PELICAN II - Brunswick County Government · 10" story board 6" corner board shingles as spec’d...
Transcript of PELICAN II - Brunswick County Government · 10" story board 6" corner board shingles as spec’d...
SHEET NO.
0.00
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
CO
VE
R S
HE
ET
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
BONUS ROOM
AB: Anchor BoltABV: Above AC: Air ConditioningACC: Access ACOUST: Acoustical ADH: Adhesive ADJ: AdjustAF: Arch FaultAFF: Above Finished Floor AGG: Aggregate ALM: Alarm ALT: AlternateALUM: Aluminum AMT: Amount ANCH: Anchor AP: Access Panel APPROX: Approximate ASPH: Asphalt AVG: Average
-It is the contractor’s responsibility to verify all details and dimensions
-All work shall be performed in accordance with all applicable national,state, and local codes and regulations.
-All dimensions are to rough frame of studs or to the outside of masonry.
-Final cabinet layout will be designed by cabinet supplier.
-All footings to be below frost line and must rest on undisturbed soilcapable of handling the building.
-All penetrations are to be sealed in accordance with state and localcodes.
-Insulate all Plumbing on exterior walls.
SYMBOL LEGEND
"FINISHED SQUARE FOOTAGE CALCULATIONS FOR THIS HOUSE WERE MADE BASED ON PLAN DIMENSIONS AND MAY VARY FROM
THE FINISHED SQUARE FOOTAGE OF THE HOUSE AS BUILT."
PELICAN II
BTW: Between BKR: Breaker BLDG: Building BLK: Block BLKG: Blocking BLT-IN: Built-In BM: BeamBOT: Bottom BRG: Bearing BRK: Brick BRKT: Bracket BRZ: Bronze BSMT: Basement
SQ.FT.
1st. FLOOR
H.B.
SQ.FT.
Architectural
Cover Sheet
1.011.021.031.042.012.023.014.015.015.02
Front ElevationLeft Side ElevationRight Side ElevationRear ElevationFirst Floor PlanBonus Floor PlanFoundation PlanRoof PlanFirst Floor Electrical PlanBonus Electrical Floor Plan
TABLE OF CONTENTS
P. LAM: Plastic Laminate PAR: Parallel
PROJECT SQUARE FOOTAGE
6
12 6/12
C/C: Center to Center CAB: Cabinet CAP: Capacity CAV: Cavity CER: Ceramic C.I.: Cast Iron CIR: CircleCJ: Control Joint CLG: Ceiling
ABBREVIATIONS
HB: Hose Bib HDR: Header HGT: Height HM: Hollow Metal HORIZ: Horizontal HW: Hot Water
CLG JT: Ceiling Joist CLO: Closet CLR: Clear CMU: Concrete Masonry Unit C.O.: Cased Opening COL: Column CONC: Concrete CPR: Copper CPT: Carpet CRS: CourseCTR: Center
EA: Each EJ: Expansion Joint ELEC: Electrical ENCL: Enclosure ENG: Engineer EQ: Equal EXH: Exhaust EXIST: Existing
DBL: Double DEG: Degree DEMO: Demolition DEPT: Department DH: Double Hung DIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: Dimension DISL: Disposal DN: Down DTL: DetailCW: Dish Washer DWG: Drawing
F TO F: Face to Face FA: Fire AlarmFAST: Fastener, FastenFB: Floor Break FD: Floor drain FDN: Foundation
GA: Gauge, Gage GALV: Galvanized GC: General Contractor GEN: General GFI: Ground Fault Interrupted GL: Glass GL BLK: Glass Block GLZ: Glaze GRND: Ground GT: Grout GYP: Gypsum GYP BD: Gypsum Board
IN: Inch INSUL: Insulation INT: InteriorINTERM: Intermediate
STD: Standard STL: Steel STOR: Storage STRT: Straight STRUC: Structural STRUCT: Structural SUR: SurfaceSYP: Southern Yellow Pine SYS: System
NOM: Nominal NTS: Not To Scale
PARTN: PartitionPDS: Pull Down StairPERIM: Perimeter PERP: Perpendicular PH: PhasePL: Plate PLAS: Plaster, Plastic PLBG: Plumbing PLTF: Platform PLYWD: Plywood PNT: Paint PORC: Porcelain PTN: Partition PWR: Power
JST: Joist JT: Joint
QTY: Quantity
TEL: Telephone THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: ToiletTR: TransomTRD: Tread TV: Television TYP: Typical
FGL: Fiberglass FIN: Finish, finishedFIXT: Fixture FLASH: Flashing FLG: Flooring FLG: Flange,FLR: Floor FLUOR: Fluorescent FP: FireplaceFRM: Frame FT: FootFTG: FootingFUR: Furring
TOTAL 2721
346
SQ.FT.
SQ.FT.
558
0
SQ.FT.
SQ.FT.
108
0.00 Cover Sheet
GENERAL NOTES
R & S: Rod and Shelf RA: Return Air RAD: Radius, Radiator RB: RubberREBAR: Reinforcing Bar RECP: Receptacle REINF: ReinforcementREF: Refrigerator REQD: Required RF: Roof RGH: Rough RM: Room RO: Rough Opening
SCH: Schedule SCR: Screen SECT: Section SF: Square Foot SHT: Sheet SHTHG: SheathingSHLVS: Shelves SHWR: Shower SIM: Similar SQ: Square SS: Stainless Steel
UNFIN: Unfinished UNO: Unless Noted Otherwise
VAC: Vacuum VERT: Vertical VIN: Vinyl VLT: Vault VNR: Veneer VT: Vinyl Tile VTR: Vent Through Roof
W/O: Without WD: Wood WH: Water HeaterW.I.C.: Walk In ClosetWIN: Window WP: WaterproofWRSTP: Weatherstripping
MARB: Marble MAS: Masonry MAT: Material MAX: Maximum MFD: ManufacturedMFR: ManufactureMIN: Minimum MIR: Mirror MISC: Miscellaneous MLD: Molding MO: Masonry Opening
O TO O: Out to Out OC: On Center OH: Overhead OPG: Opening OPP: Opposite OUT: Outlet OVFL: Overflow
KIT: Kitchen KP: Kickplate
LCFP: Light Ceiling Fan PackageLMS: Limestone LN: Length LNDG: LandingLNDRY: LaunrdyLNTL: Lintel LT: LightLTG: Lighting LTL: LintelLVL: Laminated Veneer Lumber
6.00
SECTION & DETAIL
ROOF SLOPE
SAMPLE
D-5.0
KEYNOTE
SHOWER HEAD
PERSPECTIVE REPRESENTATION
FLOOR BREAK
F.B.
HOSE BIB
Rendering may not match elevations or plans and is strictlya representation of a 3D model.
153
GARAGE
SQ.FT.120
2nd. FLOOR SQ.FT.
SQ.FT.
0
UNFINISHED BASEMENT
FRONT PORCH
BACK PORCH
1816
PATIO
Sections & Details
6.006.016.02
DetailsDetailsDetails
STEP FOUNDATION
...
...
...
...
GAS LINESHOWER NICHE
S.N.
