6
114 System Manual - Drive System for Decentralized Installation
MOVIMOT® Basic Unit (Inverter)
6 Unit Design
6.1 MOVIMOT® Basic Unit (Inverter)
02589AXX
1. Designation of connection method2. Terminal box3. Connection plug between connection unit and inverter4. Terminal box cover with inverter and heat sink5. Connection unit with terminals6. Electronics terminal strip X27. Connection of brake coil (X3). For motors without brake: Connection of internal brake resistor BW. (standard)8. Power supply connection L1, L2, L3 (X3) (suitable for 2 x 4 mm2)9. Screws for connecting protective ground �10. Cable glands11. Electronics name plate12. Safety hood for inverter electronics13. Setpoint potentiometer f1 (not shown), accessible through a screwed gland on the top of the connection box cover14. Setpoint switch f2 (green)15. Switch t1 for integrator ramp (white)16. DIP switch S1 for setting bus address, motor protection, DC braking, PWM frequency17. Status LED (visible from the top of the connection box cover, see the section "Operation and Service")
1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17
System Manual - Drive System for Decentralized Installation 115
6MOVIMOT® Basic Unit (Inverter)
MOVIMOT® Nameplates, Type Designations
Motor nameplate
(Example)
05113AXX
KA 77 DT 90L4 BMG/MM15/MLU
Additional feature Inverter 1)
1) Only factory-installed options are listed on the nameplate.
MOVITRAC® frequency inverter
Additional feature Motor (brake)
Motor size, number of poles
Motor series
Gear unit size2)
2) Detailed information about geared motor combinations can be found in the catalog "MOVIMOT Geared
Motors."
Gear unit series2)
04145AXX
SEW-EURODRIVE
TypNr.KW
kg 73
50Hz
60Hz
r/min
Bremse
KA77 DT 90L4 BMG MM15 MLU010012345.6.00.001,5 / 50 HZ
V 380-500V 380-500
22/1400V 230Ma 665
IEC 34B30,99
3,503,5054 F
64,75
Kl
:1
Schmierstoff
Bruchsal / Germany3 ~IM
cos
AAIPGleichrichteri
ϕ
Nm 20Nm
Made in Germany 184103 3.14
K77
MLU..MM15
DT 90L4BMG
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
6
116 System Manual - Drive System for Decentralized Installation
MOVIMOT® Basic Unit (Inverter)
Inverter Nameplate
(Example)
50457AXX
MM 15 B – 503 – 00
Design (00 = Standard)
Connection type (3 = 3-phase)
Connection voltage(50 = 380...500 VAC)(23 = 200...240 VAC)
Version B
Motor power (15 = 1.5 kW)
MOVIMOT® series
System Manual - Drive System for Decentralized Installation 117
6Fieldbus Interfaces
6.2 Fieldbus Interfaces
MF.21 Fieldbus
Module
MF.22, MF.32
Fieldbus Module
50353AXX
1 Diagnostics LEDs2 Diagnostics interface (below the screw fitting)
1
2
50352AXX
1 Diagnostics LEDs2 Diagnostics interface (below the screw fitting)3 M12 connection sockets4 Status LED
1
2
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
6
118 System Manual - Drive System for Decentralized Installation
Fieldbus Interfaces
Underside of
Module (all MF..
types)
Unit Design of
MFZ… Module
Carrier
01802CDE
1 Connection to module carrier2 DIP switch (for MFD and MFO: 2 DIP switches)3 Gasket
2
3
1
01805CXX
1 Terminal strip (X20)2 Floating terminal block for 24 V through-wiring
(Caution! Do not use for shielding!)3 M20 cable gland4 M12 cable gland5 Grounding terminal6 Only DeviceNet and CANopen Micro-style connector (X11)
