Presented by Tyler Stewart [email protected]/fileadmin/images/bifi/denver/... ·...

21
bifiPV Workshop – September 10 th , 2018 : Denver, Colorado Bifacial Commercial Installations with Improved Bifacial Gains Presented by Tyler Stewart [email protected]

Transcript of Presented by Tyler Stewart [email protected]/fileadmin/images/bifi/denver/... ·...

Page 1: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCommercialInstallationswithImprovedBifacialGains

[email protected]

Page 2: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

Outline

• WhoisPrismSolarTechnologies?• Quickoptimizationmethod• Whatistheissuefacingtheoptimizationofbifacialsystems?

•  BifacialCommercialWhiteRoofs•  BifacialCarportSystems•  Conclusions

Page 3: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

PrismSolarTechnologiesInc.

•  PrismSolarTechnologieswasfoundedin2005.•  Researchingbifacialandholographic/bifacialtechnologyandapplicationssince2006(Hitachicells);sixawardedpatentsinbifacialtechnologyandapplications.

•  Commerciallysellingbifacialmodulessince2012.

Page 4: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

DesignOptimizationWithModelBGE’(%) = (0.317/deg*(θ)+12.145/m*(h)+0.1414/%*(α)) * (BR’[%]/95%) *(Azimuth Correction Factor(%)) * (Inter-row Correction Factor(%)) * (1-η(%))

θ = Module Tilt Angle (deg) h = Module Minimum Height/Elevation (m) α = Ground Albedo/Reflectance BR’ = Bifacial Ratio, or Bifaciality of the Module η  = Rear Obstruction Factor (%)

Total Bifacial System Energy Yield [%] = Monofacial*(BGE’(%) + 100%)

Azimuth Correction Factor =0.0000822*(φ^2)-0.0005129*(φ)+0.9988

φ=Azimuthdeviationfromsouthinnorthernlatitude(deg.) Inter-row Correction Factor =(-0.0467*(t)+1.42)*100%;max=100%,min=86%

t=TimeusedforDec21stShadowLengthCalculationsforinter-rowspacingdetermination;between9amand12pm.PrismSolarModelReference:J.E.Castillo-AguilellaandP.S.Hauser,"Bifacialphotovoltaic module best-fit annual energy yield model with azimuthalcorrection," 2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC),Portland,OR,2016,pp.3109-3112.doi:10.1109/PVSC.2016.7750238

AgoodmatchhasbeenfoundbetweenthePrismSolarannualbest-fitmodelandtheannualresultswith PVSyst 6.70 for the high bifacial gainsregionsofinterestofthispresentation.

**Use your preferred model toestimate bifacial gains for yourdesign**

Page 5: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

OptimizingtheBifacialGain:Issue

MaximizingthebifacialgainbeyondcertainvaluescansignificantlyincreasethecostofthebifacialsystemBifacialgainsreachsaturationpointsatcertainheightsandtilts.Thisisespeciallytrueinareaconstrainedinstallationsites.

Maximumbifacialgainsleadtocostincreasesthatarenotcompensatedbythepeakachievablebifacialgain.Lawofdiminishingreturns

Page 6: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

ExamplesofBifacialInstallationsinLiterature

TableSource:Sun,Xingshu,Khan,MohammadRyyan,Deline,Chris,andAlam,MuhammadAshraful.Optimizationandperformanceofbifacialsolarmodules:Aglobalperspective.UnitedStates:N.p.,2018.Web.doi:10.1016/j.apenergy.2017.12.041.

Page 7: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCommercialWhiteRoofCommercialRooftopAndBifacialModules:•  Higheralbedo•  Highertiltacceptable•  Increasedmoduleheight(advantageinsnowyregions)•  Optimizers/Microinverter[*](Otherbuildingcodebenefits)DetrimentalSystemConsequences:•  Areaconstrained,lowersystemGCRduetohighertilt•  Lackofwinddeflector&atthehighermoduletiltand

heights,rackingcostscanbecomeprohibitive.•  Optimizingthebifacialgainleadstolessmodulesinstalled

[*]: Riley, D. et al. 2018 Performance of Bifacial PV Modules with MLPE vs. String Inverters, WCPEC-7, Waikoloa, HI.