1
REVISIONS
4 COURSE
3 COURSE
Reviewed For Code Compliance
SHEET NO.
1.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
FR
ON
T E
LE
VA
TIO
N
(LE
FT
CO
UR
TY
AR
D)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
8’-1 1
/2"
PARGE FOUNDATION
BRICK STEPS
4" BRICK ROWLOCK
7’-0
"6
’-6
"
10" STORY BOARD
HARDIE LAP SIDING
20"
20"
6’-9 1
/2"
METAL ROOF
10" COLUMNS(SEE DETAIL)
24’-2"
METAL AS SPEC’D
RIDGE VENT
SHINGLES AS SPEC’D
METAL ROOF
6" CORNER BOARD
10" HDR. W/ KEY
10" STORY BOARD
10" HDR. W/ KEY
7’-0
"
9’-1 1
/ 2"
SE
E T
RU
SS
PLA
NS
HARDIE SHAKES
2/0 X 4/0 WINDOW
HARDIE LAP SIDING
RIDGE VENT
PARGE FOUNDATION
FLUE PIPE& CHIMNEY
2’-0
"
BONUS FLOOR
BONUS CEILING/PLATE
BONUS WINDOW HEADER
GARAGE WINDOW HEADER
CEILING/PLATE HEIGHT
WINDOW HEADER
FINISH FLOOR (F.F.E.)
GARAGE CEILING/PLATE
FINISH FLOOR (F.F.E.)
12
12
12
1212
12
12
12
FINISH GRADE
APPROX. RIDGE HEIGHT
FINISH GRADE
DORMER WINDOW HEADER
1
1.01 SCALE: 1/4" = 1’-0"
FRONT ELEVATION (LEFT COURTYARD)
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
1.02
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
LE
FT
EL
EV
AT
ION
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
6" CORNER BOARD
4" BRICK ROWLOCK
10" STORY BOARD
10" HDR. W/ KEY &4" SIDES & SILL
TREATED WOOD HVAC SCREENING
HARDIE LAP SIDING 10" STORY BOARD
RIDGE VENTSHINGLES AS SPEC’D
7’-0
"
8’-1 1
/2"
HARDIE LAP SIDING
20"
20"
RIDGE VENT
6’-6
"
SE
E T
RU
SS
PLA
NS
HARDIE LAP SIDING
6" CORNER BOARD
SHINGLES AS SPEC’D
BRICK STEPS
7’-0
"
9’-1 1
/2"
2’-0
"
FLUE PIPE& CHIMNEY
FINISH FLOOR (F.F.E.)
WINDOW HEADER
CEILING/PLATE HEIGHT
12
8
GARAGE CEILING/PLATE
FINISH FLOOR (F.F.E.)
BONUS FLOOR
GARAGE WINDOW HEADER
12
8
FINISH GRADE FINISH GRADESIL-1.0
6.01
SID-SIL-1.0
HDR-1.0
6.01
SID-HDR-1.0
BONUS WINDOW HEADER
BONUS CEILING/PLATE
1
1.02 SCALE: 1/4" = 1’-0"
LEFT ELEVATION
...
...
...
...
Reviewed For Code Compliance
soffit to be backed with fire retardanttreated wood, 23/32" inch wood sheathing,or 5/8" inch gypsum board for all soffit lessthan 10' feet of side property lines perR703.11.3. ART 5.26.2016
SHEET NO.
1.03
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
RIG
HT
EL
EV
AT
ION
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
4" BRICK ROWLOCK
10" COLUMNS(SEE DETAIL)
20"
HARDIE SHAKE SIDING
RIDGE VENT
20"
6’-6
"
RIDGE VENT
7’-0
"
8’-1 1
/2"
SE
E T
RU
SS
PLA
NS
SHINGLES AS SPEC’D
10" HDR. W/ KEY& 4" SIDES
10" STORY BOARD
6" CORNER BOARD
SHINGLES AS SPEC’D
HARDIE SHAKE SIDING
RIDGE VENT
4" BRICK ROWLOCK
7’-0
"
9’-1 1
/2"
BRICK STEPS
6" CORNER BOARD
HARDIE LAP SIDING
PARGE FOUNDATION
10" STORY BOARD
6" CORNER BOARD
2’-0
"
FLUE PIPE& CHIMNEY
BONUS WINDOW HEADER
CEILING/PLATE HEIGHT
FINISH GRADEFINISH GRADE
12
8
12
8
12
8
12
8
FINISH FLOOR (F.F.E.)
GARAGE WINDOW HEADER
GARAGE CEILING/PLATE
BONUS FLOOR
BONUS CEILING/PLATE
WINDOW HEADER
FINISH FLOOR (F.F.E.)
1
1.03 SCALE: 1/4" = 1’-0"
RIGHT ELEVATION
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
1.04
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
RE
AR
EL
EV
AT
ION
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
6" CORNER BOARD
10" STORY BOARD
BRICK STEPS
4" BRICK ROWLOCK
PARGE FOUNDATION
SHINGLES AS SPEC’D
HARDIE LAP SIDING
7’-0
"
8’-1 1
/2"
20"
SE
E T
RU
SS
PLA
NS
RIDGE VENT
2’-0
"
7’-0
"
RIDGE VENT
FLUE PIPE& CHIMNEY
TREATED WOOD HVAC SCREENING
FINISH GRADE
FINISH FLOOR (F.F.E.)
WINDOW HEADER
CEILING/PLATE HEIGHT
BONUS FLOOR
BONUS CEILING/PLATE
BONUS WINDOW HEADER
12
6
12
6
1
1.04 SCALE: 1/4" = 1’-0"
REAR ELEVATION
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
2.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
FIR
ST
FL
OO
R P
LA
N
(LE
FT
CO
UR
TY
AR
D)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
2x6 WALL
6’-6"
3’-5
"2’-1
"
2x1
0
6’-1 1/2"
26
18
18
28
24
24
6’-0
"6
’-0
"
6’-1
1/2
"
5’-0
"
3’-0"
8070 OHD
5 1/2"
5’-6
1/2
"
SC
RE
EN
ED
P
OR
CH
8070 OHD
3’-1
1" SE
T W
IND
OW
HE
AD
ER
@ 6
’-6
" A
.F.F
.
6’-2 1/2"
21
’-0
"
11
’-8
"
3-34 x
80 -S
L
6’-2
"
1 x
4’S
TO
FIR
DO
WN
(1)- 2 x 10 SYP HDRFOR BOTH SIDES
11
’-8
"
50
’-6
"
27’-0 1/2"20’-6 1/2"8’-10"
8’-0"
9’-8
1/2
"
3’-7"
30 x76 -C
O
9/0
CL
G.
LVL BY TRUSS SUPPLIER
FB
ST
EP
4’-2"
FB
2x10x12 S
YP
24
3’-10"
2x10
x12
SYP
HB
36in
. Ven
ted
Pre
fab
F.P
.
