Medical Platform - Medical Technology
Transcript of Medical Platform - Medical Technology
Medical Platform
SUB ZERO EFFECT
UPGRADABLETHROUGH TIME
TECHNOLOGYMADE IN ITALY
LASER AND PULSED LIGHTIN THE SAME PLATFORMMTONE is an ALL IN ONE platform,upgradable over time as needed, available with High Power Laserand IPL Handpieces: PULSED LIGHT (over 12 different handpieces) – Laser Diode 808 - Laser Nd: YAG - Laser Erbium: YAG - Erbium Laser:GLASS - Q-Switched Laser.
SUB ZERO EFFECT:UNIQUE TECHNOLOGYMADE IN ITALYA unique and exclusive, contact integrated cooling system of MTONE, consisting of double Peltier technology and water, allowing safe treatmentson dark phototypes and tanned skin.Up to -12° C.
APC ADVANCED PULSEDLIGHT TECHNOLOGYA unique method of energy supply,by controlling impulses of pulsed light. Work can be performed in single and burst mode.
HIGH QUALITYCOMPONENTSthe optical and electronic components of the platform and handpieces are of the highest level of quality. The size and appearance of the handpieces are larger than that of others on the market.
Advanced graphical interface with automatic, semi automatic and manual treatment parameter control
REMOTE SERVICEOnline technical assistance from the studio to production site
• Automatic handpiece and treatmentparameter recognition
• Capacitive touch screen displayof 10.1 inches
• Advanced graphical user interfacewith manual, automatic andsemi-automatic treatment parametercontrol
• Quick connect hot swap handpieces• Automatic handpiece detection
and treatment parameters• Compact trolley with optional
container
All In OneScalableCompact
630-950 nm
580-950nm
530-950nm
530-950nm S.M.T.
420-950nm
808nm
2940nm Er:YAG
1064 nm Nd:YAG
Er:GLASS 1540 nm
Nd:YAGQSWITCHED1064+532 nm
IPL
IPL
IPL
IPL
IPL
Laser
Laser
Laser
Laser
Laser
SOURCEANDWAVELENGTH
HANDPIECE SUGGESTIONS
Permanent hair removal and reduction, all skin types (I-VI) on the Fitzpatrick Scale
Permanent hair removal and reduction, all skin types (I-VI) on the Fitzpatrick scale. In addition, treatment of benign Pigmented Lesions and skin lesions, including scars, stretch marks
Pigmented and vascular lesion treatment, all skin types (I-VI) on the Fitzpatrick Scale
Pigmented and Vascular Lesions Treatment, all skin types (I-VI) on the Fitzpatrick scale. Vascular / PWS lesions, telangiectasias.
Acne vulgaris treatment - all skin types (I-VI) on the Fitzpatrick scale
Permanent hair removal for face and body. Treatment of benign vascular and pigmented lesions
Suitable for use in soft tissues and skin tissue: Skin ResurfacingNeviTelangectasiaSpider veinsActinic keratosesKeloidsKeratosisAcne scars
Treatment of vascular lesions of the body and lower limbs, angiomas, light and fine hair removal, Pseudofollicolitis Barbae Treatment (PFB)
Acne scars, post-surgical or post-traumatic scars, (facial wrinkles)
Pigmented and vascular lesion treatment, skin rejuvenation, *dark tattoo treatment
Whyit’s different:All In One
ForAll SkinType
* This type of treatment is not a medical procedure
Pulsed light with “APC” technology
APCExtremely effectiveand safe
APC - ADAPTIVE PULSE CONTROLis a unique technology of MT ONE, capable of providing energy homogeneously over the entire duration of the impulse.
Thus, energy peaks are avoided, which are particularly dangerous for the treatment of dark skin. APC has an impulse control of pulsed light for an automatic selection of the best treatment configuration.
APC operates in two ways, single or burst (pulse train), for better efficiency and safety. This function adjusts the correct sequence of pulses together with the energy needed for safe treatment.
APC - with different pulse and wavelength configurations,combined with the powerful contact cooling system and the pure sapphire wave guide, is able to perform comfortable and effective treatmentsfor all skin types.
AC 420
VL-PL 530
SMTSub MillisecondTechnology
HR 580
LP-LV 530
HR 630
SR 580
HR IN MOVING
MTONE has several pulse andwave configurations, combinedwith the powerful contact skincooling system and the wave guidein sapphire - SUB ZERO EFFECT - is able to perform comfortable and effective treatments for all skin typesand conditions.
