Oil Pumps - Boiler Parts - Boilerparts.co.ke

38
Oil pump PO Oil pump PO Oil pump and accessories SUNTEC ................................ CSB.160 DANFOSS.............................. CSB.172 DELTA ................................... CSB.178 ECKERLE .............................. CSB.179 RIELLO ................................. CSB.181 SAFAG .................................. CSB.182 SP ........................................ CSB.183 Solenoid valve ...................... CSB.183 Transfer pump ...................... CSB.185 Suctionpump ........................ CSB.190 Carburettor .......................... CSB.194 CSB SUNTEC pump Solenoid valve Transfer pump GPS-10 oil suction transfer unit Carburettor

description

Oil Pumps available at Boiler Parts, Kenya. boilerparts.co.keOil pumps available from the following manufacturers:SUNTEC - CSB.160DANFOSS - CSB.172DELTA - CSB.178ECKERLE - CSB.179RIELLO - CSB.181SAFAG - CSB.182SP - CSB.183Solenoid - valve - CSB.183Transfer - pump - CSB.185Suctionpump - CSB.190Carburettor - CSB.194

Transcript of Oil Pumps - Boiler Parts - Boilerparts.co.ke

Page 1: Oil Pumps - Boiler Parts - Boilerparts.co.ke

Oil pumpPO

Oil p

ump

PO

Oil pump and accessories

SUNTEC ................................ CSB.160

DANFOSS .............................. CSB.172

DELTA ................................... CSB.178

ECKERLE .............................. CSB.179

RIELLO ................................. CSB.181

SAFAG .................................. CSB.182

SP ........................................ CSB.183

Solenoid valve ...................... CSB.183

Transfer pump ...................... CSB.185

Suctionpump ........................ CSB.190

Carburettor .......................... CSB.194

CSB

SUNTEC pump

Solenoid valve

Transfer pump GPS-10 oil suction

transfer unit

Carburettor

Page 2: Oil Pumps - Boiler Parts - Boilerparts.co.ke

YOU SEARCH A PUMP You must know :

•Burner mark •Burner type•Burner number •Burner manufacturing year

But many burner manufacturers use different pumps on the same burner.So you can note :The engraved pump reference

But if it is not possible to read this information you must note :

•Ø of shaft •shaft rotation (with shaft in front of you) •Ø of hub •outlet nozzle side (with shaft in front of you) •with fl ange •with solenoid valve •or without fl ange •or without solenoid valve •nozzle capacity

DISTRIBUTED BY DIFF

SUNTEC AU 47 revision 6P

Description RefSUNTEC Suitcase with 2 AU 47 pumps 301992

Contains 2 AU pumps and accessories, allows to repair the majority of burner oil pump or kerosene pump with or without solenoid valve, with right or left rotation, with right or left outlet nozzle position, with or without flange can be repaired.

Type Flow l/h to 2800 tr/mn and 10 bars

M=Hub Ø=Shaft Rotation Outlet

nozzle sidePressure

bar Ref

AU 47 L 9853 6P0500 40 M 32 x Ø8 � 4/25 301870AU 47 R 9852 6P0500 40 M 32 x Ø8 � � 4/25 301871

In this suitcase you have also spare parts and accessories for maintenance. Suitcase components : �1 AU 47 L pump (left rotation, left or right outlet nozzle position). Diff ref 301870 �1 AU 47 R pump (right rotation, left or right outlet nozzle position). Diff ref 301871 �2 connectors Diff ref 803030 �2 strainers Diff ref 301561 �1 coil 220-240V, 50/60 Hz Diff ref 301478 �2 cover gaskets Diff ref 301434 �1 changing kit AU pump to AE pump Diff ref 301589 �1 adapter hub Ø32 / 54 Diff ref 301310 �1 flange allows to obtain a pump with fixing flange and hub Ø54 Diff ref 301301 �1 TE FEM 1/8-1/8 Diff (from connection) ref 602510 �1 Extension shaft pupm DN8/11,1 Diff ref 601130

Universal replacement pump2 pumps replace 51 Suntec models

24 Delta Fuel Master modelsand 105 Danfoss models

Suntec proposes a new pump specially designed for maintenance market : The AU 47 revision 6 pump

Technical features : � Better stock control � Quick and easy installation � Outlet nozzle on the right or on the left � Normally closed solenoid valve � Same performance and quality as SUNTEC type “A“

AU revision 6 pumps replace more pumps than AU revision 2.The photographic model is an «AU 47L» (left rotation - Outlet nozzle on the right or on the left, in front of the shaft) So, the suitcase with 2 AU47 pumps (left and right rotation), 1 adaptor hub, 1 flange and 1 changing AU to AE pump kit can replace 95% of low flow pumps.

AU 47 R 9852 6P 0500 Pump Diff ref 301871 AU 47 L 9851 6P 0500 Pump Diff ref 301870

IMPORTANT Note : The new AU 47 revision 6 pump allows a direct sealing at the bottom of the inlet and return ports.It is not possible with AU 47 revision 2.

All these accessories arealso separately sold for thesuitcase restocking

Oil pump

CSB.160

Oil p

ump

PO

Page 3: Oil Pumps - Boiler Parts - Boilerparts.co.ke

A2L Range with 2 SOLENOID VALVES

The SUNTEC A2L oil pump has two nozzle outlets. It incorporates two blocking solenoid valves with in-line cut-off function, one for each nozzle outlet. Application : � Domestic Fuel oil � 2 nozzle outlets � 2 blocking solenoid valves with in-line cut-off function � 1 regulator for both nozzle lines

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

A2L 65 A 9708 2P 0500 82* M32x8 - � � 8/15 301892A2L 65 B 9707 2P 0500 82* M32x8 - � � 8/15 301893A2L 65 C 9704 2P 0500 82* M32x8 (1) � 7/14 301894A2L 65 D 9703 2P 0500 82* M32x8 (2) � 8/15 301930A2L 75 C 9701 2P 0500 110* M32x8 (1) � 7/14 301895A2L 95 B 9711 2P 0500 132* M32x8 - � � 9/25 301896A2L 95 D 9702 2P 0500 132* M32x8 (2) � 8/15 301931

(1) Kerosene - (2) Inlet and Return M16 - * With air jack outlet

AL Range with SOLENOID VALVEThe SUNTEC AL oil pump incorporates a blocking solenoid valve with in-line cut-off function. Bleeding in two-pipe operation is auto-matic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system..Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AL 30 C 9537 4P 0500 40 M 32 x 8 - 8/15 301946AL 35 A 9526 2P 0500 40 M 32 x 8 - � � 8/15 301949AL 35 A 9570 2P 0500 40* M 32 x 8 - � � 8/15 301958AL 35 A 9596 2P 0100 40* M 32 x 8 (5) � � 8/15 301936AL 35 A 9596 2P 0500 40* M 32 x 8 - � � 8/15 301869AL 35 B 9580 2P 0500 40* M 32 x 8 - � 8/15 301956AL 35 C 9521 2P 0100 40 M 32 x 8 (5) 4/18 301938AL 35 C 9521 2P 0500 or AL 35C 9519 6P 0500 40 M 32 x 8 - 4/18 301873AL 35 C 9528 2P 0500 40 M 32 x 8 - 8/15 301957AL 35 C 9540 2P 0500 40 M 32 x 8 (1) 8/15 301950AL 35 C 9545 1P 0500R 40 M 32 x 8 (1) 8/15 see 301950AL 35 C 9578 2P 0500R 40* M 32 x 8 - 8/15 see 301987AL 35 D 9529 2P 0200 40 M 32 x 8 (2) � 8/15 301959AL 35 D 9529 2P 0500 40 M 32 x 8 - � 8/15 301939AL 35 D 9595 2P 0500 40 M 32 x 8 (6) � 8/15 see 301939AL 55 C 9598 2P 0500 60 M 32 x 8 (4)(6) 10/25 see 301986AL 65 B 9532 2P 0500 82 M 32 x 8 - � 4/18 301877AL 65 C 9410 2P 0500 82* B 54 x 8 - 4/18 301879AL 65 C 9525 2P 0500 82 M 32 x 8 (3) 8/15 301980AL 65 C 9588 2P 0500 82* M 32 x 8 - 8/15 301981AL 65 C 9589 2P 0500 82 M 32 x 8 - 8/15 301982AL 75 B 9539 2P 0500 110 M 32 x 8 - � 8/15 301880AL 75 C 9411 2P 0500 110* B 54 x 8 - 4/18 301881AL 95 C 9412 2P 0500 132* B 54 x 8 - 10/20 301984AL 95 C 9414 2P 0500 132* B 54 x 8 (7) 10/20 301882AL 65 C 9525 2P 0500 82 M 32 x 8 (5) 8/15 301980AL 65 C 9588 2P 0500 82* M 32 x 8 - 8/15 301981AL 65 C 9589 2P 0500 82 M 32 x 8 - 8/15 301982AL 75 B 9539 2P 0500 110 M 32 x 8 - � 8/15 301880AL 75 C 9411 2P 0500 110* B 54 x 8 - 4/18 301881AL 75 C 9534 2P 0500 110 M 32 x 8 (5)(6) 8/15 301983AL 95 C 9412 2P 0500 132* B 54 x 8 - 10/20 301984AL 95 C 9414 2P 0500 132* B 54 x 8 (10) 10/20 301882

(1) Inlet and Return.1/8" - (2) Coil 24 VAC - (3) Conical nipple Ø4 - (4) Kerosene - (5) Coil 110VAC - (6) Adjusting screw pressure on the nozzle side. (7) Shaft with 2 flat surfaces * With outlet air jack.

ALE Range with SOLENOID VALVEThe SUNTEC ALE oil pump incorporates a blocking solenoid valve fitted with a built-in return valve ensuring an in-line cut-off function and a nozzle line pressure relief. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system. Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

ALE 35 A 9325 2P 0500 40 M 32 x 8 - � � 8/15 301883ALE 35 C 9322 2P 0500 40 M 32 x 8 - 10/25 301886ALE 35 C 9324 2P 0500 40 M 32 x 8 - 4/18 301888ALE 35 C 9327 2P 0500 40* M 32 x 8 - 8/15 301889ALE 35 C 9328 2P 0500 40* M 32 x 8 (1) 8/15 301890ALE 35 C 9329 6P 0500 40 M 32 x 8 (2)(3) 12/25 301985ALE 35 C 9334 2P 0500* 40 M 32 x 8 (4) 8/15 301987ALE 55 C 9330 2P 0500 58 M 32 x 8 (2)(3) 12/25 301986

(1) Kerosene - (2) Adjusting pressure screw on the nozzle side - (3) Shaft with 2 flat surfaces (4) Direct sealing Inlet and Return * With outlet air jack

Oil pump

CSB.161

Oil p

ump

PO

Page 4: Oil Pumps - Boiler Parts - Boilerparts.co.ke

AR Range with SOLENOID VALVEThe SUNTEC AR oil pump incorporates a blocking solenoid valve with in-line cut-off function and a second regulator for nozzle return pipe. Bleeding in two pipe operation is automatic. In one-pipe operation, the plug of a pressure gauge port must be loosened until the air is evacuated from the system

Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AR 65 A9801 2P 0500 75 M 32 x 8 � � 12/25 5/15 301897

AN Range without SOLENOID VALVEThe SUNTEC AN oil pump is the basic model incoporating pressure regulation valve with cut-off.

Information ANThe pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AN 47 A 7216 3P 40 B 54 x 8 (2)(4) � � 7/14 301041AN 47 A 7283 2M 40 B 54 x 8 (1)(3)(4) � � 7/14 see 301041AN 47 B 7217 3P 40* B 54 x 8 (2)(4) � 7/14 301732AN 47 C 7218 3P 40 B 54 x 8 (2)(4) 7/14 301734AN 47 D 7219 3P 40 B 54 x 8 (2)(4) � 7/14 301047AN 47 A 1326 1P 40 M 32 x 8 - � � 7/14 301731AN 47 A 7326 3P 40* M 32 x 8 - � � 7/14 301733AN 47 A 7226 3P 40 M 54 x 8 (2) � � 7/14 301042AN 47 B 1395 1P 40 M 32 x 8 - � 7/14 301049AN 47 B 7227 3P 40* M 54 x 8 (2) � 7/14 301043AN 47 B 7327 3P 40* M 32 x 8 - � 7/14 301044AN 47 C 1342 1P 40 M 32 x 8 - 7/14 301750AN 47 C 7228 3P 40 M 54 x 8 (2) 7/14 301045AN 47 C 7247 3M 40* B 54 x 8 (1)(6)(4) 7/12 301737AN 47 C 7328 3P 40* M 32 x 8 (4) 7/14 301738AN 47 C 7342 3P 40* M 32 x 8 - 7/14 301739AN 47 D 1339 1P 40 M 32 x 8 - � 7/14 301749AN 47 D 7229 3P 40 M 54 x 8 (2) � 7/14 301048AN 47 D 7329 3P 40 M 32 x 8 (2) � 7/14 301749AN 57 A 7351 3P 58* M 32 x 8 - � � 7/14 301742AN 57 B 1330 1P 58 M 32 x 8 - � 10/20 301054AN 57 C 7282 3P 58* B 54 x 8 (4) 7/14 301743AN 67 A 7238 3P 82* B 54 x 8 (4) � � 10/20 301071AN 67 A 7345 3P 82* M 32 x 8 (4) � � 10/20 301076AN 67 B 1335 1P 82 M 32 x 8 - � 10/20 301074AN 67 B 7251 3P 82* B 54 x 8 (4) � 10/20 301073AN 67 B 7287 3P 82* M 54 x 8 - � 10/20 301064AN 67 C 1336 1P 82 M 32 x 8 (4) 7/14 301065AN 67 C 1338 1P 82 M 32 x 8 (6)(7) 7/12 301746AN 67 C 7233 3P 82* B 54 x 8 (4) 10/20 301075AN 67 C 7242 3P 82* M 54 x 8 - 10/20 301066AN 67 D 7252 3P 82* B 54 x 8 (4) 10/20 301077AN 77 A 7255 2P 112* M 54 x 8 - � � 10/20 301904AN 77 A 7256 2P 112* B 54 x 8 - � � 10/20 301752AN 77 C 7235 2P 112* B 54 x 8 (4) 10/20 301905AN 77 C 7275 2P 112* M 54 x 8 - 10/20 301756AN 77 C 7341 2P 112* M 32 x 8 - 10/20 301906AN 97 A 7391 2P 132* M 32 x 8 - � � 10/20 301758AN 97 C 7257 2P 132* B 54 x 8 (4) 10/20 301920AN 67 D 7252 3P 82* B 54 x 8 (4) 10/20 301077AN 77 A 7255 2P 112* M 54 x 8 - � � 10/20 301904AN 77 A 7256 2P 112* B 54 x 8 - � � 10/20 301752AN 77 A 7266 2M 112* B 54 x 8 (1)(4) � � 10/15 301753AN 77 A 7295 2P 112* M 54 x 8 (9) � � 10/20 301754AN 77 A 7346 2P 112* M 54 x 8 - � � 10/20 301796AN 77 C 7235 2P 112* B 54 x 8 (4) 10/20 301905AN 77 C 7275 2P 112* M 54 x 8 - 10/20 301756AN 77 C 7341 2P 112* M 32 x 8 - 10/20 301906AN 77 D 7358 2P 112* M 32 x 8 - � 10/20 301757AN 97 A 7391 2P 132* M 32 x 8 - � � 10/20 301758AN 97 C 7257 2P 132* B 54 x 8 (4) 10/20 301920(1) One-pipe pump - (2) Replaced by AN Kit - (3) Bleeding screw 1/4NPTF on the regulator side - (4) Long outlet nozzle (5) Shaft with 2 flat surfaces - (6) Kerosene - (7) Motor speed 3450tr/min - * with air jack outlet

Oil pump

CSB.162

Oil p

ump

PO

Page 5: Oil Pumps - Boiler Parts - Boilerparts.co.ke

ASSEMBLY

tanks to the flange, a pump with a 32mm hub Ø can be transformed into a flange pump (92mm) and a 54mm hub Ø.

�Slide the flange on the hub pump with flat surface against pump surface �Screw the flange.

NOTE The flange bosses gives a hub Ø 54 mm

Types of Pumps replaced with a current pump and this flange

Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump Ref

AN 47 A 1326 301731AN 47 A 1326 301731

+ 301310 AN 47 A 7226 301042+ 301301 AN 47 A 7216 301041

AN 47 B 7327 301044AN 47 B 7327 301044

+ 301310 AN 47 B 7227 301043+ 301301 AN 47 B 7217 301732

AN 47 D 1339 301749AN 47 D 1339 301749

+ 301310 AN 47 D 7229 301048+ 301301 AN 47 D 7219 301047

AN 47 C 1342 301750

AN 47 C 1342 301750AN 47 C 1342 301750

+ 301310 AN 47 C 7228 301045+ 301301 AN 47 C 7218 301734

AE Range without SOLENOID VALVEThe SUNTEC AE oil pump is the basic model incorporating a pressure regulating valve. It does not have a cut-off features, to purge air, gas through the nozzle line.

