OUR VISION – YOUR SOLUTION THE WORLD’S NUMBER 1 GLAZED SECURE VISION PANEL VISTAMATIC® is a world leading designer and manufacturer of glazed secure vision panels used in hundreds of hospitals, medical facilities, high security environments, corporations and universities across the world. For over 25 years, we’ve innovated window panel design and technology to meet your commercial needs. Our innovative technology, wide range of options, design formats and product applications mean that architects, designers and door manufactures find simple, durable, refined and affordable solutions to fit the unique requirements of their projects. Today, our product presence is across the world with our two factory locations in Europe and Florida. With the opening of our US factory based in Florida, all our panels are now US manufactured. Where possible we are using local materials - therefore decreasing our carbon footprint and increaseing our Green capabilites. Our success derives from producing reliable, high quality products which meet the exact requirements of our customer’s unique needs. Our unique panels incorporate three sheets of glass set within an insulated unit, operated by using either a lever or knob mechanism. Turn the lever; raise the inner sheet of glass for observation. Turning the handle back; vision is obscured.

description

 

Transcript of Our Vision

OUR VISION – YOUR SOLUTION

THE WORLD’S NUMBER 1 GLAZED SECURE VISION PANEL

VISTAMATIC® is a world leading designer and manufacturer of glazed secure vision panels used in hundreds of hospitals, medical facilities, high security environments, corporations and universities across the world.

For over 25 years, we’ve innovated window panel design and technology to meet your commercial needs. Our innovative technology, wide range of options, design formats and product applications mean that architects, designers and door manufactures find simple, durable, refined and affordable solutions to fit the unique requirements of their projects. Today, our product presence is across the world with our two factory locations in Europe and Florida.

With the opening of our US factory based in Florida, all our panels are now US manufactured. Where possible we are using local materials - therefore decreasing our carbon footprint and increaseing our Green capabilites.

Our success derives from producing reliable, high quality products which meet the exact requirements of our customer’s unique needs. Our unique panels incorporate three sheets of glass set within an insulated unit, operated by using either a lever or knob mechanism. Turn the lever; raise the inner sheet of glass for observation. Turning the handle back; vision is obscured.

Vistamatic® glazed secure vision panels are easy to fit and are maintenance free; available in a variety of sizes and custom made to fit unique specification and observation requirements. Panels are available with optional protection against X-Ray, laser, vandalism, fire and even bullets. Panels can be designed to incorporate blackout, corporate logos insignia.

A SMALL SELECTION OF VISTAMATIC® PROJECTS IN THE US AND ACROSS THE WORLD

NORTH AMERICA

Gaston Memorial - Psychiatric Ward (North Carolina)Memorial Sloan Kettering cancer Center (New York)Goodall Hospital (New Hampshire)Jennie Stuart Medical Center (KY)Miami Valley Hospital (Ohio)Rush University Hospital (Illinois)JPS Health Network (Texas)Wake Forest University Baptist Medical Center (North Carolina)Hills Pet Building (Topeka, KS)St Mary's Hospital (MD)Jefferson County International (Des Moines, IA)Doctors Community Hospital (Maryland)Franklin Memorial Hospital (Maine)EA Conway Medical Center (Louisiana)Via Christie Regional Medical Center (Kansas)Broward General Hospital (Florida)Sentra Virginia Beach General Hospital (Virginia)University of Wisconsin Hospital (Wisconsin) Banner Health (Phoenix, Arizona)Denver Health Pavilion M (Colorado)Caritas Project (Connecticut)Masonic Medical Center (Illinois)Northwest Community Hospital (Arlington Heights, Illinois)Methodist ER Expansion (Indianapolis, Indiana)University of Louisville Ambulatory Surgical Suite (Kentucky)Quincy Medical Center (Quincy, Massachusetts)Sinai Hospital (Baltimore, Maryland)Washington Hospital (Glen Burnie, Maryland)Kennedy Hospital (Cherry Hill, New Jersey)OSF Healthcare Systems (Escanaba, Michigan)VA Alexandria (Louisiana) VA WhiteRiver (Vermont)North Mississippi Medical Center (Tupelo, Mississippi)Muskogee Hospital (Muskogee, Oklahoma)Johnston Children’s Hospital (Johnson City, Tennessee)Texas Orthopedic Hospital (Houston, Texas)St. Luke’s Hospital (The Woodlands, Texas)Meriter Hospital (Madison, Wisconsin)Whishard Hospital (Indianapolis)Parkland Hospital (Texas)Silver Cross Hospital (Chicago)

