Energy Efficient Steam Systems

description

Energy efficient steam systems

Transcript of PRESENTATION Energy Efficient Steam Systems'

Energy Efficient Steam SystemsSteam SystemsSteam systems most widely used type of process heatingAdvantages of steam:Heat carrying capacity of steam much greater than air or waterSteam provides its own locomotive forceSteam provides heat at a constant temperaturelb/hr to deliver 1 mmBtu/hr of heatSteam SystemSteam SystemEnergy FlowsEnergy enters a steam system as:Fuel and combustion airMakeup waterPump workEnergy leaves a steam system as:Heat to the processEhaust air!lowdown"ondensate lossFlash vaporHeat loss from the boiler# steam pipes# condensate pipes and deaerator tank$Fuel %se &educedFuel use reduced by reducing:Heat to the processHeat in ehaust air!lowdown"ondensate lossFlash vaporHeat loss from the boiler# steam pipes# condensate pipes and deaerator tank$Energy Saving 'pportunities() &educe Steam *emand+nsulate hot surfaces"over uninsulated tanks,) Fi Steam -rapsSteam traps are automatic valves that discharge condensate from a steam line without discharging steam$ +f the trap fails open# steam escapes into the condensate return pipe without being utili.ed in the process$ +f trap fails closed# condensate fills the heat echanger and chokes/off heat to process$Fiing failed steam traps is highly cost/effective$ 0) +nsulate Pipes and -anks+nsulatesteam pipescondensate return pipescondensate return tanksdeaerator tankvalves1) Preheat !oiler Feed/water %sing Ehaust AirEconomi.er is heat echanger that preheats feed/water to the boiler using heat from the ehaust gasses$Economi.ers are most cost effective in process boilers that operate all year$ 2) Minimi.e Steam Pressure3enerating steam at ecess pressure:decreases boiler efficiencyincreases heat lossincreases flash loss$&educing boiler pressure to match the highest re4uired process temperature decreases these losses$ &educing steam pressure to match local re4uired process temperature reduces flash loss$ -hus# always produce and supply steam at the minimum pressure re4uired to meet the process temperature re4uirement$ 5) +nstall Automatic !low *own "ontrols!low down is the practice of epelling steam to reduce contaminant build ups$ -ypical blowdown rates range from 16 to 76 of boiler feed/water$ Manual blowdown relies on intuition or periodic testing$Always results in ecess blow down that wastes energy or insufficient blow down that creates ecess scale on heat transfer surfaces and reduces efficiency$Automatic blow down reduces energy# water and water treatment costs$%nderstanding "ombustionStoichiometric Combustion Air: No Safety MarginCH4 + 2 (O2 + 3. N2!

CO2 + 2 H2O + ".# N2$%& '(cess Combustion Air:Correct Safety MarginCH4 + 2.2 (O2 + 3. N2! CO2 + 2 H2O + .4 N2 + %.4 O2$%%& '(cess Combustion Air: )oo Much AirCH4 + 4 (O2 + 3. N2! CO2 + 2 H2O + $*.2 N2 + 2 O2%nderstanding "ombustion Efficiency Efficiency highest at 8'9 E:"ESS A+& and 8'9 S-A"; -EMPE&-%&ESS-A"; -EMPE&A-%&E increases with F+&+