Medical Platform - Medical Technology

9

Transcript of Medical Platform - Medical Technology

Page 1: Medical Platform - Medical Technology
Page 2: Medical Platform - Medical Technology

Medical Platform

SUB ZERO EFFECT

UPGRADABLETHROUGH TIME

TECHNOLOGYMADE IN ITALY

Page 3: Medical Platform - Medical Technology

LASER AND PULSED LIGHTIN THE SAME PLATFORMMTONE is an ALL IN ONE platform,upgradable over time as needed, available with High Power Laserand IPL Handpieces: PULSED LIGHT (over 12 different handpieces) – Laser Diode 808 - Laser Nd: YAG - Laser Erbium: YAG - Erbium Laser:GLASS - Q-Switched Laser.

SUB ZERO EFFECT:UNIQUE TECHNOLOGYMADE IN ITALYA unique and exclusive, contact integrated cooling system of MTONE, consisting of double Peltier technology and water, allowing safe treatmentson dark phototypes and tanned skin.Up to -12° C.

APC ADVANCED PULSEDLIGHT TECHNOLOGYA unique method of energy supply,by controlling impulses of pulsed light. Work can be performed in single and burst mode.

HIGH QUALITYCOMPONENTSthe optical and electronic components of the platform and handpieces are of the highest level of quality. The size and appearance of the handpieces are larger than that of others on the market.

Advanced graphical interface with automatic, semi automatic and manual treatment parameter control

REMOTE SERVICEOnline technical assistance from the studio to production site

• Automatic handpiece and treatmentparameter recognition

• Capacitive touch screen displayof 10.1 inches

• Advanced graphical user interfacewith manual, automatic andsemi-automatic treatment parametercontrol

• Quick connect hot swap handpieces• Automatic handpiece detection

and treatment parameters• Compact trolley with optional

container

All In OneScalableCompact

Page 4: Medical Platform - Medical Technology

630-950 nm

580-950nm

530-950nm

530-950nm S.M.T.

420-950nm

808nm

2940nm Er:YAG

1064 nm Nd:YAG

Er:GLASS 1540 nm

Nd:YAGQSWITCHED1064+532 nm

IPL

IPL

IPL

IPL

IPL

Laser

Laser

Laser

Laser

Laser

SOURCEANDWAVELENGTH

HANDPIECE SUGGESTIONS

Permanent hair removal and reduction, all skin types (I-VI) on the Fitzpatrick Scale

Permanent hair removal and reduction, all skin types (I-VI) on the Fitzpatrick scale. In addition, treatment of benign Pigmented Lesions and skin lesions, including scars, stretch marks

Pigmented and vascular lesion treatment, all skin types (I-VI) on the Fitzpatrick Scale

Pigmented and Vascular Lesions Treatment, all skin types (I-VI) on the Fitzpatrick scale. Vascular / PWS lesions, telangiectasias.

Acne vulgaris treatment - all skin types (I-VI) on the Fitzpatrick scale

Permanent hair removal for face and body. Treatment of benign vascular and pigmented lesions

Suitable for use in soft tissues and skin tissue: Skin ResurfacingNeviTelangectasiaSpider veinsActinic keratosesKeloidsKeratosisAcne scars

Treatment of vascular lesions of the body and lower limbs, angiomas, light and fine hair removal, Pseudofollicolitis Barbae Treatment (PFB)

Acne scars, post-surgical or post-traumatic scars, (facial wrinkles)

Pigmented and vascular lesion treatment, skin rejuvenation, *dark tattoo treatment

Whyit’s different:All In One

ForAll SkinType

* This type of treatment is not a medical procedure

Page 5: Medical Platform - Medical Technology

Pulsed light with “APC” technology

APCExtremely effectiveand safe

APC - ADAPTIVE PULSE CONTROLis a unique technology of MT ONE, capable of providing energy homogeneously over the entire duration of the impulse.

Thus, energy peaks are avoided, which are particularly dangerous for the treatment of dark skin. APC has an impulse control of pulsed light for an automatic selection of the best treatment configuration.

APC operates in two ways, single or burst (pulse train), for better efficiency and safety. This function adjusts the correct sequence of pulses together with the energy needed for safe treatment.

APC - with different pulse and wavelength configurations,combined with the powerful contact cooling system and the pure sapphire wave guide, is able to perform comfortable and effective treatmentsfor all skin types.