REST OF THE WORLD

Yantoluo Foundation Project (Amazon Jungle Peru)Addenbrookes HospitalAlder Hey Children’s HospitalChelsea & Westminster HospitalGreat Ormond Street HospitalGuys & St Thomas HospitalHammersmith HospitalHarley Street ClinicJohn Radcliffe InfirmaryLeeds Teaching HospitalNorfolk & Norwich HospitalOxford Radcliffe HospitalRoyal Edinburgh HospitalSt Bartholomew’sStoke MandevilleThe London ClinicThe Royal Marsden HospitalThe Wellington ClinicKalba Hospital, (Kalba, Sharjah)Fuajairah Maternity Hospital (Fujairah)The London Hospital (Kuwait)The Saad Hospital (Saudi Arabia)King Fahd Medical City (Saudi Arabia)The King Faisal Hospital (Riyad, Saudi Arabia)The Mafraq Hospital (Abu Dhabi)Oxford Street Enhanced Health Facility (Trinidad)

MUNICIPAL, CORPORATE CENTER AND INSTITUTIONAL PROJECTS:

Heartland Acres Event Center (Iowa)Baltimore Airport Fire Station (Maryland)Heartland Acres (Independence, Iowa)UC-M3 Psych Renovation (Chicago, Illinois)Maryland Aviation Administration Fire House (Baltimore, Maryland)Portland International Airport (Portland, Maine)Wentworth Douglas (Sanbornton, New Hampshire)Fletcher Thomspon Architects (Somerset - New Jersey)Paddington Green Police StationWormworth Scrubs Prison

PRODUCT INFORMATION

VISTAMATIC® is committed to research and development of superior vision panel technology in a multitude of options, to provide the perfect solution for healthcare, educational, municipal and institutional facilities, event centers, and corporate environments.

VISTAMATIC® product line is available in a variety of dimensions to meet the needs of projects where privacy, security, and quiet observation are required. The products are all custom manufactured, examples of some standard sizes include but are not limited to:

10" x 10" 12" x 12" 18" x 18" 6 ¼" x 20" 6 ¼" x 30" 36" x 36" 48" x 48"

The smallest width we provide is 6 1/4" and the largest size is 48"

TYPES OF GLASS AVALABLE:

Lead (X-Ray), Laser Polymer, Bullet Resistant, Firelite NT (45 Minute Rating), Pyroguard C730 Safety Glass (20 Minute Rating), Tempered (All Thicknesses), Laminated (All Thicknesses), Pyrosec 3/4" Glass (For very secure units)

VS1 Max = Vistamatic Glazed Secure Vision panel with one side handle, sandblasted linesVS2 Max = Vistamatic Glazed Secure Vision panel with two side handle, sandblasted linesVS1 SuperMax = Vistamatic Glazed Secure Vision panel with one side handle, sandblasted linesVS2 SuperMax = Vistamatic Glazed Secure Vision panel with two side handle, sandblasted linesVW1 Max = Vistamatic Glazed Secure Vision panel with one side handle, White Vinyl Lines (Blackout)VW2 Max = Vistamatic Glazed Secure Vision panel with two side handle, White Vinyl Lines (Blackout)VW1 SuperMax = Vistamatic Glazed Secure Vision panel with one side handle, White Vinyl Lines (Blackout)VW2 SuperMax = Vistamatic Glazed Secure Vision panel with two side handle, White Vinyl Lines (Blackout)VB1 Max = Vistamatic Glazed Secure Vision panel with one side handle, Black Vinyl Lines (Blackout)VB2 Max = Vistamatic Glazed Secure Vision panel with two side handle, Black Vinyl Lines (Blackout)VB1 SuperMax = Vistamatic Glazed Secure Vision panel with one side handle, Black Vinyl Lines (Blackout)VB2 SuperMax = Vistamatic Glazed Secure Vision panel with two side handle, Black Vinyl Lines (Blackout)VG1 Max= Vistamatic Glazed Secure Vision panel with one side handle, Grid Sandblasted PatternVG2 Max= Vistamatic Glazed Secure Vision panel with two side handle, Grid Sandblasted PatternMax XL1 = Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines, bottom ½ solid sandblastMax XL2 = Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines, bottom ½ solid sandblastVistaport1 = Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines, 15 ¾ DiameterVistaport2 = Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines, 15 ¾ DiameterSlide1 = Vistamatic Glazed Secure Window with one side handle, sandblasted Vertical linesSlide2 = Vistamatic Glazed Secure Window with two side handle, sandblasted Vertical lines

