MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH ......outside of front wall framing. 2 x 4s must be used...

2
Specifications Additional information can be found online at www.heatnglo.com or www.fireplaces.com 5-7/8" [149] 31-1/8" [791] 40-1/2" [1029] 16" [406] 56-1/2" [1435] 12" [305] 16-3/4" [425] 29-1/4" [743] 37" [940] 40" [1016] 1" [25] 1" [25] 42" [1067] 9-3/4" [248] 7-3/8" [187] 1" [25] 12-3/4" [324] 23-1/2" [597] 1/2"[13] MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREBOX OPENING NORTHSTAR-C Actual Framing Actual Framing Actual Framing Actual Framing 37 x 31-1/8 40 42-1/2 40 42-1/2 40-1/2 56-3/4 23-1/2 24* Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. Northstar-C Wood-burning Fireplace Northstar-C Top View Front View Right Side View *If interior of chase will be drywalled, add the thickness to this measurement.

Transcript of MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH ......outside of front wall framing. 2 x 4s must be used...

Page 1: MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH ......outside of front wall framing. 2 x 4s must be used for the header and framing above the header to maintain pipe clearances. Double studs

Specifications

Additional information can be found online at www.heatnglo.com or www.fireplaces.com

12-3/4"[324]

23-1/2"[597]

1/2"[13]

5-7/8"[149]

31-1/8"[791]

40-1/2"[1029]

16" [406]

56-1/2"[1435]

12"[305]

16-3/4"[425]

29-1/4" [743]

37" [940]

40" [1016] 1"[25]

1"[25]

42" [1067]

9-3/4"[248]

7-3/8"[187]

1" [25]

12-3/4"[324]

23-1/2"[597]

1/2"[13]

5-7/8"[149]

31-1/8"[791]

40-1/2"[1029]

16" [406]

56-1/2"[1435]

12"[305]

16-3/4"[425]

29-1/4" [743]

37" [940]

40" [1016] 1"[25]

1"[25]

42" [1067]

9-3/4"[248]

7-3/8"[187]

1" [25]

MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREBOX OPENING

NORTHSTAR-CActual Framing Actual Framing Actual Framing Actual Framing

37 x 31-1/840 42-1/2 40 42-1/2 40-1/2 56-3/4 23-1/2 24*

Please consult the manufacturer’s installation manual for all details and requirements before making a final

design layout decision.

Northstar-CWood-burning Fireplace

Northstar-C

Top View

Front View Right Side View

*If interior of chase will be drywalled, add the thickness to this measurement.

Page 2: MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH ......outside of front wall framing. 2 x 4s must be used for the header and framing above the header to maintain pipe clearances. Double studs

XXXXXXSpecifications

WS/HNG/NORTHSTAR-C_1119

PRODUCT LISTING CODES

US UL 127

CAN ULC-S610-M87

Additional information can be found online at www.heatnglo.com

Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.

Lakeville, MN Phone: (888) 427-3973 Web: www.heatnglo.com

24*[610]

42-1/2" [1080]54-1/2"[1384]

16"[406]

42-1/2"[1080]54-1/2" [1384]

16"[406]

24"*[610]

24"*[610]

54-1/2"[1384]

16" [406]

48" [1219]

89-1/2"[2273]42-1/2"

[1080]

63-5/16" [1608]

44-3/4"[1137]

24-1/2"*[622]

24-1/2"*[622]

Across a corner

In an exterior chase

*If interior of chase will be drywalled, add the thickness to this measurement.

Along a wall

As a divider

Faceplate to sidewall 16 inches

42-1/2"[1080]

FasciaOuter Shell Flange

Protective metalhearth strip

Tile,marble or other non-combustible finish material

Minimum 2" [51] Cement Board or equivalent, (or one piece HX4)

Minimum 20" [508] in front and 8" [203] on sides to fuel opening

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . .

. . .

. . .

. .

Non-combustible material supplied with unit.

. . .

. . .

. . .

. .

Non-combustible sealant or groutTile,marble or other non-combustible finish material

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8" [203] minimum from each side offuel opening

41" [1041]20" [508]

(ceiling)

(roof)

(ceiling)

2" (51mm) min.

Attic Insulation

Shield

Ceiling Firestop(attic)

Storm Collar

Roof Flashing

2" min.(51mm)

2" (51mm) min.

2" (51mm) min.

Ceiling Firestop Offset/Return with hanger straps

2"(51mm)

min. 2"(51mm) min. Must have 2" (51mm)

minimum clearanceto header

Electrical wires must be a minimum of 16" (406mm) from top

1" (25mm) to side of appliance

1/2" (13mm) to backof appliance

0"to floor

36" (914mm) Top of appliance to

ceilingChimney Air Kit required with SL chimneyDuraPlus base plate required with Duraplus chimney

2 x 4 header

12" (305 mm)

3/4"(19 mm)maximum

Grid represents 1" squares

60" (1524mm)Measured up from

the base of the fireplace.

Non-combustible Decorative Facingsuch as: Steel, iron,brick, tile, concrete,slate, tile, plasters.DO NOT cover anyair openings in the face of the fireplace.

48" (1219 mm)Measured up from

the base of the fireplace.

Non-combustible board

Combustible mantel may be positioned anywhere within the grid area.

Seal joint withnon-combustiblesealant to prevent heat from being drawn into the wall cavity

Position combustible mantel 60" (1524 mm) from base of fireplace

12"(305 mm)

56-3/4"(1441 mm)

24" *(610 mm) 48-1/2"

(1232 mm)

42-1/2"(1080 mm)

The finished cavity depth must be no less than 24" (610 mm) from the finished backwall to the outside of front wall framing.

2 x 4s must be used for the header and framing above the header to maintain pipe clearances.

Double studs to catch non-combustible board and wall facing material.

*If interior of chase will be drywalled, add the thickness to this measurement.

Allow 12" minimum cavity depth if using an elbow/bend for the required outside air. Duct may be installed on either side.

14-1/2" (368 mm) for SL300 Chimney16" (406 mm) for DuraPlus Chimney

Non-combustible mantle may be positioned as low as 1 in. above the Fascia (Fronts) and 12 in. deep or from the base of the fireplace 38 in. up.

12"(305 mm)

FRAMING DIMENSIONSAPPLIANCE LOCATION

Specifications

MANTEL PROJECTIONS

HEARTH EXTENSION

HEARTH EXTENSION CONSTRUCTION

Northstar-C

CLEARANCE TO COMBUSTIBLES

You must use 2x4’s for the header in order to maintain clearances to the pipe.

See install manual figure 7.8 for raised hearth extention.