Information AEThe AE 87 range is replaced by the AE77 range.The flange 301301 and the adapter hub 301310 can be used with this range of AE pump

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Featu-res Rotation Outlet

nozzle side Pressure Ref

AE 35 C 9850 2P 40 M 32 x 8 (1) 4/18 301759AE 45 C 1360 1P 40 M 32 x 8 - 7/14 301801AE 45 C 1370 1M 40 M 32 x 8 (2)(4) 7/14 301802AE 47 A 1384 1M 40 M 32 x 8 (4) � � 7/14 301800AE 47 A 1384 1P 40 M 32 x 8 - � � 7/14 301761AE 47 A 7384 3M 40* M 32 x 8 (4) � � 7/14 301762AE 47 B 1366 1P 40 M 32 x 8 - � 7/14 301805AE 47 B 7267 3P 40* M 54 x 8 - � 7/14 301763AE 47 C 1386 1P 40 M 32 x 8 - 2/12 301803AE 47 C 1387 1P 40 M 32 x 8 - 7/14 301799AE 47 C 1394 1P 40 M 32 x 8 (5) 3/15 301764AE 47 C 1397 1P 40 M 32 x 8 - 10/20 see 301799AE 47 C 7368 3P 40* M 32 x 8 - 5/12 301804AE 47 C 1393 1M 40 M 32 x 8 (4)(3) 0,5/3 301797AE 47 D 1378 1M 40 M 32 x 8 (4) � 7/14 301768AE 47 D 1385 1P 40 M 32 x 8 - � 5/20 301798AE 57 B 1364 1M 50 M 32 x 8 (4) � 10/20 301769AE 57 C 7373 3P 50* M 32 x 8 (1) 8/28 301806AE 67 C 7285 3P 80* B 54 x 8 (3) 7/14 301812AE 67 C 7361 3P 80* M 32 x 8 (1) 8/28 301810AE 67 D 7278 3P 80* B 54 x 8 - � 7/14 301811AE 77 B 7291 3P 112* M 54 x 8 - � 8/28 301774AE 77 C 7270 2P 112* B 54 x 8 (3)(1) 10/28 301832AE 97 C 7296 3P 132* B 54 x 8 (3) 8/28 301794AE 97 C 7297 3P 132* B 54 x 8 (3)(6) 7/12 301795AE 97 C 7390 2P 132* M 32 x 8 (3) 0,5/3 301839AE 97 C 7390 2M 132* M 32 x 8 (4)(3) 0,5/3 301838AE 97 D 7355 2P 132* M 32 x 8 - � 2/12 301807AE 77 C 7270 2P 112* B 54 x 8 (3)(1) 10/28 301832AE 77 C 7380 2P 112* B 32 x 8 (1) 10/20 301833AE 97 C 7296 3P 132* B 54 x 8 (3) 8/28 301794AE 97 C 7297 3P 132* B 54 x 8 (3)(6) 7/12 301795AE 97 C 7390 2P 132* M 32 x 8 (3) 0,5/3 301839AE 97 C 7390 2M 132* M 32 x 8 (4)(3) 0,5/3 301838AE 97 D 7355 2P 132* M 32 x 8 - � 2/12 301807

(1) Pressure gauge port on the top - (2) Inlet 1/8" fem. Return 1/8" male - (3) Long outlet nozzle - (4) One-pipe pump(5) Shaft with 2 flat surfaces - (6) Kerosene - * with air jack outlet

Oil pump

CSB.163

Oil p

ump

PO

Page 6: Oil Pumps - Boiler Parts - Boilerparts.co.ke

AS Range with SOLENOID VALVEThe SUNTEC AS oil pump has a built in solenoid valve which controls the regulator cut-off valve giving fast cut-off and cut-on func-tion independent of the rotational speed.

Information ASThe pumps in grey line can be used for the other pump replacements with adding flange or adapter hub. In this way you can decrease your stock and increase your possibilities of repair and maintenance.Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AS 47 A 1536 1P 0500 40 M 32 x 8 - � � 7/14 301082AS 47 A 1536 6P 0500 40 M 32 x 8 (11) � � 7/14 301925AS 47 A 1564 1P 0500 40 M 32 x 8 (4) � � 7/12 301808AS 47 A 1588 1P 0500 40 M 32 x 8 (4)(10) � � 7/12 see 301815

AS 47 A 1590 1P 0200 40 M 32 x 8 (11) � � 7/14 301814AS 47 A 1602 6P 0500 40 M 32 x 8 (4)(10) � � 7/12 301815AS 47 A 7432 3P 0500 40 B 54 x 8 (5)(2)(8) � � 7/14 301081AS 47 A 7436 3P 0500 40* M 54 x 8 - � � 7/14 301816

AS 47 A 7465 2M 0500 40* B 54 x 8 (2)(4)(8)(13) � � 7/12 301818

AS 47 A 7536 3P 0500 40* M 32 x 8 - � � 7/14 301819AS 47 A 7564 3P 0500 40* M 32 x 8 (4) � � 7/12 301850AS 47 A 7509 3P 0500 40* M 32 x 8 (1)(7)(8) � 7/16 301852AS 47 B 1537 6P 0500 40 M 32 x 8 - � 7/14 301084AS 47 B 1537 1P 0260 40 M 32 x 8 (11) � 7/14 301928AS 47 B 1537 1P 0310 40 M 32 x 8 (15) � 7/14 301929AS 47 B 1605 1P 0500 40 M 32 x 8 (10) � 7/14 301822AS 47 C 1538 6P 0500 40 M 32 x 8 - 7/14 301086AS 47 C 1538 (110V) 40 M 32 x 8 (3) 7/14 301090AS 47 C 1538 1P 0200 40 M 32 x 8 (11) 7/14 301932AS 47 C 1554 1P 0500 40 M 32 x 8 (4)(9) 7/12 301846AS 47 C 1569 1P 0500 40 M 32 x 8 - 7/14 see 301086

AS 47 C 1578 1P 0500 40 M 32 x 8 - 7/25 see 301829

AS 47 C 1581 1P 0500 40 M 32 x 8 (4) 7/12 see 301846

AS 47 C 1582 1P 0500 40 M 32 x 8 (4)(14) 7/12 301826AS 47 C 1587 1P 0500 40 M 32 x 8 (4)(1) 7/25 301827AS 47 C 1601 1P 0500 40 M 32 x 8 - 7/14 see 301086

AS 47 C 1603 3P 0500 40 M 32 x 8 - 7/14 see 301086

AS 47 C 1604 6P 0500 40 M 32 x 8 (10) 7/25 301829AS 47 C 1607 1P 0500 40 M 32 x 8 (9)(10) 7/12 see 301846

AS 47 C 7434 3P 0500 40 B 54 x 8 (5)(2)(8) 7/14 301841

AS 47 C 7434 3P 0260 40* B 54 x 8 (11)(2)(8) 7/14 301933

AS 47 C 7438 3P 0500 40 M 54 x 8 (6) 7/14 301843AS 47 C 7444 3P 0500 40 B 54 x 8 (5)(2) 7/14 301085

AS 47 C 7451 3M 0500 40* B 54 x 8 (2)(4)(8)(12) 7/12 301848

AS 47 C 7461 3P 0500 40* B 54 x 8 (2)(8) 10/20 301845AS 47 C 1538 6P 0500 40 M 32 x 8 - 7/14 301086AS 47 C 7554 3P 0500 40* M 32 x 8 (4) 7/12 see 301846

AS 47 D 1539 1P 0500 40 M 32 x 8 - � 7/14 301088AS 47 D 1550 1P 0500 40 M 32 x 8 - � 7/25 301083AS 47 D 1557 1P 0500 40 M 32 x 8 (1) � 7/22 301849AS 47 D 1562 1P 0500 40 M 32 x 8 (4) � 7/12 301836AS 47 D 1586 1P 0500 40 M 32 x 8 (1)(4) � 7/25 301840AS 47 D 1596 1P 0500 40 M 32 x 8 - � - 301079AS 47 D 1596 + vis 40 M 32 x 8 - � - 406021AS 47 D 1597 1M 0500 40 M 32 x 8 (4) � 7/12 301842AS 47 D 1580 1P 0500 40 M 32 x 8 (7) � 7/14 301080AS 47 D 7435 3P 0500 40 B 54 x 8 (5)(2)(8) � 7/14 301087AS 47 D 7439 3P 0500 40 M 54 x 8 (5) � 7/14 301844

Oil pump

CSB.164

Oil p

ump

PO

Page 7: Oil Pumps - Boiler Parts - Boilerparts.co.ke

AS Range with SOLENOID VALVE (continuation)

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AS 57 A 7591 3P 0500 40* M 32 x 8 - � � 7/14 301855AS 57 B 1585 1P 0500 40 M 32 x 8 - � 7/14 301856AS 57 C 1544 1P 0500 58 M 32 x 8 - 7/14 301091AS 57 C 1583 1P 0500 58 M 32 x 8 (5) 7/12 301858AS 57 C 7441 3P 0500 58 B 54 x 8 (6)(3)(9) 7/14 301093AS 67 A 7463 3P 0500 82* B 54 x 8 (3) � � 10/15 301865AS 67 A 7466 3P 0500 82* B 54 x 8 (3)(9) � � 10/15 301866AS 67 B 1575 1P 0500 82 M 32 x 8 - � 10/15 301863AS 67 B 7449 3P 0500 82* B 54 x 8 (3)(9) � 10/15 301868AS 67 C 1570 1P 0500 82 M 32 x 8 - 10/15 301862AS 67 C 7446 3P 0500 82* M 54 x 8 (5) 10/14 301860AS 67 C 7456 3P 0500 82* B 54 x 8 (3)(9) 10/15 301861(1) Shaft with 2 flat surfaces(2) Type with flange - (3) 110 VAC - (4) Kerosene type- (5) Replaced by AS kit - (6) Outlet nozzle with flare nipple(7) Inlet and return 1/8 - (8) Long outlet nozzle - (9) Adjusting pressure screw 4mm BTR - (10) Direct sealing inlet and return(11) 24 VAC - (13) Inlet 1/4NPTF on the regulator side - (12) One-pipe pump - (13) Inlet steel plug(14) Pressure gauge port on the nozzle side - (15) 24 VDC - * With air jack outlet.

Changing KIT FROM AS pump to AN pumpASSEMBLYCut-off fuel oil inlet and power supply too. Disconnect the coil. �Remove the coil "A" �Remove the plate "B" �Remove the coil tube "C" �Put the kit "D" on the pump �Put the plate "B" on the pump �Start the burner and check for leaksNote : SUNTEC accepts no liability with consequences of wrong assemblyor wrong use of this kit.This kit can only be used for changing AS pump to AN pump.

Changing example : AS 47 C 7536 to AN 47 A 7326 AS 47 C 7538 to AN 47 C 7342

Current pump Ref + Adapter hub 32/54 + Flange hub 54 Replaced pump Replaced pump ref

AN 47 A 1536 301082 AN 47 A 7536 301082+ 301301 AN 47 A 7432 301081

AN 47 C 1538 301086

AN 47 C 7538 301086+ 301310 AN 47 C 7438 301843

+ 301301 AN 47 C 7434 301841+ 301301 AN 47 C 7444 301085

AT Range with 2 SOLENOID VALVESThe SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AT2 45 A 9547 2P 0500 46* M 32 x 8 (2) � � 8/25 301132AT2 45 C 9541 2P 0500 46* M 32 x 8 (2) 8/25 301120AT2 45 C 9563 2P 0500 46* M 32 x 8 (1)(2) 8/25 301122AT2 45 D 9538 4P 0500 46* M 32 x 8 - � 8/25 301005AT2 45 D 9544 2P 0500 46* M 32 x 8 (2) � 8/25 301121AT2 45 D 9555 2P 0500 46* M 32 x 8 (2) � 8/25 301121AT2 55 C 9549 2P 0500 65* M 32 x 8 (2) 8/25 301125AT2 55 C 9572 2P 0500 65* M 32 x 8 (2)(4) 8/25 301903AT2 65 A 9577 2P 0500 87* M 32 x 8 (2) � � 8/25 301126AT2 65 B 9587 2P 0500 87* M 32 x 8 (2) � 8/25 301907AT2 65 D 9582 2P 0500 87* M 32 x 8 (2)(5) � 2/15 301910

(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet

Oil pump

CSB.165

Oil p

ump

PO

Page 8: Oil Pumps - Boiler Parts - Boilerparts.co.ke

AT Range with 2 SOLENOID VALVES (continuation)The SUNTEC AT2 oil pump features a two mode pressure operation and incorporates a blocking solenoid valve with in-line cut-off function. Switching between low and high modes is ensured by a second integral solenoid valve.The SUNTEC AT3 oil pump incorporates in addition a pressure gauge on the cover for checking high pressure nozzle or pressure return in low pressure function. Delivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AT2 95 B 9592 2P 0500 132* M 32 x 8 (2) � 8/25 301775AT2 95 C 9585 2P 0500 132* M 32 x 8 (2)(3) 8/25 301777AT3 45 A 9559 2P 0500 46* M 32 x 8 (2) � � 8/25 301133AT3 45 C 9558 2P 0500 46* M 32 x 8 (2) 8/25 301135AT3 45 D 9546 2P 0500 46* M 32 x 8 (2) � 8/25 301130AT3 45 B 9575 2P 0500 46* M 32 x 8 (2) � 8/25 301134AT3 55 C 9550 2P 0500 65* M 32 x 8 (2) 8/25 301131AT3 55 D 9564 2P 0500 65* M 32 x 8 (2) � 8/25 301778

(1) Inlet and return 1/8" - Outlet nozzle with male nipple 1/8" for pipe Ø 4 - (2) Flow indication in high pressure function (3) Inlet and return M16 - (4) Proofed at 28 bars - (5) Kerosene - * With air jack outlet

AP Range with 2 MODE PRESSURE SOLENOID VALVESDelivered without connector

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

AP 47 A 1593 1P 0500 40 M 32 x 8 (1)(2)(3) � � 3/28 301100AP 47 B 7561 3P 0500 40* M 32 x 8 - � 3/28 301099AP 47 C 7460 3P 0500 40* B 54 x 8 (2)(4) 3/28 301097AP 47 C 7556 3P 0500 40* M 32 x 8 - 3/28 301098AP 57 A 7549 3P 0500 58* M 32 x 8 - � � 3/28 301095AP 57 C 7545 3P 0500 58* M 32 x 8 - 3/28 301092AP 67 C 7559 3P 0500 82* M 32 x 8 - 5/28 301109AP2 45 C 9560 1P 0500 46* M 32 x 8 - 8/25 301782AP2 45 D 9566 1P 0500 46* M 32 x 8 - � 4/25 301941AP2 65 B 9523 1P 0500 87* M 32 x 8 - � 4/25 301783AP2 95 C 9590 1P 0500 132* M 32 x 8 - 8/25 301943AP3 45 C 9510 1P 0500 46* M 32 x 8 - 4/25 301101

(1)Inlet/Return G18 - (2)Long outlet nozzle- (3)Special outlet nozzle plug - (4) Type with flange -* With air jack outlet. The SUNTEC AP oil pump has a built-in solenoid valve which provides a two-mode pressure operation. AP2 and AP3 ranges are from the same technology as AT2 x AT3 ranges, but without in-line cut-off function.

D Range without SOLENOID VALVEThe SUNTEC D oil pump is specially adapted for heavy oil. This pump incorporates a pressure regulator without in-line cut-off function. For oil flow 45 to90 l/h (2850 tr/mn - 20 cSt - 20 bars) viscosity 2 to 200 cSt.The new revision 3 of the range D incorporates an antiabrasion plate in the gear for more efficiency.

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft

Features Rotation Outlet nozzle side Pressure Ref

D 45 B 7347 3P 54 M 32 x 8 (3) � 10/28 301114D 45 B 7388 3P 54 M 32 x 8 (8) � 0,5/3 301786

D 45 C 7281 3P 54 B 54 x 8(4)(2)(5)(6)

10/28 301119

D 47 A 7383 3P 54 M 32 x 8 (7)(8) � � 7/25 301116D 47 D 7352 3P 54 M 32 x 8 (7)(11) � 10/28 301787D 57 C 7372 3P 72 M 32 x 8 (6)(9) 10/28 301111D 67 A 7276 3P 97 B 54 x 8 (2)(4)(5) � � 10/28 301117

D 67 A 7280 3P 97 M 54 x 8(1)(7)(10) � � 16/28 301118

D 67 C 7284 3P 97 B 54 x 8(1)(5)

(8) 10/28 301792

(1) Cover with hole for heater element (Type with in-line cut-off function) - (2) Cover vacuum gauge port G 1/4" on regulator side(3) Body vacuum gauge port G 1/8" on regulator side - (4) Long outlet nozzle - (5) Type with flange - (6) With air jack outlet on the top - (7) In-line cut-off function- (8) Cover vacuum gauge port G 1/8" on regulator side - (9) Cover vacuum gauge port G 1/8" on outlet nozzle side - (10) Inlet on cover (11) Inlet and return M14

Oil pump

CSB.166

Oil p

ump

PO

Page 9: Oil Pumps - Boiler Parts - Boilerparts.co.ke

J Range without SOLENOID VALVEThe SUNTEC J oil pump incorporates a pressure regulating valve with cut-off function except the J oil pump 1002. The J oil pump is adapted for heavy oil 2,8 to 200 cSt. The J oil pumps range 1000 are built with conical threads. The J oil pump range 1000 and 1001 incorporate an in-line cut-off function. The J oil pump range 1002 are built without in-line cut-off function.

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft Features Rotation Outlet

nozzle side Pressure Ref

J3 CAB 1000 3P 90 B 54 x 11,11 (3) � � 7/14 see 301011J3 CBB 1000 3P 90 B 54 x 11,11 (3) � 7/14 see 301012J3 CCB 1000 3P 90 B 54 x 11,11 (3) 7/14 see 301013J3 CDB 1000 3P 90 B 54 x 11,11 (3) � 7/14 see 301014J4 CAC 1000 5P 110 B 54 x 11,11 (3) � � 10/21 301011J4 CBC 1000 5P 110 B 54 x 11,11 (3) � 10/21 301012J4 CCC 1000 5P 110 B 54 x 11,11 (3) 10/21 301013J4 CDC 1000 5P 110 B 54 x 11,11 (3) � 10/21 301014J6 CAC 1000 5P 205 B 54 x 11,11 (1)(3) � � 10/21 301021J6 CAC 1002 5P 205 B 54 x 11,11 (1)(4)(3) � � 10/21 301917J6 CBC 1000 5P 205 B 54 x 11,11 (1)(3) � 10/21 301022J6 CCC 1000 5P 205 B 54 x 11,11 (1)(3) 10/21 301023J6 CCC 1002 5P 205 B 54 x 11,11 (1)(3)(4) 10/21 301918J6 CDC 1000 5P 205 B 54 x 11,11 (1)(3) � 10/21 301024J6 CAC 1001 5P 205 B 54 x 11,11 (1)(3) � � 10/21 301025J6 CCC 1001 5P 205 B 54 x 11,11 (1)(3) 10/21 301026J7 CAC 1001 4P 300 B 54 x 11,11 (2)(3) � � 10/21 301181J7 CCC 1001 4P 300 B 54 x 11,11 (2)(3) 10/21 301183J7 CCC 1002 4P 300 B 54 x 11,11 (2)(3)(4) 10/21 301919

(1) J6 pump replaces H6 pump - (2) J7 replaces H7 pump - (3) Type with flange - (4) Without in-line cut-of function

Note :Range 1000 = Inlet and return 1/4" - Outlet nozzle 1/8"Range 1001 = Inlet and return 1/2G - Outlet nozzle 1/4" gas.

