LORENZO PESCE
PLANIBEL TOP 1.0
OVER THE LAST 20 YEARS, AGC HAS GREATLY IMPROVED THE PERFORMANCE OF ITS LOW EMISSIVITY GLASS IN TERMS OF:
• APPEARANCE
• LIGHT & ENERGY CHARACTERISTICS
• QUALITY
• PROCESSABILITY
• EMISSIVITY
PLANIBEL TOP 1.0
AGC has developed several Low-E products to ensure that it regularly brings to market the best products featuring top performance:
• PLANIBEL PLUS
• PLANIBEL TOP
• PLANIBEL TOP N
• PLANIBEL TOP N+
PLANIBEL TOP 1.0
EMISSIVITY IS A KEY POINT
LOWER EMISSIVITY MEANS:
• Lower Ug Value
• Better thermal insulation value in DGUs used in future buildings
In June 2009 AGC will launch its new Low-E glass:PLANIBEL TOP 1.0
PLANIBEL TOP 1.0
The Low-E glass with the lowest emissivityvalue in the AGC range
0,01PLANIBEL TOP 1.0
0,03PLANIBEL TOP N+
0,04PLANIBEL TOP N
0,15PLANIBEL G
EMISSIVITYPRODUCT
PLANIBEL TOP 1.0
Position in the AGC Low-E range
PRODUCT Composit. position composition LT SF LR U-value
(90% ar)
U-value
(90% kr) 4-
10-4emissivity Temperable
TopN+ DGU #3 4-15-4 78 61 13 1,1 1,1 0,03 NO
TopN+T DGU #3 4-15-4 80 64 13 1,1 1,1 0,03 YES - must
TOP 1.0 DGU #3 4-15-4 70 50 20 1,0 1,0 0,01 NO
Energy N DGU #2 4-15-4 71 42 12 1,1 1,0 0,03 NO
Energy NT DGU #2 4-15-4 75 45 13 1,1 1,0 0,02 YES - must
G DGU #3 4-15-4 74 73 17 1,5 1,5 0,15 YES
TopN+ TGU #2 - #5 4-12-4-12-4 69 47 17 0,7 0,5 0,03 / 0,03 NO
Tri (CV) TGU #2 - #5 4-12-4-12-4 74 63 19 0,8 0,6 0,07 / 0,07 NO
Tri TGU #2 - #5 4-12-4-12-4 71 59 18 0,8 0,6 0,07 / 0,07 NO
PLANIBEL TOP 1.0
Light Transmission: 70% Psychological limit
Solar Factor: 50% Good Solar Protection
Light Reflection: 20% acceptable
Position in the AGC Low-E range
THE BEST Ug VALUE 1.0 W/mqK
PLANIBEL TOP 1.0
Available in multiple versions! REMIND!!!Planibel TOP 1.0 will be manufactured only in Cuneo
PLANIBEL TOP 1.0
TIEL CUNEO
5 tons 600 2.5 tons 600 2.5 tons 6003 3 34 X 4 X 4 X5 5 56 X 6 X 6 X8 8 8
10 10 10
STRATOBEL TOP 1.0
ATHUS CUNEO
5 tons 600 2,5 tons 600 2.5 tons 60033.1 X 33.1 X 33,1 X
44.X / 66.X ST1 44.X / 66.X ST1 33.X / 44.X / 66.X ST1
PLANIBEL TOP 1.0
Planibel Top 1.0 is not available in DLFs
Planibel Top 1.0 is not available in a toughenable version
Available on request:Planibel Top 1.0 on Clearvision
Stratophone Top 1.0
PLANIBEL TOP 1.0
AGC has a broad range of Low-E products, but…
• Which is the best product?
• Where should Planibel Top 1.0 be used instead of Planibel TRI?
• Where should Energy N be used instead of Planibel Top N+?
• Is the lowest Ug always the best solution?
…customers can feel “lost”.
PRODUCT Composit. position composition LT SF LRU-value(90% ar) emissivity
TopN+ DGU #3 4-15-4 78 61 13 1,1 0,03TOP 1.0 DGU #3 4-15-5 70 50 20 1,0 0,01Energy N DGU #2 4-15-4 71 42 12 1,1 0,03G DGU #3 4-15-4 74 73 17 1,5 0,15TopN+ TGU #2 - #5 4-12-4-12-4 69 47 17 0,7 0,03 / 0,03Tri TGU #2 - #5 4-12-4-12-4 71 59 18 0,8 0,07 / 0,07
PLANIBEL TOP 1.0
A simple rule to help customers:
While emissivity (Ug) should be minimal whatever the kind of building and the climate conditions, the Solar Factor should be considered in accordance with specific situations.
Basically 3 main applications should be taken into consideration:
PLANIBEL TOP 1.0
Commercial building (in Cooling and Heating Dominant condition):
• Low Ug Value & Low Solar Factor (Solar Protection):
• Energy N or Stopray Range
Residential building (in Heating Dominant conditions):
• Low Ug Value & High Solar Factor (Free Solar Heat Gain):
• Planibel TRI or Planibel Top N+
Residential building (Cooling Dominant conditions):
• Low Ug Value & Low Solar Factor:
• ENERGY N or Planibel TOP 1.0 or Planibel Top N+
PLANIBEL TOP 1.0
For Strong Cooling Dominant conditions: Stopray Range
Position in AGC Low-E range
Best Solution for Residential Buildings in“Heating
Dominant Conditions”
Best Solution for 1) all Commercial buildings 2) Residential in Cooling
Dominant condition
Excellent Solution forResidential Buildings in
“Cooling Dominant Conditions”
Good Solution for all Residential Buildings
Planibel Top N+ Energy N Planibel Top 1.0 Planibel Tri Made for DGU DGU DGU TGUCooling Dominant Conditions XX X X X X XXX X XHeating Dominant Conditions
Residential XXX XX XX XXXX
Commercial / conservatories XX XXXX XXX XX
Light Transmission X X X X X X X X X X X X XLow Reflection X X X X XXXX XX XXXProcessability XX XX XX XX
PLANIBEL TOP 1.0
The performance of Planibel TOP 1.0 vs. standard Low-E
glass (Planibel Top N+) in “Cooling Dominant Conditions”
was confirmed by a special study commissioned by AGC
and carried out by ITC (Istituto delle Tecnologie delle
Costruzioni), an independent Italian laboratory.
PLANIBEL TOP 1.0
INPUT
• Standard Italian house
• Location: Rome
• Heating & cooling Systems
OUTPUT
• Saving: 497 KWh/year
• Saving Cost:13%
PLANIBEL TOP 1.0
PROMOTIONAL MATERIALS
• www. yourglass.com: Product description, availability, glass configurator
• Brochure: new Low-E Range Brochure -Initially available in English
• PowerPoint presentation
PLANIBEL TOP 1.0
• PLANIBEL TOP 1.0 is ready for sales
• The Best Ug value in the AGC Range
• Good solar protection (SF =50%)
• Can be combined with AGC solar control glass (Stopsol &
Sunergy) to achieve Ug=1.0 W/(mqK) and to improve the final
SF for better solar protection
PLANIBEL TOP 1.0
• Planibel TRI remains the best solution for “Heating Dominant
Conditions”, while Planibel TOP 1.0 shows its full efficiency in
“Cooling Dominant Conditions”
• AGC has a full range of Low-E glasses and can supply customers
withy Low-E glass having Ug=1.0 W/(mqK)
• With its low U-value in DGUs, Planibel Top 1.0 can be useful in
helping, say, aluminium frame producers to comply with new
national regulations.
PLANIBEL TOP 1.0