nectas1641-1651-100224044512-phpapp02

19
PRÁTICA NECTAS 1641-1651 ACESSAR O NECTAS USUÁRIO – ADMIN SENHA – ADMIN BELL > DISABLE BACKUP 1641 – SM SALVAR: EQUIPAMENT CONFIGURATION CONNECTION CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES 1651 – SM SALVAR: EQUIPAMENT CONFIGURATION CONNECTION CONFIGURATION WITH FULL MATRIX CONNECTION CONFIGURATION WITH VC4 MATRIX DROP SHELF CONNECTION CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES (SE HOUVER DÚVIDA SALVAR TUDO) OBS: ONDE TIVER DROP SHELF NÃO PRECISA SALVAR (1641 SMD), NO 1651 VAI ESTAR A MATRIX FULL OU A VC4. DROP SHELF É UM SUB BASTIDOR DO 1641 ASSOCIADO AO 1651. O 1651 É EQUIPADO ATÉ 1 STM1, COM O DROP SHELF ESSA CAPACIDADE É AMPLIADA COM 3 STM1, FICANDO ATÉ 4 STM1. EXECUTANDO BACKUP ABRIR ELEMENTO DE REDE (DUPLO CLICK) EQUIPAMENT CONFIGURATION > FILE > RECIVE DIGITAR DADOS DA ESTAÇÃO > OK

Transcript of nectas1641-1651-100224044512-phpapp02

Page 1: nectas1641-1651-100224044512-phpapp02

PRÁTICA NECTAS 1641-1651

ACESSAR O NECTAS

USUÁRIO – ADMINSENHA – ADMIN

BELL > DISABLE

BACKUP

1641 – SM SALVAR:EQUIPAMENT CONFIGURATIONCONNECTION CONFIGURATIONLOCAL CONFIGURATIONROUTING TABLES

1651 – SM SALVAR:EQUIPAMENT CONFIGURATIONCONNECTION CONFIGURATION WITH FULL MATRIXCONNECTION CONFIGURATION WITH VC4 MATRIXDROP SHELF CONNECTION CONFIGURATIONLOCAL CONFIGURATIONROUTING TABLES

(SE HOUVER DÚVIDA SALVAR TUDO)

OBS: ONDE TIVER DROP SHELF NÃO PRECISA SALVAR (1641 SMD), NO 1651 VAI ESTAR A MATRIX FULL OU A VC4.DROP SHELF É UM SUB BASTIDOR DO 1641 ASSOCIADO AO 1651. O 1651 É EQUIPADO ATÉ 1 STM1, COM O DROP SHELF ESSA CAPACIDADE É AMPLIADA COM 3 STM1, FICANDO ATÉ 4 STM1.

EXECUTANDO BACKUP

ABRIR ELEMENTO DE REDE (DUPLO CLICK)EQUIPAMENT CONFIGURATION >FILE > RECIVEDIGITAR DADOS DA ESTAÇÃO > OKCONNECTION CONFIGURATIONFILE > RECIVEDIGITAR DADOS DA ESTAÇÃO > OKLOCAL CONFIGURATIONFILE > RECIVEDIGITAR DADOS DA ESTAÇÃO > OKROUTING TABLESFILE > RECIVE

Page 2: nectas1641-1651-100224044512-phpapp02

DIGITAR DADOS DA ESTAÇÃO > OK

PARA SALVAR EM OUTRA PASTA

IR ATÉ A PASTA C: ALCATEL /1641 SM 27 OU 1651 SM 25 (COPIA PARA A PSTA DA ESTAÇÃO SEM AUTERAR O ARQUIVO)

TROCAR SMEC

1 2 DIP SWITCH ON OFF POSIÇÃO NORMALOFF ON POSIÇÃO LIMPEZA DE BANCO DE DADOSOFF OFF RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS,

LAPD, ETHERNET).ON ON RETAURAR O BANCO DE DADOSON OFF POSIÇÃO NORMAL

PASSOS:

PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON – INSERIR A PLACA E AGUARDA O LED ABN ACENDER. (O BANCO FOI LIMPO).PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON – INSERIR A PLACA, AGUARDA O LED ABN ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION).PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON – INSERIR A PLACA, AGUARDA O LED ABN ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE).PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF – INSERIR A PLACA, AGUARDA O LED ABN ACENDER.

