INTRODUCTION TO MECHATRONICS SYSTEM
EXP NO:1 DATE:
AIM:
To study about the important features, about Mechatronics system.
INTRODUCTION TO MECHATRONICS SYSTEM:
Mechatronics is one of the new and existing fields on the engineering landscape, subsuming parts of traditional engineering fields and requiring a broader approach to the design of system that we can formally call as Mechatronics system.
Many industries improving their works through automation which is based on the inter connection between the electronic control systems and mechanical engineering.
Such control systems generally use microprocessors as controllers and have electrical sensors extracting information from mechanical inputs through electrical actuators to mechanical systems.
This can be considered to be application of computer based digital control techniques through electronic and electric interfaces to mechanical engineering problems. Successful design of Mechatronics can lead to products that are extremely attractive to customer in quality cost-effectiveness.
MECHATRONICS DEFINITION:
Mechatronics may be defined as a multi-disciplinary field of study that implies the synergistic integration of electronic engineering, electric engineering, control engineering and computer technology with mechanical engineering for the design, manufacture, analysis and maintenance of a wide range of engineering products and processes.
1
![Page 2: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/2.jpg)
“Mechatronics brings together areas of technology involving sensors and
measurement systems, drive and actuation systems, analysis of the behavior of
systems microprocessor systems”.
The integration across the traditional boundaries of mechanical
engineering, electrical engineering, electronics and control engineering has to
occur at the earliest stages of the design process if cheaper, more reliable;
more flexible systems are to be developed.
APPLICATIONS OF MECHATRONICS ENGINEERING:
Mechatronics engineering finds application in the following fields.
• Electronic home appliances
• Electronic entertainment products
• Engine systems(cars)
• Large scale application
2
![Page 3: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/3.jpg)
Schematic Layout of Hydraulic System
BASIC COMPONENTS OF A HYDRAULICSYSTEM:
Reservoir (or air tank):
A reservoir is an oil supply tank. It is provided to hold the hydraulic liquid
(usually oil).
Pump:
The pump is used to force the liquid into the system.Primemover:
A Prime mover, usually an electric motor, is used to drive the pump.
3
![Page 4: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/4.jpg)
Valves:
Valves are refitted in the system to control liquid direction, pressure, and flow rate.
Actuator:
An actuator is provided to convert the liquid energy into mechanical
force or torque to do useful work. The actuator is the actual working element of
the system. The actuators can be either cylinders (to provide linear motion) or
hydro motors (to provide rotary motion).
Fluid-transfer piping:
The hydraulic Piping is provided to carry the compressed liquid from one
place to another.
Schematic Layout of Pneumatic System
4
![Page 5: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/5.jpg)
BASIC COMPONENTS OF A PNEUMATIC SYSTEM:
Reservoir (or air tank):
An air tank is provided to store the compressed air required for the operations.
Compressor:
The compressor is used to compress the atmospheric air so as to increase
the pressure of the air.
Prime mover:
A Prime mover, usually an electric motor, is used to drive the compressor.
Valves:
Valves are refitted in the system to control air direction, pressure, and flow rate.
Actuator:
An actuator is provided to convert the air energy into mechanical force
or torque to do useful work.
Fluid-transfer piping:
Piping is provided to carry the compressed air from one place to another.