(R.O
. = 3
7 1/
2 W
x 3
7 1/
2 H
)
24" LINEN CABINET
2x10x12 S
YP
60’-0"8’-0"
70’-0"
6’-8
"6
’-8
"
5’-0
"
FB
5’-0
"
2’-6
"5
’-1
1"
7’-1
"
5’-1
0"
2x1
0
2-205
’-1
0"
13
’-4
"
15’-5" 7’-9 1/2"
(2)-
2 x
10
HE
AD
ER
S
10
’-0
"
28 x
68 -1
5 LIT
E
3’-11" 4’-0"
TR-281
0
6’-6"
11
’-8
"
23’-5"
15
’-9
1/2
"
2’-0"
50
’-6
"
5’-5"
11’-10"3’-5"2’-4"
13’-1" 2’-0" 8’-1" 2’-0" 13’-1"
13
’-0
1/2
"
9’-5
"
11
’-1
"
FA
CE
OF
PO
RC
H
3’-8 1/2"
6’-3
"
3’-8
1/2
"
REF-SPACE
16
’-0
"
4’-3
"
6’-6
1/2
"
3’-10"
2’-0
" 3
’-2
"
3’-7
"
3’-5
"
3’-4
1/2
"
3’-0"
1’-9"
3’-2"
3’-1"
20’-6"
2’-4" 2’-5 1/2"
6’-0
"
3’-1
"
7
’-1
1/2
"5
1/2
"1
1’-2
1/2
"
19’-6"
6’-2
"
11
’-1
"
11’-3 1/2"
9 1/2"
28’-0"
5’-0"
10"
1
’-6
1/2
"3
’-5
"
40’-0"
70’-0"
9’-0
"
(2) 2
456
W.H
.
2’-8" 5’-4"
8’-0"2’-0"
10’-0"
15
’-6
"
28x7
6-CO
36
x4
8
(2) 2
456
(6)-
2 x
10
FLO
OR
JO
IST
16"
O.C
.
2x1
0
2x1
0
2x1
0
2x1
0
2x1
0
2x10
2x10
2x10
2x10
2x10
2x10
2x10
2x10
2x10
2x10
3’-7
1/4
"
2x10
2x10
2x10
DIM
EN
SIO
NS
TO
OU
TS
IDE
FR
AM
ED
HE
AD
ER
AB
OV
E
PA
TIO
NO
TE
:S
EE
TR
US
S P
LA
NS
FO
R G
AR
AG
EF
RA
MIN
G H
EIG
HT
/PLA
TE
HE
IGH
T
10’-0"
10
’-9
"9
’-8
"
20
’-5
"
2x10
12
’-0
"
GIR
DE
R T
RU
SS
GIR
DE
R T
RU
SS
2x10
GIR
DE
R T
RU
SS
10 x 8
0 (FG
)
5’-9"
LVL BY TRUSS SUPPLIER
2x1
0x1
0_
2Y
P
VAULT
FB
LV
L_
9.2
5x1
.75
2’-0
"
LV
L_
9.2
5x1
.75
4’-6 3/8"
5’-0"
3’-3 1/2"
6’-0"
10’-3"
9’-0
1/2
"2
’-0
"
2’-0" 11’-5" 2’-0"
FB
3 3
/16"
7’-6"
DW
RANGE
DRY SPWASH SP
MICRO.
42
x7
2
2’-1
1 1
/2"
2x1
0x1
0_
2Y
P
FB
28x7
6-CO
LV
L_
9.2
5x1
.75
4’-0"
2 8
5 1
/2"
2’-0"
1’-1
0"
2’-0
"7
’-1
0"
6’-3 1/2"
5’-3"
3’-6
"
UP
3’-7
1/2
"
14’-9 1/2"
2456
*(2) 2456
24
(3) 2
456
18
VAULT
2x6 W
ALL
8/0
HIG
HS
OF
FIT
26 PA
NE
LED
3’-9 1/2"
2-20
24’-8 1/2"
2x10x12 SYP
8’-3 3/8"
1’-4
"1
’-0
"3
’-3
"
1’-0"2’-0 1/2"2’-4 1/2"
45
" K
NE
EW
ALL
2x6 WALL
2456
Fir C
LG
. W
/1
X4
’S @
24
" O
.C.
18
’-1
0"
5’-5"
11
"1
0’-5
"
*2456
2x10x12 S
YP
SW
ING
VA
RIE
SIN
FIE
LD
2’-0
1/2
"
2’-2
1/2
"3
’-9
1/2
"
2x1
0
2x1
0
2x1
0
2x1
0
2x1
0
2x1
010
"
2x10x12 SYP 2x10x12 SYP
28
10’-7"
LA
UN
DR
Y
KIT
CH
EN
20
’-5
"
CA
SU
AL
DIN
ING
FO
YE
RM
AS
TE
RB
AT
H
FO
RM
AL
DIN
INGLIV
ING
RO
OM
BA
TH
#1
BE
DR
OO
M #
3
TW
O C
AR
GA
RA
GE
10 x 8
0 (FG
)4
’-1
1/2
"
11’-0"
2x10x12 S
YP
MA
ST
ER
BE
DR
OO
M
5’-5
"
10"
10"
9’-0"
CE
ILIN
G1
0’-0
" C
EIL
ING
11’-6"
4’-6"2’-6"4’-6"
2440-T
FR
ON
TP
OR
CH
2-20
7’-0
"6
"
BE
AM
FA
CE
AB
OV
E
FA
CE
OF
BLO
CK
BE
LO
W
6’-4"
3238 OFT
2’-0"2
x1
0x1
2_
2Y
P
2x10x8_2YP
2x1
0x8
_2
YP
TRASH
28 x 6
8
2’-0"
6’-4
"5
’-4
"17’-1"
26
(2) 2
456
*(3)
245
6
30 x 8
0 (FG
)7 1/4"
2450
2450
SEAT
TILE
2x10x12 S
YP
FB
2x10x12 S
YP
2x10x12 SYP
2x10x12 S
YP
2x10x12 SYP
2x10x12 SYP
HB
2x10x12 SYP
FB
9/0
CL
G.
BE
DR
OO
M #
2
1 R & 1 S
1 R
& 1
S
1 R
& 1
S
1 R
& 1
S
1 R & 1 S
1 R
& 1
S
5 SHLVS 1 R & 1 S
1 R
& 1
S
1 R & 1 S
5 SH
LVS
SCR-1.0
6.01
SCR-AL-10
WS-1.0
6.02
WS-1.0
SQ
U-1
0
6.00
35_S
Q_10_P
RG
1
2.01 SCALE: 1/4" = 1’-0"
FIRST FLOOR PLAN (LEFT COURTYARD)
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
2.02
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
BO
NU
S R
OO
M F
LO
OR
PL
AN
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
2’-6"
2x6
2 x
6 C
EIL
ING
JO
IST
24
" O
.C.
8/0 CEILING
2x6
24
6’-4
"
3’-1
"
(VERIFY FRAMING HEIGHT)
2 x 6 CEILING JOIST 16" O.C.
8/0 CEILING
78" WALL HEIGHT MIN.
