Medalist i3070 08.30p software release
-
Upload
interlatin -
Category
Technology
-
view
1.991 -
download
30
Transcript of Medalist i3070 08.30p software release
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Medalist i3070 08.30p
Software Release
Page 1 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
3. How to get 08.30p?
Page 2 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
• Software Release Milestone
• Change Request List
2. What’s new in 08.30p?
3. How to get 08.30p?
Page 3 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Current Product Engineering (CPE)
08.10p
SW
Continuous Improvement & Innovations
i3070
and
i3070
S5
2009 2010
08.00p SW
Utility Cards
& ASRU N
2011
July 2012 Page 4
Medalist i3070 Software Release Milestone
Jul
2012
Oct
Agilent LED TestAug
08.20p
SW
08.30p SW
(XP & Win7)
Win 7Nov
08.40p SW
(XP & Win7)
April*
New Features 08.20p 08.21p 08.30p
High-Power (N5747) Power Supply
High Voltage Zener
Windows 7 (32 bits)
Windows 7 (64 bits*)
LED Test
External DLL call
rp5800 PC
* Subject to change
08.21p
(XP & Win7)
NovFeb
2013
Aug
135 Change Request
Ship - 1 Aug 2012.
Field distribution - 1 Aug 2012
SUS distribution - 17 Sep 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
July 2012 Page 6
Appendix: Change Request List - 1
CR ID TitleCR27877 Unable to compile analog cluster (magic test) at PBD
CR29362 07.00pf: Board Consultant: Range for Tolerance Multiplier Is IncorrectCR33453 i3070 : ERROR!! result from Browser Locator Find Probe action
CR33602i3070: Controllerloop causes measurement timeout in analog portion of mixed test
CR33604i3070SW: Panel testplan subroutine Program_Flash does not declare variables True
CR3384208.10: Support Info-Readme Under Control Panel For Agilent IO 15.5 not working
CR33922 08.10: CA: Tested in parallel incorrect coverage countCR33962 Digital setup editor would shutdown CR33990 customer requests an ability to call DLL command libraries CR34045 08.20:Engineer GUI, More then one "GL" boxes can be checked
CR34048 program memory exceeded
CR34080 08.20 DGN Display Failure issueCR34085 08.20 : Browser : Personality Pins cannot browseCR34090 parse board and board_xy for conflicts when loading in operator GUICR34099 Get statement automatically writes name in the title bar of BT-BasicCR34100 Automated display backslashes as slashes in BT-Basic Title
CR34111 preferences setting in the board directory and User home directory CR34116 To enable ASRU N to work under UNIX as ASRU C / D
CR34119 Should auto check "En" option if sense "A" is used CR34126 08:20 Agilent Coverage Analyst got wrong RevisionCR34127 08.20: TTFXT_HP6621 compile config failed
CR3413308.20: Engineer GUI : Incorrect message for ar value of less than 18 for HVZ
CR34136symlink & iNode not working in TTDB GUI Panel test strategy when using NFS
CR3413908.20p: HVZ_TTDB mark permanent or commented cause prepowerederase in testorder
CR34142 digital test reports error from AUX which is not used
CR ID TitleCR34143 quick report doesn't find all testsCR34150 ASRU N diagnostics failure 2824CR34152 08.20a: Support Info closes automaticallyCR34154 Alternate PC portable based dongle pin card programmingCR34156 To remove MIL-STD-45662A wording from NIST CAL testplan CR34159 08.20p "load board" command takes longer time to finishCR34162 3070SW: icap card: fixture auto- unlocked during reboot.CR34163 Add lost heart beat message and time stamp in pmlog
CR34165Data polling in flash isp test does not work with xtp firmware version 10071517
CR34166 enhance ASRU cal 4395 and 4396 to write and check tracking featureCR34167 i3070: Enh Req to inhibit auto-converting to Multiple Board Versions
CR34170i3070 8.20p: need to select FPY/WPR view each time Operator GUI is launched
CR34175DC capacitor test causing subsequent test with "ed" option failed or timeout
CR34177 NPM Issue encounterred in 08.20pCR34179 08.20: ASRU N Diagnostic Failure T2824 - Improve yieldCR34180 08.20p: Wrong Error message for ASRU CalibrationCR34181 Pushbutton Debug Window closes when Marking a Test as permanent.