AC 420

VL-PL 530

SMTSub MillisecondTechnology

HR 580

LP-LV 530

HR 630

SR 580

HR IN MOVING

MTONE has several pulse andwave configurations, combinedwith the powerful contact skincooling system and the wave guidein sapphire - SUB ZERO EFFECT - is able to perform comfortable and effective treatments for all skin typesand conditions.

Peltier thermoelectric cooling, together with the precision of the sapphire optical filter and the exclusive APC (Adaptive Pulse Control) ensure safe treatments and optimal results.

The different handpieces with a wide range of wavelengths for each treatment, thanks to the SUB ZERO EFFECT, is able to maintain a very low skin temperature even during“IN MOVING” procedures.

MTONE with IPL handpieces has three different pulse configurations for the emission of energy, in order to adapt perfectly to the needs of all difficult treatment conditions, such as thinhair or dark skin.

REGULAR IMPULSEIdeal for dark skin, dark hair and thick skin damaged by exposure to the sun or through age and for dark, pigmented vascular lesions.

LONG ADAPTIVE IMPULSEFor intermediate skin types, brown hair of medium thickness, vascular/pigmented, average sized lesions.

HIGH ADAPTIVE IMPULSEFor fair skin, light and fine hair, small vascular lesions and benign, light, pigmented lesions.

HR IN MOVING – HAIR REMOVAL ‘IN MOVING’IT’S THE SOLUTION FOR HAIR REMOVAL AT ALL TIMES OF YEAR

The HR IN MOVING handpiece has the function of inhibitingthe growth of hair and fuzz using very fast pulse sequences.This procedure is particularly suitable for treatments on darkand tanned skin. Usable in the summer period.

off

1º imp

60º

35º

tem

pera

ture

time m/s

soglia di sicurezza epidermide

temperaturalesione/pelo

temperaturaepidermide(Solo con guida d’onda in zaffiro fortemente raffreddataa -12 Cº)

2º imp 3º imp 4º imp

off off

Page 6: Medical Platform - Medical Technology

The lasertechnologyof MTONE

ERGONOMIC HANDPIECES AND QUALITY COMPONENTSThese laser handpieces are designed for easy, precise and safe face and body application. The internal components of the handpieces are of the highest quality combined with a superior ‘know how’ conception to improve performance.

VERSATILE COMBINATIONSThe MT-ONE platform can combine Laser and IPL-APC technologies to improve clinical efficiency.

Erbium: YAG 2940nmablative and fractional

Skin resurfacing and Laserpeel (rejuvenation of the face, neck, neckline and hands, light and dark skin types) and in the removal of dermo-epidermal excesses/neoformations dermo (actinic keratosis; Seborrheic warts; seborrheic keratosis, acne).• The MTONE Erbium handpiece has the ABLATIVE

and FRACTIONAL modes on the same handpiece.• Pulse duration: non-thermal to thermal

(400 microsec to 1.5 millisec)• Energy supply with different spot profiles:

9 mm in split mode,3 different ablative tips(2 mm - 4 mm - 9 mm)

Nd: YAG Q-Switched1064 + 532nm

Skin rejuvenation for the treatment of pigmented lesions and *dark tattoos. *Ideal for removing blue and black tattoos – age or sun-related lentigo, face and hands - Nevus of Ota. The 1064 nm Q-switched laser, due to the very short duration of the impulse, limits the damage to the pigment present and carries out a controlled and non-ablative peeling of the surface of the dermis and facilitates its own remodeling.One handpiece for all Qswitched applications with various sizes of spots.• Laser source: Nd: YAG Q-Switched 1064 + 532nm• Pulse energy: 1700mJ @ 1064nm - 1200mJ @ 532nm• Pulse repetition frequency: 1 ÷ 5Hz• Pulse duration: 15ns• Tip with zoom from: 1 to 5 mm• Fixed tip Ø8mm• 532nm frequency duplicator

Erbium: 1540nm non-ablative fractionated GLASS

The fractional laser 1540 provides a rejuvenation treatment free of the complications of ablative treatments. The fractional handpiece emits micro dots of light - microthermal zones (MTZ - microthermal zone) - which penetrate deeply into the skin. The denatured tissue is then replaced by new collagen with consequent improvement of the skin and, in general, of the dermatological pathologies such as atrophic scars, acne scars, surgical scars.Fractional handpiece comprising two tips - 100 and 324 MTZ with sapphire in contact of the fabric that renders the treatment much more comfortable.• Laser source: ErGLASS 1540nm• Pulse energy: 100 MTZ / cm2 from 25 to 70 MJ / MTZ

