ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new...

19
ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is based on the position smearing in the 3 directions: X,Y,Z of the 2 end points of the microtrack. In such a way the basetrack smearing of the slopes is obtained for free. In addiction, with this technique, the smearing ellipse in the Tx:Ty plane has main axes in the longitudinal and transversal direction, as seen in the data.

Transcript of ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new...

Page 1: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

ORFEOv6r3

10. GeV muons

This data MC comparison was made with the last version of ORFEO.Here a new version of the smearing tool is implemented, this is based on the position smearing in the 3 directions: X,Y,Z of the 2 end points of the microtrack. In such a way the basetrack smearing of the slopes is obtained for free. In addiction, with this technique, the smearing ellipse in the Tx:Ty plane has main axes in the longitudinal and transversal direction, as seen in the data.

Page 2: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Efficienze dal brick vuoto

esposto ai cosmiciEfficienza ufficiali

Eff lead MC pions Eff no lead MC pions

Page 3: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Electrons 6 GeV

• The events were generated with OpRoot

• The smearing parameters are: Sx=0.4 micron, Sy=0.25 micron, Sz=2.5 micron. (these value were obtained with a tooning on the data)

Page 4: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

TRIGGER dataMC

Page 5: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Slopes resolution(Tmicro-Tbase)

MC data

Page 6: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

eCHI2P vs PHThis is the results of the micro slopes resolution

simulation (eCHI2P) and of the micro pulse height parametrization (bt PH)

DatiMC

bg rejected

Page 7: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Bt angle resolutionBin(i-1)=T(i)-T(1), i>1

MC Dati

Page 8: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Base Pulse and eCHI2P DatiMC

Page 9: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Number of segments followed without propagation (strongly related to micro track efficiencies)

Dati

MC without Efficiencies micro track

rejection

Eff. As measured inEmpty brick

(only cosmics exposition)

MC+eff.

Page 10: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

MC: no correlation betweenMicro tracks momentum and pulse height by construction

Data

Page 11: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Pions 4 GeV

• The events were generated with OpRoot

• The smearing parameters are: Sx=0.25 micron, Sy=0.25 micron, Sz=2.5 micron. (these value are the same used for all the “official” productions)

Page 12: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

TRIGGER dataMC

Page 13: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Slopes resolution(Tmicro-Tbase)

MC data

Page 14: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

eCHI2P vs PHThis is the results of the micro slopes resolution

simulation (eCHI2P) and of the micro pulse height parametrization (bt PH)

DatiMC

bg rejected

Page 15: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Bt angle resolutionBin(i-1)=T(i)-T(1), i>1

MC Dati

Page 16: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Base Pulse and eCHI2P DatiMC

Page 17: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Number of segments followed without propagation (strongly related to micro track efficiencies)

Dati

MC+eff.Assuming eff.=84.%

(84.% at theta<0.1mrad measured data)

Page 18: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

MC: no correlation betweenMicro tracks momentum and pulse height by construction

Data

Page 19: ORFEOv6r3 10. GeV muons This data MC comparison was made with the last version of ORFEO. Here a new version of the smearing tool is implemented, this is.

Transversal and longitudinal resolution for simulated 10.GeV pions at 0.7 mrad