neTou User ude - Meissner Filtration Products · 214 essner ltraton roduts In. neTou ® SnleUse...
Transcript of neTou User ude - Meissner Filtration Products · 214 essner ltraton roduts In. neTou ® SnleUse...
1© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
2© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
Table of ContentsDisclaimer 3Trademark Information 3I. Safety 4
A. Intended Use 4B. SafetyAlertDefinitions 4
a. SignalWordsAccordingtoANSIZ535.6-2011 4b. SignalWordsAccordingtoISO3864 4
C. GeneralSafetyMessagesforSingle-UseAssemblies 5D. GeneralDeploymentandOperationalHazards 6
II. Part Number Genealogy 7A. StandardBiocontainerAssemblies 7B. CustomBiocontainerAssemblies 7C. ManifoldAssemblies 8D. BioFlex®FluidPathAssemblies 8
III. Inspection Upon Receipt 9A. GuidelinesforReceivingInspection 9
IV. Unpacking Your Biocontainer Assembly 10A. Pre-UseInspection 10B. GuidelinesforUnpacking 10
V. Deploying Your Biocontainer Assembly 12A. Pre-DeploymentInspection 12B. 2DEnd-PortedBiocontainerDeployment 12
a. HangingYourBiocontainer 12b. DeployingYourBiocontainerinaTrayorOtherSupportDevice 12c. FillingYourBiocontainer 12
C. 2DFace-PortedBiocontainerDeployment 13a. DeployingYourBiocontainer 13b. FillingYourBiocontainer 13
D. FlexFill®BiocontainerDeployment 14E. 3DBiocontainerDeploymentinRigidOuterContainers 16
a. 3DBiocontainerDeploymentinFlexStation®RigidOuterContainers 16b. 3DBiocontainerDeploymentinQuaDrum®RigidOuterContainers 25c. ThirdPartyRigidOuterContainer 26
VI. Operating Your Single-Use Assembly 27A. SupplementaryPackaging 27
a. VinylDustCaps 27b. BubbleWrapPoly-Bags 27c. TamperEvidentPoly-Bags 27
B. GeneralProcessConnections 28a. QuickConnectors 28b. LuerConnectors 29c. SanitaryFlangeFittings 30
C. ControllingFlow 31a. Clamps 31b. Valves 31
D. AsepticProcessConnections 32a. Single-UsetoSingle-UseAsepticConnections 32b. Single-UsetoMultiple-UseAsepticConnections 34
E. AsepticProcessDisconnections 35a. HFC39SeriesConnectors 35b. TubeSealers 35
F. EffectingFluidTransferofLiquids 35G. TakingSamples 36
a. SamplingandInjectionSites 36H. UseofFilters 37
a. OperatingInstructionsforFilters 37b. Pre-useIntegrityTesting 37c. Post-useIntegrityTesting 37
VII. Disposing of Your Biocontainer Assembly 38VIII. References 39IX. Appendices 40
A. SampleCaseandProductLabels 40
GD014-1.0
3© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
DisclaimerTheinformationinthisUserGuideisnotintendedtoencompassallfeasibleoperationalscenariosofthesingle-usecomponentsandsystemsdescribedhereingiventhevastarrayofdifferingapplications,usageparadigmsandmethodscontemplatedbypharmaceuticalendusers.
Theparticularapplication,methodsofuseandoperationalconditionsofsingle-usecomponentsandsystemsinyourprocessarebeyondourcontrol.Thus,itisimperativethatyoutestthesingle-usecomponentsandsystemsinyourspecificapplicationtodeterminetheirultimatesuitability.
ThecomponentsandproductslistedinthisUserGuidearedesignedforuseinpharmaceuticalandbiotechnologicalmanufacturingprocessesandarenottobeusedforanyhospitalorpatientcare.
Theinformationinthisdocumentissubjecttochangewithoutnotice.MeissnerFiltrationProducts,Inc.doesnotmakeanywarrantyorrepresentation,expressorimplied,withrespecttotheaccuracy,completenessorutilityoftheinformationcontainedinthisdocument.
TrademarkInformationAdvantaFlex® AregisteredtrademarkofNewAgeIndustriesAdvantaPureAseptiQuik™ AregisteredtrademarkofColderProductsCompanyBioFlex® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.C-Flex® AregisteredtrademarkofSaint-GobainPerformancePlasticsEverLUX® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.FlexCessory™ AtrademarkofMeissnerFiltrationProducts,Inc.FlexFill® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.FlexStation® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.FluoroFlex® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.I/P® AregisteredtrademarkofCole-ParmerL/S® AregisteredtrademarkofCole-ParmerMasterFlex® AregisteredtrademarkofCole-ParmerOne-Touch® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.Pharmed® AregisteredtrademarkofSaint-GobainPerformancePlasticsQuaDrum® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.Steam-Thru® AregisteredtrademarkofColderProductsCompanySteriLUX® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.STyLUX® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.TepoFlex® AregisteredtrademarkofMeissnerFiltrationProducts,Inc.
4© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
I. SafetyThankyouforchoosingassembliesfromourOne-Touch®single-usesystemsproductportfolio.
Thischapterprovidesimportantsafetyandcareinformation.Readthisguidebeforeusingthisproduct.Failuretofollowtheinstructionsandsafetyprecautionsinthismanualcouldresultinseriousinjuryordeath.Keepthisuserguideinasafelocationforfuturereference.MeissnerFiltrationProductsprovidesbothcustomerserviceandtechnicalsupport.
Torequestadditionalinformation,pleasecontact:NorthAmericaMeissnerFiltrationProducts,Inc.4181CalleTesoro Camarillo,CA93012USA
Phone:+18053889911Fax:+18053885948
Europe MeissnerFiltrationProductsGmbHAmKuemmerling24-2655294BodenheimGermany
Phone:+49613571695252Fax:+49613571691299
A. Intended UseTepoFlex®andFluoroFlex®biocontainerassemblies,aswellasBioFlex®fluidpathassemblies,fromourOne-Touch® single-usesystemsproductportfolioareintendedtobeusedforliquidmanagementapplicationsinpharmaceuticalandbiotechnologicalresearch,developmentandmanufacturingbyqualifiedpersonnelforinprocessuseonlyandarenottobeusedforanyhospitalorpatientcare.
