PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco...
Transcript of PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco...
PASSENGER ELEVATORS
C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017
Eco Changes is the Mitsubishi Electric Group’s environmental statement,and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society.
Visit our website at:http://www.MitsubishiElectric.com/elevator/
Mitsubishi Electric elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on safety first, our elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort. The technologies and skills cultivated at the Inazawa Works and 13 overseas manufacturing factories are utilized in a global network that provides sales, installation and maintenance in support of maintaining and improving product quality.As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations, proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity.
State-of-the-Art Factories…For the Environment. For Product Quality.
Mitsubishi Electric de Mexico, S.A. de C.V. has acquired ISO 9001 certification from the International Organization for Standardization based on a review of quality management.The plant has also acquired the certification of INDUSTRIA LIMPIA, based on the audit of corresponding program.
Certification
Revised publication effective Sep. 2017Superseding publication of C-CL1-6-C9896-A Oct. 2016
Specifications are subject to change without notice.
1
Based on our policy, “Quality in Motion”,
we provide elevators and escalators that will
satisfy our customers with high levels of
comfort, efficiency, ecology and safety.
Principle
We strive to be green in all of our business activities.We take every action to reduce environmental burden during each process of our elevators’ and escalators’ lifecycle.
Application for Type MR
Contents
… technologically advanced elevators that consume less power,
have minimal impact on the global environment and harmoniously serve people
and buildings with smooth, seamless operation. The refined design produces a
high-quality atmosphere that reassures passengers of the superior safety and
comfort synonymous with Mitsubishi Electric products. Regardless of the use or
purpose, the NEXIEZ is a best-match solution for virtually any elevator installation.
Welcome to a New Era in Vertical TransportationIntroducing the NEXIEZ...
1.75
1.0
(kg)
(m/sec)
Main Features 3-4
Car Designs 5-8
Hall Designs 9-10
Features 11
Entrance Layout Drawing 13-14
Electrical Installation 12
Basic Specifications for Type MR 15-16
Basic Specifications for Type MRL 17-18
450 550 700 750
Application for Type MRL
1.75
1.0
(kg)
(m/sec)
450 630 825
2
NEXIEZ-GPXType MR
NEXIEZ-GPXType MRL
Our long-term commitment to developing energy-efficient elevators has created systems and functions that make intelligent use of power.
Using Energy WiselyNEXIEZ-GPX comes in two types: configurations with and without machine room (Type MR and Type MRL). Choose the configuration that is better suited for the space and other building conditions.
Flexible Elevator Layout
Emergency Situations
Milestones of Energy-saving Technologies in Elevator Development
Traction machine
Motor drive
Control circuit
Power consumption /CO2 emissions*3
Motor Permanent magnet motor
Gearless
20102000
199019801970
VVVF controlACVV *1 controlAC2 control
MicrocomputerRelay
30%
37%74%93% 100%
*2
Worm geared
Induction motor
–70%Approx.
43
Used for ceiling lights, LEDs boost the overall energy performance of the building. Furthermore, a long service life eliminates the need for frequent lamp replacement.
LED Lighting
Traction Machine with PM Motor (PM motor: Permanent magnet motor)
The joint-lapped core built into the PM motor of the traction machine features flexiblejoints. The iron core acts like a hinge, which allows coils to be wound around the core more densely, resulting in improved motor efficiency and compactness.A high-density magnetic field is produced, enabling lower use of energy and resources and reduced CO2 emissions.
Ceiling: L500
● Advantage of LEDs
Service life (hr) Power consumption (W)
Approximately 20 times longer Approximately 88% reduction
LED
Incandescentlamp
40000
2000
LED
Incandescentlamp
14.4
132
*2
Ceiling: L500 LED downlights
Main Features
The top machine room, accommodating bulky equipment, allows simple and flexible equipment layout to fit the hoistway into a limited space in the building.
All equipment is installed in the hoistway. Without the machine room, the space on the hoistway gives architectures and interior designers greater freedom in design.
