LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit,...
Transcript of LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit,...
![Page 1: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/1.jpg)
TR04-05
(2004.XX.000XX)NK
Head Office. Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, 530-8323 Japan.
Tel: 06-6373-4338
Fax: 06-6373-7297
Tokyo Office. JR Shinagawa East Bldg., 10F 18-1, Konan 2-chome, Minato-ku Tokyo, 108-0075 Japan.
Tel: 03-6716-0420
Fax: 03-6716-0230
TR04-05
Marine type Container Refrigeration Unit
LXE10E-A27
Service Manual・Parts List
Optional Functions
![Page 2: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/2.jpg)
1 1
Covered ModelsRegarding the features and operation of the unit, this service manualdescribes the items which are different from those of the service manualTR01-09A.
NO. ItemDifferent points from service manual(Maintenance and Repair)
1☆ Debumidification function Refer to the details in the following pages.
For the ☆ marked items, refer to the details in the following pages.
2☆ Trans FRESH (PROVISION) Provided
![Page 3: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/3.jpg)
2
*Diffirences from standard model service manual (TR01-09A) are marked with ☆
CONTENTS3.10 Chartless function .....................................3-56
3.10.1 Chart indication function.....................3-563.10.2 P code (Pull down time indication) .....3-583.10.3 Chartless code display function..........3-59
3.10.3.1 List of chartless code...................3-593.10.3.2 H-code.........................................3-603.10.3.3 d-code: ........................................3-62
3.11 Communication modem ............................3-634. Service and Maintenance .................................4-1
4.1 Maintenance service .....................................4-14.1.1 Collection of refrigerant ..........................4-14.1.2 Gauge manifold ......................................4-14.1.3 Automatic pump down............................4-34.1.4 Refrigerant recovery and charge............4-5
4.2 Main components and maintenance .............4-94.2.1 Scroll compressor...................................4-94.2.2 Fan and fan motor ................................4-114.2.3 PT and CT board (EC9756) .................4-124.2.4 Electronic expansion valve...................4-144.2.5 Suction modulation valve .....................4-154.2.6 Drier......................................................4-164.2.7 Solenoid valve ......................................4-174.2.8 Discharge pressure regulating valve ....4-184.2.9 Check valve..........................................4-184.2.10 High-pressure switch (HPS) ...............4-194.2.11 Low pressure transducer (LPT)..........4-194.2.12 High pressure transducer (HPT) ........4-204.2.13 Air-cooled condenser and evaporator ...4-204.2.14 Fusible plug ........................................4-214.2.15 Liquid/moisture indicator ....................4-214.2.16 Evacuation and dehydrating...............4-22
5. Optional Devices...............................................5-15.1 Electronic temperature recorder....................5-15.2 USDA transportation .....................................5-3
5.2.1 Type of USDA sensor/receptacle ...........5-35.2.2 Initial setting ...........................................5-35.2.3 USDA sensor calibration ........................5-35.2.4 USDA transportation requirement ..........5-35.2.5 USDA report ...........................................5-3
5.3 TransFRESH.................................................5-56. Troubleshooting................................................6-1
6.1 Refrigeration system and electrical system...6-16.2 Alarm codes on electronic controller .............6-46.3 Troubleshooting for automatic PTI (J-code) ...6-96.4 Diagnosis based on the recording chart......6-116.5 Emergency operation ..................................6-14
6.5.1 Emergency operation of controller .......6-146.5.2 Short circuit operation of controller.......6-156.5.3 Opening adjustment of electronic expansion valve...6-166.5.4 Opening adjustment of suction modulation valve: ...6-176.5.5 Automatic Back up for supply/ return air
temperature sensors ............................6-186.6 Troubleshooting for automatic PTI (J-code)...6-19
7. Appendix............................................................7-17.1 Standard tightening torques for bolts ............7-17.2 Standard tightening torque for flare nut.........7-17.3 Resistance of motor coil and solenoid valve coil ...7-17.4 HFC134a, temperature-vapor pressure characteristics table ...7-27.5 Temperature conversion table and temperature sensor
(SS/RS/DSS/DRS/RSS/RRS/EIS/EOS/SGS/AMBS)characteristics table.............................................7-3
7.6 Temperature conversion table and temperaturesensor (DCHS) characteristics table ................7-4
7.7 High pressure transducer characteristics table...7-47.8 Low pressure transducer characteristics table...7-47.9 Piping diagram ..............................................7-57.10 Pilot lamps and monitoring circuit ...............7-67.11 Fuse protection table...................................7-77.12 Schematic wiring diagram...........................7-97.13 Stereoscopic wiring diagram.....................7-10
Safety Precautions• Danger .................................................................3• Warning................................................................4• Caution.................................................................5
1. Introduction .......................................................1-11.1 Operation range ............................................1-11.2 Basic Names of components ........................1-11.3 Basic operation of refrigeration unit ..............1-2
1.3.1 Starting operation ...................................1-21.3.2 Checking during operation .....................1-31.3.3 Procedure after operation.......................1-31.3.4 Adjust the ventilation ..............................1-4
2. General description ..........................................2-12.1 Main specifications........................................2-12.2 Names of components ..................................2-2
2.2.1 Outside ...................................................2-22.2.2 Inside......................................................2-42.2.3 Control box .............................................2-6
2.3 Set point of functional parts and protection devices...2-92.4 Operating pressure and running current .....2-102.5 Operation modes and control......................2-14
2.5.1 Frozen mode ........................................2-152.5.2 Chilled and partial frozen mode............2-172.5.3 Defrosting mode ...................................2-192.5.4 Dehumidification mode (Optional) ........2-222.5.5 Common control ...................................2-23
3. Electronic Controller.........................................3-13.1 Function table................................................3-13.2 Basic operation of electronic controller .........3-3
3.2.1 Control panel ..........................................3-33.2.2 Operation mode and control...................3-5
3.3 Operation procedure .....................................3-63.3.1 Operation procedure flow chart ..............3-63.3.2 Mode operation procedure .....................3-9
1. Current (Operation state) indication mode ...3-92. Operation setting mode ........................3-103. Battery mode ........................................3-114. Mode operation ....................................3-125. LED display light-OFF mode ................3-146. Sensor indication mode........................3-157. Temperature record scroll mode ..........3-188. Alarm record scroll mode .....................3-219. PTI record scroll mode .........................3-23
3.3.3 Setting flow chart..................................3-2410. Optional function setting mode...........3-2611. Basic function setting mode ...............3-2712. Optional condition setting mode .........3-2913. Input data mode .................................3-3114. Controller software download mode...3-32
3.4 Alarm display and back-up function ............3-333.4.1 Alarm list...............................................3-333.4.2 Back-up operation at sensor malfunction...3-34
3.5 Battery.........................................................3-363.5.1 Specifications .......................................3-363.5.2 Function................................................3-37
3.6 Information interchange with personal computer...3-373.6.1 Data logging .........................................3-383.6.2 Software configuration..........................3-39
3.7 Inspection procedure for the electronic controller...3-413.8 Controller replacement and the initial setting...3-42
3.8.1 Controller replacement .........................3-423.8.2 Initial setting & operation procedure.....3-433.8.3 Initial setting table into spare controller ...3-44
3.9 PTI (Pre-Trip Inspection) and periodic inspection...3-453.9.1 Inspection item .....................................3-463.9.2 Automatic PTI (Pre-Trip Inspection) .....3-49
3.9.2.1 PTI selection mode........................3-503.9.2.2 Short PTI (S.PTI) ...........................3-513.9.2.3 Full PTI (F.PTI) ..............................3-523.9.2.4 Alarm list during PTI (Pre-Trip Inspection) ...3-533.9.2.5 Manual check (M.CHECK) ............3-54
☆
☆
☆
☆
☆
☆
☆
☆
☆
☆
☆
![Page 4: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/4.jpg)
31-1
1. Introduction
1.1 OPERATION RANGE
Use the units within the following range.
1.2 BASIC NAMES OF COMPONENTS
Ambient temperature range
Inside temperature range
Voltage
Vibration and shock
Operation range
-30˚C to +50˚C (-22˚F to + 122˚F)
-30˚C to +30˚C (-22˚F to + 86˚F)
50Hz: 380V/400V/415V, 60Hz: 440V/460V Voltage fluctuation rate should be within ±10%
2G
Item
1 1 2
1 3
6
1 0
4
11
5
9
8
2
3
7
q Compressor
w Air-cooled condenser
e Receiver
r Evaporator
t Control box
Outside: switch, manual defrost switch, monitoring
receptacle
Inside: circuit breaker
y Condenser fan
u Drier
i Access panel
o Storage space for power cable
!0 Ventilator
!1 Sampling port (Return) Use this port to measure the
inside return air temperature.
!2 Gas sampling port This is used to measure the
Sampling port (Supply) inside supply air temperature
and inside CO2 concentration.
!3 Liquid moisture indicator
![Page 5: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/5.jpg)
4 2-1
2. General description
2.1 Main specifications
Model
ItemLXE10E
Condenser cooling system Air cooled type
Controller DECOS3C
Power supply AC 3-phase 380V/400V/415V 50Hz, 440V/460V 60Hz
Compressor Hermetic scroll type (Motor output: 5.5kW)
Evaporator Cross fin coil type
Air-cooled condenser Cross fin coil type
Evaporator fan Propeller fan
Evaporator fan motor Three-phase squirrel-cage induction motor
Condenser fan Propeller fan
Condenser fan motor Three-phase squirrel-cage induction motor
Def
rost
ing Hot-gas defrosting system
Dual timer, on-demand defrost and manual switch
Detecting the temperature of evaporator outlet pipe and return air
Electronic expansion valve
Capacity control Capacity control with hot gas bypass and suction modulating valve
Protective devices
/Safety devices
Circuit breaker, PT/CT board (for over current protection).
Condenser fan-motor thermal protector
Evaporator fan-motor thermal protector
High-pressure switch, Fusible plug, Fuse (10A, 5A)
Refrigerant (charged amount) R134a : 4.6 (kgf)
Refrigerant oil (charged amount) IDEMITSU, Daphne hermetic oil FVC 46D : 2.2(R)
Weight 495(kgf)
System
Initiation
Termination
Refrigerant flow control
Compressor thermal protector
![Page 6: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/6.jpg)
52-2
2.2 Names of components2.2.1 Outside
�LXE10E
q Access panelw Thermometer check port (Return air)e Condenser fan motor (CFM)r Hot-gas solenoid valve (HSV)t Defrost solenoid valve (DSV)y Discharge gas by-pass solenoid valve (BSV)u Electronic expansion valve (EV)i Economizer solenoid valve (ESV)o Injection solenoid valve (ISV)!0 Air-cooled condenser!1 Liquid/moisture indicator!2 Liquid receiver!3 Drier!4 Liquid solenoid valve (LSV)!5 Suction modulating valve (SMV)
!6 Discharge pressure regulating valve (DPR)!7 Compressor suction pipe temperature
sensor (SGS)!8 Ambient temperature sensor (AMBS)!9 Thermometer check port (Supply air)@0 Compressor (MC)@1 Discharge pipe temperature sensor
(DCHS)@2 Storage space for power cable @3 Low pressure transducer (LPT)@4 High pressure transducer (HPT)@5 High pressure switch (HPS)@6 Control box@7 Ventilation@8 Reheat coil solenoid valve (RSV)
2 1 2 0 1 9 1 8 1 7
7
1 1
5
9
2 7
3
2 4
2
2 6
2 2
1
1 0
8
1 4
1 2
2 5
1 3
6
2 3
1 6 1 5
4
2 8
![Page 7: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/7.jpg)
6 2-4
2.2.2 Inside�LXE10E
q Evaporator fan motor (EFM)w Evaporatore Supply air temperature sensor (SS)
Data recorder supply air temperature sensor (DSS)Recorder supply air temperature sensor (RSS, optional)
r Evaporator outlet pipe temperature sensor (EOS)t Evaporator inlet pipe temperature sensor (EIS)y Return air temperature sensor (RS)
Data recorder return air temperature sensor (DRS, optional)Recorder return air temperature sensor (DRS, optional)
u USDA receptacle (optional)i Cargo temp. receptacleso P.C. Port receptacles!0 Humidity sensor!1 Reheat coil
1 0 6
5
4
1
2
1 1
7
8
9
3
![Page 8: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/8.jpg)
72-6
2.2.3 Control box
q Controller operation panel (EC3, 4)w MANUAL DEFROST key e UNIT ON/OFF keyr Phase correction contactor (PCC1,2)t Magnetic contactor for high speed evaporator fan (EFH)y Magnetic contactor for low speed evaporator fan (EFL)u Magnetic contactor condenser fan (CFC)i Reverse phase protection device (RPP)o Adopter PCB (EC6)!0 Terminal block board (TB1)!1 Controller CPU / IO board (EC1, 2)
!2 Fuse (Fu1-6)!3 Rechargeable battery (BAT)!4 Voltage indicator!5 Personal computer receptacle!6 Circuit breaker (CB)!7 PT/CT board!8 Transformer (TrC), control circuit!9 Magnetic contactor for compressor (CC)@0 P.C.B for humidity sensor (HUS, optional)@1 Modem (RCD, optional)@2 Noise filter (NF, optional)
�Operation panel(Outside of the control box)
�Controller
�Inside of the control box
23
1
3
1
2
b
– 1 2 – 1 0 – 8 – 6 – 4 – 2
– 2– 3– 4– 5– 6 – 1
S P – 5
O V E R
2
I N R A N G E
H O U R S
D A Y S
1
U N D E R
A L A R MR . H .