2x6
4’-0" 9"
5’-6
"1
0’-0
"5
’-6
"
21
’-0
"
8/0 CEILING
5’-4"10’-0"7’-4 1/2"
5’-0"
TR
US
S M
FG
:P
RO
VID
E A
CC
ES
S T
HR
OU
GH
TR
US
SE
S F
OR
ST
OR
AG
E A
CC
ES
S
5’-0"
2’-0"
5’-1
0 1
/2"
3
’-2
"3
’-9
1/2
"
3’-6
"
DO
NO
T F
RA
ME
KN
EE
WA
LL
US
E T
RU
SS
’
SLO
PE
ST
OR
AG
E
RE
MO
VE
SH
EA
TH
ING
A
BO
VE
FO
R H
EA
DR
OO
M
3’-6
" GA
RA
GE
/HO
US
E
WA
LL
BE
LO
W
DO
NO
T F
RA
ME
KN
EE
WA
LL
US
E T
RU
SS
’
NO
TE
:V
ER
IFY
AL
L
INF
OR
MA
TIO
N W
ITH
T
RU
SS
PLA
NS
16’-9 1/2"
13
’-5
"
16
’-1
1"
HV
AC
LO
CA
TIO
N(V
ER
IFY
W/
SU
PE
RV
ISO
R)
SLO
PE
2x6
2x6
2x6
78" WALL HEIGHT MIN.
2x6
36
x4
8
DO
WN
24 x50 -
AC
CE
SS
2-14
2x10x12 SYP
2x10x12 S
YP
(2) 2846
(VE
RIF
Y F
RA
MIN
G H
EIG
HT
)
2446
5’-0"
5’-0
"5
’-0
"
SL
OP
ED
CE
ILIN
G
2’-0
"3
’-6
"
GIR
DE
R T
RU
SS
GIR
DE
R T
RU
SS
SE
AT
BO
NU
SR
OO
M B
1
2.02 SCALE: 1/4" = 1’-0"
BONUS ROOM FLOOR PLAN
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
2.03
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
AR
CH
ITE
CT
UR
AL
SIT
E P
LA
N
(LE
FT
CO
UR
TY
AR
D)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
BM
TR
TR
3
L=
40
.0
0’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’R
=5
0.
00’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’
N4
0°
46
’3
7"
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
PR
OP
OS
ED
DW
EL
LIN
G
#2
42
6F
FE
=20.6
7
BR
OO
ME
D C
ON
CR
ET
E D
RIV
EW
AY
(3000 P
SI)
GA
RA
GE
GF
E=
19
.00
CO
VE
RE
D P
OR
CH
CO
VE
RE
D P
OR
CH
PA
TIO
xqr;
UT
ILIT
Y A
RE
A (
WO
OD
WIT
H W
OO
D D
OO
R)
PG
=1
9.0
0E
G=
18
.53
X
MA
PL
E2
4
MA
PL
E1
2
OA
K6
OA
K7
OA
K6
OA
K6
OA
K8
PIN
E1
4
PIN
E1
0
PIN
E1
2
PIN
E1
0
PIN
E1
2
PIN
E1
1
PIN
E1
1
PIN
E8
PIN
E1
2
PIN
E1
2P
INE
11
PIN
E1
0
PIN
E1
2
PIN
E1
2
PIN
E1
4PIN
E1
1
PIN
E1
0
PIN
E1
0
PIN
E1
4
PIN
E1
2
PIN
E1
2
PIN
E1
2
PIN
E1
1
PIN
E1
1
PIN
E1
1
PIN
E1
2
PIN
E6
PIN
E8
PIN
E6
PIN
E6
PIN
E6
PIN
E8
PIN
E8
TV
8.
94’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’’
’’
WWW
30
’ F
RO
NT
YA
RD
SE
TB
AC
K
8’ SIDEYARD SETBACK
40’ W
ATE
RC
OU
RS
E E
AS
EM
EN
T
8’ SIDEYARD SETBACK
40’ W
AT
ER
CO
UR
SE
EA
SE
ME
NT
LO
T 2
4P
B 2
2 P
G 2
89
LO
T 2
5
PB
22
PG
28
9
VA
CA
NT
LO
TL
OT
23
P
B 2
2 P
G 2
89
VA
CA
NT
LO
T
N 21°30’11" E
174.20’
MA
PA
S C
OU
RT
60
’ P
RIV
AT
E R
/W
S 1
5°2
5’1
3"
E 75.0
7’
S 60°28’43" W 163.43’
60’
50
.5’
18.5’
40’
9’
40.1’
34’
16.3
’
26.2
’
18.3’
14.8’
32’
404 W
ET
LA
ND
LIN
E
IRF
IRF
IRF
IRS
19
18
18
18
18
18
17
17
17
16
16
16
ELE
V: 18.1
6
PK
-NA
IL
PG
=1
9.0
0E
G=
18
.32
PG
=1
9.0
0E
G=
18
.41
PG
=1
9.0
0E
G=
18
.39
PG
=1
9.0
0E
G=
17
.72
4.2
’
12’
10
’
12
’
15
’
EG
=1
7.7
5
EG
=1
7.9
3
XX
X
X
X
X
X
X
X
X
X
X
X
XX
XXX X
X
X
X
SE
WE
R S
ER
VIC
E
WA
TE
R S
ER
VIC
E
STAINED CONCRETE3000 PSI CONCRETE
3000 PSI CONCRETESTAINED CONCRETE
3000 PSI CONCRETE
FB
FB
HB
FB
REF-SPACE
W.H
.
36x48
FB
FB
DW
RANGE
DRY SPWASH SP
MICRO.
42x72
FB
UP
SEAT
TILE
FB
HB
FB
1
2.03 SCALE: 1" = 10’-0"
ARCHITECTURAL SITE PLAN
...
...
...
...
IMPERVIOUS CALCULATIONS
- 39346500 ACTUAL: 2566
HOUSE
=
SQF
ALLOWABLE:
OUTDOOR LIVING HARDSCAPS SQF
TOTAL SQF
2654
0000
3934
DRIVES & WALKS SQF
PATIO & TERRACES SQF
1164
116
POOLS/ LANAI (EXCLUDE WATER SURFACE) SQF0000
Reviewed For Code Compliance
SHEET NO.
3.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
FO
UN
DA
TIO
N P
LA
N
(LE
FT
CO
UR
TY
AR
D)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
21
’-0
"1
1’-8
"6
’-2
"1
1’-8
"
50
’-6
"
25’-0"35’-0"8’-0"
70’-0"
13
’-4
"
AP
PR
OX
IMA
TE
LO
CA
TIO
N
OF
TH
RE
AD
ED
RO
DS
, R
OD
S T
O B
E 1
2"
FR
OM
EA
CH
CO
RN
ER
AN
D8’-0"
O.C
. M
AT
AT
INT
ER
ME
DIA
TE
LO
CA
TIO
NS
10
’-0
"
2’-6
"1
3’-0
"
11
’-8
"
10’-0"
50
’-6
"
28’-0"40’-0"
70’-0"
2’-0"
2’-0"
4"
CO
NC
RE
TE
SL
AB
10’-0"
NO
TE
:D
RO
P G
AR
AG
E A
ND
E
XT
ER
IOR
SL
AB
S
BE
LO
W M
AIN
IN
TE
RIO
R S
LA
B A
S
SP
EC
IFIE
D B
Y
CO
NT
RA
CT
OR
.
