Passive house Project
Myself and five other peers from different disciplinary backgrounds were selected to
attend a Passive House retrofit project in Denmark. Upon arrival we were briefed with
the task that follows. Working with other nationalities such as: Portuguese, Hungarian, Estonian, French, Lithuanian and Danish from all specialist backgrounds. Once
divided into 12 groups of 5 we were set to achieve a common goal of retrofitting a
typical traditional Danish residential complex to meet passive house standards.
![Page 2: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/2.jpg)
THE
Agnė Matuliauskaitė - Project Manager
Alexander Nesbitt - Architectual
Technologist
Dorka Beke - Architect
João Patrício Silva - Architect
Margus Krasnov - Civil Engineer
![Page 3: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/3.jpg)
SITE
![Page 4: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/4.jpg)
CHOSEN
![Page 5: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/5.jpg)
EXISTING
![Page 6: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/6.jpg)
INITIAL
![Page 7: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/7.jpg)
EXISTING BUILDING
![Page 8: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/8.jpg)
FINAL PROPOSAL
![Page 9: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/9.jpg)
EXISTING
0. GROUND FLOOR -1. BASEMENT
1. FIRST FLOOR 2. SECOND FLOOR
![Page 10: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/10.jpg)
PROPOSAL
0. GROUND FLOOR
-1. BASEMENT
2. SECOND FLOOR
1. FIRST FLOOR
3. TOP FLOOR
![Page 11: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/11.jpg)
CROSS
![Page 12: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/12.jpg)
PROPOSAL
![Page 13: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/13.jpg)
BUILDING
VENTILLATION SYSTEM
Fresh air without dust, and pollen
Decrease thermal losses
Don’t have to install too high-capacity
heating-cooling system
INTERIOR DESIGN
Make low changes
Some modification in the bathrooms and in
the kitchen.
SERVICE
Each staircase has a riser connected to four
flats.
In the basement we have to move the
bathroom to have easy connection to the
risers.
![Page 14: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/14.jpg)
SOLAR
SOLAR HEATING: THE SUN IS TOO
LOW IN DENMARK
WEATHER OFTEN CLOUDY
PHOTOVOLTAICS PV PANELS TO
SUPPORT THE ELECTRICITY
SUPPLY
SYSTEM: Quick Step Solar PV
![Page 15: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/15.jpg)
SYSTEM: QUICK STEP SOLAR
Dimensions: 2000 mm x 365 mm Weight: 19.10 kg Module area: 0.73 m2 Module output: 68 Wp ± 10 % Operating voltage: VMPP= ca. 14.20V Operating current: IMPP= ca. 4.80 A Open circuit voltage: VOC= 17.10 V Short circuit current: ISC= 5.12 A Connection: MC- box, 600 mm wire included
SOLAR
![Page 16: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/16.jpg)
GROUND SOURCE
HORIZONTAL SURFACE
COLLECTOR
ENOUGH SPACE TO INSTALL
CAN BE USED FOR HEATING AND
COOLING TOO
DOESN’T DEPEND ON WEATHER
COEFFICIENT OF PERFORMANCE IS
GOOD
![Page 17: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/17.jpg)
HEATING
CLOSED LOOP VERTICAL GROUND
SOURCE HEATING SYSTEM
ENERGY INPUT IS REDUCED AND
LARGER RADIATORS USED TO
INCREASE EFFICENCY WITHOUT
REDUCING PERFORMANCE
![Page 18: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/18.jpg)
BIOMASS
HIGH EFFICENCY
CARBON NEUTRAL SYSTEM (IN OPERATION)
USED ONLY TO SUPPLEMENT
HEAT PUMPS FOR DOMESTIC
WATER
![Page 19: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/19.jpg)
MV
Minimum fresh air flow rate per
person
30 x 4 x 8 = 960 m3/h
kitchen ventilation x bathroom ventilation x
W/C+ minimum fresh air = overall air flow
rate
Overall air flow for the building
60 x 40 x 20 + 960= 1440 m3/h
![Page 20: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/20.jpg)
MECHANICAL
BASEMENT PLAN
![Page 21: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/21.jpg)
GROUND FLOOR PLAN
MECHANICAL
![Page 22: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/22.jpg)
FIRST FLOOR PLAN
MECHANICAL
![Page 23: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/23.jpg)
BUILDING
GREY WATER RECYCLING
Collect rain for watering our green roof
Enough space for the water tank under
the roof.
WATER STORAGE GREY
WATER
Collect water from the
sink, and from the
shower for the toillet.
![Page 24: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/24.jpg)
ROOF
BY CHANGING THE SHAPE OF THE ROOF
WE HAVE ENOUGH SPACE TO CREATE A
GREEN TERRACE
1. Optigreen seed mixture type E Good seed mix composition and various coordinated breeds of plantation.
2. Extensive substrate type E * (5-20 cm)
Multi-layer extensive green roof design coordinated substrate
with high water storage capacity.
3. Filter mat type 105 Water flow near a high ability
to prevent the leaching of
fine soil particles.
4. Optigreen drainage system FKD 40 (4 cm) Quickly drain excess water preventing water swelling Balancing filter diffusier
5. Optigreen protective and water-holding geotextítia It protects the root or a film. the roof membrane from damage and keeps the water. A filter
removes soil from the water to prevent gutter blockage.
![Page 25: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/25.jpg)
COST
TOTAL COST : 3 890 000 eur OR 29 175 000Kz
![Page 26: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/26.jpg)
ENERGY
![Page 27: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/27.jpg)
EXISTING BUILDING
IDA Indoor Climate and Energy vers. 4.22
License: IDA40:ED134
Simulated by Margus
Date 20.04.2012 19:46:31 [436]
ENERGY
![Page 28: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/28.jpg)
IDA Indoor Climate and Energy vers. 4.22
License: IDA40:ED134
Simulated by Margus
Date 20.04.2012 19:46:31 [436]
EXISTING BUILDING
ENERGY
![Page 29: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/29.jpg)
Existing building
Renovated building
83.5 %
ENERGY
![Page 30: Passive House Project](https://reader030.fdocuments.us/reader030/viewer/2022013103/568c0fa81a28ab955a94ef2f/html5/thumbnails/30.jpg)