2 EMC cable glands are part of the scope of delivery.
63
5
4
3
4
2
31
System Manual - Drive System for Decentralized Installation 119
6Fieldbus Interfaces
MFI23B, MFI33B
Fieldbus Module
(Rugged-Line
Plug Connector)
50320AXX
1 Diagnostics LEDs2 Diagnostics interface (below the screw fitting)3 M12 connection sockets4 Status LED5 Rugged-line connection "Remote IN" (incoming remote bus and 24 VDC supply)6 Rugged-line connection "Remote OUT" (outgoing remote bus and 24 VDC supply)
������
��
�
���
��
���
���
���
���
��
��
�����
����
�� ��
�
��
���
�
�
�
�
�
������ ��
��� �
������ ���
�����
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
6
120 System Manual - Drive System for Decentralized Installation
Fieldbus Interfaces
Type Designations / Nameplates MF.. Fieldbus Interfaces
Example for Type
Designation
Example for
Nameplates
Bus module:
Module carrier:
MFP 21 D / Z21 D
Version
Module carrier:Z11 = for InterBusZ21 = for PROFIBUSZ31 = for DeviceNet and CanOpen
Version
21 = 4 x I / 2 x O (connection via terminals)22 = 4 x I / 2 x O (connection via plug connectors + terminals)32 = 6 x I (connection via plug connectors + terminals)
23 = 4 x I / 2 x O (fiber optic rugged line, only for InterBus)33 = 6 x I (fiber optic rugged line, only for InterBus)
MFI... = InterBusMFP... = PROFIBUSMFD... = DeviceNetMFO.. = CanOpen
50460AXX
50459AXX
Sach.Nr.8236240 .10 .10Nr. 0151264Profibusmodul MFP 21D
Sach.Nr.8236275 .-- .-- Nr. 0151269Busmodul MFP 21D
System Manual - Drive System for Decentralized Installation 121
6Field Distributors
6.3 Field Distributors
MF.../Z.3. Field
Distributor
05108AXX
1 2 x M16 x 1.5 (2 EMC cable glands are part of scope of delivery)2 2 x M25 x 1.5 3 2 x M20 x 1.54 Connection potential compensation5 Connection hybrid cable, connection to MOVIMOT® (X9)6 Terminals for fieldbus connections (X20)7 Terminals for 24 V connection (X21)8 Terminals for power supply and PE connection (X1)9 Only DeviceNet and CANopen Micro-style connector
9
1
2
3
4
1
22
3
4
8
6 7
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
6
122 System Manual - Drive System for Decentralized Installation
Field Distributors
MF.../Z.6. Field
Distributor
05244AXX
1 Connection hybrid cable, connection to MOVIMOT® (X9)2 Connection potential compensation3 Maintenance switch with line protection (triple lockable, color: black/red)
03546AXX4 Terminals for power supply and PE connection (X1)5 2 x M25 x 1.56 Terminals for bus, sensor, actuator, 24 V connection (X20)7 6 x M20 x 1.5 (2 EMC cable glands are part of scope of delivery)8 Terminal block for 24 V through-wiring (X29), internally connected with 24 V connection on X209 Pluggable terminal "Safety Power" for 24 V MOVIMOT® supply (X40)
1 2 3 4 5 6 7 9 2 8
I ON I ON
0 OF
F
0 OF
F
Ø 5...Ø 8 mm
System Manual - Drive System for Decentralized Installation 123
6Field Distributors
MF.../MM../Z.8.
Field Distributor
05241AXX
1 Terminals for power supply and PE connection (X1)2 Maintenance switch (triple lockable, color: black/red)
03546AXX3 Cable gland 2 x M25 x 1.54 Terminals for bus, sensor, actuator, 24 V connection (X20)5 6 x M20 x 1.5 cable gland (2 EMC cable glands are part of scope of delivery)6 MOVIMOT® frequency inverter7 Connection potential compensation8 Connection hybrid cable, connection to AC motor (X9)9 Terminal block for 24 V through-wiring (X29), internally connected with 24 V connection on X2010 Pluggable terminal "Safety Power" for 24 V MOVIMOT® supply (X40)
3 5 7
8
6
2
1
4
10
9
I ON I ON
0 OF
F
0 OF
F
Ø 5...Ø 8 mm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
6
124 System Manual - Drive System for Decentralized Installation
Field Distributors
Field Distributor Type Designations
Example MF../Z.3.
Type Designation
Example MF.../Z6.
Type Designation
Example MF.../
MM../Z.8. Type
Designation
MFP21D/Z23D
Connection moduleZ13A = For InterBusZ23D = For PROFIBUSZ33A = For DeviceNet and CANopen
Fieldbus interfaceMFI... = InterBusMFP... = PROFIBUSMFD.. = DeviceNetMFO.. = CANopen
MFP21D/Z26D/AF0
Connection technologyAF0 = Metric cable entryAF1 = With micro-style connector for
DeviceNet and CANopenAF2 = M12 plug connector for PROFIBUSAF3 = M12 plug connector for PROFIBUS +
M12 plug connector for 24 VDC supply
Connection moduleZ16A = for InterBusZ26D = for PROFIBUSZ36A = for DeviceNet and CANopen
Fieldbus interfaceMFI... = InterBusMFP... = PROFIBUSMFD.. = DeviceNetMFO.. = CANopen
MFP22D/MM22B/Z28D 0/AF0
Connection technologyAF0 = Metric cable entryAF1 = With micro-style connector for
DeviceNet and CANopenAF2 = M12 plug connector for PROFIBUSAF3 = M12 plug connector for PROFIBUS +
M12 plug connector for 24 VDC supply
Method of connection0 = � / 1= �
Connection moduleZ18A = For InterBusZ28D = For PROFIBUSZ38A = For DeviceNet and CANopen
MOVIMOT® inverter