9’-1
1 1
/2"
11
’-0
1/2
"
25’-0"3’-0"32’-0"
6’-2
"1
1’-8
"1
1’-0
1/2
"
4"
CO
NC
RE
TE
SL
AB
4"
CO
NC
RE
TE
S
LA
B
21
’-0
"
9’-1
1 1
/2"
AP
PR
OX
IMA
TE
LO
CA
TIO
N
OF
TH
RE
AD
ED
RO
DS
, R
OD
S T
O B
E 1
2"
FR
OM
EA
CH
CO
RN
ER
AN
D8’-0"
O.C
. M
AT
AT
INT
ER
ME
DIA
TE
LO
CA
TIO
NS
4"
CO
NC
. S
LA
B
12
’-0
"
7’-1
"
28 x
68 -1
5 LIT
E
4"
CO
NC
RE
TE
SL
AB
18
’-1
0"
5’-5"
2’-0"8’-3"2’-1"5’-5"
16
’-0
"
28 x 6
8
11
’-8
"
30 x 6
8 (FG
)
3-34 x
80 -S
L
4’-1"4’-0"
6’-8
"3
’-0
"
11
’-1
0 1
/2"
5’-1
1"
1’-0
1/2
"
6’-4"
2’-0" 8’-3"
11’-0"
5’-5
"
TRASH
RE
CE
SS
CO
NC
RE
TE
SLA
B 2
" A
T S
HO
WE
RLO
CA
TIO
N (
SE
E D
ET
AIL
)
2’-0" 5’-6" 2’-6"
2’-0" 8’-0"
OO
O
SID
-1.0
6.01
SC
R-S
ID-0
6
RS
-1.0
6.00
RS
-1.0
TH
R-0
1
6.00
DT
L-T
HR
-01
D-1.1
6.00
3-C-11
D-2
.1
6.00
3-C
-21
D-3.1
6.00
3-C-31
D-3.1
6.00
3-C-31
D-5
.2
6.00
3-C
-52
D-1
.1
6.00
3-C
-11
ST
R-2
.0
6.00
3C
_B
RI_
SID
D-4
.1
6.00
3-C
-41
W.H
.
REF-SPACE
FOUNDATION PLAN NOTES:1). Verify upgrades w/ supervisor.2). Provide conduit / wiring at slab.3). Threaded rods avg. 12" from all corners - AVOID 16" CENTERS
1
3.01 SCALE: 1/4" = 1’-0"
FOUNDATION PLAN (LEFT COURTYARD)
...
...
...
...
Reviewed For Code Compliance
SHEET NO.
4.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
RO
OF
PL
AN
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
6/12
12/12
2x8
6/12
2x8
2x8
2x8
12/12
12/12
2x8
2x8
2x8
8/1
2
2x6
2x6
2x6
2x6
2x62x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x8
2x8
2x8
2x8
2x10
2x8
1
’-6
"
13’-0 1/8" 2’-6"
11
’-2
3/4
"
FLU
E P
IPE
& C
HIM
NE
Y
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x8
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x8
2x62x8
2x8
VALLEY
VALLEY
VALLE
Y
VALL
EY
2x8 RIDGE
RIDGE VENT
2 x 10 RIDGE
2x8
2x6
2x8
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
RIDGE VENT
RID
GE
VE
NT
6’-1
1/4
"5
’-8
3/4
"
6/12
12/1212/12
8/1
2
8/1
2
8/1
2
6/12
8/1
2
DOR-5.0
6.01
DTL-DOR-05
EV
-1.1
6.00
EV
_S
ID_
1.1
2x10x12 SYP
2x10x12 S
YP
ROOF FRAMING NOTES:
EAVE:GABLE:DORMER (FRONT & SIDES)
1
4.01 SCALE: 1/4" = 1’-0"
ROOF PLAN
17"12"6"
1:2:
3:
4:5:6:7:
OVERHANG NOTES:
...
...
...
...
DIMENSIONS ARE FROM FACE OF FRAMINGROOF TRUSSES TO BE DESIGNED AND ENGINEEREDBY SUPPLIER VERIFY CONFIGURATION W/ TRUSS PLANS
TRUSSES TO DETERMINE OVERHANG FROM FACE OFEXTERIOR VENEER UNLESS NOTED OTHERWISE AT LOCATION
NOTIFY CONTRACTOR OF ANY PLAN DISCREPANCIESR=RIDGE, H=HIP, V=VALLEYVERIFY OPTIONSALL OVER FRAMED AREAS ARE TO MATCH THE SPACING
.4166 SOFFIT INLET
5" = 1.114 OUTLET
141.5
52.08
REQUIRED CALCULATIONS:
127 RIDGE LINEAL FT.1.114 RIDGE OUTLET
125
= .4166 INLET
PROVIDED:
x
x
52.08 141.5 OUTLETINLET +
INLET=
2374
RIDGE VENT
12" LINEAL FOOT
SOFFIT VENT 13.375"
LINEAL FOOT
ATTIC VENTILATION
12"
OUTLET=
= 193.58 NET FREE
-CALCULATIONS SHOWN CONSIDER VENTILATION USED AT LEAST 3 FEET ABOVE CORNICE VENTS.-CATHEDRAL CEILINGS SHALL HAVE A MINIMUM OF 1" CLEARANCE BETWEEN THE BOTTOM OF THE ROOF DECK AND THE INSULATION.
SOFFIT + RIDGE /
(1/150 = .006)
=ROOF SQ. FT.193.58
EAVE PERIMETER
.006
NC RESIDENTIAL CODE R806.2 MINIMUM AREA: THE TOTAL NET FREE VENTILATION AREA SHALL NOTBE LESS THAN 1/150 OF THE SPACE VENTILATED
PROVIDED NET FREE.082
REQUIRED NET FREE=
Reviewed For Code Compliance
FB
FB
HB
FB
REF-SPACE
W.H
.
36
x4
8
FB
FB
DW
RANGE
DRY SPWASH SP
MICRO.
42
x7
2
FB
UP
SEAT
TILE
FB
HB
FB
SHEET NO.
5.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
FIR
ST
FL
OO
R E
LE
CT
RIC
AL
PL
AN
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
L
F
LF
L
3S
S
LC
FP
D
10
’-6
"
TV
S
S
S
F
L
LF
S
CLGLV
CLGLV
L
F
TO
LIG
HT
AB
OV
E
C
AF
3
S
3
S
WP
WP
GFI
S
1 X
4
TV
S
S
AF
D D42"
3
S
SS
D
3
4S
SS
AF
S
S
AF
1 X 4
D
S
200
AM
P
S
TV
SC
42
"
D
PE
ND
AN
T
42"
L
SC
S
F
S
42"
F
S
3
8’-4 1/2"
27
’-0
"
TV
SS
1 X
4
S3
WP
42
"
S
3 3 FP
CO
ND
UIT
WP
3S
S
GF
I
S
TV
WP
AF
LCFP
D
GFI42"42"
GFI
AF
WP
D
S
3 S
S
SS
SS
LC
FP
S
3
S
SS3
S
S
PE
ND
AN
T
PE
ND
AN
T
GFI
SS
1
5.01 SCALE: 1/4" = 1’-0"
FIRST FLOOR ELECTRICAL PLAN (LEFT COURTYARD)
...