5
![Page 6: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/6.jpg)
BASIC SYMBOLS USED IN HYDRAULIS AND PNEUMATICSYSTEM:
Symbols DescriptionLINES
-continuous line – flow line
-dashed line - pilot, drain-envelope - long and short dashes around two or more component symbols
CIRCULAR-large circle - pump, motor
-small circle - Measuring devices
-semi-circle – rotary actuatorSQUARE
-one square - pressure control function-two or three adjacent squares - directional control
DIAMOND-diamond - Fluid conditioner (filter, separator, lubricator, heat exchanger)
MISCELLANEOUSSYMBOLS
-Spring
-Flow Restriction
TRIANGLE-solid - Direction of Hydraulic Fluid Flow
-open - Direction of Pneumatic flow
PUMPS ANDCOMPRESSORSFixed Displacement Hydraulic Pump
-unidirectional
-bidirectional
6
![Page 7: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/7.jpg)
Variable Displacement Hydraulic Pump
-unidirectional
Compressor
-CompressorSymbols Description
MOTORSFixed Displacement Hydraulic Motor
-unidirectional
-bidirectional
Variable Displacement Hydraulic Motor
-unidirectional
-bidirectional
Pneumatic Motor
-unidirectional
-bidirectionalRotary Actuator
-hydraulic
-pneumaticCYLINDERS
Single Acting Cylinder
-returned by external force
-returned by spring or extended by spring forceDouble Acting Cylinders
-single piston rod (fluid required to extend and retract)
7
![Page 8: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/8.jpg)
-double ended piston rod
Cylinders With Cushions
- single fixed cushion- double fixed cushion
- single adjustable cushion
- double adjustable cushion
Symbols Description
DIRECTIONAL CONTROLVALVESDirectional Control Valve (2 Ports / 2Positions)
-Normally closed directional control valve with 2 ports and 2 finite positions.-Normally open directional control valve with 2 ports and 2 finite positions.
Directional Control Valve (3 Ports / 2Positions)-Normally closed directional control valve with 3 ports and 2 finite positions.-Normally open directional control valve with 3 ports and 2 finite positions.
Directional Control Valve (4 Ports / 2Positions)-directional control valve with 4 ports and 2 finite positions
Directional Control Valve (4 Ports / 3Positions)-directional control valve with 4 ports and 3 finite positions*-(center position can have various flow paths)
Directional Control Valve (5 Ports / 2 Positions) Normally A Pneumatic Valve
-directional control valve with 5 ports and 2 finite positions
Directional Control Valve (5 Ports / 3 Positions) Normally A Pneumatic Valve
8
![Page 9: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/9.jpg)
-directional control valve with 5 ports and 3 finite positions
CONTROLMETHODSManual Control
-general symbol (without showing the control type)
-pushbutton
-lever
-foot pedal
Mechanical Control
-plunger or tracer
-springSymbols Description
-roller
-roller(one direction only)
Electrical Control
-Solenoid (the one winding)
Pilot Operation-pneumatic
-hydraulic
Pilot Operated Two-Stage Valve
-Pneumatic: Sol first stage
-Pneumatic: Air pilot second stage
-Hydraulic: Sol first stage
-Hydraulic: Hydraulic pilot second stage
9
![Page 10: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/10.jpg)
CHECK VALVES, SHUTTLE VALVES, RAPID EXHAUSTVALVES
-check valve -free flow one direction, blocked flow in other direction
-pilot operated check valve, pilot to close
-pilot operated check valve, pilot to open
Shuttle Valve-to isolate one part of a system from an alternate part of circuit
Rapid Exhaust Valve/Pneumatic
-installed close to an actuator for rapid movement of the actuator
PRESSURE CONTROLVALVES
Pressure Relief Valve(Safety Valve) Normally Closed
- Line pressure is limited to the setting of the valve, secondary part is directed to tank
Symbols Description
Proportional Pressure Relief
- line pressure is limited to and proportional to an electronic signal
Sequence Valve
- When the line pressure reaches the setting of the valve, valve opens permitting flow to the secondary port. The pilot must be externally drained to tank.