CR3418208.20b: By default, FPY and WPR should be tick check after operator GUI start
CR34183 08.20b: No revision info display in i3070 Medalist
CR3418508.20b: Installed Window Service for Unix cause issue in control of testhead
CR3419008.20: CA: BScan,CE and SN not reported as Test Technique used in Executive Sum
CR34191 Coverage Analyst not handling Preshorts and Powered Analog correctly
CR34192NIST Calibration Testplan uses Wrong Units for Temperature in Report Header
CR34200 i3070 8.x: BT-Basic Internal Error -13 at 'select boards on panel'
CR34204Relay Locator Diagram for unmux hybrid shows incorrect reference designators
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Appendix: Change Request List - 2
July 2012 Page 7
CR ID Title
CR34208 Xvision Install error if i3070 sw is removed and re-installed 0820p
CR3420908.20p: BSDL parser does not flag single-ended, differential pins as errors
CR34214 4 Languages Software License Term
CR34215Making Diagnose Relay licensing requirement same for Mux and Unmux
CR342163070: The BSDL compiler does not issue a warning for part 4 of rule B.8.18.4u).
CR34218 08.30: Default xtp.xsvf file is 02020812_1 instead of 11060116_1
CR3421908.30: Installation: Missing link (file) to Medalist i3070 software install help
CR3422008.30: DGN new Test 8 (cal date & stored data) implemented on Unmux
CR34221 08.30 : DGN : Request to identify module # for T4396
CR3422308.30 : Expired cal: Calibration Message for testh is 1 is incorrect & clearable
CR34224 08.30:No Program_pin_card lic "Program Cards" is still enabled in DGN
CR34227 i3070: ENH REQ Board Consultant should display more than 5 boards
CR34228i3070 8.x: ENH REQ board setting for IPG to write AC cap test or DC cap test
CR34229i3070: ENH REQ FXT53 WARNING message much obvious for insufficient access
CR34230 08.20: Hang on xvision uninstallation of 08.20p
CR34231 With rev 0820p it's not possible to open Setup Editor
CR34236 i3070 8.x: Conversion Tool needs updating for 8.x software
CR3423708.30:Oper GUI: Implement saved setting to show/hide FPY/WPR on Chinese locale
CR34239 i3070 08.xx: Improve file checking efficience over network
CR34240 I3070HW: Nasru Cards are reporting 3374/3376 Errors.
CR34248Testplan statements itb$ and num cause missing characters on display and in logs
CR ID Title
CR34249Mixed Test failing line numbers and calling sequence not displayed in PBDebug
CR34252 i3070 8.00p: Unility Card mux power supply wiring failed
CR3425408.20: CA: Panel : Wrong report:tested devices reported as untested & vice versa
CR34258 i3070: ConnectCheck learned value not save in PBDebugCR34259 08.20e: PBD : Internal Error -11 opening a digital test
CR3426008.20e:UnMUX:T342 Control 3 Real Math Error running the Analog_Tests subroutine
CR3426208.20pe: Angela board; Bt Basic encounter internal error when call Analog_Test
CR34263 i3070: Actel STAPL not compatible with 3070 PLD ISPCR34265 extra line of 'sequencer halted' in digital failure messageCR34266 08.20e : vcllib.exe error during lib compileCR34268 IPG select inaccessible nodes in .discharge testCR34269 i3070: ICT Browser and Engineer GUI "Error in File Type: board"CR34270 breaking recycle to fail for polarity test causes Pascal system error 8
CR34271 Display Graphics menu is grey out for Polarity test in Pushbutton debugCR34276 08.30 Uninstall, SCO Vision hang during uninstallCR34277 08.30p Engineer Gui AIC Left Table duplicate column for CPKCR34278 08.30p Installation,AgilentIO encounter error 1722 if use fresh WinXP HDCR34279 Need the maximum Instruction Register length to be increasedCR34281 08.30p Engineer GUI - Missing Permanent column in AIC Left Table
CR3428208.30p Testh power off - Failure in Medalist operator gui and Btbasic window
CR34288 08.30 BtBasic, GPIB timeout when do 'testhead is 1'CR34290 Coverage Analyst hangs at Binding Test and Board Data
CR3429108.30 Wrong Control XTP seq FPGA version, expected version is 11060116_1
CR34292 3070 GUI hangup on 2lvl fn calls
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
July 2012 Page 8
Appendix: Change Request List - 3
