Metering Station1
Transcript of Metering Station1
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 1/29
B Y PA N K A J B E L A D I YA G E T- I N S T. ( 9 0 1 4 3 )
Metering StationNew skid of GSPL
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 2/29
Gas metering stations are designed for simultaneous,continuous analysis of the quality and quantity of natural
gas being transferred from terminal.Monitor & manage the natural gas supply in pipes.Measure the flow of gas along the pipeline with theminimum error.
Employ specialized meters to measure natural gas as itflows through the pipeline without impeding itsmovement.
Standards for Measurement: AGA 8: Natural Gas Compressibility AGA 9: Measurement of Gas by Multipath USM AGA 10: Measurement of Speed of soundGPA 2172/2145: Heating Value calculation
Purpose of Metering
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 3/29
New Skid Architecture
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 4/29
New Skid Architecture
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 5/29
New Skid P & ID07. P & ID.pdf
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 6/29
Ultrasonic Flow Meter (USM)
The SeniorSonic is designed forcustody transfer and otherapplications requiring highaccuracy.It measures the flow rate which isdependent on the average fluid velocity & cross sectional area of meter.The basic principle is that soundtraveling with fluid flow will travelfaster than sound traveling againstthe flow.The transient difference is a function
of fluid velocity.
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 7/29
Ultrasonic Flow Meter (USM)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 8/29
Tag FT1880,1890
Make/Model No. Daniel/3400-HA00-451751
Type Senior Sonic Intrusive, Multipath
Line Size 12”
Design/Op. Flow 14150/640-13000 ACMH
Design/Op. Pressure 93.8/60-90 barg
Design/Op. Temperature -5 to 60 /5.6-6.6 Deg. C
Design & Construction AGA-9, ASTM A352 LCC (-46° C) body
Accuracy +/- 0.3% overall including Lab inaccuracy
Supply 24 v DC / 15 watt
Outputs • RS 232/485 – 2 nos. for flow and Diag.• Pulse O/P – 2 nos.• 1 Ethernet port
PROFILER • 12’’ 600# Sch 80 Flow Profiler, MOC SS316
USM Specifications:
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 9/29
Pneumatic Actuator
Cylinder
Piston
Scotch-Yock Spring
Instrument Air Supply
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 10/29
Tag MOVP 1880,1881,1890,1891Make/Model no. Flowserve RG318SR5CNGGE00
Type Single effect, Spring return & pistontype, Scotch Yock
Valve Position on Failuer Fail Close type
Stroke time 1 inch/second (adjustable upto 12seconds)
Operating Temperature 10-45 Deg. C
Operating Pressure 4-6-9
Material of Construction CS for housing,cyl-piston & Alloy steel for Spring
LIMIT SWITCH : P & F Make, Model: NJ2-V3-N,Rating: 24V DC
SOVs: ASCO Make, Model: NF8327A002,
Operating Voltage: 110V DC
Actuator Specifications:
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 11/29
Gas Chromatograph
Fig:- Model 500 Analyzer Functional Block Diagram
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 12/29
GC Controller (2350A) Functions
Valve Activations
Timing AdjustmentsStream SequencesCalibrationBaseline Runs AnalysisStream/Detector Assignments Alarm & Event ProcessingDiagnosticsComputation and
ChromatogramReport GenerationInterface with Other Device
10 Analog I/Ps: all 4-20mA
16 Digital I/Ps:5 to read ModBus Add,5 streram flow alarms22 Digital O/Ps:
6 Analyzer control,8 Driver outputs for solenids5 alarms3 front panel indicator
• Communication: RS-232, RS-422 or RS-485
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 13/29
The Analyzer Detector
Fig:- Schematic Diagram of Analyzer Detector Bridge
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 14/29
Chromatogram
Fig:- Detector Output during Component elution
1. Detector Bridge balanced.2. 1st component begins to
elute3. Peak Concentration of 1 st
Component4. 2nd Component begins to
elute5. Peak Concentration of 2 nd
Component
•
Thus, It separates and measures the individual componentsof gas. (C1, C2,C3, IC4, NC4, IC5, NC5, H2S, COS, TotalSulfur)
• It will calculate Heating value, Specific gravity,compressibility, Wobbe index based on composition.
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 15/29
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 16/29
• FloBoss S600+ Flow Computer Specifications
Processor ColdFire MPC8313 333 MHz with integral
floating point processorOperating System Linux
Memory Flash 256 MB, DRAM 128 MB, SRAM 4 MB
Data Logging The S600+ supports up to 333 days of 10stream reports where monthly, weekly, daily,and hourly reports are each archived asindividual reports.
Communications Configuration Port (located on the bottom of the front panel)
Ethernet (NTWK1, NTWK2)
RS232 (COM3, COM4)
RS422/RS485 (COM5, COM6, COM7)
RS485 (COM9, COM10, COM11, COM12)
USB
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 17/29
• FloBoss S600+ Flow Computer Specifications
I/Os:
Analog Inputs 1 to 5 V, 0 to 5 V, 4 to 20 mA, or 0 to 20mA, opto-isolatedFrequency/Density Inputs dc coupled, opto-isolated, 0 to 10 kHzPulse Inputs — Flow Dual pulse or single pulse train, opto-
isolatedPRT (RTD) Inputs 4-wire only connection using Pt 100
transducers, opto-isolated.HART (P188) Module 12 channels. Each channel can be
configured for point-point or multidropcommunications.
Supply Voltage 20 to 32 Vdc, 30 Vdc nominal, 48 W maximum
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 18/29
Metering panel CP-001(Front View)
FC 1880,1890
Supply Indicating Lamps
Eth. Port
2350A Controller
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 19/29
Metering panel CP-001(Right View)
DI,AI barrires
Sockets
FO to Eth Converter
Relays
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 20/29
Metering panel CP-001(Left View)
Ethernet Switch
S/E converters
Power Supply
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 21/29
PLC Panel
Series 90-30 Pow Supp
CPU 372 PLUS
Genius Bus Control
Comm. For GSPL,DCs
Modbus Master SM for FC,GC
COMMTB: GSPL scada,DCS, FC, GC
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 22/29
• Loop Drawing (PT,TT-1880)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 23/29
• Loop Drawing (FT-1880)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 24/29
• Loop Drawing (ZSH,ZSL-1880)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 25/29
• Loop Drawing (ZSH,ZSL-1880)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 26/29
• Loop Drawing (SOV-1880)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 27/29
• Loop Drawing (SOV-1881)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 28/29
• HMI (Proficy iFIX)
7/28/2019 Metering Station1
http://slidepdf.com/reader/full/metering-station1 29/29
Daily Report Sample0278_001.pdf