Type MR(MR: Machine room)
Type MRL(MRL: Machine-room-less)
Firefighters’ Emergency Operation (FE) (Optional)When the fire operation switch is activated, the car immediately returns to a predetermined floor. The car then responds only to car calls which facilitate firefighting and rescue operations.
Fire Emergency Return (FER) (Optional)When a key switch or a building’s fire alarm is activated, all cars immediately return to a specified floor and open the doors to facilitate the safe evacuation of passengers.
Earthquake Emergency Return (EER-S) (Optional)When a secondary wave seismic sensor is activated, all cars stop at the nearest floor and park there with the doors open to facilitate the safe evacuation of passengers.
Normalpowersupply
Motor
Switch
Emergencypower supply
Control panel
Firefighter
To a specifiedfloor
Normalpowersupply
Motor
Switch
Emergencypower supply
Building’s fire alarmor return signalfrom supervisory room
Control panel
To a specifiedfloor
Normalpowersupply
Motor
Switch
Emergencypower supply
Seismicsensor
Control panel
To the nearestfloor
Car Designs (1/2)
65 Actual colors may differ slightly from those shown.
N510
The ceiling height of the car shown in this design image is 2600mm.
L500
N530
N520
Car Design ExampleWallsTransom panelDoorsFront return panelsKickplateFlooringCar operating panel
- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- M2-F06 [Roca Grafito]- Type LCD
Ceiling: [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black)Lighting: Downlights (LEDs)
Car Design ExampleWalls
Transom panelDoors
Front return panelsKickplateFlooringCar operating panel
Ceiling: [Center] Milky white acrylic panel [Sides] Painted steel sheet (Black)Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs)
- Decorative plastic finish : M2-D24 [Chang (RA)]- Brushed stainless-steel- Decorative plastic finish : M2-D24 [Chang (RA)]- Brushed stainless-steel- Brushed stainless-steel- M2-F04 [Terrazo Blanco]- Type LED
Car Design ExampleWalls
Transom panelDoors
Front return panelsKickplateFlooringCar operating panel
- Decorative plastic finish : M2-D16 [Carvalho Cinza (TX)]- Brushed stainless-steel- Decorative plastic finish : M2-D16 [Carvalho Cinza (TX)]- Brushed stainless-steel- Painted steel sheet- M2-F03 [Terrazo Crema]- Type LCD
Ceiling: [Center] Painted steel sheet (Black) [Sides] Painted steel sheet (White)Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs)
Car Design ExampleWalls
Transom panelDoors
Front return panelsKickplateFlooringCar operating panel
Ceiling: [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black)Lighting: Fluorescent lamp Downlights (LEDs)
- Decorative plastic finish : M2-D23 [Cherry (MC)]- Brushed stainless-steel- Decorative plastic finish : M2-D23 [Cherry (MC)]- Brushed stainless-steel- Brushed stainless-steel- M2-F05 [Terrazo Humo]- Type LED
L500with center fan type
(Optional)
Car Operating Panels Materials and Colors
FinishesInterior
87
Notes:*1: Appearing fixing method of face plate is slightly different in elevator type. Please consult our local agents for more details.*2: The entrance width (JJ) shall be 800mm. For JJ=900mm, please consult our local agents.
Buttons accented with LED halo illumination
Illuminated characters (CBV1), arrows (PIV1) and halosattract user’s attention.