CR ID TitleCR34293 Stapl compiler does not parse arithmetic assignment properlyCR34294 N6751A DUT power supply fail DGN Test number 2340-DPS ground faultCR34295 08.30: Program Asru encounter software internal error
CR34297 8.30p IPG Test Consultant GUI -Selected Directory Contents issueCR34301 Timer functions to capture test time at board or sub-test level CR34305 Needs auxconnect that does not release when press STOP CR34306 Histogram failed to generate on failing tests (i3070 Medalist)CR34308 Quick Report does not report new hardwareCR34311 Enable back ps6751 CR34312 Control XTP Psync ErrorCR34318 Browser cannot display a panelized board in Bank 1CR34319 08.30: Cannot launch BScan Chain ViewerCR34321 08:30: Testhead cannot boot successfully in RP5800 controllerCR34322 Incorrect .discharge file causes relay damage
CR34323debug end causes bt-basic hang when digital waveform window is the 4th window
CR34324 08.30: Operator GUI :SpecialAux --> Set : File or directory not found CR34325 08.30: Special Aux connect feature implementation
CR34326 08.20: add support for boundary-scan 1149.8.1 standard in ballot
CR3432708.20: Unconnected test receiver does not capture data for differential pairs
CR34328Allow CET for panel board with even no. of boards when CET Gnd wired to XTP Gnd
CR ID Title
CR34329 Recommend new kind of wiring for CET Card to prevent CET burnoutCR34330 Support uVTEP with license controlCR34334 08.30: Outdated Agilent copyright year info CR34336 08.30: ASRU N Diagnostic Failure T2283 - Improve yieldCR34337 Enhanced 6M 12M hybrid mixable in testhead
CR34338 08.30: To add an error variable parameter for external dll commands
CR3433908.30p IPG TestConsultant - Run Test Cell Manager window caption wrong
CR34340 08.30p BtBasic caption missing "\"CR34346 Boolean array assignment and syntax error line number displayCR34348 08.30: Q-Stats report Histogram type encounter hang
CR34349 08.30: PBD_Edit menu execute Copy and Paste failed and cause GUI hang
CR34350 08.30: PPU_without credit button still can load board and run ICT test
CR34357 08.30p - Installation microsoft .net 3.5 maintenance mode screenCR34358 08.30: Unable to execute A3070toI5000.pl successfully
CR34359 08.30: PBD_after autodebug NPM execute to fail have internal error -11CR34360 TCM Account Starts in Program Monitor ModeCR34364 HVZ test is generated for ASRU-C configCR34365 08.30: PPU_Widget bar "stop" not functionCR34366 08.30: Compile error of Actel STAPL file
CR34384Improve IPG discharge with more conservative calculations for .discharge file
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
• Capability and Functionality:
• Technology Upgrade:
• Productivity Enhancement:
• Licenses enable features:
3. How to get 08.30p?
Page 9 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
1. BT-Basic DLL integration feature Overview
Page 10 July 2012
i3070 DLLs
Functional
Test
Production
Mgmt SW
Flash Prog
Commands & Syntax Example:
dllload “<dll-name>”, <dll-handle> dllload “getboard_data.dll”, Handle_1
dllcall <dll-handle>, “<custom function name>”, [<return
number>], [“<return string>”]; [“<custom parameters>”]
dllcall Handle_1, “blank_check”,
Var_1, ErrMsg$; “0, 0xffff”
dllunload [<dll-handle>] dllunload Handle_1
Ext_App_DLL feature license is needed to enable and
execute the following three new commands:
Wrapper DLL is needed to export the standard APIs BTBasic_DLL_Call() for BT-Basic to call, and
redirects the call to 3rd party software
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Programming Model Overview
Generic flow of BTBasic executing dllcall, through the DLL wrapper to the DLL functions:
Page 11 July 2012
BT-Basic
dllload(“UtilWrapper.dll”, Handle_1)
…
dllcall Handle_1, “DoSimFun1”,
Var_1, ErrMsg$; “100”
…
Calls
DLL wrapperB
BTBasic_DLL_Call(“DoSimfunc1”,
“100”, ErrMsg,
Var_1)
DoFun1(int nCount)
{ // perform some algorithm }
Calls
Customer’s DLLs
BT-Basic
…dllcall Handle_1, “blank_check”,
Var_1, ErrMsg$; “0, 0xffff”
…
DLL wrapperA
BTBasic_DLL_Call(“blank_check”, “0,
0xffff”, ErrMsg, Var_1)
Func DLL
blank_check(0, 0xffff)Calls Calls
Customer’s DLLs
1.
