy T200 P control unit

Manual or automatic load break switch

Sectionaliser capabilities

Load break switch

Remote controlled with ADVC controller

Manual orautomaticload break switch

Sectionalisercapabilitieson voltage and current

Recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Single Wire Earth Return (SWER)recloser

Remote controlled with ADVC controller

Advanced protection, control andcommunication

Air break switch and disconnector

Manualy operated

Fixed load breakswitch for AC railwayapplication

Fixed CircuitBreaker forAC railwayapplication

For locomotives and ElectricMultiple Units (EMU)

Outdoor on locomotive top

Single pole loadbreak switchesfor DC railwaynetworks

Single pole loadbreak switchesfor DC railwaynetworks

Outdoor Outdoor On board

3627

24

PM

1026

91

PE

9071

5

PE

9071

4

PE

9071

3

PM

1026

89

PE

9029

2

PE

9028

9

PE

9029

0

25 (1ph)

27.527.5

15

3.8 3.8

Panorama for MV distribution networks www.schneider-electric.com12

Control & Monitoring

MV components for switchgear control Feeder Automation Remote monitoring and control

Remote Control for MV Substations Remote Monitoring for MV Substations

MV/LV Substation power supply

Fault Passage Indicators for Underground Networks Telecontrol interface for pole-mounted load-break switch

Remote Monitoring for Overhead Networks

Fault Passage Indicators for Overhead Networks

GemStart 5.4 GemStart 5 GemView GemControl Easergy L500 EasergyT200I - T200E

Easergy R200-ATS100

EasergyFlair 200C

Easergy PS100 Easergy Flair 219, 279

Easergy Flair 510, 570, 590

Easergy Flair 21D, 22D, 23D, 23DM

Easergy T200P ADVC Easergy Flite 116-SA/G200

Easergy Flite ILIS

Ideal for IEC MV & LV motor starters with ratings from 0.5 kW to2 MW. Partnered with PIX MCC and also suitable for Motorpact/ OKKEN

Applications:Integrated MotorControl andProtection. Multiline LCD front panel, multi voltage inputsolution requiring no interposing relays.Exclusive MemoryModule (PAMM),Self Tuningprotection. Industryleader and standard in many Oil & Gasapplicationsworld-wide

Protocols:Modbus RTU,Profi bus DP V1using Generic MotorManagement profilefor plug and play solutions

Hand HeldProgrammerExclusive toGemStart5 Highestpossible security.Avoids the use oflaptopRequires a Key forprotection modification

Applications:Ensures fullcompliance with best practice and permit to work principles inOil & Gasapplications.Work at a convenientheight with userfriendly control and reset buttons.Only authorisedoperators mayconfi gure or reset trips

PLC and PC based solution for MV & LV Process control systems. Partneredwith GemStart 5,PIX MCC and LVSwitchgear

Applications:Intelligent MotorControl andMonitoring System(IMCS) to Chevron, Shell, BP, ExxonMobil, Conoco Philips and most other Oil & Gas standardsPredictivemaintenance,trending, alarms,plant visualisationin a semi standard/ custom package.Completes the Oil & Gas solution offer.

Protocols:Modbus RTU,Profi bus DP V1,Ethernet TCP I/PA library of otherprotocols is availableto integrate otherdevices andprotection relays

Smart SwitchgearManagementDigital control & monitoringsolution for air-insulated andgas-insulated switchgear fromsimple to complexapplications, due to its very scalable design

Applications:Switchgear central control unit, central monitoring and central information source, separated from protectionfunction.Advanced front panel for safeand intuitive guided operation.Base Unit with open SCADA-Communication for standard IEC-protocols andindustry protocols.Sofware based on robust standard PLC software.Direct process control possible

Protocols:IEC 60870-5-101Modbus-RTUProfibus-DPIEC 60870-5-103IEC 60870-5-104IEC 61850, Modbus TCP

Remote control system

Capacity500 Easergy type devicesNetwork and substation viewsAlarm logs, archives

Data configurationProfessional communicationsand database editorData creation via dialogueboxes

ProtocolsModbus, Modbus IP, IEC 101/104

CommunicationPermanent and non permanent:telephone/GSM, radio, direct public and dedicatedprivate linePeriodic call management

OptionWebview, Multistation andHorn/Lamp indication options

Switchmonitoring andcontrol unit

Fault indicator:phase and earth fault

Capacity1-16 switches

Batteryautonomy 16 h

Motorisation24 - 48 VDC

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS, 3G

Programmation IEC 61131-3

Modbus IEDsconcentrator

Switchmonitoring andcontrol unit

Control and monitoring through embedded devices in MV switchgear Premset, SM6 (end 2014)

Fault indicator: Flair 23DM

Control unit: SC110

Backup power supply: PS100

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS, 3G

Modbus IEDsconcentrator

DetectionPhase and earth fault

InstallationWall-mounted

Earthingsystem: direct,impedent,compensated, isolated

MeasurementU,I, P, Q, S, cosϕ6 D.I., 3 D.O.