AJ Range without SOLENOID VALVE CAN REPLACE J PUMPS The SUNTEC AJ oil pump is the basic model incorporating a pressure regulating valve with cut-off. This range has the same shaft and hub sizes as J and H pumps and can replace these types.The AJ oil pump type 1000 and 1003 incorporates an in-line cut-off function. The AJ oil pump type 1002 is built without in-line cut-off function.

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft Features Rotation Outlet

nozzle side Pressure Ref

AJ4 AC 1000 2P 110 B 54 x 11,11 (1) � � 10/20 301601AJ4 CC 1000 2P 110 B 54 x 11,11 (1) 10/20 301611AJ4 DC 1000 3P 110 B 54 x 11,11 (1) � 10/20 301613AJ4 CE 1002 2P 110 B 54 x 11,11 (1)(3) 10/30 301612AJ6 AC 1000 2P 200 B 54 x 11,11 (1) � � 10/20 301651AJ6 CC 1000 3P 200 B 54 x 11,11 (1) 10/20 301661AJ6 CC 1003 2P 200 B 54 x 8 (1)(2) 10/20 301663AJ6 CE 1002 3P 200 B 54 x 11,11 (1)(3) 10/30 301664AJ6 DC 1000 2P 200 B 54 x 11,11 (1) � 10/20 301671

(1) Type with flange - (2) Special type with shaft Ø 8 - (3) Without in-line cut-off function

E Range without SOLENOID VALVE FOR MEDIUM FUEL OILThe SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.

The SUNTEC E type 1001 incorporates an in-line cut-off function.The SUNTEC E type 1069 are built without in-line cut-off function.

Type

Flow l/h to 2800 tr/

mn and 10 bars

M=Hub B=Flange Ø=Shaft Features Rotation Outlet

nozzle side Pressure Ref

E4 NA 1001 6P 130 B 54 x 11,11 (3)(4) � � 14/30 301151E4 NA 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6) � � 14/30 301152E4 NC 1001 6P 130 B 54 x 11,11 (3)(4) 14/30 301153E4 NC 1069 6P 130 B 54 x 11,11 (3)(4)(5)(6) 14/30 301155

(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating elementNOTE : All these pumps incorporate a flange.

Oil pump

CSB.167

Oil p

ump

PO

Page 10: Oil Pumps - Boiler Parts - Boilerparts.co.ke

E Range without SOLENOID VALVE FOR MEDIUM FUEL OIL (continuation)

The SUNTEC E oil pump incorporates a pressure regulating valve with cut-off function. This range can be used with medium and light oil. The SUNTEC E oil pump type 1069 is built with a drilling to accept a heating preheater (temp. max. 120°C). With pressure regulator 14 to 30 bars.

The SUNTEC E type 1001 incorporates an in-line cut-off function.The SUNTEC E type 1069 are built without in-line cut-off function.

TypeFlow l/h to 2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft Features Rotation Outlet

nozzle side Pressure Ref

E6 NA 1001 6P 228 B 54 x 11,11 (3)(4) � � 14/30 301161E6 NA 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6) � � 14/30 301145E6 NA 1070 6P 228 B 54 x 11,11 (3)(4)(6) � � 16/28 301922E6 NB 1001 5P 228 B 54 x 11,11 (3)(4) � 14/30 301162E6 CC 1001 6P 228 B 54 x 11,11 (1)(2)(4) 14/30 301166E6 NC 1001 6P 228 B 54 x 11,11 (1)(3)(4) 14/30 301163E6 NC 1069 6P 228 B 54 x 11,11 (3)(4)(5)(6) 14/30 301165E6 ND 1001 6P 228 B 54 x 11,11 (3)(4) � 14/30 301164E7 NA 1001 5P 340 B 54 x 11,11 (3)(4) � � 14/30 301171E7 NA 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6) � � 14/30 301170E7 CC 1001 5P 340 B 54 x 11,11 (2)(4) 14/30 301174E7 NC 1001 5P 340 B 54 x 11,11 (1)(3)(4) 14/30 301173E7 NC 1069 5P 340 B 54 x 11,11 (3)(4)(5)(6) 14/30 301175

(1) Used for OERTLI E6CC and E7CC - (2) Strainer 170µm - (3) Strainer 550µm - (4) Type with flange - (5) Without in-line cut-off function - (6) Cover with hole for heating elementNOTE : All these pumps incorporate a flange.

TA Range with PRESSURE REGULATOR for LIGHT and HEAVY FUEL OILFor light and heavy fuel oil, viscosity mini 4 cSt, maxi 800 cST, temperature 140°C at 40 bars except T5 and TA5 : 30 bars.

New : Carbon oxyde deposit on the gear surface, autolubricant carbon bearing. Sintered iron crescent replaces bronze crescent for better resistance to heavy fuel oil. With pressure regulator.

TypeFlow l/h to

2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft Rotation Pressure Ref

TA2 A 4010 5 500 B 54 x 12* � 7/40 301270TA2 C 4010 5 500 B 54 x 12* 7/40 301271TA3 A 4010 5 750 B 54 x 12* � 7/40 301272TA3 C 4010 5 750 B 54 x 12* 7/40 301273TA4 A 4010 5 1000 B 54 x 12* � 7/40 301274TA4 C 4010 5 1000 B 54 x 12* 7/40 301275TA5 C 3010 5 1350 B 54 x 12* 7/30 301277

Hub Ø 54, entraxe flange : 125mm - Shaft Ø 12mm - *With flangeNOTE : This range of pump may be fitted with a preheater.

T Range without REGULATOR for LIGHT and HEAVY FUEL OIL

TypeFlow l/h to

2800 tr/mn and 10 bars

M=Hub B=Flange Ø=Shaft Rotation Pressure Ref

T2 C 105 1400 B 70 x 20 (1) Maxi 40 301251T3 A 105 2000 B 70 x 20 (1) � Maxi 40 301252T3 C 105 2000 B 70 x 20 (1) Maxi 40 301253T4 A 105 2780 B 70 x 20 (1) � Maxi 40 301254T4 C 105 2780 B 70 x 20 (1) Maxi 40 301255

(1) With flange - Without pressure regulator. Hub Ø 70, entraxe flange : 150mm - Shaft Ø 20mm - Range 104 replaced by 105

NOTE : This range of pump may be fitted with a preheater. No adjusting screw. Maxi pressure 30 bars.

Oil pump

CSB.168

Oil p

ump

PO

Page 11: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SUNTEC PUMP - SUNDSTRAND FUELSUNDSTRAND PUMP IDENTIFICATION TABLE

A AMSUNDSTRAND

A60 Type nozzle capacity l/h Strainer Rotation Pressure range

bar Fixing without nozzle Hub without meaning

A : Normal 1 = 18 A = without A = Right L = 5 - 10 1 = Flange 0 or 1 1 = Ø 32 0 to 9AM : with EV 2 = 25 Z = without C =Left M = 7 - 14 2 = Hub 2 = Ø 54

3 = 15 P = 10 - 18 4 = Ø 54Example � A 2 Z C M 2 0 1 4

Example for replacement : A2ZCM2014 is replaced by AN 47C 7328 ref 301750

SUNTEC PUMP IDENTIFICATION TABLE

AN AS AP - AL AT

SUNTEC TypeFlow 2800

tr/mn10 bars

RotationOutlet nozzle side

Hub ØInlet/return Range Voltage Cable

A = FODL = with in line cut-off solenoid

valve35 = 40l/h A = right right 2-7-8 = 1/4"

Revision N°

P = Screw by pass plugged

01 = 110V00 = without25 = 25 cm

65 = 82l/hB = right left 95 = Ø32 4 = 1/8" 02 = 24V

35 = 35 cm45 = 45 cm

C = left left Bleed pipe 05 = 220V 60 = 60 cmD = left right 10 = 1m

Example AL 35 A 95 2 8 1 P 05 35

SUNTEC TypeFlow 2800

tr/mn10 bars

Rotation Outlet nozzle side Range Hub without

meaning

A = FOD AN = without solenoid valve 47 = 40l/h A = right right 7 = 1970 2 = Ø54

2 digitsRevision

P = Screw bypassplugged

D = without solenoid valve 57 = 58l/h B = right left 1 = 1992 3 = Ø32AE = Pressure regulatorwithout in line cut-off

67 = 80l/h C = left left 1 = For same models7 = with

4 = Ø54

AS = with solenoid valve 77 = 110l/h D = left right 5 = Ø32AP = with solenoid valve 2 stages

97 = 130l/hlateral pressure

portAT2 2 stages with in line cut-off 45 = 45l/h A = right right 1 = withoout 95 = Ø32

AT3 same as AT2 + pressure plug on cover

B = right leftC = left leftD = left right

Example AS 57 C 7 4 41 3 P

AJ J and E T TA

SUNTEC TypeFlow 2800

tr/mn10 bars

Rotation Outlet nozzle side

Pressurein bar Flange Features

AJ = FOD 4 = 110l/h A = right right C - 10 to 20 1 = with 000 = standard

Revision N°

P = Screw bypass plugged

6 = 200l/h C = left left E - 10 to 30 + Hub002 = Pierced nozzle, outlet

no cut-off

D = left right Ø54 003 = shaft Ø8 without off

Example AJ 6 D C 1 003 2 P

SUNTEC TypeFlow 2800

tr/mn10 bars

Filter Rotation Outlet no-zzle side

Pressurein bar Flange Features

J = FOD 3 = 90l/h C A = right right B - 7 to 14 1 = with 000 = 1/2 conicRevision

N°P = Screw bypass

plugged4 = 110l/h B = right left C - 10 to 216 = 205l/h C = left left K - 14 to 30 001 = 1/2 cylindric7 = 300l/h D = left right

Example J 3 C B B 1 000 4 P

Oil pump

CSB.169

Oil p

ump

PO

Page 12: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SUNTEC PUMP IDENTIFICATION TABLE (continuation)

AJ J and E T TA

SUNTEC Type Flow 2800 tr/mn15 bars to 20cst Filter Rotation Outlet nozzle

side Flange Features

E = FL 4 = 130l/h C = 170mM A = right right 10 = with 01 = standardRevision

N°P = Screw bypass

plugged6 = 228l/h B = right left 69 = Cover with hole for

heating element7 = 340l/h C = left leftN = 550mM D = left right

Example E 4 N C 10 69 5 P

SUNTEC Type Flow 2800 tr/mn10 bars Rotation Pressure Features

TA = FL or FOD 2 = 500l/h A = right 30 = 7 to 30 bar

10 = Cover with hole for heating element Revision N°3 = 760l/h C = left 40 = 7 to 40 bar4 = 1000l/h5 = 1360l/h

Example TA 2 C 40 10 5T = FL or FOD 2 = 1400l/h A = right

10 = Cover with hole for heating element Revision N°3 = 2000l/h C = left4 = 2900l/h5 = 3950l/h

Example T 4 C 10 5

SUNTEC PUMP ACCESSORIESSHAFT SEAL REPAIR KIT

Description Mark Ref

AN - AS - AE - AL - AT - D - AP - A2L type (SUNTEC ref. 991515/991511) 1 301391AJ type (SUNTEC ref. 270202) 1 301342J - H - E 1000/1001 type (SUNTEC ref. 993473) 2 301340E 1063/1069 type (SUNTEC ref. 132632) 2 301362T type Revision 3 Shaft seal kit (SUNTEC ref. 991911) 3 301383T type Revision 4/5 Shaft seal kit (SUNTEC ref. 1914462) 3 301380TA type Revision 2/4/5 Shaft seal kit(SUNTEC ref. 2014462) 3 301381

Shaft E4 type 1063/1069 (SUNTEC ref. 993009) 4 301363Shaft E6 - E7 type 1063/1069 (SUNTEC ref. 993010) 4 301364

Shaft seal wrench Ø 4mm entraxe 25mm J - H - E (SUNTEC ref. 27005) 5 301370

COVER GASKET Description Mark Ref

AJ gasket (original piece) (SUNTEC ref. 270112) 1 301436AJ gasket (adaptable piece) 1 301435AJ gasket (original piece) 1 301437J - H - E gasket (original piece) (SUNTEC ref. 110441/135803) 2 301411J - H - E gasket (adaptable piece) 2 301410J - H - E gasket (original piece) 2 301412A1 - A2 gasket 3 301420

AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast coverAN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 revision 1-2-5 - AT2/AT3 45-55-65 range 9000 revision 1-2-5 - AP2/AP3 45-55-65 range 9000 revision 1 - AN/AE 77-97 range 7000 revision 3 - AL/A2L/AR/AT2 75-95 range 9000 revision 2 and 5 - AP2 75-95 range 9000 revision 1 - new aluminium cover 82 (width 0,65mm)(original piece) 4 301433

AN - AS - AE - AL - AP - AT gasket (SUNTEC ref. 3759811/991523)AN/AE/AS/AP 47-57-67 range 7000 rev.2 cast cover - AN/AE 77-97 range 7000 rev.2 cast coverAN/AE/AS/AP 47-57-67 range 7000 rev.3 and 5 - AN/AE/AS/AP 47-57-67 range 1000 rev.1 and 5 - AL/ALE/A2L/AR 35-55-65 range 9000 rev.1-2-5 - AT2/AT3 45-55-65 range 9000 rev.1-2-5 - AP2/AP3 45-55-65 serie 9000 rev.1 - AN/AE 77-97 range 7000 rev.3 - AL/A2L/AR/AT2 75-95 serie 9000 rev.2 and 5 - AP2 75-95 range 9000 rev.1 new aluminium cover 82 (width 0,65mm) (adaptable piece) 4 301432

1

2

3

4

x 12

x 10

x 12

x 10

x 12

x 10

x 12

1

2

3

4

5

Oil pump

CSB.170

Oil p

ump

PO

Page 13: Oil Pumps - Boiler Parts - Boilerparts.co.ke

COVER GASKET (continuation) Description Mark Ref

AN - AS - AE - AP gasket (SUNTEC ref. 991524) AN/AE/AS/AP 47-57-67 range 7000 rev.4 and 6 fl ate cover - AN/AE/AS/AP 47-57-67 range 1000 rev.4 and 6 fl ate cover - AL/ALE 35-55-65 range 9000 rev.4 and 6 - AT2/AT3 45-55-65 range 9000 rev.4 and 6 - AP2/AP3 45-55-65 range 9000 rev.4 et 6 - new fl ate cover (original piece) x 10 - 301434

cover Kit AN - AS - AE - AL - AP - AT rotation A-D (range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991475) 5 301580cover Kit AN - AS - AE - AL - AP - AT rotation B-C(range 35-45-55-65-47-57-67 Rev 2-3) (SUNTEC ref. 991476) 5 301581cover Kit AN-AE-AP2-AT2-AL-ALE-A2L-AR rotation B-C(range 75-95-77-97 Rev 3) (SUNTEC ref. 991509) 5 301582

STRAINER PUMP

Description Mark Ref

AN/AS/AE/AP range 47-57-67 range 7000 rev.3-4-5-6 aluminium cover (SUNTEC ref. 3715741) 2 301561AN/AS/AE/AP 47-57-67 range 1000 rev.1-4-5-6 without bosses - AL/ALE/A2L/AR/AT2/AT3/AP2/AP3 range 9000 rev.1-2-4-5-6 (SUNTEC ref. 3715741) 2 301561AN/AE 77-97 range 7000 revision 2 (SUNTEC ref. 3715732) 3 301563A1/A2/AN/AS/AE/AP range 47-57-67 rev. 2 (SUNTEC ref. 3715735/3715732) 3 301563AJ 39 mm (SUNTEC ref. 270087) 4 301565J - H - E Filter "C" - 170µ 55mm (SUNTEC ref. 134423) 4 301540E Filter "N"-550µ SUNTEC (ref. 134433) 4 301550AP2 - AT2 75 and 95 (SUNTEC ref 3715750) - 301566D revision 3 (SUNTEC ref. 3715747) - 301567

SOLENOID KIT Description Mark Ref

Solenoid kit All AS types 220 volts (SUNTEC ref. 991435) 1 301470Solenoid kit All AS types 110 volts (SUNTEC ref. 991431) 1 301473Solenoid kit All AP types 220 volts for 47/57/67 (SUNTEC ref. 991455) 1 301472Solenoid kit All AL types 220 volts revision 2 - 4 - 5 - 6 (SUNTEC ref. 3713798/991502) 1 301468Solenoid kit All AT types rot.A/D revision 2 (SUNTEC ref. 3713798/991503) 2 301466Solenoid kit AP 2/3 rot.B/C (SUNTEC ref. 991489) 2 301474

SOLENOID VALVE COIL Description Ref

Solenoid valve coil 220 volts (SUNTEC ref. 3713798) 301478Solenoid valve coil 110 volts (SUNTEC ref. 3713797) 301479Solenoid valve coil 24 volts (SUNTEC ref. 3713796) 301477Solenoid valve coil 24 volts continuous (SUNTEC ref. 3713818) 301481

SOLENOID VALVE CONNECTOR

Description RefAMP moulded connector with 3 leads 0.40m, for Rapa valve and SUNTEC solenoid valves 803030AMP moulded connector with 3 leads 0,80m, for Rapa valve and SUNTEC solenoid valves 803029AMP moulded connector for Rapa valve and SUNTEC solenoid valves 803034

CHANGING KIT PUMP - BY PASS PLUG

Description RefChanging AU pump kit to AE pump (SUNTEC ref.991401) 301589Changing AS pump kit to AN pump (SUNTEC ref.991400) 301590By-pass plug for AN-AS-AL-AP-AT-D pump (SUNTEC ref.3779858) 301469

5

1

2

4

x 6x 6x 1

x 6

Oil pump

CSB.171

Oil p

ump

PO

Page 14: Oil Pumps - Boiler Parts - Boilerparts.co.ke

FLANGE AND ADAPTER HUB Description Mark Ref

Flange with 2 holes entraxe 92 mm (SUNTEC ref.132752) 1 301300Flange for changing hub 32mm without fl ange to hub 54mm with fl ange (SUNTEC ref.3719003) 2 301301Adapter Hub to obtain hub ø 54 mm with hub ø 32 mm (SUNTEC ref.3759833) 3 301310Shaft Extension to obtain ø 11,11 with shaft ø 8 mm (SUNTEC ref.3754737) 4 601130

ELECTRIC PREHEATER AND REGULATOR

Description Mark RefElectric preheater for heavy fuel oil cover pump type E 1069 T/TA 1 404956Regulator kit for pump J 1069 T/TA (SUNTEC ref.991410) 2 301450Low pressure regulator replaces only on AJ pump, Revision 2 only, the original regulator to get an adjusting range 0,7 to 3 bars (SUNTEC ref.270716) 3 301452Low pressure regulator replaces on AN-AS-AE-AL-AT-AP pump, revision 2 only, the original regulator to get an adjusting range for 0,7 to 3 bars (SUNTEC ref.991500) 3 301453

ATCO - FRANCIA - SICMA PUMPRANGE of PUMP REPLACED by SUNTEC Range P4 - M7 - M9 - M11 - M13 - M15. This pump is not yet manufactured. Replaced by SUNTEC pump with same technical features...

