Nemo Scanner Guide_July11

download Nemo Scanner Guide_July11

of 119

  • date post

    27-Oct-2014
  • Category

    Documents

  • view

    739
  • download

    0

Embed Size (px)

Transcript of Nemo Scanner Guide_July11

SCANNER GUIDE

Version 6.00

2011 by Anite Finland Ltd. All rights reserved. This manual, as well as the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. The information in this manual is intended for informational use only and is subject to change without notice. Anite Finland Ltd assumes no responsibility or liability for any errors or inaccuracies that may appear in this user manual. Except as permitted by such license, no part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Anite Finland Ltd. Windows, Windows XP, Windows Vista, Windows 7, Outlook, and Internet Explorer are registered trademarks of the Microsoft Corporation in the United States and other countries. MapInfo and MapX are registered trademarks of MapInfo Corporation. CDMA 2000 is a registered trademark of the Telecommunications Industry Association (TIA -USA). The license management portion of this Licensed Technology is based on SentinelLM* 1989-2003 Rainbow Technologies, Inc. All rights reserved.

Revision 6.00.01, Last edited July 2011

NEM O SCA NNER G UI DE

3

CONNECTING DEVICES Connecting Nemo FSR1 Scanner Connecting Anritsu Scanners Connecting the DRT Wimax 4301A+ Scanner 4 4 8 17 20

Connecting the PCTEL LX CDMA/EVDO/GSM/WCDMA Scanner Connecting PCTEL EX scanners 22

Connecting the PCTEL LX GSM/WCDMA Dual-Mode Scanner Connecting the PCTEL MX GSM/WCDMA Scanner Connecting PCTEL PCT Scanners 29 32

26

Connecting the Rohde & Schwarz TSMQ/TSML Scanner 35 Connecting the Rohde & Schwarz TSMW Scanner STARTING DEVICES Starting Nemo FSR1 Scanner Starting Anritsu Scanners Starting DRT Scanners Starting PCTEL Scanners Starting Rohde & Schwarz Scanners STARTING MEASUREMENT Nemo FSR1 Scanner Anritsu Scanners PCTEL Scanners DRT Scanners Rohde & Schwarz TSMQ/TSML/TSMW Scanners TROUBLESHOOTING SCANNERS 39 43 43 45 47 49 55 56 56 67 81 102 107 119

NEM O SCA NNER G UI DE

4

CONNECTING DEVICESCONNECTING NEMO FSR1 SCANNERNemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is achieved by using the optional AC power supply. The AC power supply is designed to work with 100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct supply.

The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending number of downconverters installed and the receiver tasking. The maximum power requirement of the scanner is 50 Watts. DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt system. The following table is provided to budget the system current requirements for various configurations. Platform configuration/Module Basic system w/ single downconverter Two downconverter system 12 VDC current requirement 3.0 A 3.6 A

The estimates given for the scanner assume maximum utilization of the processing capabilities.

Connecting the Nemo FSR1:1. Connect an antenna cable to scanner RF input. If you are measuring with two downconverters, connect an antenna in both RF inputs (see picture below).

NEM O SCA NNER G UI DE

5

2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo Outdoor laptop. 3. Go to Control Panel | Network and Internet | Network and Sharing Center. Click on Change adapter settings.

4. Right-click on Local Area Connection and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol Version 4 (TCP/IPv4) and click Properties.

NEM O SCA NNER G UI DE

6

5. Select Use the following IP address and type in the IP address of the scanner in the IP address field. Click OK and Close.

Please note that by default the Nemo FSR1 is delivered with a fixed IP address. The IP address can be changed with a separate utility software. The following IP addresses are used in Nemo Outdoor: "Nemo Scanner LAN" = 192.168.3.253 "Nemo Scanner LAN 2" = 192.168.3.252 "Nemo Scanner LAN 3" = 192.168.3.251 "Nemo Scanner LAN 4" = 192.168.3.250