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

Communication1 communication portTransmission interfaces:PSTN, radio, GSM, GPRS,Ethernet, RS232, RS485...

Modbus IEDsconcentrator

Power supply and battery charger for MV/LV substation.

24V or 48V for motor and IEDs supply12V for communication device supply

Autonomy up to 48h

90W for 24/48V permanent load300W 1mn for motor supply10kV insulation

Monitoring of battery to detect end of life through Modbus communication

Detectionphase and earth fault

Settingon site by dip switch

Installationwall mounted3 phases or / andearth CT

Earthing systemdirect, impedant

Detectionphase and earth fault

Settingon site by HMI throughpush buttons

Installationwall mounted3 phases or / andearth CT

Earthing systemdirect, impedant, compensated, isolated

Detectionphase and earth fault

Settingon site by dip switch or with keyboard

InstallationDIN formatintegrated into switchgear

Earthing system direct impedant, compensated, isolated

Measurementammeter,maximeter

Switch or sectionalisermonitoring and control unit

Fault indicator: phase and earth fault

MeasurementCurrent, voltage, real power,reactive power, power factor, demand, cosϕ

Capacity2 switches

Battery autonomy16h

Motorisation voltage24-48 VDC

ProtocolsModbus, Modbus/IP, IEC 870-5-101/104, DNP3,DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS 3G

Modbus IEDsconcentrator

ControlControls recloser

ProtectionPhase and earth current,directional, voltage, frequency,harmonics

DetectionPhase and earth faults, directional

MeasurementCurrent, voltage, real power,power factor, demand,harmonics, supply outages,waveform capture

SettingBy laptop, operator control panel, Scada

InstallationMounted on the pole or substation frame

ProtocolsDNP3, IEC 870-5-101/104Modbus/IP and DNP3/IP

CommunicationRadio, modem, GSM, V23,RS232, RS485, 10BaseT Ethernet

DetectionPhase-to-phase and phase-to-earth fault

Installationclip on or G200 pole mounted

ProtocolsIEC 870-5-101, SerialDNP3 and TCP/IP,Modbus

Communication915 MHz short range radio communication1 SCADA communicationportTransmission interface:radio, GSM, GPRS

Detectionphase and earth fault

Settingon site by dip switch

Installationclip on or polemounted

Earthing systemdirect, impedant,compensated,isolated

ILIS (Intelligent LightInformation System)Monitors light levelswithin SwitchgearcompartmentsApplications:Detects anddisconnects ARCfaults to limit damageto equipment. Diffuselight collection fromall directions, rapidtimed disconnectbetween 5 and250mS.Monitors up to 4compartments percolumn and up to 5columns on 4independant loops

Digital Digital PLC / PC /Software

Digital Scada Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital

Associated with all types of MV switchgear

T200E associated with Ringmaster only; limited to 4 switches.

Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration

Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration

ATS100: automatic source transfer with dedicated front panel.Lines, generator, bus tie

MV substation remotemonitoring unit

Battery220 VAC backed-up supply

Embedded web server.Local and remoteconfiguration

7 to 40 Ah lead long life batteryInput voltage:- 110 to 240 VAC- 110 VDC

Phase and earth fault indicator forunderground network

Power supply: - Flair 219: lithium battery - Flair 279: 220 VAC with backup lithium battery

1 output contact

Phase and earth fault indicator forunderground network

Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor

2 output contacts2 input contacts

Phase and earth fault indicator forunderground network. Self powered by CTs

Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor

2 output contacts2 input contacts

Associated with a pole mounted switch

Ensures remote controland automatedmanagement

Embedded web server.Local and remoteconfiguration

Advanced controller associated with N, U and W Seriesreclosers, and RL Series sectionaliser

Remote setting with WSOS monitoringand control software

Electronics sealed to IP65, 316 grade stainless steel enclosure

Control recloser Load Break Switch/Sectionnaliser type RL series

Communicating fault currentdetector for overheadlinesSingle-phaseammetric detector

Earth andphase-to-phase fault indicatorsfor overheaddistribution linesLithiumbattery power

PM

1028

20

PE

9029

5

PM

1028

22

PE

9034

3 V

3

DM

1030

98

PM

1023

01

DM

1030

99

PE

9071

6

PE

9071

7

PE

9071

8

Panorama for MV distribution networks 13

Control & Monitoring

MV components for switchgear control Feeder Automation Remote monitoring and control