S U P P L YR E T U R N ˚C / ˚F
%R H
D E F R O S T I N R A N G E D – H U M I DC O M P .
˚C
˚C
S P +5
D E C O SD A I K I N E L E C T R O N I C C O N T A I N E R O P E R A T I O N S Y S T E M
2 0
P A K - 6 1 J C
1 09
2 2
1 5 2 1
4
1 4
1 7
5
1 1
1 3
1 1
1 6
8
P A K - 6 1 J C
1 9
P A K - 6 1 J C
1 2
7
1 8
B4P
–VH
B4P
–VH
F U S E
6
B 3 P S V H
R A – H 3 4 1 T D
B5P-VH
3 5 JP A K -
![Page 9: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/9.jpg)
8 2-9
Device name Actuation Set point Detection method Symbol
High-pressure switch OFF 2400kPa (24.47kg/cm2) High-pressure switch HPS
ON 1900kPa (19.37kg/cm2)
Water pressure switch OFF 98kPa (1.0kg/cm2) Water pressure switch WPS
(optional) ON 39kPa (0.4kg/cm2)
Chilled mode ON +30.0°C to –2.9°C Set point temperature EC
(+86.0°F to +26.8°F)
Mode selectionPartial frozen mode –3.0°C to –10.0°C
(+26.6°F to +14.0°F)
Frozen mode –10.1°C to –30.0°C
(+13.8°F to –22.0°F)
Delay Fan Change-over for Hi/Lo ON 10 seconds
timer After defrosting 60 seconds
Compressor At starting 3 seconds
Defrosting Short ON 4 hours ※1
timer Long 3, 6, 9, 12, 24 and 99 hours(※2)
Back-up OFF 90 minutes
In-range masking 90 minutes ※3
Out-range guard ON 30 minutes
Defrosting termination set point OFF 30˚C (86°F) Evaporator outlet EOS
Reset tempertature sensor
15˚C (59°F) ※4 Return air temperature RS, DRS
sensor
High-pressure control for Condenser fan OFF 800kPa (8.2kg/cm2) ※7 High-pressure transducer HPT
(※Frozen only) ON 1000kPa (10.2kg/cm2)
Discharge gas Pull down OFF 135˚C (275°F) Discharge gas DCHS
temperature LPT>50kpa Reset After 3 minutes elapsed temperature sensor
protection LPT≦50kpa OFF 128˚C (262°F)
set point Reset After 3 minutes elapsed
Overcurrent protection set point (Cutout) OFF 26.0A PT/CT board CT2
Reset After 3 minutes elapsed
Current control Control 50Hz : 16.1A PT/CT board CT1
60Hz : 17.4A
High pressure control Control 2300 to 2350 kPa High pressure sensor HPT
(23.5 to 24.0 kg/cm2)
Circuit breaker OFF 30A CB
Fuse OFF 5A, 10A ※5 Fu
Evaporator fan motor thermal protector OFF 132˚C (270°F)
Condenser fan motor thermal protector OFF 135˚C (275°F) MTP
Compressor motor thermal protector OFF 140˚C (284°F) CTP
2.3 Set point of functional parts and protection devicesE
lect
roni
cco
ntro
ller
Initia
tion
Cur
rent
Mot
orPr
essu
resw
itch
(※1) When Return air (RS) is lower than –20˚C, defrost starts every 6 hours.(※2) When "99" hours is selected, refer to on demand defrost in 2.5.3. (TR01-09A)(※3) When Inside set point is –20.0˚C or Lower, In-range masking is 120min.(※4) If defrost is initiated when inside temperature is out rangle area. (= In-range LED is not light), this condition is added to
finish defrost. Refer to "Defrosting termination" in 2.5.3. (TR01-09A)(※5) Refer to "Fuse Protection table" in 7.11. (TR01-09A)(※7) When dehumidification is ON in dehumidification mode, the setting figure may change between 900~2100kPa
automatically (Refer to "High Pressure Control" Page 2-17/TR01-09A)
![Page 10: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/10.jpg)
92-14
2.4 OPERATION MODES AND CONTROLThe relationship between the operation mode and setting temperature is as follows.
Operation mode Setting temperature Control sensor Operation description
Frozen mode–10.1˚C to –30.0˚C Return air
Compressor ON/OFF control(+13.8˚F to –22.0˚F) temperature sensor
Partial frozen –3.0˚C to –10.0˚C Return airCapacity control operation
mode (+26.6˚F to +14˚F) temperature sensorwith suction modulating valveand hot-gas bypass control
+30.0˚C to –2.9˚C Supply airCapacity control operation
Chilled mode(+86˚F to +26.8˚F) temperature sensor
with suction modulating valveand hot-gas bypass control
Defrosting mode – –Hot-gas defrosting withrefrigerant metering control
![Page 11: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/11.jpg)
10 2-22
3 Dehumidification modeThe unit have dehumidification control by a reheat coil, which is under the evaporator coil. To executedehumidification, controller setting is required. (Refer to Page 3-12)In dehumidification, the Reheat Solenoid Valve (RSV) opens to give high pressurized refrigerant to reheatcoil. The "DEHUMID" LED lamp will light up.The following setting can be made:1) Dehumidification range: 60%RH–95%RH
![Page 12: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/12.jpg)
113-12
Press the key in current indication mode to go to MODE operation.
In mode operation, the following settings/operations are available.
1. Generator setting
Total power consumption can be reduced to desired Max setting for the specific generators set or
power facilities.
The selections are "off (No limit)", "15" "14" "13" "12" "11" KVA.
2. Automatic pump down
Pump down can be executed automatically.
(Refer to "Automatic pump down" in 4.1.3/TR01-09A)
3. Dehumidification mode setting
Dehumidification mode can be executed in this mode (M. Dehumidification mode control in
2.5.4/TR01-09A)
When "Dehumidification" is set to "on", it is possible to change the following set from default.
qInside humidity : 95% ~60% RH
M
MODE
MODEOPERATION
All indicationLights on
(for 3 sec.)
StartingPreparation(for 18 sec.)
Currentindication
(Operation state)
※1
M
MODE
4. Mode Operation
![Page 13: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/13.jpg)
12 3-33
5 Alarm display and back-up function5.1 Alarm listAlarm Alarm
Alarm content Action with alarmgrouping codeF101 HPS activated within 30 seconds after operation start or protection device Unit stops
activated 5 times at start-up operation or Fuse 1 brown (Refer Page 7-7).F109 Low- pressure drops to–85kPa or lower within 2 seconds after operation start. Unit stopsF111 HPS does not activate when it reaches to the set value. Unit stopsF301 Temperature setting required (SRAM failure) Unit stopsF401 Return/Supply air sensor malfunction (at chilled mode) Unit stopsF403 Return/Supply air sensor malfunction (at partial frozen mode) Unit stopsF603 Suction modulating valve (SMV) does not fully close contrary to the designation
or initial setting of the controller is wrong. Unit stopsF701 Abnormal high voltage (over 600V) Unit stopsF705 S phase became open phase Unit stopsF803 Abnormalities, which make it impossible to continue operation (Note2.) Unit stopsE101 High-pressure switch activated during normal operation. Restart after 3-minuteE103 CTP or electronic OC activated during normal operation. Restart after 3-minuteE105 Micro processor OC activated during normal operation. Restart after 3-minuteE107 DCHS became abnormal high temperature during operation. Restart after 3-minute
In the event the refrigerant circulation rate is low, the unit If this error occurs two times, F803will stand by for three minutes to restart then. error will be detected to stop the unit.
E109 Low pressure drops to–90kPa or lower for 2 seconds Restart after 3-minuteor longer successively during normal operaton.
E201 Pump down is not completed within 90 seconds. Only alarm displayE203 Overcool protection activates in the chilled or partial frozen mode. Restart after 3-minutes
(Control temperature ≦ SP–3˚C or for 3 minutes)E205 Evaporator for motor failure Only alarm displayE207 Defrosting is not completed within 90 minutes Only alarm displayE303 Humidity setting required (SRAM failure) Only alarm displayE305 Defrost timer setting required (SRAM failure) Only alarm displayE307 Calendar setting required (SRAM failure) Only alarm displayE311 Trip-start setting required (SRAM failure) Only alarm displayE315 PT/CT board failure Restart after 3-minutesE401 Supply air temperature sensor (SS) malfunction Back-up operationE402 Data recorder supply air temperature sensor (DSS) malfunction Back-up operationE403 Return air temperature sensor (RS) malfunction Back-up operationE404 Data recorder return air temperature sensor (DRS) malfunction Back-up operationE405 Discharge air temperature sensor (DCHS) malfunction Only alarm displayE406 Suction gas temperature sensor (SGS) malfunction Back-up operationE407 Evaporator inlet temperature sensor (EIS) malfunction Back-up operationE409 Evaporator outlet sensor (EOS) malfunction Back-up operationE411 Ambient sensor (AMBS) malfunction Only alarm displayE413 Low pressure transducer (LPT) malfunction Back-up operationE415 High pressure transducer (HPT) malfunction Back-up operationE417 Voltage sensor (PT1) malfunction Only alarm displayE421 Current sensor (CT1) malfunction Only alarm displayE423 Current sensor (CT2) malfunction Restart after 3-minutesE425 Pulp temperature sensor (USDA1) malfunction Only alarm displayE427 Pulp temperature sensor (USDA2) malfunction Only alarm displayE429 Pulp temperature sensor (USDA3) malfunction Only alarm displayE431 Humidity sensor (HuS) malfunction Only alarm displayE433 Cargo temperature sensor (CTS) or box temperature sensor Only alarm display
(CBS) malfunctionE603 Suction modulating valve (SMV) malfunction or driver malfunction Back-up operationE607 MDS (sheet key) malfunction Only alarm displayE707 Momentary power failure Restart after 3-minutes
E801 Backup battery replacement date exceeded Only alarm display
Per
man
ents
top
Dis
play
alon
eor
rest
arta
ble
alar
m
Prote
ction
devic
eacti
vatio
nCo
ntro
lerro
rPr
inte
d-cir
cuit
boar
dfa
ilure
Sen
sor
alar
mEl
ectro
nicfu
nctio
nal
part
alarm
Pow
ersu
pply
alar
mO
hter
alar
m
Note 1) The alarm LED does not blink when E code alarm is generated.To check if any alarm generates, use alarm indication function in the section "1. Current indicationmode" of "3.3.2 Mode operation procedure.
2) In the event error E101, E103, E107, or E109 occurs 10 times, the system will go to 4-hour standbymode.
3) In case of sensor malfunction, the judgment for sensor malfunction does not perform for 3 minutesbefore the pressure or temperature reaches to the specified value.
