Power point presentation tech 3 - Penn State … · Schematic Lighting Proposal ... Center for the...
Transcript of Power point presentation tech 3 - Penn State … · Schematic Lighting Proposal ... Center for the...
Center Center for thefor the ArtsArtsTowson, MarylandTowson, Maryland
Schematic Lighting ProposalSchematic Lighting Proposal
Ben MittenBen Mitten
Architectural EngineeringArchitectural EngineeringPennsylvania State University Pennsylvania State University
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsLocationLocation
Towson UniversityCenter for the Arts
7815 Osler DriveTowson, MD 21252
Towson University Map
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsProject DataProject Data
General InformationGeneral Information
Overall size of the project Overall size of the project –– 288, 000288, 000 square feetsquare feet
Total project budget Total project budget -- $ $ 4242 millionmillion
Occupants:Occupants:Dance ProgramDance Program
Art ProgramArt Program
Music ProgramMusic Program
Theater ProgramTheater Program
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsBuilding LayoutBuilding Layout
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Large Work SpaceLarge Work SpacePaint StudioPaint Studio
Special Purpose SpaceSpecial Purpose SpaceDance StudioDance Studio
Circulation SpaceCirculation SpaceMain LobbyMain Lobby
Outdoor SpaceOutdoor SpaceNorth FaNorth Faççadeade
Conceptual Design SpacesConceptual Design Spaces
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsBuilding LayoutBuilding Layout
Paint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
LocationLocation44thth floor of the northfloor of the north--east section of the east section of the buildingbuilding
Space CharacteristicsSpace CharacteristicsSize- 1668 square feetMajor space properties- Projection screen surface mounted- Entire north wall is glazing- Floor easels - Exposed ceiling with height of 14’ – 6”
TasksTasksPainting- Figures, Human Models, objectsPresentations/Pin-upsSketching
Paint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design CriteriaDesign CriteriaProvide light for correct color appearance and contrastProvide light for correct color appearance and contrast
Lighting for facial modeling and objectsLighting for facial modeling and objects
Distribution of light on easelsDistribution of light on easels
Manual lighting system and daylight controls Manual lighting system and daylight controls
Illuminance of 50 fc on the horizontal and 30 fc on the verticalIlluminance of 50 fc on the horizontal and 30 fc on the vertical
FlinnFlinn Mode to achieveMode to achieve-- clearclear
Minimize direct glareMinimize direct glare
Power Density RequirementsPower Density RequirementsPower density of no more than 1.6 Watts per square footPower density of no more than 1.6 Watts per square foot
Paint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsPaint StudioPaint StudioPaint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsPaint StudioPaint Studio
Pictures During Pictures During Construction PhaseConstruction Phase
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design SolutionDesign SolutionDaylight integrationDaylight integration
Indirect fixturesIndirect fixtures
Track SpotsTrack Spots
Automated curtain system for maximum Automated curtain system for maximum system control by occupantssystem control by occupants
Paint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Luminaire Type to meet Design SolutionLuminaire Type to meet Design SolutionFluorescent Indirect fixture with track lighting on the bottom fFluorescent Indirect fixture with track lighting on the bottom for or system flexibility.system flexibility.
Paint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsPaint StudioPaint Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsBuilding LayoutBuilding Layout
Dance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
LocationLocation11stst floor of the northfloor of the north--east east section of the buildingsection of the building
Space CharacteristicsSpace CharacteristicsSizeSize-- 3000 square feet3000 square feetMajor space propertiesMajor space properties
-- Special spring floorSpecial spring floor-- Acoustical drapesAcoustical drapes-- Batten system for theater/task Batten system for theater/task lighting located 21lighting located 21’’ above the above the floor floor
TasksTasksChoreograph dance routinesChoreograph dance routinesSmall dance showsSmall dance showsSetSet--up/Tear down for showsup/Tear down for showsPaper tasksPaper tasks
Dance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsDance StudioDance Studio
Pictures During Pictures During Construction PhaseConstruction Phase
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsDance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsDance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design CriteriaDesign CriteriaProvide a minimum illuminance of 40 fc on the floorProvide a minimum illuminance of 40 fc on the floor
Provide a visibly pleasing spaceProvide a visibly pleasing space
Allow for a flexible system in order to program different routinAllow for a flexible system in order to program different routineses
FlinnFlinn mode to achievemode to achieve-- clearclear
Power Density RequirementsPower Density RequirementsPower density of no more than 1.8 Watts per square footPower density of no more than 1.8 Watts per square foot
Dance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design SolutionDesign SolutionDown lights for the seating areaDown lights for the seating area
Luminaire to light up back wall Luminaire to light up back wall
Dance StudioDance Studio
Lighting Before and After a ShowLighting Before and After a Show
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsDance StudioDance Studio
Theatrical Lighting Provided by the UniversityTheatrical Lighting Provided by the University
