BHAGWAN MAHAVIR COLLEGE OF ARCHITECTURE
Subject : Environmental Science
Topic : Mahoney Table for LOS ANGELES CITY
Faculty :- Ar. Dhruvita Mahida Ar.Nirav khandwala
Prepared By :- Yatharth Thakkar (82)
Months Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Monthly mean max. 20.1 20.3 21.2 22.6 23.6 25.6 28.4 29.1 28.4 25.8 22.7 19.8
Monthly mean min. 8.8 9.6 10.6 11.9 13.6 15.7 17.8 17.3 17.3 14.8 11.1 8.6
Monthly mean range 14.4 14.9 15.9 17.2 18.6 20.6 23 23.4 22.8 20.3 16.9 14.2
HumidityGroup
AverageRH
1 BELOW 30%
2 30 – 50%
3 50 – 70%
4 ABOVE 70%
HIGH AMT
29.1 23.9
8.6 13.1
LOW AMR
Months Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Monthly mean max. 20.1 20.3 21.2 22.6 23.6 25.6 28.4 29.1 28.4 25.8 22.7 19.8
Monthly mean min. 8.8 9.6 10.6 11.9 13.6 15.7 17.8 17.3 17.3 14.8 11.1 8.6
Monthly mean range 14.4 14.9 15.9 17.2 18.6 20.6 23 23.4 22.8 20.3 16.9 14.2
Air Temperature : ° C
Relative Humidity: (%)
COMFERT LIMIT FOR DIFFERENT HUMIDITY GROUPS
MonthsAMT OVER 20°C AMT 15 - 20°C AMT BELOW 15°C
DAY NIGHT DAY NIGHT DAY NIGHT
1 26 - 34 17 -25 23 - 32 14 - 23 21 – 30 12 - 21
2 25 - 31 17 - 24 22 - 30 14 - 22 20 - 27 12 - 20
3 23 - 29 17 - 23 21 - 28 14 - 21 19 - 26 12 - 19
4 22 - 27 17 - 21 20 - 25 14 - 20 18 - 24 12 - 18
Months Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec TOTAL
Rainfall (mm) 79.2 96.5 61.7 23.1 2.3 0.3 1 6.1 16.8 26.4 35.7 59.2 379.2
AVERAGE MONTHLY TEMPERATURE IS 26.95° C AS PER ABOVE SLIDE
DAY COMFERT (UPPER) = 27 ° CDAY COMFERT (LOWER) = 22° C
NIGHT COMFERT (UPPER) = 21 ° CNIGHT COMFERT (LOWER) = 17° C
Diagnosis: ° CMonths Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Monthly mean max. 20.1 20.3 21.2 22.6 23.6 25.6 28.4 29.1 28.4 25.8 22.7 19.8
Day comfort upper 29 29 29 27 27 27 27 27 27 29 29 29
Lower 23 23 23 22 22 22 22 22 22 23 23 23
Monthly mean min. 8.8 9.6 10.6 11.9 13.6 15.7 17.8 17.3 17.3 14.8 11.1 8.6
Night comfort Upper 23 23 23 21 21 21 21 21 21 23 23 23
Lower 17 17 17 17 17 17 17 17 17 17 17 17
Thermal stress day C C C O O O H H H O O C
Night C C C C C C O O O C C C
DATA TAKEN FROM FIRST TABLEO = COMFERTABLE CLIMATE= MONTHY MAX. & MIN. ARE BETWEEN UPPER & LOWER LIMITC = COLD CLIMATE= MONTHY MAX. & MIN. ARE BELOW LOWER LIMITH = HOT CLIMATE= MONTHY MAX. & MIN. ARE ABOVE UPPER LIMIT
INDICATORS
THERMAL STRESS
RAINFALL HUMIDITY GROUP
MONTHLY MEAN RANGE
DAY NIGHT
H1H 4H 2,3 LESS THAN 10
H2 O
H3 OVER 200 mm
A1 1,2,3 MORE THAN 10
A2 H 1,2
H O 1,2
A3 C
Months Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec TOTAL
Humid H1 √ √ √ 3
H2 √ √ √ √ √ 5
H3
Arid A1 √ √ √ √ √ √ 6
A2 √ √ √ 03
A3 √ √ √ √ √ √ √ √ √ 9
Table For Selecting Indicators
Indicators
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS
0-10√ 1 Orientation north & south
(long axis east-west)
11,125-12
0-4 2 Compact courtyard planning
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS
11,12 √ 3 Open spacing for breeze penetration
2-10 4 As 3, but protection from hot & cold wind
0,1 5 Compact layout of estates
Layout:
Spacing:
Indicator totals H1 H2 H3 A1 A2 A33 5 4 6 3 9
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS0-2 12 Light walls, short time-lag
3-12 13 Heavy external & internal walls
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS0-5 14 Light, insulated roofs
6-12 15 Heavy roofs, over 8 hr. time-lag
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS2-12 16 Space for out-door sleeping required
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS3-12 √ 17 Protection from heavy rain necessary
Walls:
Roofs:
Out Door Sleeping:
Rain protection:
Indicator totals H1 H2 H3 A1 A2 A33 5 4 6 3 9
Indicator totals H1 H2 H3 A1 A2 A33 5 4 6 3 9
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS
0,10 1 Large : 40-80%
1-122 Medium: 25-40%
2-5
6-10 3 Small: 15-25%
11,120-3 4 Very small: 10-20%
4-12 5 Medium: 25-40%
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS
3-12
√ 6 In north & south walls at body height on wind ward side
1-20-5
6-127 As above, openings also in internal
walls0 2-12
Size of opening:
Position of opening:
Indicator totals H1 H2 H3 A1 A2 A33 5 4 6 3 9
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS0-2 8 Exclude direct sunlight
2-12 √ 9 Provide protection from rain
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS0-2 10 Low thermal capacity
3-12 11 Heavy, over 8 hr. time-lag
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS10-12 0-2 √ 12 Light, reflective surface, cavity
3-1213 Light, well insulated
0-9 0-5
6-12 14 `
Protection of openings:
Walls & Floors:
Roofs:
Indicator totals H1 H2 H3 A1 A2 A33 5 4 6 3 9
H1 H2 H3 A1 A2 A3 DESIGN CRITERIAS
1-12 15 Space for out-door sleeping
1-12 √ 16 Adequate rain water drainage
External features: