October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

34
October, 2012 Page 1 of 2 Carrier Software Systems Syracuse, NY, USA 1-800-253-1794 [email protected] Carrier Electronic Catalog Customer Suite Version 20121005 Release Sheet Carrier Electronic Catalog Customer Suite v20121005 replaces v20120907 SOFTWARE DESCRIPTION The Carrier Electronic Catalog Suite automatically installs all Carrier Electronic Catalog (E-CAT) programs using a single installation file. This is an alternative to downloading and installing individual E-CAT programs one by one. The October 5, 2012 Electronic Catalog Suite release automatically installs the following programs: X-Builder Framework v1.05b Induction Terminals Builder v1.02 AHUBuilder v6.24 Packaged RTU Builder v1.30 Air Terminal Builder v2.06 Self-Contained Units Builder v2.09t Applied RTU Builder v3.09q Unit Ventilator Builder v1.19d Commercial Split Systems Builder v1.28 Water Source Heat Pump Builder v5.02 Fan Coil Builder v4.02 Programs marked with the symbol have been updated since the September 7, 2012 release. INSTALLATION PROCEDURES Installation via Internet Download Download the ecat-cec20121005.exe file from the Internet site and save it in a folder on your hard disk. Note that the download file is large and a fast internet connection is necessary to efficiently download this file. Run Windows Explorer and double-click on the ecat-cec20121005.exe file. This launches the program installer. Follow the installation instructions that appear on your screen. Note AutoDesk Volo View Express® must also be installed for certain E-CAT programs to function correctly. AutoDesk Volo View Express® can be downloaded from the internet site. Installation via E-CAT CD Insert the E-CAT CD-ROM in your CD drive. On most computers, the software installation will start automatically. If it does not, double click the setup.exe file in the root folder of the CD to launch installation. Follow the installation instructions that appear on your screen. Note AutoDesk Volo View Express® must also be installed for certain E-CAT programs to function correctly. The AutoDesk Volo View Express® installer can be found in the \VoloView folder on the CD. Running the Program Use the following procedure to run the program: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT/E20-II programs. In the Carrier E-CAT/E20-II Programs group click Carrier Electronic Catalog v1.05b. From Electronic Catalog you can run all other E-CAT programs. Minimum Computer Requirements: Hard Disk Space: Up to 556 megabytes when installing software for the first time. The hard disk space requirement is much smaller when updating existing versions of the software. Operating System: Windows XP, Windows Vista or Windows 7. Autodesk Volo View Express®

Transcript of October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Page 1: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogCustomer Suite

Version 20121005Release Sheet

Carrier Electronic Catalog Customer Suite v20121005 replaces v20120907

SOFTWARE DESCRIPTION

The Carrier Electronic Catalog Suite automatically installs all Carrier Electronic Catalog (E-CAT) programs using asingle installation file. This is an alternative to downloading and installing individual E-CAT programs one by one.

The October 5, 2012 Electronic Catalog Suite release automatically installs the following programs:

X-Builder Framework v1.05b Induction Terminals Builder v1.02AHUBuilder v6.24 Packaged RTU Builder v1.30

Air Terminal Builder v2.06 Self-Contained Units Builder v2.09tApplied RTU Builder v3.09q Unit Ventilator Builder v1.19d

Commercial Split Systems Builder v1.28 Water Source Heat Pump Builder v5.02Fan Coil Builder v4.02

Programs marked with the symbol have been updated since the September 7, 2012 release.

INSTALLATION PROCEDURES

Installation via Internet Download Download the ecat-cec20121005.exe file from the Internet site and save it in a folder on your hard disk. Note

that the download file is large and a fast internet connection is necessary to efficiently download this file. Run Windows Explorer and double-click on the ecat-cec20121005.exe file. This launches the program installer. Follow the installation instructions that appear on your screen. Note AutoDesk Volo View Express® must also be installed for certain E-CAT programs to function correctly.

AutoDesk Volo View Express® can be downloaded from the internet site.

Installation via E-CAT CD Insert the E-CAT CD-ROM in your CD drive. On most computers, the software installation will start automatically. If it does not, double click the setup.exe

file in the root folder of the CD to launch installation. Follow the installation instructions that appear on your screen. Note AutoDesk Volo View Express® must also be installed for certain E-CAT programs to function correctly.

The AutoDesk Volo View Express® installer can be found in the \VoloView folder on the CD.

Running the ProgramUse the following procedure to run the program: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT/E20-II programs. In the Carrier E-CAT/E20-II Programs group click Carrier Electronic Catalog v1.05b. From Electronic Catalog

you can run all other E-CAT programs.

