New Pump Fillage in Wells Producing Viscous Crude · 2012. 11. 20. · CAMPO BOSCAN-CHEVRON 45.1...
Transcript of New Pump Fillage in Wells Producing Viscous Crude · 2012. 11. 20. · CAMPO BOSCAN-CHEVRON 45.1...
-
Pump Fillage in Wells Producing Viscous Crude
Pump Fillage in Pump Fillage in Wells Producing Viscous CrudeWells Producing Viscous Crude
Henry Cumare Henry Cumare UPCO DE VENEZUELA, S. A.UPCO DE VENEZUELA, S. A.
2006 2006 International International Sucker Rod Sucker Rod
Pumping Pumping WorkshopWorkshop
Houston, TexasHouston, Texas -- September 14 September 14 -- 15, 200615, 2006
web: www.upcovzla.com
-
Opreration conditions
RESUMEN DIAGNOSTICO. CONDICIONES DE OPERACIÓN DE LA BOMBACAMPO BOSCAN-CHEVRON
45.1
22.025.3
29.0
9.0
36.0
0
10
20
30
40
50
INTERFERENCIA POR GAS LLENADO INCOMPLETO FUGA EN VALVULAS
(%)
1er PROYECTO 2do PROYECTO
Gas interference, leaking traveling valves y heavy crude incomplete fillage became the main reasons for losing pump and system efficiency en Boscan Field .
-
Pump % fillage ranged from 31.24% to a maximum of 96% A downhole gas separator could increase production by 20%
-
Parameters to identify incomplete fillage for gas interference1. Dynamometer card
In the Dynamometer card it can be observed incomplete fillage for gas interference
Well BN0532
0 221.5-2.5
0
2.5
5.0
7.5
10.0
12.5
15.0Fo Max
0 221.5-2.5
0
2.5
5.0
7.5
10.0
12.5
15.0Fo Max
-
Parameter to identify gas interference2. Fluid level. √3. Annular gas flow. √
01
23
45
67
89
1011
1213
1415
1617
1819
2021
2223
2425
26S
ec
31.6 mV
0 2.00-0.20
0
0.20
0.40
0.60
0.80
1.00
3.80
4.00
4.20
4.40
4.60
4.80
Delta Time (min.)
Delta
Pre
ssur
e(p
si)
Casing Pressure
(psi (g))
-
In this chart 41 wells presented incomplete fillage due to gas interference
Porcenaje de Llenado. Columna de liquido Equivalente libre de gas > 90 %
31
36 3638 39
40 4143 44 44
4649 50
54 5556 57
59 59 6061
64 6465 65
67 6869
7072 72 73 73 73
74 74 75
7982
88
95
32
6568
71
21 20 20
5755
20
6265
43
48
69
10
5558
43
33
22
69 6871
20
29
75
53
45
7067
15 15
76
21
1715
55
12
27
61
0
10
20
30
40
50
60
70
80
90
100
532 734 116 699 315 118 131 119 117 126 694 745 680 127 163 601 204 196 209 103 646 130 107 101 367 174 122 682 173 608 200 690 716 106 744 662 769 136 110 105 758
Pozos
% L
lena
do
% Llenado % Gas en el Anular
-
0 188.1-3.125
0
3.125
6.250
9.375
12.500
15.625Fo Max
PUMP FILLAGE 43 %
BN-119
BN-131
PUMP FILLAGE 41 %
Pump Conditions
0 182.3-1.5625
0
1.5625
3.1250
4.6875
6.2500
7.8125
9.3750Fo Max
-
24 BPD42.3 BPD
44 BPD 34 BPD
-
Incomplete Fillage for flowRestriction , High viscosity , Heavy crude
-
Incomplete fillage due to flow restriction in the pump intake , 90 % liquid
Porcenaje de Llenado. Columna de liquido Equivalente libre de gas > 90 %
4750
5355 56
6365
70 70
76 7780
83 84 8487 87 87
90
96
4
9 84
10
53
6
02
4 56
2 2
8
20
3
0
20
40
60
80
100
120
112 663 156 771 601 222 733 719 347 102 414 743 718 772 108 746 406 407 149 169
Pozos
% L
lena
do
% Llenado % Gas en el Anular
1-3/42-1/4 2-1/4
2-1/4 1-3/4
2-1/4 2-1/4
1-3/4 1-3/4
1-3/4 1-3/41-3/4
1-3/4 1-3/4 2-1/42-1/4 1-3/4 1-3/4
1-3/4
2-1/4
7.263.00 5.71
5.64 4.88
6.92 4.96
5.44 5.13
4.28 7.035.99
5.98 6.10 2.843.07 6.52 6.08
6.08
5.73
192240 240
216 216
240 216
216 120
144 114216
216 216 201216 120 120
240
240
-
ING. HERDLY ESCALANTE
Possible solutionsGas separator , and Hi Volume and compression valve
-
High compression and volume type valve Possible solution for this problem , before testing a gas separator
-