Specifications
Additional information can be found online at www.heatnglo.com
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
Actual Framing Actual Framing Actual Framing Actual Framing
Please consult the manufacturer’s installation manual for all details and requirements before making a final
design layout decision.
MEZZO3636" Direct Vent Gas Fireplace
MEZZO36
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MEZZO36Actual Framing Actual Framing Actual Framing Actual Framing
35-1/2 x 12-1/246-3/16 48-1/4 46-3/16 48-1/4 41-3/4 42 17-1/8 18-1/4
8-9/16" [218]
1" [25]46-3/16" [1173]
17-1/8"[435]
18-5/8"[473]
oCENTERED ON APPLIANCE
8" [203]
41-3/4" [1061]
2-3/8"[60]
8-9/16"[218]2-3/4"
[70]
23-3/4"[603]
36-5/8"[930]
39-1/4" [997]49-1/2" [1257]
15-5/8" [397]
42-1/2"[1080]
24-1/2"[622]
8-7/8" [225]
7-1/4"[184] GAS ACCESS
ELECTRICAL ACCESS
4" [102]
8-9/16" [218]
63" [1600]
Top
FrontLeft Right
BEFORE FRAMING, PLEASE NOTE:
A minimum of 18" of vertical venting is required before attaching any elbow to the appliance.
-
MEZZO36Decorative Fronts Dimensions and Framing
FRONT DIMENSIONS
FINISHED OPENING DIMENSIONS
Clean Face Trim
Inside Fit Method (Clean Face Trim)
Overlap Fit Method (Loft Forge, Quattro)
Loft Forge Front Quattro Front
• Rectangularholesonbottomofaccesspanelshouldbecovered.
• Approvedfor0"-4"finishingmaterialoninsidefitmethod
• Iffinishingmaterialsare0-1”thick,theoutertrimringshouldbeadjustedoutsothatthetrimringoverlapsthefinishingmaterial.Thisisintendedtoprovidethecleanestlook.
• Iffinishingmaterialsare1-4”thick,installthetrimringallthewayin.Finishingmaterialsmaynotextendpasttheoutsideedgeofthetrimring.
• Rectangularholesonbottomofaccesspanelmustbeexposed.
• ONLYapprovedfor0"-1"finishingmaterialonoverlapfitmethod
• Rectangularholesonbottomofaccesspanelmustbeexposed.
• ONLYapprovedfor0"-1"finishingmaterialonoverlapfitmethod
25"[635]
24"[610]
13-1/8"[333]
16-3/4"[425]
40-5/16" [1024]
39" [991]
37-3/16" [945]
5/8" [16]
26-1/4"[667]
7-1/8"[181]
36-3/4" [933]42-3/4" [1089]
13"[330]
19"[483]
27-1/4"[692]
5-7/8"[149]
36-7/16" [926]45-5/8" [1159]
12-1/2"[318]
21-3/8"[543]
29-1/8" [740]
FIREPLACE VIEWING AREA15-3/4"[400]
39-1/8" [994]
FIREPLACE VIEWING AREA17-1/4"[438]
39-1/8" [994]
-
Specifications
GS/HNG/MEZZO36_0420
PRODUCT LISTING CODES
US ANSI Z21.88-2017
CAN CSA 2.33-2017
UL307B
Additionalinformationcanbefoundonlineatwww.heatnglo.com
Productinformationprovidedisnotcompleteandissubjecttochangewithoutnotice.Productinstallationmustadherestrictlytoinstructionsaccompanyingproducttoavoidriskoffireandpotentialinjury.
Lakeville, MN Web: heatnglo.com Phone: 888-427-3973 952-985-6000
MEZZO36
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
APPLIANCE LOCATION
88-1/8"[2239]
62-1/2"[1588]
48-1/4" [1226]**
48-1/4" [1226]**
48-1/4"[1226]**
48-1/4"[1226]**
18-3/4"[476]
24-1/2"[622] 1"[25]
1"[25]
See clearancesin install manual
Refer to install manual for hearth, mantel and wall projection information. If a Passive Heat, Heat-Zone or Heat Out will be installed, refer install manual for instructions.18 in. (457 mm) required when Passive Heat Side Discharge Kit is installed. Refer to the Passive Heat kit instructions for more information.
MANTEL LEG/WALL PROJECTIONS COMBUSTIBLE OR NON-COMBUSTIBLE
WALL PENETRATION
3 ft. maximum4-1/2"minimum
FIREPLACE OPENINGSee Appliance dimension diagram in install manual - Dimension B
Note: Clearance from opening to perpendicular wall
Top View
FIREPLACE OPENINGSee Appliance dimension diagram in install manual - Dimension B
Note: Clearance from opening to perpendicular wall
Top View
7"minimum UNLIMITED
Acceptable on both sides of opening
64"[1626]
10" 12"
63"[1600]
Do not pack withinsulation orother material
* Shows center of vent framinghole for top venting. Center of holeis 1" [25] above center of horizontalvent pipe.
42"[1067]
48-1/4"[1226]
10"[254]
HEADERDEPTH**
18-1/4"[464]
APPLIANCE MAY BE INSTALLED OFF OF FLOOR***
* Adjust framing dimensions for interior sheathing (such as sheetrock)** Header depth not to exceed 3-1/2".*** If appliance is installed off the floor, maintain required clearances to combustibles Construct platform in accordance with local building codes.
48"[1219]
0"
1" [25]
1" [25]
31" [787]Top of
FireplaceOpening to
Ceiling0"
55-1/2"[1410]
Bottom ofFireplace to
Ceiling
MANTEL PROJECTIONS - NON-COMBUSTIBLE
MANTEL PROJECTIONS - COMBUSTIBLE
OVERLAP FIT INSIDE FIT
MEASUREMENTS FROM TOP EDGE OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
67
89
1011
18
MAX.
Measurement from top edge of openingto bottom of appliance = 24-1/2 IN.
MEASUREMENTS FROM TOP EDGE OF THE APPLIANCE OPENING
4
5
6
16
910
18
MAX.
Measurement from top edge of openingto bottom of appliance = 24-1/2 IN.
7
11
MEASUREMENT FROMTOP EDGE OPENING
1820
2326
29
912
63
1
Measurement from top edge opening to bottom of appliance = 24-1/2 IN.
MAX.
MEASUREMENTS FROM TOP EDGE OF THE APPLIANCE OPENING
4
5
6
16
3
2
1
67
89
1011
18
MAX.
Measurement from top edge of openingto bottom of appliance = 24-1/2 IN.
NOTE: All measurements in inches.
WITHOUTPASSIVE HEAT
WITHPASSIVE HEAT
NOTE: All measurements in inches.