EXTERIOR WALL CLADDING - Huber Engineered Woods · exterior wall cladding window header stud wall...

13

Transcript of EXTERIOR WALL CLADDING - Huber Engineered Woods · exterior wall cladding window header stud wall...

EXTERIOR WALL CLADDING

AIR / DRAINAGE CAVITY PER

CLADDING MANUF.

RECOMMENDATIONS.

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION.

ZIP SYSTEM SHEATHING

"INNIE" FLANGED

WINDOW

JACK AND KING STUD

FRAMING AT WINDOW

ROUGH OPENING

STUD WALL FRAMING

TYPICAL WALL CAVITY

INSULATION

WINDOW EXTENSION

BOX BEYOND PER

ARCH. DETAILS

LOW-EXPANDING FOAM SEALANT OR

100% SILICONE, POLYURETHANE, OR

BUTYL SEALANT. USE BACKING ROD

AS NEEDED.

WINDOW SEALANT BEHIND

WINDOW JAMB FLANGE

6-INCH ZIP SYSTEM FLASHING

TAPE. 3.75-INCH ZIP SYSTEM

SEAM TAPE OR LIQUID FLASH

MAY ALSO BE USED.

EXTERIOR WINDOW TRIM PER

ARCHITECTURAL OR WINDOW

MANUF. DETAILS.

TYPICAL WALL CAVITY INSULATION (NOT CLOSED-CELL

FOAM). DO NOT USE POLYETHYLENE SHEETING, FOIL FACED

BATTS OR OTHER CLASS I VAPOR RETARDER ON THE INSIDE

FACE OF WALL FRAMING WHEN USING THIS DETAIL.

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® TYPICAL "INNIE" WINDOWJAMB DETAIL K-2

ZIP SYSTEM SHEATHING

WINDOW EXTENSION

BOX BEYOND PER ARCH.

DETAILS

EXTERIOR WALL CLADDING

WINDOW HEADER

STUD WALL FRAMING

TYPICAL WALL CAVITY

INSULATION

AIR / DRAINAGE CAVITY PER

CLADDING MANUF.

RECOMMENDATIONS.

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION.

WINDOW SEALANT BEHIND

WINDOW HEAD FLANGE (ONLY

USE POLYURETHANE, BUTYL OR

100% SILICONE SEALANTS)

WINDOW TRIM PER

ARCHITECTURAL DETAILS

LOW-EXPANDING FOAM

SEALANT OR 100% SILICONE,

POLYURETHANE, OR BUTYL

SEALANT. USE BACKER ROD

AS NEEDED.

EXTERIOR WINDOW TRIM PER

ARCHITECTURAL OR WINDOW

MANUF. DETAILS.

"INNIE" FLANGED WINDOW

TYPICAL WALL CAVITY INSULATION (NOT CLOSED-CELL

FOAM). DO NOT USE POLYETHYLENE SHEETING, FOIL FACED

BATTS OR OTHER CLASS I VAPOR RETARDER ON THE INSIDE

FACE OF WALL FRAMING WHEN USING THIS DETAIL.

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

6-INCH ZIP SYSTEM FLASHING

TAPE. 3.75-INCH ZIP SYSTEM

SEAM TAPE OR LIQUID FLASH

MAY ALSO BE USED.

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® TYPICAL "INNIE"WINDOW HEAD DETAIL K-3

EXTERIOR WALL CLADDING

AIR / DRAINAGE CAVITY PER

CLADDING MANUF.

RECOMMENDATIONS.

ZIP SYSTEM SHEATHING

"OUTIE" FLANGED WINDOW

JACK AND KING STUD

FRAMING AT WINDOW

ROUGH OPENING

STUD WALL FRAMING

TYPICAL WALL CAVITY INSULATION

LOW-EXPANDING FOAM SEALANT OR

100% SILICONE, POLYURETHANE, OR

BUTYL SEALANT. USE BACKING ROD

AS NEEDED.