Minimum Computer Requirements: Hard Disk Space: Up to 556 megabytes when installing software for the first time. The hard disk space

requirement is much smaller when updating existing versions of the software. Operating System: Windows XP, Windows Vista or Windows 7. Autodesk Volo View Express®

Page 2: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogCustomer Suite

Version 20121005Release Sheet

INSTALLATION PROCEDURES (continued)

Note: Certain E-CAT programs require you to install the current version of Autodesk Volo View Express®programs. This program can be downloaded from the E-CAT download table on the internet site. Volo ViewExpress® (copyright Autodesk, Inc.) is freely distributed by Autodesk, Inc. as its drawing viewer. Any redistributionof Volo View Express® must be in compliance with the Software License Agreement that is displayed during theVolo View Express® installation.

PREVIOUS VERSION INFORMATION

If your computer contains the prior versions of the Carrier E-CAT programs, the E-CAT Suite will automaticallyreplace the prior version when installed. As a result it is not necessary for you to uninstall the prior version beforeinstalling the E-CAT Suite. Exceptions only exist for a major version change or a new program and in that case theprior version can be uninstalled before or after installing the E-CAT Suite.

In the October 5 Customer Suite all releases are minor version updates.

NOTES

1. Release Sheets. Release sheets for individual Electronic Catalog programs are found in the "E-CAT ProductSelection Programs" down load table on the internet site. These sheets describe new program features.

2. Adobe Acrobat. Adobe Acrobat Reader v4.05 or later is required to view certified drawings in certain E-CATprograms. If Acrobat Reader is not yet installed on your computer, the latest version can be downloaded fromwww.adobe.com/products/acrobat and then installed.

Page 3: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

X Builder Framework

v1.05b

Page 4: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogX Builder Framework v1.05b

Release Sheet

X Builder Framework v1.05b replaces v1.05a

PROGRAM DESCRIPTION

X Builder Framework provides common features for most Electronic Catalog and E20 II programs. It can also beused as a central launch portal for all Electronic Catalog software. The software appears as "Carrier ElectronicCatalog" on the Start/Programs Menu.

If you launch the X Builder Framework from the “Carrier Electronic Catalog” icon on the Start Menu you can makebest use of these common features. For example, you can configure any Tag in an existing ECAT Project simply bydouble-clicking the Tag on the Project tree, or create any kind of new Tag in the Project by clicking the New Tagbutton.

X Builder v1.05b includes the following changes: Error messages appearing when a Builder fails to start have been improved to add more information about the

problem that occurred and required corrective action.

In addition, the following problems have been corrected: When the % airflow option was used to enter outdoor airflow in the mixed air calculator, it did not save the

decimal portion of the airflow. For example 20.5% was saved as 20%. As a result mixed air calculation resultswere incorrect.

In certain situations when starting X Builder an “Error in routine:Function IsValidDLL” error message appearedand prevented startup. For most situations this error will no longer occur.

Please refer to the X Builder Support Notes in the Software/Program Downloads section of the web site, or fromCarrier Electronic Catalog’s “Welcome” screen for more information.

INSTALLATION PROCEDURES

Installation via Internet DownloadIf one of the X Builder Framework versions 1.03 thru 1.05a is installed on your computer, you can save time byinstalling a patch update. This is the first procedure below. Otherwise, a full program installation is required. This isthe second procedure below.

To perform a patch install, please use the following procedure: Download the ecatp-xbf105b.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecatp-xbf105b.exe file. This launches the program installer. Follow the installation instructions that appear on your screen.

To perform a full program install, please use the following procedure: Download the ecat-xbf105b.exe file from the internet site and save it in a folder on your hard disk. Close any other programs running on your desktop computer. Run Windows Explorer and double-click on the ecat-xbf105b.exe file. This launches the program installer. Follow the installation instructions, which appear on your screen. After installation you may be asked to reboot.

Running the Program

Use the following procedure to run the program: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT/E20-II programs. In the Carrier E-CAT/E20-II Programs group click on the Carrier Electronic Catalog v1.05b icon.

Page 5: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogX Builder Framework v1.05b

Release Sheet

INSTALLATION PROCEDURES (continued)

Minimum Computer Requirements: Hard Disk Space: 30 megabytes. Random Access Memory: 128 megabytes minimum, 256 megabytes recommended. Display Monitor: At least VGA with 600x800 resolution and 256 colors. Operating System: Windows XP, Windows Vista or Windows 7.

PREVIOUS VERSION INFORMATION

1. X Builder Framework includes prior versions of E-CAT/E20 Configuration Services.

2. Projects and Tags created with E-CAT/E20-II Configuration Services will continue to work as normal withintheir specific selection programs. Additionally, all projects created with 32-bit version of E-CAT programs willbe available in the Project Tool within X Builder.

SPECIAL NOTES

1. Adobe Acrobat, AutoDesk VoloView. Certain X Builder Framework components depend on Adobe AcrobatReader and Autodesk Voloview or TrueView drawing viewer. These components are included in the CDinstalls, but may need to be downloaded and installed separately if you are installing from the internet and yourcomputer does not yet contain this software.

Page 6: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

AHU Builder

v6.24

Page 7: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

September, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogAHUBuilder v6.24

Release Sheet

AHU Builder v6.24 replaces v6.23.