B.SafetyAlertDefinitionsa. SignalWordsAccordingtoANSIZ535.6-2011
DANGERindicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNINGindicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTIONindicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.
NOTICEisusedtoaddresspracticesnotrelatedtophysicalinjury.
Safetyinstructions(orequivalent)signsindicatespecificsafety-relatedinstructionsorprocedures.
b. SignalWordsAccordingtoISO3864DANGER Signalwordusedtoindicateanimminentlyhazardoussituationwhich,ifnot
avoided,willresultindeathorseriousinjury.
WARNING Signalwordusedtoindicateapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION Signalwordusedtoindicateapotentiallyhazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.
GENERALWARNINGSIGNThegeneralwarningsignisusedtoalerttheusertopotentialhazards.Allsafetymessagesthatfollowthissignshallbeobeyedtoavoidpossibleharm.
5© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
C. GeneralSafetyMessagesforSingle-UseAssembliesANSI Z535.6 ISO 3864 Description
WARNINGDonotpressurize.Biocontainerassembliesarenotpressurerated.Biocontainerassembliesthatincludeafilterintheirupstreamfluidpathmustbeoperatedsoasnottopressurizethebiocontainer.
WARNINGDonotexceedmaximumoperatingtemperatureof60°Cor140°F.
WARNING Donotconstrictflowonthedownstreamsideofapumpduringoperation.Peristalticpumpscanintroducepressurecapableofcausingalossoffluidintegritywhenflowisrestricted.
CAUTIONDonotusesingle-useassembliesbelowminimumoperatingtemperatureof0°Cor32°F.Biocontainerassembliesthatarenotdesignedandqualifiedforfreeze/thawapplications,suchasforexamplethoserequiringtheuseofprotectiveouterrigidtraysorcontainers,mayresultinfluidintegrityfailures.Fluidpathassembliesthatarenotdesignedandqualifiedforfreeze/thawapplicationsmayresultinfluidintegrityfailures.
CAUTIONDonotpuncture.Single-useassemblieswhicharenotprotectedfromcontactwithsharpobjectsmayresultinfluidintegrityfailures.
CAUTIONDonotdrawvacuum.Single-useassembliesarenotratedforvacuum.
CAUTIONDonotoverfill.Biocontainersaredesignedwithamaximumoverageof10%oftheirstatednominalvolume when deployed under standard conditions.Exceedingthatlimitmayresultinfluidintegrityfailures.
6© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
D.GeneralDeploymentandOperationalHazardsANSI Z535.6 ISO 3864 Description
CAUTIONCuttinghazard.Boxcutterscancausedamagetoyoursingle-useassembly.
CAUTIONBursthazard.Donotexceedtheoperatingparametersforthespecificfilteryouareusing.Iftubingislocatedupstreamofthefilterdonotexceedoperatingparametersofthetubing.
CAUTIONFluidIntegrityhazard.Donotleanonanyrigidoutercontainerasthiscouldcauseawalltocollapseresultingindamagetoabiocontainerandpossibleinjury.Testanyhangingapparatusfirsttoensurethatitcansupporttheweightofafullbiocontainer.
7© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
II. PartNumberGenealogyA.StandardBiocontainerAssemblies
B.CustomBiocontainerAssemblies
8© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
C.ManifoldAssemblies
D.BioFlex®FluidPathAssemblies
9© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
III.InspectionUponReceiptSingle-useassembliesarepackagedintwocardboardboxes,i.e.,oneouterboxandoneormultipleinnerboxesforsecuretransportation.
TheCertificateofQualityisenclosedwithinthepackaging.Thesterilizingdosageinformationisavailableseparatelyfordownloadathttps://extranet.meissner.com/certificates.
A.GuidelinesforReceivingInspectionPlease refer to the following step-by-step guidelines: 1.Verifythatshippingdocumentationisingoodorder. 2.Inspecttheouterboxforpotentialshippingdamageandimmediatelyreportanydamagetothecarrier. 3.Opentheouterboxwithcautionasboxcutterscancausedamagetoyoursingle-useassembly. 4.Inspectinnerboxforpotentialshippingdamage. 5.VerifythattheCertificateofQualityisenclosedandreportanabsencethereofimmediatelytoMeissner. 6.VerifyCertificateofQualitywithCaseLabeloninnerbox.
AnannotatedsampleCaseLabelisfeaturedinAppendixA.TheCaseLabelwillonlyfeaturethecustomerpartnumberandcustomerpurchaseordernumberperspecificcustomerrequest.
7.Opentheinnerboxwithcautionasboxcutterscancausedamagetoyoursingle-useassembly. 8.Inspectsingle-useassembliesforpotentialshippingdamage. 9.VerifyCertificateofQualitywithProductLabel.
AnannotatedsampleProductLabelisfeaturedinAppendixA.TheProductLabelwillonlyfeaturethecustomerpartnumberandcustomerpurchaseordernumberperspecificcustomerrequest.Iftheproducthasbeenrequestedasnon-sterile,itwillbenotedassuchinlieuoftheirradiationdot.
10.Verifythequantityofsingle-useassembliesreceivedandimmediatelyreportanyshortfalltoMeissner.
10© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
IV.UnpackingYourBiocontainerAssemblySingle-useassembliesaremanufacturedinanISOclass7cleanroomandvaccuumpackagedintwopolyethylenebags.Thesingle-useassemblyissealeddirectlyinsidetheinnerpoly-bag,whichissealedinsidetheouterpoly-bag.Certainitemsmayincludeadditionalpackagingtoprovideprotectionduringshipment.FormoreinformationinthisregardseechapterVI.
