MTD PL049-1

22
©2010 NEC Corporation MTD-PL-049 220323 71-76/81-86 GHz SDH/SONET, GbE DIGITAL RADIO SYSTEM NEC Corporation

Transcript of MTD PL049-1

Page 1: MTD PL049-1

©2010 NEC Corporation MTD-PL-049 220323

71-76/81-86 GHz SDH/SONET, GbE DIGITAL RADIO SYSTEM

NEC Corporation

Page 2: MTD PL049-1

Note: This technical description shows all available functions. The specific functions are made available with eligible combination of hardwares and softwares. Please refer to the valid price list to be ordered to activate the specific functionality.

“Windows” and “Windows Vista” are registered trademarks of Microsoft Corporation. “UNIX” is a registered trademark of The Open Group.

This document describes the current version of NEC standard equipment. If there is any conflict between this document and the System Description and/or the Compliance statement, the latter will supersede this document.

The specifications or configuration contained in this document are subject to change without notice due to NEC's continuing design improvement.

Page 3: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- i -

TABLE OF CONTENTS 1. INTRODUCTION............................................................................................... 1

2. FEATURES....................................................................................................... 3 2.1. Performance.............................................................................................................. 3 2.2. Carrier Grade ............................................................................................................ 3 2.3. Proven Reliability....................................................................................................... 3 2.4. Security ..................................................................................................................... 3 2.5. System Flexibility....................................................................................................... 3 2.6. Maintenance Facilities............................................................................................... 3 2.7. ARM (Adaptive Rate Modulation) .............................................................................. 4 2.8. PASOLINK Network Management System (PNMSj)................................................. 5 2.9. Web Based Management (LCT Web) ....................................................................... 5 2.10. ODU Mounting Configuration .................................................................................... 5

3. BLOCK DIAGRAM AND DESCRIPTION ......................................................... 6

4. NETWORK MANAGEMENT SYSTEM............................................................. 9 4.1. e-PASOLINK Management FEATURES ................................................................... 9 4.2. PASOLINK Network Management System (PNMSj)............................................... 10 4.3. Features .................................................................................................................. 11

5. PERFORMANCE ............................................................................................ 13 5.1. General.................................................................................................................... 13 5.2. Baseband Module ................................................................................................... 14 5.3. System Performance............................................................................................... 15 5.4. Antenna ................................................................................................................... 16

Page 4: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- ii -

This page is intentionally blank.

Page 5: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 1 -

1. INTRODUCTION To provide reliable digital access links and fully exploit the potential of end-to-end advanced networks, NEC has developed the e-PASOLINK, a narrow band point-to-point microwave relay system operating at radio frequency (RF) band of 80 GHz. This system meets an increasing demand for digital transmission services and will satisfy the needs for common carrier access links, private links, urban area networks, rural area networks, temporary networks or emergency links for data and transmission and feature sufficient capacity to simultaneously support legacy TDM and rapidly-growing IP traffic. The e-PASOLINK offers very high performance with large system flexibility, easy to install, field proven reliability and cost effective but also robust and scalable to accommodate future application and capacity needs. The e-PASOLINK system provides interface module types of SDH/SONET and LAN and supports transmission rates of up to 1200 Mbps. The system is a single all outdoor unit that provides simultaneous connection of native SDH/SONET and native Ethernet.

Figure 1. ODU (all out door) (80 GHz)

Capacity Menu

Transmission Capacity /Throughput (Mbps)

120 240 600 1200

Modulation Scheme Channel Separation (MHz)

BPSK 250

QPSK - 250 - -

BPSK - 1000

QPSK - - - 1000

-: Not available

Page 6: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 2 -

Capacity Menu for ARM

Transmission Capacity/Throughput (Mbps)

CS

Modulation Mode 1

250 MHz Mode 2

250 MHz Mode 3

1000 MHz Mode 4

1000 MHz

BPSK 120 - - -

QPSK - 240 - -

BPSK - - 600 -

QPSK - - - 1200

Page 7: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 3 -

2. FEATURES

2.1. Performance • Multi-protocol support in native mode: Up to 4 SDH/SONET +5 Ethernet Interfaces

• Up to 1000 Mbps throughput delivering the equivalent of full gigabit Ethernet plus 200 Mbps