UPDATE DESCRIPTION

AHUBuilder v6.24 includes the following change: Added coil connections on the drawings for indoor horizontal 39S units (39SH).

In addition the following problems were corrected: When performing heating calculations for a cooling coil, an error message "heating capacity cannot be met" was

incorrectly displayed. When performing cooling calculations for a hating coil, an error message "cooling capacity cannot be met" was

incorrectly displayed. Weights for 39M and 39S Certified Drawings were shown in lbs. instead of in kg when the units of measure were

Metric. Under certain conditions, 39M DX coil calculations would display the error "Division by zero". Under certain conditions, 39S Steam coil calculations would display the error "Subscript out of Range".

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a patch update program install, please use the following procedure: Download the ecatp-sd3624.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecatp-sd3624.exe file. This launches the program installer. Follow the installation instructions that appear on your screen. Note that X Builder Framework and AutoDesk Volo View Express® must also be installed for AHUBuilder to

function correctly. Both can be downloaded from the internet site.

Running the Program:Carrier Electronic Catalog can be used to launch AHUBuilder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing tags via the Project tab, or you can directly launch the program via thePrograms tab.

AHUBuilder can also be launched from the Start Menu: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. Then choose Individual Product Builders. Finally click on the AHUBuilder v6.24 item.

Minimum Computer Requirements: Hard Disk Space: 30 megabytes (for program and submittal drawing managers) Operating System: Windows XP, Windows Vista or Windows 7. Autodesk Volo View Express®

Note: X-Builder Framework and Autodesk Volo View Express® programs should be installed prior to installing andrunning AHU Builder. Both can be downloaded from the internet site. Volo View Express® (copyright Autodesk,Inc.) is freely distributed by Autodesk, Inc., as its drawing viewer. Any redistribution of Volo View Express® mustbe in compliance with the Software License Agreement which is displayed during the Volo View Express®installation.

Page 8: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

September, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogAHUBuilder v6.24

Release Sheet

PREVIOUS VERSION INFORMATION

1. AHU Builder v6.24 will replace v6.23 automatically. It is not necessary to uninstall v6.24 before installing v6.23.

2. Existing projects created with AHU Builder v6.23 can be used immediately in v6.24a. To ensure that all tags arevalid and up to date in the new version, open the project and then click on each Tag in turn to update and validate.

SPECIAL NOTES

1. XBuilder The latest version of X Builder Framework should be installed before installing AHU Builder.

2. AutoDesk VoloView Express® must be installed in order to view DXF Certified and Template drawings in theprogram.

Page 9: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Air Terminal Builder

v2.06

Page 10: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 3

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogAir Terminal Builder v2.06

Release Sheet

Air Terminal Builder v2.06 replaces v2.05

UPDATE DESCRIPTION

Air Terminal Builder v2.06 corrects the following problems: When the Performance Summary, Unit Report or Acoustic Report was generated, error messages appeared

embedded in the report text. This made the report unreadable. For 35E single duct terminals with round outlet factory option, the outlet dimensions were incorrectly displayed

on the Performance Summary report as rectangular dimensions. For 35E single duct terminals, the description for AUD0 and AUE0 controllers/actuator were incorrect.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-atb206.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-atb206.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: The current X Builder Framework should be installed prior to installing the Air Terminal Builder. It can

be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Air Terminal Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing tags via the Project tab, or you can directly launch the program viathe Programs tab.

Minimum Computer Requirements: Hard Disk Space: Up to 37 megabytes Operating System: Windows XP, Windows Vista or Windows 7. The current XBuilder Framework should be installed prior to installing the Air Terminal Builder. Autodesk Volo View Express®

Please note that Air Terminal Builder requires that you download and install the current X Builder Framework andthe AutoDesk VoloView Express® programs. Both of these can be downloaded from the E-CAT download table onthe internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributed by AutoDesk Inc., as itsdrawing viewer. Any redistribution of VoloView Express® must be in compliance with the Software LicenseAgreement which is displayed during the VoloView Express® installation.

PREVIOUS VERSION INFORMATION

1. Air Terminal Builder v2.06 will replace v2.05 automatically. It is not necessary to uninstall v2.05 beforeinstalling v2.06.

2. Existing projects created with Air Terminal Builder v2.05 can be used immediately in v2.06, but they willinitially contain only invalid tags. To quickly make all tags valid in the new version, highlight the project namein the projects tree on the left and then click the “Update All Tags” button at the bottom of the right hand pane.

Page 11: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 2 of 3

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogAir Terminal Builder v2.06

Release Sheet

SPECIAL NOTES

1. X-Builder Framework. The current version of XBuilder Framework should be installed before installing AirTerminal Builder.

2. Adobe Acrobat. Adobe Acrobat Reader v4.05 or later is required to view certified drawings. If this softwarehas not yet been installed on your computer, download the latest version of Adobe Acrobat Reader fromwww.adobe.com/products/acrobat and install it.