PARA RESTORE

FILE SEND (SELECIONA ARQUIVO DA ESTAÇÃO E CLICA OK)

SEQUENCIA DE TABELAS:CONNECTION CONFIGURATIONEQUIPMENT CONFIGURATIONLOCAL CONFIGURATIONROUTING TABLESDEMAIS TABELAS

INSERIR NA GERÊNCIA

LAPDETHERNET CONFIG (Só para cne´s)

Page 3: nectas1641-1651-100224044512-phpapp02

1- LAPDABRIR ELEMENTO DE REDE (DUPLO CLICK)CLICA EM LAPD CONFIGURATION >AGRR STMI E1 (USER) >AGRR STM1W1 (NETWORK)LOCAL CONFIGURATION > YES > NETWORKTABLES > MS LAPD CONFIGURATIONE1 > W12 – ETH > YES > FALSE (L2 ONLY)3 – OS ADRESSINSERIR NSAP DA GERÊNCIANO NO4 – NE ADRESS (LOCAL CONFIGURATION)INSERIR NSAP E 7.1 (ADRESS DO NE)SISTEM ID (EX 002060222222)7.1 = 8FILE > SAVE > FILE > SEND.OBS-SE HOUVER MUDANÇA DO NSAP, O SISTEMA EXECUTA REBOOT. É NECESSÁRIO CONECTAR NOVAMENTE.

ACESSO REMOTO

1 – DECLARAR NO MEU ELEMENTO DE REDE, OS NSAP´S QUE QUERO VER REMOTAMENTE.

LOCAL / CONFIG > R-ECTYES (MARCA)DIGITA NSAP E 7.1 ADRESS DOS NE´S REMOTOS.CLICA EM NEXT PARA CRIAR OUTRO NE.FILE > SAVE > FILE > SEND.

FECHAR O NECTAS

2 – MENU INICIAR

>PROGRAMAS > ALCATEL > NETWORK CONFIG>NETWORK CONFIGURATION>NETWORK > CREATE > DEFAUT > NETWORK NAME (GENERAL) > CREATE

3 – ABRIR PAINT BRUSH PARA CRIAR UM FUNDO, QUE SERÁ INSERIDO NA REDE (GENERAL).

Page 4: nectas1641-1651-100224044512-phpapp02

FAÇA UM “COPY” NO PAINT BRUSH E UM “MAP > PASTE” NO MAPA GENERAL.4 – CRIAR UM NE GENÉRICO QUALQUEREQUIPAMENT > CREATE > ME (0) > SECONDARY ADRESS (5) > CREATE

BOTÃO ESQUERDO > LOCATE EQUIPAMENT > LOCALIZE

5 – EDITAR WIN INIIR A C: / WINT / WIN.INI E EDITAR COM OS DADOS:[ PEX ]COMPEX=COM1:PEXLOAD=12TimRetrasmiis=20sec12TimPolling=4sec12TimResponse=5sec12Retry=1NETCFG_RECT=YESNETCFG_NETWORK=C:/NETWORK/REDE/TXTPATH=C:NETWORK/REDE/TXTFILE/NETWORK_RF=REDENETPATH=C:/NETWORK/REDE/NETFILE/WMFPATH=C:/NETWORK/REDE/WMFILE/NETWORK=REDEOBS-CASO O NOME DO MAPA SEJA GENERAL, SUBSTITUIR A PALAVRA REDE POR GENERAL.