...
...
...
D3 S
CFP
HANGING
C
S
S3 S
4 S
D S
LCFP
Clg
GFI
DWP
TV
DF S
AFI
BATH STRIP LIGHT
FLUORESCENT PACKAGE
LIGHTED CEILING FAN PACKAGE
CEILING FAN PACKAGE
VANITY GLOBE LIGHT
U.C.
PENDANT
UNDER CABINET LIGHT FIXTURE
PENDANT LIGHT FIXTURE
SC
AMP
2 or 3 MULTIMEDIA OUTLET
CEILING FIXTURE - FLUSH MOUNT
STRUCTRUAL WIRE PANEL
ELECTRICAL PANEL
FLOOD LIGHT
BATH FAN
BATH FAN / LIGHT COMBO
HANGING CEILING FIXTURE
WALL FIXTURE SINGLE
RECESSED CAN LIGHT FIXTURE
EXTERIOR WALL FIXTURE
RECESSED EYEBAL CAN FIXTURE
Clg
SMOKE DETECTOR WALL/CLG
GENERAL NOTE:
ELECTRICAL FIXTURES, SWITCHES,
OUTLETS, ETC. ARE APPROXIMATE
LOCATIONS. LOCATIONS MAY VARY
BASEED ON FRAMING AND OR LOCAL CODE
DIMMER SWITCH -- FAN
DUPLEX OUTLET
CEILING OUTLET
GROUND FAULT INTERRUPT
FLOOR OUTLET
DOOR BELL & CHIMES
ARC FAULT INTERRUPT
TELEVISION OUTLET
DEDICATED OUTLET
WATERPROOF OUTLET
TELEPHONE OUTLET
SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
DIMMER SWITCH
SWITCH AND OUTLET
DIMMER SWITCH -- 3-WAY
GFI42
DUPLEX OUTLET - COUNTERTOP42
GROUND FAULT INTERRUPT - CNTRTOP
CARBON SMOKE DETECTOR WALL/CLG
CEILING OUTLET - LOW VOLTAGELV
MM2
S.W.P.
Reviewed For Code Compliance
2014 NEC.ART 5.26.2016
36
x4
8
DO
WN
SE
AT
SHEET NO.
5.02
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
BO
NU
S R
OO
M E
LE
CT
RIC
AL
PL
AN
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
S
FL
FL
TO
SW
ITC
H
BE
LO
W
LC
FP
AF TV
SSSS
42"
GF
I
SD
KE
YL
ES
S
SC
SS
3
1
5.02 SCALE: 1/4" = 1’-0"
BONUS ROOM ELECTRICAL PLAN (LEFT COURTYARD)
...
...
...
...
D3 S
CFP
HANGING
C
S
S3 S
4 S
D S
LCFP
Clg
GFI
DWP
TV
DF S
AFI
BATH STRIP LIGHT
FLUORESCENT PACKAGE
LIGHTED CEILING FAN PACKAGE
CEILING FAN PACKAGE
VANITY GLOBE LIGHT
U.C.
PENDANT
UNDER CABINET LIGHT FIXTURE
PENDANT LIGHT FIXTURE
SC
AMP
2 or 3 MULTIMEDIA OUTLET
CEILING FIXTURE - FLUSH MOUNT
STRUCTRUAL WIRE PANEL
ELECTRICAL PANEL
FLOOD LIGHT
BATH FAN
BATH FAN / LIGHT COMBO
HANGING CEILING FIXTURE
WALL FIXTURE SINGLE
RECESSED CAN LIGHT FIXTURE
EXTERIOR WALL FIXTURE
RECESSED EYEBAL CAN FIXTURE
Clg
SMOKE DETECTOR WALL/CLG
GENERAL NOTE:
ELECTRICAL FIXTURES, SWITCHES,
OUTLETS, ETC. ARE APPROXIMATE
LOCATIONS. LOCATIONS MAY VARY
BASEED ON FRAMING AND OR LOCAL CODE
DIMMER SWITCH -- FAN
DUPLEX OUTLET
CEILING OUTLET
GROUND FAULT INTERRUPT
FLOOR OUTLET
DOOR BELL & CHIMES
ARC FAULT INTERRUPT
TELEVISION OUTLET
DEDICATED OUTLET
WATERPROOF OUTLET
TELEPHONE OUTLET
SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
DIMMER SWITCH
SWITCH AND OUTLET
DIMMER SWITCH -- 3-WAY
GFI42
DUPLEX OUTLET - COUNTERTOP42
GROUND FAULT INTERRUPT - CNTRTOP
CARBON SMOKE DETECTOR WALL/CLG
CEILING OUTLET - LOW VOLTAGELV
MM2
S.W.P.
Reviewed For Code Compliance
2014 NEC.ART 5.26.2016
SHEET NO.
6.00
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
DE
TA
ILS
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)D-1.1
SCALE: 3/4"=1’-0"
EXT. GARAGE WALL SECTION
8"
24"
4" CONC. SLABGRADE
8" CONC. BLOCK
5/8" THREADED RODW/ STANDARD HOOK ENDS
AT 8’-0" O.C. MAX.
3000# CONC. FOOTING W/2) #5 REBAR CONTINUOUS
(MIN. 25" OVERLAP ATALL SPLICES)
2x8 TREATED
2x4 PLATE
OPTIONALINSULATION
D-2.1SCALE: 3/4"=1’-0"
INT. GARAGE/HOUSE WALL SECTION
4" CONC. SLAB
8" CONC. BLOCK
HEADER BLOCK
5/8" THREADED RODW/ STANDARD HOOK
ENDS AT 8’-0" O.C.MAX.
8"
24"
6 MIL VAPORBARRIER
D-3.1SCALE: 3/4"=1’-0"
SIDES & REAR HOUSE WALL SECTION
8"
24"
DOUBLE 2x4 PLATE, BOTTOMPLATE ONLY IS TREATED
GRADE8" CONC. BLOCK
EARTH FILL 5/8" THREADED ROD W/ STANDARD
HOOK ENDS AT 8’-0" O.C. MAX.
3000# CONC. FOOTING W/2) #5 REBAR CONTINUOUS
(MIN. 25" OVERLAP AT ALL SPLICES)
HEADER BLOCK
4" CONC. SLAB
6 MIL VAPORBARRIER
D-4.1SCALE: 3/4"=1’-0"
FRONT HOUSE WALL SECTION
8"
24"
DOUBLE 2x4 PLATE, BOTTOMPLATE ONLY IS TREATED
4" CONC. SLAB
GRADE8" CONC. BLOCK
EARTH FILL 5/8" THREADED ROD W/ STANDARD
HOOK ENDS AT 8’-0" O.C. MAX.
