    MSS Hardware Installation Quick Reference Guide

    MSS Hardware Installation QuickReference Guide

    Release M14.0

  • 7/29/2019 MSS Installation.pdf

    2/12

    The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This document is not an officialcustomer document and Nokia Siemens Networks does not take responsibility for any errorsor omissions in this document. This document is intended for the use of Nokia Siemens

    Networks customers only for the purposes of the agreement under which the document issubmitted. No part of this documentation may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networkswelcomes customer comments as part of the process of continuous development andimprovement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacityor performance of the mentioned hardware or software products are given as is and allliability arising in connection with such hardware or software products shall be definedconclusively and finally in a separate agreement between Nokia Siemens Networks and thecustomer.

    IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TOSPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSESSUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS

    INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, that might arise from the use of thisdocument or the information in it.

    THE CONTENTS OF THIS DOCUMENT ARE PROVIDED "AS IS". EXCEPT AS REQUIREDBY APPLICABLE MANDATORY LAW, NO WARRANTIES OF ANY KIND, EITHEREXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIESOF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT, ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY ORCONTENTS OF THIS DOCUMENT. NOKIA SIEMENS NETWORKS RESERVES THE RIGHTTO REVISE THIS DOCUMENT OR WITHDRAW IT AT ANY TIME WITHOUT PRIORNOTICE.

    This document and the product it describes are considered protected by copyrights and otherintellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademarkof Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective

    owners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2009. All rights reserved.

  • 7/29/2019 MSS Installation.pdf

    3/12

    MSS Hardware Installation Quick Reference Guide

    MSS Hardware Installation Quick Reference Guide

    This quick reference guide is an accompanying document to theinstallation manual. The instructions in the installation manual arecomplete and must be followed. Read the installation manual carefullybefore installing MSS hardware.

    WARNING

    For safety reasons, installation personnel must be familiar with andcompetent in the use of the installation tools.

    WARNING

    The cabinets are heavy. Moving, lifting, and lining a cabinet, if thecabinet is already assembled, require at least two persons.

    Note

    Any modifications not expressly authorised by Nokia Siemens Networkscould void the user's authority to operate this system.

    Installation steps

    1. Check the equipment delivery contents and condition. Note thatthe equipment packaging contains information on the parts andtheir installation positions.

    2. Install the cabinets on feet or on floor rails.

    3. Attach the cabinets together.

    4. Connect the grounding.

    5. Connect the power supply to group jumpers.

    6. Install the roof panels and route the cabinet power supply cabling.

    7. Install the plug-in units (if not already equipped).

    8. Connect the internal and external cabling (see Intercabinet CableLists for M14.0 MSS).

    9. Mount the cabinet doors.

    10. Fill in the required forms and clean the site.

  • 7/29/2019 MSS Installation.pdf

    4/12

    Tools needed for installation

    Pocket tape measure 3 m

    Knife

    Cable stripper and coaxial cable stripper (optional)

    Hexagonal ball head driver 5 mm

    Allen key set, ball head 9 pcs 1.5-10 mm

    Screwdriver set

    Side cutters

    Torx TC20 and TX25

    Multimeter 23

    Crimping tool Crimpex DCC 0908 (optional)

    Connection tool LSA plus (optional)

    Drill (optional)

    Grounding wrist belt

    Antistatic bed

    10 mm socket wrench

    Work light (optional)

    In addition, 1.5 m (5 ft) high safety ladders are needed at the site.

  • 7/29/2019 MSS Installation.pdf

    5/12

    MSS Hardware Installation Quick Reference Guide

    Cabinet dimensions

    600 mm

    Max2000 mm

    1950 mm

    900 mm

    Front

    Back

    Cabling hole, bottom view

    300 mm

    170 mm

    260 mm

  • 7/29/2019 MSS Installation.pdf

    6/12

    Install the cabinets on feet (A) or on floor rails (B).

    CABINET

    FLOOR

    ca. 5 mm (0.2")RAIL

    WRENCH GAP50 mm (2")

    RACK FRAME

    INITIALINSTALLATION

    HEIGHT50 mm (2")

    ADJUSTMENTRANGE

    +/- 20 mm(+/- 0.8")

    TURN TO ADJUST

    A

    B

    - Hammer Drill- Vacuum Cleaner- Bolts- Wedge anchors

    1

    2

    3

    HEX BOLT -M10 x 40(4 pcs)

    WASHER -10,5 mm(4 pcs)

    1

    2

    3

    CABINET

  • 7/29/2019 MSS Installation.pdf

    7/12

    MSS Hardware Installation Quick Reference Guide

    Attach the cabinets together

    ADJUST T090 - DEGREE ANGLE

    ADJUST T090 - DEGREE ANGLE

    .

    .

    ALIGN LEVEL WITHPREVIOUS CABINET

    M4 x 8 (14 pcs)

    8 10 mmHEX BOLT(6 pcs)

    REAR SIDEOF CABINET

    REAR SIDEOF CABINET

    M4 x 8 (14 pcs)

    SideCableConduit

    Support

    Optional

    2

    1. Align the cabinets together in level.Attach the cabinets together with bolts.

    2. Install the side cable conduit if used. The optionalcabling cabinet is preinstalled at the factory.

  • 7/29/2019 MSS Installation.pdf

    8/12

    Ground the cabinet

    Grounding

    ALLEN KEY

    TO PREVIOUS CABINET TO NEXT CABINET

    TO PREVIOUS ROW

    TO NEXT ROW

    TO SITEGROUND (ONLYONE PERNETWORKELEMENT)

    REAR SIDE OF CABINET

    1

    2

    3

    1. Connect the grounding cables to thecabinet either from top or from bottom.

    2. Connect the branch grounding cables to the cabinets and the row grounding cable.

  • 7/29/2019 MSS Installation.pdf

    9/12

    MSS Hardware Installation Quick Reference Guide

    Connect the power supply to group jumpers

    WARNING

    Danger of hazardous voltages and electric shock! Before connecting orremoving any power supply cables to or from the power distribution unit,make sure that both site power feeds to the power distribution unit areoff, the circuit breakers on the front panel of the power distribution unitare in the OFF position, and the equipment is properly earthed(grounded).