6 – ABRIR O NECTAS

VIW > NETWORK (Aparecerá todos os elementos criados)OBS-de 2 a 5 é a configuração do Laptop

VIW > SUB NETWORK / EQUIPAMENTS ( duplo click)ALARMS E STATUS > OK

CROSS CONEXÃO

CRIANDO CIRCUITO DE 2 MBABRE O NE (duplo click)CONNECTION CONFIGURATION > OKFILE > RECIVE > SELECIONA ESTAÇÃO > OK (Salva)TABLE > PAYLOAD STRUTURE AND SIGNAL LABEL > OKTABLE > TU-12´S ALLOCATION FOR 21X2M/SCDMA TRIBUTARY > OKEQUIPA O TRIBUTÁRIOEQUIPA O TU12 (CRIAR CORRESPONDENCIA COM O LADO REMOTO)EQUIPA O MODE (D / I BIDI UNP E OU W (E OU W DE ACORDO COM O PROJETO, UM LADO E O OUTRO W)).

Page 5: nectas1641-1651-100224044512-phpapp02

FILE > SEND > SAVE > SEND

OBS= NO LADO REMOTO DEVE SE FAZER O MESMO PROCESSO1641, 1651, 1664 SÓ DOIS AGREGADOS.

FAZER LOOP 2MB

ABRE O NE (duplo click)CLICA ALARMES, STATUS AND REMOTE CONTROLS > OKCLICA LOGIC > T2M 1 (PLACA DE TRIBUTÁRIO PRINCIPAL)CLICA NO TRIBUTÁRIOCLICA REMOTE_CONTROLCURRENT DISPLAYENABLE INT LOOP 2M (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTOENABLE LINE LOOP 2M (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO

FAZER LOOP DE AGREGADO

ABRE O NE (duplo click)CLICA ALARMES, STATUS AND REMOTE CONTROLS > OKCLICA LOGIC > AG-1 E1 (IN) PLACA DE AGREGADO PRINCIPALCLICA REMOTE_CONTROLCURRENT DISPLAYENABLE INT LOOP (PARA DENTRO DO EQUIPAMENTO) LOOP REMOTOENABLE LINE LOOP (PARA FORA DO EQUIPAMENTO) – INSTRUMENTO

FORÇAR LASER

ABRE O NE (duplo click)CLICA FILE > RECIVE > SAVE > TABLE > OPTICAL SAFETY CONFIGURATIONSELECIONA A OPÇÃO DESEJADA:ALS DISABLE SET TX ON (LASER FORÇADO)ALS DISABLE SET TX OFF (LASER DESLIGADO)ALS DISABLE (CONDIÇÃO NORMAL DE LASER)FILE SEND > OK (CONFERIR A ESTAÇÃO)OBS: PARA DESFAZER REPETE O PROCESSO.

Page 6: nectas1641-1651-100224044512-phpapp02

FORÇAR COMUTAÇÃO

ABRE O NE (duplo click)CLICA FILE > RECIVE > SAVE >ALARMS, STATUS AND REMOTE CONTROLS >> CLICA LOGIC > CLICA NA PLACA CORRESPONDENTE ( EX AGGR MAIN)> REMOTE CONTROL > CURRENT DISPLAY >> MANUAL ACTIVE STM1 AGGR

OBS: PARA RETIRAR A COMUTAÇÃO FORÇADA> SELECIONA A PLACA > REMOTE CONTROL > CURRENT DISPLAY >> CLEAR FORCE ACTIVE STM1 AGG

* COMUTAÇÃO MANUAL: VERIFICA O OUTRO RECURSO ANTES DE COMUTAR* COMUTAÇÃO FORÇADA NÃO VERIFICA O OUTRO RECURSO ANTES DE COMUTAR.