WOOD BLOCKING PERIMETER

OF WINDOW ROUGH OPENING

TO MATCH FACE OF EXTERIOR

FOAM INSULATION

WINDOW SEALANT BEHIND

WINDOW JAMB FLANGE

CONTINUOUS BEAD OF

SEALANT (ONLY USE

POLYURETHANE, BUTYL OR

100% SILICONE SEALANTS)

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION

INSTALLED DIRECTLY TO ZIP

SYSTEM SHEATHING.

TYPICAL WALL CAVITY INSULATION (NOT CLOSED-CELL

FOAM). DO NOT USE POLYETHYLENE SHEETING, FOIL FACED

BATTS OR OTHER CLASS I VAPOR RETARDER ON THE INSIDE

FACE OF WALL FRAMING WHEN USING THIS DETAIL.

ZIP SYSTEM TAPE, ZIP SYSTEM

LIQUID FLASH OR OTHER

CODE-RECOGNIZED PAN FLASHING

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® TYPICAL "OUTIE"WINDOW JAMB DETAIL K-6

ZIP SYSTEM SHEATHING

"OUTIE" FLANGED WINDOW

EXTERIOR WALL CLADDING

WINDOW HEADER

STUD WALL FRAMING

AIR / DRAINAGE CAVITY PER

CLADDING MANUF.

RECOMMENDATIONS.

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION.

CONTINUOUS BEAD OF SEALANT

(ONLY USE POLYURETHANE, BUTYL

OR 100% SILICONE SEALANTS)

LOW-EXPANDING FOAM SEALANT OR

100% SILICONE, POLYURETHANE, OR

BUTYL SEALANT. USE BACKER ROD

AS NEEDED.

WOOD BLOCKING PERIMETER OF

WINDOW ROUGH OPENING TO

MATCH FACE OF EXTERIOR FOAM

INSULATION

WINDOW SEALANT BEHIND

WINDOW HEAD FLANGE

DRAINAGE MAT OR FUR STRIPS

(1/8-INCH RECOMMENDED)

DRAINAGE MAT OR FUR STRIPS

(1/8-INCH RECOMMENDED)

CLOSED-CELL WALL CAVITY

INSULATION, FOIL-FACED BATTS

OR CLASS I VAPOR RETARDER

DRYING / DRAINAGE (1/8-INCH RECOMMENDED) MUST BE PROVIDED

BETWEEN FOAM INSULATION AND ZIP SYSTEM SHEATHING FOR

CLOSED-CELL WALL CAVITY INSULATION OR WHEN USING

FOIL-FACED BATTS, POLYETHYLENE SHEETING OR OTHER CLASS I

VAPOR RETARDER ON THE INSIDE FACE OF WALL FRAMING.

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

6-INCH ZIP SYSTEM FLASHING TAPE.

3.75-INCH ZIP SYSTEM SEAM TAPE

OR LIQUID FLASH MAY ALSO BE

USED.

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® OUTIE WINDOW HEAD W/CLOSED-CELL INSULATION & EXTERIOR FOAM K-7

EXTERIOR WALL CLADDING

AIR / DRAINAGE CAVITY PER

CLADDING MANUF.

RECOMMENDATIONS.

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION.

ZIP SYSTEM SHEATHING

"OUTIE" FLANGED WINDOW

JACK AND KING STUD

FRAMING AT WINDOW

ROUGH OPENING

STUD WALL FRAMING

CLOSED-CELL WALL CAVITY

INSULATION, FOIL-FACED BATTS OR

CLASS I VAPOR RETARDER

DRAINAGE MAT OR FUR STRIPS

(1/8-INCH RECOMMENDED)

LOW-EXPANDING FOAM SEALANT OR

100% SILICONE, POLYURETHANE, OR

BUTYL SEALANT. USE BACKER ROD

AS NEEDED.