Oncepackaged,single-useassembliesaregammairradiatedbeforebeingshippedunlessotherwiserequested.
Iftheproducthasbeenrequestednon-sterile,itwillbenotedassuchontheProductLabel.SeeAppendixAforreference.
A.Pre-UseInspectionPlease refer to the following step-by-step guidelines: 1.Removedesiredquantityofsingle-useassembliesfrominnerbox. 2.Verifythatthepackagingisingoodorder. 3.Recycleordiscardpackagingaccordingtolocalregulationsasappropriate. 4.VerifythattheexpirationdateontheProductLabelforeachsingle-useassemblyhasnotpassed. SeeAppendixAforreference.5.Recordthelotand/orserialnumberalongwithanyotherinformationthatyouneedforyourbatchrecordas
appropriate.Meissner’speelandsticklabel(whichislocatedontheoutsideoftheinnerbag)willsavetimeandhelptoeliminatehumanerrorintransferringdatatodocumentation.
B.GuidelinesforUnpackingPlease refer to the following step-by-step guidelines (continued on the next page):
Oftenafterremovingtheouterpoly-bagthesinglebaggedproductwillbetransferredtoacontroledspace,e.g.acleanroom,forsubsequenthandling.
Positionasafetycutterorothercuttingdevicesothatyouwillonlyopentheouterpoly-bag;carefullycutopentheouterpoly-bag.
Carefullyremovetheinnerpoly-bagfromtheouterpoly-bagandretainpeelandsticklabelforyourrecordsshouldyouchoosetodoso.
11© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
Positionasafetycutterorothercuttingdevicesothatyouwillonlyopentheinnerpoly-bag.Carefullycutopentheinnerpoly-bag,ensuringthatyoudonotdamageyoursingle-useassembly.
Younowhaveaccesstoyoursingle-useassembly.
Carefullyremoveyoursingle-useassemblyfromtheinnerpoly-bag.
12© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
V. DeployingYourBiocontainerAssemblyA.Pre-DeploymentInspection
1.Verifyclamppositionsandleavethemopenorclosethem,dependingonyourapplication.
Single-useassembliesarrivewithclampsopentopreventcompressionsetontubingthatmayhinderfunctionaldeploymentand/oroperation.
2.Verifythatalltubingendtreatmentsaresecuredasrequiredforyourapplication.
B.2DEnd-PortedBiocontainerDeployment2Dend-portedbiocontainersaredesignedtobeoperatedinahangingorpillowposition(eitherlayitflatoratthedesiredangle).Seefiguresbelowforexamples.
2Dend-portedbiocontainer 2Dend-portedbiocontainerinhangingpositionutilizingFlexCessory™cart&hanger
2Dend-portedbiocontainerinaflatpillowposition
2Dend-portedbiocontainerinangledpillowposition
a. HangingYourBiocontainerMeissner’sFlexCessory™dualend-portedbiocontainercartprovidessecuritywhendeployingend-portedbiocontainerassemblies.Thestandcansupportuptotwo20Lend-portedbiocontainersandisadjustable,viaacenterpostclamp,toaheightof72inches.BiocontainerassembliescanbedirectlysupportedonthenotchedheadofthecartorhungfromtheergonomicallydesignedstainlesssteelFlexCessory™hanger.
b. DeployingYourBiocontainerinaTrayorOtherSupportDeviceCarefullypositionbiocontainerinoronsupportdeviceandensurethattheportsonthecontainerareinthecorrectpositionforyourspecificapplication.
c. FillingYourBiocontainerOnceyourbiocontainerispositionedandsupported,decidewhichclampsshouldremainopenandwhichshouldbeclosed,andsubsequentlywhichprocessconnectionsneedtobeengagedbasedontheintendedapplication.SeeChapterVIformoreinformationregardingprocessconnections.
Fluidpathsshouldbepositionedtoenableunrestrictedtransferoffluidandshouldnotbeobstructedbythebiocontainer.
13© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
C.2DFace-PortedBiocontainerDeployment2Dface-portedbiocontainersaredesignedtobedeployedandoperatedinapillowposition(eitherlayitflatoratthedesiredangle).Supportdevicesincludethefollowingbutarenotlimitedto:labtables,shelves,trays,othersmooth,flatorslightlyangledsurfaces.Seethefiguresbelowforexampleswith2Dface-portedbiocontainers.
Forlarger2-Dface-portedbiocontainers(i.e.50-200L),cylindricaldrumscanoftenbeusedassupportdevices.ContactMeissnerifyouhavespecificquestionsinthisregard.
2-Dface-portedbiocontainer 2-Dface-portedbiocontainerinaflatpillowposition
2-Dface-portedbiocontainerinangledpillowposition
2-Dface-portedbiocontainersupportedbycylindricaldrums
a. DeployingYourBiocontainerEnsurethattheportsonthecontainerareinthecorrectpositionforyourspecificapplication.
b. FillingYourBiocontainerOnceyourbiocontainerispositionedandproperlysupported,decidewhichclampsshouldremainopenandwhichshouldbeclosed,andsubsequentlywhichprocessconnectionsneedtobeengagedbasedontheintendedprocessapplication.SeeChapterVIformoreinformationregardingprocessconnections.
Fluidpathsshouldbepositionedtoenableunrestrictedtransferoffluidandshouldnotbeobstructedbythebiocontainer.
14© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
D.FlexFill®BiocontainerDeploymentFlexFill®biocontainerassembliesaredesignedforapplicationsrequiringfastanddependableaseptictransferofliquidvolumeslessthanorequalto5L.Itslargescrew-capportallowsforrapidandconvenientfillinginanasepticenvironment(e.g.inalaminarflowhood)usingtheportablestainlesssteelFlexCessory™stand.