![Page 14: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/14.jpg)
133-36
6 Battery
6.1 SpecificationsDECOS 3c controller can use two types of batteries; Alkaline or Rechargeable (Optional). It is not possibleto exchange the type of battery afterwards.The battery is positioned on CPU & I/O box in controller box.Alkaline: 9V block battery. (This can be purchased locally.)Rechargeable: DAIKIN original rechargeable battery
6.2 FunctionThis battery is used without main power supply for the following functions.
1) Display wake up (Refer to chapter 3.3.2) page 3-11.Setting/Display the following items on the LCD display.<Display>
Temperature on the return air sensorTemperature on the supply air sensor
<Setting change>Inside temperature, defrosting interval, dehumidifying set (Optional), Unit ON/OFF
2) USDA data logUSDA sensors data log every 1 hourNote) When the Alkaline battery is equipped, it must be replaced for a new every PTI, when USDA is
used.
3) Trip data logTrip data; Setting point, Supply air, Return air, Humidity and time is logged every 1 hour after power off
until battery run out. (Min. 3 days)
6.3 Battery checkAlkaline battery: Press key to confirm the Battery mode workable.
When the power is disconneced.Rechargeable battery: Press "Battery check meter"
Green: OperatableRed: Replace battery
S
![Page 15: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/15.jpg)
14 3-40
B4
P–
VH
B4
P–
VH
F U S E
B 3 P S V H
R A Å | H 3 4 1 T D
B5P-VHRechargeable battery(Battery fixing plate)
Voltage indicator(Battery check meter)
6.4 Battery replacement (Alkaline and Rechargeable battery)Detach the cover of battery and replace the battery
![Page 16: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/16.jpg)
155-5
7 TransFRESHAttachment for the TransFRESH CA devices are provided to control the internal atmosphere (quantity of O2
and CO2).Use the CA devices according to the Operation Manual supplied by TransFRESH. The controller andsensor included in the CA devices are installed by the TransFRESH's agents before each transportation.
�An example of installation of CA devices, outside.
qTransFRESH COMMUNICATION BRACKET
wTransFRESH Single purge port
※A2, A3 cables (provision only) are provided.However, terminal connections are not performed in the control box.
q
w
![Page 17: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/17.jpg)
16 4-14
8 Electronic expansion valve� Model Coil : EBM-MD12DM-1
Body : EDM-B804DM-1This unit adopts an electronic expansion valve.The electronic expansion valve controls theoptimum refrigerant flow rate automatically,using the temperature sensor at the evaporatorinlet and outlet pipes.In case of emergency including controllermalfunctions, refer to the chapter oftroubleshooting, section 6.5, Emergencyoperation.
(1) Replacing the coilq Loosen the lock nut, then remove the coil
from the body.w Install a new coil. The tightening torque for
installation is 6.9 to 16.7 N � m (70 to 170kgf �cm).
e Restore the binding bands and the lead wireinto the original state.
r After replacing, carry out refrigerant leakagecheck, and make sure that there are no leaks.
(2) Replacing the bodyq Loosen the lock nut, then remove the coil.w Remove the hexagonal head bolts, and cut
the pipe on the body, then remove remainingpipes from brazing parts.
e Connect a new body to the pipes. Be sure toconduct brazing work while cooling the bodybelow 120˚C (248˚F) by using wet cloths.
r Fix the body to the mounting base.t Remove the cap, and mount the coil with the
tightening torque of 6.9 to 16.7 N � m (70 to170kgf � cm).
y After replacing, carry out refrigerant leakagecheck, and make sure that there are no leaks.
e Body
q Coil
w Lock nut
y Cap
q Coil
w Lock nut
e Mounting baser Hexagon head bolt
t Body
u Apply a sillicon sealant to the lock nut section.
Seal using withsillicon Sealant
![Page 18: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/18.jpg)
177-5
9. APPENDIX
9.1 Piping diagram
HEAT EXCHANGER
EV
SERVICE PORT (HIGH)(QUICK JOINT TYPE)
SERVICE PORT (HIGH)(QUICK JOINT TYPE)
SERVICE PORT (HIGH)(QUICK JOINT TYPE)
LIQUID INDICATOR
DRIER
SMVSERVICE PORT (LOW)(QUICK JOINT TYPE)
CHECK VALVE RECEIVER
RSV
HSV
DSV
DPR
BSV
ISV
LSV
ESV
HEAT EXCHANGER
EV:Electronic Expansion Valve SMV:Suction Modulation Valve DPR:Discharge pressure regulator
LSV:Liquid Solenoid Valve HSV:Hot Gas Solenoid Valve
DSV:Defrost Solenoid Valve ISV:Injection Solenoid Valve
ESV:Economizer Solenoid Valve BSV:Discharge Gas Bypass Solenoid Valve
![Page 19: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/19.jpg)
![Page 20: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/20.jpg)
9.2 Schematic wiring diagram
19
![Page 21: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/21.jpg)
9.3 Stereoscopic wiring diagram
20
![Page 22: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/22.jpg)
ORDERING INSTRUCTIONS
The parts list contains the parts of the DAIKIN Marine Type Container Refrigeration Units. Please read the following items before using the list.1. When ordering the parts, be sure to specify the model No., the name of part and the type
of part. When ordering the parts for which no parts NO. is shown in the PARTS NO.column, be sure to describe DWG.NO..
2. The list shows the parts only for replacement or repairing at the job site. Certain partsrequire a production lead time or are supplied as a set, so please contact with the nearestDAIKIN PARTS CENTRE.
3. Index symbols;Meaning of the ranking A,B and C are as follows;A. The most important spare parts
1. The parts whose malfunction cause fatal damage to the unit.2. The parts with high risk of malfunction.3. The parts that are worn out after an extended service period.
B. The important spare parts next to A, but the risk of malfunction is not so high.C. The parts with low risk of malfunction, but recommendable to stock to cope with
damage during handling of container box and long delivery time, etc.The parts without A, B and C mark is the parts whose necessity is not so high undernormal operation.
パーツリスト使用上の注意
このパーツリストはダイキン海上コンテナ冷凍装置の部品を集録してあります。パーツリスト使用にあたっては、必ず次の注意事項をご一読の上使用していただくようお願いいたします。
1.部品のご注文の際は機種名、部品番号、および部品名、形式を必ずご指定ください。なお、部品番号欄が空白になっている部品は、図面番号で指示願います。
2.掲載部品の範囲は、あくまでも現地にて分解修理できるところまで記載しております。一部部品につき納期のかかるものおよびセット単位となるものもありますので、お近くのダイキンパーツセンター又はサービスステーションに相談願います。
3.INDEXの説明INDEXのA、B、Cの意味は下記の通りです。A. 最も重要な部品1.故障した場合に最も重大な損害を与えると思われる部品2.故障の確率が高いと思われる部品3.長期の使用で摩耗して使用できなくなる部品B. 故障発生の確率は高くはないが、Aについで重要な部品C. 故障発生の確率は低いが、コンテナボックスの運搬中の事故や、部品の納期が長期になると思われる等の理由で、在庫をお勧めする部品
A,B,Cマークの無い部品は、通常の運転では必要性は高くない部品です。
21
![Page 23: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/23.jpg)
Denomination of Model Name
L X E E
NOMINAL HORSE POWER 5 : 510 : 10
CONDENSER COOLING TYPE NIL : AIR and WATER COOLED TYPE A : AIR COOLED TYPE
OPTION NUMBER
機種名について�
L X E E
称呼馬力� 5 : 5 10 : 10
凝縮器冷却方式�なし:空水冷兼用形� A :空冷専用形�
オプション番号�
Note) "R" GIVEN AFTER OPTION NUMBER STANDS FOR "REVISION"AND IT IS GIVEN FOR THE UNIT WHICH IS SPECIALLYMODIFIED.
注)オプション番号の後に R がつく機種は、改造機で、特別な仕様が加えられていることを意味します。
22
![Page 24: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/24.jpg)
23
C O N T E N T S
目 次
Page
A. Parts related with the unit(outside)………………………………………………………………………24庫外関連部品
B. Parts related with refrigerant piping(outside) …………………………………………………………26庫外冷媒配管関連部品
C. Parts related with the unit(inside) ………………………………………………………………………30庫内関連部品
D. Parts related with refrigerant piping(inside) …………………………………………………………34庫内冷媒配管関連部品
E. Other parts(Pipe clamp, sealing and insulation material etc.) …………………………………………36その他部品(配管固定具、シール材、防熱材等)
F. Control box …………………………………………………………………………………………………44コントローラボックス
G. Parts related with name plate ……………………………………………………………………………48銘板関連
I. Parts related with option 1 – USDA………………………………………………………………………50オプション関連部品1 - USDA関連
J. Parts related with option 2 – MODEM …………………………………………………………………52オプション関連部品2 -モデム
K. Parts related with option 3 – Others ……………………………………………………………………54オプション関連部品3 - その他
1. Indoor fan guard 庫内ファンガード2. Evaporator coil 蒸発器コイル組立品
L. Parts related with option 4 – TRANS – FLESH ………………………………………………………56オプション関連部品4 - トランス・フレッシュ
M.List of size for standard pipe clamp ……………………………………………………………………58配管固定具サイズ表
1. Resin clamp 樹脂バンド2. Tube clamp 管止金3. Cushion rubber for pipe clamp 管止金用緩衝ゴム
N. Notes for ordering spare parts……………………………………………………………………………60部品発注の際の注意事項