Maximum Sizes:

Vistamatic Max™ 40 x 40 with Impact Absorption System (Vista-Glide™)Vistamatic SuperMax™ 48 x 48 with Impact Absorption System (Vista-Glide™)Vistamatic Vistaport™ 15 ¾ (One size only)Vistamatic Vista-Slide™ 60 x 40Vistamatic Max-XL™ 24 x 60 with Impact Absorption System (Vista-Glide™)Vistamatic Grid 40 x 40 with Impact Absorption System (Vista-Glide™)

Minimum sizes:

Vistamatic Max™ 6 1/4 widthVistamatic SuperMax™ 25 width

Example:

If you are ordering a Max panel with one side operation that is 30 x 30: VS1 Max 30x 30

KEY = KEY LOCKING KNOBLIG = LIGITURE FREE KNOBKKL = KEY LOCKING KNOB AND LIGATURE FREE KNOBMAX = MAX PANELSUPERMAX = SUPERMAX PANELMAX-XL = MAX XL PANELLOGO = LOGO OR CORPORATE IDENTITY

USE GLASS NAME IF CHANGING FROM STANDARD TEMPERED GLAZINGPLEASE ADD SIZES TO CODE

EXAMPLE – IF YOU ARE TO ORDER A VS2 WITH LEAD GLASS = VS2MAXLEAD (SIZE)

VISTAMATIC® PRODUCTS

The VISTAMATIC® Glazed Secure Vision panel consist of three high quality glass panes with alternating natural sandblasted and clear bands to allow viewing when in the open position and complete privacy when closed. The outer panes are supplied in 1/4" (6mm) tempered safety glass and the inner pane is 5/32" (4mm) annealed. The panels are supplied fully assembled as an insulated unit and incorporate either a single or double sided polished chrome lever handle. Stainless steel ligature free knob or key locking mechanism is also available for use in a secure environment.

VISTAMATIC® MAX

1" LINES ENABLING UNRIVALLED SIGHT LINES AND INCORPORATING THE MINI DAMPING SYSTEM – (Patent pending no.1104905.3) FOR SIZES THAT REQUIRE IT

VISTAMATIC® SUPERMAX

ENCOMPASSES TWO WORKING MECHANISMS IN ONE UNIT FOR PANELS LARGER THAN 6.25SF

VISTAMATIC® CORNER

MANUFACTURED TO PRODUCE A CLEAN CORNER UNIT, WITH EXCEPTIONAL ALL ROUND VIEWING CAPABILITIES. THE UNIT CAN BE CONSTRUCTED WITH EITHER THE MAX OR SUPERMAX PANELS AND CAN ALSO BE SUPPLIED AT ANY ANGLE.

VISTAMATIC® VISTAPORT™

YEARS OF DEVELOPMENT PRODUCED THE VISTAPORT™ AND WE CAN OFFER THIS AS ONE SIZE ONLY 15 3/4"

VISTAMATIC® MAX-XL™

DESIGNED TO OFFER A STREAMLINE APPEARANCE TO ANY DOOR REQUIRING A FULL LENGTH PANEL

Maximum size 24 x 60

HANDLE TYPES

LEVER HANDLE KEY LOCKING KNOB LIGITURE FREE KNOB

OTHER OPTIONS

VINYL LINES – WHEN CLOSED CAN BE USED AS A LIGHT BLOCKER

LOGO & CORPORATE IDENTITIES DIFFERENT DESIGNS ON REQUEST

Installation Instructions for VISTAMATIC® Glazed Secure Vision Panel

Wood Bead Fitting

Pre-Installation Fitting Check 1. The panel is the correct size to the order placed2. When the panel is standing on the bottom edge (the handle is at the bottom) the panel functions smoothly. DO NOT

install if the handle mechanism is not functioning correctly.3. The aperture is 1/8" overall larger than the panel as it should not be a tight fit.