2.
3.BT-Basic
dllload(“UtilWrapper.dll”,
Handle_1)
…
dllcall Handle_1, “DoSimFun1”,
Var_1, ErrMsg$; “100”
…
dllcall Handle_1, “ExDllFunc1”,
Var_1, ErrMsg$; “0,
0xffff”
dllunload(Handle_1)
Calls
UtilDLL
ExDllFunc1(0,
0xffff)
DLL wrapperC
BTBasic_DLL_Call(“DoSimfunc
1”, “100”,
ErrMsg, Var_1)
DoFun1(int nCount)
{
// perform some algorithm}
…
BTBasic_DLL_Call(“ExDllFunc
1”, “0, 0xffff””,
ErrMsg, Var_1)
Calls
Customer’s DLLs
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
External DLL call (Sample)
Page 12 July 2012
Example:
- Custom function Sum() in the Sample.DLL
- In BT-Basic, enter dllcall Dll-handle “Sum”, RetrunNum,
ReturnString$; “10,20,30”
- BT-Basic will call the function BTBasic_DLL_Call() with
functionName “Sum” and parameters “10,20,30”.
- The parameters string “10,20,30” is converted into integer
array and passed to function Sum().
- The Sum() calculate the sum of the elements of the integer
array, and return back the result to caller.
- The value of ReturnNum will be 60 and the content of
ReturnString$ will be "Function \"Sum\" has been called!"
Specification:
1. User Wrapper DLL – Must be C++
2. Ext_App_DLL feature license needed during runtime
Default:
• example:
dllload “Demo.dll”, Handle
Then, Software search the DLL at
Agilent_ICT\ext_dev
User specify full path
• example:
dllload
“Agilent_ICT\boards\demo\Demo.dll”,
Handle
Then, software search the DLL at
Agilent_ICT\boards\demo
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
BT Basic - External DLL (Demonstration)
Page 13 July 2012
1. Demo.dll – updating Pass/Fail status of
the DUT to the “demo.mdb” database.
2. The testplan_demo is updating test
status for board with SN „0001‟ and
‟0002‟ .
3. Initial test status in database, „0001‟
and „0002‟ are passed.
4. Assumed „0001‟ Pass and „0002‟ Fail.
5. Getting the status of S/N 0001 from
database and update the result .
6. Getting the status of S/N 0002 and
update accordingly.
7. SN0002 updated as FAIL.
8. Finally, the testplan unload the DLL
from memory.
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
July 2012 Page 14
2. Agilent i3070 LED Test solution
Cost effective LED test at ICT.
An industry FIRST! An Agilent innovation using proprietary architecture to
measure LEDs with blazing speed – fastest in the industry.
Accurate and repeatable color and intensity measurements ensures
consistently reliable results.
Fastest analysis speed saves time and money.
Highest signal-to-noise performance enables you to test the widest range of
LEDs.
ORi3070 LED Test Box i3070 LED Test Card
N1
80
7A
Uti
lity
Car
d
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
July 2012 Page 15
Agilent i3070 LED Test solution
Fast, accurate, flexible and repeatable.
• Proprietary architecture will send digital stimuli, measure the LEDs‟ color and
intensity and returning results of up to 128 LEDs in less than 1.3 seconds.
• Acquires the peak, base or instantaneous wavelengths of the LED color and
returning the measurement in nanometers (nm).
• Measures the LED intensity(luminosity) in μW`/cm2
• Uncompromising repeatability achieved through a shroud tube design to shield
noise (ambient light) from surrounding LEDs.