1. Parts recommended to be ordered together with packing, gasket, sealing material and name plate発注の際にパッキングやシール材、銘板等の同時発注を推奨する部品
2. Order for motorized valve, solenoid valve and pressure regulating valve電動弁・電磁弁・圧力調整弁の発注
3. Order for pressure transducer 圧力センサーの発注4. Order for temperature sensor 温度センサーの発注
O. Measuring and adjusting tools …………………………………………………………………………65測定調整用工具
1. Tools for emergency operation 緊急運転用工具2. Personal computer cable (for DCCS) パソコンケーブル(DCCS用)
![Page 25: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/25.jpg)
Parts related with the unit(outside)庫外関連部品
A20
A19A29
A17
A7
A13
A30A35
A31
A32
A33
A36
A34
A18
A9A8
E13
A1
A35A31
A32
A33A34
A14
A16
A2
A3
A15 (Refer to Page 61)
E55
A11
A10
A12
A5 A6
A4 (Refer to Page 60)
A19
A21
A37
A22
A20
A38
24
![Page 26: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/26.jpg)
Parts related with the unit(outside)庫外関連部品
25
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
A1 1448270 Power plug(400V class) 電源プラグ(400V) 3P109727-1 1
A2 A 0954936 Condenser fan motor 凝縮器電動機 3P005566-1 1
A3 B 0980618 Fan Brade(outside) プロペラファン(庫害側) P44H11S P44H11S 1
A4 C 0980423 Acesses panel ass'y サービス扉組立品 1P006678-1 2 Refer to Page 60
A5 1266207 Cushion material(access panel) クッション材(サービス扉) 3P033608-1 2 Refer to Page 60
A6 1196113 Sealing material (access panel) シール材(サービス扉) 3P001640-2 2 Refer to Page 60
A7 1326705 Wire clamp 電線止め金 4P090422-1 1
A8 C 1266199 Drain hose ドレンホース 3P011299-1 For trap type 1
A9 537320 Hose band ホースバンド R4716528-3 2
A10 1266137 Fan guide stay ass'y(outside) ファンガイドステー組立品(庫外側) 3P027891-1 1
A11 1198652 Fan guide(outside) ファンガイド(庫外側) 1P050906-1 IVORY WHITE 1
A12 C 0983167 Discharge grille 吹出しグリル 1PA53427-1 1
A13 1369663 Mounting plate, front plate(cable) 取付板 4P006981-2 1
A14 1503216 Front plate(cable) 前板(鈑金)(ケーブル) 3P118413-2 1
A15 C 1270338 Front plate(CA) 前板(CA) 2P061345-1 1 Refer to Page 61
A16 1380684 Control, box front plate(left,single) C,BOX前板(左) 2P093861-2 1
A17 1485527 Fixing plate(left) 外板取付板(1) 3P116814-1 1
A18 1311518 Fixing plate(right) 外板取付板(2) 3P047544-2 1
A19 1266120 Ventilation cover 換気口蓋 3P067053-1 1
A29 1496820 Protection cover for thermometer 温度計挿入口保護カバー 4P085921-2 1
A37 1387159 Cap nut キャップナット 4P105737-1 4
E13 1266788 Resin clamp 樹脂バンド NE41015-12 MILK WHITE 4
E55 1267077 Packing for prevention of vibration CA前板ビビリ防止パッキン 4P050050-1 2
A20 B 1266221 Sealing material (access panel) シール材(換気口) 4P016185-1 2
A21 1015858 Wing nut 蝶ナット 4SK06111-5 4
A22 KH66006 M6 wood washer M6木材座金 4SK07006-5 4
A30 1584145 Protection cover for thermometer 温度計挿入口保護カバー 4P085921-3 1
A31 1266238 Hexagon head bolt PC六角ボルト R4290921-125 M12×25 2
A32 1386930 Chain ビクターチェーン 4P063801-1 2
A33 1266245 Tapping screw タッピンネジ 4SK05064-8 M3 SUS304 2
A34 844012S Plain washer 平座金 4SK07005-3 M3SUS 2
A35 1267084 Gasket, resin bolt パッキン樹脂ボルト用 4PA63573-1 2
A36 1270369 Front plate, holding plate(right) 押エ板前板(右) 3P083136-1 1
A38 1584152 Single purge port ass'y シングルパージポート組立品 3P039625-1 1
![Page 27: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/27.jpg)
26
Parts related with refrigerant piping(outside)庫外冷媒配管関連部品
B7-2
B11詳細(Detail of B11)
B13詳細(Detail of B13)
B12詳細(Detail of B12)
B23
B26B11
B13
B23
B12B22
Discharge pipe
Feeler bulb inserting pipe
Feeler bulb
Suction pipe
Feeler bulb inserting pipe
Feeler�bulb
EV
B7-5
B7-5
B7-4B7-4
DSVBSV
HSV
RSV
ISV ESV
B7-4
B7-4
B7-5B7-5
B7a
B7b B7-6
B2
B7-7
B7-7
B7-1
B8-1-1 B8-1
B8-1-2
B8-1-3B8-1-5
B8-1-4
B7-8
B3-6
B11B17
B18
B16
B15
B14B1
B25
B9-2
DPR
B22
B3-4 B4-4
B4
B9-1-2
B9-1-1
B9-1
B9-1-3
B3-2-2
B3-2-1
B3-2
B3-2-3
B4-3
B4-1
B4-6B4-5 B5-1
B10
B4-2
B8B5
B5-2
SMV
B9B3
B6
B8-1
B3-5
B24B3-3
B3-2-2
B3-2
B3-2-1
B3-2-3
LSVB19
B3-1
B20
B12
B13
B6-1
![Page 28: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/28.jpg)
Parts related with refrigerant piping(outside)庫外冷媒配管関連部品
27
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
B2 C 1387173 Air cooled condenser 空冷凝縮器 2P089486-1 CA-LXE10E1 1
B3 Discharge pipe ass'y 吐出配管ASSY 2P117329-1 1
B3-1 C 1199167 Strainer ストレーナ 4P051389-1 1
B3-2 C 1178920 Service valve ass'y サービスバルブ組立品 3P048905-1 3
B3-2-1 B 1175921 Service valve cap キャップ 3P048905-1-KU 3
B3-2-2 Service valve body 本体 3P048905-1-KA 3
B3-2-3 B KAB0001 Valve core バルブコア 3P048905-1-KI 3
B3-3 B 0684220 Check valve 逆止弁 3SA27008-1 1
B3-4 A 1241361 Discharge pressure regulating valve 吐出圧力調整弁 3P074558-1 1 DPR
B3-5 1266276 Flange(convex) 吐出管フランジ(凸) 4P065933-1 1
B3-6 B 292011 Gauge joint(with check valve) 逆止弁付ゲージ接手 2PF00177-1 VCG2DA 1
B6 Injection tube ass'y インジェクション管組立品 3P093305-1 1
B6-1 C 0085296 Strainer ストレーナ R4697892 1
B7a Expansion valve pipe ass'y 膨張弁配管組立品 2P128286-1 1
B7-1 C 1505748 Filter フィルタ 3P011071-1 1
B7-2 C 1490846 Strainer ストレーナ 4P051958-1 1
B7-3 A 1256495 Electronic expansion valve body ass'y 電子膨張弁本体組立品 2SA50010-2-KU 1 EV
B7-4 A 0944566 NEV type solenoid valve body NEV型電磁弁本体 R3305118-1 NEV-803DXF 4 HSV,DSV,BSV,RSV
B8-1-3 1270390 Coil, suction modulating valve 吸入比例弁コイル 2P078385-1-KU 1
B7-5 A 0955287 Solenoid valve coil 電磁弁コイル 3P010453-1 4 HSV,DSV,BSV,RSV
B7b ISV, ESV pipe ass'y ISV,ESV配管組立品 2P115771-1 1
B7-7 A 0955287 Solenoid valve coil 電磁弁コイル 3P010453-1 2 ISV,ESV
B7-8 C 0964166 Strainer ストレーナ 4P012568-1 1
B8 1496781 Suction pipe ass'y 吸入配管ASSY 3P071569-2 1
B8-1 A 1254538 Suction modulating valve ass'y 吸入比例弁ASSY 2P078385-1 1 SMV
B8-1-1 1270376 Upper cover, suction modulating valve 吸入比例弁カバー上 2P078385-1-KA 1
B8-1-2 1496914 Clamp, suction modulating valve 吸入比例弁クランプ 2P078385-1-KI 1
B8-1-4 1270408 Body, suction modulating valve 吸入比例弁弁本体 2P078385-1-KE 1
● When ordering the parts whose No. are not shown in thePARTS NO. column, be sure to describe DWG. NO..
● 部品番号欄が空白になっている部品は、図面番号で、指示願います。
B7-6 B 0088738 Nev type solenoid valve body NEV型電磁弁本体 R3305099-1-KI NEV-202DXF 2 ISV,ESV
B1 A 1199415 Compressor 圧縮機 JT224D-NYR 1
B4 1549685 Liquid receiver ass'y 受液器Assy 2P117335-1 1
B4-1 1266283 Liquid receiver 受液器レシーバ 4P081428-1 φ90×t1.5 1
B4-2 0137856 Flare nut フレアナット 4SK23011-4 FNS4 φ12.7 1
B4-3 A 1498035 Fusible plug 可溶栓 3SA27103-1 1
B4-4 C 0299134 Filter フィルタ 3SA26004-2 1
B4-6 A 0955287 Solenoid valve coil NEV電磁弁コイル 3P010453-1 1
B5 Liquid pipe ass'y 液配管 ASSY 3P065985-1 1
B5-1 0137856 Flare nut フレアナット 4SK23011-4 FNS4 φ12.7 1
B5-2 0622107 Liquid moisture indicator モイスチャーインジケーター 3PA51270-3 SGN12S 1
B4-5 A 0944566 NEV type solenoid valve body NEV型電磁弁本体 R3305118-1 NEV-803DXF 1
![Page 29: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/29.jpg)
Parts related with refrigerant piping(outside)庫外冷媒配管関連部品
28
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
B10 A 1241385 Drier ass'y ドライヤASSY 3P069859-1 1
B11 A 0983321 Sensor, discharge pipe temperature(DCHS) 吐出管用センサ(DCHS) 3SA48009-10 1 Refer to Page 64
B12 A 0798321 Sensor, ambient air temperature(AMBS) 外気温度センサ(AMBS) 3PA61769-6 ST9503-6(NIL) 1 Refer to Page 64
B13 A 0983338 Sensor, comp suction pipe temperature(SGS) 圧縮機吸込配管温度用センサ(SGS) 3PA61769-9 ST9503-9(white) 1 Refer to Page 64
B14 1266322 Cable(comressor) ケーブル(圧縮機) 3P063458-1 1
B15 A 1463983 Low pressure transducer (LPT) 低圧圧力センサ(LPT) 4PA60524-1 SPCL02 1 Refer to Page 64
B16 A 1463976 High pressure transducer (HPT) 高圧圧力センサ(HPT) 4PA60522-1 SPCH01 1 Refer to Page 64
B17 A 1011058 Cable, high-pressure transducer 高圧圧力センサケーブル 3P008835-1 1 Refer to Page 64
B18 A 1011065 Cable, low-pressure transducer 低圧圧力センサケーブル 3P008835-2 1 Refer to Page 64
B19 A 1241378 High pressure switch 高圧圧力開閉器 ACB-KB15 3P071506-1 1
B20 A 1381430 Electronic expansion valve coil 電子膨張弁コイル 2P010454-2 1 EVRefer to Page 62
B22 1266346 Thermostat cover サーモカバー 4P068258-1 1
B23 0423968 Mounting spring,thermistor サーミスタ取付バネ 4PA38890-1 3
B24 A 0132192 Flange packing, compressor discharge 圧縮機吐出側フランジパッキン 4SK20053-4 1
B25 A 0395032 Flange packing, compressor suction 圧縮機吸入側フランジパッキン R4221042-1 1
B26 1267147 Thermal insulation tube 断熱筒(吸入弁庫外側) 4P073602-1 1
B8-1-5 1270376 Cover band, suction modulating valve 吸入比例弁カバーバンド 2P078385-1-KO 1
B9 1496774 Suction piping ass'y(1) 吸入配管ASSY(1) 2P084863-1 1
B9-1 C 1178937 Service valve ass'y サービスバルブ組立品 3P048907-1 1
B9-1-1 B 1178867 Valve core バルブコア 3P048907-1-KI 1
B9-1-2 B Service valve body 本体 3P048907-1-KA 1
B9-1-3 B 1175914 Service valve cap キャップ 3P048907-1-KU 1
B9-2 1266315 Square flange 角フランジ 4PA61542-1 1
● When ordering the parts whose No. are not shown in thePARTS NO. column, be sure to describe DWG. NO..