Page 8: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialOptimizedRackingExamples

Additionalbracingforextraheightandsnowloads

Uprightrackingelementscanbereducedinquantity,reducingthesystemcosts,increasingtheRearObstructionFactorforthebifacialmodule.Alternative,thecross-railscanbestrengthenedtoreducethenumberofuprights,butthisalsoincreasesthesystemcost. Rearobstructionfactorsof4%

to5%arerelativelyeasytoobtainwithcarefuluprightplacement,buttryingtoachieve0%to2.5%mightbecostprohibitivefromarackingperspective.

Page 9: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

WhiteRoofsBifacialRecommendations•  Min.TiltAngle=10degrees;Max.TiltAngle=30degrees•  Min.ModuleElevation=0.3m;Max.ModuleElevation=0.5m,

or0.6mforsnowregions•  Min.InitialRoofAlbedo=75%(Albedodecreaseswithtime)•  Min.Inter-rowspacing=11am•  Min.recommendedrearObstructionFactor=3%•  Max.recommendedrearObstructionFactor=8%

Usingallthesevaluesattheworstcondition,andusingthePrismSolarbifacialmodel,thisstillyieldsa~14%BifacialGainwitha90%Bifacialitymodule.

Thebifacialgainwouldbedirectlyreducedifthemodulebifacialityisreduced.

Page 10: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

154.3kWBifacialUpstateNYInstallation

Page 11: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

Component Model Rating(W) QTY Specifications/Manufacturer’sWebsite:Module Bi60-368BSTC 290WDC 532 http://www.prismsolar.com/pdf/bi60specs.pdfOptimizer P730 730WDC 266 http://www.solaredge.com/sites/default/files/se-P5-series-

commercial-add-on-power-optimizer-datasheet-na.pdfInverter SE33.3KUS 33,300WAC 5 http://www.solaredge.com/sites/default/files/se-three-phase-us-

inverter-datasheet.pdfRacking SunrailBifacial - - http://opsun.com/mounting-solutions/flat-roof/bifacial-pv-

racking/

020406080100120140160180200220240260280300320

0

25000

50000

75000

100000

125000

150000

175000

3/22/20176:00

3/22/201710:48

3/22/201715:36

3/22/201720:24

3/23/20171:12

3/23/20176:00

3/23/201710:48

3/23/201715:36

3/23/201720:24

AVGM

oduleAC

produ

ction(W

)

System

Produ

ction(W

)

SystemandAverageModuleProduction(InverterLimited)

15minSystemProduction(W)

15minAVGSystemProduction/module(W)

Clientsupplieddatasystem:Basedonthemodulesandinverters,thesystemhasaDC/ACratioof0.927Inter-rowspacing11am,Albedoof+75%,systemtiltof30degrees,Azimuth=10degreesfromsouth,andRearObstructionFactorof~5%.Oncetheoptimizerscapped,themoduleswereproducing12.7%to21.45%overSTC.UsingthePrismSolarModel+PVSystforthefrontyieldsayearlyoutputof1633.5kWhac/kWdc.ThePVSystbifacialmodelV6.70yields1657kWhac/kWdc.

154.3kWBifacialUpstateNYInstallation

Page 12: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

154.3kWBifacialUpstateNYInstallation

Clippingwas

Observed

Page 13: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

Themedianannualproduction,usinga12-monthaveragingwindowis1633.9kWhac/kWdc.MedianPR=1.025

154.3kWBifacialUpstateNYInstallationThesystemwasturnedonafewmonthsbeforetheirradiancesystem/PRsystemwasputinplace.ThehighestPerformanceRatio(PR)coincideswithlowestdailykWh/kW,andvice-versa.