Installation Instructions1. Fit the hardwood fixing beads to one side of the aperture. This can be achieved by screwing or nailing whichever is

suitable for the project. Fit intumescent material if required for fire rated door.2. Offer the panel into the aperture use packing wedges to make sure that panel is sitting square in the aperture.3. Fit the hardwood fixing beads to the reverse side of the aperture as described in part 1. Fit the fixing beads top and

bottom first and check that the VISTAMATIC® Glazed Secure Vision Panel is functioning correctly and the fixing beads are not too tight. It is VERY IMPORTANT that you DO NOT pinch the panel, as this will stop the VISTAMATIC® Glazed Secure Vision Panel from functioning and cause scratching. When you are sure that all is correct fit the side fixing beads in the same way.

Hollow Metal Frame Fitting

Pre-Installation Fitting Check

1. The panel is the correct size to the order placed2. When the panel is standing on the bottom edge (the handle is at the bottom) the panel functions smoothly. DO NOT

install if the handle mechanism is not functioning correctly.3. The aperture is 1" (if HMF is purchased from Vistamatic®) overall larger than the panel as it should not be a tight fit. If using

your own framing, the VISTAMATIC® Glazed Secure Vision Panel shoule be sized as the glass size to fit.Installation Instructions

1. Fit the Hollow Metal Frame to one side of the aperture. This can be achieved by screwing or nailing whichever is suitable for the project. Fit intumescent material if required for fire rated door.

2. Fit the fixing screws top and bottom first and check that the VISTAMATIC® Glazed Secure Vision Panel is functioning correctly and the fixing beads are not too tight. It is VERY IMPORTANT that you DO NOT pinch the panel, as this will stop the VISTAMATIC® Glazed Secure Vision Panel from functioning and cause scratching. When you are sure that all is correct fit the side fixing beads in the same way.

Care and Protection of your Vistamatic® Glazed Secure Vision Panels

By following a few simple rules during usage and cleaning you can prolong the life of your Vistamatic Vision Panels and assist in retaining their good appearance.

DOClean only with mild soaps or detergents added to water, or a proprietary non abrasive glass cleaner.Clean using soft or synthetic window leather.Use a squeegee or soft cloth for drying the window.

DO NOTUse brushes or sharp edge items at any time on the Vistamatic Vision Panels.

If in doubt please contact Vistamatic LLC about further guidance in respect of cleaning

Terms and Conditions

1. The warranty applies to the user of the product and is not transferable.2. The warranty applies to an original installation and does not cover previously installed products. 3. The warranty applies only to manufacturing or material defects and does not apply to normal wear and tear, inappropriate

use or accidental damage after delivery. Applicable for a 1 year period.4. The warranty applies only if products have been installed according to our instructions and maintained according to our

recommendations. 5. The warranty applies only to the product itself. 6. The warranty is only valid for products installed in the United States of America7. If a product is found to be of faulty manufacture VISTAMATIC® reserve the right to either replace or repair the product

and excludes any claim for consequential loss or damage. 8. Should you have a claim against this guarantee you should contact VISTAMATIC® warranty department within 21 days of

the fault occurring. 9. VISTAMATIC® reserves the right to charge for engineer’s time and replacement parts if a claim is not due to faulty

manufacture or components. 10. No claim will be accepted if a product is installed with a fault that would have been clearly visible before installation. The

warranty does not cover equipment which has been damaged due to misuse, abuse, or accident.

*Lifetime Warranty / against faulty handle mechanism:If a defect in the working handle mechanism in your VISTAMATIC® glazed secure vision panel, Vistamatic LLC will provide, at your choice, either free replacement or repair of your product within 28 working days of the reported fault and return of faulty panel.