● 部品番号欄が空白になっている部品は、図面番号で、指示願います。
![Page 30: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/30.jpg)
Parts related with refrigerant piping(outside)庫外冷媒配管関連部品
29
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
![Page 31: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/31.jpg)
Parts related with the unit(inside)庫内関連部品
C36詳細(Detail of C36)
C23詳細(Detail of C23)
C25 DSS(Green・Red)C24 SS(Green)
<Without recorder>
<Without recorder>
C37詳細(Detail of C37)
C27 DRS(Blue・Red)
C26 RS(Blue)
E9
E9
E14 E14F72
C37
C7
C34
C36
C18
C13
C37
C15 C1bC8 C33 C1a
C2
Option
C12
Option
C3C22C6
C6
C5
C4
C19
C19
C23
C17-1
C17-2
C29
C36
C23
C31 C30
C14-2
C14-1
C35
C16
C21
C9
C30 C29
C38C28
C33 E57詳細(Detail of E57)
PUTTY(Equivalent of NEO-SEAL B-1)
Sealing compound(KE44RTV or its equivalent)
E57
INSIDE
OUTSIDE
シール剤�(KE44RTV又は相当品)
パテ�(ネオシールb-1相当品)
E57
30
![Page 32: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/32.jpg)
Parts related with the unit(inside)庫内関連部品
31
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
C1a A 0955333 Therr phase AC fan motor 三相交流ファン電動機(ケーブル付) 3PA07524-4 1 Cable length 2520
C1b A 0955340 Therr phase AC fan motor 三相交流ファン電動機(ケーブル付) 3PA07524-5 1 Cable length 3270
C3 1410958 Center stay(Reheat) 中央ステー(レヒート) 3P094853-1 1
C5 1509531 Side stay(2) サイドステー(2) 3P105384-1 1
C6 1584176 Rear stay(Reheat) 背面ステー(レヒート) 3P103621-2 4
C7 1584183 Casing frame, evaporator(left) 蒸発器枠(3) 2P094765-3 1
C8 1380754 Casing frame, evaporator(right) 蒸発器枠(2) 2P094765-2 1
C9 1494134 Fixing plate, fan guide ファンガイド固定板 3P105378-1 1
C12 1584190 Fan guide ass'y ファンガイドASSY 3P123264-4 1
C13 1565199 Set plate, fan ass'y 電動機取付脚 3P144888-1 4
C14-2 1496938 Rear plate(lower/right) 裏板(下/右) 2P105389-1 1
C15 1266555 Air reflection plate 風向板 4P055257-1 1
C16 1496945 Inspection hole 点検蓋 4P105393-1 1
C17-1 1496952 Rear plate(middle) 裏板(中) 2P105387-1 1
C22 1266524 Support plate 支柱補強柱 4P061342-1 1
C23 1266517 Mounting plate, sensor センサー取付板 3P069038-1 1
C24 A 1375310 Sensor(SS) サーミスタ(SS) 3PA61769-11 ST9503-11(green) 1 Refer to Page 64
C25 A 1375327 Sensor(DSS) サーミスタ(DSS) 3PA61769-12 ST9503-12(green,red) 1 Refer to Page 64
C26 A 1375334 Sensor(RS) サーミスタ(RS) 3PA61769-13 ST9503-13(blue) 1 Refer to Page 64
E14 0508162 Resin clamp 樹脂バンド NE41015-3 Milk whith 1
C31 840002 Drop out prevention washer 脱落防止座金 R4718607-6 2
C33 1560024 Bypass protection plate バイパス防止板 4P120521-1 2
C34 1380848 Cover カバ- 3P090387-1 1
C35 1496976 Fixing, rear plate 固定具(裏板・中) 4P105391-1 2
C36 1380855 Mounting plate, sensor 取付板(センサー) 4P072701-1 1
C37 1380862 RH sensor mounting plate RHセンサ固定板 4P000182-1 1
C38 1496983 Fixing plate, rear plate(upper) 裏板上固定具 4P105390-1 t2.0 1
E9 0118273 Resin clamp 樹脂バンド NE41015-2 Milk whith 5
E57 1267091 Wiring protection bush 配線保護ブッシュ 4P023920-1 BLACK 2
C2 B 0777519 Fan Brade(inside) プロペラファン(庫内側) P32P11F 2
C4 1266360 Side stay サイドステー 3P061281-1 t2.5 1
C14-1 1496921 Rear plate(lower/left) 裏板(下/左) 2P105388-1 1
C17-2 1496969 Rear plate(upper) 裏板(上) 2P105386-1 1
C18 1266485 Partition plate (drain outlet) 仕切板(ドレン出口) 4P011317-1 1
C19 1135978 Reinforce plate, fan motor 補強板(ファン電動機台) 4P011316-1 4
C21 1135125 Hinge 蝶番 3P043374-1 1
C27 A 1375341 Sensor(DRS) サーミスタ(DRS) 3PA61769-14 ST9503-14(blue,red) 1 Refer to Page 64
C28 860015 Universal nut 自在ナット R4713188-1 12
C29 860030S Speed bolt スピードボルト(M6) 4P048680-2 M6X29(S) 18
C30 860005 Washer, speed bolt スピードボルト用座金 R4713334 21
![Page 33: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/33.jpg)
Parts related with the unit(inside)庫内関連部品
32
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
F72 A 0927770 Humidity sensor 湿度センサー 3PA61738-1 1
![Page 34: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/34.jpg)
Parts related with the unit(inside)庫内関連部品
33
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REFER PAGE
参照ページ
![Page 35: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/35.jpg)
Parts related with refrigerant piping(inside)庫内冷媒配管関連部品
D6
D4詳細(Detail of D4)
D5詳細(Detail of D5)
45°
45°E63 D5
E30
~
E60
D7
D4
Feel
er b
ulb
Feeler bulbinserting pipe
D3-1
D3-10
D3-6
D3-2
D3-2
D1
D3-4
D3-3
D2
D8D9
D3-5
D3-7
D3
D3-9
D3-8
D4
D5
34
![Page 36: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/36.jpg)
Parts related with refrigerant piping(inside)庫内冷媒配管関連部品
35
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
D1 C 1380691 Evaporator ass'y 蒸発器組立品 2P071832-1 CRB-LXE10E1 1 With reheat coil
D2 1380893 Drain pan pipe ass'y ドレンパン配管Assy 2P103794-2 1
D3 1564684 Heat exchanger ass'y with insulation 熱交換器防露筒組立品 3P114529-2 1
D3-1 Double tube heat exch. Ass'y 二重管式熱交換器Assy 2P114495-2 1
D3-2 1549762 Insulation tube, gas pipe(1) ガス配管(1)防露筒 3P114518-1 2
D3-3 1549779 Insulation tube, liquid pipe(1) 液配管(1)防露筒 3P114518-2 1
D3-4 1549786 Insulation tube, liquid pipe(2) 液配管(2)防露筒 3P114518-3 1
D3-5 1380918 Thermal insulation tube 断熱筒(熱交外管) 4P103439-1 1
D3-6 1380925 Thermal insulation tube 断熱筒(熱交外管) 4P103439-2 1
D3-7 1380932 Thermal insulation tube 断熱筒(熱交外管) 4P103439-3 1
D3-8 1380949 Thermal insulation tube 断熱筒(熱交外管) 4P103439-4 1
D3-9 1549971 Thermal insulation, gas pipe(3) ガス配管(3)防露筒 3P114518-4 1
D3-10 1549988 Thermal insulation, liquid pipe(3) 液配管(3)防露筒 4P110520-2 2
D6 C 1266308 Filter フィルタ 3P032328-1 1
D8 1380956 Reheater inlet pipe レヒータ入口管 3P101695-2 1
D9 1380963 Reheater outlet pipe レヒータ出口管 3P101696-2 1
E30 537320 Hose band ホースバンド R4716528-3 2
E60 1267123 Thermal insulation tube piping 断熱筒配管緩衝材 4P011309-1 4
E63 1267154 Insulation tube evaporater header 蒸発器ヘッダー防露筒 4P073525-1 1
D4 A 1562828 Sensor(EIS) センサー(EIS) 3P012118-2 ST9703-2 1 Refer to Page 64
D5 A 1562835 Sensor(EOS) センサー(EOS) 3PA61769-15 ST9501-15 1 Refer to Page 64
D7 0423968 Mounting spring,thermistor サーミスタ取付バネ 4PA38890-1 3
● When ordering the parts whose No. are not shown in thePARTS NO. column, be sure to describe DWG. NO..
● 部品番号欄が空白になっている部品は、図面番号で、指示願います。
![Page 37: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/37.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
A詳細(Detail of A)
E断面(Section of E)
B詳細(Detail of B)
Tie wrap
Wires
C詳細(Detail of C)
E19
E73
E91
E83
E85
E82
E79
E80
受液機器部詳細�(Receive part detail)
ドライヤー部詳細�(Dryer part detail)
E32
E8
E7
E33
E33
E34
E2
A
E87
Condenser coil
E111pc
E13
Apply silicone(KE4898 clear)
After apply silicone
E E
A
C
B
36
![Page 38: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/38.jpg)
37
E60
E92
E21E28
E6
E6
E21
E10
E84
E29
E15E5
E16
E88
E2
E16
E89
E17E20L=60mm
E1
E27L=90mm
E25L=50mm
E21
E3
E18
E4
E15
E21
E31L=60mm
E60
E92
E74
E86
D
F
C
K
H
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
※(L = XX mm) indicates the length of cushion rubber E35.(Cut to suit pipe size.)
※(L = XX mm)と表記のものは、緩衝ゴム(E35)の長さです。(配管のサイズに合わせて切って使用ください。)
矢視C/D(View C/D)
矢視H(View H)
圧力センサー配管部詳細(Pressure tranducer piping detail)
冷媒配管詳細 ( Refrigerant piping detail )
矢視F(View F) K部詳細(Detail of K)
![Page 39: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/39.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
E60
E94矢視A(VIEW A)
E15
E98
E97
E81
E81
E11 E12
AE78
E72
E95E23/E52
38
![Page 40: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/40.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
FAN GUIDEファンガイド
E43
E44
E39E39
E54
E42
E45
E37
E46
E46
E38
E37E41E36
A
A部詳細(Detail of A)
E41
E47
Rear plate, upper
Fan guide
39
![Page 41: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/41.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
E77
E76
E64
E67
E66
E65
E93
E63
E69
E90
E40E40
E70
E61
40
![Page 42: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/42.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
41
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REFER PAGE
参照ページ
E1 1266694 Set plate, discharge pipe 吐出配管取付板 4P079462-1 1 Page 37
E2 1266702 Fixture plate, receiver レシーバー固定具 4P011318-2 1 Page 37
E3 1485938 Mounting plate, discharge pipe(2) 吐出配管取付板(2) 4P117351-1 1 Page 37
E4 1485914 Mounting plate, ISV,ESV,EV ISV,ESV,EV取付板 4P115765-1 1 Page 37
E5 1557624 Mounting plate, HSV,DSV,BSV,RSV HSV,DSV,BSV,RSV取付板 4P110770-1 1 Page 37
E6 1270439 Tube clamp 管止金 NE31016-61 2 Page 37
E7 1266764 Fitting band, dryer ドライヤー取付バンド 4PA51194-1 1 Page 36
E8 1266771 Set plate, dryer 取付板(ドライヤ) 4P076788-1 t2.0 1 Page 36
E9 0118273 Resin clamp 樹脂バンド NE41015-2 MILK WHITE 5 Page 30
E10 1222764 Resin clamp 樹脂バンド NE41015-9 MILK WHITE 1 Page 37
E11 0944528 Resin clamp 樹脂バンド NE41015-7 MILK WHITE 2 Page 36,38
E12 0142492 Resin clamp 樹脂バンド NE41015-10 MILK WHITE 2 Page 38
E13 1266788 Resin clamp 樹脂バンド NE41015-12 MILK WHITE 4 Page 36
E15 0782775 Tube clamp 管止め金 NE31016-51 5 Page 37,38
E16 1584208 Tube clamp, Nylon coating 管止め金,ナイロンコーティング 4P143802-52 2 Page 37
E17 1584215 Tube clamp, Nylon coating 管止め金,ナイロンコーティング 4P143802-51 6 Page 37
E18 1584222 Tube clamp, Nylon coating 管止め金,ナイロンコーティング 4P143802-54 1 Page 37
E19 0700090 Tube clamp 管止め金 NE31016-54 1 Page 36
E31 1380970 Hot gas tube clamp ホットガス管止め金 4PA43040-1 1 Page 37
E39 1381036 Packing パッキン 4P095033-1 2 Page 39
