MCS Certification and data acquisition techniques

18
MCS CERTIFICATION AND DATA ACQUISITION TECHNIQUES 10KW DUAL REGULATED KAPLAN TURBINE

description

MCS Certification and data acquisition techniques. 10kW Dual Regulated Kaplan Turbine. What’s it all About?. MCS Certification. What was the Purpose? What Will I Show You?. Introduction 1. MCS Certification 2. Obtaining the Data 3. The Results. Obtaining the Data. What was the Purpose? - PowerPoint PPT Presentation

Transcript of MCS Certification and data acquisition techniques

Page 1: MCS Certification and data acquisition techniques

MCS CERTIFICATION AND DATA ACQUISITION TECHNIQUES

10KW DUAL REGULATED KAPLAN TURBINE

Page 2: MCS Certification and data acquisition techniques

2

• MCS Certification1

• Challenge of Obtaining Data2

• All Exciting, RESULTS! (And the Road to Getting Them)3

WHAT’S IT ALL ABOUT?

Page 3: MCS Certification and data acquisition techniques

3

MCS CERTIFICATION

• What was the Purpose?

• What Will I Show You?

Introduction1. MCS Certification2. Obtaining the Data3. The Results

Page 4: MCS Certification and data acquisition techniques

4

OBTAINING THE DATA

Introduction1. MCS Certification2. Obtaining the Data3. The Results

• What was the Purpose?

• What Will I Show You?

Page 5: MCS Certification and data acquisition techniques

5

THE RESULTS

• What was the Purpose?

• What Will I Show You?

Introduction1. MCS Certification2. Obtaining the Data3. The Results

Page 6: MCS Certification and data acquisition techniques

6

MCS CERTIFICATION

Current Situation?

Why Bother?

How Does One Obtain Certification?

Page 7: MCS Certification and data acquisition techniques

7

OBTAINING DATAWhat data did we need?

• Electrical power output• Upstream River Level• Turbine Tank Level• Downstream River Level• Water Velocity…(to be continued!)– And actuator positions……Identifies steady state

conditions

Page 8: MCS Certification and data acquisition techniques

8

POWER READINGS RIVER LEVELS

Page 9: MCS Certification and data acquisition techniques

9

OBTAINING FLOW DATA

• PITOT-STATIC TUBE

• Insertion Flow Meter Required

(Bright Hub Engineering, 2010) (Setra Solutions, 2014)

=0.235 psi = 2.9e-3 psi

£900!+/- 0.25ms-1

(Voelkner, 2014)

Other options considered, but there just isn’t time!

Page 10: MCS Certification and data acquisition techniques

10

OBTAINING FLOW DATA

WHAT WE ACTUALLY USED!

Page 11: MCS Certification and data acquisition techniques

11

OBTAINING RUN-AWAY DATA

Page 12: MCS Certification and data acquisition techniques

12

PROBLEMS

• Flow Regime

• Calibration

• Second Run

• Reliability of flow meter?

Page 13: MCS Certification and data acquisition techniques

13

CALCULATIONSɳ=

𝑃𝑀𝐸𝐶𝐻

𝑃𝑇𝐻

h𝑃𝑡 =𝑔 ·𝐻𝑛𝑒𝑡 ·𝑄𝑎

Page 14: MCS Certification and data acquisition techniques

14

CALCULATIONSSOURCES OF HEAD LOSS

Page 15: MCS Certification and data acquisition techniques

15

The Fish Screen

Inlets (Sudden Contraction)

Frictional Losses

Outlet (Sudden Expansion)

Gradual Expansions

1. At The 90ᵒ Bend

Page 16: MCS Certification and data acquisition techniques

16

Time Spent

Proj

ects

Wor

ked

On

Get Familiar

Achieve Mastery

Working Toward Mastery

Get Experience

d

Page 17: MCS Certification and data acquisition techniques

17

Doing Your Best Work

• Working from home• Working offsite• Technology

requirements

Page 18: MCS Certification and data acquisition techniques

18