Transcript of Ppt on rs logix 5000
By:-ANIL MAURYA
ELECTRICAL & ELECTRONICS
ENGINEER
1
� A Programmable controller is a solid state user programmable control system with functions to control logic, sequencing, timing, arithmetic data manipulation and counting capabilities. control logic, sequencing, timing, arithmetic data manipulation and counting capabilities.
� Programming changes are easy to enter by maintenance personal and plant engineer.
� Programmable control systems can survive harsh, industrial environments.
2ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
Why Choose RSLogix 5000?
� Innovations� No need to point to physical memory addresses when writing code.
Use names to represent data variables. � Use names to represent data variables.
RSLogix 5000 : No access to memory addresses
RSLogix 500 : Can access memory directly
Low-level language
3ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
Advantages:
Used to program all Automation Logix platforms: � ControlLogix� ControlLogix� CompactLogix� FlexLogix� DriveLogix.
4ANIL MAURYA ELECTRICAL &
ELECTRONICS ENGINEER
�� Devicenet variable speed drivesDevicenet variable speed drives
�� Ethernet wireless controlEthernet wireless control
�� PanelView control / monitoring of equipmentPanelView control / monitoring of equipment
5ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
6ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
7ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
� Compact I/O has a unique modular rackless design, which both contributes to system cost savings and reduces parts inventory
� Its communication bus, typically found in � Its communication bus, typically found in the I/O rack, is instead integrated into each Compact I/O module
8ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
9ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
� Simple and affordable processors with broad capabilities to address applications such as material handling, HVAC control, assembly operations, small process control, and SCADA applications.
� Advanced instruction-set based on PLC-5 mid-size processors.
� Each SLC 5/01 processor has a DH-485 port for � Each SLC 5/01 processor has a DH-485 port for programming and processor-to-processor communication initiated from the other node.
� SLC 5/02, SLC 5/03, SLC 5/04 and SLC 5/05 processors have communication ports that can initiate communication (e.g., Ethernet, DH+, DH-485, or RS-232-C).
10ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
Customize Processors
� ControlNet
DeviceNet � DeviceNet
� Universal Remote I/O
� BASIC programming capability
11ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
12ANIL MAURYA
ELECTRICAL & ELECTRONICS ENGINEER
13
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
14
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
15
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
16
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
17
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
18
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
19
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
20
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
21
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� Modify while running
� Fine-tune an operating control systemincluding PID loops
� Reduces development time
� Troubleshooting
22
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
23
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
24
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� DF1 protocol is a data-link layer protocol that combines features of subcategories D1 and F1 of ANSI x3.28 specification.
Half-duplex protocol (master-slave communication)� Half-duplex protocol (master-slave communication)
� Full-duplex protocol (peer-to-peer communication)
� Formal Driver Type: Serial, Client or Server
� Connection type: RS-232 or RS-48525
ANIL MAURYA ELECTRICAL & ELECTRONICS ENGINEER
26
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
PLC Replacement Programming Cable for the RSlogix PLC Replacement Programming Cable for the RSlogix Series Series
�� Allen Bradley:Allen Bradley: 17611761--CBLCBL--PM02PM02
CableCable
�� Supports RSLinx communications (DF1 or DHSupports RSLinx communications (DF1 or DH--485) 485) between SLC 5000, controllogix, and 1761 devices: between SLC 5000, controllogix, and 1761 devices:
�� For example:For example:
��NET DNINET DNI
��NET AICNET AIC
��NET ENI NET ENI 27
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
28
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� Mixing Media on a DeviceNet trunk line
� Thick, Thin, and Flat (KwikLink) are 120 ohm impedance cables
� Apply the 'weakest link' theory when calculating distances allowed.
� when mixing cables, use KwikLink specs. To determine � when mixing cables, use KwikLink specs. To determine maximum length allowed
� Return (V-) and shield should be grounded in accordance with DNet requirements; (reference DN-6.7.2) available on Rockwell website
� Proper grounding discussed in Knowledgebase record G21030.
29
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
EthernetEthernet 1761 NET ENI1761 NET ENI ControlLogixControlLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
ControlLogixControlLogix 1761 NET DNI1761 NET DNI CompactLogixCompactLogix⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
CompactLogixCompactLogix 1761 NET AIC 1761 NET AIC PLC 5000PLC 5000⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
30
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
InternetInternet DeviceNET BusDeviceNET Bus DH1 or DH485 KitDH1 or DH485 Kit⇒⇒⇒⇒⇒⇒⇒⇒ ⇒⇒⇒⇒⇒⇒⇒⇒
Using:• RSLinx• 1761 Interface Devices• PM02 Cable(s)
31
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
32
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
Data Sheet Of Cables
33
34
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� 1784-PCC driver enhanced to increase browsing performance. The node table object on the card now determines valid nodes instead of RSLinx browsing for them.
� Support added for a new item property (I.D. is 5000). This property exists only for ControlLogix items and will test an item to determine if it is boolean.
35
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� New DeviceNet error code added for better address parsing of parameter errors.
Specific support includes:
� Date and Currency� Date and Currency
� Returning errors when values out of range
� Failing the AddItems when requested data type is invalid
36
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
37
38
� Online programming
� Offline programming
� Test and troubleshooting
39
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
40
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
41
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� Network through any standard RJ45 Ethernet cable
� 100 Base-T Port with embedded LEDs allows � 100 Base-T Port with embedded LEDs allows connection to provide easy-to-see link transmit / receive
42
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
� Using the 1761 series adapters designed for the RSlogix platform to connect the controllogix, Compactlogix and PLC 5000 controllers allows the ultimate in flexibility between components and industry standard Ethernet and Devicenet and industry standard Ethernet and Devicenet components.
43
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER
44
ANIL MAURYA ELECTRICAL & ELECTRONICS
ENGINEER