All and any carriage or freight charges at the registered owners cost.

Care and Protection of your VISTAMATIC® glazed secure vision panels.

By following a few simple rules during usage and cleaning you can prolong the life of your Vistamatic® vision panels and assist in retaining their good appearance.

DOClean only with mild soaps or detergents added to water or a proprietary non abrasive glass cleaner.Clean using soft or synthetic window leather.Use a squeegee or soft cloth for drying the window.

DO NOTUse brushes or sharp edge items at any time on Vistamatic® vision panels.Do not attempt to use any type of lubricant on operating mechanism.

If in doubt please contact Vistamatic LLC.

*Any alteration to original specification will negate the Warranty.

To correctly specify VISTAMATIC® products, in design details, working drawings, specifications and Bills of Quantities.

VISTAMATIC® is a registered Trade Mark in the United Kingdom and the European Union at large.

VISTAMATIC® products include:

• VISTAMATIC® - Glazed Secure Vision Panels

• VISTAMATIC™ Max - Glazed Secure Vision Panels

• VISTAPORT® - Glazed Secure Vision Panels

When specifying products from the VISTAMATIC® range, please observe the following guidelines in order to comply with the statutory regulations

governing the use of a Trade Mark registered in the United Kingdom and the European Union at large.

1. VISTAMATIC® should be distinguished as a brand from the surrounding text, by the use of capital letters.

2. The ® or ™ symbol should be used in the first instance after the word VISTAMATIC in every occurance it is used in any given piece of literature,

article or other text. This symbol lets consumers know that VISTAMATIC® is a registered trade mark.

3. VISTAMATIC® is not a 'generic' name or term for a secure vision panel, but is the brand name for a range of specific secure vision panels by the

UK manufacturer VISTAMATIC® Limited.

4. The VISTAMATIC® name should never be used in association or conjunction with any competitor or manufacturer of similar products. Doing so

may damage the goodwill and reputation of the VISTAMATIC® brand and range of products, as well as diluting the registered rights in the mark.

This will result in the misrepresentation of the VISTAMATIC® trade mark.

5. It should be acknowledged in any piece of literature, article, specification or other text featuring the mark, that VISTAMATIC® is a registered

trade mark of Vistamatic Limited.

6. VISTAMATIC® should not be used in any sense which suggests that it is a generic term and not a trade mark of Vistamatic Limited. The trade

mark should not be used as a noun or verb. For example, one should always refer to VISTAMATIC® vision panels and not VISTAMATICS.

7. VISTAMATIC® should not be used to describe the products of parties other than Vistamatic LLC. In particular, wording of the type “this is a

Vistamatic type vision panel” must not be used.

SECTION 08880

SWITCHABLE PRIVACY GLASS VISION PANELS

Display hidden notes to specifier. (Don't know how? Click Here)

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Switchable Privacy Glass Vision Panels.

1.2 RELATED SECTIONS

A. Section 07900 - Joint Sealers.

B. Section 08110 – Steel Doors and Frames.

C. Section 08210 – Wood Doors and Frames.

1.3 REFERENCES

A. ASTM C 1036 - Standard Specification for Flat Glass.

B. ASTM C 1048 - Standard Specification for Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass.

C. ANSI Z97.1-2004 Glazing Materials Used in Buildings-Safety performance Specifications and Methods of Test.

D. Consumer Product Safety Standard (CPSC) 16 CFR 1201: Safety Standard for Architectural Glazing Materials.

1.4 SYSTEM DESCRIPTION

A. Switchable Privacy Glass Vision Panels: Vistamatic Vision Panels are a unique patented dual-position safety vision panel used where there is a need for privacy coupled with the opportunity for observation without disturbance.

1.5 SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data sheets on each product to be used, including:1. Preparation instructions and recommendations.2. Storage and handling requirements and recommendations.3. Installation methods.

C. Shop Drawings: Dimensioned drawings of glazing assemblies indicating the following:1. Elevations; include joint locations, transitions, and terminations.2. Construction details; include fabrication details of joints, transitions and terminations.3. Anchoring details; indicate construction activities and materials required that are not provided by glazing

assemblies installer.