FlexFill®biocontainer FlexFill®biocontainersupportedonFlexCessory™stand
FlexFill®Mixingsystemshavebeenoptimizedforsmallvolumepowder-liquidandliquid-liquidmixingapplications.ThedistinctiveblendedshapeoftheFlexFill®biocontainerinconjunctionwiththeuniqueportinglocationsfeaturedonthemixingassembliesproviderobustmixingactionwhenusedwithasuitableperistalicpump.FlexFill®mixingassembliessupportasepticprocessingwhendeployedusingtheportablestainlesssteelFlexCessory™standinalaminarflowhoodorwhenspecifiedwithsterileand/orasepticfluidpathconnectionoptions.
Please refer to the following step-by-step guidelines (continued on the next page):
Decidewhichclampsshouldremainopenandwhichshouldbeclosed,andsubsequentlywhichprocessconnectionsneedtobeengagedbasedontheintendedprocessapplication.SeeChapterVIformoreinformationregardingprocessconnections.
PlaceFlexFill®biocontaineronthestandandadjusttoaccommodatescrewcapremovalandfilling.AdjustsupportpinsonstandsothatslackonthetopoftheFlexFill®isminimizedwithoutstretchingthefilm.
Thescrewcapishandtightenedtomaintainasepticconditionsandmayrequiremoderateforcetoremove.GraspacorneroftheFlexFill® biocontaineratthecrossseamwithonehandwhileturningthescrewcapcounter-clockwisewithyourotherhand.
Thefollowingshouldbecompletedunderalaminarflowhoodtomaintainasepticprocessconditions
15© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
FillyourFlexFill®biocontainerinaccordancewithyourinternalproceduresorpracticesregardingaseptichandling.
Ifthethreadsorsealingsurfaceoftheportbecomecontaminatedduringthefillingoperation,cleantheareawithanappropriateantimicrobialdisinfectantaccordingtoyourinternalproceduresorpractices.
Manuallyloosenthescrewcapbyturningitcounterclockwiseuntilitjustbreaksfreefromitsfrictionpoint.
Thissecondtighteningactioncompressesthescrewcaplinercreatingasealwhichis5to7timesstrongerthanasingletighteningalonewhileeliminatingtheneedforslipagentsorotherplasticadditives.
Manuallyinstallthescrewcapbyturningclockwiseuntilitseatsusingmoderateforce.
Immediately,andinthesamemotion,manuallyretightenthescrewcapusingmoderateforce.
16© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
IfusingaFlexFill®mixingassembly,deployrecirculationloopinaccordancewithyourinternalproceduresandpracticeswhileadheringtotheperistalticpumpmanufacturer’sinstructions.
Theuseoftubinginaperistalticpumpwhichiseitherincorrectlysizedand/ormanufacturedfrominappropriatematerial,canleadtoprematuretubingfailure.
E.3DBiocontainerDeploymentinRigidOuterContainersRigidOuterContainers(ROCs)offersupportfor3Dbiocontainersandlarger2Dface-portedbiocontainers.Seethefiguresbelowforexamplesof3DbiocontainerssupportedbyROCs.
3Dtopandbottomportedbiocontainer
3DbiocontainersupportedbyaFlexStation® ROC
3Dtop-portedbiocontainerdesignedfor
drumdeployment
3DbiocontainersupportedbyQuaDrum® on dolly
a. 3DBiocontainerDeploymentinFlexStation®RigidOuterContainers3Dbiocontainerscanbesuppliedwithtopand/orbottomports.Arigidoutercontainer(ROC)withbottomportingallowsforeasyproductdrainutilizinggravity,whereastopportedbiocontainerstypicallyrequireaperistalticpumptoevacuate.
100-500LFlexStation®ROC’shaveeitherafalsebottomorafalsewallforaccesstobottomportingandassociatedfluidpathstorage.
17© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
i.FlexStation®100and200
FlexStation® 100 and 200 Orientation for Biocontainer DeploymentITEM
1234567
DESCRIPTIONFrontWall-FrontoftheFlexStation®ROCBackWall-BackoftheFlexStation®ROCLeftSideWall-Theleft-handsideoftheFlexStation®ROCRightSideWall-TheRight-handsideoftheFlexStation®ROCFalseBottom-TheinnerbiocontainersupporttrayoftheFlexStation®ROC(notpictured)CollapsibleSupportFrame(notpictured)BottomDrainAccessDoor
Verify that your biocontainer and FlexStation® are compatible:1. 200LbiocontainerassembliesdesignedfortheFlexStation® are used only
withFlexStation®200units.2. 100LbiocontainerassembliesdesignedfortheFlexStation®100canbe
usedwitheithertheFlexStation®100or200.
18© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
3. TheFlexStation®canbeeasilyidentifiedbyitsnameplatebutcanalsobeverifiedbythedistancethatthefalsebottomislocatedfromtheflooroftheROC:
a. AFlexStation®200willhaveafalsebottomthatisapproximately4inchesfromthebottomoftheROCwhenerected.
b. AFlexStation®100willhaveafalsebottomthatisapproximately10inchesfromthebottomoftheROCwhenerected.
Prepare the FlexStation® to receive a biocontainer assembly: 1. RemovethelidfromtheROCanderectthewalls.2. Removetheplasticfalsebottom.3. Erectthefalsebottomrack.
a. LifttherackabovetheROCfloor.
b. RotatethelegsoutwardsothatthefeetcontactboththesideandtheflooroftheROC.
Step3ismosteasilyaccomplishedbyfirstrotatingthebacklegsoutwardsimultaneouslyandthen,whilerestingtherackonthebacklegs,rotatingthefrontlegsoutwardsimultaneously.
Falsebottomrackinplace Falsebottomtrayinplace
4. Reinsertthefalsebottomtray.
a. OrientthetraywiththesidespointedupandtheholeclosesttothefrontoftheROC(nearestthefalsebottomdoor).
b. Pressdownonthecornersofthefalsebottomtraytomakesurethetrayisseatedflatagainstthefalsebottomrack.