YH-59S
YZ-52A
HandrailMirror
Yellow-orange lighting
Tactile
Stainless-steel withnon-directional brushed f inish
Illuminationcolor
M2-D05Titan (TX)
M2-D16Carvalho Cinza (TX)
M2-D19Thuja (LG)
M2-D20American Oak (LG)
M2-D04Silver Oak (MC)
M2-P01Gris Moteado
Base C
M2-P02Gris Verdoso
Moteado
M2-P03AlmendraGofrado
M2-P04Marron
Brillante
M2-P05NaranjaBrillante
M2-P06Rojo Brillante
M2-P07Industrial
Almendra Satinado
M2-P09Verde Brillante
Brushed finish
Walls, doors and Transom panel
Stainless-steel
Decorative plastic finish (only for Walls & doors)
Painted finish
Rubber tile
Vinyl tile
Elevator type
Type MR
P08-2S
All
P11-COP11-2S
P06-2SP08-CO
Front returnpanel
Front returnpanel
Side wallType MRL
Code No.Location of
car operating panel*2*1
Configuration
Car Designs (2/2)
Walls*1
*2
Brushed stainless-steelDecorative plastic f inishPainted steel sheetBrushed stainless-steelPainted steel sheetBrushed stainless-steelDecorative plastic f inishPainted steel sheetBrushed stainless-steelPaintBrushed stainless-steelDurable vinyl tilesDurable rubber tilesMarble (Supplied by customer)Extruded hard aluminum
Application Required Color No.
Transom panel
Doors
Front return panel
Kickplate
Flooring
Sill
Notes: *1: A half-size mirror on the rear wall is available as an option. *2: Only available in dark gray.
- Applicable - Please consult our local agents.
Type LED Type LCD
M2-D21Walnut Minnesota (TX)
M2-D22Sucupira (TX)
M2-D23Cherry (MC)
M2-D24Chang (RA)
M2-D07Nogal (MC)
M2-D25Natura (TX)
M2-D18Almond (TX)
M2-D17Taupe (TX)
Flooring
M2-F01Roca Caliza
M2-F02Roca Ceniza
M2-F03Terrazo Crema
M2-F04Terrazo Blanco
M2-F05Terrazo Humo
M2-F06Roca Grafito
M2-F09Emeflex Rally
Negro
M2-F10Emeflex Rally
Gris
M2-P08Azul Brillante
M2-P10Gris Nopal
Mate
Brushed finish
Stainless-steel
109
Hall Designs
M2-P01Gris Moteado
Base C
M2-P02Gris Verdoso
Moteado
M2-P03AlmendraGofrado
M2-P04Marron
Brillante
M2-P05NaranjaBrillante
M2-P06Rojo Brillante
M2-P07Industrial
Almendra Satinado
Doors and jamb
Painted finish
Materials and ColorsE-102 Narrow Jamb E-302 Splayed Jamb
PIV1-C710 PIV1-C720 PIV1-C766 PIV1-C776
Hall Position Indicators and Buttons Finishes
JambDoorsHall position indicatorand hall button
- Brushed stainless-steel- Brushed stainless-steel
- PIV1-C710
Jamb
Doors
Hall position indicatorand hall button
- Painted steel sheet : M2-P08 [Azul Brillante]- Painted steel sheet : M2-P08 [Azul Brillante]
- PIV1-A710
JambBrushed stainless-steel
Painted steel sheet
Painted steel sheet
Brushed stainless-steel with logo etchingBrushed stainless-steel
Extruded hard aluminum
Doors
Sill
Application Required Color No.
Note: - Applicable - Please consult our local agents.
PIV1-A710 PIV1-A720
M2-P08Azul Brillante
M2-P09Verde Brillante
M2-P10Gris Nopal
Mate
Electrical Installation
Power Feeder Data
for Type MR
for Type MRL
Feeder Size Calculation
● The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C. 1.25 (Note) × FLU (A)
(FLU (A): current during upward operation with full load at power supply voltage of 200V)Note: For Type MR, the value is 1.05 for the elevator with the rated capacity 700kg or more and the rated speed 1.75m/sec.
The wire length for the feeder size must be calculated via the following formula.Wire length (m) Coefficient* × E (V)/FLAcc (A)(E: power supply voltage (V))(FLAcc (A): current while accelerating with full load at power supply voltage of 200V)
*Refer to the table below for coefficients.
● When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied by the corresponding diversity factor below.
● The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side.● The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side in the elevator machine room or hoistway.