Type Flow l/h to 2800 tr/mn & 10 bar

Ø Hub and shaft in mm

Characte-ristic Rotation Nozzle outlet Ref

P4 - LL 28 M 32x8 301750P4- RL 28 M 32x8 � 301044P4 - LL Sib or PV4 with solenoid valve 28 M 32x8 301088P4 - RL Sib or PV4 with solenoid valve 28 M 32x8 � 301084M15 - R15 170 B 54x11.11 (1)(2) � � 301604M15 - L15 (2) 301605

(1) With fl ange - (2) Delivered with adapter kit Nota : These pumps replace ATCO pumps, not fi tted with ring for air fl ap

DANFOSS PUMPDANFOSS PUMPS IDENTIFICATION TABLE

RS MS MS21 BFPDANFOSS Type Rotation Flow to 2800 tr/mn

Adjustment 10 bars Size shaft By-pass screw

RS without EV 43 = 12l/h 2-3 = Ø8RSA without EV right left 31 = 32l/h 0 = no pluggedRSH without EV 53 = 45l/h 0-3-5-7 = Ø10RSL without EV 070 070L 32 = 75l/h 2 = plugged

RSLB without EV 33 = 100l/h 1-4-6-8 = Ø11,11Example � RS 60 070L 33 6 2

MSLA with EV right leftMSLB without EV 071B0 071B1 032 = 24l/h 10 or 20 = Ø8 2-4-6-8 = pluggedMSLC without EV 071B2 071B3 050 = 52l/h hub Ø32 1-3-5-7 = no plugged

071B4 071B5Example � MSLB 071B3 032 10 2

MS10 without EV

R L3 = 45l/h 071G0...

no meaningMS11 with EVMS12 with EV 5 = 70l/hMS21 with EV

Example � MS11 R 3 071G0126

12

34

1

2

3

Oil pump

CSB.172

Oil p

ump

PO

Page 15: Oil Pumps - Boiler Parts - Boilerparts.co.ke

DANFOSS PUMP

DANFOSS OLD PUMP REPLACEMENT TABLEComponent Description Manufact. ref

DANF 70-3130 Danfoss pump 70-3130 70-3130 = 303432DANF 70-3132 70-3132 70-3132 = 303432DANF 70-3140 70-3140 303432 + 301310DANF 70-3142 70-3142 303432 + 301310 DANF 70-3200 70-3200 70-3200 = 303031 DANF 70-3202 70-3202 70-3202 = 303031 DANF 70-3210 70-3210 70-3210 = 303033 DANF 70-3212 70-3212 70-3212 = 303033 DANF 70-3230 70-3230 70-3230 = 303031 DANF 70-3232 70-3232 70-3232 = 303031 DANF 70-3240 70-3240 70-3240 = 303033 DANF 70-3242 70-3242 70-3242 = 303033 DANF 70-3300 70-3300 -DANF 70-3302 70-3302 -DANF 70-3310 70-3310 70-3310 = 303043 DANF 70-3312 70-3312 70-3312 = 303043 DANF 70-3350 70-3350 -DANF 70-3352 70-3352 -DANF 70-3360 70-3360 70-3360 = 303043 DANF 70-3362 70-3362 70-3362 = 303043 DANF 70-3410 70-3410 70-3410 = 303093 DANF 70-3412 70-3412 70-3412 = 303093 DANF 70-4030 70-4030 70-4030 = 303430 DANF 70-4032 70-4032 70-4032 = 303430 DANF 70-4040 70-4040 303430 + 301310 DANF 70-4042 70-4042 303430 + 301310 DANF 70-4120 70-4120 70-4120 = 303430 DANF 70-4121 70-4121 70-4121 = 303430 DANF 70-4130 70-4130 70-4130 = 303432 DANF 70-4132 70-4132 70-4132 = 303432 DANF 70-4140 70-4140 303432 + 301310 DANF 70-4142 70-4142 303432 + 301310 DANF 70-4330 70-4330 70-4330 = 303430 DANF 70-4332 70-4332 70-4332 = 303430 DANF 70-4340 70-4340 303430 + 301310 DANF 70-4342 70-4342 303430 + 301310 DANF 70-4492 70-4492 70-4492 = 303432 DANF 70-5300 70-5300 70-5300 = 303021 DANF 70-5302 70-5302 70-5302 = 303021 DANF 70-5322 70-5322 70-5322 = 303025 DANF 70-5330 70-5330 70-5330 = 303025 DANF 70-5332 70-5332 70-5332 = 303025 DANF 70-5370 70-5370 70-5370 = 303021 DANF 70-5372 70-5372 70-5372 = 303021 DANF 70-6400 70-6400 70-6400 = 301171 DANF 70-6410 70-6410 70-6410 = 301171 DANF 70-6480 70-6480 70-6480 = 301161 DANF 70-7300 70-7300 70-7300 = 301151 DANF 70-7310 70-7310 70-7310 = 301151

DANF 70L 3002 70L 3002 - DANF 70L 3130 70L 3130 70L 3130 = 303433 DANF 70L 3132 70L 3132 70L 3132 = 303433 DANF 70L 3140 70L 3140 303433 + 301310 DANF 70L 3142 70L 3142 303433 + 301310 DANF 70L 3200 70L 3200 -DANF 70L 3202 70L 3202 -DANF 70L 3210 70L 3210 70L 3210 = 303034 DANF 70L 3212 70L 3212 70L 3212 = 303034 DANF 70L 3230 70L 3230 -DANF 70L 3232 70L 3232 -DANF 70L 3240 70L 3240 70L 3240 = 303034 DANF 70L 3242 70L 3242 70L 3242 = 303034 DANF 70L 3300 70L 3300 70L 3300 = 303042 DANF 70L 3302 70L 3302 70L 3302 = 303042 DANF 70L 3310 70L 3310 70L 3310 = 303044 DANF 70L 3312 70L 3312 70L 3312 = 303044 DANF 70L 3350 70L 3350 70L 3350 = 303042 DANF 70L 3352 70L 3352 70L 3352 = 303042 DANF 70L 3360 70L 3360 70L 3360 = 303044 DANF 70L 3362 70L 3362 70L 3362 = 303044 DANF 70L 3400 70L 3400 70L 3400 = 303092 DANF 70L 3402 70L 3402 70L 3402 = 303092 DANF 70L 3410 70L 3410 70L 3410 = 303094 DANF 70L 3412 70L 3412 70L 3412 = 303094 DANF 70L 3480 70L 3480 70L 3480 = 303054 DANF 70L 3482 70L 3482 70L 3482 = 303054 DANF 70L 4030 70L 4030 70L 4030 = 303431 DANF 70L 4032 70L 4032 70L 4032 = 303431 DANF 70L 4040 70L 4040 303431 + 301310 DANF 70L 4042 70L 4042 303431 + 301310 DANF 70L 4130 70L 4130 70L 4130 = 303433 DANF 70L 4132 70L 4132 70L 4132 = 303433

Component Description Manufact. refDANF 70L 4140 Danfoss pump 70L 4140 303433 + 301310 DANF 70L 4142 70L 4142 303433 + 301310 DANF 70L 4330 70L 4330 70L 4330 = 303431 DANF 70L 4332 70L 4332 70L 4332 = 303431 DANF 70L 4340 70L 4340 303433 + 301310 DANF 70L 4342 70L 4342 303431 + 301310 DANF 70L 5300 70L 5300 70L 5300 = 303022 DANF 70L 5302 70L 5302 70L 5302 = 303022 DANF 70L 5310 70L 5310 70L 5310 = 303024 DANF 70L 5312 70L 5312 70L 5312 = 303024 DANF 70L 5322 70L 5322 70L 5322 = 303026 DANF 70L 5330 70L 5330 70L 5330 = 303026 DANF 70L 5332 70L 5332 70L 5332 = 303026 DANF 70L 5370 70L 5370 70L 5370 = 303022 DANF 70L 5372 70L 5372 70L 5372 = 303022 DANF 70L 5380 70L 5380 70L 5380 = 303024 DANF 70L 5382 70L 5382 70L 5382 = 303024 DANF 70L 5392 70L 5392 70L 5392 = 303026 DANF 70L 6400 70L 6400 70L 6400 = 301173 DANF 70L 6410 70L 6410 70L 6410 = 301173 DANF 70L 6480 70L 6480 70L 6480 = 301163 DANF 70L 7300 70L 7300 70L 7300 = 301153 DANF 70L 7310 70L 7310 70L 7310 = 301153 DANF 71B 0030 71B 0030 -DANF 71B 0101 71B 0101 71B 0101 = 303400 DANF 71B 0102 71B 0102 71B 0102 = 303400 DANF 71B 0103 71B 0103 303400 + 303357 DANF 71B 0104 71B 0104 303400 + 303357 DANF 71B 0105 71B 0105 303400 + 303357 DANF 71B 0106 71B 0106 303400 + 303357 DANF 71B 0107 71B 0107 71B 0107 = 303400 DANF 71B 0108 71B 0108 71B 0108 = 303400 DANF 71B 0112 71B 0112 71B 0112 = 303400 DANF 71B 0113 71B 0113 71B 0113 = 303400 DANF 71B 0132 71B 0132 303400 + 303359 DANF 71B 0201 71B 0201 71B 0201 = 303402 DANF 71B 0202 71B 0202 71B 0202 = 303402 DANF 71B 0203 71B 0203 303402 + 303357 DANF 71B 0204 71B 0204 303402 + 303357 DANF 71B 0205 71B 0205 303402 + 303357 DANF 71B 0206 71B 0206 303402 + 303357 DANF 71B 0207 71B 0207 71B 0207 = 303402 DANF 71B 0208 71B 0208 71B 0208 = 303402 DANF 71B 1101 71B 1101 71B 1101 = 303401 DANF 71B 1102 71B 1102 71B 1102 = 303401 DANF 71B 1103 71B 1103 303401 + 303357 DANF 71B 1104 71B 1104 303401 + 303357 DANF 71B 1105 71B 1105 303401 + 303357 DANF 71B 1106 71B 1106 303401 + 303357 DANF 71B 1107 71B 1107 303401 + 303357 DANF 71B 1108 71B 1108 71B 1108 = 303401 DANF 71B 1111 71B 1111 71B 1111 = 303401 DANF 71B 1112 71B 1112 71B 1112 = 303401 DANF 71B 1114 71B 1114 303401 + 303357 DANF 71B 1116 71B 1116 303401 + 303357 DANF 71B 1120 71B 1120 71B 1120 = 303401 DANF 71B 1122 71B 1122 71B 1122 = 303401 DANF 71B 1126 71B 1126 303401 + 303357 DANF 71B 1128 71B 1128 71B 1128 = 303401 DANF 71B 1132 71B 1132 303401 + 303359 DANF 71B 1134 71B 1134 71B 1134 = 303401 DANF 71B 1136 71B 1136 71B 1136 = 303401 DANF 71B 1138 71B 1138 71B 1138 = 303401 DANF 71B 1201 71B 1201 71B 1201 = 303403 DANF 71B 1202 71B 1202 71B 1202 = 303403 DANF 71B 1203 71B 1203 303403 + 303357 DANF 71B 1204 71B 1204 303403 + 303357 DANF 71B 1206 71B 1206 303403 + 303357 DANF 71B 1207 71B 1207 71B 1207 = 303403 DANF 71B 1208 71B 1208 71B 1208 = 303403 DANF 71B 2101 71B 2101 71B 2101 = 303430 DANF 71B 2102 71B 2102 71B 2102 = 303430 DANF 71B 2104 71B 2104 71B 2104 = 303430 DANF 71B 2201 71B 2201 71B 2201 = 303432 DANF 71B 2202 71B 2202 71B 2202 = 303432 DANF 71B 2203 71B 2203 71B 2203 = 303432 DANF 71B 3101 71B 3101 71B 3101 = 303431 DANF 71B 3102 71B 3102 71B 3102 = 303431 DANF 71B 3103 71B 3103 71B 3103 = 303431 DANF 71B 3201 71B 3201 71B 3201 = 303433 DANF 71B 3202 71B 3202 71B 3202 = 303433 DANF 71B 4101 71B 4101 71B 4101 = 303430

Oil pump

CSB.173

Oil p

ump

PO

Page 16: Oil Pumps - Boiler Parts - Boilerparts.co.ke

DANFOSS PUMP

DANFOSS OLD PUMP REPLACEMENT TABLEComponent Description Manufact. ref

DANF 71B 4102 Danfoss pump 71B 4102 71B 4102 = 303430 DANF 71B 4103 71B 4103 71B 4103 = 303432 DANF 71B 4105 71B 4105 71B 4105 = 303430 DANF 71B 4201 71B 4201 71B 4201 = 303432 DANF 71B 4202 71B 4202 71B 4202 = 303432 DANF 71B 5101 71B 5101 71B 5101 = 303431 DANF 71B 5102 71B 5102 71B 5102 = 303431 DANF 71B 5201 71B 5201 71B 5201 = 303433 DANF 71B 5202 71B 5202 71B 5202 = 303433 DANF 71B 6101 71B 6101 71B 6101 = 303430 DANF 71B 6102 71B 6102 71B 6102 = 303430 DANF 71B 6201 71B 6201 71B 6201 = 303432 DANF 71B 6202 71B 6202 71B 6202 = 303432 DANF 71B 7101 71B 7101 71B 7101 = 303431 DANF 71B 7102 71B 7102 71B 7102 = 303431 DANF 71B 7201 71B 7201 71B 7201 = 303433 DANF 71B 7202 71B 7202 71B 7202 = 303433 DANF 71G 0113 71G 0113 not replacedDANF 71G 0114 71G 0114 not replacedDANF 71G 0115 71G 0115 not replacedDANF 71G 0116 71G 0116 not replacedDANF 71G 0117 71G 0117 71G 0117 = 303401 DANF 71G 0118 71G 0118 71G 0118 = 303400 DANF 71G 0119 71G 0119 71G 0119 = 303436 DANF 71G 0120 71G 0120 71G 0120 = 303437 DANF 71G 0121 71G 0121 71G 0121 = 303401 DANF 71G 0123 71G 0123 71G 0123 = 303430 DANF 71G 0124 71G 0124 71G 0124 = 303432 DANF 71G 0125 71G 0125 71G 0125 = 303431 DANF 71G 0126 71G 0126 71G 0126 = 303402 DANF 71G 0127 71G 0127 71G 0127 = 303403 DANF 71G 0128 71G 0128 71G 0128 = 303433 DANF 71G 0129 71G 0129 71G 0129 = 303434 DANF 71G 0130 71G 0130 71G 0130 = 303435 DANF 71G 0134 71G 0134 71G 0134 = 303401 DANF 71G 0137 71G 0137 71G 0137 = 303401 DANF 71G 0139 71G 0139 71G 0139 = 303401 DANF 71G 0140 71G 0140 71G 0140 = 303435 DANF 71G 0153 71G 0153 not replacedDANF 71G 0154 71G 0154 =303401+601031/404143 DANF 71G 0156 71G 0156 71G 0156 = 303090 DANF 71G 0157 71G 0157 71G 0157 = 303401 DANF 71G 0158 71G 0158 71G 0158 = 303401 DANF 71G 0160 71G 0160 303400 + 303359 DANF 71G 0161 71G 0161 not replacedDANF 71G 0165 71G 0165 71G 0165 = 303401 DANF 71G 0167 71G 0167 71G 0167 = 303400 DANF 71G 0173 71G 0173 71G 0173 = 303400 DANF 71G 0174 71G 0174 71G 0174 = 303402 DANF 71G 0175 71G 0175 71G 0175 = 303430 DANF 71G 0176 71G 0176 71G 0176 = 303432 DANF 71G 0177 71G 0177 71G 0177 = 303400 DANF 71G 0178 71G 0178 71G 0178 = 303401 DANF 71G 0179 71G 0179 71G 0179 = 303401 DANF 71G 0181 71G 0181 71G 0181 = 303437 DANF 71N 0102 71N 0102 303401 DANF 71N 0103 71N 0103 303401 DANF 71N 0104 71N 0104 303401 DANF 71N 0105 71N 0105 303403 DANF 71N 0107 71N 0107 303401 DANF 71N 0108 71N 0108 303431 DANF 71N 0109 71N 0109 303400 DANF 71N 0111 71N 0111 303401 DANF 71N 0113 71N 0113 303401 DANF 71N 0114 71N 0114 =303401+601031/404143 DANF 71N 0102 71N 0102 303401 DANF 71N 0115 71N 0115 303401 DANF 71N 0116 71N 0116 303403 DANF 71N 0118 71N 0118 303430 DANF 71N 0119 71N 0119 303401 DANF 71N 0120 71N 0120 303403 DANF 71N 0122 71N 0122 303401 DANF 71N 0123 71N 0123 303401+303357 DANF 71N 0125 71N 0125 303431 DANF 71N 0126 71N 0126 71N 0126 = 303433 DANF 71N 0127 71N 0127 303431 DANF 71N 0128 71N 0128 303430 DANF 71N 0129 71N 0129 71N 0129 = 303432 DANF 71N 0130 71N 0130 303401 DANF 71N 0132 71N 0132 303401 DANF 71N 0133 71N 0133 =303401+601031/404143 DANF 71N 0135 71N 0135 303401 DANF 71N 0136 71N 0136 303400