SINCRONISMO

CRU MAIN

ABRE O NE (duplo click)FILE > RECIVE > SAVE >EQUIPMENT CONFIGURATION > OKFILE > RECIVE … AGUARDANOMEIA A ESTAÇÃO > OKTABLE > SYNCRHRONIZATION: ADM TYPE & TRIBUTARY CONFIGURATION > OKMARCA SINGLE ADMSE QUIZER 2M SELECIONA TRIB 1,2,OU 3 E A PORTA = 1° PORTACLICA EM OK

TABLE > SYNCRHRONIZATION PRIORITY LIST CONFIGURATION > OK

Fazer sair por T4 o sinal que tiver entrando na entrada de sincronismo externo T3.Normalmente T4=T0.Referência 1- 2 MHz = GPS (melhor relógio, qualidade G811)Priority de 1 a 6 (1 mais prioritário)Squelch , bloqueia o sinal de relógio se não for melhor ou igual a referência indicada.

OBS: O sistema procura trabalhar com a melhor qualidade, depois avalia a prioridade.Sequencia de qualidade: G811, G812t, G812l, G813.

SSM ALGORITHM ENABLE = MARCAR(É QUEM DEFINE PARA OLHAR PRIMEIRO A QUALIDADE) > CLICA EM OK

TABLE > SYNCRHRONIZATION: SSM VALUE CONFIGURATION

Page 7: nectas1641-1651-100224044512-phpapp02

INFORMA A QUALIDADE: EXTRATED PARA RX ( E1 OU W1) INSERTED PARA TX (E1 OU W1)CLICA EM OK

SOFTWARE MISMASH

CRU MAIN ALARMANDO (PODE SE COMUTAR A SMEC)

VERSÃO DE UNIDADESABRE O NE (duplo click)CLICA FILE > RECIVE > SAVE >ALARMS, STATUS AND REMOTE CONTROLS >SW VERSION > CLICA NA PLACA

PARA VER PACOTE DE SOFTWARE

ABRE O NE> SOFTWARE DOWNLOAD > (VERIFICAR VERSÕES, PACOTE SMEC, DOWNLOADS)> NE IDENTIFICATION > (MOSTRA 2 PACOTES DE SOFTWARES DENTRO DA SMEC EX 1641 V2.7.37)> DESCRIPTOR FILE > (VERIFICA AS VERSÕES DAS UNIDADES EX CRU 3.5.11)

PARA COMUTAR BANCO DE DADOS

SOFTWARE MANAGMENT > ACTIVE > OK (IRÁ COMUTAR O BANCO DE DADOS)OBS: SE O BOTÃO ACTIVATE NÃO ESTIVER HABILITADO, DEVE SE FSZER O DOWNLOAD NOVAMENTE.

DOWNLOADSW DOWNLOAD MENUSW DOWNLOADING (CLICA EM NE TYPE E APAGA 27)SELECIONA O PACOTE (1641 V2.7.37)CLICA CODE PRESENTE.OBS: FORCED DOWNLOAD SÓ É NECESSÁRIO SE NÃO FUNCIONAR. O CODE PRESENTE SIGNIFICA QUE O SOFTWARE IRÁ AUTERAR SOMENTE OS DADOS QUE FOREM DIFERENTES.

CONFIGURAR PROTEÇÃO

EQUIPAMENT CONFIGURATIONTABLE > EPS-ARSMARCA A PLACA E SELECIONA EPS > CLICA OK > FILE > SEND

Page 8: nectas1641-1651-100224044512-phpapp02
Page 9: nectas1641-1651-100224044512-phpapp02

PRACTICE NECTAS 1641-1651

ACCESS NECTAS

USER - ADMIN PASSWORD - ADMIN

BELL> DISABLE

BACKUP

1641 - SM SAVE: EQUIPMENT CONFIGURATION CONNECTION CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES

1651 - SM SAVE: EQUIPMENT CONFIGURATION CONFIGURATION CONNECTION WITH FULL MATRIX CONFIGURATION CONNECTION WITH MATRIX VC4 DROP SHELF CONFIGURATION CONNECTION LOCAL CONFIGURATION ROUTING TABLES

(IF ANY DOUBT SAVE ALL)

NOTE: WHERE HAVE NOT DROP SHELF NEEDS SAVE (1641 SMD), IN 1651 WILL BE A FULL MATRIX OR VC4. DROP SHELF IS A SUB FRAME OF 1641 TO 1651 The 1651 ASSOCIATE IS EQUIPPED TO 1 STM1, WITH DROP SHELF this capability is COM 3 STM1, GETTING UP TO 4 STM1.