Pressure Reducing Valve- pressure downstream of valve is limited to the setting of the valve
10
![Page 11: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/11.jpg)
FLOW CONTROLVALVES
Throttle valve
-adjustable output flowFlow Control Valve
-with fixed output (variations in inlet pressure do not affect rate of flow)-with fixed output and relief port to reservoir with relief for excess flow (variations in inlet pressure do not affect rate of flow)-with variable output
-fixed orifice-metered flow toward right free flow to left
-pressure compensated flow control fixed output flow regardless of load-pressure and temperature compensated
-with variable output and relief port to reservoir
Flow Dividing Valve
-flow is divided equally to two outputs
SHUT-OFFVALVE-Simplified symbol
Symbols
Description
FILTERS, WATER TRAPS, LUBRICATORS AND MISCELLANEOUS APPARATUSFilter or Strainer
-filter
Water Trap
11
![Page 12: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/12.jpg)
-with manual drain
-with automatic drained
Filter With Water Trap
-with manual drain
-automatic drain
Air Dryer- refrigerant, or chemical removal of water from compressed airline
Lubricator
-oil vapor is indicted into airline
Conditioning unit
-compound symbol of filter, regulator, lubricator unit
-Simplified Symbol
RESULT:
Thus the important feature Mechatronics system was studied.
12
![Page 13: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/13.jpg)
NORMAL POSITION
13
![Page 14: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/14.jpg)
OPERATION OF SINGLE ACTING CYLINDER USING DCV
EXP NO:2a DATE:
AIM:
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Pneumatic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
3/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
14
![Page 15: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/15.jpg)
ACTUATED POSITION
15
![Page 16: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/16.jpg)
RESULT:
Thus the single acting cylinder was operated using DCV in Pneumatic Trainer Kit.
NORMAL POSITION
16
![Page 17: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/17.jpg)
17
![Page 18: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/18.jpg)
OPERATION OF DOUBLE ACTING CYLINDER USING DCV
EXP NO:2b DATE:
AIM:
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Pneumatic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder
18
![Page 19: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/19.jpg)
ACTUATED POSITION
19
![Page 20: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/20.jpg)
RESULT:
Thus the double acting cylinder was operated using DCV in Pneumatic Trainer Kit.
NORMAL POSITION
20
![Page 21: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/21.jpg)
21
![Page 22: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/22.jpg)
OPERATION OF DOUBLE ACTING CYLINDER WITH AND LOGIC
CIRCUIT
EXP NO: 2c DATE:
AIM:
To operate a double acting cylinder using AND logic circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Pilot Operated DCV
3/2 Hand Levered DCV
Two Pressure Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
22
![Page 23: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/23.jpg)
ACTUATED POSITION
23
![Page 24: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/24.jpg)
RESULT:
Thus the double acting cylinder using AND logic circuit was operated
in Pneumatic Trainer Kit.
24
![Page 25: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/25.jpg)
NORMAL POSITION
25
![Page 26: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/26.jpg)
OPERATION OF DOUBLE ACTING CYLINDER WITH OR LOGIC
CIRCUIT
EXP NO: 2d DATE:
AIM:
To operate a double acting cylinder using OR logic circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
4/2 Pilot Operated DCV
3/2 Hand Levered DCV
Shuttle Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
26
![Page 27: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/27.jpg)
ACTUATED POSITION
27
![Page 28: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/28.jpg)
RESULT:
Thus the double acting cylinder using OR logic circuit was operated
in Pneumatic Trainer Kit.
28
![Page 29: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/29.jpg)
NORMAL POSITION
29
![Page 30: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/30.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS USING CASCADING METHOD (A+B+B-A-)
EXP NO: 2e DATE:
AIM:
To operate a single cycle automation of multiple cylinders in cascading method (A+B+B-A-) in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
3/2 Push Button Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
30
![Page 31: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/31.jpg)
ACTUATED POSITION
31
![Page 32: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/32.jpg)
RESULT:
Thus the single cycle automation of multiple cylinders was operated
by cascading method (A+B+B-A-) in Pneumatic Trainer Kit.
32
![Page 33: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/33.jpg)
NORMAL POSITION
IMPULSE PILOT OPERATION OF SINGLE ACTING CYLINDER
EXP NO: 2f DATE:
33
![Page 34: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/34.jpg)
AIM:
To operate a single acting cylinder using an impulse pilot valve in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
3/2 Hand Levered Spring Return DCV
3/2 Pilot Operated Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
34
![Page 35: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/35.jpg)
35
![Page 36: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/36.jpg)
RESULT:
Thus the single acting cylinder was operated using an impulse pilot valve
in Pneumatic Trainer Kit.