Orient and install biocontainer assembly:1. FlexStation®compatiblebiocontainerassembliesarepackagedina
rectangularformat.Whenopenedandlaidflat,theyformanoctagon.Thisoctagonhastwolongsideedgesthatarefourfilmlayersthick(identifiedasLeftandRightinbiocontaineroctagonfigure)andafrontandbackedgethataretwofilmlayersthickwithdiagonalcornersinbetween.
19© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
a. Theshortsidesofthebiocontainer(twolayersthick)willfoldupagainstthefrontandbackwallsoftheROC.
b. Thelongsidesofthebiocontainer(fourlayersthick)willmeettheleftandrightsidesoftheROCwhenlaidflatagainstthefalsebottom.
c. Oftheeightcornersoftheoctagon,thefourcornersthatarefourfilmlayersthickshouldmeeteachcorneroftheROCatthefalsebottom.
d. Notethesectionofthebiocontainer(layingflatintheFlexStation®
ROC)thatisonlytwofilmlayersthick.ThiswillappearasastripofmoretransparentmaterialrunningfromfronttobackoftheROC.Thebiocontainerportswillbecenteredfromlefttorightinthisstrip.
100Lor200LBiocontainerOctagon 100Lor200LBiocontainerinFlexStation®ROC
2. Ifatop-portedbiocontainerassemblyisbeinginstalled:
a. Installtheassemblypertheoctagonorientationmakingsurethatallportingisfacingup.
b. Verifythatnotubingistrappedbythebiocontainer.NotubingshouldberunningbetweentheROCwallsandthebiocontainer.
3. Ifatopandbottom-portedbiocontainerassemblyisbeinginstalled:
a. Locatethebottomport,whichisoffsettomeettheholeinthefalsebottomtray.
b. Routeallbottomtubing/fittingsthroughtheholeinthefalsebottomtrayandoutthefalsebottomdoor,takingcarenottostressthebiocontainerduringinstallation.
20© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
Tubingroutedthroughholeinfalsebottomtray
c. Completeinstallationofthebiocontainerassemblypertheoctagonorientationpreviouslydescribed.
d. Verifythatnotubingistrappedbythebiocontainer.NotubingshouldberunningbetweentheROCwallsandthebiocontainer.
Fill the biocontainer assembly:1. Forportingconnectionsonthetopofthebiocontainer,carefullyreachover
thefrontoftheROCforaccess.2. Thebiocontainermaybefilledfromeithertoporbottomports.
a. Thebiocontainerwillself-deployasitisfilled.
Fluidpathsshouldbepositionedtoenableunrestrictedtransferoffluidandshouldnotbeobstructedbythebiocontainer.
21© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
ii.FlexStation®500
FlexStation® 500 Orientation for Biocontainer DeploymentITEM
1234567
DESCRIPTIONFrontWall-FrontoftheFlexStation®500ROCBackWall-BackoftheFlexStation®500ROCLeftSideWall-Theleft-handsideoftheFlexStation®500ROCRightSideWall-TheRight-handsideoftheFlexStation®500ROCFalseBottom-TheinnerbiocontainersupporttrayoftheFlexStation®500ROCWallReleaseLatchesBottomDrainAccessDoor
Verify that your biocontainer and FlexStation® are compatible:1. Only500LbiocontainerassembliesareusedwithFlexStation®500units.2. TheFlexStation®canbeeasilyidentifiedbyitsnameplatebutcanalsobe
verifiedbytheinterior“footprint”or“base”dimensionsoftheROC:a. AFlexStation®500willbe102cmx72cm(40"x28").
3. Thebiocontainerassemblycanbeidentifiedbyitslabel.
Prepare the FlexStation® to receive a biocontainer assembly:
1. RemovethelidfromtheROCanderectthewalls.
a. Openthefrontwalllast,makingsuretheredlatchesaresecure.
22© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
2. Erectandlatchthefalsewall.
a. Thefalsewallwillbeleaningawayfromthefrontwall.
b. Movethetopofthefalsewalltowardthefrontuntilthewallclearsthestopblocksattheverybottomofthebin.
Erectingthefalsewall
c. Movethetopofthefalsewallbackawayfromthefrontuntilthereisenoughroomfortheupperlinkstorotateout.
d. Insertthelinksintotheirrectangularreceivers(boththeleftandrightlinksshouldbeinsertedsimultaneously).
e. Insertthedraw-latchpinsintotheirslotsandlatchlatches
Latchingthefalsewall
Thelatchesshouldsnapclosedwithonlylightpressure.Ifthelatcheswillnotclose,ordonotstayclosed,thedraw-latchpinsmayrequireadjustment.
23© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
Orient and install biocontainer assembly:
1. FlexStation®compatiblebiocontainerassembliesarepackagedinarectangularformat.Whenopenedandlaidflattheyformanoctagon.Thisoctagonhastwolongsideedgesthatarefourfilmlayersthickandaleftandrightedgethataretwofilmlayersthickwithdiagonalcornersinbetween.
a. Theshortsides(leftandright)ofthebiocontainer(twolayersthick)willfoldupagainsttheleftandrightwallsoftheROC.
b. Thelongsidesofthebiocontainer(fourlayersthick)willmeetthefrontandbacksidesoftheROCwhenlaidflatagainstbottom.
c. ThebackcornersofthebiocontainershouldbelocatedatthebottombackcornersoftheROC.
d. ThebiocontainerportswillbecenteredatthefrontoftheROCandwillmeetwiththebottomdrainreliefintheflooroftheROC.
500LBiocontainerOctagon 500LBiocontainerinFlexStation®ROC
2. Ifatop-portedbiocontainerassemblyisbeinginstalled:
a. Installtheassemblypertheoctagonorientationdescribedpreviouslymakingsurethatallportingisfacingup.
b. Verifythatnotubingistrappedbythebiocontainer.NotubingshouldberunningbetweentheROCwallsandthebiocontainer.
24© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
3. Ifatopandbottom-portedbiocontainerassemblyisbeinginstalled:
a. Locatewhichportyourorganizationhasdesignatedasthebottomportandverifythatthisportisfacingdown.
b. Verifythatnotubingistrappedbythebiocontainer.NotubingshouldberunningbetweentheROCwallsandthebiocontainer.
i. Ifastandardbiocontainerassemblyisused,thebottomportwillbeasinglelargerport.
i. Takecarenottostressthebiocontainerduringinstallation.
Tubingroutedthroughreliefinbottomoffalsewalland outtheaccessdoor
c. Completeinstallationofthebiocontainerassemblyperthepreviouslydecribedoctagonorientation.
Fill the biocontainer assembly:
1. Forportingconnectionsonthetopofthebiocontainer,carefullyreachoverthefrontoftheROCforaccess.
2. Thebiocontainermaybefilledfromeithertoporbottomports.
a. Thebiocontainerwillself-deployasitisfilled.
iii.AdditionalFlexStation®InformationFlexStation®1000ROC’sareavailableforbiocontainerassemblieswithvolumeslargerthan500L.PleasecontactMeissnerfordetailedproductinformation.
SupportandtransferofFlexStation®ROC’scanbeaccomplishedwithMeissnerFlexStation®specificmobilecartsorhandpallettruck.PleasecontactMeissnerfordetailedsupportproductinformation.
Fluidpathsshouldbepositionedtoenableunrestrictedtransferoffluidandshouldnotbeobstructedbythebiocontainer.
25© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
b. 3DBiocontainerDeploymentinQuaDrum®RigidOuterContainersPlease follow the step-by-step instructions:
Holdthebiocontaineratthetopandunfolditasshown.
Placethebiocontainer,topportsup,inthedrumwithtubingontheoutside.
Ifusingadolly,placethedrumondollybeforebiocontainerdeployment.
Positionthebiocontainersothatthefourgussetedcornersofthebiocontainerfitintothecornersofthedrum.
Whilefillingthebiocontainer,ensurethatplacementofthegussetedcornersissecureforapproximatelythefirstfiveliters.
Thebiocontainerisdesignedtoself-deployhoweverduetothehighaspectratiooftheQuaDrum®itisrecommendedtomonitorthefillingprocessandadjustthebiocontainerwhennecessary.
Decidewhichclampsshouldremainopenandwhichshouldbeclosed,andsubsequentlywhichprocessconnectionsneedtobeengagedbasedontheintendedapplication.
26© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
c. ThirdPartyRigidOuterContainersMeissnerFiltrationProductsdesignscustombiocontainersthatfitinthirdpartyrigidoutercontainerssuchasindustrystandardcylindricaldrums;however,itisultimatelythecustomer’sresponsibilitytocorrectlydeployourbiocontainersinthirdpartyoutercontainers.It’simperativethatcustombiocontainersaretestedfortheirspecificdeploymentanduse.
PleaseconsultMeissnerifyouhavefurtherquestionsregardingtheuseofthirdpartyROC’s.
27© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
VI.OperatingYourSingle-UseAssemblyA.SupplementaryPackaging
a. VinylDustCapsSomeendfittingsaresuppliedwithvinyldustcapsasaprecaution.Forexample,manysimpleLuerend-fittingsandsomeTCconnectionsutilizethese.Simplyremovethedustcapwhenaccesstoagivenconnectionisrequired.
Single-useassembliesmayincludesupplementarypackagingitemstoprovidetamperevidenceand/oradditionalprotectionduringshipment.Thethreemostcommontypesofsupplementarypackagingareidentifiedbelowhoweverthisisnotanexhaustivelist.PleaseconsultMeissnerifyouhaveanyquestionspertainingtosupplementarypackagingnotcoveredhere.
b. BubbleWrapPoly-BagsFiltersandlongerfluidpathswithbulkycomponentryareoftenplacedinsealedbubblewrappoly-bagstoprovideadditionalprotection.Thesecaneasilyberemovedduringdeploymentoftheassociatedsingle-useassembly.
c. TamperEvidentPoly-BagsQuickconnectors,asepticconnectorsandsomeothertubingend-treatmentsmayincludetamperevidentre-closablepoly-bagssecuredwithacabletie.Togainaccesstotheprocessconnectionsimplyremovetheperforatedtamperevidentplasticstripandopenthepoly-bagviathere-closableseal.Thepoly-bagcanbepushedbackawayfromthefluidpathandtheconnectionthenmade.
28© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
B.GeneralProcessConnectionsa. QuickConnectors
Quickdisconnectcouplings(QDC’s)arecommonlyusedtoaccomplish1/4"–1/2"innerdiametertubingconnections.Thesearenotconsideredasepticconnectors,howevertheycanbeoperatedasepticallygiventheproperenvironmentandtechnique.TherearetwogeneraltypesofQDC’s;MPCfittingsaccommodateflowpathsbetween1/8"and3/8"innerdiameterwhileMPXfittingscanbeusedwith3/8"and1/2"innerdiameterflowpaths.
Tomakeaconnection,simplypushthecouplinginsertintothecouplingbodyuntilyouhearanaudible“click”.
QDC’saredeliveredwithcapsorplugstocloseoff thefluidpath.
Whenreadytomakeaconnection,ensurethatfluidflowisrestrictedaccordinglyandremovecapandplugaccording
toyourinternalproceduresandpractices.
Todisconnect,ensurethatfluidflowisrestrictedaccordinglyanddepresswhitelatchoncouplingbodyto
pullcouplinginsertout.
29© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
b. LuerConnectorsLuerconnectorsaretypicallyusedforsamplingoperationsandsmallvolumefluidtransferapplications.
Luerconnectorsaredeliveredwithcapsorplugstocloseoffthefluidpath.
Whenreadytomakeaconnection,ensurethatfluidflowisrestrictedaccordinglyandremovecapandplugaccording
toyourinternalproceduresandpractices.
Tomakeaconnection,holdoneconnectorwithyourlefthandandturnoppositeconnectorclockwisewithyourright
hand.