D. Manufacturer's Certificates: Certify products meet or exceed specified requirements.

E. Closeout Submittals: Provide manufacturer’s maintenance instructions that include recommendations for periodic checking and adjustment of cable tension and periodic cleaning and maintenance of all railing and infill components.

1.6 QUALITY ASSURANCE

A. Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten years experience.

B. Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of three years demonstrated experience in installing products of the same type and scope as specified.

C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.1. Finish areas designated by Architect.2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.3. Refinish mock-up area as required to produce acceptable work.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer's unopened packaging until ready for installation.

B. Provide temporary label on each light of glass identifying manufacturer, glass type, quality and nominal thickness.

C. Store in accordance with manufacturer’s printed instructions on case. Store in areas least subject to traffic or falling objects. Keep storage area clean and dry.

D. Unpack cases following printed instructions on case. Stack individual panels on edge leaned slightly against upright supports with separators between each.

1.8 SEQUENCING

A. Ensure that products of this section are furnished to affected trades in time to prevent interruption of construction progress.

1.9 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.10 WARRANTY

A. Lifetime warranty, against handle mechanism failure due to faulty workmanship.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Vistamatic LLC; 5645 Coral Ridge Dr., Suite 279, Coral Springs, FL 33076. ASD. Tel. Toll Free (866) 466-9525. Fax: (866) 861-9135. Email: [email protected]. Web Site: www.vistamatic.com.

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2 MATERIALS

A. Switchable Privacy Glass Vision Panels: Provide Vistamatic Vision Panels in locations indicated on the Drawings or as listed on the Schedule at the end of this Section. 1. Panel Types:

a. VS1 Max: Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines.b. VS2 Max: Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines.c. VS1 SuperMax: Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines.d. VS2 SuperMax: Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines.e. VW1 Max: Vistamatic Glazed Secure Vision panel with one side handle, White Vinyl Lines (Blackout).f. VW2 Max: Vistamatic Glazed Secure Vision panel with two side handle, White Vinyl Lines (Blackout).g. VW1 SuperMax: Vistamatic Glazed Secure Vision panel with one side handle, White Vinyl Lines

(Blackout).h. VW2 SuperMax: Vistamatic Glazed Secure Vision panel with two side handle, White Vinyl Lines

(Blackout).i. VB1 Max: Vistamatic Glazed Secure Vision panel with one side handle, Black Vinyl Lines (Blackout).j. VB2 Max: Vistamatic Glazed Secure Vision panel with two side handle, Black Vinyl Lines (Blackout)k. VB1 SuperMax: Vistamatic G.lazed Secure Vision panel with one side handle, Black Vinyl Lines

(Blackout).l. VB2 SuperMax: Vistamatic Glazed Secure Vision panel with two side handle, Black Vinyl Lines (Blackout).m. VG1 Max: Vistamatic Glazed Secure Vision panel with one side handle, Grid Sandblasted Pattern.n. VG2 Max: Vistamatic Glazed Secure Vision panel with two side handle, Grid Sandblasted Pattern.o. Max XL1: Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines, bottom 1/2

solid sandblast.p. Max XL2: Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines, bottom 1/2

solid sandblast.q. Vistaport1: Vistamatic Glazed Secure Vision panel with one side handle, sandblasted lines.r. Vistaport2: Vistamatic Glazed Secure Vision panel with two side handle, sandblasted lines.s. Slide1: Vistamatic Glazed Secure Window with one side handle, sandblasted Vertical lines.t. Slide2: Vistamatic Glazed Secure Window with two side handle, sandblasted Vertical lines.

2. Size: Panels are all-in-one triple glazed panels. Each standard unit shall be 11/16 inch (17.46 mm) thick and shall fit into standard thickness doors. Standard panel incorporates two 1/4 inch (6 mm) tempered glass on the outer panes. a. Rectangle:

1) Vistamatic Max with VistaGlide Impact Absorption System is available in a maximum size of 40 inches (1016 mm) by 40 inches (1016 mm) and a minimum width of 6-1/4 inches (158.75 mm) wide.