• Efficient spectrum utilization using BPSK/QPSK modulation

• Configurable RF channels for ease of deployment

2.2. Carrier Grade • Carrier Ethernet services enabled through built-in gigabit Ethernet layer 2 switch

• Carrier grade network management

• Effective network planning via RF channel tuning across the entire 70/80 GHz band

• Rapid and flexible deployment

• Utilizes Automatic Transmit Power Control (ATPC) for high availability

2.3. Proven Reliability • Up to 99.999% Carrier-grade reliability

2.4. Security • Highly secured narrow beam-width antenna

• AES Encryption option provides the ultimate in data protection at full-line-rate gigabit speeds

• User settable LINK ID codes: up to 256 internal ID codes

2.5. System Flexibility • Changeable data transmission rate (STM-1/OC-3 155.52 Mbps, STM-4/OC-12 622.08

Mbps, 10/100/1000 Base-T, 1000 Base-SX/LX) at the same ODU

• Common ODU for SDH/LAN,

• Wide Input Line Voltage range from –37.5 to –70 VDC

2.6. Maintenance Facilities • Local and remote supervision function on ODU via Web-based (HTML) embedded

management agent or HTTPS secure management option

• Remote monitoring of ODU operating condition through Web-based management agent

• Full back access at ODU for all cabling and user interface

• Loop back facility SONET/SDH loopback Radio loop back

Page 8: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 4 -

2.7. ARM (Adaptive Rate Modulation)

2.7.1. Introduction e-PASOLINK’s ARM (Adaptive Rate Modulation) feature provides gradual adaptive data rate and modulation changes to the transmission that alters the modulation type and/or changes the signal bandwidth, allowing the link to maintain high availability connections during rain fades. As anomalies in the path reduce signal levels, e-PASOLINK shifts the modulation from QPSK to BPSK, and capacity decreases in incremental steps. The internal engine provides the necessary prioritization of the Ethernet and SONET/SDH traffic to maintain quality of service at the new data rate. Once the anomaly subsides, E-Band PASOLINK automatically restores transmission capacity.

2.7.2. ARM range Table 2 shows the ARM range for Channel spacing and modulation scheme.

Table 2 ARM range Transmission Capacity

/Throughput (Mbps) 120 240 600 1200

Modulation Scheme Channel Separation (MHz)

BPSK 250 - - -

QPSK 250

BPSK - 1000

QPSK - - - 1000

Figure 2. ARM capacity changing image

Page 9: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 5 -

2.8. PASOLINK Network Management System (PNMSj) • User-friendly operation

• Support in-band management

• Free from OS limitations, PNMSj runs either Windows® XP or Windows Vista® or UNIX®

• ITU-T G.826/G.828 Performance monitor (Table/Graph presentation)

• SNMP Interface

• NE Summary thru MIB Loading

2.9. Web Based Management (LCT Web) • User-friendly operation as maintenance terminal

• Support in-band and out-band management

• Uses Windows® XP or Windows Vista®, which enable use of Mobile PC

2.10. ODU Mounting Configuration • Direct Mounting on Antenna

Figure 3. 80 GHz Direct Mounting PASOLINK ODU

Page 10: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 6 -

3. BLOCK DIAGRAM AND DESCRIPTION

Figure 4. e-PASOLINK Modules

Overview The e-PASOLINK ODU electronics are comprised of three modules:

1. Baseband Module (BBM)

2. IFPS Module (IFPS)

3. Front-End Head (FEH)

Figure 5. e-PASOLINK BLOCK DIAGRAM

FEH

Ethernet L2

Switch

MMW

FPG

1G Ether 10/100/1000

BASE-T

SFP OC-3/12 STM-1/4

1 Gbps

200 Mbps

SONET/ SDH INF Variable

Rate

IFPS

RX IF

Power Supply

TX IF

BBM

1G Ether SFP (SX/LX)

Page 11: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 7 -

Baseband Module The Baseband Module (BBM) provides multiple network interfaces to connect the outside world to the radio. Up to four SONET/SDH interfaces are supported through SFP modules interface. Up to additional Ethernet interfaces are supported through a second SFP modules interface and one 10/100/1000 copper Ethernet interface with standard RJ-45 connector. All of the Ethernet interfaces are connected to an Ethernet switch. The Ethernet switch and the SONET/SDH interfaces are connected to an FPGA with multiple high-speed SERDES interfaces. The FPGA combines the multiple data streams, formats the data, adds forward error correction coding and optional encryption. The resulting high-speed data streams are output to the IFPS. The FPGA also processes the high-speed received data from the IFPS.