3000# CONC. FOOTING W/2) #5 REBAR CONTINUOUS
(MIN. 25" OVERLAP AT ALL SPLICES)
HEADER BLOCK
6 MIL VAPORBARRIER
D-5.2SCALE: 3/4"=1’-0"
PORCH DETAIL (REAR)
8"
2’-0"
8" CMU BLOCK
3000# CONC.FOOTING W/(2) #5 REBARCONTINUOUS(MIN. 25"OVERLAP AT ALLSPLICES)
1" OVERHANG
4" PORCH SLAB
BRICK ROWLOCK
10"
SQU
10 SCALE: 3/4"=1’-0"
SQUARE (10") FIBERGLASS COLUMN (3-5 CRS.)
SEEROOFPLAN
OVERHANG (COORDINATEW/ EAVE DEATIL)
PARGE COAT
3000# CONC. FOOTINGW/ 2 #5 REBAR
CONTINUOUS(MIN. 25"OVERLAP AT ALL SPLICES)
VERIFY HEADER NEEDED W/TRUSS PLANS
RAFTER TIE (COORDINATEW/ TRUSS PLANS)
(VA
RIE
S)
3"
8"
BRICK ROWLOCKW/ 1" OVERHANG
(VA
RIE
S)
12
(VA
RIE
S)
1’-5"
BEAM WRAP
FRAME LINE
24"
FRAME LINE
FOUNDATION HEIGHT VARIES.
COORDINATE WITH ALL PLANS
AND DETAILS.
-4 COURSE = 3 BLOCK
-5 COURSE = 4 BLOCKS
FUR OUTW/ 2XFRAMING@ 24" O.C.
P.T. 6X6 POST
(2) MTS TWISTSTRAPS
ABU 6x6 POST BASEW/ ANCHOR BOLT
FOOTER
COLUMN HEIGHT
BEAM BRG.
SEE TRUSS PLANS
0’-0" (F.F.E.)-0’-3" PORCH
STR
2.0 SCALE: 3/4"=1’-0"
STAIR DETAIL (3 COURSE BRICK/ SIDING ABOVE)
BRICK
BRICK
SLOPE
HOLD BAND BOARD1/2" OFF OF PORCH
3"
7" (MIN.) RISE
BRICK TREAD
4"
BRICK
1’-0"
ROWLOCK
BAND BOARD
CONC. SLAB
-(0’-3") PORCH
NATURAL GRADE
(0’-0’’) F.F.E.
-(2’-0’’) T.O.F.
0’-0" F.F.E.
VERIFY
FOUNDATION
W/ PLANS &
DETAILS
4"
SLOPE
THR
1.0 SCALE: 3" = 1’-0"
RECESSED SLIDER DETAIL
SLIDER THRESHOLD
BY MFR. COORD.
# OF PANELS W/
PLANS & ELEVATIONS
1"
RECESS CONC.
SLAB 1"
EXPANSION JOINT
(VERIFY W/ PLANS) RECESS CONC.
SLAB FOR SLIDER
# OF
PANNEL
SLIDER
SIZE
2
3
3
3
4
6/0 x 8/0
9/0 x 8/0
10/0 x 8/0
12/0 x 8/0
12/0 x 8/0
74"
110"
122"
146"
146"
2x6
2x8
2x8
2x8
2x10
WALL
THICKNESS
RECESSED
WIDTHC
OO
RD
INA
TE
W/
TR
US
S P
LA
NS
OPTIONAL GUTTER(COORD. W/ SPEC’S)
EV
1.1
EAVE - (VINYL BOXING/ PAINTED FRIEZE)
INSUL. AS SPEC’D
INSUL. AS SPEC’D
1/2" GYP. BD.
1/2" GYP. BD. CLG.
WEATHER RESISTANTBARRIER
(2) 2x4 TOP PLATE
2X4 STUDS @ 16" O.C.
SIDING (COOR. TYPW/ ELEVATIONS)
1/2" ROOF DECKING
RAFTER TIE COOR. W/TRUSS PLANS
ROOF SHINGLES AS SPEC’D
METAL DRIP EDGE FLASHINGW/ GUTTER
TRUSS ENGIN. BY MFR.
5/4 COMPOSITE FRIEZE BD.
VENTED VINYL SOFFIT
METAL COIL WRAP FASCIA
15 # ROOF FELT
1’-5"
12
SEEROOFPLAN
2x4 FRAMING 24" O.C.
RS
1.0 SCALE: 3/4"=1’-0"
RECESSED SHOWER SLAB DETAIL
GLASS PANEL
INSTALLCLIPS PER
MFR. SPECS.
CONT. CAULKJOINT
VARI
ESSE
E EL
EVAT
ION
8"
24"
EXTERIORFRAME LINE
HEADER BLOCKRECESS
CONC. SLAB 2"
GLASS PANEL @
SHOWER FLOOR
INT. WALL @
SHOWER FLOOR
EXT. WALL @
SHOWER FLOOR
2"
6 MIL VAPORBARRIER
WALL COOR.W/ FLOOR PLAN
MUD BED
TILE
TILEMUD BED
THICKENEDSLAB
(0’-0’’) F.F.E.
(-2’’)
Reviewed For Code Compliance
SHEET NO.
6.01
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
DE
TA
ILS
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
12SEE
ROOFPLAN
DOR
5.0 DORMER SILL DETAILSCALE: 1" = 1’-0"
(A-A) DORMER SECTION
METAL FLASHING
2X4 BLK’G. BTWN. TRUSSES
UNDER DORMER WALLS
@ 16" O.C.
11
"
DORMER SECTIONS & DETAILS (HARDIE)
15# FELT
METAL DRIP EDGE
(A.C) PLYWOOD GABLE
6" MIN
.
4’-0 1
/2"
(FR
AM
ED
OP
EN
ING
+/-
)
(B-B) CORNER/ JAMB DETAIL
SCALE: N.T.S.
WINDOW FLANGE
FLASHING
15# FELT UNDER
WINDOW & WIND.
FLANGE
SCALE: N.T.S.
2’-0 1/2" (FRAMED OPENING +/-)
6 1
/2"
2X LEDGER BD.
1/2" SEATHING
ICE & WATER SHIELD @
SLOPED AREAS TO LAP
8" MIN. HOR. & VERT.
METAL FLASHING
SCALE: 1" = 1’-0"WINDOW SHIM TYP.5’-5"
( F
RA
ME
D W
ALL H
GT
.)
12
1/2" ROOF DECKING
15# FELT
TRUSSES BY MFR.
WINDOW BY MFR.
2’-7 1/2" ( OUTSIDE OF DORMER FRAMING)
WINDOW SHIM TYP.
1X6 HARDIE TRIM BOARD
WINDOW FLANGE
2X4 FRAMING @ 16" O.C.
1/2" SEATHING
SHINGLES AS SPEC’D.
4 5/8" CROWN MOLDING FASCIA
CS 16 MTL. HURRICANE
STRAP(2 PER DORMER
SIDE WALLS)
ROOF TRUSSES BY MFR.
(2) 2X4 WINDOW HEADERS
R-30 ROOF INSULATION
15# FELT
1/2" SHEATHING
SLOPED METAL W/
BLOCKING @ 16" O.C.