< =
No. of elevators/groupDiversity factor
2
2.0
Feeder size (mm2)Coe�cient
3.5
6.3
5.5
9.7
8
13.8
14
23.9
22
35.9
30
46.4
38
57.6
50
71.3
60
85
80
105
100
126
125
146
150
166
200
192
250
218
325
244
*
Capacity(kg)
Ratedspeed
(m/sec)
Current at 200V
FLU (A) FLAcc (A)
NF size inmachine room
(A)1.01.0
1.751.0
1.751.0
1.75
2.83.45.94.37.64.68.1
16193023382440
26315239654170
4575869
20304030403050
Motoroutput
(kW)
Capacity ofpower supply
(kVA)700850
15001100190012002050
Heatemissions
(W)450
550
700
750
FLU: current during upward operation with full load at power supply voltage of 200V.FLAcc: current while accelerating with full load at power supply voltage of 200V.
Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula. (FLU/FLAcc current (A) at E (V)) = (Current at 200V) × (200/E (V))
Capacity(kg)
Ratedspeed
(m/sec)
Current at 200V
FLU (A) FLAcc (A)1.01.0
1.751.0
1.75
2.83.76.55.18.9
1520332542
2534584475
45769
2030403050
Motoroutput
(kW)
Capacity ofpower supply
(kVA)740960
152011901930
Heatemissions
(W)450
630
825
1211
Features
Notes: • 1C-2BC (1-car selective collective), 2C-2BC (2-car group control) • = Standard = Optional = Not applicable • #1: NS for 1C-2BC: Up to 20 stops, NS for 2C-2BC: Up to 16 stops • #2: Cannot be combined with ITP, EMB. • #3: When ITP is applied, Emergency Alarm Bell is .
Breaker incontrol panel
(A)
Operational and Service FeaturesFeature Abbreviation 1C-2BC 2C-2BC Required
CCBK -GCBK - -HCBK -CCC -
CFO-A
CLO-A
COS - -EVRC-C
FCC-P
IND -NXL -
NSCR-C
NS
HOS
OLH -SFL -
Group Control Features
Feature Abbreviation 1C-2BC 2C-2BC Required
FFS
TFS
MFP
SOHS - -
Door Operation Features
Feature Abbreviation 1C-2BC 2C-2BC Required
DSAC -DLD -NDG -
DODA -- -
ROHB -RDC -
Signal and Display Features
Feature Abbreviation 1C-2BC 2C-2BC Required
AECC
CID-S
CTBZ
-
-
-
-
-
AAN-G
Emergency Operations and Features
Feature Abbreviation 1C-2BC 2C-2BC Required
Earthquake Emergency Return EER-S
Emergency Car Lighting ECL -Fire Emergency Return FER
Fire�ghters’ Emergency Operation FE
Mitsubishi Emergency Landing Device MELD
Operation by Emergency Power Source – Automatic only OEPS-SA
PIM-C
Next Landing
Non-service to Speci�c Floors – Switch #1
Non-service Temporary Release for Car Call – Card Reader Type
Car Call Canceling
False Call Canceling – Car Button Type
Continuity of Service
Elevator remote control – Car
Car Light Shut O� – Automatic
Car Fan Shut O� – Automatic
Out-of-service by Hall Key Switch
Backup Operation for Car Control Microprocessor
Backup Operation for Group Control Microprocessor
Backup Operation for Hall Control Microprocessor
Safe Landing
Overload Holding Stop
Independent Service
Main Floor ParkingMain Floor Changeover OperationForced Floor Stop
Strategic Overall Spotting
Door Sensor Self-diagnosis
Automatic Door Speed Control
Door Load Detector
Door Nudging Feature – With Buzzer
Repeated Door-close
Multi-beam Door Sensor
Reopen with Hall Button
Car Top Buzzer
Car Arrival Chime – Car
Car LCD Position Indicator
Voice Guidance System
Inter-communication System ITP
Hall LCD Position Indicator
Emergency Alarm Bell #3
#3
1413
Entrance Layout Drawing
CO (Center Opening) 2S (Side Opening)
E-102