Remote Control for MV Substations Remote Monitoring for MV Substations

MV/LV Substation power supply

Fault Passage Indicators for Underground Networks Telecontrol interface for pole-mounted load-break switch

Remote Monitoring for Overhead Networks

Fault Passage Indicators for Overhead Networks

GemStart 5.4 GemStart 5 GemView GemControl Easergy L500 EasergyT200I - T200E

Easergy R200-ATS100

EasergyFlair 200C

Easergy PS100 Easergy Flair 219, 279

Easergy Flair 510, 570, 590

Easergy Flair 21D, 22D, 23D, 23DM

Easergy T200P ADVC Easergy Flite 116-SA/G200

Easergy Flite ILIS

Ideal for IEC MV & LV motor starters with ratings from 0.5 kW to2 MW. Partnered with PIX MCC and also suitable for Motorpact/ OKKEN

Applications:Integrated MotorControl andProtection. Multiline LCD front panel, multi voltage inputsolution requiring no interposing relays.Exclusive MemoryModule (PAMM),Self Tuningprotection. Industryleader and standard in many Oil & Gasapplicationsworld-wide

Protocols:Modbus RTU,Profi bus DP V1using Generic MotorManagement profilefor plug and play solutions

Hand HeldProgrammerExclusive toGemStart5 Highestpossible security.Avoids the use oflaptopRequires a Key forprotection modification

Applications:Ensures fullcompliance with best practice and permit to work principles inOil & Gasapplications.Work at a convenientheight with userfriendly control and reset buttons.Only authorisedoperators mayconfi gure or reset trips

PLC and PC based solution for MV & LV Process control systems. Partneredwith GemStart 5,PIX MCC and LVSwitchgear

Applications:Intelligent MotorControl andMonitoring System(IMCS) to Chevron, Shell, BP, ExxonMobil, Conoco Philips and most other Oil & Gas standardsPredictivemaintenance,trending, alarms,plant visualisationin a semi standard/ custom package.Completes the Oil & Gas solution offer.

Protocols:Modbus RTU,Profi bus DP V1,Ethernet TCP I/PA library of otherprotocols is availableto integrate otherdevices andprotection relays

Smart SwitchgearManagementDigital control & monitoringsolution for air-insulated andgas-insulated switchgear fromsimple to complexapplications, due to its very scalable design

Applications:Switchgear central control unit, central monitoring and central information source, separated from protectionfunction.Advanced front panel for safeand intuitive guided operation.Base Unit with open SCADA-Communication for standard IEC-protocols andindustry protocols.Sofware based on robust standard PLC software.Direct process control possible

Protocols:IEC 60870-5-101Modbus-RTUProfibus-DPIEC 60870-5-103IEC 60870-5-104IEC 61850, Modbus TCP

Remote control system

Capacity500 Easergy type devicesNetwork and substation viewsAlarm logs, archives

Data configurationProfessional communicationsand database editorData creation via dialogueboxes

ProtocolsModbus, Modbus IP, IEC 101/104

CommunicationPermanent and non permanent:telephone/GSM, radio, direct public and dedicatedprivate linePeriodic call management

OptionWebview, Multistation andHorn/Lamp indication options

Switchmonitoring andcontrol unit

Fault indicator:phase and earth fault

Capacity1-16 switches

Batteryautonomy 16 h

Motorisation24 - 48 VDC

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS, 3G

Programmation IEC 61131-3

Modbus IEDsconcentrator

Switchmonitoring andcontrol unit

Control and monitoring through embedded devices in MV switchgear Premset, SM6 (end 2014)

Fault indicator: Flair 23DM

Control unit: SC110

Backup power supply: PS100

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS, 3G

Modbus IEDsconcentrator

DetectionPhase and earth fault

InstallationWall-mounted

Earthingsystem: direct,impedent,compensated, isolated

MeasurementU,I, P, Q, S, cosϕ6 D.I., 3 D.O.

ProtocolsModbus/IP,IEC 870-5-101/104,DNP3, DNP3/IP

Communication1 communication portTransmission interfaces:PSTN, radio, GSM, GPRS,Ethernet, RS232, RS485...

Modbus IEDsconcentrator

Power supply and battery charger for MV/LV substation.