Peltier thermoelectric cooling, together with the precision of the sapphire optical filter and the exclusive APC (Adaptive Pulse Control) ensure safe treatments and optimal results.
The different handpieces with a wide range of wavelengths for each treatment, thanks to the SUB ZERO EFFECT, is able to maintain a very low skin temperature even during“IN MOVING” procedures.
MTONE with IPL handpieces has three different pulse configurations for the emission of energy, in order to adapt perfectly to the needs of all difficult treatment conditions, such as thinhair or dark skin.
REGULAR IMPULSEIdeal for dark skin, dark hair and thick skin damaged by exposure to the sun or through age and for dark, pigmented vascular lesions.
LONG ADAPTIVE IMPULSEFor intermediate skin types, brown hair of medium thickness, vascular/pigmented, average sized lesions.
HIGH ADAPTIVE IMPULSEFor fair skin, light and fine hair, small vascular lesions and benign, light, pigmented lesions.
HR IN MOVING – HAIR REMOVAL ‘IN MOVING’IT’S THE SOLUTION FOR HAIR REMOVAL AT ALL TIMES OF YEAR
The HR IN MOVING handpiece has the function of inhibitingthe growth of hair and fuzz using very fast pulse sequences.This procedure is particularly suitable for treatments on darkand tanned skin. Usable in the summer period.
off
1º imp
60º
35º
tem
pera
ture
time m/s
soglia di sicurezza epidermide
temperaturalesione/pelo
temperaturaepidermide(Solo con guida d’onda in zaffiro fortemente raffreddataa -12 Cº)
2º imp 3º imp 4º imp
off off
The lasertechnologyof MTONE
ERGONOMIC HANDPIECES AND QUALITY COMPONENTSThese laser handpieces are designed for easy, precise and safe face and body application. The internal components of the handpieces are of the highest quality combined with a superior ‘know how’ conception to improve performance.
VERSATILE COMBINATIONSThe MT-ONE platform can combine Laser and IPL-APC technologies to improve clinical efficiency.
Erbium: YAG 2940nmablative and fractional
Skin resurfacing and Laserpeel (rejuvenation of the face, neck, neckline and hands, light and dark skin types) and in the removal of dermo-epidermal excesses/neoformations dermo (actinic keratosis; Seborrheic warts; seborrheic keratosis, acne).• The MTONE Erbium handpiece has the ABLATIVE
and FRACTIONAL modes on the same handpiece.• Pulse duration: non-thermal to thermal
(400 microsec to 1.5 millisec)• Energy supply with different spot profiles:
9 mm in split mode,3 different ablative tips(2 mm - 4 mm - 9 mm)
Nd: YAG Q-Switched1064 + 532nm
Skin rejuvenation for the treatment of pigmented lesions and *dark tattoos. *Ideal for removing blue and black tattoos – age or sun-related lentigo, face and hands - Nevus of Ota. The 1064 nm Q-switched laser, due to the very short duration of the impulse, limits the damage to the pigment present and carries out a controlled and non-ablative peeling of the surface of the dermis and facilitates its own remodeling.One handpiece for all Qswitched applications with various sizes of spots.• Laser source: Nd: YAG Q-Switched 1064 + 532nm• Pulse energy: 1700mJ @ 1064nm - 1200mJ @ 532nm• Pulse repetition frequency: 1 ÷ 5Hz• Pulse duration: 15ns• Tip with zoom from: 1 to 5 mm• Fixed tip Ø8mm• 532nm frequency duplicator
Erbium: 1540nm non-ablative fractionated GLASS
The fractional laser 1540 provides a rejuvenation treatment free of the complications of ablative treatments. The fractional handpiece emits micro dots of light - microthermal zones (MTZ - microthermal zone) - which penetrate deeply into the skin. The denatured tissue is then replaced by new collagen with consequent improvement of the skin and, in general, of the dermatological pathologies such as atrophic scars, acne scars, surgical scars.Fractional handpiece comprising two tips - 100 and 324 MTZ with sapphire in contact of the fabric that renders the treatment much more comfortable.• Laser source: ErGLASS 1540nm• Pulse energy: 100 MTZ / cm2 from 25 to 70 MJ / MTZ
324 MTZ / cm2 from 6 to 24 MJ / MTZ• Pulse repetition frequency: 1 ÷ 5Hz• Pulse duration: from 10 to 15 ms
Nd: YAG 1064nm LP
Indicated for the treatment of vascular lesions of the body and lower limbs.AngiomasLight and fine hair removalPseudofollicolitis Barbae Treatment (PFB)Spot of 3, 6 and 9 mmPower 30 to 100 JShort-long-burst pulse modeCooling from 0° to -12 °C
DIODE 808
Diode 808nm is the ideal laser for permanent hair reduction. This diode laser can be used during treatments in single shot modes and in the fast mode “IN MOVING”.• Painless• The fastest on the market• Head cooling down to -12 ° C• High energy, 8 microchannel bars
* This type of treatment is not a medical procedure
SubZeroTechnology
Before /AfterResults
• Double technology Cooling• Guarantees safety, efficacy
and non-pain.The cooling of the tip ranges at 0°C, -6°C, -12°C creates a SUB ZERO effectin the lower layer of the skin.