Throughput
Up to 128 LED sensors in 1.3s
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
July 2012 Page 16
Agilent i3070 LED Test solution
Release 8.3
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
• Capability and Functionality:
• Technology Upgrade:
• Productivity Enhancement:
• Licenses enable features:
3. How to get 08.30p?
Page 17 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
1. RP5800 PC
Page 18 July 2012
Rp5700 RP5800
Operating
System
Microsoft Vista32B
Downgrade to XP32B OS
or
Windows 7 Pro 32B
Microsoft Windows 7 Pro
32B
Processor
Intel® Dual-Core
Processor E2160 (1.80
GHz, 1 MB L2 cache,
800 MHz FSB)
Intel® Core™ i5-2400
(3.10 GHz, 6 MB cache,
4 cores)
Memory
HP 2GB PC2-5300
(DDR2-667) Memory - 4
DIMM Slot
4GB PC3-1333MHz
DDR3 SDRAM (Max
16GB)
GraphicIntegrated Intel Graphics
Media Accelerator 3000
Integrated Intel HD
Hard Drive 160GB SATA 3.0GB/s250GB
SATA (7200 rpm)
DVD 16X SATA DVD-WriterSATA SuperMulti DVD
writer
NetworkBroadcom NetXtreme
Gigabit PCI-E Adapter
Integrated Intel
82579LM
Intel PRO 1000 CT GbE
(optional)
Ports2 Rs232 ; 6 USB ; 1
parallel
7 USB 2.0
1 24V powered USB
2 RS-232
Part number Description
0960-3030 rp5800 with Windows 7 OS without
ICT Software
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
rp5800 Vs rp5700 Test Time
Page 19 July 2012
Windows 7 Rp5700 rp5800
Test Type sec secPreshorts 0.248 0.269Shorts 0.250 0.246
Unpowered Analog 0.251 0.248
Vectorless Test 0.467 0.465
Polarity Test 0.127 0.141
PS Setup 0.447 0.454
BScan Powered Shorts 25.133 25.134
BScan Interconnect 0.193 0.198
BScan Incircuit 4.871 4.879
Bscan Silicon Nails 0.033 0.044
Cover Extend 0.598 0.409
Flash ID 0.017 0.015
Flash Erase 10.044 10.043
Flash Blank 0.018 0.018
Flash Program 0.048 0.046
Flash Verify 0.040 0.038
Flash CRC 0.162 0.161
CPLD 6.338 6.335
Total Digital Test 16.793 16.783
Analog Functional (Mixed) 0.053 0.055
Total Test Time 66.131 65.981
LOAD BOARD Time
(Across Network)
LAN Card Setting
RP5700 (08.21p)
RP5800(08.21p)
Auto (100M)
4.2086 sec 2.75625 sec
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
2. Installing Medalist i3070 08.30p
Page 20 July 2012
Windows 7 32-bit and Windows XP 32-bit OS
• Available for Testhead and Test Development Workstation
Windows 7 64-bit OS
• Available for Test Development Workstation
Windows XP OS
• Prompt to update Third Party Software to1. Nutcracker 9.4
2. Xvision 731/MKS X Server
3. Agilent IO 16.1
4. ScanWorks 3.14
5. Bootp Turbo
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
• Capability and Functionality:
• Technology Upgrade:
• Productivity Enhancement:
• Licenses enable features:
3. How to get 08.30p?
Page 21 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
1. Special AUX Connect
A new set of BT-Basic special aux commands:-
run, stop, abort, start, and wait for start
Page 22 July 2012
• declares relay 5 to be a special relayspecial aux set 5
• closes the relayspecial auxconnect 5
• opens the relay special auxdisconnect 5
• Clear mappingspecial aux clear 5
- Cannot be controlled with the auxconnect and auxdisconnect commands
- Error occurs if
Not yet declares as special
Close or Open the relays that mapping has clear
Specified as vacuum ports in the testhead config file.
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
2. Global setting for Large Capacitor
Page 23 July 2012
New Global option to allows IPG to write DC mode capacitor
To use it; insert Large Capacitor DC Mode On or Off in board file.
