LUCX facility introduction: present status and future plans
description
Transcript of LUCX facility introduction: present status and future plans
LUCX FACILITY INTRODUCTION: PRESENT STATUS AND FUTURE
PLANS
A. AryshevOn behalf of QB group and
THz collaboration
Mini-workshop for advanced THz and Compton X-ray generation
18 – 19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
2
Outline• THz project overview
– LUCX activity – LUCX Projects Overview– THz program
• LUCX Laser system • LUCX 2012 upgrade
– LUCX operation modes– e-beam optics– THz program vacuum system, manipulator
• Measurement setup and DAQ• Schedule & Conclusion• Resources
19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
3
LUCX: international collaboration• Initially the machine was built as a RF Gun test bench in 2005• In 2006 (RF Gun + Accelerating structure) it was extended to produce
~40MeV e-beam and Compton experiment started• 2009 a new 1.6 cell RF-Gun was made, installed and commissioned.• 2011 RF-Gun replacement -> 3.6 cell • From 2009 CDR experiment started• From 2012 THz program was started
• KEK, Waseda University, Osaka University, Tomsk Polytechnic University, Royal Holloway University of London.
• Kharkov Institute of Physics and Technology, Oxford, Moscow Engineering Physics Institute.
19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
4
Accelerator operation
19 March 2013
LUCX Activities Overview
Projects Machine studies
1. Beam dynamics2. Multibunch tuning3. Stabilization
Training Maintenance
1. Alignment2. Calibrations3. Debugging
General improvements and
upgrades
Ti – Sa lasersystem integration
ZEMAX and CST simulations
Documentation& publicity
Mini-workshop for advanced THz and Compton X-ray generation
519 March 2013
LUCX Projects Overview
Pulsed-laser Super-cavity R&D for compact X-ray
source
4-mirror planar optical super-
cavity
X-ray imaging
THz
CDR
Undulator study
CSPR
BLM
FSTB
fs buncher system
Multi-bunch train
Photo-cathode RF Gun and
accelerator R&D
Multi-cell Accelerating
cavities development
Project candidatesTHz imaging
Mini-workshop for advanced THz and Compton X-ray generation
619 March 2013
THz
prog
ram
Laser system (FSTB + Nd:YAG)
Establishment of FSTB infrastructure
FSTB startup, stable operation
Reliable and routine laser beam diagnostics
Buncher development
Ti:Sa 3rd harmonicSynchronization with
LUCX timing
Integration with LUCX control soft
Modification of LTL. Optical switch between
FSTB and Nd:YAG
Accelerator side
Vacuum systemmodification in a
course of 2012 LUCX upgrade
THz chamber and manipulator design and Manufacturing
Benchmarking, calibration
Installation into beamline
fs electron beam generation
Cs2Te Cathode response time study
Longitudinal beam size diagnostics
MeasurementSystem and DAQ
THz spectrum measurements
Shot-by-shot intensity Mechanical part of THz detection system DAQ & soft
!!!
!!!
!!!
- ≥ 50% completion
!!! – vast importance
LUCX activities key points• Accelerator
– Generation of a stable ps and fs electron beam – Reliable beam diagnostics – Ability to measure longitudinal beam profile– Beam dynamics simulation (with intension to make it on-line)– Control upgrade (Soft&Space)
• Laser system– Will be shown in a next talk by Dr. K. Lekomtsev
• THz Measurement system– Will be shown in a next talk by Dr. M. Shevelev
• Compton experiment– Covered by prof. J. Urakawa on March 18th
• CDR experiment– Covered by Dr. A. Aryshev on March 18th
19 March 2013
LUCX Facility
19 March 2013 Mini-workshop for advanced THz and Compton X-ray generation 8
FSTB
Nd:YAG
Modulator #0
KLY#0
LUCX accelerator tunnel
KLY#1
Modulator #1LUCX control room
Mini-workshop for advanced THz and Compton X-ray generation
9
LUCX “2012 UPGRADE”:THZ, 12-CELL BOOSTER
19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
10
LUCX “2012 upgrade”
19 March 2013
GV
GVTHz chamber
CDR Compton THz
Mini-workshop for advanced THz and Compton X-ray generation
11
LUCX “2012 upgrade”, e-optics
19 March 2013
“Compton optics”
THz Compton CDR
Mini-workshop for advanced THz and Compton X-ray generation
12
LUCX beam diagnostics• BPMs
– Well established Button BPM system• Profile monitors (Screens: OTR, “DMQ”)
– Require upgrade (CCDs, analysis) -> better emittance measurements• Beam Charge monitor
– Well established, FC and ICTs• Beam energy, energy spread
– Well established, but after 12-cell booster• Beam loss monitor
– So-called “plick” or a simple gamma detector – has to be installed• Longitudinal profiling
– Has to be developed. Candidates: Streak camera, Deflecting cavity.
19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
13
LUCX Control upgrade
• Control room re-arrangement to accommodate large collaboration groups
• Control PCs and display system upgrade• Control soft at present will be the same with the
slow upgrades in the future• FemtoSecondTestBench control and monitors will
be installed and included into the main LUCX control soft
• Well defined and documented API
19 March 2013
Mini-workshop for advanced THz and Compton X-ray generation
14
Resources
• THz program web:http://www-atf.kek.jp/thz/index.html
• LUCX wiki (documentation, e-log, etc.):http://atf.kek.jp/twiki/bin/view/LUCX/WebHome
• QB program web:http://kocbeam.kek.jp/
19 March 2013