24V or 48V for motor and IEDs supply12V for communication device supply

Autonomy up to 48h

90W for 24/48V permanent load300W 1mn for motor supply10kV insulation

Monitoring of battery to detect end of life through Modbus communication

Detectionphase and earth fault

Settingon site by dip switch

Installationwall mounted3 phases or / andearth CT

Earthing systemdirect, impedant

Detectionphase and earth fault

Settingon site by HMI throughpush buttons

Installationwall mounted3 phases or / andearth CT

Earthing systemdirect, impedant, compensated, isolated

Detectionphase and earth fault

Settingon site by dip switch or with keyboard

InstallationDIN formatintegrated into switchgear

Earthing system direct impedant, compensated, isolated

Measurementammeter,maximeter

Switch or sectionalisermonitoring and control unit

Fault indicator: phase and earth fault

MeasurementCurrent, voltage, real power,reactive power, power factor, demand, cosϕ

Capacity2 switches

Battery autonomy16h

Motorisation voltage24-48 VDC

ProtocolsModbus, Modbus/IP, IEC 870-5-101/104, DNP3,DNP3/IP

CommunicationRadio, PSTN, GSM, GPRS 3G

Modbus IEDsconcentrator

ControlControls recloser

ProtectionPhase and earth current,directional, voltage, frequency,harmonics

DetectionPhase and earth faults, directional

MeasurementCurrent, voltage, real power,power factor, demand,harmonics, supply outages,waveform capture

SettingBy laptop, operator control panel, Scada

InstallationMounted on the pole or substation frame

ProtocolsDNP3, IEC 870-5-101/104Modbus/IP and DNP3/IP

CommunicationRadio, modem, GSM, V23,RS232, RS485, 10BaseT Ethernet

DetectionPhase-to-phase and phase-to-earth fault

Installationclip on or G200 pole mounted

ProtocolsIEC 870-5-101, SerialDNP3 and TCP/IP,Modbus

Communication915 MHz short range radio communication1 SCADA communicationportTransmission interface:radio, GSM, GPRS

Detectionphase and earth fault

Settingon site by dip switch

Installationclip on or polemounted

Earthing systemdirect, impedant,compensated,isolated

ILIS (Intelligent LightInformation System)Monitors light levelswithin SwitchgearcompartmentsApplications:Detects anddisconnects ARCfaults to limit damageto equipment. Diffuselight collection fromall directions, rapidtimed disconnectbetween 5 and250mS.Monitors up to 4compartments percolumn and up to 5columns on 4independant loops

Digital Digital PLC / PC /Software

Digital Scada Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital

Associated with all types of MV switchgear

T200E associated with Ringmaster only; limited to 4 switches.

Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration

Ensure remote control and automatedmanagement.Embedded web server.Local and remoteconfiguration

ATS100: automatic source transfer with dedicated front panel.Lines, generator, bus tie

MV substation remotemonitoring unit

Battery220 VAC backed-up supply

Embedded web server.Local and remoteconfiguration

7 to 40 Ah lead long life batteryInput voltage:- 110 to 240 VAC- 110 VDC

Phase and earth fault indicator forunderground network

Power supply: - Flair 219: lithium battery - Flair 279: 220 VAC with backup lithium battery

1 output contact

Phase and earth fault indicator forunderground network

Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor

2 output contacts2 input contacts

Phase and earth fault indicator forunderground network. Self powered by CTs

Power supply :- Flair 510: Lithium battery- Flair 570: 110-220 VAC with backup Li battery- Flair 590: 110-220 VAC with backup super capacitor

2 output contacts2 input contacts

Associated with a pole mounted switch

Ensures remote controland automatedmanagement

Embedded web server.Local and remoteconfiguration

Advanced controller associated with N, U and W Seriesreclosers, and RL Series sectionaliser

Remote setting with WSOS monitoringand control software

Electronics sealed to IP65, 316 grade stainless steel enclosure

Control recloser Load Break Switch/Sectionnaliser type RL series

Communicating fault currentdetector for overheadlinesSingle-phaseammetric detector

Earth andphase-to-phase fault indicatorsfor overheaddistribution linesLithiumbattery power