E40 1177369 Cushion rubber 仕切用ゴム 4P026657-1 t2.0 2 Page 40
E41 1386954 Sealing packing, fan guide シールパッキン ファンガイド 3P090183-1 1 Page 39
E42 1266973 Sealing material(patch plate2) シール材(当板2) 4P068964-1 1 Page 39
E20 0016290 Tube clamp 管止め金 NE31016-56 1 Page 37
E21 1584239 Tube clamp, Nylon coating 管止め金,ナイロンコーティング 4P143802-71 6 Page 37
E23 1266827 Fixing plate, filter フィルター固定具 4P071794-1 t1.5 1 Page 38
E25 1266841 Tube clamp 管止め金(2) 4P005817-2 1 Page 37
E27 1266858 Tube clamp 管止め金 NE31016-59 1 Page 37
E28 1387180 Tube clamp ホットガス管止め金 4PA43040-2 1 Page 37
E29 1584246 Tube clamp 管止め金 4P143802-59 1 Page 37
E30 537320 Hose band ホースバンド R4716528-3 2 Page 34
E32 1266889 Cushion rubber, pipe clamp 緩衝ゴム(管止用) 4P064896-1 t1.0 1 Page 36
E33 1266896 Seal packing シールパッキン 4P011314-1 1 Page 36
E34 1270446 Dryer cushion rubber ドライヤ緩衝ゴム 4PA53083-2 1 Page 36
E35 1584253 Cushion rubber 緩衝ゴム NE41013-3-300 L=300 1 Page 37
E36 1386947 Sealing material シールパッキン 4P090149-1 t10.0 GRAY 1 Page 39
E37 1266935 Packing(for evaporator) パッキン(蒸発器) 4P063465-1 2 Page 39
E38 1266942 Packing(for evaporator) パッキン(蒸発器) 4P063465-2 1 Page 39
E44 1266997 Sealing material(patch plate1) シール材(当板1) 4P068968-1 2 Page 39
E43 1381043 Sealing material(patch plate3) シール材(当板3) 4P095038-1 1 Page 39
![Page 43: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/43.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
42
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REFER PAGE
参照ページ
E45 1267008 Sealing packing シールパッキン 3P011293-1 1 Page 39
E46 1267015 Packing (side stay) パッキン(サイドステー) 4P074127-1 BLACK 2 Page 39
E47 1326851 Packing(rear plate ) パッキン(裏板上) 3P073551-1 BLACK 1 Page 39
E52 1584260 Cushion rubber 緩衝ゴム NE41013-4-230 L=230 1 Page 38
E54 1267060 Packing for prevention of air bypass バイパス防止用パッキン 4P011733-1 2 Page 39
E55 1267077 Packing for prevention of vibration CA前板ビビリ防止パッキン 4P050050-1 2 Page 24
E57 1267091 Wiring protection bush 配線保護ブッシュ 4P023920-1 BLACK 2 Page 30
E60 1267123 Thermal insulation tube piping 断熱筒配管緩衝材 4P011309-1 4 Page 37,38
E61 1584400 EV outlet pipe insulation tube 膨張弁出口配管防露筒 3P116142-1 1 Page 40
E63 1267154 Insulation tube evaporater header 蒸発器ヘッダー防露筒 4P073525-1 1 Page 40
E64 1267161 Cushion material suction pipe(1) 吸入配管緩衝材(1) 3P073468-1 1 Page 40
E65 1267178 Cushion material suction pipe(2) 吸入配管緩衝材(2) 3P073468-2 1 Page 40
E66 1267224 Cushion material suction pipe(3) 吸入配管緩衝材(3) 3P073468-3 1 Page 40
E67 1584378 Cushion material suction pipe 吸入配管緩衝材 4P140007-1 1 Page 40
E69 1267255 Thermal insulation tube 断熱筒(吸入弁・庫外側) 4P081186-1 1 Page 40
E70 1267262 Thermal insulation tube 断熱筒(圧縮機根元・吸入弁) 4P081187-1 1 Page 40
E72 1267286 Thermal insulation tube 断熱筒配管緩衝材 4P011309-3 1 Page 38
E73 1267293 Thermal insulation tube 断熱筒配管緩衝材 4P011309-4 2 Page 36
E82 1267370 Rubber bush ゴムブッシュ R3713279-2 2 Page 36
E90 1448371 Mounting plate, RSV 吸入比例弁防熱材 2P079441-1 1 Page 40
E91 1448388 Sealing material 吸入フランジシール材 4P083248-1 1 Page 36
E95 1386992 Tube clamp, heat exchanger 管止め金,二重管熱交 4P103281-56 2 Page 38
E96 1497102 Corrosion tape 吸入フランジ防食テープ 4P105751-1 2 Page 36
E74 1497056 Tube cushion material 配管緩衝材 4PA50421-2 1 Page 37
E76 1267325 Thermal insulation tube(drain outlet) 断熱筒(ドレン入口管防露筒) 4P067126-1 1 Page 40
E77 1485921 Thermal insulation tube(heat ex. inlet) 断熱筒(熱交入口管防露筒) 4P117089-1 1 Page 40
E78 1267349 Tube cushion material 配管緩衝材 4PA50427-1 1 Page 38
E79 0024640 Rubber bush ゴムブッシュ R3713279-3 5 Page 36
E80 1267356 Rubber bush ゴムブッシュ R3713279-4 2 Page 36
E81 0024640 Rubber bush ゴムブッシュ R3713279-3 3 Page 38
E83 1549825 U-packing U字形パッキン NA40014-4-170 L=170 1 Page 36
E84 B 1267394 Heat shrinkable tube 熱収縮チューブ 4PA60531-2 2 Page 37
E85 1549832 U-packing U字形パッキン NA40014-4-120 1 Page 36
E86 B 1270453 Heat shrinkable tube 熱収縮チューブ 4P075241-1 1 Page 37
E87 1497070 Insulation tape 不乾性形断熱テープ 3SA90101-3-KA 3 Page 36
E88 1494925 Protection plate, solenoid valve 保護板 4P093386-1 1 Page 37
E89 1270484 Mounting plate, solenoid valve 取付板 4P082208-1 1 Page 37
E92 1381012 Protection rubber 保護ゴム 4PA43128-1 4 Page 37
E93 1381029 Thermal insulation tube レヒートコイル出入口管防露筒 4P102857-1 2 Page 40
E94 1386985 Tube clamp, heat exchanger 管止め金,二重管熱交 4P103281-51 1 Page 38
![Page 44: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/44.jpg)
Other parts(Pipe clamp, sealing and insulation material etc.)その他部品(配管固定具、シール材、防熱材等)
43
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REFER PAGE
参照ページ
E97 1584277 Rubber bush ゴムブッシュ(膜付) 4P145364-1 1 Page 38
E98 1267356 Rubber bush ゴムブッシュ R3713279-4 1 Page 38
![Page 45: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/45.jpg)
Control boxコントローラボックス
F7-2F7-1F7-9
F7-3
F16-1
F16-2
F7-8
F7-4F7-7
F61F7-5
F7-6
F4
F18
F30
F27
F59
F23
F24
F22
F58F17
F33
F46F25
F57
F39
F7
44
![Page 46: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/46.jpg)
Control boxコントローラボックス
F34-1
F34-7
F34 F34-3
F34-2
F34-4
F70-2
F70F70-1
F70-3
F70-1
F34-1
F19
F20
F28
F71
F6
F32
F3
F42F62
F72
F69
F68
F66 F48
F36
F64F63
F65
F67
F29
F26
F34-8-1
F34-8
F34-11 F44
F13
F45
F34-12 F34-13
F34-14
F34-10
F31-1
F34-5
F34-6
F34-9
F31
F38
F37
F35
F40
F49F50
F39
F36
45
![Page 47: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/47.jpg)
Control boxコントローラボックス
46
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
F3 1136407 Hinge(recorder/box cover) 平蝶番(レコーダボックス蓋) 4P021346-1 2
F4 1136414 Patch plate nut 当板ナット 4P044898-2 2
F6 1381050 Control box welding ass'y C.BOX溶接組立品 2P098553-2 1
F7 C 1381067 Control box cover ass'y コントロールボックス蓋組立品 2P101874-1 1 Refer to Page 60
F7-1 1136407 Hinge(recorder/box cover) 平蝶番(レコーダボックス蓋) 4P021346-1 2
F7-2 1136414 Patch plate nut 当板ナット 4P044898-2 2
F7-3 0907093 Roller, quick lock lever ワンタッチ金具用ローラ 4PA51277-1 1
F7-4 1381074 Control box cover welding ass'y コントロールボックス蓋溶接組立品 3P101873-2 1
F7-5 1267457 Operation display cover 操作表示カバー 3P078251-1 t1.0 1
F7-6 1010815 Display board 表示基板 2P010368-2 EC9755-2 1
F7-7 1381081 Rubber gasket ゴムガスケット(C.BOX蓋) 4P085198-1 1 Refer to Page 60
F7-8 A 1295553 Control panel(with sheet key) コントロールパネル(シートキー付) 3P085319-1 1
F7-9 1128949 Packing パッキン(樹脂パネル) 3P030317-1 1
F20 1381106 Fixing plate PC port パソコンポート固定板 4P101826-1 1
F28 C 1141144 Contactor, receptacle コンタクタ、レセプタクル用 3P010806-1 HD10 3
F29 1381137 Cover ass'y, PC port パソコンポートカバー組立品 3P010743-2 1
F30 A 0954633 PT/CT board PT/CTボード 2P010906-3 1
F31 A 1256116 Terminal strip boaed 端子台基板 2P078284-1 1
F33 A 0329679 Reverse phase protector 逆相保護装置(RPP) 3SA42153-1 346-440V 1
F34 A 1584284 Controller ass'y コントローラ組立品 3P101756-7 1
F13 1136539 Clamp クランプ金具 4P015574-2 1
F16-1 0907062 Seal washer シール座金(ボンテッド座金) 4PA21941-5 10
F16-2 1267488 Pan head machine screw アプセット小ネジ 4P067677-1 M5×16 10
F17 1387197 Mounting plate welding ass'y 機器取付板(1) 2P095432-1 1
F18 1267503 Blind plate(2) 機器取付板(2) 2P078296-1 t1.2 1
F19 1381098 Mounting plate, terminal boad 端子台基板取付板 3P090389-1 1
F22 A 1198931 Magnetic contactor(for Fans) 電磁接触器(ファン用) 3P055568-1 24V PAK-6J31C 3 EFH,EFL,CFC
F23 A 1241493 Magnetic contactor(Phase correction contactor) 相順切換電磁接触器(PCC) 3P071508-3 24V RSK-35J 1 PCC1,2
F24 A 1198917 Magnetic contactor(Compressor) 電磁接触器(圧縮機) 3P055566-1 24V PAK35J-S536 1 CC
F25 A 1562796 Low frequency transfoemer 低周波変圧器 3P139293-1 1
F26 C 1381113 PC port connector パソコンポートコネクタ 3P073218-1 1
F27 A 1381120 Circuit breaker(CB) ノーフェーズブレーカ(CB) 3P093326-1 30A 1 NF1
F34-6 1099957 Support color, PCB プリント基板サポートカラー MI49531-13 14
F31-1 A 0030652 Fuse, controller 制御用ヒューズ 4SA42006-4 250V 10A 6
F34-1 A 1581379 CPU board ass'y プリント基板ASSY 2P065387-16 1
F34-2 A 1378751 I/O board I/Oボード 2P010367-2 1
F34-3 1381151 Bottom plate, controller コントローラ底板 2P098577-1 t1.2 1
F32 1381144 Humidity sensor mounting plate 湿度センサ取付板 4P010921-1 1
F34-4 B 1381168 Controller cover 蓋(コントローラ) 2P099967-1 t1.2 1
F34-5 1099940 Support bushing, PCB プリント基板サポートブッシュ MI49531-11 14
![Page 48: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/48.jpg)
Control boxコントローラボックス
47
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
F34-7 1267572 Rubber transistor 放熱用ゴムトランジスタ 4P005330-1 2
F34-8 A 1250783 PC board for suction modulating valve プリント基板ASSY(吸入制御弁用) 3P065441-1 EC0058 1
F34-9 1267596 Locking wire saddle ロッキングワイヤサドル 4P015570-2 LWS 3
F34-10 1267604 Flat cable clamp フラットケーブルクランプスナップタイプ 4P015573-1 1
F34-11 1136539 Clamp クランプ金具 4P015574-2 1
F34-12 1267611 Speed bolt スピードボルト(M6) 4P048680-3 M6×20(S) 2
F34-13 860005 Washer, speed bolt スピードボルト用座金 R4713334 4
F34-14 840002 Drop out prevention washer 脱落防止座金 R4718607-6 2
F35 1267628 Wire(wire ground) 電線(電線グランド) 4P067662-1 1
F36 1267635 Wire(wire ground) 電線(電線グランド) 4P067663-1 4
F37 1267642 Flexible tube connector フレキシブル管用コネクタ 4P010926-6 2
F38 1267659 Flexible wire tube フレキシブル電線管 3P010927-62 2
F61 1295623 Fixtture(instruction ring) 固定具(インストラクションリング) 4P064698-1 1
F62 1381175 PC board spacer サーキットボードスペーサ 4P000347-1 4
F63 1295630 Lever ワンタッチ金具 4P085171-1 1
F72 A 0927770 Humidty sensor (HUS) 湿度センサー 3PA61738-1 1
F39 1267666 Quick fastener クイックファスナー 4P064642-1 2
F40 860015 Universal nut 自在ナット R4713188-1 2