4 5/8" CROWN MOLDING FASCIA
1X6 HARDIE FRIEZE
1/2" ROOF DECKING
METAL FLASHING
WINDOW BY MFR.
1X6 HARDIE TRIM BD.
METAL FLASHING
15# FELT ON TOP
OF 1/2" ROOF DECKING
R-13 INSULATION
LEDGER BOARD
2X4 BLK’G. BTWN.
TRUSSES UNDER
DORMER WALLS
@ 16" O.C.A-A
SEEROOFPLAN
B-B
ELEVATIONSECTION
SHINGLES AS SPEC’D
SIDING (COOR. W/ ELEV.)
15# FELT
1/2" SEATHING
15# FELT
1/2" SHEATHING
METAL DRIP EDGE
4 5/8" CROWN
MOLDING FASCIA
1X6 HARDIE FRIEZE
2X4 FRAMING @ 16" O.C.
ICE & WATER SHIELD @
SLOPED AREAS
RAFTER TIE COOR. W/
TRUSS PLANS
SIDING (COOR. W/ ELEV.)
ALUMINUM 4X4 STRUCTURALPOST
SCR
1.0 SCALE: 1/2"=1’-0"
ALUMINUM SCREENING (REAR PORCH)
ALUMINUM 2X2 INTERMEDIATEPOST
LEVEL 1
ALUMINUM 1X2 INTERMEDIATEHORIZ. MEMBER
4’-0" (MAX)
P.T. 2X4 BOTTOM RAIL 6’-4
"
SCR
1.0 SCALE: 3/4"=1’-0"
HVAC SCREENING (WOOD)
P.T. 2X6 TOP RAIL
METAL CAP
2’-0
"
1’-0"
GRADE
2"
P.T. 2X4 TOP RAIL
P.T. 1X4 VERTICALSLATS W/ 1" GABS
P.T. 4X4 POST(MAX 5’-0") O.C.
BOTTOM RAIL 2" (MAX.)FROM GRADE
CONC. FOOTER
6’-0
"
SIDING (COORDINATE
TYP W/ ELEVATIONS)
HDR
1.0 SCALE: 3" = 1’-0"
HEADER DETAIL (SIDING)
1/2" GYP. BOARD
WEATHER RESISTANT
BARRIER
CONT. SEALANT
TAPE OVER FLANGE
(2) 2X10 HEADERS
2X4 STUDS @
16" O.C.
PAINTED ALUMINUM
FLASHING
INSUL. AS SPEC’D
WEATHER RESISTANT
BARRIER TO LAP
OVER FLASHING
WINDOW TRIM
(COORDINATE W/
ELEVATIONS)
WINDOW BY MFR.
1/2" STRUCTURAL
SHEATHING
WINDOW SHIM
WINDOW FLANGE
CASING
SIL
1.0 SCALE: 3" = 1’-0"
SILL DETAIL (SIDING)
WINDOW SHIM
2X4 STUDS @
16" O.C.
INSUL. AS SPEC’D
1/2" GYP. BOARD
BACKER ROD
& CONT. SEALANT
CONT. SEALANT
CASING
WINDOW BY MFR.
WEATHER RESISTANT
BARRIER
1/2" STRUCTURAL
SHEATHING
SIDING (COORDINATE
TYP W/ ELEVATIONS)
WINDOW FLANGE
RUN WEATHER
RESISTANT BARRIER
UNDER WINDOW
WINDOW TRIM
(COORDINATE W/
ELEVATIONS)
TAPE OVER FLANGE &
BARRIER
Reviewed For Code Compliance
SHEET NO.
6.02
CTDRAWN BY
APPROVED BY
REVISIONS
ST
. J
AM
ES
, N
C
MB
DATE
THIS DRAWING IS THE PROPERTY OF LOGAN
HOMES AND IS NOT TO BE REPRODUCED OR
COPIED IN WHOLE OR PART WITHOUT
PERMISSION OF LOGAN HOMES COPYRIGHT 2012
CIT
Y:
DATE: 04/28/2016
EA-13-0024
ZIP
:
ST
RE
ET
:2
42
6 M
AP
AS
CO
UR
T
28
46
1
LA
YO
UT
:
JOB NUMBER:
REV
EW
AL
D R
ES
IDE
NC
EP
RO
JE
CT
:
DE
TA
ILS
(L
EF
T C
OU
RT
YA
RD
)
MO
DE
L:
PE
LIC
AN
II
(T
RA
DIT
ION
AL
HA
RD
IE)
SE
RIE
S:
BIR
D
OWNER INITIAL
DATE
I CERTIFY THESE DRAWINGS ARE CORRECT
IN THEIR ENTIRETY. I UNDERSTAND ALL
THE BASIC CONSTRUCTION DETAILS IN SO FAR
AS THEY ARE RELATIVE TO THE FLOOR PLAN
DESIGN, APPEARANCE AND FUNCTIONALITY
OF THE HOME. THESE PLANS REPRESENT THE
HOME CONTRACTED FOR. IN ADDITION, I
UNDERSTAND THAT THESE ARE THE FINAL
CONSTRUCTION DRAWINGS AND WILL
SUPERSEDE "EXHIBIT A" RENDERING & FLOOR
PLAN THAT WAS ATTACHED TO MY CONTRACT
AND OR ANY MODEL HOME THAT MAY HAVE
BEEN VIEWED. I UNDERSTAND THERE CAN BE
NO STRUCTURAL CHANGES AFTER THIS DATE.
DATE
FINAL INTERNAL REVIEW INITIAL /
(AFTER CUSTOMER SIGNATURE)
(VA
RIE
S)
2’-0"
SHINGLED AS SPEC’DOVER 15#
FELT OVER 1/2" SHEATHING
TRUSS BY SUPPLIER
RAFTER CLIPAS REQ’D
COORDINATE W/EAVE DETAL
INSULATION AS SPEC’D
1/2"
STRUCTURAL
SHEATHING
2x4 STUDS @16" O.C.
WEATHERRESISTANT
BARRIER
GRADE
SIDING (COOR. TYPW/ ELEVATIONS)
4" CONC.SLAB
EARTH FILL
8" CONC. BLOCK
3000# CONC. FOOTINGW/ 2) #5 REBAR
CONTINUOUS (MIN.25" OVERLAP AT
ALL SPLICES)
INSULATION AS SPEC’D
X
12
SEE PLAN
1/2" GYP. BD.
WS
1.0 SCALE: 3/4"=1’-0"
EXT. WALL SECTION (SIDING)
(VA
RIE
S)
5/8" THREADED RODW/ STANDARD HOOKENDS AT 8’-0" O.C.MAX.
15 1/2"
FOUNDATION HEIGHT VARIES.
COORDINATE WITH ALL PLANS
AND DETAILS.
-4 COURSE = 3 BLOCK
-5 COURSE = 4 BLOCKS
DOUBLE 2x4 PLATE,BOTTOM PLATEONLY IS TREATED(SEAL BOT. PLATEFOR AIRINFILTRATION)
6 MIL VAPORBARRIER
(0’-0’’)
F.F.E.
T.O.F.
CEILING/PLATE HGT.
Reviewed For Code Compliance