NORMAL POSITION
36
![Page 37: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/37.jpg)
CONTROLLING THE SPEED OF THE CYLINDER USING METERING IN VALVE CIRCUIT
EXP NO: 2g DATE:
AIM:
To control the speed of double acting cylinder using Metering In valve circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Flow Control Valve
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
37
![Page 38: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/38.jpg)
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
38
![Page 39: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/39.jpg)
39
![Page 40: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/40.jpg)
RESULT:
Thus the speed of double acting cylinder was controlled using Metering In
valve circuit in Pneumatic Trainer Kit.
NORMAL POSITION
40
![Page 41: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/41.jpg)
41
![Page 42: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/42.jpg)
CONTROLLING THE SPEED OF THE CYLINDER USING METERING OUT VALVE CIRCUIT
EXP NO: 2h DATE:
AIM:
To control the speed of double acting cylinder using Metering Out valve circuit in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Flow Control Valve
4/2 Hand Levered Spring Return DCV
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
42
![Page 43: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/43.jpg)
ACTUATED POSITION
43
![Page 44: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/44.jpg)
RESULT:
Thus the speed of double acting cylinder was controlled using Metering Out
valve circuit in Pneumatic Trainer Kit.
NORMAL POSITION
44
![Page 45: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/45.jpg)
SINGLE CYCLE AUTOMATION OF DOUBLE ACTING CYLINDER USING LIMIT SWITCH
45
![Page 46: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/46.jpg)
EXP NO: 2i DATE:
AIM:
To operate automatic operation of a double acting cylinder in a single cycle using limit switch in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
46
![Page 47: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/47.jpg)
47
![Page 48: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/48.jpg)
RESULT:
Thus the single cycle automation of double acting cylinder was operated by
using limit switch in Pneumatic Trainer Kit.
NORMAL POSITION
48
![Page 49: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/49.jpg)
MULTI CYCLE AUTOMATION OF DOUBLE ACTING CYLINDER USING LIMIT SWITCH
49
![Page 50: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/50.jpg)
EXP NO: 2j DATE:
AIM:
To operate automatic operation of a double acting cylinder in a multi cycle using limit switch in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
50
![Page 51: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/51.jpg)
51
![Page 52: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/52.jpg)
RESULT:
Thus the multi cycle automation of double acting cylinder was operated by
using limit switch in Pneumatic Trainer Kit.
NORMAL POSITION
52
![Page 53: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/53.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS IN SEQUENCE (A+ B+ A-B-)
53
![Page 54: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/54.jpg)
EXP NO: 2k DATE:
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in Sequence
(A+ B+ A-B-) in Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
3/2 Roller Operated Spring Return DCV
3/2 Push Button Spring Return DCV
4/2 Pilot Operated DCV
Limit Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
54
![Page 55: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/55.jpg)
55
![Page 56: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/56.jpg)
RESULT:
Thus the single cycle automation of multiple cylinders was operated
sequence (A+B+A-B-) in Pneumatic Trainer Kit.
NORMAL POSITION
56
![Page 57: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/57.jpg)
57
![Page 58: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/58.jpg)
OPERATION OF SINGLE ACTING CYLINDER USING SINGLE SOLENOID VALVE
EXP NO: 3a DATE:
AIM:
To operate a single acting cylinder using the single solenoid valve in Electro
Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Single Acting Cylinder
Input / Output Relay Box
3/2 Solenoid Operated Spring Return Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM(P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
58
![Page 59: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/59.jpg)
ACTUATED POSITION
59
![Page 60: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/60.jpg)
RESULT:
60
![Page 61: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/61.jpg)
Thus the single acting cylinder was operated using single solenoid valve
in Electro Pneumatic Trainer Kit
NORMAL POSITION
61
![Page 62: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/62.jpg)
OPERATION OF DOUBLE ACTING CYLINDER USING SINGLE SOLENOID VALVE
EXP NO: 3b DATE:
AIM:
To operate a double acting cylinder using the single solenoid valve in
Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated Spring Return Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
62
![Page 63: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/63.jpg)
ACTUATED POSITION
63
![Page 64: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/64.jpg)
RESULT:
Thus the double acting cylinder was operated using single solenoid valve
in Electro Pneumatic Trainer Kit.
