Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

22
Oxidation Ditch Upgrade Energy Savings While Increasing Peak Flows November 19, 2014 Ryan Brauen, P.E.

Transcript of Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

Page 1: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

Oxidation Ditch UpgradeEnergy Savings While Increasing Peak

Flows

November 19, 2014Ryan Brauen, P.E.

Page 2: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Agenda

• Background• Improvements• Funding• O2 Ditch Rehab• Energy Findings• Performance• Lessons Learned• Questions

WWTP

WRRFWater Resource Recovery Facility

Page 3: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Location – Greentown, IN

Page 4: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Project Need

• Age• Enforcement

– Sewer Ban: 1997• Early Warning: 1994• Hyd. Overloading (112%)• Bypasses (38)• TSS, NH3, P

– Agreed Order: 2006• Hyd. Overloading• SSO’s• Bypasses (25)• E. Coli, NH3

Need

Age

AgreedOrder

SewerBan

Page 5: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Approach

2006: Collection System Field Investigations

2009: Collection System Rehabilitation

2009-2011: Flow Monitoring

2011-2012: WRRF Design

2013-2014: WRRF Construction

Page 6: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Design Constraints

• Design Data– ADF: 0.58 MGD– PHF: 2.85 MGD– cBOD5: 180 mg/l– TSS: 220 mg/l– NH3-N: 30 mg/l– P: 7 mg/l

• NPDES Limits– cBOD5: 10 mg/l– TSS: 12 mg/l– NH3-N: 1.1 mg/l

(summer), 1.6 mg/l (winter)

– P: 1.0 mg/l– pH, D.O., E. Coli

Page 7: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Existing Facility

• 1963: Original Facility

• 1990: O2 Ditch, Intra-Channel Clarifier, UV

• 2000: Screening, Raw Sewage Pumping, Surge Tank (EQ)

Page 8: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Improvements

• New Influent Sewer• Screening• Raw Sewage Pumping• Plant Piping• EQ Blowers & Flow

Control• Chem P• O2 Ditch Mods• Flow Splitter

• Secondary Clarifiers• RAS/WAS Pumping• UV & Post Air• Aerobic Digesters &

Blowers• Sludge Dewatering• SCADA• Generator

Page 9: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Funding

• SRF• Green Project Reserve

– Rain Gardens ($24,500)

– Riparian Buffer ($8,400)

– Plumbing ($900)

– D.I. Pipe ($325,000)

– Glass Block ($2,000)

– Lighting/Switches ($13,600)

– VFD’s ($51,200)

– O2 Ditch System ($161,000)

Page 10: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Existing O2 Ditch & Clarifier

• Installed 1990• 2 – 40 Hp Rotors• Intra-Channel

“Boat” Clarifier– Regular Solids

Washout– Limited Control– Reduced Tank

Volume

Page 11: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Improvement – Option 1

• Replacement Rotors– 2 – 30 Hp Rotors– Sys. Eff. = 90%– VFD’s– D.O. Control

Page 12: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Improvement – Option 2

• Bio-Loop®

– 3 – 25 Hp PD Blowers– Motor Eff. = 90%– VFD Eff. = 98%– Fine Bubble

Membrane– 2 – 2.7 Hp

Submersible Mixers• 49 rpm• ~6-ft. dia. Blades

– D.O. Control

Page 13: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Improvement – Selection

• Bio-Loop® Selected– Past Rotor Issues– Energy Savings– Flexibility– Cold Weather Ops– Lower Capital Cost

Page 14: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Energy Evaluation - Existing

• 2 – 40 Hp Rotors• 13 Hrs/day (6.5

hrs/rotor)• Eff. = 80% (est.)• $0.08/kWh• ~$39/day• $14,235/yr.

Page 15: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Energy Evaluation – Option 1 Replacement Rotors

• Aeration Control– 2 – 30 Hp Rotors– 16.2 Hp req./rotor– VFD turn down– 24 Hr./day/rotor– Sys. Eff. = 90%– $0.08/kWh– ~$52/day– $18,900/yr.

• Mixing Control– 2 – 30 Hp Rotors– 9 Hp req./rotor– VFD turn down– 24 Hr./day/rotor– Sys. Eff. = 90%– $0.08/kWh– ~$29/day– $10,585/yr.

Page 16: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

O2 Ditch Energy Evaluation – Option 2Bio-Loop®

• 2 Mixers – 24/7– Eff. = 90% (est.)

• SCADA– Blower Runtime– Blower Hz– 5/2014 – 9/2014

• $0.08/kWh• Avg. $16/day• $5,840/yr.

Page 17: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Oxidation Ditch – Energy Comparison

Existing Rotors(As Operated)

Replacement Rotors

(Aeration Limited)

Replacement Rotors

(Mixing Limited)

Bio-Loop(Actual)

Avg. Day $59 $52 $29 $25Avg. Month $1,770 $1,560 $870 $750Avg. Year $14,235 $18,900 $10,585 $9,12520 Years $284,700 $378,000 $211,700 $182,500

Annual Savings ($5,110) ($9,775) ($1,460) $020 Yr. Savings ($102,200) ($195,500) ($29,200) $0

Page 18: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Effluent Quality – Post Construction

Design

MRO2/2014 – 9/2014 %

RemovalInfluent EffluentInfluent (MGD) 0.580 0.303 --- --cBOD5 (mg/l) 180 182 4.9 97.3%TSS (mg/l) 220 227 3.2 98.6%NH3 (mg/l) 30 22 0.36 98.4%P (mg/l) 7 4.2 0.50 88.1%

Page 19: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Lessons Learned

• Existing Tankage• Baffle Walls• Air Curtain

– Scum/Foam• Blower Sizing

Page 20: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Summary

• Flows – Design: 0.42 MGD 0.58 MGD– Peak: 1.5 MGD 2.85 MGD

• 14-50% Energy Savings• Lower Capital Cost• Operational Flexibility• Compatible with Bio-P• Cold Weather Ops

Page 21: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Summary

Energy Savings Opportunities Existand Can Be Realized at Small Facilities

Page 22: Oxidation Ditch Upgrade Engery Savings While Increasing Peak Flows

IWEA 2014 Oxidation Ditch Upgrade – Energy Savings While Increasing Peak Flows

Questions?

Thanks to:Town of Greentown