F42 833302 Nylon nut ナイロンナット R4716460-1 M4 4
F44 1099940 Support bushing, PCB プリント基板サポートブッシュ MI49531-11 7
F45 1099957 Support color, PCB プリント基板サポートカラー MI49531-13 7
F46 981616 Locking card spacer ロッキングカードスペーサー R3428091-3 KGLS-8S 4
F48 1326820 Packing, control box front panel パッキン(コントロールボックス前板) 4P085513-1 1
F49 1136539 Clamp クランプ金具 4P015574-2 2
F50 1267712 Clamp クランプ金具 3P049495-1 1
F57 1549894 Set plate(PT/CT board) 機器取付板(PT/CTボード) 3P126713-1 1
F58 1267781 Mounting plate, elect components 電装品取付板 4P064227-1 t=1.2 1
F59 1549902 Set plate(breaker) 機器取付板(ブレーカ) 3P126712-1 1
F34-8-1 A 670223 Fuse, controller 制御用ヒューズ 4SA42006-3 250V 5A 1
F64 1295647 Fixing plate for lever ワンタッチ金具取付板 4P085164-1 1
F67 833301 Nut ナイロンナット R4716460-3 M6 3
F68 1562859 Mounting plate, cover 機器カバー取付板 4P095433-1 1
F70-1 1381182 P.C.B Ass'y 充電P板組立品 2P103790-1-KA 1
F65 0907125 Sealed sheet 絶縁シート(ワンタッチ金具) 4PA52417-1 t0.075±0.01 1
F66 0907132 Sealed sheet 絶縁シート(ワンタッチ金具) 4PA52417-2 t0.075±0.01 1
F70 1378162 Chargable battery ass'y 充電器組立品 2P103790-1 1
F69 1378441 Stainless rivet ステンレスリベット 4P057425-2 2
F70-2 1381207 Chargable battery チャージャブルバッテリー 2P103790-1-KI 1
F70-3 1381214 Battery holder 電池ホルダー 2P103790-1-KU 1
F71 1381221 Seal pin 平行ピン 3P040139-1 2
![Page 49: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/49.jpg)
Parts related with name plate銘板関連
G23
G1 G2
G15
G21G12
G15
G10
G7G24G22
G5
G4
G3
G25 G26,G27,G29
G20G19
矢視B(VIEW B)断面A-A(SECTION A-A)
ケーシング後板(Casing rear plate)
48
![Page 50: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/50.jpg)
Parts related with name plate銘板関連
49
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
G1 1584291 Name plate, ventilator 換気口銘板 4P146327-1 English 1
G2 1267952 Name plate, ventilator arrow ベンチレータ矢印銘板 4P018502-1 1
G3 1557042 Name plate, operation 操作銘板 1P136900-1 English 1
G4 1306530 Name plate, brand name 意匠銘板 4P085985-1 English 1
G5 1381339 Name plate, unit performance 機械銘板 3P066702-1 English 1
G10 1178843 Name plate, refrigerant 冷媒銘板 3P009750-1 1
G12 1381346 Name plate, return 指示銘板(RETURN銘板) 4P103582-1 1
G15 1381360 Name plate, solenoid valves 電磁弁配置銘板 4P103583-1 English 1
G19 1181267 Caution label, high voltage 高電圧注意銘板 4P010095-1 English 1
G20 1584309 Name plate, wiring diagram 配線図銘板 2D047172-1 1
G21 0345587 Name plate, arrow 矢印銘板 YA41011-1 1
G22 1584316 Name plate, warranty period 保証期間銘板 4P146577-1 1
G23 1381391 Name plate, USDA USDA銘板 3P074006-1 1
G24 1381409 Caution label, refrigerant recovery フロン回収・破力法 3P086874-1 1
G25 1381416 Operation name plate, emergency エマジェンシー銘板 3P069655-1 1
G26 1372498 Instruction card, emergency & Service インストラクションカード(エマージェンシー&サービス) 3P092354-1 1
G27 1584323 Instruction card, basic operation インストラクションカード(基本操作) 3P146326-1 1
G29 1584330 Instruction card(Intial setting) インストラクションカード(初期設定) 3P146678-1 1
G7 1381423 Name plate, supply 指示銘板(SUPPLY銘板) 4P103582-2 1
![Page 51: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/51.jpg)
Parts related with option 1 – USDAオプション関連部品1 – USDA関連
I2
I1
I9
I3
I3
I3
I4
I4
I4
I3
I4
I6 I5
I7
I8
50
![Page 52: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/52.jpg)
51
Parts related with option 1 – USDAオプション関連部品1 – USDA関連
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
I1 1497948 Mounting plate ass'y receptacles 本体組立品(レセプタクル) 3P094639-1 1
I2 1381454 Mounting plate(Receptacle) 取付板(レセプタクル) 3P094638-1 1
I3 0991531 PC port connector パソコンポートコネクター 3P010803-1 4
I4 1267541 Cover ass'y, PC port キャップ 3P010743-1 4
I5 1381113 Receptacle connector レセプタクルコネクター 3P073218-1 1
I6 1381137 Cap, receptacle キャップ 3P010743-2 1
I7 1141144 Contactor, receptacle コンタクタ、レセプタクル用 3P010806-1 11
I8 1381221 Seal pin 平行ピン 3P040139-1 6
I9 1381461 Cover, receptacles レセプタクルカバー 3P094640-1 1
![Page 53: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/53.jpg)
Parts related with option 2 – MODEMオプション関連部品2 –モデム
MODEM モデム
Supply by customer客先支給�
J1
J2
J5
J6
J4
J3
J8J7
52
![Page 54: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/54.jpg)
Parts related with option 2 – MODEMオプション関連部品2 –モデム
53
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
J1 0954640 Noise filter ノイズフィルタ 2PA51273-1 ZAC2206-11 1
J2 1448410 Mounting olate(modem) 取付板(モデム) 4P081133-1 t1.6 1
J3 1267736 Connector for MODEM モデム用コネクタ 3P012038-3 BLA3 1
J4 1267743 Connector for MODEM モデム用コネクタ 3P010371-7 1
J5 1267750 Connector for MODEM モデム用コネクタ 3P012038-7 BLA7 1
J6 0468839 Noise filter(for modem) ノイズフィルター(モデム用) 3EA76001-1 1
J7 1267767 CR rubber CRゴム 4P027629-1 1
J8 1344781 Vinyl bag ビニール袋 RI40021-5 2
![Page 55: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/55.jpg)
Parts related with option 3 – Othersオプション関連部品3 –その他
K2
K5
K3
K4
K1
54
1.Indoor fan guard1.庫内ファンガード
2.Evaporator coil2.蒸発器コイル組立品
K6
![Page 56: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/56.jpg)
Parts related with option 3 – Othersオプション関連部品3 –その他
55
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
K1 1381478 Fan cover 庫内ファンカバー 2P094862-1 1
K2 1381485 Fixing plate, fan cover ファンカバー固定板 4P103482-1 1
K3 1381492 Stay, fan cover 庫内ファンカバーステー 3P094786-1 1
K4 1381500 Fixture, fan cover(left) 固定具(網/左) 3P098695-1 1
K5 1381517 Fixture, fan cover(right) 固定具(網/右) 3P098695-2 1
K6 1380691 Evaporator ass'y 蒸発器組立品 2P071832-1 1
![Page 57: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/57.jpg)
Parts related with option 4 – TRANS – FLESHオプション関連部品4 –トランス・フレッシュ
E97
A
A2,A3 cables
E98
A2,A3cables
L2
A2 cable
56
A内部詳細 ( Detail of inside A )
![Page 58: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/58.jpg)
Parts related with TRANS – FLESHトランス・フレッシュ関連部品
A2 cable ass'y
A3 cable ass'y
57
L1詳細 ( L1 detail )
L2詳細 ( L2 detail )
NO.
符号INDEX
PARTS NO.
部品番号PARTS NAME 部品名称
DWG. NO.
図面番号
TYPE SPECIFICATION
形式 仕様
QTY/UNIT1台当たりの所要数
REMARKS
備考
L1 1584347 A2 cable ass'y A2ケーブル組立品+防水キャップ 3P145289-1 1
L2 1584354 A3 cable ass'y A3ケーブル組立品+防水キャップ仕様 3P145293-1 1
E97 1584277 Rubber bush ゴムブッシュ(膜付) 4P145364-1 1 Refer to Page 38,56
E98 1267356 Rubber bush ゴムブッシュ R3713279-4 1 Refer to Page 38,56
A38 1584152 Single purge port ass'y シングルパージポート組立品 3P039625-1 1 Refer to Page 25
![Page 59: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/59.jpg)
List of size for standard pipe clamp配管固定具サイズ表
58
1.Resin clamp1.樹脂バンド
H
(外穴)�
(OUTER HOLE)
C
φ
D±1.0
H
(内穴)(外穴)
(INNER HOLE)(OUTER HOLE)� φD±
1.0
C
H(INTERMEDIATE HOLE)
(内穴)(中穴)(外穴)�(INNER HOLE) (OUTER HOLE)�
φD±
1.0
C
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
DWG NO.
図面番号
SIZE サイズ QTY
使用個数D C H
E9 0118273 Resin clamp 樹脂バンド NE41015-2 6.8 15.8 4.8 5
E11 0944528 Resin clamp 樹脂バンド NE41015-7 19.8 24.6 7.9 2
E10 1222764 Resin clamp 樹脂バンド NE41015-9 26.9 27.8 7.9 1
E12 0142492 Resin clamp 樹脂バンド NE41015-10 29.2 29.4 7.9 2
E13 1266788 Resin clamp 樹脂バンド NE41015-12 39.4 34.2 9.5 4
![Page 60: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/60.jpg)
2.Tube clamp2.管止金
3.Cushion rubber for pipe clamp3.管止金用緩衝ゴム
List of size for standard pipe clamp配管固定具サイズ表
59
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
DWG NO.
図面番号
REMARKS
備考
E35 1266911 Cushion rubber 管止金用緩衝ゴム NE41013-3-300
Cut to suit pipe size.
配管サイズに合わせて切
って使用のこと
L
L=300 (or 230)
SIZE L :NE41013-3 L=22NE41013-4 L=42
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
DWG NO.
図面番号
SIZE サイズ QTY
使用個数D C H
E15 0782775 Tube clamp 管止金 NE31016-51 10 20 3 5
E16 1584208 Tube clamp, Nylon Coating 管止金、ナイロンコーティング 4P143802-52 12 21 3 2
E17 1584215 Tube clamp, Nylon Coating 管止金、ナイロンコーティング 4P143802-51 10 20 3 6
E21 1584239 Tube clamp, Nylon Coating 管止金、ナイロンコーティング 4P143802-71 6.4 20 1 7
H
φD
7
C
15
2-φ5.5穴
E18 1584222 Tube clamp, Nylon Coating 管止金、ナイロンコーティング 4P143802-54 16 23 4 1
E19 0700090 Tube clamp 管止金 NE31016-54 16 23 4 1
E20 0016290 Tube clamp 管止金 NE31016-56 20 25 5 1
E27 1266858 Tube clamp 管止金 NE31016-59 26 28 5 1
E29 1584246 Tube clamp, Nylon Coating 管止金、ナイロンコーティング 4P143802-59 26 28 5 1
E6 1270439 Tube clamp 管止金 NE31016-61 30 30 5 2
'QTY
使用個数
1
E85 Cushion rubber 管止金用緩衝ゴム NE41013-4-230 1
Cut to suit pipe size.
配管サイズに合わせて切
って使用のこと
![Page 61: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/61.jpg)
60
Notes for ordering spare parts部品発注の際の注意事項
1.Parts recommended to be ordered together with packing,gasket, sealing material and name plate
1.発注の際にパッキングやシール材、銘板等の同時発注を推奨する部品
For ordering following spare parts, we recommend that you order the followingpacking, gasket, sealing material and name plate together at the same time.上記のサービス扉やボックスカバーを発注の際には、下記のパッキングを同時に発注することをおすすめします。
(1)Service door(1)サービス扉
(2)Control box cover(2)コントロールボックスカバー
※Rubber gasket, sheet key is attacked to controlbox cover ass'y.
※ゴムガスケットとシートキーはコントロールボックス組立品に付属しています。
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
REMARKS
備考
A4 0980423 Access panel ass'y サービス扉組立品
(Without cushion and
sealing material)
(クッション材、シール材なし)
A6 1196113 Sealing material シール材
F7
G3
G20NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
DWG NO.
図面番号
F7 1381067Control box cover
ass'yコントロールボッ
クスフタ組立品2P101874-1
G20 1584309Name plate,
wiring diagram電気配線図銘板 2D047172-1
DWG NO.