64
![Page 65: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/65.jpg)
NORMAL POSITION
65
![Page 66: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/66.jpg)
OPERATION OF DOUBLE ACTING CYLINDER USING DOUBLE SOLENOID VALVE
EXP NO: 3c DATE:
AIM:
To operate a single acting cylinder using the double solenoid valve in
Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated Valve
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
66
![Page 67: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/67.jpg)
ACTUATED POSITION
67
![Page 68: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/68.jpg)
RESULT:
Thus the double acting cylinder was operated using double solenoid
68
![Page 69: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/69.jpg)
valve in Electro Pneumatic Trainer Kit.
NORMAL POSITION
69
![Page 70: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/70.jpg)
SINGLE CYCLE AUTOMATION OF DOUBLE ACTING CYLINDER
EXP NO: 3d DATE:
AIM:
To operate automatic operation of a double acting cylinder in a single cycle
using electrical switch in Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
70
![Page 71: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/71.jpg)
ACTUATED POSITION
71
![Page 72: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/72.jpg)
72
![Page 73: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/73.jpg)
RESULT:
Thus the single cycle automation of double acting cylinder was operated
by using electrical switch in Electro Pneumatic Trainer Kit.
NORMAL POSITION
73
![Page 74: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/74.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS IN SEQUENCE (A+B+B-A-)
EXP NO: 3e DATE:
74
![Page 75: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/75.jpg)
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in sequence (A+B+B-A-) in Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
75
![Page 76: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/76.jpg)
76
![Page 77: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/77.jpg)
RESULT:
Thus the single cycle automation of multiple cylinders was operated
sequence (A+B+B-A-) in Electro Pneumatic Trainer Kit.
NORMAL POSITION
77
![Page 78: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/78.jpg)
MULTI CYCLE AUTOMATION OF DOUBLE ACTING CYLINDER
78
![Page 79: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/79.jpg)
EXP NO: 3f DATE:
AIM:
To operate automatic operation of a double acting cylinder in a multi cycle
using electrical switch in Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM (P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
ACTUATED POSITION
79
![Page 80: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/80.jpg)
80
![Page 81: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/81.jpg)
RESULT:
Thus the multi cycle automation of double acting cylinder was operated by
using electrical switch in Electro Pneumatic Trainer Kit.
81
![Page 82: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/82.jpg)
NORMAL POSITION
82
![Page 83: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/83.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS IN SEQUENCE (A+B+A-B-)
EXP NO: 3e DATE:
AIM:
To operate the Single Cycle Automation of Multiple Cylinders in sequence (A+B+A-B-) in Electro Pneumatic Trainer Kit.
APPARATUS REQUIRED:
FLUIDSIM(P) Software
Double Acting Cylinder
Input / Output Relay Box
4/2 Solenoid Operated DCV
Electrical Switch
FRL Unit
PROCEDURE:
Draw the circuit in FLUIDSIM (P) software and check the connections.
Connect the FRL unit to the main air supply.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage of air supply and correct it.
Open the valve and operate the cylinder.
83
![Page 84: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/84.jpg)
ACTUATED POSITION
84
![Page 85: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/85.jpg)
RESULT:
Thus the single cycle automation of multiple cylinders was operated
sequence (A+B+A-B-) in Electro Pneumatic Trainer Kit.
85
![Page 86: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/86.jpg)
NORMAL POSITION
86
![Page 87: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/87.jpg)
ACTUATION OF SINGLE ACTING CYLINDER WITH ON DELAY TIMER USING PLC
EXP NO: 4a DATE:
AIM:
To simulate the single acting cylinder with ON Delay Timer using PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
87
![Page 88: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/88.jpg)
ACTUATED POSITION
88
![Page 89: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/89.jpg)
RESULT:
Thus the actuation of single acting cylinder with ON Delay Timer was done using PLC.