BACKUP RUNNING

OPEN NETWORK ELEMENT (DOUBLE CLICK) EQUIPMENT CONFIGURATION> FILE> RECEIVE ENTERING DATA STATION> OK CONNECTION CONFIGURATION FILE> RECEIVE ENTERING DATA STATION> OK LOCAL CONFIGURATION FILE> RECEIVE ENTERING DATA STATION> OK ROUTING TABLES FILE> RECEIVE

Page 10: nectas1641-1651-100224044512-phpapp02

ENTERING DATA STATION> OK

TO SAVE IN ANOTHER FOLDER

GO TO THE FOLDER C: ALCATEL / 1641 OR 1651 SM 27 SM 25 (COPY TO PUT THE SEASON WITHOUT AUTERAR FILE)

CHANGE SMEC

1 2 DIP SWITCH ON OFF NORMAL POSITIONOFF ON CLEANING POSITION ON DATABASEOFF OFF RESTORE LOCAL CONFIGURATION (NE, THE ADDRESS,

LAPD, ETHERNET).ON ON RESTORE DATABASEON OFF NORMAL POSITION

STEPS:

STEP 1 - REMOVE SMEC DIP DIP 1 OFF 2 ON - INSERT PLATE LOOKS AND LED LIGHTING ABN. (THE BANK WAS CLEAN). STEP 2 - REMOVE SMEC I DIP DIP 2 OFF ON -. INSERT PLATE, LOOKS ABN LED LIGHTING (WAS RECOVERED LOCAL CONFIGURATION). STEP 3 REMOVE SMEC I DIP DIP 2 ON ON - INSERT PLATE, LOOKS ABN LED LIGHTING (SEND BACKUP TABLES TO NE).. STEP 4 - REMOVE SMEC DIP DIP 2 OFF ON I - INSERT PLATE, LOOKS ABN LED LIGHTING.

TO RESTORE

SEND FILE (FILE SELECT STATION AND CLICK OK)

SEQUENCE OF TABLES: CONNECTION CONFIGURATION EQUIPMENT CONFIGURATION LOCAL CONFIGURATION ROUTING TABLES OTHER TABLES

INSERT IN MANAGEMENT

Page 11: nectas1641-1651-100224044512-phpapp02

LAPD ETHERNET SETUP (Only for cne's)

LAPD 1 OPEN NETWORK ELEMENT (DOUBLE CLICK) CLICK ON LAPD CONFIGURATION> AGRR STMI E1 (USER)                                                                   > AGRR STM1W1 (NETWORK) LOCAL CONFIGURATION> YES                                                   > NETWORK TABLES> MS LAPD CONFIGURATION E1> W1 2 - ETH> YES                 > FALSE (L2 ONLY) 3 - THE ADDRESS INSERT NSAP MANAGEMENT NO NO 4 - NE ADDRESS (LOCAL CONFIGURATION) INSERT NSAP E 7.1 (ADDRESS OF NE) SYSTEM ID (EX 002 060 222 222) 8 = 7.1 FILE> SAVE> FILE> SEND. NOTE-IF ANY CHANGE NSAP, PERFORMING SYSTEM REBOOT. YOU MUST CONNECT AGAIN.

REMOTE ACCESS

1 - DECLARE IN MY ELEMENT NETWORK, YOU WANT TO SEE THE NSAP'S REMOTELY.

LOCATION / CONFIG> R-ECT YES (BRAND) NSAP 7.1 DIGITAL AND ADDRESS OF REMOTE NE'S. CLICK ON NEXT TO CREATE ANOTHER NE. FILE> SAVE> FILE> SEND.