Global Option in Board File Capacitance IPG will generate:
Not specified >= 1000 uF AC mode capacitor test
Large Capacitor DC Mode On >= 1000 uF DC mode capacitor test
Large Capacitor DC Mode Off >= 1000 uF AC mode capacitor test
Not specified < 1000 uF AC mode capacitor test
Large Capacitor DC Mode On < 1000 uF AC mode capacitor test
Large Capacitor DC Mode Off < 1000 uF AC mode capacitor test
Can enable through Board Consultant.
Backward compatibility
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
3. Discharge algorithm Enhancement
Page 24 July 2012
Software Rev Enhancement Remark
08.20p Entry Voltage <= 2v for discharge
08.30p Improve IPG discharge with more
conservative calculations for
.discharge file
APG_DISCHARGE_ROBUST = False
(conservative) – Default for 08.30p and later
APG_DISCHARGE_ROBUST = True (actual)
For 08.20p or earlier
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
4. CET New Wiring Recommendation
Page 25 July 2012
VTEP Mux cable
CET USB cable
(with ferrite coil)
CET LEM_A,R,M &
Power
VTEP Mux card
CET card
1
220
19
CET Power
Data +
USB GND
USB VCC
Data -
LEM_ALEM_R
LEM_M
CET GND
HYBRID GND
1
220
19
CET Power
Data +
USB GND
USB VCC
Data -
LEM_ALEM_R
LEM_M
CET GND
Old Wiring New Wiring
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
5. Others Important Changes
• Unmux – Relay diagnostics license replaced by Advanced DGN
• Load Board time has been improved.
• Solved “Pushbutton Debug Window closes when Marking a Test as permanent”.
• IPG no longer select inaccessible nodes in .discharge test.
• FXT53 WARNING message for insufficient access is more visible.
• STAPL compiler (JDEC standard) is enhanced to support Actel devices. (example: CPLD devices)
Page 26 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
• Capability and Functionality:
• Technology Upgrade:
• Productivity Enhancement:
• Licenses enable features:
3. How to get 08.30p?
Page 27 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
1. Mixed Hybrid 6 MPs and 12 MPs
Example 1 Example 2 Example 3 Example 4
LicensePower-Test Upgrade
Hybrid Std Adv Mix
12M Modifier
20M Modifier
Hybrid Std Adv Mix
12M Modifier
20M Modifier
Hybrid Std Adv Mix
12M Modifier
20M Modifier
Hybrid Std Adv Mix
Actual Hardware Hybrid Standard
Hybrid Advanced
Hybrid Standard
Hybrid Advanced
Hybrid Standard
Hybrid AdvancedHybrid Advanced
System config fileChange to match
actual hardware
Change to match
actual hardware
Change to match
actual hardwareNo changes
Board config Hybrid Standard Hybrid Standard Hybrid Advanced Hybrid Advanced
Test Board? Yes Yes Fail Load board. Yes
Page 28 July 2012
Expectation & Condition:1. Is Not standard offering; for installed
based customer that has challenge in
asset management.
2. BDM approval needed for temp license on
case by case basis
3. Use model not listed in User Online Docs
4. Follows slowest cards if detected
5. No impact to Autoadjust and DGN tests
License enable feature
Allow Hybrid 6MPs and 12MPs (only)
to be mixed in the system.
Available on 08.30p or later
Time based license only
(Hybrid_std_adv_mix feature)
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
BT-Basic commands to enable the
ASRU N card to function as Rev “C” in
Unix or Rev “N” in Windows
Available on 08.30p or later
Time based license only
Unix
Controller
Page 29 July 2012
2. Enable ASRU N as ASRU C for Unix
Condition & Expectation:1. Is Not standard offering; is targeted for
Dual Boot environment
2. BDM approval needed for temp license on
case by case basis
3. DGN failures expected in Rev “C”. No fix is
required.
4. No software support in Rev “C” (Unix)
5. Use model not listed in User Online Docs
6. NIST/ASRU cal must be done in ASRU Rev
“N”. No support for Rev “C”.
7. No issue for Autoadjust in Rev “C”
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
BT-Basic Command
Page 30 July 2012
Output:
0 0-0 1-0 2-C 3-C
asru state - 0/C/N. 0 means No cardModule No. 0 – 3.