図面番号
1P006678-1
A5 1266207 Cushion material クッション材 3P033608-1
3P001640-2
A4A5
A6
G3 1557042Name plate,
operation操作銘板 1P136900-1
![Page 62: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/62.jpg)
61
Notes for ordering spare parts部品発注の際の注意事項
(4)Ventilation cover(4)換気口蓋
(5)Front plate (CA)(5)前板(CA)
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
REMARKS
備考
A19 Ventilation cover 換気口蓋
A19
A20
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
DWG NO.
図面番号
A15 1270338 Front plate (CA) 前板(CA) 2P061345-1
G10 1178843Name plate,
refrigerant冷媒銘板 3P009750-1
G4 1306530Name plate,
brond name意匠銘板 4P085985-1
A15
G4
G10R 1 3 4 a
DWG NO.
図面番号
3P067053-1
A20 1266221Sealing material
(access panel)シール材
(換気口)4P016185-1
Required
2 pcs.
![Page 63: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/63.jpg)
62
Notes for ordering spare parts部品発注の際の注意事項
2.Order for motorized valve, solenoid valve and pressureregulating valve
2.電動弁・電磁弁・圧力調整弁の発注
Refer to the following table for the name, main body, solenoid coil and ass'y ofsolenoid valves etc. applied to this model.この機種に使用されている電磁弁等の名称と本体・コイル・組立品は下記のとおりです。
Note 1 :Refer Page 6 for detail parts of suction modulating valve.注1 :SMV(吸入比例弁)の詳細部品はP.26を参照ください。
Body/Coil
本体/コイルPARTS NAME 部品名称
1.EV本体 Body Electronic expansion valve body 電子膨張弁本体
コイル Coil Electronic expansion valve coil 電子膨張弁コイル
2.HSV本体 Body Hot gas solenoid valve body ホットガス電磁弁本体
コイル Coil Hot gas solenoid valve coil ホットガス電磁弁コイル ○
NO.
符号
PARTS NO.
部品番号
B7-3 1256495
B20 1381430
B7-4 0944566
B7-5 0955287
3.DSV本体 Body B7-4 0944566 Defrost bypass solenoid valve body デフロストバイパス電磁弁本体
コイル Coil B7-5 0955287 Defrost bypass solenoid valve coil デフロストバイパス電磁弁コイル ○
5.RSV本体 Body B7-4 0944566 Reheat coil bypass solenoid valve body レヒートコイルバイパス電磁弁本体
コイル Coil B7-5 0955287 Reheat coil bypass solenoid valve coil レヒートコイルバイパス電磁弁コイル ○
6.ESV本体 Body B7-6 0088738 Economizer solenoid valve body エコノマイザー電磁弁本体
コイル Coil B7-7 0955287 Economizer solenoid valve coil エコノマイザー電磁弁コイル ○
7.ISV本体 Body B7-6 0088738 Injection solenoid valve body インジェクション電磁弁本体
コイル Coil B7-7 0955287 Injection solenoid valve coil インジェクション電磁弁コイル ○
10.DPR 組立品 Ass'y B3-4 1241361Discharge pressure
regulating valve吐出圧力調整弁
DWG NO.
図面番号
Common Parts
共通部品
2SA50010-2-KU
2P010454-2
R3305118-1 ○
3P010453-1
R3305118-1 ○
3P010453-1
R3305118-1 ○
3P010453-1
R3305099-1-KI ○
3P010453-1
R3305099-1-KI ○
3P010453-1
3P074558-1
8.LSV本体 Body B4-5 0944566 Liquid solenoid valve body 液電磁弁本体 R3305118-1 ○
コイル Coil B4-6 0955287 Liquid solenoid valve coil 液電磁弁コイル 3P010453-1 ○
9.SMV 組立品 Ass'y B8-1 1254538 Suction modulating Valve 吸入比例弁組立品 2P078385-1Note 1
注1
NE
V-8
03D
XF
NE
V-2
02D
XF
NEV-
MOA
B507
C1
4.BSV本体 Body B7-4 0944566 Gas bypass solenoid valve body ガスバイパス電磁弁本体 R3305118-1 ○
コイル Coil B7-5 0955287 Gas bypass solenoid valve coil ガスバイパス電磁弁コイル 3P010453-1 ○
![Page 64: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/64.jpg)
Notes for ordering spare parts部品発注の際の注意事項
3.Order for pressure trasducer3.圧力センサーの発注
Refer to the following table for the pressure transducer applied to this model.For ordering pressure transducer, we recommend that you order the following bestshrinkable tube together at the same time.この機種に使用している圧力センサーは下記の通りです。圧力センサー発注の際は、下記の熱収縮チューブを同時に発注することをおすすめします。
63
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
REMARKS
備考
B15 0797241 Low pressure transducer 低圧圧力センサー
E84 1267394Heat shrinkable
tube熱収縮チューブ
Must be applied
when replacing
above sensors.
上記圧力センサー交換時使用の事。
B18 1011065 Cable, low pressure transducer 低圧圧力センサー用ケーブル
呼称名
LPT
DWG NO.
図面番号
4PA60524-1
3P008835-2
4PA60531-2
HPT B16 0797234 High pressure transducer 高圧圧力センサー 4PA60522-1
B17 1011058 Cable, high pressure transducer 高圧圧力センサー用ケーブル 3P008835-1
TYPE
形式
SPCH01
SPCL02
![Page 65: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/65.jpg)
64
Notes for ordering spare parts部品発注の際の注意事項
4.Order for temperature sensor4.温度センサーの発注
Refer to the following table for temperature sensors applied to this model.この機種に使用されている温度センサーは下記の通りです。
1210 ST9701-
Length
LOT表示�型番表示�Type No.Lot marks
5Y01 ST9503-1-ABA B
LOT
Length
表示�型番表示�Type No.Lot marks
7828 ST9703-1
Length
LOT表示�型番表示�Type No.Lot marks
NO.
符号
PARTS
NO.
部品番号
PARTS NAME 部品名称
TEMPORALY
EXCHANGABILITY
緊急時互換性呼称
DWG. NO.
図番
※1LOCATION
取付場所
TYPE
形式
WIRE COLOR
配線色LENGTH
全長mmA B
1. SS C24 1375310Supply air
temp. sensor
吹出空気温度センサー
3PA61769-11 ST9503-11green
緑
-
-4700
Indoor A
庫内A○
2. DSS C25 1375327Data recorder supply
air temp. sensor
データレコーダ吹出空気温度センサー
3PA61769-12 ST9503-12green
緑Red
赤4700
Indoor A
庫内A○
3. RS C26 1375334Return air temp.
sensor
吸込空気温度センサー
3PA61769-13 ST9503-13Blue
青
-
-6700
Indoor B
庫内B○
4. DRS C27 1375341Data recorder return
air temp. sensor
データレコーダ吸込空気温度センサー
3PA61769-14 ST9503-14Blue
青Red
赤6700
Indoor B
庫内B○
5. EIS D4 1562828Evaporator inlet
temp. sensor
蒸発器入口温度センサー
3P012118-2 ST9703-2-
-
Black
黒2500
Indoor EVP.
庫内蒸発器
6. EOS D5 1562835Evaporator outlet
temp. sensor
蒸発器出口温度センサー
3PA61769-15 ST9503-15Yellow
黄
-
-2600
Indoor EVP.
庫内蒸発器○
7. DCHS B11 0983321Discharge pipe
temp. sensor
吐出管温度センサー
3SA48009-10 ST9701-10 - 2800Outdoor
庫外
8. AMBS B12 0798321Ambient
air temp. sensor
外気温度センサー
3PA61769-6 ST9503-6-
-
-
-3200
Outdoor
庫外○
9. SGS B13 0983338Compressor suction
gas temp. sensor
圧縮機吸入ガス温度センサー
3PA61769-9 ST9503-9White
白
-
-3200
Outdoor
庫外○
※Operating temp. range ー30~+15℃使用温度範囲 ー30~+15℃ ※1 Location 取付場所
Indoor A : Indoor supply air side Indoor B : Indoor return air side
庫内A : 庫内吹出空気側 庫内B : 庫内吸込空気側
※Operating temp. range ー30~+150℃使用温度範囲 ー30~+150℃
※Operating temp. range ー30~+70℃使用温度範囲 ー30~+70℃
![Page 66: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/66.jpg)
65
Measuring and adjusting tools測定調整用工具
1.Tools for emergency operation1.緊急運転用工具
(See Service Manual for application.)(使用方法はサービスマニュアルを参照ください。)
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
ILLUSTLATION
姿図
- 1270530E m e r g e n c y
magnet
エマージェンシーマグネット
- 1080263Emergency coil
cap
エマージェンシーコイルキャップ
DWG NO.
図面番号
USE
用途
3P017370-1
For electronic
expansion
valve
電子膨張弁用
2P078385-2
Suction
modulating
valve
吸入比例弁用
UPSIDE
→OPEN
DOWNSIDE
![Page 67: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/67.jpg)
Measuring and adjusting tools測定調整用工具
2.Personal computer cable (for DCCS)2.パソコンケーブル(DCCS用)
The following parts are connector cables required to exchange information betweenthe refrigeration unit and personal computer. The table below describes parts requiredto apply to Model LXE-C, -D, and -E new model.下記の部品は冷凍ユニットとパソコンの情報交換に必要なコネクター、ケーブル類です。LXE-C型、 D型、及び新機種E型対応に必要な部品を掲載しています。
[TYPE A]タイプALXE10C LXE10CLXE10CA LXE10CALXE10D for MOL MOL用LXE10D
(Receptacle) (レセプタクル)RS232C (Female) RS232C(メス)on the controller コントローラー側
[TYPE B]タイプB
LXE10D LXE10DLXE10E LXE10E
(Receptacle) (レセプタクル)Water proof type コンテナ冷凍機on the unit ユニットの防水型
(1)Parts No.(1)部品番号
66
w 0.3m q 1.5me
r or tr 2.0mt 1.5m
eq 1.5m
NO.
符号
PARTS NO.
部品番号PARTS NAME 部品名称
REMARKS
備考
5 1384509 Connection cable (5 Pins) 接続ケーブル(5ピン)For LXE10E-A14,A15
LXE10E-A14、A15用
1Local supply
市販品Connection cable (reverse)
接続ケーブル(リバース)
RS232C reverse (cross) type
RS232Cリバース(クロス)型
2 9993324 Connection cable 接続ケーブル
3Local supply
市販品
Adapter
(gender changer)
アダプター(ジェンダーチェンジャー)
D-sub 9P, Male-Male
Dサブ9ピン、オス-オス
4 1087149 Connection cable (3 Pins) 接続ケーブル(3ピン)LXE10E-A Standard
LXE10E-A標準
![Page 68: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/68.jpg)
Measuring and adjusting tools測定調整用工具
67
NO.
符号
Illustlation
姿図
Internal Wiring
内部配線
1
2
5
12345678
Frameフレーム�
Frameフレーム�
12345678
RS232CFemaleメス�
RS232CFemaleメス�
123456789
ABC
Daikinmade
ダイキン製�
RS232CFemaleメス�
RedWhite
Black
Red 赤�
White 白�Black 黒�
ABCDE
12345678
Daikinmade
ダイキン製�
RS232CFemaleメス�
Frameフレーム�
4
Red 赤�
White 白�Black 黒�
ABC
12345678
Daikinmade
ダイキン製�
RS232CFemaleメス�
Frameフレーム�
3
![Page 69: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/69.jpg)
MEMO
![Page 70: LXE10E-A27 - · PDF file11 Covered Models Regarding the features and operation of the unit, this service manual describes the items which are different from those of the service](https://reader031.fdocuments.us/reader031/viewer/2022012307/5a9dc5eb7f8b9a85318c6655/html5/thumbnails/70.jpg)
TR04-05
(2005.02.00050)NK
Head Office. Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, 530-8323 Japan.
Tel: 06-6373-4338
Fax: 06-6373-7297
Tokyo Office. JR Shinagawa East Bldg., 10F 18-1, Konan 2-chome, Minato-ku Tokyo, 108-0075 Japan.
Tel: 03-6716-0420
Fax: 03-6716-0230
TR04-05
Marine type Container Refrigeration Unit
LXE10E-A27
Service Manual・Parts List
Optional Functions