Component Description Manufact. refDANF 71N 0137 Danfoss pump 71N 0137 303400 DANF 71N 0137 71N 0137 303400DANF 71N 0141 71N 0141 303401 DANF 71N 0142 71N 0142 303401 DANF 71N 0143 71N 0143 303400 DANF 71N 0144 71N 0144 303401 DANF 71N 0145 71N 0145 303400 DANF 71N 0147 71N 0147 303401 DANF 71N 0148 71N 0148 303401 DANF 71N 0149 71N 0149 303401 DANF 71N 0150 71N 0150 303401 DANF 71N 0151 71N 0151 303401 DANF 71N 0152 71N 0152 303401 DANF 71N 0153 71N 0153 303401+303359 DANF 71N 0154 71N 0154 303401+303359 DANF 71N 0155 71N 0155 303400 DANF 71N 0156 71N 0156 303401 DANF 71N 0157 71N 0157 303400 DANF 71N 0158 71N 0158 303403 DANF 71N 0159 71N 0159 303402 DANF 71N 0160 71N 0160 303401 DANF 71N 0161 71N 0161 303431 DANF 71N 0162 71N 0162 303430 DANF 71N 0163 71N 0163 303402 DANF 71N 0164 71N 0164 303401 DANF 71N 0165 71N 0165 303402 DANF 71N 0166 71N 0166 303432 DANF 71N 0167 71N 0167 303400 DANF 71N 0168 71N 0168 71N 0168 = 303431 DANF 71N 0169 71N 0169 71N 0169 = 303430 DANF 71N 0170 71N 0170 303401 DANF 71N 0171 71N 0171 71N 0171 = 303400 DANF 71N 0172 71N 0172 71N 0172 = 303403 DANF 71N 0173 71N 0173 71N 0173 = 303402 DANF 71N 0174 71N 0174 71N 0174 = 303401 DANF 71N 0175 71N 0175 303401 DANF 71N 0176 71N 0176 303401+303359 DANF 71N 0177 71N 0177 303430 DANF 71N 0178 71N 0178 303403 DANF 71N 0179 71N 0179 303401 DANF 71N 0180 71N 0180 303432 DANF 71N 0182 71N 0182 303401 DANF 71N 0183 71N 0183DANF 71N 0184 71N 0184 303401 DANF 71N 0185 71N 0185 303401 DANF 71N 0188 71N 0188 303401 DANF 71N 0189 71N 0189 303401+303359 DANF 71N 0190 71N 0190 303401 DANF 71N 0191 71N 0191 303400 DANF 71N 0192 71N 0192 303401 DANF 71N 0193 71N 0193 303401 DANF 71N 0194 71N 0194 303403 DANF 71N 0195 71N 0195 303402 DANF 71N 0196 71N 0196 303400 DANF 71N 0197 71N 0197 303401 DANF 71N 0198 71N 0198 303400 DANF 71N 0202 71N 0202 303403 DANF 71N 0203 71N 0203 71N 0203 = 303401 DANF 71N 0204 71N 0204 no replacedDANF 71N 0207 71N 0207 303402 DANF 71N 0208 71N 0208 303400 DANF 71N 0210 71N 0210 303401 DANF 71N 0212 71N 0212 = 303431+601031/404143 DANF 71N 0213 71N 0213 303401 DANF 71N 0214 71N 0214 303400 DANF 71N 0215 71N 0215DANF 71N 0217 71N 0217 303401 DANF 71N 0218 71N 0218 303431 DANF 71N 2205 71N 2205 303437 DANF 71N 2206 71N 2206 303436 DANF 71N 2211 71N 2211 = 303435+601031/404143 DANF 71N 2212 71N 2212 = 303437+601031/404143 DANF 71N 2213 71N 2213 303435

Oil pump

CSB.174

Oil p

ump

PO

Page 17: Oil Pumps - Boiler Parts - Boilerparts.co.ke

DANFOSS PUMPMS10 - MS12 Range

Type Technical feature

Flow l/h to 2800 tr/mn &

10 bars

Ø Hub and Shaft in mm Rotation Outlet nozzle

side Ref

MS 10R5 - 071G0124 - 50 32x8 � � 303077MS 12 EL3 - 071G0140 - 50 32x8 � 426240

Note : Automatic change over from two pipe operation to one pipe operation and inversely for MS10 - MS11 - MS12

MS12 Range with 2 solenoid valvesRange of pump MS 12 E is replaced by range of pump BFP 52 E. Range of pump MS 12 without hydraulic air jack is replaced by range of pump BFP 52 ERange of pump MS 12 with hydraulic air jack is replaced by the following

Description RefMS 12 R3 replaced by AT3 45B 9575 2P0500 301134MS 12 L3 replaced by AT3 45C 9558 2P0500 301135MS 12 L5 replaced by AT3 55C 9550 2P0500 301131

RS / RSA Range wihout solenoid valveApplication :Danfoss oil pump type RSA is an universal safety working pump made from well known Danfoss RS pump. Pump RSA is equipped with an hydraulic adjusting and closing valve allowing the installation on burner with 1,2 or many fl ow rates.

Type Flow l/h to 2800 tr/mn & 10 bars

Ø Hub and Shaft in mm Rotation Outlet nozzle

sideShaft

* Ref

RS / RSA 28-070 5372 45 54x10 � � S 303021RS / RSA 28-070 L5372 - - S 303022RS / RSA 28-070 L5382 45 54x11,11 L 303024RS / RSA 28-070 5332 45 54x8 � S 303025RS / RSA 28-070 L5332 - - S 303026RS / RSA 40-070 L3232 - - S 303032RS / RSA 40-070 3242 75 54x11,11 � L 303033RS / RSA 40-070 L3242 - - L 303034RS / RSA 60-070 L3356 - - S 303042RS / RSA 60-070 3362 100 54x11,11 � L 303043RS / RSA 60-070 L3362 - - L 303044RSA 95-70 L3482 182 54x11,11 L 303054RSA 125-70 L3412 274 54x11,11 L 303094

* S = Short shaft L = Long shaft

BFP 20 Range without solenoid valveThe pressure range depends on the pressure regulator position.Frontal screw adjusting 7 to 15 bars Lateral screw adjusting 7 to 20 bars.

Type Flow to 10 bars

Ø hub and shaft in

mmRotation outlet nozzle

side Ref

BFP 20 R3 - 071N0169 45 32x8 � � 303430BFP 20 L3 - 071N0168 45 32x8 � 303431BFP 20 R5 - 071N0129 70 32x8 � � 303432BFP 20 L5 - 071N0126 70 32x8 � 303433

BFP 21/41 Range with solenoid valveNo power cable supplied (see 803030)The pressure range depends on the pressure regulator position.Frontal screw adjusting 7 to 15 barsLateral screw adjusting 7 to 20 barsNote : for one pipe installation remove by pass plug inserted in the vacuum gauge port.

Type Flow to 10 bars

Ø hub and shaft in

mmRotation outlet nozzle

side Ref

BFP 21 R3 - 071N0171/0255 45 32x8 � � 303400BFP 21 L3 - 071N0170 45 32x8 � 303401BFP 41 L3 - 071N0174 45 32x8 303420BFP 41 R3 - 071NO235 45 32x8 � 303421BFP 21 R5 - 071N0173 70 32x8 � � 303402BFP 21 L5 - 071N0172 70 32x8 � � 303403

Rotation :� R = Right L = Left

Rotation� R : Right L = Left

Rotation :� R = Right L = Left

Rotation :� R = Right L = Left

Rotation :� R = Right L = Left

Oil pump

CSB.175

Oil p

ump

PO

Page 18: Oil Pumps - Boiler Parts - Boilerparts.co.ke

DANFOSS PUMPBFP 31 Range with solenoid valve

Type Flow to 10 bars

Ø hub and shaft in

mmRotation outlet nozzle

side Ref

BFP 31 L3 - 071N1201 45 32x8 401045

No power cable supplied (see 803030)The pressure range depends on the pressure regulator position.Frontal screw adjusting 7 to 15 barsLateral screw adjusting 7 to 20 barsNote : for one pipe installation remove by pass plug inserted in the vacuum gauge port.

BFP 52 Range with 2 solenoid valves

Type Flow to 10 bars

Ø hub and shaft in

mmRotation outlet nozzle side Ref

BFP 52 E R3 - 071N2203 45 32x8 � 303434BFP 52 E L3 - 071N2264 45 32x8 303435BFP 52 E R5 - 071N2204 70 32x8 � 303436BFP 52 E L5 - 071N2202 70 32x8 303437

No power cable supplied (see 803030)

The pressure range depends on the pressure regulator position.Frontal screw adjusting 7 to 15 barsLateral screw adjusting 7 to 20 bars

Type Manufacturer Ref

BFP 20 L3 - 071N0168 Hofamat - Klockner 303431

BFP 21 R3 - 071N0171/0255 Bentone - Klockner 303400

BFP 21 L3 - 071N0170 Chappée - Hofamat 303401

BFP 41 L3 - 071N0174Bentone - Brotje - Chappee - Hofamat

Korting - Viessman - Zaegel Held303420

Note : for one pipe installation remove by pass plug inserted in the vacuum gauge port.

BFP 21 LE Range with solenoid valve and drop stop

Type Flow to 10 bars

Ø hub and shaft in

mmRotation outlet nozzle

side Pression Ref

BFP 21 LE-3 - 071N2113 45 32x8 - 430755BFP 21 F3-LE-S - 071N2225 45 32x8 - 7/20 303404

Power cable not supplied (see 803030)

This pump can be used with DANFOSS OD-LE special nozzle to obtain drop stop function.The return valve can be shut down when standard nozzle is used.

Frontal adjusting screw 7 to 16 bars.

Type Manufacturer Ref

BFP 21 LE3 - 071N2113 Brotje 430755

Note : for one pipe installation remove by pass plug inserted in the vacuum gauge port.

BFP REMARKS

The ranges 20 - 21 -41 are designed to equip low power domestic burners (up to 500 Kw). They can replace existing burner pumps. Very easy strainer replacement. The range 52E is designed to equip two stages burners. Equipped with 2 adjusting valves with incorporated diaphragm. Equipped with 2 external solenoid valves, one for switching between low and high modes, the other for the nozzle pipe cut-off.

All BFP pumps are built with a trochoid gear and a graphite seal. Other informations : �R indicates right rotation � �L indicates left rotation always in front of the shaft �Nozzle outlet on the right or on the left �With or without solenoid valve �One-pipe or two-pipe pump (see the following proceeding)

Rotation :� R = Right L = Left

Rotation :� R = Right L = Left

Rotation :� R = Right L = Left

Oil pump

CSB.176

Oil p

ump

PO

Page 19: Oil Pumps - Boiler Parts - Boilerparts.co.ke

BFP REMARKS (continuation)

BFP 20/21/31/41/52E BFP 10/11(lateral regulation) BFP 20/21/31/41/52E BFP 10/11(lateral regulation)

One-pipe installation : screw not plugged Two-pipe installation : screw plugged

DANFOSS PUMP SUITCASE with 2 PUMPS

The BFP suitcase replaces MS21 suitcase only with 2 pumps. It is very interesting because there are many possibilities to install and replace the old pumps by the BFP pump.

�Outlet nozzle right or left �One pipe or two pipe installation �With ou without solenoid valve.

Suitcase composed of :1 pump BFP 21 R3 071N0171 ......... 3034001 pump BFP 21 L3 071N0170 .......... 3034011 adapter hub + flange ....................... 3033031 strainer ....................................... 3032471 coil 110 Volts .................................. 3033572 caps for solenoid valve shut down .. 3033711 wrench 3/4/5mm ........................... 9015101 suitcase ....................................... 9016021 shaft extension Ø8-Ø11,11 .............. 6011301 Kit ....................................... 602690 with 4 square 90°nipples M/F 1/4"-1/4" 2 reducers M1/4"-F1/8" 2 nipples M/M 1/8" 1 teflon roll ....................................... 9013521 coupling kit for :Chappee - Francia - Franco Belge - Joannes - Oertli - Riello - ZH ......601040

Description RefBFP pump suitcase 303001

DANFOSS PUMP ACCESSORIESFLANGE AND ADAPTER HUB

Description Mark RefADAPTER HUB type 071B0011 allows to obtain hub 54mm Ø with pump hub 32mm Ø used on range MSLA - MSLB - MSLC - MS. 1 303301ADAPTER HUB to obtain a 54mm Ø hub with all type of pump with a hub of 32mm Ø 2 301310FLANGE WITH ADAPTER HUB type 071B0012 92mm Ø for range MSLA - MSLB - MSLC - MS, BFP 3 303303FLANGE WITH ADAPTER HUB 92mm Ø for range RS - RSA - RSL - RSLB 4 303300

GASKET AND EXTENSION SHAFT

Description Mark RefEXTENSION SHAFT to obtain a 11,11 Ø with shaft pump 8 mm 1 601130Cover gasket MS - MSLA - MSLB - MSLC 2 303231

Cover gasket BFP 2 303232

STRAINER KIT WITH GASKET AND RING

Description Mark Ref

Kit for MS pump 1 303243Kit for RS - RSA 28/40/60 - RSL 050 - th. 23 DANFOSS 070-0032 pump 2 303244Kit for MSL pump 3 303246Kit + cartridge strainer for BFP pump 4 303247

1

34

2

1

2

12

34

x 12x 10

Oil pump

CSB.177

Oil p

ump

PO

Page 20: Oil Pumps - Boiler Parts - Boilerparts.co.ke

DANFOSS PUMP ACCESSORIESCONNECTOR Type AMP

Description RefConnector AMP white plastic 180-941 with 3 lead cables (ELCO, CUENOD) 803031Connector AMP white plastic 180-941 with 3 lead cables (ELCO, CUENOD) 803029

DANFOSS PUMP COIL

Description Mark RefFor BFP : 24 volts 1 303359110 volts 1 303357220 volts (071N0010 / 071N0051) 1 303358220 volts (071N0601 / 071N0054) 1 303355For MSLA :24 volts 2 303319220 volts 2 303330

DANFOSS SOLENOID VALVE CAP - STRAINER CAP

Description Mark RefWithout BFP o’ring 1 303371Strainer cap with Butt Joint for BFP pump 2 303372

SOLENOID PLUNGERDescription Ref

BFP Solenoid plunger type 071N0050 303362BFP Solenoid plunger type 071N3010 NO 303363

DELTA PUMP Range V / VMType Flow l/h to 2800

tr/mn & 10 barshub and Shaft Ø

in mm Rotation Outlet nozzle side Pressure bar Ref

Range without solenoid valveV1 RR 2 35 32x8 � 4 to 15 305511V1 RL 2 35 32x8 � � 4 to 15 305513V1 LR 2 35 32x8 4 to 15 305512V1 LL 2 35 32x8 � 4 to 15 305514V2 LR 2 57 32x8 4 to 15 305522Range with solenoid valveVM1 RR 2 35 32x8 � 4 to 15 305532VM1 RL 2 35 32x8 � � 4 to 15 305533VM1 LL 2 35 32x8 � 4 to 15 305534VM1 LR 2 35 32x8 4 to 15 305531VU1 35 32x8 � � 6 to 18 305515

Note : FUELMASTER pump is not yet manufactured but this pump can be replaced by DELTA pump (seethe following table). Outlet nozzle for FUELMASTER pump is on the left or on the right so you must use sometimes a highpressure hose code 602020

Origin pump Replacement RefZ1 RR or V1 RG BR V1 RR 2 305511Z1 LR or V1 LG BR V1 LR 2 305512Z1 RL or V1 RG BL V1 RL 2 305513Z1 LL or V1 LG BL V1 LL 2 305514Z2 RR or V2 RG BR not replacedZ2 LR or V2 LG BR V2 LR 2 305522Z2 RL or V2 RG BL not replacedZ2 LL or V2 LG BL V2 LL 2 305524ZM1 RR or VM1 RG BR VM1 RR 2 305532ZM1 RL or VM1 RG BL VM1 RL 2 305533ZM1 LL or VM1 LG BL VM1 LL 2 305534ZM1 LR or VM1 LG BR VM1 LR 2 305531

DELTA PUMP USING TABLE DELTA PUMP USING TABLEType Manufacturer Type Manufacturer

V1 LL 2 CUENOD VM1 LR 2 ELCO - KORTING - BALTURV1 LR 2 ELCO VM1 LL 2 BLOWTHERM - LAMBORGHINI

DELTA PUMP ACCESSORIESGASKET - STRAINER - COIL

Description Mark RefDelta strainer 12 mm 1 305503Cover gasket Z 1/2 and V 1/2 2 305505Strainer ZM 1 and VM 1 and V 1/2 3 305501Coil VM1 10mm Ø - 220V - height 33mm 4 305560