PE

9071

9

PE

9072

0

PE

9072

1

PE

9072

2

PE

9072

3

PE

9072

4

PE

9072

5

PE

9072

6

Panorama for MV distribution networks www.schneider-electric.com14

Control & MonitoringProtection & control relays

PM

1027

03

PE

8803

0

PE

8802

2

PE

8802

3

PE

8802

4

PM

1005

02

PM

1005

22

PM

1005

27

Protection

Sepamseries 10

Sepamseries 20

Sepamseries 40

Sepamseries 60

Sepamseries 80

MiCOMseries 10

MiCOMseries 20

MiCOMseries 30

MiCOMseries 40

VAMP

Protection relay for basic applications

Protection relay for standard applications

Multi-functionprotection relay for demandingapplications

Multi-functionprotection relay forhigh-performanceapplications

Multi-functionprotection unit forcritical and customisedapplications

Protection relaysfor basic electricalschemes

Protection relays for standard electricalschemes

Multi-functionprotection relays forcomplex electricalschemes

Multi-functionprotection relays for complex electricalschemes

Dedicated ArcProtection Schemes

Secondary PowerDistribution Networks

Utility MV andIndustrial DistributionNetworks

Utility MV andIndustrial DistributionNetworks

Utility MV andIndustrial DistributionNetworks

Utility MV, Generationand Industrial DistributionNetworks

MV Industrial andBuilding Networks,Secondary andPrimary DistributionNetworks

Primary Distribution,MV Substations and Industrial Networks

Industrial Networks,Railways and Utility MV, HV Substations

Industrial Networks,Generation and UtilityMV, HV Substations

FeederTransformer

FeederBusbarTransformerMotor

FeederGeneratorTransformerMotor

FeederGeneratorTransformerMotorCapacitor

FeederBusbarTransformerMotorGeneratorCapacitor

FeederMotor

FeederMotorBusbarLine Differential

FeederMotorTransformerLine DifferentialDistanceRail

FeederMotorTransformerLine DifferentialDistanceBusbarGeneration

Arc ProtectionCommunication Protocol

Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital

Modbus RTUDNP3IEC 60870-5-103Modbus TCP/IP

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTU,IEC 60870-5-103

Modbus RTUDNP3IEC 60870-5-103Courier

Modbus RTUDNP3IEC 60870-5-101IEC 60870-5-103CourierIEC 61850

Modbus RTUDNP3IEC 60870-5-103CourierIEC 61850

Modbus RTUModbus TCPIEC 61850DNP3 TCPProfibusIEC 60870-5-101IEC 60870-5-103

Panel Panel Panel Panel Panel Wall/Surface,Panel or DIN Rail

Panel or Rack(with adaptor)

Panel, Wall/Surface or Rack

Panel or Rack Panel or DIN Rail

Panorama for MV distribution networks 15

Control & MonitoringProtection & control relays

PM

1005

26

PM

1035

32Protection

Sepamseries 10

Sepamseries 20

Sepamseries 40

Sepamseries 60

Sepamseries 80

MiCOMseries 10

MiCOMseries 20

MiCOMseries 30

MiCOMseries 40

VAMP

Protection relay for basic applications

Protection relay for standard applications

Multi-functionprotection relay for demandingapplications

Multi-functionprotection relay forhigh-performanceapplications

Multi-functionprotection unit forcritical and customisedapplications

Protection relaysfor basic electricalschemes

Protection relays for standard electricalschemes

Multi-functionprotection relays forcomplex electricalschemes

Multi-functionprotection relays for complex electricalschemes

Dedicated ArcProtection Schemes

Secondary PowerDistribution Networks

Utility MV andIndustrial DistributionNetworks

Utility MV andIndustrial DistributionNetworks

Utility MV andIndustrial DistributionNetworks

Utility MV, Generationand Industrial DistributionNetworks

MV Industrial andBuilding Networks,Secondary andPrimary DistributionNetworks

Primary Distribution,MV Substations and Industrial Networks

Industrial Networks,Railways and Utility MV, HV Substations

Industrial Networks,Generation and UtilityMV, HV Substations

FeederTransformer

FeederBusbarTransformerMotor

FeederGeneratorTransformerMotor

FeederGeneratorTransformerMotorCapacitor

FeederBusbarTransformerMotorGeneratorCapacitor

FeederMotor

FeederMotorBusbarLine Differential

FeederMotorTransformerLine DifferentialDistanceRail

FeederMotorTransformerLine DifferentialDistanceBusbarGeneration

Arc ProtectionCommunication Protocol

Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital

Modbus RTUDNP3IEC 60870-5-103Modbus TCP/IP

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTUModbus TCP/IPDNP3IEC 60870-5-103IEC 61850

Modbus RTU,IEC 60870-5-103

Modbus RTUDNP3IEC 60870-5-103Courier

Modbus RTUDNP3IEC 60870-5-101IEC 60870-5-103CourierIEC 61850

Modbus RTUDNP3IEC 60870-5-103CourierIEC 61850

Modbus RTUModbus TCPIEC 61850DNP3 TCPProfibusIEC 60870-5-101IEC 60870-5-103

Panel Panel Panel Panel Panel Wall/Surface,Panel or DIN Rail

Panel or Rack(with adaptor)

Panel, Wall/Surface or Rack

Panel or Rack Panel or DIN Rail

Panorama for MV distribution networks www.schneider-electric.com16

Oil Immersed Distribution Transformers

Oil Immersed Medium Power Transformers

Dry type Transformers Special Transformers

MINERA ODT Pole and ground mounted

MINERA MP TRIHAL SPT

Oil immersed type Dry type

Rated voltage (kV)

