Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems...

12
Mosaic System-Control Room Technology Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479

Transcript of Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems...

Page 1: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Mosaic System-Control Room Technology

Illuminated Pushbuttonand

Pushbutton Switch

LT 1879 / LT 2479LS 1879 / LS 2479

Page 2: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

The contents may be subject to modification for the purpose of technical improvement. The general regulations applicable to installationand commissioning must be observed. No warranty can be accepted.

The products described in this brochure are intended for industrial use and meet the requirements laid down bythe EU directive 73 /23 /EU (issued by the Council for Coordination of the Regulations of EU Member Countries regarding the electrical equipment for use within certain voltage limits, revised by directive 93 / 68 EU issued by the council).

Page 3: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Illuminated Pushbutton and Pushbutton Switch 3

Contents Page

Application 4

Design 4

Switching Elements 4

Collars 4

Illumination 4

Mounting 4

Technical Characteristics 5

Diagrams 6

Collars, Filament Lamps and LED Complement 8

Dimension Drawings 9

Table of Contents

Page 4: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

4 Illuminated Pushbutton and Pushbutton Switch

Mosaic panel mounting, rear view

Application

The illuminated pushbuttons and pushbutton switches of the series”79” have been developed for the use in Mauell’s M18 and M24mosaic systems. Depending on the switching elements used thedevices can be employed for the direct switching of relays orautomatic control processes, the activation of electronic modulesas well as the connection and disconnection of control, closed-loopcontrol and measuring circuits.

Design

The enclosed switching elements and the switching plunger areinserted in a robust plastic case together with the lamp or LEDadapters. The collar carrier with the collar is clipped on to theswitching plunger. Collar carrier and collars are conected by meansof a snap-on locking mechanism so that they can be easilyreplaced. The illuminated pushbuttons and pushbutton switchescome in an enclosed case with a multi-core cable and plugconnector and are completely wired up.

Switching Elements

The device types -01 to -04 have double-break snap-actionmechanisms with gold-plated silver contacts. A maximum of 4 NOand 4 NC contacts is possible. The device types -11 to -13 areequipped with low-level switching elements, specially developed forthe activation of electronic modules. These switching elementsoffer the advantage of a high switching reliability at themicroampere and microvolt level, a long service life, a highlyconstant contact resistance, and a practically bounce-freeoperation.

They have single-break momentary contacts with 4-fold pick-off.Available are either 1 NO and 1 NC contact, or 2 NO and 2 NCcontacts.

Collars

Square or round collars of 15mm or 9mm, available as illuminatedor non-illuminated version and in different colours.

Illumination

Devices of the ”18” series can be equipped with one filament lampor one LED with T 5.5 cap. Devices of the ”24” series can beequipped with one filament lamp or one LED with T 6.8 cap, or twofilament lamps or two LEDs with T 5.5 cap.If LEDs are used, we recommend the use of clear collars. Collarsand lamps can be accessed from the front for easy replacementeven if the device is already installed.

Mounting

The devices are simply inserted from the rear in the standardsquares of the mosaic board and then locked with the front tiles.

Page 5: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Illuminated Pushbutton and Pushbutton Switch 5

Technical Characteristics

Type of protection Housing: IP 40

Solder connections: IP 00

Test voltageSnap-action mechanism 2.000VAC, 1min.Low-level element 1.000VAC, 1min.

Rated insulation voltage acc. to VDE 0110Snap-action mechanism 250V, insulation group B (with

cable and plug: 110VDC/125VAC)

Low-level element 60V, insulation group B

Switching capacitySnap-action mechanism 5A at 220V, cos ϕ = 1

3 A at 220 V cos ϕ = 0.3 ind.

Direct voltage, non-inductiveV 24 48 60 125 250A 4 2 1.5 0.5 0.25

Direct voltage L /R = 30msV 24 48 60 125 250

A 2 1 0.7 0.2 0.1

Low-level element 100mA, 50VAC, 72 VDC

Contact pressureSnap-action mechanism 0.3 N approx.

Low-level element 0.4 N approx.