CLOSE THE NECTAS

2 - START MENU

> PROGRAMS> ALCATEL> NETWORK SETUP > NETWORK CONFIGURATION > NETWORK> CREATE> DEFAUT                                             > NETWORK NAME (GENERAL)                                             > CREATE

Page 12: nectas1641-1651-100224044512-phpapp02

3 - OPEN PAINT BRUSH TO CREATE A FUND TO BE ENTERED IN THE NET (GENERAL).

MAKE A "COPY" IN PAINT BRUSH AND A "MAP> PASTE" IN GENERAL MAP. 4 - CREATE A GENERIC ANY NE EQUIPMENT> CREATE> ME (0)> SECONDARY ADDRESS (5)> CREATE

LEFT BUTTON> LOCATE EQUIPMENT> FIND

5 - EDIT WIN INI The IR C: / WINT / WIN.INI AND EDITING WITH DATA: [PEX] COMPEX = COM1: PEXLOAD = 12TimRetrasmiis = 20sec 12TimPolling = 4sec 12TimResponse = 5sec 12Retry = 1 NETCFG_RECT = YES NETCFG_NETWORK = C: / NETWORK / NETWORK / TXTPATH = C: NETWORK / NETWORK / txtfile / NETWORK_RF = NETWORK NetPath = C: / NETWORK / NETWORK / NETFILE / WMFPATH = C: / NETWORK / NETWORK / WMFILE / NETWORK = NET NOTE-IF THE NAME IS GENERAL MAP, REPLACE THE WORD NETWORK IN GENERAL.

6 - OPENING NECTAS

VIW> NETWORK (appears all elements created) OBS-2-5 is the configuration of Laptop

VIW> SUB NETWORK / Equipaments (double click) ALARMS AND STATUS> OK

CROSS CONNECTION

CREATING CIRCUIT 2 MB OPENS THE NE (double click) CONNECTION CONFIGURATION> OK FILE> RECEIVE> SELECT STATION> OK (Save) TABLE> struture PAYLOAD AND SIGNAL LABEL> OK TABLE> TU-12'S ALLOCATION FOR 21X2M / SCDMA TRIBUTARY> OK MANS TAX MANS TU12 (CREATE CORRESPONDENCE WITH REMOTE SIDE)

Page 13: nectas1641-1651-100224044512-phpapp02

The TEAM MODE (D / I BIDI UNP AND OR W (E W OR UNDER THE PROJECT, ONE SIDE AND THE OTHER W)).

FILE> SEND> SAVE> SEND

OBS = IN SIDE REMOTE SHOULD DO THE SAME PROCESS 1641, 1651, 1664 ONLY TWO HOUSEHOLDS.

DO LOOP 2MB

OPENS THE NE (double click) CLICK ALARM, STATUS AND REMOTE CONTROLS> OK CLICK LOGIC> T2M 1 (MAIN BOARD OF TAX) CLICK ON TAX CLICK REMOTE_CONTROL CURRENT DISPLAY INT ENABLE LOOP 2M (INTO THE EQUIPMENT) REMOTE LOOP ENABLE LINE LOOP 2M (OUT OF EQUIPMENT) - INSTRUMENT

DO LOOP OF HOUSEHOLD

OPENS THE NE (double click) CLICK ALARM, STATUS AND REMOTE CONTROLS> OK CLICK LOGIC> AG-1 E1 (IN) BOARD OF HOUSEHOLD HOME CLICK REMOTE_CONTROL CURRENT DISPLAY INT ENABLE LOOP (INTO THE EQUIPMENT) REMOTE LOOP LINE LOOP ENABLE (OUT OF EQUIPMENT) - INSTRUMENT

FORCE LASER

OPENS THE NE (double click) CLICK FILE> RECEIVE> SAVE> TABLE> OPTICAL CONFIGURATION SAFETY Select a desired option: ALS TX DISABLE SET ON (FORCED LASER) ALS TX DISABLE SET OFF (OFF LASER) DISABLE ALS (NORMAL CONDITION OF LASER) SEND FILE> OK (ENSURING THE SEASON) NOTE: FOR SCRAP REPEAT THE PROCESS.