Command result. 0-successful, non-zero–Failed
Command Example:
program asru c/n, State$, Error program asru c, Rtn$, Err
program asru c/n, State$, Error; option program asru c, Rtn$, Err; noboot
Example of subroutine:
Error = 0 | State$ ="NoState“
program asru c, State$, Error; noboot
testhead is 1, Err
if Error <> 0 then
testhead power on
end if
fixture lock
Note: State$ and Error variable position non-swappable
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
ASRU N in Rev “C” mode - DGN Test results
ASRU-N as ASRU-C DGN results (No fix is required)
Page 31 July 2012
Test# Descriptions Reason
T2346 Source Output Resistors and MOA Feedback Resistors. transformer circuitry removed in ASRU-N
T2711 Interconnect MUX Relays K801, K802, K803 and K804 removed in ASRU-N
T2713 Interconnect MUX Relays K809, K810 and K817 removed in ASRU-N
T2720 SUBMUX S-bus Relays Closed Changed test source voltage to 0.05V from 0.1V for
ASRU-N 2-ounce copper layout
T2722 SUBMUX I-bus Relays Closed Changed test source voltage to 0.05V from 0.1V for
ASRU-N 2-ounce copper layout
T2724 SUBMUX L-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for
ASRU-N 2-ounce copper layout
T2726 SUBMUX A-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for
ASRU-N 2-ounce copper layout
T2728 SUBMUX B-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for
ASRU-N 2-ounce copper layout
T2091 SRC dc accuracy lo/hi current mode unloaded(-10 V) Marginal failure
T2311 K854, K855 open relay tests Marginal failure
T2312 K748, K761 open relay test Marginal failure
T2314 K747 + K760 close relay test transformer circuitry removed in ASRU-N
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
3. Control XTP firmware
Page 32 July 2012
1. New Control XTP firmware version 11110111_1.xsvf as a backup file.
2. To solve “T313 Control card timeout waiting for Psync signal error” that
encountered on some Control XTP cards with NEC 2Mx8bit SRAM.
3. No change is needed if you didn’t encounter the Psync issue with the
existing xtp.xsvf (110601116_1.xsvf).
To use Control XTP firmware version 11110111_1:
1. Locate the file C:\Agilent_ICT\lib\xtp.xsvf and rename it
as 110601116_1.xsvf.
2. Locate the file C:\Agilent_ICT\lib\11110111_1.xsvf and
rename it to xtp.xsvf.
3. Boot up the testhead.
4. Launch the Diagnostics application.
5. Select Configuration > Programmable Card Config and
check that the Expected value is 11110111_1.
6. Click Update All (F1) button to program all the Control
XTP cards on the testhead.
7. Reboot the testhead.
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Agenda
1. Software Milestone
2. What’s new in 08.30p?
3. How to get 08.30p?
• Access to Software and Licenses
• Redeem License
Page 33 July 2012
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Access to Software and Licenses
Email notification informed availability of Medalist i3070 Software 08.30p
Page 34 July 2012
Access ASM Website
Add Subscription
Access Subscription
Download Documents,
SW, & redeem LicensesRequest SW Media
Shipment
i3x7x 08.30p Software Release
- Release Notes, SW Installation Guide
- ISO file (~3GB in size)
Email Notification
ICT Software Update for Installed Based customer
- Enter Order Number & Certification provided
EMT_ICT_i3070_SYS
EMT_ICT_i3070_TDW
ICT Software Updates for the Field and IDC
- EMT_ICT_FIELD (if you have subscribed, proceed with the next step)
Installed customer select “UPDATE KIT I3X7X 08.30p” to see the overview.
Field and IDC partners select “Update kit of i3x7x 08.30p for field only” to see the overview.
Login to ASM
• https://software.business.agilent.com/asm/
• First time user, please register for an account
Medalist In-Circuit Test 08.30p Software Release
Agilent Confidential
Redeem Ext_App_DLL feature license
Page 35 July 2012
1. Get License assign Mac address
2. Specify your email address
3. License file will be emailed
immediately
- An added value feature for 08.30p software release.
- Distributed to user as FOC with testhead SUS only.