Micropoint 2 High Output - Cooper Lighting & Safety · 10 2.5 8.0 21.0 8 4.4 7.7 19.7 6 7 7.0 18...
Transcript of Micropoint 2 High Output - Cooper Lighting & Safety · 10 2.5 8.0 21.0 8 4.4 7.7 19.7 6 7 7.0 18...
EmergencyMicropoint 2 High Output
Micropoint 2 high output is an extension to the current Micropoint 2 range.
It remains a high specification competitively priced emergency LED luminaire. Micropoint 2 high output utilises the latest LED and optic technology to provide an unobtrusive, high quality luminaire for indoor use where aesthetics and high performance are of prime importance. Micropoint 2 high output has been designed for high ceiling applications, to meet the requirements of the NFPA 101 standards for 10.8lux (average) in an escape route application and also to meet the requirements for the specific locations as stated within BS 5266-1:2011. Micropoint 2 high output has been designed for ease of installation, reduced power consumption and minimal maintenance, reducing the TCO (total cost of ownership) without compromising on aesthetics.
• Versatile multi-functional use (high ceiling, NFPA 101 escape route and specific locations as stated within BS 5266-1:2011)
• Low power consumption reducing cost of ownership
• Excellent spacing reducing the quantity of fittings required
• 60,000 hour life LED for reduced maintenance
• Self-contained, slave, self-test and addressable testing options
Micropoint 2 High OutputEmergency
Lamp and Control Gear Options
• 1 x High power 2.5W white LED
• Consumption – 7.2VA/3.9W
Materials
• Luminaire Head - polycarbonate
• Remote Gear Pod - flame retardant ABS
• Battery Box– Steel powder coated in RAL9016 (self-contained version)
• Battery – NiCd (self-contained version)
Installation Notes
• Flush mount
• Spring retaining clips for surface installation (install from below ceiling)
• Cut-out diameter 64mm
Options
• Non-maintained
• Intellem Self-test
• CGLine+ addressable test
• Easicheck addressable test
• Central slave versions
• CEAG slave versions
Specification
Self-contained - To specify: High performance LED self-contained emergency luminaire with 2.5W LED suitable for specific locations as described within BS 5266-1:2011, with remote gear pod and battery box capable of installation through luminaire ceiling cut-out and NiCd Battery, as per Micropoint range, part no. ____________
Self-test/Addressable test/Slave - To specify: High performance LED intelligent self testing/addressable test/slave system compatible emergency luminaire with 2.5W LED suitable for specific locations as described within BS 5266-1:2011, with remote gear pod and battery box (self-contained) capable of installation through luminaire ceiling cut-out, as per Micropoint range, part no. ____________
Photometric Data
Dimensions
Mode Mount Lux level height directly (m) under
Escape route 2m wide 1 lux min
Self contained/ 15.5 1 4.1 22.7
slave 14 1.3 6.4 22.7
12 1.7 7.9 22.1
10 2.5 8.0 21.0
8 4.4 7.7 19.7
6 7 7.0 18
63mm
29mm
90mm
64mm
41mm
41mm291mm
Micropoint 2 High OutputEmergency
Corridor and refuge area Plant room
Catalogue NumbersSystem Mode Cat No
Non-maintained 3 Hour self-contained MP2HI3HNon-maintained 3 Hour self-contained CGLine+ MP2HI3HCGLNon-maintained 3 Hour self-contained Easicheck 2 MP2HI3HEC2Non-maintained 3 Hour self-contained Intellem self-test MP2HI3HISMains Slave 230V MP2HI230230V CEAG Slave MP2HI230CGSMains Slave 230V Easicheck MP2HI230EC
Kitchen Reception areas
First aid rooms Treatment rooms
Refuge area5 Lux min
Emergency exit push bar
5 Lux min
Fire call point15 Lux min
Corridor and refuge area
Fire equipment15 Lux min
Plant rooms15 Lux min
(in plane of visual task)
Plant room
Fire equipment15 Lux minKitchens
15 Lux min(horizontal on working plane,
switches and cutouts readily visible)
Kitchen
Fire equipment15 Lux min Reception areas
15 Lux min
Reception areas
First aid rooms
First aid rooms15 Lux min
(horizontal on working plane)
Treatment rooms
Treatment rooms50 Lux min