    See the installation manual for information on power supply with four power supply lines.

  • 7/29/2019 MSS Installation.pdf

    10/12

    Install the plug-in units (optional)

    WARNING

    Plug-in units are very sensitive to rough treatment. Handle plug-in unitswith care during installation.

    WARNING

    Electrostatic discharge (ESD) may damage components in the plug-inunits or other units. Wear an ESD wrist strap or use a correspondingmethod when handling the units, and do not touch the connectorsurfaces.

    1. Register the bar codes of the plug-in units.

    3. Install the plug-in units. See the packing list to check the plug-in units included in the delivery.

    2. Verify the jumper settings according to the jumper settings manual.

  • 7/29/2019 MSS Installation.pdf

    11/12

    MSS Hardware Installation Quick Reference Guide

    Route the internal and external cabling

    REAR SIDE

    5

    4

    3

    2

    1

    14AC

    0

    PDFU-B0

    PDFU-B1

    AIR GUIDE

    FTRB-A 1 FTRB-A 0

    AIR GUIDE

    LA

    NU

    LASWC-A

    CL

    SU

    CLOC-B

    CL

    BU

    CLAC-B

    246LA

    NU

    LASWC-A

    CPBP 0

    CPEA 1

    CPRS-A 2

    CPRS-A 3

    CPLAN-A 4

    CPLAN-A 5

    CPLAN-A 6

    CPBP 7

    CPBP 8

    CPBP 9

    CPBP 10

    CCC

    FTRB-A 3 FTRB-A 2

    0369

    CC4C-BCC4C-BDC4C-BDC4C-B

    0

    0

    MC2C-A

    6

    MC2C-A

    SD

    CHU

    SU

    CHU

    STU1

    VLRU

    SD

    CHU

    SD

    CHU/SU

    CHU

    STU

    0

    VLRU

    0

    MC2C-A

    6

    MC2C-A

    BDCU1

    BDCU0

    SUSUSU

    OMU 1 OMU 0

    SUSUSUSUSU

    CMU

    1

    SU

    CMU

    1

    CMU

    0

    SD0OMU

    CM

    M0

    CM

    M1

    DC3C-B

    8

    14BC 0

    FTRB-A 0 FTRB-A 1

    FTRB-A 2 FTRB-A 3

    PDFU-B0

    PDFU-B1

    AIR GUIDE

    AIR GUIDE

    BDCU

    2

    DC3C-B

    CLBU

    4,5

    CLAC-B

    CLBU

    2,3

    CLAC-B

    LANU

    2

    LASWC-A

    LANU

    3

    LASWC-A

    VLRU

    1-0

    VLRU

    2-0

    CHU

    1-0

    SD

    CHU/*SU

    CHU

    0HD

    MC2C-A

    VLRU

    1-1

    VLRU

    2-1

    CHU

    1-1

    CHU

    1HD

    MC2C-A

    *SU

    *SU

    *SU

    *SU

    MC2C-A

    *SU

    *SU

    *SU

    MC2C-A

    *SU

    *SU

    *SU

    MC2C-A

    *SU

    *SU

    *SU

    MC2C-A

    1B14AC MSC Server

    PDFU-B0

    PDFU-B1

    FTRB-A 0 FTRB-A 1

    FTRB-A 2 FTRB-A 3

    AIR GUIDE

    AIR GUIDE

    LANU

    0

    LASWC-A

    LANU

    1

    LASWC-A

    CLSU

    0,1

    CLOC-B

    CLBU

    0,1

    CLAC-B

    OMU 0+HD

    CC4C-B

    OMU 1+HD

    CC4C-B

    *SU

    *SU

    *SU

    *SU

    *SU

    MC2C-A

    *SU

    *SU

    B

    DCU

    1

    *SU

    B

    DCU

    0

    MC2C-A

    VLRU

    0-0

    STU

    0

    CHU

    0-0

    SD

    CHU/*SU

    CHU

    0HD

    MC2C-A

    VLRU

    0-1

    STU

    1

    CHU

    0-1

    CHU

    1HD

    MC2C-A

    *SU

    0

    1

    2

    3

    4

    5

    6

    8

    9

    10

    7

    CCC

    CPBP

    CPEA

    CPRS-A

    CPRS-A

    CPLAN-A

    CPLAN-A

    CPLAN-A

    CPBP

    CPBP

    CPBP

    CPBP

    1A

    CMM0

    CMM1

    DC3C-B

    DC4C-B

    CMU

    1

    *SU

    DC4C-B

    SD

    OMU

    CMU

    0

    *SU

    *SU

    *SU

    *SU

    *SU

    *SU

    *SU

    *SU

    *SU

    *SU

    Empty

    FRONT SIDE

    1. Connect the internal cables between cabinets according to the cable lists.

    2. Connect the external cables leaving the network element according to thesite cabling plan.

  • 7/29/2019 MSS Installation.pdf

    12/12

    Mount the cabinet doors.

    Rear sideDoor grounding cable

    A

    A

    B

    B

    Front sideDoor grounding cable

    Fill in the required forms and clean the site.

    1. Verify against the check list that you have completed all the

    necessary steps for the installation.2. Clean the site.3. Make sure that the packing material is taken care of and recycled

    according to the local regulations.4. Fill in the Installation work checklist and Certification of Completion.

    Installation workchecklist

    Certificate ofcompletion