IFPS Module The IFPS Module has three main functions: provides the transmitter path from the BBM to the FEH, provides the receiver path from the FEH to the BBM, and regulates the external 48 VDC power down to the main 5.5 V supply rail for the radio.

FEH Module The FEH Module has four main functions: up convert the transmit IF signal to millimeter-wave frequencies, down convert the receiver millimeter-wave to the receive IF frequency, combine the millimeter-wave TX and RX signals into one antenna port, and provide a millimeter-wave loopback path for testing and debug.

Ethernet L2 Switch This switch has four (4) SFP’s and one (1) RJ45 port available for external network devices connection. It contains interfaces connected to management control unit and to Primary & Secondary radio interfaces. Any combination of ports can be used to carry traffic across the link.

SONET/SDH INF The SONET/SDH traffic is handled separately within the radio & does not pass through internal switch. Up to four SONET/SDH Interfaces are supported through an SFP modules interface. .

Power Supply The nominal power supply voltage is –48 VDC. However, the range of the unit is –37.5 to –75 VDC.

Page 12: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 8 -

30cm Type 60cm Type

Figure 6. ALL OUTDOOR e-PASOLINK (71~86 GHz)

Page 13: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 9 -

4. NETWORK MANAGEMENT SYSTEM

4.1. e-PASOLINK Management FEATURES

4.1.1. Web based Interfaces (LCT Web) e-PASOLINK holds a built-in web based tool for all configuration, control, operations and monitoring. (HTTP, secure HTTPS)

4.1.2. SNMP Agent e-PASOLINK has a built-in SNMP (V1 and V2) management agent for remote monitoring via any SNMP compatible element manager.

4.1.3. IP Addressing e-PASOLINK carries IPV4 addressing via user configured static IP addresses or configuration via DHCP server

4.1.4. Security e-PASOLINK supports user authentication via passwords as well as RADIUS server authentication.

4.1.5. Link ID Codes e-PASOLINK develops user-settable (up to 256 internal codes) Link ID Codes that providing an additional layer of security such that an unwanted or rouge receiver cannot lock up on and access data being transmitted from the remote station.

4.1.6. Software Upgrades e-PASOLINK can be upgraded via a software upgrade key at a later date to allow for the following feature additions:

• Capacity Upgrade from 240 Mbps to 600 Mbps

• Capacity Upgrade from 600 Mbps to 1200 Mbps

• Capacity Upgrade from 240 Mbps to 1200 Mbps

• Adaptive Rate and Modulation (requires data rate of 600 Mbps or higher)

• AES 256-bit Encryption (available with Ethernet only or 4TDM models)

• Firmware Upgrades

4.1.7. AES Encryption e-PASOLINK can be upgraded to provide 256-bit AES Encryption on the transmission path via a software upgrade key.

Page 14: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 10 -

4.1.8. Syslog e-PASOLINK has a Syslog event log browser that captures 256 events in a circular buffer and can be read via the HTTP/HTTPS interface.

4.1.9. Alarm Monitoring e-PASOLINK provides for monitoring of local and remote self-generated alarms via the HTTP/HTTPS interface. There is no option to provide for the monitoring of external site alarms.

4.1.10. Testability e-PASOLINK contains the ability to provide test functions supporting: Local Transmit Mute and Loopback at the RF and Access Levels

4.2. PASOLINK Network Management System (PNMSj)

4.2.1. General The PASOLINK Network Management System Java version (PNMSj) is designed to bring comprehensive, easy-to-use and cost-effective management to the integrated microwave network environment. A user-friendly graphical interface together with a set of integrated tools enables the network operators to remotely monitor and control the status and configuration of the entire PASOLINK family Radio networks. This system also provides monitoring of the real-time microwave link performance, easy viewing of various radio parameters, and advanced alarm management.

• Automatic Alarms Monitoring

• Display NE by the icon classified by color for each summary alarm.