Todisconnect,ensurethatfluidflowisrestrictedaccordinglyandholdoneconnectorwithyourlefthandandturnoppositeconnectorcounter-clockwisewithyourright
hand.
30© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
c. SanitaryFlangeFittingsSanitaryflangefittingsareoftenusedasaconnectionbetweensingle-usesystemsandtraditionalprocessingequipment.Theyaresuitableforhighpressureapplicationswhenusedinconjunctionwithhighpressuretubingandhighpressurehosebarbconnectivity.
Sanitaryflangefittingscanbedeliveredwitheitheravinyldustcaporsecuredwithablindcap,gasketandclamp.Toconnecttwosanitaryflangefittingsyou’llneedonegasket
andoneclamp.
Whenreadytomakeaconnection,ensurethatfluidflowisrestrictedaccordingly,removeanyprotectivecoveringandplacesiliconegasketintoridgeononesanitaryflange.
Connecttheflangestogetherwiththegasketbetweenthem.
Applyclamparoundtheoutsideoftheflangesandtightenthebutterflyscrewbyturningitclockwise.Toremove
clamp,turnbutterflyscrewcounter-clockwise.
31© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
C.ControllingFlowa. Clamps
Ratchetingpinchclampsarecommonlyusedforcontrollingfluidflowandarecompatiblewithmoststandardtubing.
Torestrictorstopfluidflow,pinchclamptogether.
Toallowfluidflow,openclampbypullingbottomofclampsothatratchetisreleasedandpullboth
endsasshown.
b. ValvesSingleusevalvescanbeusedasclampstoshutofffluidfloworasvalvestocontrolflowrates.ForhighpressureapplicationsMeissnerrecommendstheuseofheavydutyvalvesliketheoneinthefiguresbelowinconjunctionwithbraidreinforcedsiliconetubing.
Torestrictorstopfluidflow,tightenbutterflyscrewbyturningclockwise.
Toallowfluidflow,loosenbutterflyscrewbyturningcounter-clockwise.
32© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
D.AsepticProcessConnectionsa. Single-UsetoSingle-UseAsepticConnections
i.AsepticConnectors
AseptiQuik™connectorsaredeliveredwithprotectivecaps.Removethesecapswhenreadytomakeanaseptic
connection.
Ensurethatfluidflowisrestrictedaccordingly.Lineupbluetabsandclickthecouplinginsertintothecouplingbody.
Pullbluemembranetabsouttogether. Holdcouplingbody(whiteconnection)inplaceandtwistcouplinginsertbluecollarclockwiseuntilyouhearaclick.
TherearetwogeneraltypesofasepticconnectorsthatMeissnerrecommends;AseptiQuik™connectors,whichutilizeacouplinginsertandacouplingbody,andAseptiQuik™Gconnectors,whicharegenderless.Alternatively,tubewelderscanbeusedtomakeasepticprocessconnections.
FormoreinformationabouttheAseptiQuik™refertotheColderProductsCompany®websiteat www.colder.com.
33© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
FormoreinformationabouttheAseptiQuik™GrefertotheColderProductsCompany®websiteat www.colder.com.
iii.TubeWeldersTubeweldersareusedtoasepticallyconnectthermoplasticelastomer(TPE)orPVCtubingmaterials.Tubingthatisspecifiedtobeweldedwilltypicallyterminatewithahosebarbplugorasealedend.Refertoyourtubeweldermanufacturerforsafetyinformationanduserinstructions.
ii.GenderlessAsepticConnectors
AseptiQuik™Gconnectorsaredeliveredwiththeirbluemembranepulltabscoveringtheconnections.
Whenreadytomakeanasepticconnection,ensurethatfluidflowisrestrictedaccordinglyandopentabssothat
theylineup.
Clicktheconnectionstogether. Pullbluemembranetabsouttogether.
34© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
ProcessFlowDiagramforSteam-Thru®
b. Single-UsetoMultiple-UseAsepticConnectionsi.Steam-Thru®Connectors(STC’s)
1. Tosterilizetheconnection,allowsteamtoflowfromtheprocessequipmentthroughtheSTCintoasteamtrap.
2. Removeprotectivesleevewhenreadytodisconnectfromthesteamtrapandpushtogethertoactuate.
ProcessFlowDiagramforSteam-Thru® II
1. Tosterilizetheconnection,allowsteamtoflowfromtheprocessequipmentthroughtheSTCIIintoasteamtrap.
2. Removeprotectivesleevewhenreadytodisconnectfromthesteamtrap.Depresslatchandpushtogethertoactuate.TheSTCIIisnowinthe“flowposition.”
4. Toreturnto“sterilizationposition”,depresslatchandmovevalvebackuptooriginallocation.
Establishflowbetweenprocessequipmentandsingleusesystem.3.
Establishflowbetweenprocessequipmentandsingleusesystem.3.
FormoreinformationaboutSteam-Thru®andSteam-Thru®IIconnectorsrefertotheColderProductsCompany®websiteatwww.colder.com.
ii.Steam-Thru®IIConnectors(STCII’s)
35© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
E.AsepticProcessDisconnectionsa. HFC39SeriesConnectors
TheHFC39seriesconnectorsaredesignedtoshutofftheflowpathwhendisconnected,providingsingle-useasepticdisconnectfunctionality.Theseconnectorsaredesignedforsingleactuation;i.e.donotreconnectthem.
HFC39seriesconnectorsaredeliveredconnected,ensuringsterility.
Whenreadytomakeanasepticdisconnection,depressthumblatchandpullconnectorsapart.
DonotreconnectonceHFC39connectorshavebeendisconnected.
b. Tube SealersTubesealersareusedtoasepticallydisconnecttubing.TPEtubingcanbesealedwiththermalequipment.PVCandEVAtubingcanbethermallysealedorRFwelded.Refertoyourtubesealermanufacturerforsafetyinformationanduserinstructions.