3. VoloView. VoloView v2020-129 or later is required to view CAD templates from within Commercial SplitSystems Builder. If this software has not yet been installed on your computer, you can do so by runningWindows Explorer, navigating to the \VOLO_NEW folder on the E-CAT CD and then double-clicking on theVVE2SETUP.EXE file. Note that if you do not intend to view templates within Commercial Split SystemsBuilder, this software is not needed. Many users display template drawings using a CAD system such asAutoCAD instead.

Page 12: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Applied RTU Builder

v3.09q

Page 13: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

September, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogApplied RTU Builder v3.09q

Release Sheet

Applied RTU Builder v3.09q replaces v3.09p.

PROGRAM DESCRIPTION

Applied RTU Builder v3.09q corrects the following problems: For P series units with high capacity power exhaust selected an invalid part number was generated. This error

resulted in quotes for these units not being approved in SAP. In the Performance Summary Report, the power exhaust fan curve displayed an incorrect maximum hp value. The minimum allowable airflow for P series size 090 was incorrect. It was shown as 17,000 CFM instead of

18,000 CFM. This error caused performance calculations to fail airflow was set to a value less than 18,000 CFM.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-rtu309q.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-rtu309q.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: AutoDesk VoloView Express® and the latest X Builder Framework should be installed prior to installing

the Applied RTU Builder. Both can be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Applied RTU Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing rooftop tags via the Project tab, or you can directly launch theprogram via the Programs tab.

Minimum Computer Requirements: Hard Disk Space: 40 megabytes Operating System: Windows XP, Windows Vista or Windows 7. The latest X Builder Framework should be installed prior to installing the Applied RTU Builder. AutoDesk VoloView Express®

AutoDesk VoloView Express® and the latest X Builder Framework should be installed before running this program.Both can be downloaded from the internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributedby AutoDesk Inc., as its drawing viewer. Any redistribution of VoloView Express® must be in compliance with theSoftware License Agreement which is displayed during the VoloView Express® installation.

PREVIOUS VERSION INFORMATION

1. Applied RTU Builder v3.09q will replace v3.09p automatically. It is not necessary to uninstall v3.09p beforeinstalling v3.09q.

2. Existing projects created with Applied RTU Builder v3.09p can be used immediately in v3.09q, but they willinitially contain only invalid tags. To quickly make all tags valid in the new version, highlight the project namein the projects tree on the left and then click the “Update All Tags” button which appears at the bottom of theright hand pane.

Page 14: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

September, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogApplied RTU Builder v3.09q

Release Sheet

SPECIAL NOTES

1. XBuilder The latest version of X Builder Framework should be installed before installing Applied RTU Builder.

2. AutoDesk VoloView Express® must be installed in order to view DXF template drawings in the program.

Page 15: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Commercial Split Systems Builder

v1.28

Page 16: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 3

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogCommercial Split Systems Builder v1.28

Release Sheet

Commercial Split Systems Builder v1.28 replaces v1.27

UPDATE DESCRIPTION

Commercial Split Systems Builder v1.28 includes the following changes: Added specification of separate voltages for 208V-60Hz or 230V-60Hz. Electrical data on the Performance

Report will be for the selected voltage, except for 38AP, 38AH and 38AKS models where combined 208V/230Velectrical data is still shown.

Added an informative message on the Design Criteria tab for 38AH and 38AKS models indicating the maximumlinear separation and vertical liquid lift.

Added a note stating the indoor unit drive range to the Performance Summary report. Added an Advanced Acoustical Analysis feature to analyze acoustic performance when barriers or reflective

walls are present. To use this feature click the Advanced Acoustic" button on the Design Criteria tab. Inaddition, advanced acoustics results were added to the Performance Summary Report and the Acoustics Report.

Added an option to display net cooling capacities for indoor units on the Performance Summary report. To selectthis option choose the Options item on the Programs menu. Then click the Commercial Splits tab in the Optionswindow and check the box for "Include Net Ratings".

Added shading to the fan curve on the Performance Summary report to show the valid airflow range for theselected unit size.

Added a message to the electrical data section of the Performance Summary report which reads “Control PanelSCCR: 5kA RMS at Rated Symmetrical Voltage”.

Updated electrical data for 40RU indoor unit with 2-speed VFD controller factor option and high efficiencymotor.

Revised the required quantity for low ambient kits (Motormaster) for 38AP sizes 070-130. A quantity of 2 isnow required for these sizes.

In addition the following problem was corrected: For 40RU indoor models using the 2-speed VFD controller factor option and "High Efficiency" motor, the motor

efficiency was incorrectly displayed as "Standard Efficiency".

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-csb128.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-csb128.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: AutoDesk VoloView Express® and the latest X Builder Framework should be installed prior to installing

the Commercial Split Systems Builder. Both can be downloaded from the internet site.

Running the Program

Carrier Electronic Catalog can be used to launch Commercial Split Systems Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing tags via the Project tab, or you can directly launch the program viathe Programs tab.

Minimum Computer Requirements: Hard Disk Space: Up to 50 megabytes Operating System: Windows XP, Windows Vista or Windows 7. Autodesk Volo View Express®

Page 17: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 2 of 3

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogCommercial Split Systems Builder v1.28

Release Sheet

INSTALLATION PROCEDURES

Please note that Commercial Split Systems Builder requires that you download and install X Builder Framework andthe AutoDesk VoloView Express® v2000-129 programs. Both of these can be downloaded from the E-CATdownload table on the internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributed byAutoDesk Inc., as its drawing viewer. Any redistribution of VoloView Express® must be in compliance with theSoftware License Agreement which is displayed during the VoloView Express® installation.

PREVIOUS VERSION INFORMATION

1. Commercial Split Systems Builder v1.28 will replace v1.27 automatically. It is not necessary to uninstall v1.27before installing v1.28.

2. Existing projects created with Commercial Split Systems Builder v1.27 can be used immediately in v1.28, butthey will initially contain only invalid tags. To quickly make all tags valid in the new version, highlight theproject name in the projects tree on the left and then click the “Update All Tags” button which appears at thebottom of the right hand pane.

SPECIAL NOTES

1. XBuilder. The latest version of XBuilder Framework should be installed before installing Commercial SplitSystems Builder.

2. Adobe Acrobat. Adobe Acrobat Reader v4.05 or later is required to view certified drawings. If Acrobat Readeris not yet installed on your computer, the latest version can be downloaded fromwww.adobe.com/products/acrobat and then installed.

3. AutoDesk VoloView Express® must be installed in order to view DXF template drawings in the program.

Page 18: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Fan Coil Builder

v4.02

Page 19: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

April, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogFan Coil Builder v4.02

Release Sheet

Fan Coil Builder v4.02 replaces v4.00

UPDATE DESCRIPTION

Fan Coil Builder v4.02 the includes changes: Added 42SM mega furred-in stack unit designed for applications requiring units with increased capacity. Enhanced the Performance Report and Acoustic Report by adding discharge sound power acoustic data for

certain models Enhanced the Equipment Schedule report to include all the items displayed in the Tag Grid. This report is

displayed in a spreadsheet format. Enhanced the Tag Grid to automatically validate tags. This eliminates the need to open each tag individually to

make it valid and makes using the grid feature significantly more efficient for users.

In addition the following problems were corrected in v4.01: For certain fan coil units, the unit dimensions displayed on the Unit Report were incorrect. When a tag contained warranties and that tag was modified using the Tag Grid, the program incorrectly removed

all warranties from the tag.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-fcb402.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-fcb402.exe file. This launches the program installer. Follow the installation instructions that appear on your screen. Note: The current version of X Builder Framework and AutoDesk VoloView Express® should be installed prior

to installing the Fan Coil Builder. Both can be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Fan Coil Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing fan coil tags via the Project tab, or you can directly launch theprogram via the Programs tab.

Minimum Computer Requirements: Hard Disk Space: 20 megabytes Operating System: Windows XP, Windows Vista or Windows 7. The current version of XBuilder Framework should be installed prior to installing the Fan Coil Builder.

PREVIOUS VERSION INFORMATION

1. Fan Coil Builder v4.02 will replace v4.00 automatically. It is not necessary to uninstall v4.00 before installingv4.02.

2. Existing projects created with Fan Coil Builder v4.00 can be used immediately in v4.02, but they will initiallycontain only invalid tags. To quickly make all tags valid in the new version, highlight the project name in theprojects tree on the left and then click the “Update All Tags” button which appears at the bottom of the righthand pane.

Page 20: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

April, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogFan Coil Builder v4.02

Release Sheet

PREVIOUS VERSION INFORMATION (continued)

3. Tags in existing projects created with Fan Coil Builder v3.39g or earlier versions can be used in v4.02, howevertags in these projects must be converted before they can be used with v4.02. To convert the tags, use thefollowing steps: Start Fan Coil Builder v4.02. Choose the "Convert Project" item on the File Menu. A window will appear listing all current projects that contain v3.30 through 3.39g tags. Select all projects

whose tags you wish to convert. Then press OK. Tags in the selected projects will be converted. When you are returned to the program main window, the tags are ready for use with v4.02.

This conversion process has been tested with version 3.39g. Conversion of prior version tags is not guaranteed,but the more recent the tag, the better its chance of successful conversion. If you encounter problems with anearlier tag, you can first run Fan Coil Builder v3.39g, select a project in the project tree on the left and then clickthe "Update All Tags" button at the bottom of the right hand panel this converts the data to v3.39g compatibility.Then convert the tags to v4.00 using the bullets above.

4. Fan Coil Builder v4.02 will not replace v3.39g automatically. Version 3.39g must be uninstalled separatelyusing the following procedure: Start Electronic Catalog. In the main window click the Programs tab. Highlight Fan Coil Builder v3.3 in the tree on the left. Then click the "Remove Program" button in the right-hand panel.

SPECIAL NOTES

1. XBuilder. The latest version of XBuilder Framework should be installed before installing Fan Coil Builder.

Page 21: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Induction Terminals Builder

v1.02

Page 22: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

August, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogInduction Terminal Builder v1.02

Release Sheet

Induction Terminal Builder v1.02 replaces v1.01

UPDATE DESCRIPTION

Induction Terminal Builder v1.02 includes the following changes: Added the 36CB Chilled Beam products which were previously offered in the Air Terminal Builder. All

selections for this model must be done using this builder. Added the 36R/S/T Induction Unit products which were previously offered in the Air Terminal Builder. All

selections for this model must be done using this builder. Added a new toolbar button which can be used to display tags in the Tag Grid where you can quickly view and

modify the tags. Updated the What’s This help items for the base unit model and factory options tabs were.

In addition, the following problem was corrected: The certified drawings for 36IB, Induction Terminal with 4 way Narrow discharge style for sizes 48x12 and

48x24 were incorrect. The drawings were switched so the 48x12 was displayed for the 48x24 and vice versa. On the design criteria tab for the 36IB, Induction Terminal models, the Airflow per Person was shown as the

default selection instead of Primary Airflow. On the Equipment Schedule report, when running in SI Metric units, data was incorrectly displayed in English

units.

INSTALLATION PROCEDURES

Installation via Internet Download

To perform a full install, please use the following procedure: Download the ecat-cbb102.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-cbb102.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note that X Builder Framework v1.04w should be installed prior to installing Induction Terminal Builder. It can

be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Induction Terminal Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing induction terminal tags via the Project tab, or you can directly launchthe program via the Programs tab.

Minimum Computer Requirements:

Hard Disk Space: Up to 50 megabytes Operating System: Windows XP, Windows Vista or Windows 7. XBuilder Framework v1.04w should be installed prior to installing the Induction Terminal Builder. Autodesk Volo View Express®

Please note that Induction Terminal Builder requires that you download and install X Builder Framework v1.04w andthe AutoDesk VoloView Express® programs. Both of these can be downloaded from the E-CAT download table onthe internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributed by AutoDesk Inc., as itsdrawing viewer. Any redistribution of VoloView Express® must be in compliance with the Software LicenseAgreement which is displayed during the VoloView Express® installation.

Page 23: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

August, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogInduction Terminal Builder v1.02

Release Sheet

PREVIOUS VERSION INFORMATION

1. Induction Terminal Builder v1.02 will replace v1.01 automatically. It is not necessary to uninstall v1.01 beforeinstalling v1.02.

2. Existing projects created with Induction Terminal Builder v1.01 can be used immediately in v1.02, but they willinitially contain only invalid tags. To quickly make all tags valid in the new version, highlight the project namein the projects tree on the left and then click the “Update All Tags” button at the bottom of the right hand pane.

PROGRAM DOCUMENTATION

Standard documentation is provided in the program's help system. To access help use the Help option on theInduction Terminal Builder menu bar, or press the [F1] key at any point during program operation.

SPECIAL NOTES

1. XBuilder. The latest version of XBuilder Framework should be installed before installing Induction TerminalBuilder.

Page 24: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Packaged RTU Builder

v1.30

Page 25: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogPackaged RTU Builder v1.30

Release Sheet

Packaged RTU Builder v1.30 replaces v1.29z.

UPDATE DESCRIPTION

Packaged RTU Builder v1.30 includes the following changes Added a message to the Factory Options tab of the configurator to warn users selecting a unit for 50hz applications

that PremierLink controls operate only in English language and support SI Metric and Inch-Pound units, and thatRTU Open controls operate only in English language and Inch-Pound units. The same warning message was addedto the Performance Summary report.

Added 2 speed indoor fan motor option and HumidiMizer options for 48/50 HCX EnergyX models. Added 48/50HCX size 11 (12 EER) with 2 speed indoor fan motor option. Added unit operating weight data for 50TC export models. Reinstated the ComfortLink and 2-speed indoor fan motor options for 48/50HC units. The factory installed option,

HumidiMizer, was also made available with 2 speed indoor fan motor option. Removed available blanket quote controls from 50TCQ size 14 and 50HCQ size 12.

In addition the following problems were corrected: For 50TCQ 17 to 25 ton units, the coil option descriptions which appear on the Factor Options tab and the extended

descriptions appearing in QuoteBuilder were incomplete. The text only described material for one coil. Roof curb certified drawings for 48/50 HCX with EnergyX were not included in the submittal drawings. For 48/50LC 3 to 5 ton units, 48/50HC 3 to 12.5 ton units, and 50HCQ 3 to 10 ton units, the HACR Circuit Breaker

option was incorrectly offered when MOCP electrical rating exceeded 100 amps at 208/230V, 90amps at 460V and70 amps at 575V.