• Starting up of LCT of e-PASOLINK

Page 15: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 11 -

4.3. Features

4.3.1. Any platform Free from OS limitations, PNMSj runs on either Windows® XP or Windows Vista® or UNIX®. PNMSj is based on SNMP Manager/Agent Technology.

4.3.2. User-friendly Operation PNMSj displays a network overview with click and pull down menus to obtain detailed status information and to change the configuration of the network elements. The multiple level window structure provides easy guidance to pinpoint the PASOLINK station of concern and subsequently the component of concern. Starting with a map showing the sub-groups, followed by maps showing the various sub-group configurations, an operator can find an overview window for any PASOLINK station quickly.

4.3.3. Link Oriented Management and Control For operational convenience, the PNMSj/PNMTj automatically displays the status of the opposite PASOLINK station together with key link parameters.

4.3.4. Remote Access and Control PNMSj Clients are able to monitor and control NEs using most Web browsers (IE, etc). Remote NEs can be accessible using LAN interface.

4.3.5. Event Logging This PNMSj is useful for monitoring all events occurring within the network. It is designed to ease the maintenance and troubleshooting work on the PNMSj. The events are listed in an easy–to-view formats giving the user information about the date and time it occurred, the network element where it occurred, its item and status. The User column has offered for event log that the user controlled, and showing login user name is also supported. The event log window is incorporated in the PNMSj main window. The logs are displayed at the bottom of the PNMSj screen.

4.3.6. Alarm Management The Active Alarm function supports monitoring of active alarms on all connected network elements. Alarms that have been cleared in the NE will remove on the Active Alarm window and logged in the Alarm History window. The Alarm Information View is used to view the summary of current active alarms. This screen shows the list of active alarm information of NEs belonging to the same group. The list also shows what alarm severities are currently active in the NE and whether it has been acknowledged or not. The total count of current active alarms (Not Ack and Total) in each category is shown at the top of the main window.

Page 16: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 12 -

4.3.7. ITU-T G.826 Performance Monitor The PNMSj is able to retrieve the performance data of all listed PASOLINK stations and their associated microwave link in accordance with ITU-T specification G.826.

- Scheduled or on-demand upload

- Report or chart presentation

- Threshold setting and alerts

4.3.8. Security Users are registered by means of a login name and password. To protect the network and network management system from unauthorized access or unauthorized modifications, the privileges are assigned to the groups rather than to the individual user. A user will have the privilege provided to the group where it belongs. Moreover, the control of network elements can be customized and provided only to specific groups. This allows the administrator a high-flexibility of assigning not only the PNMSj functions but also the control and management of individual NE. Lastly, users and groups created in PNMSj are internal to PNMSj only and do not correspond to Windows users and groups.

4.3.9. SNMP Interface PNMSj provides an SNMP interface to make the PASOLINK equipment an integral part of a higher level of network management system.

Page 17: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 13 -

5. PERFORMANCE

5.1. General ITEM SPECIFICATION

FREQUENCY RANGE 71.125 ~ 85.875 GHz Frequency Plan CEPT ECC 05/07, CFR47 Part 101 (FCC) Band Limits 71~76 GHz / 81~86 GHz Channel Spacing 250 MHz / 1000 MHz T/R Spacing 10 GHz

CAPACITY TDM Capacity 155 Mbps / 622 Mbps LAN Capacity min. 120 Mbps / max. 1200 Mbps Adaptive Rate Capacity 120 Mbps / 240 Mbps / 600 Mbps / 1200 Mbps

DATA INTERFACES TDM up to 4 SFP ports (STM-1/OC-3, STM-4/OC-12) Ethernet up to 4 SFP ports (1000 Base-SX/LX)

+ one RJ-45 port (10/100/1000 Base-T) ENVIRONMENTAL

Temperature, Operational –33°C to +55°C Humidity, Operational 100% all-weather Transportation / Storage EN300019-2-3, Class 1.2 for weather protected locations

EMC EN300489-1,-4 SAFETY EN60950, UL60950 POWER REQUIREMENT

Input Voltage –48 VDC (–37.5 V to –70 V) Power Consumption 60 watts

MECHANICAL Dimensions (W x H x D) 11.5” x 11.5” x 5” (29.2 cm x 29.2 cm x 12.7 cm) Weight 14 lbs (6.4 kg)