F. EffectingFluidTransferofLiquidsThetwomostcommonmethodsofaffectingafluidtransferto,from,orthroughasingle-usesystemareviagravityandviatheuseofaperistalticpump.Typicallyperistalticpumpsrequirespecificsizetubinginordertofunction.Anabbreviatedtableisprovidedbelow.However,pleaseconsultyourpumpmanufacturer’soperatingmanualforspecifictubingsizeandmaterialrecommendations.
Theuseoftubinginaperistalticpumpwhichiseitherincorrectlysizedand/ormanufacturedfrominappropriatematerial,canleadtoprematuretubingfailure.
Peristaltic Pump Tubing Sizing ChartTubing Size Masterflex® Watson Marlow
ID x OD Number L/S® High Performance I/P® Precision 520R 520R2 620R1/8"x1/4" 16 x3/16"x5/16" 25 x3/16"x3/8" 15 x x1/4"x3/8" 17 x1/4"x7/16" 24 x x1/4"x1/2" 26 x x3/8"x9/16" 36 x3/8"x5/8" 73 x x1/2"x3/4" 82 x x
FormoreinformationaboutHFC39seriesconnectorsrefertotheColderProductsCompany®websiteatwww.colder.com.
36© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
G.TakingSamplesa. SamplingandInjectionSites
Therearemultiplesamplingandinjectionoptionsavailable.Meissnertypicallyrecommendsswabablevalvesorneedlefreeconnectors,whicharedesignedassamplesitesthatcanbeutilizedwithoutaneedle.Firstswabthesiliconesealthenconnectamaleluersyringetotakeasampleaccordingtoyourinternalproceduresorpractices.
i.SwabableValve/NeedlelessInjectionSite
ii.NeedleFreeConnector
Swabablevalvesaredeliveredwithaprotectivecap.Whenreadytomakeaconnection,removecap.
Connectmaleluersyringetovalve. Takesampleoraddtosingle-usesystemaccordingtoyourinternalproceduresorpractices.
NeedleFreeconnectorsaredeliveredwithaprotectivecap.Whenreadytomakeaconnection,
removecap.
Connectmaleluersyringetovalve. Takesampleoraddtosingle-usesystemaccordingtoyourinternalproceduresorpractices.
FormoreinformationabouttheClave®NeedleFreeConnector,refertotheICUMedicalwebsiteatwww.icumed.com.
FormoreinformationabouttheswabablevalverefertotheHalkey-RobertsCorporationwebsiteat www.halkeyroberts.com.
37© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
1. Securetheinletandoutletofthefilterasrequiredbythesingle-useassemblydesignanditsusage.
2. Slowlyinitiateflowthroughthefilter.
Filterwithhosebarbsoninletandoutlet Filterwithsanitaryfittingsoninlet and outlet
3. Ifventingisnecessary,positionthefiltersotheventopeningpointsupwardandslowlyopenthevent.Continuetoventuntilliquidexitstheventorallairisexpelled.
4. Graduallyincreasethepressureorflowratetothevaluequalifiedbyyourinternalprocedures.
5. Monitorthefilterduringtheprocessforpressurebuildupandventasnecessary.
6. Whenfiltrationiscompletestopflowtofilter.
7. Inthecaseofafluidfiltrationprocessstep,filter(s)willgenerallyneedtobeasepticallydisconnectedfromthedownstreamprocesswithin8hoursoffiltration.
Refertofiltermanufacturer’stechnicaldatasheetsforfilterspecificinformation.MeissnerFiltrationProductsprovidesfilterdatasheetscalled,“GreenDocs”atwww.meissner.com.
b. Pre-useIntegrityTestingCertainsingle-usesystemscanbedesignedtoaccommodatepre-useintegritytestingfunctionality.Thespecificationsforpre-useintegritytestsvarydependingontheassemblyandtypeoffilter.PleasecontactMeissnerTechnicalServicesformoreinformation.
c. Post-useIntegrityTestingDisconnectfiltersfromthesingle-useassemblyandpost-useintegritytestaccordingtoyourinternalproceduresandpracticesandthefilterspecifications.PleasecontactMeissnerTechnicalServicesformoreinformation.
H.UseofFiltersa. OperatingInstructionsforFilters
Thefollowinginstructionsarefairlybroadastherearemanydifferenttypesandconfigurationsoffilters.MorespecificusageinstructionsforMeissnerfilterscanbedownloadedbyselectingthecorrespondingfilterGreenDocatwww.meissner.com/greendocs.YoucanalsocontactMeissnerTechnicalServicesformoreinformationandassistance.
38© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
VII.DisposingofYourBiocontainerAssemblyTherearevariousdisposaloptionsforbiocontainerassemblies.Basedonyourinstitution’sproceduresandpracticesandcompliancewithlocalregulations,theappropriatemethodofdisposalshouldbedetermined.
39© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
VIII.References1. MeissnerFiltrationProducts,Inc.(2009)“One-Touch®BiocontainerDeployment
forFlexStation®100-200ROCs”,TechnicalBulletin(TBOT06),November2009.
2. MeissnerFiltrationProducts,Inc.(2010)“One-Touch®BiocontainerDeployment–FS0500”,TechnicalBulletin(TBOT07),October2010.
3. MeissnerFiltrationProducts,Inc.(2011)“One-Touch®FlexFill®DeploymentandCapInstallation”,TechnicalBulletin(TBOT09),August2011.
4. MeissnerFiltrationProducts,Inc.(2012)“One-Touch®DualBiocontainerStand&Accessories”,TechnicalBulletin(TBOT10),March2012.
5. MeissnerFiltrationProducts,Inc.(2012)“One-Touch®QuaDrum®”,TechnicalBulletin(TBOT12),March2012.
40© 2014 Meissner Filtration Products, Inc. - One-Touch® Single-Use Systems User Guide
One-Touch® User Guide
A.SampleCaseandProductLabels
Case Label
ProductLabel
IX.Appendices