1

2

1

2

2

3

4

1

x 6x 6

x 10x 10

x 12

2

Oil pump

CSB.178

Oil p

ump

PO

Page 21: Oil Pumps - Boiler Parts - Boilerparts.co.ke

ECKERLE PUMPECKERLE PUMP IDENTIFICATION TABLE

UNI 1.1 UNI 1.2 UNI 2.1 UNI 2.2

ECKERLE Type Solenoid valve Rotation Flow to 2800 t/mn Adjustment 10 bars

Outlet nozzle side

Inlet Øreturn Ø

Electric connection

Pressurebar Hub Shaft Ø 8(2)

UNI 2 R = right 1 = 1/4 F 7 - 16 21 = without L = left 2 = 1/4 F 10 - 22 0= 32 2

replaces old BP1

2 = withR = right

1 = 25l/h

M* = left 4 = 1/4 C 7 - 16 2 = 54 2

3 = without5 =

40l/hS* = right 5 = 1/4 C 12 - 22

3=fl ange 92mm

1

4 = with6 =

75l/h *M and Swith elctronic

adapter

6 = 1/8 F 7 - 16 4 = 32 1

6 = without L = left 7 = 120l/h 7 = 1/8 F 10 - 22 5 = 54 1

8 = 1/8 C 7 - 166=fl ange 92mm

9 = 1/8 C 10 - 22Example � UNI2 2 L 5 L 1 4

F= Contact plug - C = cable

REPLACEMENT TABLE for ECKERLE PUMPS by SUNTEC

ECKERLE � SUNTECECKERLE Replacement by SUNTEC Features

Old type New type Type Ref To be added RefUNI1.1 L5 L64-10 UNI-E2.1 L1 L64 AN 47C 1342 301750 Inlet/Return 1/4UNI1.1 L5 L64-MI UNI-E2.1 L1 L64-21 AN 47C 1342 301750 Inlet/Return 1/4UNI1.2 L5 L64-50 UNI2.12 L1 L64 AL 35C 9540 301950UNI1.2 L5 L14-50 UNI2.12 L1 L14 AL 35C 9528 301957UNI1.2 L5 M14-50 UNI2.12 L1 M14 AL 35C 9528 301957UNI1.2 L5 L64-50 UNI2.12 L1 L64 AL 35C 9540 301950

UNI2.12 L1 M64 AL 35C 9540 301950UNI1.2 L5M64-50-W UNI2.12 L1 M64-65 AL 35C 9540 301950

UNI2.12 L6 M14 AL 65C 9589 301982UNI1.2L62M14-0-0-I-W UNI2.12 L6 M64-65 AL 65C 9589 301982UNI1.2L62 M14-01-W UNI2.12 L6M14-65 AL 65C 9589 301982UNI1.42L6 A64-W UNI2.42 L5L64-65 AT 245C9541 301120UNI1.72 L62 L14-W UNI2.17 L6 M14-65 AL 75C 9534 301983UNI2.1 G22 L1 L10 UNI-E 2.1 G22 AN 47C 1342 301750 + Coupling 601023UNI2.1 G22 L1 L40 UNI-E 2.1 G22 AN 47C 1342 301750 + Coupling 601023UNI2.1 G41-21 L1 L10 UNI-E 2.1 G41 AN 47C 1342 301750 + Coupling 601023

UNI-E 2.1 G41-13 AE 47C 1387 301799 + Coupling 601023UNI-E 2.1 L1 L10 AN 47C 1342 301750 + Coupling 601023UNI-E 2.1 L1 L10-22 AN 47C 1342 301750 + Coupling 601023

UNI2.1L1L44-21 UNI-E2.1 L1 L14 AN 47C 1342 301750UNI2.1 L1 L44-H1-21 UNI-E2.1 L1 L10-30 AN 47C 1342 301750 + Coupling 601023

UNI-E2.1 L1 L64 AN 47C 1342 301750 Inlet/Return 1/4 602686UNI-E2.1 L1 L64-21 AN 47C 1342 301750 Inlet/Return 1/4 602686

UNI2.1 R1 L40 UNI-E2.1 R1 L10 AN 47B 7327 301044 + Coupling 601023UNI2.1 R1 L44-21 UNI-E2.1 R1 L14 AN 47B 7327 301044UNI2.1 L5 L40-21 UNI-E2.1 L5 L10 AN 47C 1342 301750 + Coupling 601023UNI2.1 L5 L142-21 UNI-E2.1 L5 L12 AN 47C 7228 301045 + Coupling 601023UNI2.1 L5 L44-21-05 UNI-E2.1 L5 L14 AN 47C 1342 301750

UNI-E2.1 L5 L14-13 AE 47C 1387 301799UNI2.1 L5 R44-21 UNI-E2.1 L5 R14 AN 47D 1339 301749

UNI-E2.1 L5 R14-13 AE 47D 1385 301798UNI2.1 L5 R94-05 UNI-E2.1 L5 R74 AN 47D 1339 301749 Inlet/Return. 1/4 602686

UNI-E2.91 L5 L14 AN 47C 1342 301750 + kit BP 301453UNI-E2.96 L5 L14 AN 47C 1342 301750 + kit BP 301453

UNI2.1 R5 L42-UI-21 UNI-E2.1 R5 L12-80 AN 47B 7227 301043 + Coupling 601023UNI2.1 R5 L42-UI-21 UNI-E2.1 R5 L12-80 AN 47B 7217 301732 + Coupling 601023UNI2.1 R5 L44-21 UNI-E2.1 R5 L14 AN 47B 7324 301044UNI2.1 R5 L54 UNI-E2.1 R5 L24 AN 47B 1395 301049UNI2.1 R5 R44-2-051 UNI-E2.1 R5 R14 AN 47A 1326 301731UNI2.1 R5 R45-21 UNI-E2.1 R5 R15 AN 47A 7226 301042UNI2.1 R5 R80-05 UNI-E2.1 R5 R80 AN 47A 1326 301731 + 601023 + 602686UNI2.1 L6 L46 S-W UNI-E2.1 L6 L16-11 AE 67C 7285 301812UNI2.1 L6 L46-W1 UNI-E2.1 L6 L16-11 AE 67C 7285 301812UNI2.1 L6 L54-05 UNI-E2.1 L7 L24 AN 67C 1336 301065UNI2.1 R6 L25 UNI-E2.1 R6 L25 AN 67B 7287 301064UNI2.1 R6 L54-05 UNI-E2.1 R6 L24 AN 67B 1335 301074UNI2.1 L7 L55-05 UNI-E2.1 L7 L25UNI2.1 R7 L55-05 UNI-E2.1 R7 L25UNI2.1 L7 L56-S-W UNI-E2.1 L7 L26-11UNI2.1 L7 L56-W1-05 UNI-E2.1 L7 L26-11UNI2.1 L8 L56-W1-05 UNI-E2.1 L8 L26-11

Oil pump

CSB.179

Oil p

ump

PO

Page 22: Oil Pumps - Boiler Parts - Boilerparts.co.ke

REPLACEMENT TABLE for ECKERLE PUMPS by SUNTEC (continuation)

ECKERLE � SUNTECECKERLE Replacement by SUNTEC Features

Old type new type Type Ref To be added RefUNI2.13 L8 L56-S UNI-E2.13 L8 L26-11

UNI-E2.2 L1 L10 AS 47C 1538 301086 + Coupling 601023UNI2.2 L1 L14-21 UNI-E2.2 L1 L14 AS 47C 1538 301086UNI2.2 L1 L16 K1-21 UNI-E2.2 L1 L16-10 AS 47C 7434 301841UNI2.2 L1 L44 B21 UNI-E2.2 L1 L14 AS 47C 1536 301086UNI2.2 L1 R14 C1-21 UNI-E2.2 L1 R14-12 AS 47D 1539 301088UNI2.2 R1 L40 UNI-E2.2 R1 L10 AS 47B 1537 301084 + Coupling 601023UNI2.2 R1 M14-21-05 UNI-E2.2 R1 M14 AS 47B 1537 301084

UNI-E2.2 R1 S14 AS 47A 1536 301082UNI2.2 R1 R24 UNI-E2.2 R1 R24 AS 47A 1536 301082UNI2.2 L5 L14-21-05 UNI-E2.2 L5 L14 AS 47C 1538 301086

UNI2.2 L5 L14-Q-21 UNI-E2.2 L5 L14-92 AS 47C 1538 301086 replaces the sole pump of the kit

UNI2.2 L5 L15-21-05 UNI-E2.2 L5 L15 AS 47C 7438 301843UNI2.2 L5 L40-X UNI-E2.2 L5 L10-50 AS 47C 1538 301086 + Coupling 601023UNI2.2 L5 L42 UNI-E2.2 L5 L12 AS 47C 7438 301843 + Coupling 601023UNI2.2 L5 M14 C1 UNI-E2.2 L5 M14-12 AS 47C 1538 301086UNI2.2 l5 s20-21 UNI-E2.2 l5 s20 AS 47D 1557 301849UNI2.2 L5 S20-21BUD UNI-E2.2 L5 S20BUD AS 47D 1557 301849

UNI-E2.2 L5 L60 AS 47D 1538 301086 + 601023 + 602686UNI-E2.2 L5 S74 AS 47D 1550 301083 Inlet/Return 1/4 602686

UNI2.2 L5 S74-05 AS 47D 1550 301083 Inlet/Return 1/4 602686UNI2.2 R5 L14-21-05 UNI-E2.2 R5 L14 AS 47B 1537 301084

UNI-E2.2 R5 M14 AS 47B 1537 301084UNI2.2 R5 R14-21 UNI-E2.2 R5 R14 AS 47A 1536 301082UNI2.2 R5 M45 UNI-E2.2 R5 M15 AS 47B 1537 301084 + Adapter hub 32 301310UNI2.2 R5 R60-21 UNI-E2.2 R5 R60 AS 47A 1536 301082 + Coupling 601023UNI2.2 R5 r80-21 UNI-E2.2 R5 r80 AS 47A 1536 301082 + Coupling 601023

UNI-E2.2 R5 s14 AS 47A 1536 301082 + Coupling 601023UNI2.2 R5 S60 UNI-E2.2 R5 S60 AS 47A 1536 301082 + 601023 + 602686UNI2.2 R5 S60-ET UNI-E2.2 R5 S60 AS 47A 1536 301082UNI2.2 R5 S60-T-21 UNI-E2.2 R5 S60-31UNI2.2 r5 s60-t-e UNI-E2.2 R5 s60-31

UNI-E2.2 L6 L14 AS 67C 1570 301862 + 601023 + 602686UNI2.2 L6 L16-K1 UNI-E2.2 L6 L16-10 AS 67C 7456 301861 Inlet/Return 1/4 602686UNI2.2 L6 L16-W-1-0 UNI-E2.2 L6 L16-10 AS 67C 7456 301861UNI2.2 l6 l24-05 UNI-E2.2 L6 l24 AS 67C 1570 301862

UNI-E2.2 L6 R14-61 A2L65D9703 301930UNI2.2 R6 M24-05 UNI-E2.2 R6 M24 AS 67B 1575 301863UNI2.2 R6 S24-ET UNI-E2.2 R6 S24 AS 67B 1575 301863UNI2.2 R6 S24R1 UNI-E2.2 R6 S24-40 AS 67B 1575 301863 602022UNI2.2 R6 S24 R1 ET UNI-E2.2 R6 S24-40

UNI-E2.2 L7 LR14-61 A2L95D9702 301931UNI2.2 R7 L24-05 UNI-E2.2 R7 L24UNI2.2 R7 R24 R1 UNI-E2.2 R7 R24-40UNI2.2 R7 R24 R1-ET UNI-E2.2 R7 R24UNI2.2 R7 R54-05 UNI-E2.2 R7 R24UNI2.2 R7 R54-ET UNI-E2.2 R7 R24UNI2.2 R7 R56-H-ET UNI-E2.2 R7 R26UNI2.2 II L7 L26-w-01 UNI-E2.2 L7 L26 AL 95C 9412 301984 601130UNI2.3 L1 L56-I UNI-E2.3 L1 L26-80 D 45C 7389UNI2.3 L1 L56-W-05 UNI-E2.3 L1 L26-80 D 45C 7389UNI2.3 L1 R54-S-05 UNI-E2.3 L1 L224-13 D 45C 7374 301115UNI2.3 L5 L546-I UNI-E2.3 L5 L24-80 D 45C 7374 301115UNI2.3 L5 L56-W-I-05 UNI-E2.3 L5 L26-80 D 45C 7289

UNI-E2.3 L5 L64 D 45C 7374 301115UNI2.3 L5 R54-S UNI-E2.3 L5 R24-13UNI2.3 R5 R54-L54-05 UNI-E2.3 R5 L24 D 45B 7347 301114UNI2.3 R5 R54-L UNI-E2.3 R5 R24-93 D 45A 7348 301140UNI2.3 R6 L55-05 UNI-E2.3 R6 L25UNI2.4 L1 M10-V2 UNI-E2.4 L1 M10-22 AP 47C 1511 301096UNI2.4 L4 M14 C1 UNI-E L1 M14-12 AP 47C 7556 301098UNI2.4 L1 R14-C1-21 UNI-E L1 R14-12 AP 47D 9566 301941UNI2.4 L1 R44 UNI-E 2.4 L1 R14 AP2 45D 9566 301941

UNI-E 2.4 L5 L20 AP2 45C 9569 301940UNI2.4 L5 L24 UNI-E L5 L24 AP 47C 7556 301098UNI2.4 L5 M20-21 UNI-E2.4 L5 M20 AP2 45C 9569 301940UNI2.4 L5 M24 UNI-E2.4 L5 M24 AP 47C 7556 301098UNI2.4 L5 S24 UNI-E2.4 L5 S24 AT2 45D 9544 301121UNI2.42 L5 L64 65 AT2 45C 9541 301120UNI2.4 R5 L24-05 UNI-E2.4 R5 L24 AP 47B 7561 301099UNI2.4 R5 R24 UNI-E2.4 R5 R24 AP 47A 7555 301103UNI2.4 R5 S70-ET UNI-E2.4 R5 S70 AP 47A 1593 301100UNI2.4 R5.5 L24 UNI-E2.4 R5.5 L24 AP255B9567 301942UNI2.42 R5 R70 UNI-E2.42 R5 R70 AT2 45A 9547 301132UNI2.42 R5 R70-ET UNI-E2.42 R5 R70 AT2 45A 9547 301132UNI2.4 L6 L22 UNI-E2.4 L6 L22 AP 67C 7458 301107 + Coupling 601023UNI2.4 L6 L24-05 UNI-E2.4 L6 L24 AP 67C 7559 301109

Oil pump

CSB.180

Oil p

ump

PO

Page 23: Oil Pumps - Boiler Parts - Boilerparts.co.ke

REPLACEMENT TABLE for ECKERLE PUMPS by SUNTEC (continuation)ECKERLE Replacement by SUNTEC Features

Old type new type Type Ref To be added RefUNI2.4 L6 M24-C1 UNI-E2.4 L6 M24-12 AP 67C 7559 301109UNI2.4 R6 S24-ET UNI-E2.4 R6 S24 AP 67A 1594 301108UNI2.4 L7 L23 UNI-E2.4 L7 L22 AP295C9590 301943UNI2.4 L7 L24-05 UNI-E2.4 L7 L24 AP 67C 7559 301943UNI2.4 L7 L25-K UNI-E2.4 L7 L25-20UNI2.4 L7 M25 UNI-E2.4 L7 M25 AP295C9590 301943 + Adapter hub 32/54 301310

UNI-E2.4 L7 L26 AP295C9590 301943 + Adapter hub 32/54 301310UNI2.4 L7 L26-05 UNI-E2.4 L7 L26-05 AP295C9590 301943 + Adapter hub 32/54 301310UNI2.4 L7 L56 UNI-E2.4 L7 L26UNI2.4 R7 R54-05 UNI-E2.4 R7 R24

UNI-E2.6 L5 L14 AN 47C 1342 301750 Change in one pipeUNI2.6 L6 L44 UNI-E2.6 L6 L44 AN 67C 1336 301065 Change in one pipeUNI2.7 R5 R44 UNI-E2.7 R5 R14UNI2.91 L5 L44 UNI-E2.91 L5 L14 AN 47C 1342 301750 + low pressure kit 991 301453UNI2.91 L7 L44-05 UNI-E2.91 L7 L14 AE 97C 7390 301839UNI2.91 R7 L44-05 UNI-E2.91 R7 L14UNI2.93 L1 R44-05 UNI-E2.93 1 R14UNI2.96 L5 L44-05 UNI-E2.96 L5 L14 AN 47C 1342 301750 + low pressure kit 991 301453UNI2.96 L7 L44 UNI-E2.96 L7 L14 (old)

UNI-E2.4 L7 L24UNI-E2.4 L7 L26-05UNI-E2.6 R1 L44UNI-E2.6 L5 L40UNI-E2.6 L5 L84UNI-E2.6 R5 L42UNI-E2.6 L6 L14

ECKERLE PUMP ACCESSORIESSHAFT SEAL

Description Mark RefShaft seal for type UNI 2 new type (lip seal) and UNI 1 1 302223Shaft seal for type BP1 - UNI 1 - UNI 2 old type left rotation 2 302222

COVER GASKETDescription Ref

COVER GASKETfor BP1 type 302210for UNI 2 type 302212for UNI 1 type 302213

STRAINERDescription Ref

STRAINERfor UNI 2 type (up to 1978)) 302202

RIELLO PUMPWith or without SOLENOID VALVE

TypeFlow l/h

to 2800 tr/mnand 10 bars

Adjusting pres-sure bar hub Ø Ø and lg of shaft Rotation Ref

300.7480 (1) (f) 38* 8 to 15 Ø 32 8x14 � 404660300.7771 (e) 38 5 to 14 Ø 32 8x14 � 404264

(1) For Gulliver BG1(*) Outlet nozzle on the right(e) For Gulliver RG0 (358T1 - 359T1 - 360T1) - RG1 (363T1) - RG2 (377T1) - No coil.(f) For Gulliver RG1 (362T1 - 36305T1 - 364T1) - RG2 (37711T1) - BG1 (371T1) - BG2 (372T1) - BG3 (373T1) - No coil.