WOOD BLOCKING PERIMETER

OF WINDOW ROUGH OPENING

TO MATCH FACE OF EXTERIOR

FOAM INSULATION

WINDOW SEALANT BEHIND

WINDOW JAMB FLANGE

CONTINUOUS BEAD OF

SEALANT (ONLY USE

POLYURETHANE, BUTYL OR

100% SILICONE SEALANTS)

DRAINAGE MAT OR FUR STRIPS

(1/8-INCH RECOMMENDED)

DRYING / DRAINAGE (1/8-INCH RECOMMENDED) MUST BE PROVIDED

BETWEEN FOAM INSULATION AND ZIP SYSTEM SHEATHING FOR

CLOSED-CELL WALL CAVITY INSULATION OR WHEN USING

FOIL-FACED BATTS, POLYETHYLENE SHEETING OR OTHER CLASS I

VAPOR RETARDER ON THE INSIDE FACE OF WALL FRAMING.

6-INCH ZIP SYSTEM FLASHING

TAPE. 3.75-INCH ZIP SYSTEM

SEAM TAPE OR LIQUID FLASH

MAY ALSO BE USED.

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® OUTIE WINDOW JAMB W/CLOSED-CELL INSULATION & EXTERIOR FOAM K-8

STUD WALL FRAMING

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION

BRICK VENEER CLADDING

MIN. 1-INCH AIR SPACE

PER LOCAL CODE

SLAB-ON-GRADE

ZIP SYSTEM SHEATHING

TYPICAL WALL CAVITY INSULATION (NOT CLOSED-CELL

FOAM). DO NOT USE POLYETHYLENE SHEETING, FOIL FACED

BATTS OR OTHER CLASS I VAPOR RETARDER ON THE INSIDE

FACE OF WALL FRAMING WHEN USING THIS DETAIL.

BRICK TIES MUST ATTACH THROUGH

FOAM INTO WALL STUD FRAMING

TOP EDGE OF FLASHING TAPED

WITH ZIP SYSTEM TAPE OR LIQUID

FLASH

CODE APPROVED BASE

FLASHING

WEEP HOLES (AS PRESCRIBED

BY LOCAL BUILDING CODE)

TYPICAL WALL CAVITY

INSULATION

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® TYPICAL BRICK BASEFLASHING DETAIL K-11

STUD WALL FRAMING

TOP EDGE OF FLASHING TAPED

WITH ZIP SYSTEM TAPE OR LIQUID

FLASH

CODE APPROVED BASE

FLASHING

WEEP HOLES (AS PRESCRIBED

BY LOCAL BUILDING CODE)

MECH. FASTENED EXTERIOR

RIGID FOAM INSULATION.

BRICK VENEER CLADDING

MIN. 1-INCH AIR SPACE

PER LOCAL CODE

SLAB-ON-GRADE

DRAINAGE MAT OR FUR

STRIPS (1/8-INCH

RECOMMENDED)

CLOSED-CELL WALL CAVITY

INSULATION, FOIL-FACED BATTS

OR CLASS I VAPOR RETARDER

ZIP SYSTEM SHEATHING

BRICK TIES MUST ATTACH THROUGH

FOAM INTO WALL STUD FRAMING

DRYING / DRAINAGE (1/8-INCH RECOMMENDED) MUST BE PROVIDED

BETWEEN FOAM INSULATION AND ZIP SYSTEM SHEATHING FOR

CLOSED-CELL WALL CAVITY INSULATION OR WHEN USING

FOIL-FACED BATTS, POLYETHYLENE SHEETING OR OTHER CLASS I

VAPOR RETARDER ON THE INSIDE FACE OF WALL FRAMING.

TYPICAL WALL CAVITY INSULATION

CLOSED-CELL FOAM, FOIL-FACED BATTS,

POLY SHEETING OR OTHER CLASS 1

VAPOR RETARDER

"INNIE" MOUNTED FLANGED WINDOW

"OUTIE" MOUNTED FLANGED WINDOW

07-09-2012

Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262

DRAWING NOT TO SCALE

These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to

every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.

ZIP SYSTEM® BRICK FLASHING W/CLOSED-CELL INSULATION & EXTERIOR FOAM K-13