Page 18: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 14 -

5.2. Baseband Module

5.2.1. Digital Signal Interface Type Interface Bitrate (Mbps) Cable Module Connector TDM STM-1/OC-3 155 Mbps S.M Fiber SFP LC STM-4/OC-12 622 Mbps S.M Fiber SFP LC Ethernet 1000 Base-T 10/100/1000 Copper --- RJ-45 1000 Base-SX 1000 M.M Fiber SFP LC 1000 Base-LX 1000 S.M Fiber SFP LC

5 GbE ports (1x RJ45 copper and 4x SFPs for single mode, multimode or copper interfaces) and up to 4x TDM ports supporting native SDH/SONET interfaces (STM-1/OC3 or STM-4/OC12) are available. Any combination of TDM + IP up to a maximum over the air data rate of 1200 Mbps (primary and secondary) is supported.

5.2.2. Ethernet Traffic and Services • Frame Type : supports 802.3 and 802.1Q

• Traffic Management : VLAN

• Flow Control : per 802.3x

• Auto Negotiation : supports 10/100/1000 interfaces

• Frame Size : supports Jumbo Frame up to 10,000 bytes

• Latency : dependent on frame size. As low as 65 uSec @ 1.2 Gbps.

• Counters : detailed Ethernet port statistics are available via HTTP

• Per-Port Ethernet : supports per-port rate limiting and Ethernet Counters

• Layer 2 Ethernet Switch : supports L2 switching functionality

• MAC Learning : supports MAC Learning

• MAC Switching : supports MAC switching

• MAC Ageing : supports MAC ageing

• Rapid Link Shutdown : supports RLS via LSP

5.2.3. Management Interfaces In-Band or Out-of-Band management separated from VLAN

• Interface : RJ-45 copper

SFP, multi mode or single mode LC connector

Page 19: MTD PL049-1

MTD-PL-049/220323 e-PASOLINK

- 15 -

5.3. System Performance ITEM SPECIFICATION

Modulation / BANDWIDTH 1200 Mbps QPSK / 1000 MHz bandwidth

600 Mbps BPSK / 1000 MHz bandwidth 240 Mbps QPSK / 250 MHz bandwidth 120 Mbps BPSK / 250 MHz bandwidth

TRANSMITTER Power Output (BPSK/QPSK) +18 dBm TX Power Output Stability +/– 2dB ATPC Range 30 dB Radiated TX Spectrum Mask EN 302217 (2008-11) TX Spurious Emission ERC/REC 74-01E

RECEIVER Maximum Input Level –5 dBm Threshold Level 10

-12 BER 10

-6 BER

1200 Mbps / QPSK –62 dBm –63 dBm 600 Mbps / BPSK –65 dBm –66 dBm 240 Mbps / QPSK –69 dBm –70 dBm 120 Mbps / BPSK –72 dBm –73 dBm

Co-Channel Interference EN 302 217 3 dB degradation 19 dB 1 dB degradation 23 dB

CW Spurious Emissions EN 302 217 (2008-11) RX Spurious Emissions ERC/REC 74-01E Residual BER < 1x10

-12

SYSTEM GAIN 10-12

BER 10-6

BER 1200 Mbps 80 dB 81 dB

600 Mbps 83 dB 84 dB 240 Mbps 87 dB 88 dB 120 Mbps 90 dB 91 dB

Page 20: MTD PL049-1

e-PASOLINK MTD-PL-049/220323

- 16 -

5.4. Antenna

5.4.1. Antenna Menu for Direct Mount and Performance 30 cm (12”) diameter 60 cm (24”) diameter Gain (Low band) 43 dBi 50 dBi Gain (Middle band) 43.8 dBi 51 dBi Gain (High band) 44.6 dBi 52 dBi 3 dB Beam width 0.9 degrees 0.4 degrees Cross Pole Discrimination 30 dB 30 dB Front-to-Back Ratio 64 dB 60 dB Type Parabolic cassegrain Parabolic cassegrain Weight (no ODU) 14 lbs (6.4 kg) 30.5 lbs (13.8 kg) Weight (with ODU) 28 lbs (12.7 kg) 44.5 lbs (20.2 kg)

Page 21: MTD PL049-1
Page 22: MTD PL049-1

MTD-PL-049/220323 NEC Corporation, Tokyo, Japan