TypeFlow l/h

to 2800 tr/mnand 10 bars

Adjusting pres-sure bar hub Ø Ø and lg of shaft Rotation Ref

300.7337 (3) 38 5 to 14 Ø 32 8x14 � 404263300.5705 (1) 38 5 to 14 Ø 32 8x14 � 404263300.7339 (2) 38* 8 to 15 Ø 32 8x14 � 404263300.7800 (d) 38* 8 to 15 Ø 32 8x14 � 404263300.7807 (g) 38* 5 to 14 Ø 32 8x14 � 404865

(1) Hub extended pump shaft - Plunger without coil.(2) Same (1) but progressive regulator.(3) For burner G5RK - (*) Outlet nozzle on the right(d) For range Mectron 2 to15 and 40G2 - No coil (replaces 3007337 and 3006705).(g) For range Mectron 20 and 40G20S (replaces 3007339 and 3005821).

1

2

Oil pump

CSB.181

Oil p

ump

PO

Page 24: Oil Pumps - Boiler Parts - Boilerparts.co.ke

RIELLO PUMP (continuation)

With or without SOLENOID VALVE

TypeFlow l/h

to 2800 tr/mnand 10 bars

Adjusting pres-sure bar hub Ø Ø and lg of shaft Rotation Ref

300.5353 (b) 72 5 to 14 Ø 32 8x14 � 404261(b) For Press GV - GW /(c) For Press 1G - 2G

TypeFlow l/h

to 2800 tr/mnand 10 bars

Adjusting pres-sure bar hub Ø Ø and lg of shaft Rotation Ref

300.2543 - - - - - 404267300.2495 - - - - - 404266

RIELLO PUMP ACCESSORIESRIELLO PUMP COIL

Description RefCoil ref. 3002279 for pump 404865 and 404263 404859Coil ref. 3007481 for pump 404660 404853Coil ref. 3007565 for pump 404264 404852

RIELLO PUMP SOLENOID PLUNGER

Description RefSolenoid plunger ref.3006925 for pump 404865 - 404263 - 404660 404858Solenoid plunger ref.3007582 for pump 404264 404851

RIELLO PUMP STRAINER

Description RefStrainer for pump ref. 3005719 404162

RIELLO PUMP SHAFT SEAL

Description RefShaft seal ref. 3000439 all type of pump 404168

RIELLO PUMP O’RING

Description Mark RefO’ring type 3007028 for pressure screw 1 404165Cover gasket for remote shaft pump 3007152 2 404167O’ring ref .3007162 for new pump 2 404849

SAFAG PUMPNVBR Range

Type

While odering, please specify Flange 92 mmØ

Inlet/return.

Pressure Range

BarRotation RefFlow l/h

to 1400 tr/mnand 10 bars

Flow l/hto 2500 tr/mn

and 10 bars

Ø hub and shaft in mm

NVBR-PDC 45 90 Ø 54x12 12x17 8 to 30 � 306192

Shaft seal 180°

1

2

x 12x 12x 10

Oil pump

CSB.182

Oil p

ump

PO

Page 25: Oil Pumps - Boiler Parts - Boilerparts.co.ke

NVBGR Range

Type

While odering, please specify Flange 92 mmInlet/return

Ø

Pressure Range

BarRotation RefFlow l/h

to 1400 tr/mnand 10 bars

Flow l/hto 2500 tr/mn

and 10 bars

hub and shaft Ø in mm

NVBGR-GIC 600 - Ø 54x12 15x21 8 to 30 306035Shaft seal 180° Note : No by-pass plug

VBH Range

Type

While odering, please specify Flange 92 mmInlet/return

Ø

Pressure Range

BarRotation RefFlow l/h

to 1400 tr/mnand 10 bars

Flow l/hto 2500 tr/mn

and 10 bars

hub and shaft Ø in mm

VBH-PDC Baltur - - - - - 431239VBH-GDC Baltur - - - - - 431240VBH-PDC Baltur - - - - - 431249

Shaft seal 180°Note : No by-pass plug

SP PUMPSP 66-68 Range

Low burner capacity pump

TypeFlow l/h to 2800

tr/mnand 10 bars

Ø=Hub and shaft in mm Rotation Solenoid valve Ref

SP 660228 12 28x6 � without 307010SP 660218 without 307011SP 680218 without 307021

SP PUMP ACCESSORIESSTRAINER KIT - STRAINER - DIAPHGRAM - ADAPTER HUB - COUPLING

Description Mark RefStrainer kit Tray 1 307100Strainer 2 307110Diaphragm 3 307120Coupling 4 307140

SOLENOID VALVELUCIFER Normally closed NF

Type Thread Entraxe height in mm

Differential pressure bar Voltage Ref

121 K 63Normally closed - KV value 3,5l/mn - coil 14W

F1/4 40x78 0,3220V 109050380V 109060

122 K 8363Normally open - KV value 4,3l/mn - coil 14W

F1/4 40x78 0,3 220V 109051Description Ref

220V AC Spare coil 481044 - 14 watts 109068380V AC Spare coil 481044 - 14 watts 109069

1 2

34

Oil pump

CSB.183

Oil p

ump

PO

Page 26: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SOLENOID VALVERAPA Normally closed NF

Used on fuel oil burners - Pressure drop 2 bars, capacity burner maxi 1.000.000K/cal.Used by Oertli SGB - Cuenod - Elco - Diemo - Mazeco - Geminox - Mat Klockner - Zaegel Held. Replaces VE131X SCEM.Supplied for 220V AC with connector.Supplied for 110V AC without connector

Type Pressure bar KV values (liter/mn) Thread Entraxe / Height Voltage Fluid Temp. Ref

BV01 24 1,4 FxF1/8 32x65 220 0/+60 109000BV01 loose piece 109002BV01 24 1,4 FxF1/8 32x65 110 0/+60 109001BV01 24 1,4 FxF1/4 34x65 220 0/+60 109011

Description Mark RefConnector with cable lg 400 mm 1 803030Connector with cable lg 800 mm 1 803029Compound DIN Connector 1 803034Pluggable DIN Connector 1 105435110V AC Spare coil 2 109016380V AC Spare coil 2 10901712V DC Spare coil 2 10901824V AC Spare coil 2 109075

BRAHMA Normally closed NF

Solenoid valve for fuel oil pipe cut-off functionSupplied with 220V AC coil and connector.

Type Pressure bar Thread Entraxe /height Voltage Packaging RefE7 20 MxF 1/8 30x73 220 109008

Description RefDIN Spare connector 105435220V AC Spare coil 109089

SCEM Normally closed NF

Type Pressure bar Thread Entraxe /height Voltage Packaging RefPM140CR 17 FxF 1/4 40x80 220 109009

Description RefSpare connector 105435220V AC Spare coil 406332

SPECIFIC SOLENOID VALVESOLENOID VALVE for NOZZLE LINE

Description Mark RefCUENOD Solenoid valve coil on C4 / C6E burner 1 406332GIANOLASolenoid valve coil on VIZIR burner 2 109000JOANNES Solenoid valve coil on AZ 18 burner 3 409315BALTURSolenoid valve coil on BT120 DSG burner - 431169

FUEL HOSE - NIPPLE for NOZZLE LINEDescription Mark Ref

Fuel hose in black rubber L 450mm - Inside 3 mm - live female 1/8" (5x10) other side 90° angled live female 1/8 1 602022Nipples M1/8 x 1/8 conical 2 602783

STANDARD FUEL OIL PIPE KITKit composed of : ✓copper tube (lg 0,50m) ✓male nipple 1/8 for pump outlet nozzle ✓female nipple 1/8 for nozzle assembly ✓male conical nipple 1/8

Description RefStandard fuel oil pipe kit 602028

1

2

12

3

1

2

x 6x 6x 1

x 1

x 1

CSB.184

Oil p

ump

• Tr

ansf

er p

ump

PO

Oil pump • Transfer pump

Page 27: Oil Pumps - Boiler Parts - Boilerparts.co.ke

LOW PRESSURE FUEL OIL MOTORPUMPfor DOMESTIC FUEL OILadjusting pressure 0,5 to 3 bars - two-pipe pump

USED :Suction height maxi 4mSuction length maxi 8mThis motorpump is used for boiler installations far from the fuel tank. This motorpump must be installed near to the fuel tank and plugged with the burner starter. Used in one-pipe or two-pipe installations. For one-pipe installation you must know the nozzle capacity to select the fuel oil motorpump (select a motorpump flow with 50% higher than nozzle flow). For two-pipe installation you must know the burner pump flow to select a fuel oil motorpump (select a motorpump flow with 25% to 50% higher than burner pump flow)

Type Flow 1bar 5cst Motor 220 V mono Threads Installation RefInlet Return

MB0057BP 60l/h 130W 2800tr/mn 1/4” 1/4”2-3-4-5-6 309001

MB0067BP 90l/h 130W 2800tr/mn 1/4” 1/4” 309006

adjusting pressure 0,5 to 3 bars - one-pipe pump

USED :Suction height maxi 4 mSuction length maxi 8 mThese motorpumps allow feeding boilers : ✓Directly. ✓With fuel oil tank. ✓In a fuel oil supply closed circuit. The fuel oil excess flow returns to the inlet pump through a by-pass inside the pump.This motorpump must be installed near to the fuel tank (Suction length maximum 8 meters - Suction height 4 meters maximum with 8mm Ø)

Type Flow 1bar 5cst Motor 220 V mono Threads Installation RefInlet Return

ECO BP 50 55l/h 130W 2800tr/mn 1/4” 1/4”6-8-9 309002

ECO BP 140 145l/h 130W 2800tr/mn 1/4” 1/4” 309003

adjusting pressure 0,5 to 3 bars - two-pipe pump

USED :Suction height maxi 4mSuction length maxi 8mThis motorpump is used for boiler installations far from the fuel tank. This motorpump must be installed near to the fuel tank and plugged with the burner starter. Used in one-pipe or two-pipe installations. For one-pipe installation you must know the nozzle capacity to select the fuel oil motorpump (select a motorpump flow with 50% higher than nozzle flow). For two-pipe installation you must know the burner pump flow to select a fuel oil motorpump (select a motorpump flow with 25% to 50% higher than burner pump flow).

Type Flow 1bar 5cst Motor 220 V mono Threads Installation RefInlet Return

GEPA J4 BP 130l/h 180W 2800tr/mn 1/4” 1/4”3-4-5-6 309081

GEPA J6 BP 230l/h 240W 2800tr/mn 1/4” 1/4” 309041

adjusting pressure 0,5 to 3 bars - two-pipe pump

USED :(Same as GEPA)

Type Flow 1bar 5cst Motor 220 V mono Threads Installation RefInlet Return

GAPA J4 BP 130l/h 240W 2800tr/mn 1/4” 1/4”2-3-4-5-6 309082

GAPA J6 BP 230l/h 240W 2800tr/mn 1/4” 1/4” 309042

Transfer pump

CSB.185

Tran

sfer

pum

pP

O

Page 28: Oil Pumps - Boiler Parts - Boilerparts.co.ke

LOW PRESSURE FUEL OIL MOTORPUMP FOR DOMESTIC FUEL OIL (continuation)

NOTEINSTALLATION : You must check that if the rotation direction of the motor and the rotation direction of the pump are the same.Bleeding in two-pipe operation is automatic. In one-pipe operation the plug of a pressure gauge port must be loosened until the air is evacuated from the system.

ADJUSTING PRESSURE : Screw in the right clockwise rotation to increase the pressure and in the left clockwise rotation to decrease.

with tank and level control CASE Pump for MB motorpump

A : Inlet 1/4"G : Outlet nozzle 1/8"R : Return 1/4"P : Pressure gauge port 1/8"V : Vacuum gauge port 1/8"Z : Adjusting pressure screw.

In this case you must install a filter on the suction pipe ref 903462See Motorpump accessories

with tank return CASE 4

INSTALLATION : You must prime the suction circuit before starting the motorpump.with tank and level control CASE 2

Two-pipe installation with T nipple on return. Two-pipe filter ref 903460. It is recommended to equip the motorpump suction pipe with a filter ref 603010See motorpump accessories

In this case you must install a filter on the suction pipe ref 903462. It is recommended to equip the motorpump suction pipe with a filter ref 603010See motorpump accessories.

Without tank return CASE 5

INSTALLATION : You must prime the suction circuit before starting the motorpump.

without tank and level control CASE 3

Return plugged and by-pass plug removed. Two-pipe filter diff ref 903460. It is recommended to equip the motorpump suction pipe with a filter ref 603010

See motorpump accessories. Pump GEPAJ motorpump A : Inlet 1/4" G : Outlet nozzle 1/8" R : Return 1/4" P : Pressure gauge port 1/8" V : Vacuum gauge port 1/8" Z : Adjusting pressure screwOne-pipe installation with filter ref 903462. It is recommended to equip the motorpump suction pipe with a filter ref 603010 See Motorpump accessories.

2/ Low pressure fuel oil motorpump

5/ Low pressure fuel oil motorpump

3/ Low pressure fuel oil motorpump

6/ Low pressure fuel oil motorpump

4/ Low pressure fuel oil motorpump

Transfer pump

CSB.186

Tran

sfer

pum

pP

O

Page 29: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SELF PRIMING MOTORPUMP for DOMESTIC FUEL OILUSED :Maxi suction height 4 mMaxi suction length 8 m(recommended height and lenght to avoid fuel oil emulsion)Possible maxi suction height 9m (except CAM 60 limited 6,5m)This motorpump is used for boilers installations far from the fuel tank. This motorpump must be installed near to the fuel tank and plugged with the burner starter. Used in one-pipe or two-pipe installations. For one-pipe installation you must know the nozzle capacity to select the fuel oil motorpump (select a motorpump flow with 50% higher than nozzle flow). For two-pipe ins-tallation you must know the burner pump flow to select a fuel oil motorpump (select a motorpump flow with 25% to 50% higher than burner pump flow).

Type l/h

Height Motor 2800 tr Threads FxF

Installation RefSuction pipe and Pressure

pipe combinedCV Voltage Inlet Return

CAM 60 750120

6,520 0,2 220 single

phase 1/2" 1/2"

8 and 9

309490

CAM 80 1900380

1536 0,5 220 single

phase 3/4" 3/4" 309491

CAM 90 2400480

1742 0,75 220 single

phase 1" 1" 309492

CA 91 2400600

1751 1 220/380

three phase 1" 1" 309493

CAM 80 1900380

1536 0,5 220/380

three phase 3/4" 3/4" 309494

FILTER for :CAM 60 and 80 Diff ref 603258CAM 90 and CA 91 Diff ref 603260

NOTE :Motorpump CAM can be used for draining tank sludge but only liquid sludge (diluted sludge and no hard particule). - When the draining is finished you must take the water off the body pump and fill the pump with oil or fuel to avoid the rust. - Before you start to drain the tank you must turn the motor with a screwdriver (hand operated) to prevent any gripping

HIGH PRESSURE FUEL OIL MOTORPUMP FOR DOMESTIC FUEL OILAdjusting pressure 10 to 20 bars

USED :Maxi suction height 4 m - Maxi suction length 8 mThis motorpump is used for boilers installations far from the fuel tank. This motorpump must be installed near to the fuel tank and plugged with the burner starter. Used in one-pipe or two-pipe installations. For one-pipe installation you must know the nozzle capacity to select the fuel oil motorpump (select a motorpump flow with 50% higher than nozzle flow). For two-pipe ins-tallation you must know the burner pump flow for select a fuel oil motorpump (select a motorpump flow with 25% to 50% higher than burner pump flow).

Type Flow 7bars 5cst Motor 220/380 V tri

ThreadsInstallation RefInlet Return

GEP J 728 350l/h 370W 2800tr/mn 1/2” 1/2”7-8-9

309050GEP J 714 160l/h 370W 1400tr/mn 1/2” 1/2” 309061

USED :

Same as GEP

Type Flow 7bars 5cst Motor 220/380 V tri

ThreadsInstallation RefInlet Return

BT2 550 1300l/h 750W 2800tr/mn 3/4” 3/4”7-8-9

on requestBT3 750 1950l/h 750W 1400tr/mn 3/4” 3/4” on request

Burner return with recirculation filter - 1 burner Recirculation filter

One-pipe installation with pressure regulator ref 309240 and One-pipe installation with adjusting pressure valve and recirculation filter recirculation filter ref 903462 ref 903462See Motorpump accessories See Motorpump accessories

7/ High pressure fuel oil motorpump 8/ High pressure fuel oil motorpump

Transfer pump

CSB.187

Tran

sfer

pum

pP

O

Page 30: Oil Pumps - Boiler Parts - Boilerparts.co.ke

HIGH PRESSURE FUEL OIL MOTORPUMP FOR DOMESTIC FUEL OIL (continuation)

Pump for GEP J/E motorpump

A : Inlet 1/2" Z : Outlet nozzle 1/4" High flow R : Return 1/2" P : Pressure gauge 1/8" G : Adjusting pressure

Closed circuit installation with adjusting pressure valve ref 309209 See Motorpump accessories.

1. Starting a pumpWhen the installation is finished you must bleed the pipe, the filter, and the pump and fill in with oil (the pump must not operate without fuel oil to avoid shaft seal damage). - Connect a vacuum gauge to the pump vacuum port. - Connect the priming DIFF pump Ref 901570 to the pressure gauge port and draw up the fuel oil through the oil pump burner. If this is the burner pump you can short-circuit the burner photocell. Start the burner or the motorpump and unscrew the pressure gauge port during 2 to 5 mn, until the fuel bubbles disappear. - The vacuum lift indication must be equal to 0,4 bar maximum. If the vacuum lift indication is more than 0,4 bar and if the length and height suction pipe are in accordance with the manufacturer values, check the pipe for searching a plugged filter, then retry.