E-102 E-302 E-102 E-302
E-102 E-302 E-102E-102 E-302
4 50
30 55
55 30
38
10100 100
150
Finished wall(by owner)Si
ll su
ppor
t(b
y ow
ner)
Entrance width: JJ
Fini
shW
all
7025 5
10
300
(Min
. cle
aran
ce)
Entra
nce
heig
ht: 2
100
30°
30
55
140
60
E-302
4
30
303055
55
25
80°
Jam
b de
pth:
m
in. 1
30
Finished wall(by owner)
Sill
supp
ort
(by
owne
r)
Entrance width: JJFini
sh
150 150150
Keyhole Keyhole
1200
B
Entrance width:
JJ150
Finishedfloor level
B
120
100
120
100
150
Finishedfloor level
1200
BB
7010 35
20
30°
30
55
140
60
90
300
(Min
. cle
aran
ce)
Entra
nce
heig
ht: 2
100
AA
AA
Door elevation (section A-A)Door plan (section B-B)Door elevation (section A-A)Door plan (section B-B)
Hoistway entranceHoistway entrance
Sill
supp
ort
(by
owne
r)Si
ll su
ppor
t(b
y ow
ner)
(Min
. cle
aran
ce)
(Min
. cle
aran
ce)
E-302
Entra
nce
heig
ht: 2
100
Entra
nce
heig
ht: 2
100
Entra
nce
heig
ht: 2
100
Entrance width: JJ
Entrance width: JJ
Keyhole
JD
70
5
2510
30 140
60
30°
300
7010 35
20
30
9130°
140
60
150
300
150
1200
25
100
100
A
A
BB
91
91 30
25 150
Fini
sh
Jam
b de
pth:
m
in. 1
30
Min. 50
30
75~113
10°
Wall
50
91
91
30
1038
100 100150
Fini
sh
Finished wall(by owner)
Finished wall(by owner)
Finishedfloor level
Entrance width:
JJ
Entra
nce
heig
ht: 2
100
Keyhole
1200
B
150
B
100
100
A
A
Finishedfloor level
Entrance width:
JJ
Entra
nce
heig
ht: 2
100
Entra
nce
heig
ht: 2
100
Entrance width:
JJ
Horizontal Dimensions
Reaction Loads
1615
Basic Specifications for Type MR
Hoistway Plan
Hoistway width: AH
Entrancewidth: JJ
Car internalwidth: AA
Car i
nter
nal
dept
h: B
B
Hoi
stw
ay d
epth
: BH
JJ
AA
AH
BHBB
Machine Room Plan
2122202422252325222522262627282929
Rear
SideRearSideRearSideRearSideRearSideRearSideRearSide
Side
1616141915171516151716191920212223
2122222425242625242525262627292930
991110121013912913101111121313
53 46
61 51
61 52
61 51
61 52
70 58
68 56
77 64
1400×850
1100×1100
1400×1030
1100×1400
1400×1250
1350×1400
450
550
700
750
6
8
10
11
1.0
1.0
1.75
1.0
1.75
1.0
1.75
1.01.75
800*1
800
800*1
800
800*1
800
CO
2S
CO
2S
CO
2S
1400×850
1100×1100
1400×1030
1100×1400
1400×1250
1350×1400
1750×14001600×17501800×15301750×15902100×14601600×20501800×18301750×18102100×16002050×1800
RearRear*2
Side*2
RearSide
Rear*2
Side*2
RearSideSide
1850×27001800×29801850×20501850×29002100×20501800×32801850×22001850×31002100×20502050×2200
□□□□□□□□□□
P6
P8
P10
P11
6
8
10
11
450
550
700
750
1.0
1.01.75
[Terms of the table]• This table shows standard specifications without counterweight safety. Please consult our local agents for other specifications.[Note]*1: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.
Vertical Dimensions
1.01.75
2200 2500*16070
44004630
13601410
450, 550, 700, 750550, 700, 750
1.01.75
202200 2500*16070
44004630
13601410
450, 550, 700, 750550, 700, 750
[ Terms of the table]• This table shows standard specifications without the fireproof landing door and counterweight safety. Please consult our local agents for other specifications.• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.[Notes]*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local aqents for details.*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.