Contact materialSnap-action mechanism Silver with 10µm gold plate

Low-level element Bronze with 5µm gold plate

Contact resistanceLow-level element 15 mΩ

Mechanical lifeSnap-action mechanism 2x106 operations

Low-level element 5x106 operations

The devices are supplied with multi-core plastic-insulated cables(2.20m length) and multipole plug connectors for the connection toterminal blocks according to our brochure ”Cables with PlugConnectors, Terminal Blocks”. For other types of connection, thedevices can be supplied without cables and an open case to allowaccess to the terminals.

Collar Colours

Illuminated Clear, white, red, yellow andblue

Non-illuminated Black, white, anthracite andgrey

Filament Lamps

With T5.5 cap

24V 28V 30V 48V 60V 70V

Clear 1.2W, 0.6W 0.6W 1.2W, 0.6W 1.2W 1.2W 1.4W

Red 1.2W 1.2W 1.2W 1.2W 1.2W

With T6.8 cap

24V 28V 30V 48V 60V 70V

Clear 1.2W 1.2W 1.2W 1.2W 1.2W 1.4W

Red 1.2W 1.2W 1.2W 1.2W 1.2W 1.4W

Yellow 1.2W 1.2W 1.2W 1.2W 1.2W

Green 1.2W 1.4W

LEDs

With T5.5 or T6.8 caps

12V, 12.5mA Red, green or yellow (red /green through reversion)

24V, 12.5mA Red, green or yellow (red /green through reversion)

Accessories

Lamp extractor For lamps and LEDs

Page 6: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

6 Illuminated Pushbutton and Pushbutton Switch

Diagrams

Page 7: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Illuminated Pushbutton and Pushbutton Switch 7

Page 8: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

8 Illuminated Pushbutton and Pushbutton Switch

Collars, Filament Lamps and LED Complement

LT/LS1879 LT/LS2479

Page 9: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Illuminated Pushbutton and Pushbutton Switch 9

Dimension Drawings

Page 10: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

10 Illuminated Pushbutton and Pushbutton Switch

Notes

Page 11: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

Illuminated Pushbutton and Pushbutton Switch 11

Power Station Control and Process ControlAutomation system ME 400Process control system ME 4012Data sheets ME 4012Fail-safe control system ME 4002SCouplers, electrical power controllersElectronic control system ME 4002Data sheets: Electronic control system ME 4002Data sheets: Electronic control system ME 4022Electronic measuring and monitoring system ME 7002

Application Reports• Digital turbine control• Optimal control of industrial steam generators• Sample documentation ME 4012

(Flue gas desulfurization, absorber circulation)• Computer-aided design with the

process control system ME 4012• Reference list of completed process control installations

Power Distribution Control / Remote ControlRemote control system ME 800Microprocessor remote control system ME 8008Terminal control system ME 8010Terminal control system ME 8012Remote control system ME 8012Microprocessor remote control system ME 8018Power distribution control system ME 6005

Alarm and Event Recording SystemsEvent data acquisition system ME 300System description ME-NETAlarm and event recording system ME 2015Criterion computer ME 2015KAlarm and event recording system ME 2025Electronic alarm system ME 3008

Mosaic Systems /Control Room TechnologyMosaic systems MMosaic systems KMosaic systems TMosaic systems MKMosaic accessory partsDisplay elements

Electronic Standard DeviceDisplay units ANZDC voltage monitoring unit GEÜ 02 / GESÜ 02Alarm and event recording system ME 2025 / 96Compact alarm system ME 3009Illuminated annunciator system ME 3012Distributed alarm system ME 3014Alarm system ME 3010Intelligent alarm system ME 30Illuminated indicator board Type LCables with connectors, terminal blocksAnnunciator relaysIlluminated annunciator relayMosaic indicator boardsCrosspoint relaysCouplersTime-delay relaysIlluminated pushbuttons / switchesAnnunciator moduleFlasher unit / flasher amplifiersElectronic flasher unitTest switchSwitches and pushbuttons for auxiliary circuitsStandard rack systemIlluminated pushbuttons, eyeball indicatorsReversing thyristor controllersCouplersStart-up and brake control modulesEmergency OFF devicesTwo-hand safety relaysSafety door monitorElectronic controllers

