Notice d’instruction TOURELLE F400-120 INSTRUCTIONS FOR THF/TVF ROOF FAN F400-120 UNIT Air Trade Centre Belgium Hoogstraat 180, 1930 Zaventem Tél. : +32.(0)2.725.31.80 – Fax : +32.(0)2.711.46.51 Q013 – THF/TVF – 20/11/2012 illustrations non contractuels ……...……… Before installation or using, read carefully this notice This note must be supplied to the final customer. Le Directeur d’Usine M. REGNIER TOURELLE TVF-V 1812-CPD-0057

Transcript of NOTICE D’INSTRUCTION TOURELLE DE DESENFUMAGE F400-120 …€¦ · C ett no t ic doi ê r fou ni...

Page 1: NOTICE D’INSTRUCTION TOURELLE DE DESENFUMAGE F400-120 …€¦ · C ett no t ic doi ê r fou ni au ln . This note must be supplied to the final customer. Le Directeur d’Usine

Notice d’instruction TOURELLE F400-120

NOTICE D’INSTRUCTION TOURELLE DE DESENFUMAGE F400-120 THF/TVF

INSTRUCTIONS FOR THF/TVF ROOF FAN F400-120 UNIT

Air Trade Centre Belgium

Hoogstraat 180, 1930 ZaventemTél. : +32.(0)2.725.31.80 – Fax : +32.(0)2.711.46.51

Q01

3 –

THF/

TVF

– 20

/11/

2012

il

lust

ratio

ns n

on c

ontra

ctue

ls

……

...…

……

Avant d’installer ou d’utiliser le produit, lire attentivement cette noticeBefore installation or using, read carefully this notice

Cette notice doit être fournie au client final. This note must be supplied to the final customer.

Le Directeur d’Usine M. REGNIER

TOURELLE TVF-V

1812-CPD-0057

Page 2: NOTICE D’INSTRUCTION TOURELLE DE DESENFUMAGE F400-120 …€¦ · C ett no t ic doi ê r fou ni au ln . This note must be supplied to the final customer. Le Directeur d’Usine

Notice d’instruction TOURELLE F400-120

Refer to the marking plate on the equipment - The equipment’s characteristics, power, current, speed of rotation, voltage and frequency are marked on the descriptive label. - The sound level of these machines measured at a distance of 8 m in a free hemispherical field, is less than 70 dB (A).

Check the condition of the packaging and contents at the time of delivery. Any reservations should be reported to the shipper within 48 h. Before being shipped, our equipment is tested under power to check current ratings and that the roof fan is perfectly balanced.

Any disassembly or re-assembly of the fan or motor is entirely at the installer’s liability. The equipment must be mounted HORIZONTALLY on its base, using the Ø14 mm fixing holes provided for the purpose at each corner of the base plate. NB. An inclination of ≤ 6° is acceptable. - To use the equipment with a voltage regulator, starter, frequency controller or electrical control panel, refer to the instructions supplied with these devices. - It’s obligatory to install a lockable security switch for each speed. Moreover, electric cables must be insulated of contact with metallic parts. - It is the installer’s responsibility to fulfil these obligations. We can supply the appropriate parts as options - Check that the fan turns in the direction indicated by the arrow on the driving tray. Ensure this is true of both speeds on two-speed motors. -Smoke removal roof fans must be powered using a CR1_C1 high temperature cable. - When connecting the unit, follow the manufacturer’s wiring indications on the diagram in the terminal box. - Check that the equipment’s voltage, frequency and number of phases match those available onside - Access to the motor is gained by removing the top cover. Cut the electrical power and wait for the complete stop of elements before intervening.

Maintenance and servicing

IMPORTANT! Always condemn the power supply using the nearby padlockable switch (supplied) -The IP55 motors are equipped with ready-greased sealed bearings. -Ensure that the plastic-coated motor parts (e.g. motor seal) are not liable to be damaged by cleaning products. -Should the fan unit be removed from its four mountings for handling reasons, ensure that the mountings do not hit or snag the turbine which would certainly be unbalanced as a result. Belt tension and wear should be checked periodically. Only qualified personnel are to carry out maintenance work on the equipment.

Technical characteristics

Equipment reception and handling

Installation – Electr ical connections

Maintenance must be realized by technically qualifi ed staff.

Only qualified technicians are to carry out electri cal connection work.

Use the necessary physical protections to avoid wou nds due to the

electric and mechanical risks (cutting edges…)

ENGLISH : Translation of the original note