Required
Counter-weight
position
Reaction loads(kN)
R1 R2 R3 R4 R5 R6
Shown for CO doorsCounterweight rear drop
Shown for 2S doorsCounterweight rear drop
Shown for 2S doorsCounterweight side drop
R1
R3
R2
R4
Machine room clear width: AM
Machine room clear width: AM
Machine room clear width: AM
R1
R2
R3
R4
Mac
hine
room
dep
th: B
M
Control panel
Power-receiving box (by owner)
Lighting outlet (by owner)
Lighting outlet (by owner)
Lighting outlet (by owner)
Power outlet (by owner)
Power-receiving box (by owner)
Power outlet (by owner)
Power outlet (by owner)
Acc
ess
door
Wid
th: 7
00H
eigh
t: 2
000
Acc
ess
door
Wid
th: 7
00H
eigh
t: 2
000
Access doorWidth: 700
Height: 2000
Mac
hine
room
dep
th: B
MM
achi
ne ro
om d
epth
: BM
Vent
ilati
on
grill
eVe
ntila
tion
gr
ille
Ventilator(by owner)
Ventilator(by owner)
Ventilator(by owner)
データ不明
R1
R2
R3
R4
JJ
AH
BH BB
AA
Hoistway Section
Mac
hine
roo
m c
lear
hei
ght:
HM
2200
Ove
rhea
d: O
H
Entr
ance
hei
ght:
HH
2100
(sta
ndar
d)
Cei
ling
heig
ht23
00 (s
tand
ard
)
Trav
el: T
R
Floo
r to
floo
r he
ight
Pit
dep
th: P
D
R5 R6
Note: Hoistway section for counterweight side drop is slightly different from this figure.
Power-receiving box (by owner)
Ventilation grille
Control panel
Control panel
R5
R5R6
R6
R5
R6
1817
Basic Specifications for Type MRL
Horizontal Dimensions
[ Terms of the table]• This table shows standard specifications without the fireproof landing door and counterweight safety. Please consult our local agents for other specifications.• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.[Notes]*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local agents for details.*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.
800
800*
800*
2SCO2SCO2S
950×1300
1100×1400
1350×1400
1500×17401800×17201650×18002025×17201900×1800
Side
P6
P8
P11
6
8
11
450
630
825
1.0
1.01.75
Reaction Loads
Vertical Dimensions
314348
233335
182628
618092
526876
223235
950×13001100×14001350×1400
450630825
6811
1.01.0
1.75
[ Terms of the table]• This table shows standard specifications without counterweight safety. Please consult our local agents for other specifications.[Notes]*1: If the capacity is 630kg and marble (supplied by customer) is selected for flooring finish, the dimension may be changed. Please consult our local agents for details.*2: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.
1.0
1.75
2500*2
TR 3030 TR 60
TR 3030 TR 60
3850*1
3900*1
39003950
405041004150
145015001550
1300*1
135020
450, 630
825
450, 630, 825
<=
<=
<=
<=
<
<TR 30
30 TR 6060 TR 70
<=<=<<=<
□□□□□
Required
Reaction loads(kN)
R1 R2 R3 R4 R5 R6
Shown for 2S doors Counterweight side drop
Shown for CO doors Counterweight side drop
Hoistway width: AH
Car i
nter
nal
dept
h: B
B
Hoi
stw
ay d
epth
: BH
Entrancewidth: JJ
Car internalwidth: AA
AH
BB BH
JJ
AA
R5
R5
R1
R1
R2
R2
R3
R3
R4
R4
R6
R6
Ceili
ng h
eigh
t23
00 (s
tand
ard)
Floo
r to
floor
hei
ght
Pit d
epth
: PD
Ove
rhea
d: O
H
Entr
ance
hei
ght:
HH
2100
(sta
ndar
d)
Trav
el: T
R
R5 R6
Hoistway Plan Hoistway Section