NORMAL POSITION
89
![Page 90: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/90.jpg)
90
![Page 91: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/91.jpg)
ACTUATION OF SINGLE ACTING CYLINDER WITH OFF DELAY TIMER USING PLC
EXP NO: 4b DATE:
AIM:
To simulate the single acting cylinder with OFF Delay Timer using PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
91
![Page 92: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/92.jpg)
ACTUATED POSITION
92
![Page 93: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/93.jpg)
RESULT:
Thus the actuation of single acting cylinder with OFF Delay Timer was done using PLC.
93
![Page 94: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/94.jpg)
NORMAL POSITION
94
![Page 95: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/95.jpg)
OPERATION OF SINGLE ACTING CYLINDER WITH AND LOGIC USING PLC
EXP NO: 4c DATE:
AIM:
To simulate the Operation of Single Acting Cylinder with AND Logic using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
95
![Page 96: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/96.jpg)
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
96
![Page 97: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/97.jpg)
97
![Page 98: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/98.jpg)
RESULT:
Thus the single acting cylinder is actuated with AND logic using PLC
NORMAL POSITION
98
![Page 99: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/99.jpg)
OPERATION OF SINGLE ACTING CYLINDER WITH OR LOGIC USING PLC
EXP NO: 4d DATE:
99
![Page 100: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/100.jpg)
AIM:
To simulate the Operation of Single Acting Cylinder with OR Logic using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Sometimes delay the cylinder should be activated.
ACTUATED POSITION
100
![Page 101: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/101.jpg)
101
![Page 102: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/102.jpg)
RESULT:
Thus the single acting cylinder is actuated with OR logic using PLC.
NORMAL POSITION
102
![Page 103: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/103.jpg)
103
![Page 104: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/104.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS IN SEQUENCE (A+B+B-A-) USING PLC
EXP NO: 4e DATE:
AIM:
To simulate the Single Cycle Automation of Multiple Cylinders in sequence (A+B+B-A-) using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Flow Control Valve
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the versa pro software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Both Outputs of PLC (Q1, Q2, Q3 and Q4) are direct connecting to inputs
of solenoid coils.
Following the opening procedure of Codesys software.
Check the ladder diagram Sometimes delay the cylinder should be activated.
104
![Page 105: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/105.jpg)
ACTUATED POSITION
105
![Page 106: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/106.jpg)
Connect the air supply to FRL unit.
Run the PLC.
Observe the working of double acting cylinder is automatic
reciprocating using the circuit A+B+B-A-.
RESULT:
Thus the single cycle automation of multiple cylinders is operated in
sequence (A+B+B-A-) using PLC.
106
![Page 107: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/107.jpg)
NORMAL POSITION
107
![Page 108: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/108.jpg)
CONTROL OF DOUBLE ACTING CYLINDER WITH UP COUNTER USING PLC
EXP NO: 4f DATE:
AIM:
To simulate the double acting cylinder with UP Counter Using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC..
108
![Page 109: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/109.jpg)
ACTUATED POSITION
109
![Page 110: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/110.jpg)
RESULT:
110
![Page 111: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/111.jpg)
Thus the double acting cylinder is actuated with UP Counter using
PLC
NORMAL POSITION
111
![Page 112: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/112.jpg)
CONTROL OF DOUBLE ACTING CYLINDER WITH DOWN COUNTER USING PLC
EXP NO: 4g DATE:
AIM:
To simulate the double acting cylinder with DOWN Counter Using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
112
![Page 113: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/113.jpg)
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
ACTUATED POSITION
113
![Page 114: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/114.jpg)
114
![Page 115: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/115.jpg)
RESULT:
Thus the double acting cylinder is actuated with DOWN Counter
using PLC
NORMAL POSITION
115
![Page 116: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/116.jpg)
AUTOMATION OF SINGLE ACTING CYLINDER USING PLC
116
![Page 117: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/117.jpg)
EXP NO: 4h DATE:
AIM:
To simulate the Automation sequence of Single Acting Cylinder Using PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
3/2 Solenoid Operated DCV
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Observe the working of single acting cylinder is automatic reciprocating.