For 48/50HC 15 to 25 ton units, the HACR Circuit Breaker option was incorrectly offered when MOCP electricrating exceeded 200 amps at 208/230V, 90 amps at 460V and 90 amps at 575V.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-prb130.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-prb130.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: AutoDesk VoloView Express® and the latest X Builder Framework should be installed prior to installing

the Packaged RTU Builder. Both can be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Packaged RTU Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing tags via the Project tab, or you can directly launch the program viathe Programs tab.

Minimum Computer Requirements: Hard Disk Space: 40 megabytes. Operating System: Windows XP, Windows Vista or Windows 7. The latest X Builder Framework should be installed prior to installing the Packaged RTU Builder. AutoDesk VoloView Express®

AutoDesk VoloView Express® and the latest X Builder Framework should be installed before running this program.Both can be downloaded from the internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributedby AutoDesk Inc., as its drawing viewer. Any redistribution of VoloView Express® must be in compliance with theSoftware License Agreement which is displayed during the VoloView Express® installation.

Page 26: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogPackaged RTU Builder v1.30

Release Sheet

PREVIOUS VERSION INFORMATION

1. Packaged RTU Builder v1.30 will replace v1.29z automatically. It is not necessary to uninstall v1.29z beforeinstalling v1.30.

2. Existing projects created with Packaged RTU Builder v1.29z can be used immediately in v1.30, but they willinitially contain only invalid tags. To quickly make all tags valid in the new version, highlight the project namein the projects tree on the left and then click the “Update All Tags” button at the bottom of the right hand pane.

SPECIAL NOTES

1. XBuilder The latest version of X Builder Framework should be installed before installing Packaged RTUBuilder.

2. AutoDesk VoloView Express® must be installed in order to view DXF template drawings in the program.

Page 27: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

SCU Builder

v2.09t

Page 28: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 1

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogSCUBuilder v2.09t

Release Sheet

SCU Builder v2.09t replaces v2.09s

PROGRAM DESCRIPTION

SCU Builder v2.09t includes the following changes: Updated the 50XJ model line with new configuration options, drawings and R410a refrigerant performance. The performance data for the 50XCR16 unit is now matched to the 09XC24 remote condensing unit. Upgraded the Mixed Air Calculator feature to save inputs from any previous mixed air calculation (in each Tag).

The stored inputs are restored for any recalculation, so you only have to revise inputs as necessary rather thanentering all the outside air and return air data all over again.

In addition, the following problems were corrected: When 50XCA or 50AH air-cooled self-contained units were selected via the selection wizard, the Factory

Options tab would display as invalid until the tag was reloaded. Unit Sizes for the 50XCW model line were not sorted in increasing order of size.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full install, please use the following procedure: Download the ecat-scu209t.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-scu209t.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note that X Builder Framework should be installed prior to installing SCU Builder. It can be downloaded from

the internet site.

Running the ProgramUse the following procedure to run the program: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT/E20-II programs. In the Carrier E-CAT/E20-II Programs group choose Individual Product Builders. In the Individual Product Builders group click on the SCU Builder v2.09t item.

Minimum Computer Requirements: Hard Disk Space: Up to 50 megabytes Operating System: Windows XP, Windows Vista, or Windows 7. The current X Builder Framework should be should be installed prior to installing the SCU Builder.

PREVIOUS VERSION INFORMATION

1. SCU Builder v2.09t will replace v2.09s automatically. It is not necessary to uninstall v2.09s before installingv2.09t.

2. Data created with v2.09s is immediately usable in SCU Builder v2.09t. There is no data conversion required.However, to make all your tags valid in v2.09t, highlight the Project name in the Projects tree and then click onthe button “Update and Recalculate all Tags”.

SPECIAL NOTES

1. X Builder. The latest version of XBuilder Framework should be installed before installing SCU Builder.

Page 29: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

Unit Ventilator Builder

v1.19d

Page 30: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

August, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogUnit Ventilator Builder v1.19d

Release Sheet

Unit Ventilator Builder v1.19d replaces v1.19c.

UPDATE DESCRIPTION

Unit Ventilator Builder v1.19d includes changes that were relevant only to Carrier sales offices.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full install, please use the following procedure: Download the ecat-uvb119d.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-uvb119d.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: AutoDesk VoloView Express® and the current version of X Builder Framework should be installed prior

to installing the Unit Ventilator Builder. Both can be downloaded from the internet site.

Running the ProgramCarrier Electronic Catalog can be used to launch Unit Ventilator Builder. To start Electronic Catalog: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT and E20-II programs. In the Carrier E-CAT and E20-II Programs group choose the Carrier Electronic Catalog item. From Electronic

Catalog you can create new or edit existing fan coil tags via the Project tab, or you can directly launch theprogram via the Programs tab.