Power ratings

From 25 kVA up to 3.15 MVA > 3.15 up to 80 MVA From 100 kVA up to 15 MVA Up to 80 MVA Up to 30 MVA

Frequency

50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz 50 Hz - 60 Hz

Dielectric

Mineral Oil – IEC60296L ClassFire resistant oil (Vegeta)K Class (K2 - K3)

Mineral Oil – IEC60296L ClassFire resistant oil (Vegeta)K Class (K2 - K3)

Cast Resin encapsulated Certified C3* E3 F1

Custom solutions. Special applications - Compact Minera Siltrim- Minera EX (Zone 1 and 2)- Photovoltaic Minera PV- Compact Minera PAD- Full cast Tricast- Furnace transformer- Rectifier transformer- Generator transformers- Motor starting reactors- Others upon request- IP54, IP55 Dry Type Outdoor Transformers - Auto transformers- Single Phase Transformers- Self Protected Transformer- Dry Type Transformer with OLTC

Optimized efficiency

Standard lossesHigh Efficiency (Minera HE & HE+)

Standard lossesHigh Efficiency (Minera HE & HE+)

Standard lossesHigh Efficiency (Trihal HE)

Cooling system

ONAN – Natural airONAF – Air forced (up to 40%)

ONAN, ONAF, ODAF, ODWF or OFAF

AN - Natural airANAF / AF – Air forced (up to +40%)

Tank / Enclosure types

Hermetically sealedBreathing type

Hermetically sealed, gas cushion transformersFree-breathing with expansion tank

Common Design – Indoor useIP21, IP31, IP23Custom Enclosure – Outdoor useIP35, IP44

3652

36

PE

9073

2

Medium Voltage TransformersOil Immersed Distribution Transformers

Medium Power Transformers

Dry type Transformers

Special transformers

170 170

PE

9073

3

PE

9073

4

PE

9075

0

PE

9074

9

PE

9073

5

Panorama for MV distribution networks 17

Medium Voltage TransformersOil Immersed Distribution Transformers

Medium Power Transformers

Dry type Transformers

Special transformers

Power Factor Correction

Power Factor Correction

Propivar NG CP 200 series

IEC IEC

Rated voltage (kV)

Max. rated current

900 kVAR 14400 kVAR

Max. rated short circuit current

31.5 kA

"All film"with or withoutinternal fuses

Vacuum / SF6

Power factorcorrection onMV networksor devices

Power factorcorrection andharmonic filteringon MV networks

Fixed or automaticcapacitor banks for motor, substation,or globaldistribution

Indoor or outdoorinstallation

36 36

PB

1081

51

PE

9072

7

Panorama for MV distribution networks www.schneider-electric.com18

Medium Voltage / Low Voltage Prefabricated Substations (PSS)

Standard Substations - Integrated Standard Substations - Compact Standard Substations - Walk-in Customized substations

Specific substations (PSS) Prefabricated Substations Electrical House (E-House) Mobile substations Trackside substations

MV Switching kiosk MV/LV external operations MV/LV internal operations MV/LV Underground All voltage levels MV All voltage levels All voltage levels

IEC BS IEC / AS / HN IEC / AS / HN IEC / HN IEC IEC, HNBuilding codes: Eurocodes (according to specific type of substations)

IEC, AS, BS, ANSI/NEMA...

Building codes: Eurocodes, IBC, BCA

IEC, AS, BS, ANSI/NEMA...

Building codes: Eurocodes, IBC, BCA

Rated voltage (kV) Rated voltage (kV)

Transformer maximum power (kVA) Transformer maximum power (kVA)

Non applicable / without transformer

MV switchgearAutomationRTUUPS

MV switchgearMV MCCLV switchgearLV MCC, VSD,...AutomationUPSRTU,...

10MVA transformerHV/MV switchgearon & off-load tapchangers blackstart genset, UPSRTU & Sat ComCable reel

MV switchgearAutomationUPSRTU

Enclosure material Enclosure material

Without (frame mounted) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Truck mounted ■

Mode of operation Mode of operation

Indoor Indoor / Outdoor Outdoor Outdoor Indoor Indoor Indoor These substations offer modularity of their dimensions to respond to all equipmentrequirements

These substations offer modularity of their dimensions to respond to all equipmentrequirements

Complete stand-alone substation permanently mounted on a standard semi trailer to offer full mobility at highway speed without escort

These substations offer modularity of their dimensions to respond to all equipmentrequirements

Description Description

The MV and LV equipment are delivered directly mounted ensuring a safety, and fast solution. They can be installed in existing building, in a substation or outdoor*