2) Vistamatic SuperMax with VistaGlide Impact Absorption System is available in a maximum size of 48 inches (1219 mm) by 48 inches (1219 mm) and a minimum width of 25 inches (635 mm) wide.

3) Vistamatic Vista-Slide 60 inches (1524 mm) by 40 inches (1016 mm).4) Vistamatic Max-XL with VistaGlide Impact Absorption System is available in a maximum size of 24

inches (610 mm) by 60 inches (1524 mm).5) Vistamatic Grid with VistaGlide Impact Absorption System is available in a maximum size of 40

inches (1016 mm) by 40 inches (1016 mm).b. Round:

1) Vistamatic Vistaport 15-3/4 inches (400 mm).3. Opacity/Glass Patterns:

a. Natural sandblasted lines.b. Black screened bands. c. White screened bands.d. Custom pattern as selected by the Architect.

4. Glass types: a. Heat-Treated Float Glass: ASTM C 1048; Type I (transparent flat glass). b. Safety Glass:

1) 3/8 inch (10 mm) tempered glass. 2) 3/4 inch (19 mm) tempered glass.3) 1/4 inch (6 mm) tempered glass. 4) 1/2 inch (12 mm) tempered glass.5) Bullet Resistant 3/4 inch (19 mm) laminated glass.

c. Fire Safety Glass: 1) Firelite NT 3/16 inch (5 mm) Fire Resisting 20/45 minimum. 2) Pyroguard C730 1/4 inch (6 mm) Fire Resisting 20 min.

d. Medical Glass: 1) Med-XTM 1/16 inch (2.1 mm) Lead glass. 2) Med-XTM 1/16 inch (2.4 mm) Lead glass. 3) Med-XTM 1/8 inch (2.9 mm) Lead glass. 4) Laser Polymer.

e. Films: 1) 3M Scotchshield Ultra Safety and Security Window Film.

B. Special Features:1. Key locking knob 2. Key locking knob and ligature free knob 3. Fire Resistance; 20 minute and 45 minute with hose stream test UL 10B/C 4. X-Ray protection5. Laser protection 6. Pictogram/Logo available7. High security available.

2.3 FABRICATION

A. Fabricate glazing units in sizes required to glaze openings indicated for Project, with edge and face clearances, edge and surface conditions, and bite complying with written instructions of product manufacturer and referenced glazing publications, to comply with system performance requirements.

PART 3 EXECUTION

3.1 EXAMINATION

A. Do not begin installation until openings have been properly prepared.

1. Examine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation.

2. Verify that openings conform to details; dimensions and tolerances indicated on the approved shop drawings.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

A. Install in accordance with manufacturer's instructions.

B. Set glazing without bending, twisting, or forcing of units.

C. Do not allow glass to rest on or contact any framing member.

D. Patterned Glass: Install units in interior partitions with pattern in same direction in all openings.

E. Insulating Glass Units: 1. Glaze in compliance with glass manufacturer's written instructions. 2. When glazing gaskets are used, they shall be of sufficient size and depth to cover glass seal or metal channel

frame completely. 3. Do not use putty or glazing compounds. 4. Do not grind, nip, cut, or otherwise alter edges and corners of fused glass units after shipping from factory. 5. Install with tape or gunnable sealant in wood sash.

F. Fire Resistant Glass: Other fire resistant glass: Glaze in accordance with UL design requirements.

G. Bullet Resisting Material: Glaze as recommended by manufacturer, using glazing material which will permit expansion and contraction of the bullet resistive material in the frame.

3.4 REPLACEMENT AND CLEANING

A. Clean glass surfaces removing temporary labels, paint spots, and defacement after approval by Resident Architect.

B. Replace cracked, broken, and imperfect glass, or glass which has been installed improperly.

3.5 PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

3.6 SCHEDULES

A. :1.2.3.

B. :1.2.3.

END OF SECTION

TO GET A COPY OF OUR SPEC’S, BIM OR CAD DRAWINGS GO TO AND SEARCH FOR VISTAMATIC® OR TYPE THIS LINK IN TO YOUR BROWSER