Minimum Computer Requirements: Hard Disk Space: Up to 37 megabytes Operating System: Windows XP, Windows Vista or Windows 7. The current X Builder Framework should be installed prior to installing Unit Ventilator Builder. Autodesk Volo View Express®

Please note that Unit Ventilator Builder requires that you download and install the current X Builder Framework andthe AutoDesk VoloView Express® programs. Both of these can be downloaded from the E-CAT download table onthe internet site. VoloView Express® (copyright Autodesk, Inc.) is freely distributed by AutoDesk Inc., as itsdrawing viewer. Any redistribution of VoloView Express® must be in compliance with the Software LicenseAgreement which is displayed during the VoloView Express® installation.

PREVIOUS VERSION INFORMATION

1. Unit Ventilator Builder v1.19d will replace v1.19c automatically. It is not necessary to uninstall v1.19c beforeinstalling v1.19d.

2. Existing projects created with Unit Ventilator Builder v1.19c can be used immediately in v1.19d, but they willinitially contain only invalid tags. To quickly make all tags valid in the new version, highlight the project namein the projects tree on the left and then click the “Update All Tags” button which appears at the bottom of theright hand pane.

Page 31: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

August, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogUnit Ventilator Builder v1.19d

Release Sheet

SPECIAL NOTES

1. X-Builder Framework. The current version of XBuilder Framework should be installed before installing UnitVentilator Builder.

2. Adobe Acrobat. Adobe Acrobat Reader v4.05 or later is required to view certified drawings. If this softwarehas not yet been installed on your computer, download the latest version of Adobe Acrobat Reader fromwww.adobe.com/products/acrobat and install it.

5. VoloView. VoloView v2000-129 or later is required to view template drawings from within Commercial SplitSystems Builder. If this software has not yet been installed on your computer, you can do so by runningWindows Explorer, navigating to the \VOLO_NEW folder on the E-CAT CD and then double-clicking on theVVE2SETUP.EXE file. Note that if you do not intend to view templates within Commercial Split SystemsBuilder, this software is not needed. Many users display template drawings using a CAD system such asAutoCAD instead.

Page 32: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

WSHP Builder

v5.02

Page 33: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 1 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogWSHP Builder v5.02

Release Sheet

WSHP Builder v5.02 replaces v5.01

UPDATE DESCRIPTION

WSHP Builder v5.02 includes the following changes: Added a convenient means of switching to multi-tag grid view via a button on the Project Properties screen and

on the X Builder toolbar. Previously the Grid View could only be displayed by clicking the Tags node in theProject tree.

Added a secondary circulation pump option for 50PEC and 50RTP models. Upgraded the Mixed Air Calculator feature to save inputs from any previous mixed air calculation (in each Tag).

The stored inputs are restored for any recalculation, so you only have to revise inputs as necessary rather thanentering all the outside air and return air data all over again.

Updated electrical data for 50PEC units. Changed stainless steel drain pan to a standard option for 50VQP Export (50 Hz) units. Tags in existing projects

which include the stainless steel drain pan factory option will update their part numbers to indicate the standarddrain pan (now stainless steel) is used when existing projects are converted for v5.02.

In addition, the following problems have been fixed in this release: 50HQP models were incorrectly labeled as single-stage. They are 2-stage units. Unit Tags from the previous version failed to update to the latest version when loaded into the Grid.

INSTALLATION PROCEDURES

Installation via Internet DownloadTo perform a full program install, please use the following procedure: Download the ecat-wsh502.exe file from the Internet site and save it in a folder on your hard disk. Run Windows Explorer and double-click on the ecat-wsh502.exe file. This launches the program installer. Follow the installation instructions which appear on your screen. Note: AutoDesk VoloView Express® and the latest X Builder Framework should be installed prior to installing

the Water Source Heat Pump Builder. Both can be downloaded from the internet site.

Running the Program

Use the following procedure to run the program: From the Windows desktop press Start, choose Programs and then choose Carrier E-CAT/E20-II Programs. In the Carrier E-CAT/E20-II Programs group click on the Individual Product Builders icon. In the Individual Product Builders group click on the WSHP Builder v5.02 icon.

Minimum Computer Requirements: Hard Disk Space: 20 megabytes Operating System: Windows XP, Windows Vista or Windows 7. The current X Builder Framework should be installed prior to installing WSHP Builder.

PREVIOUS VERSION INFORMATION

1. WSHP Builder v5.02 will replace v5.01 automatically. It is not necessary to uninstall v5.01 before installingv5.02.

2. Existing projects created with WSHP Builder v5.02 can be used immediately in v5.01, but they will initiallycontain only invalid tags. To quickly make all tags valid in the new version, highlight the project name in theprojects tree on the left and then click the “Update All Tags” button at the bottom of the right hand pane.

Page 34: October, 2012 Page 1 of 2 Carrier Electronic Catalog Customer

October, 2012 Page 2 of 2

Carrier Software SystemsSyracuse, NY, USA

[email protected]

Carrier Electronic CatalogWSHP Builder v5.02

Release Sheet

SPECIAL NOTES

1. X Builder. The current X Builder Framework should be installed prior to installing WSHP Builder.