*BS version

Outdoor operations type of substation allows reduce footprint and speed of installation. Internal equipment arrangement can be fitted to any type of access

Indoor operation provides to operator protection against bad weather and better working conditions. It offers fast delivery, safety and quick erection versus traditional construction. MV/LV Underground substations are invisible and fully integrated into the environment, allowing space saving whilst maintaining a high level of safety

These tailor made substations offer modularity of their dimensions to respond to all equipment requirements

Pre-fabricated primary substation complete withits ancillary equipment ready to be shipped,allowing minimal site work

Pre-fabricated substationcomprising primary supply and processcontrol switchgear,complete with ancillary equipment ready to be shipped, allowing minimal site work

Emergency power supply to back-up any HV/MVtransformer within a Utility network in less than 4 hours

Electrical supply ofcatenaries for main lines,high speed lines or freightlines

Application Application

DistributionBuidings

Distribution, industry, buidings

Distribution, buildings Distribution, industry, wind, buildings

Distribution, industry, wind, buildings

Distribution, buildings Primary and Secondary distributions, Large industries, Oil & Gas, Mine & Metal, Solar & Wind

Primary distribution,Large industriesOil & GasMining & MetalsSolar & Wind

Oil & Gas - Upstream, midstream, downstreamUtilities - HV/MV substationsMining & MetalsEnergy - Intensive industriesUtilities - Primary or reflection substationsRailways - Trackside substations

Primary distribution RailwaysMining & Metals

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Protection and reconfiguration of the MV undergrounded network.Equipped with MV Ring Main Units switchgears. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent)*. Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

*Non applicable to underground substations

■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete ■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete

36

2000

36

PE

9073

7

PE

9073

817.5

2000

630

36

PE

9073

9

PE

9074

0

1250

36 36

PM

1023

82

1 x1000 2 x

630

PE

9074

1

Panorama for MV distribution networks 19

Medium Voltage / Low Voltage Prefabricated Substations (PSS)

Standard Substations - Integrated Standard Substations - Compact Standard Substations - Walk-in Customized substations

Specific substations (PSS) Prefabricated Substations Electrical House (E-House) Mobile substations Trackside substations

MV Switching kiosk MV/LV external operations MV/LV internal operations MV/LV Underground All voltage levels MV All voltage levels All voltage levels

IEC BS IEC / AS / HN IEC / AS / HN IEC / HN IEC IEC, HNBuilding codes: Eurocodes (according to specific type of substations)

IEC, AS, BS, ANSI/NEMA...

Building codes: Eurocodes, IBC, BCA

IEC, AS, BS, ANSI/NEMA...

Building codes: Eurocodes, IBC, BCA

Rated voltage (kV) Rated voltage (kV)

Transformer maximum power (kVA) Transformer maximum power (kVA)

Non applicable / without transformer

MV switchgearAutomationRTUUPS

MV switchgearMV MCCLV switchgearLV MCC, VSD,...AutomationUPSRTU,...

10MVA transformerHV/MV switchgearon & off-load tapchangers blackstart genset, UPSRTU & Sat ComCable reel

MV switchgearAutomationUPSRTU

Enclosure material Enclosure material

Without (frame mounted) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Truck mounted ■

Mode of operation Mode of operation

Indoor Indoor / Outdoor Outdoor Outdoor Indoor Indoor Indoor These substations offer modularity of their dimensions to respond to all equipmentrequirements

These substations offer modularity of their dimensions to respond to all equipmentrequirements

Complete stand-alone substation permanently mounted on a standard semi trailer to offer full mobility at highway speed without escort

These substations offer modularity of their dimensions to respond to all equipmentrequirements

Description Description

The MV and LV equipment are delivered directly mounted ensuring a safety, and fast solution. They can be installed in existing building, in a substation or outdoor*

*BS version

Outdoor operations type of substation allows reduce footprint and speed of installation. Internal equipment arrangement can be fitted to any type of access

Indoor operation provides to operator protection against bad weather and better working conditions. It offers fast delivery, safety and quick erection versus traditional construction. MV/LV Underground substations are invisible and fully integrated into the environment, allowing space saving whilst maintaining a high level of safety

These tailor made substations offer modularity of their dimensions to respond to all equipment requirements

Pre-fabricated primary substation complete withits ancillary equipment ready to be shipped,allowing minimal site work

Pre-fabricated substationcomprising primary supply and processcontrol switchgear,complete with ancillary equipment ready to be shipped, allowing minimal site work

Emergency power supply to back-up any HV/MVtransformer within a Utility network in less than 4 hours