ACTUATED POSITION
117
![Page 118: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/118.jpg)
118
![Page 119: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/119.jpg)
RESULT:
Thus the automation of single acting cylinder is done by using PLC.
NORMAL POSITION
119
![Page 120: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/120.jpg)
120
![Page 121: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/121.jpg)
AUTOMATION OF DOUBLE ACTING CYLINDER USING PLC
EXP NO: 4i DATE:
AIM:
To simulate the Automation sequence of Double Acting Cylinder Using PLC.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Double Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the Codesys software in desktop.
Interface PLC with PC using RS232 cable.
Write a ladder diagram.
Output of PLC (Q1) is direct connecting to input of solenoid coil.
Following the opening procedure of Codesys software.
Check the ladder diagram.
Connect the air supply to FRL unit.
Run the PLC.
Observe the working of double acting cylinder is automatic reciprocating
121
![Page 122: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/122.jpg)
ACTUATED POSITION
122
![Page 123: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/123.jpg)
RESULT:
Thus the automation of double acting cylinder is done by using PLC.
123
![Page 124: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/124.jpg)
NORMAL POSITION
124
![Page 125: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/125.jpg)
SINGLE CYCLE AUTOMATION OF MULTIPLE CYLINDERS IN SEQUENCE (A+B+A-B-) USING PLC
EXP NO: 4e DATE:
AIM:
To simulate the Single Cycle Automation of Multiple Cylinders in sequence (A+B+A-B-) using PLC
.
APPARATUS REQUIRED:
Compressor
FRL Unit
5/2 Solenoid Operated DCV
Flow Control Valve
Single Acting Cylinder
PLC
Codesys Software.
PROCEDURE:
Draw the circuit diagram.
Provide +24V and –24V from PLC trainer to panel.
Open the versa pro software in desktop.
Interface PLC with PC using RS232cable.
Write a ladder diagram.
Both Outputs of PLC (Q1, Q2, Q3 and Q4) are direct connecting to inputs
of solenoid coils.
Following the opening procedure of Codesys software.
Check the ladder diagram Sometimes delay the cylinder should be
activated.
125
![Page 126: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/126.jpg)
ACTUATED POSITION
126
![Page 127: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/127.jpg)
Connect the air supply to FRLunit.
Run the PLC.
Observe the working of double acting cylinder is automatic
reciprocating using the circuit A+B+A-B-.
RESULT:
127
![Page 128: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/128.jpg)
Thus the single cycle automation of multiple cylinders is operated in
sequence (A+B+A-B-) using PLC.
NORMAL POSITION
128
![Page 129: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/129.jpg)
OPERATION OF SINGLE ACTING CYLINDER USING DCV
EXP NO:5a DATE:
AIM:
To operate a single acting cylinder using the Directional Control Valve (DCV)
in Hydraulic Trainer Kit.
APPARATUSREQUIRED:
FLUIDSIM (H) Software
Single Acting Cylinder
3/2 Solenoid DCV
Pump
PROCEDURE:
Draw the circuit in FLUIDSIM (H) software and check the connections.
The various components are connected as per circuit.
Block the valve openings if necessary.
Check the leakage and correct it.
Open the valve and operate the cylinder.
129
![Page 130: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/130.jpg)
ACTUATED POSITION
130
![Page 131: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/131.jpg)
131
![Page 132: MECHATRONICS LAB MANUAOL 2.docx](https://reader035.fdocuments.us/reader035/viewer/2022081421/577c77a11a28abe0548ce0a5/html5/thumbnails/132.jpg)
RESULT:
Thus the single acting cylinder was operated using DCV in Hydraulic Trainer Kit
132