324 MTZ / cm2 from 6 to 24 MJ / MTZ• Pulse repetition frequency: 1 ÷ 5Hz• Pulse duration: from 10 to 15 ms

Nd: YAG 1064nm LP

Indicated for the treatment of vascular lesions of the body and lower limbs.AngiomasLight and fine hair removalPseudofollicolitis Barbae Treatment (PFB)Spot of 3, 6 and 9 mmPower 30 to 100 JShort-long-burst pulse modeCooling from 0° to -12 °C

DIODE 808

Diode 808nm is the ideal laser for permanent hair reduction. This diode laser can be used during treatments in single shot modes and in the fast mode “IN MOVING”.• Painless• The fastest on the market• Head cooling down to -12 ° C• High energy, 8 microchannel bars

* This type of treatment is not a medical procedure

Page 7: Medical Platform - Medical Technology

SubZeroTechnology

Before /AfterResults

• Double technology Cooling• Guarantees safety, efficacy

and non-pain.The cooling of the tip ranges at 0°C, -6°C, -12°C creates a SUB ZERO effectin the lower layer of the skin.

ADVANTAGE OF EXCLUSIVE TEMPERATURECONTROL SUB ZERO• Eliminates the risk of overdosage

energy• Increased energy output

(most successful)• Cancellation the sensitivity• Patient compliance

Before / AfterAcne - Courtesy Dr. M. Auriemma

Before / AfterDark spots - Courtesy Dr. M. Tretti Clementoni

Before / AfterPort Wine Stain - Courtesy Dr. R. Galvan

Before / AfterRosacea - Courtesy Dr. . Auriemma

Before / AfterRosacea - Courtesy Dr. R. Galvan

Before / AfterAngioma - Courtesy Dr. R. Galvan

SUB ZERO EFFECT

0 °C

32 °F

-12 °C

10.4 °F

Page 8: Medical Platform - Medical Technology

Hair removal

Hair removal

Hair removalIN MOVING

Skin rejuvenation

Vascularand pigmented lesions

PWS Lesions, Telangiectasias

Acne

Skin rejuvenation

Hair removal

Vascular lesionsHair removal

*Tattoo removal. Vascular/Pigmented Lesions

Skin rejuvenation

Electrical Requirements

Dimensions and weight

Interface

110-240V; 50/60 Hz; 1250 VA

600 (W) x 580 (D) x 550 (H) mm3; 59 Kg (without base with wheels)600 (W) x 580 (D) x 1180 (H) mm3; 88 Kg (with base with wheels)

10,1” Colour Touch screen

APC Technology

LASER Technology

HR580

HR630

in moving 630

SR580

LP-LV530LP-LV530 S.M.T.

LP-LV530 S.M.T.

AC420

5-25

5-25

5-8

5-25

5-250.5-25

0.5-25

5-15

up to 95 J/cm2

on Ø 2mm spot

up to 90 J/cm2

30-200 J/cm2

Energy up to 2000 mJ per 1064 nm1600 mJ per 532 nm

100 MTZ/cm2

25 up to 70 mJ/MTZ324 MTZ/cm2

6 up to 24 mJ/MTZ

15-100

15-100

6

10-25

10-250.5-99

0.5-99

15-100

from 0.4 to 1,5

from 1 to 200

from 10 to 100

15 μs

from 10 to 15 ms

6,4

6,4

6,4

6,4

6,4

6,4

6,4

Ømm 2,4,9 ablativeØmm 9 microbeam

1.68 cm2

3 - 6 - 9 mm

from 1 to 8 mm

10 x 10 mm

Er:YAG 2940

Diode 808

Nd:YAG 1064

Nd:YAG Q-S 1064

Er:GLASS 1540

APPLICATION HANDPIECE FLUENCY J/cm3 IMPULSE LENGTH (ms) SPOT SIZE cm2

APPLICATION HANDPIECE FLUENCY J/cm3 IMPULSE LENGTH (ms) SPOT SIZE cm2

Technical Specifications

SALES OFFICEVia degli Olmetti, 18 C700060 Formello (Rome) - ItalyPh. +39 06 [email protected]

PRODUCTIONVia Pietrarubbia, 32F47922 Rimini, ItalyPh. +39 0541 727486

+39 393 [email protected]

medical-technology.it

medical&technology

M&T Medical Technology

mt_medical_technology_rimini

FDA APPROVAL (K192856)

1370

mtone new ita REV. 02

* This type of treatment is not a medical procedure

Page 9: Medical Platform - Medical Technology