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Luminaire Types to meet Design SolutionLuminaire Types to meet Design SolutionHID Luminaire to light up back wallHID Luminaire to light up back wall
CF Luminaire for seating areaCF Luminaire for seating area
Dance StudioDance Studio
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsBuilding LayoutBuilding Layout
LobbyLobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
LocationLocation33rdrd floor in the center of the buildingfloor in the center of the building
Space CharacteristicsSpace CharacteristicsSizeSize-- Approximately 4000 square feetApproximately 4000 square feetMajor space propertiesMajor space properties-- Finish stone floor in lobbyFinish stone floor in lobby-- Cantilevered awning over the entrances of the concert hall and Cantilevered awning over the entrances of the concert hall and theatertheater-- Wood wall finishWood wall finish
Main LobbyMain Lobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsMain LobbyMain Lobby
Pictures During Pictures During Construction PhaseConstruction Phase
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Lobby Plan ViewLobby Plan View
Main LobbyMain Lobby
Main TheaterMain Theater
Main Concert HallMain Concert Hall
EntranceEntrance
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsLobbyLobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsLobbyLobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
TasksTasksCirculationCirculation-- access to the main concert hall and main theateraccess to the main concert hall and main theaterSocial GatheringSocial GatheringReadingReadingSpecial events (art exhibits)Special events (art exhibits)
Design CriteriaDesign CriteriaMost important space in the buildingMost important space in the buildingProvide a visibly pleasing atmosphereProvide a visibly pleasing atmosphereFacial modeling is very important in the space with the Facial modeling is very important in the space with the interaction people in this spaceinteraction people in this spaceFlinnFlinn modes to achievemodes to achieve-- relaxed, spacious, and publicrelaxed, spacious, and public
Power Density RequirementsPower Density RequirementsPower density of no more than 1.8 Watts per square footPower density of no more than 1.8 Watts per square foot
Main LobbyMain Lobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design SolutionDesign SolutionDown lights through out the main corridorDown lights through out the main corridor
Down lights in the slanted ceilingsDown lights in the slanted ceilings
Up lights illuminating the slanted ceilingsUp lights illuminating the slanted ceilings
Cove light in above the main corridor and the two slanted ceilinCove light in above the main corridor and the two slanted ceilingsgs
Down lights to illuminate important doors in the space Down lights to illuminate important doors in the space
Main Main LobbyLobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Cove LightingCove LightingDown LightDown LightUp LightUp LightMain Lobby Down LightMain Lobby Down LightLighting During NonLighting During Non--Show TimesShow TimesLighting During Show TimesLighting During Show Times
Main LobbyMain Lobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Luminaire Types to meet Design SolutionLuminaire Types to meet Design SolutionCove Lighting Cove Lighting –– Fluorescent StripsFluorescent Strips
Down Lighting Down Lighting –– CF Down LightsCF Down Lights
Up Light Up Light -- HID Spots for light on slanted ceilingHID Spots for light on slanted ceiling
-- HID InHID In--floor floor UplightUplight
-- Industrial Fluorescent strips on canopies.Industrial Fluorescent strips on canopies.
Main LobbyMain Lobby
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsBuilding LayoutBuilding Layout
North North FacadeFacade
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
LocationLocationNorth side of the buildingNorth side of the building
Space CharacteristicsSpace CharacteristicsMajor space propertiesMajor space properties-- Round and jagged faRound and jagged faççadeade
-- Walls consist of glazing systems, Walls consist of glazing systems, masonry and different types of sidingmasonry and different types of siding
-- This side of the building faces one This side of the building faces one of the main roads on campus, of the main roads on campus, OslerOslerroadroad
TasksTasksVisibly pleasantVisibly pleasant
A sense of soaringA sense of soaring
North FacadeNorth Facade
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the ArtsNorth FacadeNorth Facade
Pictures During Pictures During Construction PhaseConstruction Phase
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design CriteriaDesign CriteriaProvide 5 fc in the horizontal and 3 fc in the vertical of illumProvide 5 fc in the horizontal and 3 fc in the vertical of illuminanceinance
A sense of soaringA sense of soaring
Make the building a landmark of excellence Make the building a landmark of excellence
Sharp horizontal lines at the round faSharp horizontal lines at the round faççade and vertical lines at the ade and vertical lines at the jagged fajagged faççadeade
Power Density RequirementsPower Density RequirementsPower density of no more than 0.25 Watts per square footPower density of no more than 0.25 Watts per square foot
North FacadeNorth Facade
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Design SolutionDesign Solution
North FacadeNorth Facade
Center for the ArtsCenter for the Arts Schematic Lighting ProposalSchematic Lighting Proposal Ben MittenBen Mitten
Center for the Arts
Luminaire Types to meet Design GoalLuminaire Types to meet Design GoalHID flood light to light upper area of buildingHID flood light to light upper area of building
HID lighting for under canopyHID lighting for under canopy
North FacadeNorth Facade