6. Connect the power cable to the scanner and to a power source. Switch power on. Fuse Fans

Power connector

Power switch

NEM O SCA NNER G UI DE

7

7. The default address and name settings of the scanner are generally suitable for most users. There is no need to configure these settings when using the Nemo FSR1 scanner with Nemo Outdoor. 8. The status LEDs at the front panel display how the scanner is functioning. LED Name RxA RxB Status Active All LEDs LED Color Green Amber Green Amber Green Amber Green Red Amber Description Receiver A enabled Receiver A disabled i.e. EEPROM not readable Receiver B enabled Receiver B disabled i.e. EEPROM not readable GPS Locked GPS Unlocked Ethernet link connected Ethernet link disconnected If all four LEDs are amber, the bootloader is running and the module needs to be reloaded

NEM O SCA NNER G UI DE

8

CONNECTING ANRITSU SCANNERS These instructions apply to all Anritsu scanners, except Anritsu MS2721B DVB-H Analyzer. 1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-mode scanner that supports both GSM and WCDMA, use the RF1 input (see picture). RF2 input only supports WCDMA scanning.

2. Connect the battery cable to the battery and to a power source.

3. The Battery led of the scanner should turn green. The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.

NEM O SCA NNER G UI DE

9

4. Connect the null modem cable to the scanner COM port that can be found below the power switch.

5. Connect the null modem to one of the PC COM ports 6. Turn the power on in the scanner. The Power led should light up. 7. The scanner should now start, wait until the scanner has started 8. Press the Menu button in the scanner. 9. Use the arrow keys and the Sel button to select Interface and Behavior. 10. Check that the settings are as follows. If not, change them using the arrow keys and the Sel button (note that the selected item will be underlined as soon as you use the arrow buttons to switch to another line). To exit the dialog without saving, press the F4 button (Cancel). To exit the dialog and save the modified settings, press the F5 button (OK). COM1 Protocol: Direct COM1 Baud Rate: 38400 or 57600 or 115200 COM1 Stop Bit(s): 1 COM1 Data Length: 8 COM1 Parity: None

The baud rate 115200 is the fastest option. Note! Memorize the baud rate. It is needed when starting the device. 11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see the following steps.

NEM O SCA NNER G UI DE

10

12. Insert the Anritsu installation CD in your PC. 13. Connect the USB cable to the scanner USB port found in the front panel and to the PC. 14. Switch the scanner on. 15. The New Hardware Wizard will start automatically. Select the No, not this time option and click Next.

16. Select the Install the software automatically option and click Next.

NEM O SCA NNER G UI DE

11

17. If a warning message appears, click Continue Anyway. The installation will start. Please wait while the New Hardware Wizard installs the software. When the installation is complete, click Finish.

18. To check that the installation was successful, go to Device Manager (Start | Settings | Control Panel | System | Hardware | Device Manager). Expand the Universal Serial Bus controllers item. Area Scanner should be on the list.

NEM O SCA NNER G UI DE

12

19. Double-click on Area Scanner. Check that the Device Status field displays This device is working properly. Exit the dialog by clicking OK.

Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer Scanner Installing the driver:Please follow the following steps to install the NI-VISA 4.0 driver. 1. To install the driver the user must have administrative rights to its PC, and the Take ownership of files or other objects policy has to be enabled for this user on this PC. 2. Copy the executable file visa400full.exe to your local drive before installing the driver, and run the installation from the hard drive.

NEM O SCA NNER G UI DE

13

3. Double-click on the file and unzip the contents to your hard-drive. This may take a couple of minutes.

4. The installation starts automatically. 5. Click Next>> on the welcome page.

NEM O SCA NNER G UI DE

14

6. Select the destination folder for the driver and click Next>>.

7. Click Next>> in the Features dialog.

8. Select I accept the License Agreement(s) in the following page and click Next>>. 9. Click Next>> in the following dialog and wait for the installation to finish, and Finish in the Installation Complete dialog. Note that you may need to restart your computer for the installation to take effect.

NEM O SCA NNER G UI DE

15

10.Connect the scanner with your PC through a network cable. Insert one end of the network cable in the network cable connector in the scanner, and the other end to the network cable connector in your PC.

11.Next, you need to make some changes to your PCs network card properties. Go to Start | Control Panel | Network Connections, and right-click on Local Area Connection, and select Properties. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use the following IP address. You need to type in an IP address out of the