Technical Brochures Available

Page 12: Mosaic System-Control Room Technology€¦ · Mosaic Systems/Control Room Technology Mosaic systems M Mosaic systems K Mosaic systems T Mosaic systems MK Mosaic accessory parts Display

4.1879.02E99IIIII

Representatives

INTERNATIONAL

Mauell AGFurtbachstraße 17CH-8107 Buchs / SwitzerlandTel. +41 (0)1/844 48 11Fax +41 (0)1/844 44 56

Mauell GmbHBrown-Boveri-Straße 8/12A-2351 Wiener Neudorf / AustriaTel. +43 (0)22 36/2 11 01- 0Fax +43 (0)22 36/2 11 01 - 30

Helmut Mauell B.V.Postbus 89NL-3840 AB Harderwijk / NetherlandsTel. +31 (0)3 41/41 15 80Fax +31 (0)3 41/41 15 81

Mauell Ltd.P.O. Box No. 183GB-Calne, SN11 9BZ, Wiltshire/Great Britain Tel. +44 (0)12 49/81 20 46Fax +44 (0)12 49/81 70 96

Mauell ABFredsforsstigen 22-24S-168 66 Bromma/SwedenTel. +46 (0)8/98 60 05Fax +46 (0)8/98 56 50Telex 10 428

Mauell Corporation31 Old Cabin Hollow RoadDillsburg PA 17019/USATel. +1717 4 32 86 86Fax +1717 4 32 86 88

Helmut Mauell do Brasil Ltda.Caixa Postal 5406850-000 Itapecerica da Serra São Paulo/BrazilTel. +55 (0)11 79 47-17 77Fax +55 (0)11 79 47-17 74

Helmut Mauell Pty LtdLevel 11100 Walker StreetNorth Sydney NSW 2060/Australia Tel. +61 (0)2/9460 1855Fax +61 (0)2/9460 0616

J. LorenteApartado de Correos 5E-Las Rozas (Madrid)/SpainTel. +34 (0)9/16 30 07 50Fax +34 (0)9/16 30 33 09

N.V. Rogelec S.P.R.L.Nieuwevaart 101B-9000 Gent/BelgiumTel. +32 (0)9/2 25 54 06Fax +32 (0)9/2 23 44 10

Ingeniørfirmaet K. Fritzbøger A/SKongevejen 79DK-2840 Holte/DenmarkTel. +45 45 41 45 31Fax +45 45 41 45 32

Berggård Amundsen & Co. A/SPostboks 25, ManglerudN-0612 Oslo 6/NorwayTel. +47 (0)22/68 10 00Fax +47 (0)22/68 98 43Telex 76 031

Fortum Engineering LtdRajatorpantie 8, VantaaFIN-01019 Vantaa/FinlandTel. +358 (0)9/8561 4436Fax +358 (0)9/8561 4418

SERVICIOS Y SUMINISTROS S.A.Casilla Correo 5239RA-1000 Buenos Aires/ArgentinaTel. +54 (0)11/4796-12 80Fax +54 (0)11/4791-86 65

Helmut Mauell GmbHMagyarországi IrodaH-1221 Budapest/HungaryTanító u. 19/ATel. +36 (0)1/424 00 97Fax +36 (0)1/424 00 98

SULTAN INTERNATIONALP.O. Box 3486Abu Dhabi U.A.E.Tel. +9712/22 44 11Fax +9712/22 44 55

KANA CONTROLS GEN. TRADING & CONTRACTING CO. w.l.l.Plot 28-30 Street No.31Al Rai Industrial Area KuwaitP. O. Box 25 59 3 Safat13116 KuwaitTel. +9 65/47 41 3 7 3-76Fax +9 65 /47 41 537

GERMANY

Helmut Mauell GmbHAm Rosenhügel 1-7D-42553 Velbert Tel. +49 (0)20 53/1 30Fax +49 (0)20 53/1 34 03

Helmut Mauell GmbHWerk WeidaPapiermühlenweg 10D-07570 WeidaTel. +49 (0)3 66 03/4 80Fax +49 (0)3 66 03/4 83 10