Page 14: nectas1641-1651-100224044512-phpapp02

FORCE SWITCH

OPENS THE NE (double click) CLICK FILE> RECEIVE> SAVE> ALARMS, STATUS AND REMOTE CONTROLS> > CLICK LOGIC> CLICK ON BOARD CORRESPONDENT (EX AGGR MAIN) > REMOTE CONTROL> DISPLAY CURRENT> > MANUAL ACTIVE STM1 AGGR

NOTE: FORCED TO REMOVE THE SWITCH > SELECT BOARD> REMOTE CONTROL> DISPLAY CURRENT> > CLEAR ACTIVE FORCE STM1 AGG

* MANUAL SWITCH: VERIFY OTHER REMEDY BEFORE SWITCHING * SWITCHING FORCED NOT VERIFY THE OTHER REMEDIES BEFORE SWITCHING.

TIMING

RAW MAIN

OPENS THE NE (double click) FILE> RECEIVE> SAVE> EQUIPMENT CONFIGURATION> OK FILE> RECEIVE LOOKS ... STATION NAMES> OK TABLE> SYNCRHRONIZATION: ADM TRIBUTARY TYPE & CONFIGURATION> OK SINGLE BRAND ADM If I want 2M SELECTS TRIB 1.2, AND THE DOOR OR 3 = 1 DOOR CLICK ON OK

TABLE> SYNCRHRONIZATION PRIORITY LIST CONFIGURATION> OK

Making out on the T4 signal you entering the external sync input T3. Normally T4 = T0. Reference 1 = 2 MHz (GPS clock best quality G811) Priority 1-6 (highest priority first) Squelch blocks the clock signal if not better than or equal to reference indicated.

NOTE: The system seeks to work with the best quality, then evaluates the priority. Sequence quality: G811, G812t, G812l, G813.

ALGORITHM SSM MARK ENABLE =

Page 15: nectas1641-1651-100224044512-phpapp02

(It DEFINE WHO LOOK FOR FIRST QUALITY)> CLICK ON OK

TABLE> SYNCRHRONIZATION: SSM VALUE CONFIGURATION

INFORMATION QUALITY: EXTRATED FOR RX (OR E1 W1)                                                    INSERTED TO TX (OR E1 W1) CLICK ON OK

SOFTWARE mismash

RAW MAIN alarming (CAN SWITCH The SMEC)

VERSION OF UNITS OPENS THE NE (double click) CLICK FILE> RECEIVE> SAVE> ALARMS, STATUS AND REMOTE CONTROLS> SW VERSION> CLICK ON BOARD

TO SEE SOFTWARE PACKAGE

OPENS THE NE > DOWNLOAD SOFTWARE> (CHECK VERSIONS, PACKAGE SMEC, DOWNLOADS) > NE IDENTIFICATION> (2 SHOW PACKAGES SOFTWARE WITHIN THE EX 1641 V2.7.37 SMEC) > DESCRIPTOR FILE> (VERIFY THE VERSIONS OF UNITS EX RAW 3.5.11)

SWITCH TO DATABASE

SOFTWARE MANAGMENT> ACTIVE> OK (WILL SWITCH DATABASE) NOTE: IF YOU DO NOT ACTIVATE BUTTON ENABLED, SHOULD FSZER DOWNLOAD AGAIN.

DOWNLOAD SW DOWNLOAD MENU DOWNLOADING SW (NE TYPE AND CLICK ON DELETE 27) SELECT PACKAGE (1641 V2.7.37) CLICK THIS CODE. NOTE: FORCED DOWNLOAD IS ONLY NECESSARY IF IT DOES NOT WORK. The CODE THIS MEANS THAT THE SOFTWARE WILL ONLY AUTERAR DATA THAT ARE DIFFERENT.

SET PROTECTION

EQUIPMENT CONFIGURATION

Page 16: nectas1641-1651-100224044512-phpapp02

TABLE> EPS-ARS MARK AND BOARD SELECTS EPS> CLICK OK> FILE> SEND