2. Checking for leaks in fuel oil suction pipeThis test is made to detect air intakes or plugged suction pipe. - Disconnect the suction pipe nearest to the fuel tank. - In two-pipe installation you must disconnect the return pipe on the pump and plug the pump return. - Connect a pressure gauge to the pump pressure gauge port. - Pressurize the fuel oil suction pipe to 0,7 bar (dot not exceed 2 bars). - If the pressure gauge indication falls there is a leak in the system. - Check for leaks in the fittings. - Check for leaks in the plugs and the filters.

3. Pump maintenance - Check the filter neatness and change it if necessary. - Change the cover gasket.

4. Cases of failures - a) Air intakes make noise, unstable pressure and no cut-off to the nozzle. - b) Plugged pipes or unscrewed fittings make noise, fuel leaks and no cut-off to the nozzle. - c) Water oxidizes the pump gear.

FUEL OIL TRANSFER MOTORPUMP WITH MANUAL NOZZLE AND ACCESSORIESKIT MIDI

Type l/hHeight Motor 2800 tr Ø Thread FxF

Ref(1) Vacuum lift

in m CV Voltage Inlet Return

KIT MIDI 2280 35 6 0,5 220 single phase 1" 1" 309280 (1) Lift in meter

Supplied with cable : � Switch on/off � 4 meters flexible rubber hose � Manual nozzle and check valve with filter � Not supplied suction pipe

Description RefBP 55 Pump 309290Manual nozzle Self 2000 aluminium 309291hose Ø 25 (meter price - lenght on request) 309292End hose terminal for tube 1" x Ø 25 309294Inox clamp for end hose 309295Check valve and fi lter 309293

FUEL OIL MOTORPUMP ACCESSORIESMECHANICAL FUEL METER type K33

APPLICATIONS :Possible installation directly in the outlet motorpump kit midi Diff ref 309280 with male 1“ nipple. � Nutating-disk meter that measures the exact quantity of the dispensed fuel. � Easy reading. � 4 possible connections (horizontal and vertical). � Cold resistance -35°C. � Allows to work with gravity feed pump (SP32 or BM type).

Manufacture : � Built with aluminium and polybutile � Readout system : up to 999 l by delivery; Total delivery up to 100 000 l. � Maxi operating pressure : 3,5 bars � Standard measure : in liters � Flow rate : 20 to 120 liters/mn. � Temperature : -10°C +60°C � Fittings threaded 1 BSP female � Weight : 1,8 kg � Entraxe : 175 mm � Accuracy : ± 1%100 000 l.

Description RefMechanical fuel meter K33 309281

9/ High pressure fuel oil motorpump

USE

Transfer pump

CSB.188

Tran

sfer

pum

pP

O

Page 31: Oil Pumps - Boiler Parts - Boilerparts.co.ke

TANK AND CONTROL LEVELDescription Ref

Tank 29 liters without control level 704508

� Tank : - Height 400 mm - Length 500 mm - Width 180 mm

FILTER

Description Mark RefTwo-pipe fi lter 3/8" for burner suction pipe 1 903467Recirculation fi lter 3/8" for burner suction pipe 2 903462One-pipe fi lter 3/8" for motorpump suction pipe 3 603010

FUEL OIL HOSE

Description RefFUEL OIL HOSE for motorpump inlet and return connection MB-GEPA and GAPA - lg 0,75m 602000FUEL OIL HOSE for motorpump inlet and return connection GEPJ and GEPE - lg 0,75m 602010

ADJUSTING PRESSURE FUEL VALVE - PRESSURE REDUCER

Description Mark RefADJUSTING PRESSURE FUEL VALVE 0,5 to 3 bars threaded 15/21 Ø - Flow 8l/mn to 0,5 bar 1 309210ADJUSTING PRESSURE FUEL VALVE 0,5 to 3 bars threaded 26/34 Ø - Flow 11,9l/mn to 0,5 bar 1 309209ADJUSTING PRESSURE REDUCER 0,5 to 3 bars supplied with manometer and fi tting 1/2 to 3/4" Ø 2 309240FIXED PRESSURE REDUCER 15l/h to 100 mbars - Inlet pressure 0,5 to 6 bars - Conical nipple connection 8mm Ø 3, 309245

ADJUSTING PRESSURE FUEL VALVETV VALVE SECTION

APPLICATION : � For flow up to 5000 l/h. � Can be used with oil pump type T.WORKING : � Pressure fuel oil comes into the valve. � Pressure can be adjusted by adjusting screw. � The fuel overflow is by passed to the return.

Description RefValve TV 1001 adjusting 2 to 7 bars - Threaded 3/4 Ø 309211Valve TV 4001 adjusting 7 to 40 bars - Threaded 3/4 Ø 309212

12

3

2

3

1

Inlet Return

OutletScrew pressure

x 2x 2

Transfer pump

CSB.189

Tran

sfer

pum

pP

O

Page 32: Oil Pumps - Boiler Parts - Boilerparts.co.ke

BM346 - BM347 FUEL OIL LIFTER PUMPS and ACCESSORIES (continuation)

1 2 3 4 5 6

Description Mark RefFilter and gasket 1 309330Spare pump 2 309306Coupling (BM 346) 3 309307Coupling (BM 347) 3 309308Microswitch 4 309309Filter cover cap 5 309331Suction valve 6 309332

FUEL OIL LIFTER PUMP INSTALLATION

SP32 ACCESSORIES (old device)

1 2 3 Description Mark Ref

Coil 1 309320Filter 2 309323Plunger 3 309321Suction valve (ref.187711) - 309327Printed circuit (old type ref.187471) - 309328

1 Pump2 Burner

Suctionpump

CSB.190

Suct

ionp

ump

PO

Page 33: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SUCTION PUMPOnce again DIFF associates its name to famous brands. It was essential that DIFF could offer to its partners a well known range of pressure/suction pumps.

All the GOTEC / ECKERLE pumps are of very good quality and reliable for the users and for the installers.Each pump has its own feature, that is why we suggest a summary table.

ECKERLE SP32-01 suction pump aggregate

With electromagnetic piston pump, fl oat-, control- and safety device, built-in suction fi lter, check valve, 1,6l oil storage tank, LCD display with permanent function-control feedback, built-in safety oil pan with separate detection, thermical safety detection, pipe connections for 8x1 mm Ø, completely wired with earthing contact-type plug.

APPLICATIONS : � Pump aggregate for fan burner up to 80 kW at 7 m suction height. � Oil / tiled oven � Only for one-line systems

TECHNICAL DATA : � Electrical spec. : 230V/50-60 Hz, 25VA � Suction rate : max 8 l/h at 7 m suction height or max 18 l/h at 4 m suction height � Size (LxWxH) 285x217x168 mm � Weight : 2 kg Integrated check valve in the suction line!

TypeELECTRIC HYDRAULICS MECHANICS

RefVoltage Frequency Power Fuse Output function of suction height

Contents tank

Net weight

SP32-01 230V 50Hz 40W 0,5A7m4m

12 l/h18 l/h

1,6l 2 kg 309300

KD 10 type with accumulator

With electromagnetic piston pump, control and safety device depending on the delivery length, pressure gauge, built-in suction fi lter, pipe connections 8x1 mm Ø, completely wired with earthing contact-type plug and mounting strip.Built-in safety oil pan with separate detection!

APPLICATIONS : � Central oil distribution systems upto 12 users, suitable for full-years operation (e.g. feeding pump for oil burners in one-line systems).

TECHNICALS DATA : � Electrical spec. : 230V/50-60 Hz, 25 VA � Delivery rate : max 14 l/h at 14m delivery height, pax 3 m of suction height � Accumulator volume : 0,3l � Size : (LxWxH) : 280 x 180 x150 mm � Weight : 4kg Integrated check valve in the suction line!

ELECTRIC HYDRAULICS MECHANICS

RefVoltage Frequency PowerProtec-

tionaccording

to DIN

Fuse maxifl ow

with maxi delivery height

and maxi suction height

Pressure of adjust-

ment

G1/8“ connectors for tubes

Netweight

V Hz W A l/h m m bar

230 50 40 IP 44 0,5 12 14 3Mini 1,4Maxi 1,9

D 6/8 4,15 309318

Suctionpump

CSB.191

Suct

ionp

ump

PO

Page 34: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SUCTION PUMP (continuation)

SK9E /FP8E Type With electromagnetic piston pump, for different fl ow rates adjustable, self regulating pressure control, pressure relief valve, safety oil chamber, bleed & drain valve, built-in suction fi lter, completely wired with earthing contact-type plug and mounting strip. Tube connection 8x1 mm Ø. The unit can be used for different applications by changing the position of a jumper on the pump’s PCB.

SK9E : Pump doesn’t restart automatically in case of power failure (only for oil oven applications) -> delivery status.FP8E : For use only as a feeder pump with in control circuits (e.g. for pressure atomiser oil burners).

APPLICATIONS : SK9 Version : Central oil distribution systems with one or more oil ovens to be used as a permanent operating pump during the heating season (not usable for full-year operation). FP8E Version : Feeding pump for oil burners in one-line systems or automatic oil evaporation burners (e.g. for tiled stoves).

TECHNICAL DATA : � Electrical spec. : 230V/50-60 Hz, 25 W � Delivery rate : 3to 10l/h at 14m delivery height, pax 3 m of suction height � Accumulator volume : 0,3l � Size : (LxWxH) : 280 x 180 x150 mm � Weight : 1,8kg Integrated check valve in the suction line!

Speed slectionFunction selection

ELECTRIC HYDRAULICS MECHANICS

RefVoltage Frequency PowerProtec-

tionaccording

to DIN

Fuse maxifl ow

with maxi delivery height

and maxi suction height

Pressure of adjust-

ment

G1/8“ connectors for tubes

Netweight

V Hz W A l/h m m bar230 50 25 IP 44 0,5 10 14 3 2 D 6/8 1,8 309319

SUCTION PRESSURE AGGREGATESP 32-02-80 type

With electromagnetic piston pump, fl oat-, control- and safety device, built-in suction fi lter, 8 l oil storage tank, built-in safety oil pan with separate detection, LCD display with permanent function-control feedback with anti-syphoning protection valve, alterna-tively in mechanical version M (adjusted at 1,80m) or electrical version E (is driven through the oil burner), pipe connections for 10x1mm Ø pipe, completely wired with earthing contact-type plug.

SP32/02-80-M with mechanical anti-syphoning valveSP32/02-80-E with electrical anti-syphoning valve

APPLICATION : � Full-automatic suction pump aggregate for feeding oil burners up to max 50 l/h nozzle capacity. � Only for one-line systems

TECHNICAL DATA : � Electrical spec. : 230V/50 − 80W � Suction rate : max 60 l/h at 4m suction height � Size : (LxWxH) : 315 x 380 x 325 mm � Weight : 7 kg � Version SP 32/02-80 � Delivery rate : max 80 l/h at 4m suction height or max 25 l/h at 6m suction height

Integrated check valve in the suction line!

TypeELECTRIC HYDRAULICS MECHANICS

RefVoltage Frequency Power Fuse Suction rate Tank Net

weight

SP32-02-80-M 230V 50 HZ 80W 0,5A7m4m

20 l/h55 l/h

7,3 l 7 kg 309313

SP32-02-80-E 230V 50 HZ 80W 0,5A7m4m

20 l/h55 l/h

7,3 l 7 kg 309314

Suctionpump

CSB.192

Suct

ionp

ump

PO

Page 35: Oil Pumps - Boiler Parts - Boilerparts.co.ke

OIL SUCTION TRANSFER UNIT GPS-10

Type Suction rate(8mm l.D. tube)

Tankcapacity

Electrical specifi cation

Overfl ow outlet

connec-tion

Suction Burneroutput Size Weight Ref

Suction solenoid pump

8 liters at 8m suc-tion height or 25 m suction lenght

3,5 litersAC230V

50Hz1/2“ 3/8“ 3/8“

240x125x300

3 kg 309336

Suction solenoid pump

8 liters at 8m suc-tion height or 25 m suction lenght

12 litersAC230V

50Hz1/2“ 3/8“ 3/8“

350x225x345

4 kg 309337

Drip tray + infrared leakage detection + overfl ow sensor (40 cm)

Description RefDRIP TRAY for GPS10 suction pump 309338

DIAGRAMS for suction pump aggregate

Suctionpump

CSB.193

Suct

ionp

ump

PO

Page 36: Oil Pumps - Boiler Parts - Boilerparts.co.ke

SUCTION / EXHAUST PUMPPO 140 PUMP

Pump relay, being used to feed one or more burners with pulverization placed at different levels. A pressure reducer must be placed before the burner to protect the shaft seal against an excessive pressure. In this case, when the burner stops, the pump remains under tension, but does not supply

Type Voltage Power Maxi suctionheight in m

Flows en l/h Installation Ref

PO 140 220 27 3

20 for 20m of slope 6/8 tube

necessary 30933550 for 10m of slope

PF 350 Standard HANDLE PUMP

Handle pump designed for fuel oil transfer from tank to can. With automatic valve for retaining fuel oil after use.It is necessary to prime it at first start.Flow 15 l/mn. PF 350 supplied with a suction pipe hose 1,4m long 18mm Ø and a pressure hose 1,5m long 15mm Ø, with lip and hook.

Description RefPF 350 pump 309315

PRIMING PUMPThe priming pump transfers the tank oil to the burner before starting burner. The priming pump avoids starting when the burner pump is empty. DESCRIPTIONManual plunger with double head.Rubber head, fuel oil resistant, fi ts 8 to 18 mm pipes. A valve prevents the return of fuel oil.The bleed valve allows transfers without taking off the priming pump from the pipe end.

TECHNICAL FEATURES : � Flow : 250 cm3 � Diameter : 40 mm � Empty : 0.8 bar � Weight : 490 g � Total length : 360 mm

Description RefFuel Priming pump 901570

CARBURETTOR and ACCESSORIESCC CARBURETTOR

FLEXATEMPIncorporates an auxilary microswitch designed to control the carburettor flow with a room thermostat. With thermostat and flexatemp the oil stove works automatically .

Description Mark Ref240 VR Flow in cc/mn 40/7 1 412013

FLEXATEMP 220V - 12 Watts 2 412040Filter for carburettor CC 240VR 3 411060

SPARE PARTS -Filter plate 240 VR - 412031Filter plate screw - 412032

BM CARBURETTORTEMPOMATIncorporates an auxilary microswitch designed to control the carburettor flow with a room thermostat. With thermostat and Tempomat the oil stove works automatically. Fuel stove carburettor. Threaded 1/4 NPT. Standard size, replaces many current marks

Description Mark Reftype 30 Flow in cc/mn 5 to 50 (can replace 412018) 1 412024

Description Mark RefFilter for carburettor 2 412026

1

2

3

1

2

Suctionpump

CSB.194

Suct

ionp

ump

PO

Page 37: Oil Pumps - Boiler Parts - Boilerparts.co.ke

TOBY CARBURETTOR

Description Mark RefType 11.746 Flow 3 to 13 cc/mn 1 412044Type 11.550 Flow 4 to 17 cc/mn 1 412045Type 11.487 Flow 5 to 19 cc/mn 1 412046Type 11.755 Flow 7 to 26 cc/mn 1 412047Type 09.967 Flow 11 to 48 cc/mn 1 412048Type 10.545 Flow 13 to 62 cc/mn 1 412049

Filter with gasket 2 412041

TOBY carburettor auxiliary relay ref 9231 works with room thermostat (DEVILLE generator (9256A-9266A))

TOBY DVR5 CARBURETTORDescription Ref

Type 521128 Flow 2,8 to 9,6 cc/mn 412060Type 521135 Flow 3,5 to 12,5 cc/mn 412061Type 522139 Flow 3,9 to 12,4 cc/mn 412062Type 522155 Flow 5,5 to 16,2 cc/mn 412063Type 522173 Flow 7,3 to 23 cc/mn 412064Type 5211D100 Flow 4 to 17 cc/mn 412065Type 5211D100 Flow 4,5 to 15 cc/mn 412066

TOBY DVR5 carburettor incorporated in fuel cooker ROSIERES and SUPRA..

CARBURETTOR POWER TABLEminimum Flow Power

mini Kw/hPower

in thermieminimum Flow Power

Kw/hPower

in thermiecc/mn l/h cc/mn l/h3 0.18 1.87 1.62 18 1.08 11.32 9.804 0.24 2.50 2.16 20 1.20 12.48 10.80

4.5 0.27 2.81 2.43 22 1.32 13.73 11.885 0.30 3.12 2.70 24 1.44 14..98 12.966 0.36 3.74 3.25 26 1.56 16.22 14.047 0.42 4.37 3.78 28 1.68 17.47 15.128 0.48 4.99 4.31 30 1.80 18.72 16.209 0.54 5.62 4.86 32 1.92 19.97 17.2810 0.60 6.24 5.40 34 2.04 21.22 18.3612 0.72 7.49 6.48 36 2.16 22.46 19.4413 0.78 8.11 7.02 38 2.28 23.71 20.5214 0.84 8.74 7.56 40 2.40 24.96 21.6015 0.90 9.36 8.10 44 2.64 27.46 23.7616 0.96 9.98 8.64 50 3.00 31.20 27.0017 1.02 10.61 9.18 55 3.30 34.32 29.70

Note : 1 Th (thermie) = 10 000 K / calories 1 Kw/h = 864 K / calorie

STONE HEATING

GENERATOR and STOVE IGNITOR

Description RefFor GRETAL 630 -15 27x140 mm Ø 441300For GREMA and GREMIA 630 -12 27x94 mm Ø 441301For SILENTA 630 -17 27x95 mm Ø (+electrode) 441302

1

2

Suctionpump / Carburettor

CSB.195

PO

Suct

ionp

ump

• Ca

rbur

etto

r

Page 38: Oil Pumps - Boiler Parts - Boilerparts.co.ke

Note :

CSB.196

Carb

uret

tor

PO