98.4478.50

57.64

117.02

152.33 149.73 159.11179.85 179.96 175.48 166.53

135.70

94.5566.56

96.7284.98

138.55 144.61169.90 174.41 175.97

0

60

120

180

N-16 D-16 J-17 F-17 M-17 A-17 M-17 J-17 J-17 A-17 S-17 O-17 N-17 D-17 J-18 F-18 M-18 A-18 M-18 J-18 J-18

Mon

thlyACEn

ergy

Gen

erated

[kWh/kW

] MonthlyEnergyProduction[kWh/kW]

0.6

0.8

1

1.2

1.4

1.6

0

1

2

3

4

5

6

7

8

9

10

2/22/173/8/173/22/174/5/174/19/175/3/175/17/175/31/176/14/176/28/177/12/177/26/178/9/178/23/179/6/179/20/1710/4/1710/18/1711/1/1711/15/1711/29/1712/13/1712/27/171/10/181/24/182/7/182/21/183/7/183/21/184/4/184/18/185/2/185/16/185/30/186/13/186/27/187/11/187/25/18

Performan

ceRatio(P

R)

DailyEne

rgyProd

uctio

n[kWh/kW

]

DailyEnergyProductionforthe154.3kWBifacialSystem(532Modules)DailySystemProduction(kWh/kW)PerformanceRatio(Bi60-290W)14per.Mov.Avg.(PerformanceRatio(Bi60-290W))

Page 14: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

CommercialRooftop•  Bifacialrooftopandcarport

systeminQuebec,Canada.•  30Degreemoduletilt•  Elevation=0.42m•  EstimatedBifacialGain=+20%•  OwnerdatasinceJuly2018

Page 15: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCarportsCarportAndBifacialModules:•  Highercarportmodule/systemheight•  East/WestConfigurations•  UsuallynotGCRconstrained•  Aligningthemoduleslongedgeswiththestructurepurlins,reducesthe

RearObstructionFactor.

DetrimentalSystemConsequences:•  Rackingcostsincreasewithcarportheightandtiltanglesover+10degrees•  GroundReflectance/Albedoinmostcasesbetween8%(FreshAsphalt)

-20%,rarelyexceeds40%.•  Increasingtheheightortiltangleexcessively,canreducethecarport

shadingeffectforthevehiclesunderthestructure.

Page 16: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCarportsRecommendations

•  Min.TiltAngle=7degrees;Max.TiltAngle=20degrees•  Min.ModuleElevationRatio=0.3•  Max.ModuleElevationRatio=0.6•  Max.recommendedrearObstructionFactor=10%

Usingallthesevaluesattheminimum/worstcondition,Albedo=10%,andusingthePrismSolarbifacialmodel,thisstillyieldsan~6%BifacialGainwitha90%Bifacialitymodule.Thisincreasesto~10%foranEast/Westinstallation.

Thebifacialgainwouldbedirectlyreducedifthemodulebifacialityisreduced.

Page 17: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCarportExample

Carportsystemdesignedinsuchamannertominimizetherearobstructionfactor,modulealignedwithpurlins,andthemajorstructureelementsareplacedintheplaceswheremodulesmeet.

Page 18: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

BifacialCarportExample

• ElevationRatio=~0.5• +600kWBifacialcarportsysteminQuebec,Canada.

• MostlyE/Waligned• DatasinceJuly2018

Page 19: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

9.72kW(36modules)DC/ACratio=1.28(capsMay-Aug)BifacialRatio=90%Azimuth=EastFacingHeightRatio=0.5Tilt=7degreesAlbedo/SR=40%EstimatedBifacialGain:21.4%Ownerprovideddata

BifacialCarport–TucsonAZ(2Yeardata)

Theaveragemeasuredannualenergyproductionforthe2yearperiodwas1817.9kWhac/kWdc

TheaveragedGainmeasuredforthe2yearperiodwas19.6%,justunderthepredicted21.4%.

Page 20: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

Conclusions•  Significantbifacialgain’sareobtainableinvariousrealworldapplications

•  MaximizingBGEgenerallydoesnotmakefinancialsense

•  Financialoptimizationisthekey•  Allthesitevariablesmustbeconsideredwhendesigningthesystem.Thisincludescostofelectricity

Page 21: Presented by Tyler Stewart t.stewart@prismsolarnpv-workshop.com/fileadmin/images/bifi/denver/... · 2018-09-21 · bifiPV Workshop – September 10th, 2018 : Denver, Colorado Bifacial

bifiPVWorkshop–September10th,2018:Denver,Colorado

ThankYou