ADVANTAGE OF EXCLUSIVE TEMPERATURECONTROL SUB ZERO• Eliminates the risk of overdosage
energy• Increased energy output
(most successful)• Cancellation the sensitivity• Patient compliance
Before / AfterAcne - Courtesy Dr. M. Auriemma
Before / AfterDark spots - Courtesy Dr. M. Tretti Clementoni
Before / AfterPort Wine Stain - Courtesy Dr. R. Galvan
Before / AfterRosacea - Courtesy Dr. . Auriemma
Before / AfterRosacea - Courtesy Dr. R. Galvan
Before / AfterAngioma - Courtesy Dr. R. Galvan
SUB ZERO EFFECT
0 °C
32 °F
-12 °C
10.4 °F
Hair removal
Hair removal
Hair removalIN MOVING
Skin rejuvenation
Vascularand pigmented lesions
PWS Lesions, Telangiectasias
Acne
Skin rejuvenation
Hair removal
Vascular lesionsHair removal
*Tattoo removal. Vascular/Pigmented Lesions
Skin rejuvenation
Electrical Requirements
Dimensions and weight
Interface
110-240V; 50/60 Hz; 1250 VA
600 (W) x 580 (D) x 550 (H) mm3; 59 Kg (without base with wheels)600 (W) x 580 (D) x 1180 (H) mm3; 88 Kg (with base with wheels)
10,1” Colour Touch screen
APC Technology
LASER Technology
HR580
HR630
in moving 630
SR580
LP-LV530LP-LV530 S.M.T.
LP-LV530 S.M.T.
AC420
5-25
5-25
5-8
5-25
5-250.5-25
0.5-25
5-15
up to 95 J/cm2
on Ø 2mm spot
up to 90 J/cm2
30-200 J/cm2
Energy up to 2000 mJ per 1064 nm1600 mJ per 532 nm
100 MTZ/cm2
25 up to 70 mJ/MTZ324 MTZ/cm2
6 up to 24 mJ/MTZ
15-100
15-100
6
10-25
10-250.5-99
0.5-99
15-100
from 0.4 to 1,5
from 1 to 200
from 10 to 100
15 μs
from 10 to 15 ms
6,4
6,4
6,4
6,4
6,4
6,4
6,4
Ømm 2,4,9 ablativeØmm 9 microbeam
1.68 cm2
3 - 6 - 9 mm
from 1 to 8 mm
10 x 10 mm
Er:YAG 2940
Diode 808
Nd:YAG 1064
Nd:YAG Q-S 1064
Er:GLASS 1540
APPLICATION HANDPIECE FLUENCY J/cm3 IMPULSE LENGTH (ms) SPOT SIZE cm2
APPLICATION HANDPIECE FLUENCY J/cm3 IMPULSE LENGTH (ms) SPOT SIZE cm2
Technical Specifications
SALES OFFICEVia degli Olmetti, 18 C700060 Formello (Rome) - ItalyPh. +39 06 [email protected]
PRODUCTIONVia Pietrarubbia, 32F47922 Rimini, ItalyPh. +39 0541 727486
+39 393 [email protected]
medical-technology.it
medical&technology
M&T Medical Technology
mt_medical_technology_rimini
FDA APPROVAL (K192856)
1370
mtone new ita REV. 02
* This type of treatment is not a medical procedure