Electrical supply ofcatenaries for main lines,high speed lines or freightlines

Application Application

DistributionBuidings

Distribution, industry, buidings

Distribution, buildings Distribution, industry, wind, buildings

Distribution, industry, wind, buildings

Distribution, buildings Primary and Secondary distributions, Large industries, Oil & Gas, Mine & Metal, Solar & Wind

Primary distribution,Large industriesOil & GasMining & MetalsSolar & Wind

Oil & Gas - Upstream, midstream, downstreamUtilities - HV/MV substationsMining & MetalsEnergy - Intensive industriesUtilities - Primary or reflection substationsRailways - Trackside substations

Primary distribution RailwaysMining & Metals

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Protection and reconfiguration of the MV undergrounded network.Equipped with MV Ring Main Units switchgears. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent). Distributing and protecting the LV network with Opus and Prisma Plus ranges. Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear ranges. Supplying LV energy with oil transformer (Minera ranges or equivalent) and with cast resin dry type transformer (Trihal ranges or equivalent)*. Distributing and protecting the LV network with Opus and Prisma Plus ranges.Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200

*Non applicable to underground substations

■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete ■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete

PM

1028

35

PE

9031

3

PE

9032

5

PE

9073

6

PE

9031

7

40.5

15

3150

36 27.5

up to 72

up to 72

2 x27.5

Panorama for MV distribution networks www.schneider-electric.com2020 Panorama for MV distribution networks www.schneider-electric.com

Electrical Distribution Services

Comprehensive Electrical Installation Services from Schneider Electric

Your ElectricalDistribution Equipment

Greater Productivity,Reliability, andSafety

Electrical Distribution Services

Panorama for MV distribution networks 21Panorama for MV distribution networks 21

Electrical Distribution Services

Comprehensive Installed Base Services

Renew

PlanO

ptim

ize

Operate

Install

How do I renew mysolution?

What aremy options?

How do Iinstall andcommission?

How do Ioptimize?

How do Ioperate andmaintain?

AssetManagement

Life Cycle

Renew- ECOFIT™ - Modernization solutions - Infrastructure enhancement Plan

- Technical Feasability studies - Architecture & Design studies- Facility assessment

Install- Project management - Site coordination - Assembly & Start-up commissioningOperate

- Warranty Extensions/ Service Plans- Expert Technical support- Preventive / Predictive Maintenance- Spare Parts management- Technical Training

Optimize- Remote Monitoring

Services - Maintenance consulting - On-Site energy,

reliability- Safety assessment

Peace of mind for every stage of the lifecycle

Schneider Electric Korea Ltd. 슈나이더 일렉트릭 코리아(주)

NRJE

D11

1210

EN ⓒ

2014

Sch

neid

er Ele

ctric

. All

Rig

hts

Rese

rved. All

trad

em

arks

are

ow

ned b

y Sch

neid

er Ele

ctric

Indus

trie

s SAS o

r its

alia

ted c

om

pan

ies.

서울본사 부산지사 대구지사 대전지사 천안지사

서울 마포구 성암로 189 부산시 사상구 대구 북구 산격2동 대전 유성구 관평동 충남 천안시 서북구

중소기업 DMC타워 괘법동 559-13 1666 전기조명관 1342 디티비안 불당동 724

동훈빌딩 5층 크리스탈빌딩 401호 오피스텔 A동 836호 C&J빌딩 903호

Tel. 02 2630 9700 Tel. 051 319 7901 Tel. 053 604 6028 Tel. 042 822 3240 Tel. 041 552 0501

Fax 02 2630 9800~1 Fax 051 319 7900 Fax 053 604 6029 Fax 042 822 3241 Fax 041 552 0599

03/2014

This is only a summary of the product features and is for reference purpose only. The information herein is provided to you "AS IS" AND WITHOUT WARRANTY OF ANY KIND,

EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR

NON-INFRINGEMENT. While the information provided is believed to be accurate, it may include errors or inaccuracies; we assume no liability for errors or omissions in the content

of the information nor do we accept any liability as a result of reliance upon the information contained herein. In no event shall we be liable to any person for any special, indirect or

consequential damages relating to this material, unless caused by gross negligence or intentional misconduct.

모바일웹 페이스북

고객센터 : 1588-2630

웹사이트 : www.schneider-electric.co.kr

카 페 : www.energyforum.co.kr

트 위 터 : twitter.com/SchneiderKorea

블 로 그 : www.sch-log.com

페이스북 : www.facebook.com/SchneiderElectric

www.MyEnergyUniversity.co.kr 사이트에 키코드 43633y를 등록하시면 에너지 효율

향상 교육을 무료로 수강하실 수 있습니다. 지금 방문하시고 에너지 효율 챔피언이 되십시오!