New Hi Safe Probe For 10+Gbps Fault Insertion

11
NEW HiSAFE PROBE for 10+Gbps Fault Insertion Preliminary results on prototypes of the new differential probe By Piero Belforte, March 2010

description

Preliminary performance results for a new HiSAFE probe type for 10Gbps Fault Insertion applications are shown.

Transcript of New Hi Safe Probe For 10+Gbps Fault Insertion

Page 1: New Hi Safe Probe For 10+Gbps Fault Insertion

NEW HiSAFE PROBE for 10+Gbps Fault Insertion

Preliminary results on prototypes of the new differential probe

By Piero Belforte, March 2010

Page 2: New Hi Safe Probe For 10+Gbps Fault Insertion

Test setup

• As test setup the OL1 microstrip pair has been utilized: http://www.youtube.com/watch?v=r8MJrkzqRL0

• The test setup was simulated in a fully terminated configuration (differential mode)

with ideal differential generators at transmitter end

• The probe loading effects were simulated inserting the probe at the two line ends

Page 3: New Hi Safe Probe For 10+Gbps Fault Insertion

DIFFERENTIAL MICROSTRIP (OL1)

Page 4: New Hi Safe Probe For 10+Gbps Fault Insertion

Probe model

• The simulative model of the probe prototype has been extracted from 2 one-port TDR

measurements (50 ohm reference) on an actual prototype

• The model extraction and setup simulations have been performed using the DWS simulator

Page 5: New Hi Safe Probe For 10+Gbps Fault Insertion

DWS sim of the optimized Probe model (S11)

Page 6: New Hi Safe Probe For 10+Gbps Fault Insertion

DWS setup netlist (1)

Page 7: New Hi Safe Probe For 10+Gbps Fault Insertion

DWS setup netlist (2)

Page 8: New Hi Safe Probe For 10+Gbps Fault Insertion

DWS setup netlist (3)

Page 9: New Hi Safe Probe For 10+Gbps Fault Insertion

10Gbps Eye diagrams results (1)

Comparison between the unloaded net and the net with the probe connected at the drivers’s end

Page 10: New Hi Safe Probe For 10+Gbps Fault Insertion

10Gbps Eye diagrams results (2)

Comparison between the unloaded net and the net with the probe connected at the receiver’s end

Page 11: New Hi Safe Probe For 10+Gbps Fault Insertion

Preliminary conclusions (March 2010)

• New probe prototype loading performance is good for 10+Gbps Fault Insertion applications

• Loading effect on jitter at 10Gbps: less than 1ps

• Eye diagram amplitude reduction: 3.5 db