LTE-eNB-SC-EN06.00-00
-
Upload
powei-chang -
Category
Documents
-
view
316 -
download
5
Transcript of LTE-eNB-SC-EN06.00-00
Ver.
2600-00FET7GAT 6.0
LTE eNB
System Counter Description_SLR 2.4
Ver.
2600-00FET7GAT 6.0
COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics
Co., Ltd.
TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective
companies.
This manual should be read and used as a guideline for properly installing and operating the product.
All reasonable care has been made to ensure that this document is accurate. If you have any comments on
this manual, please contact our documentation centre at the following address:
Address: Document & Training Center 3rd Floor Jeong-bo-tong-sin-dong. 129, Samsung-ro, Yeongtong-gu, Suwon-
si, Gyeonggi-do, Korea 443-742
Homepage: http://www.samsungdocs.com
© 2013 SAMSUNG Electronics Co., Ltd. All rights reserved.
Ver.
INTRODUCTION
© SAMSUNG Electronics Co., Ltd. page 3 of 427
2600-00FET7GAT 6.0
INTRODUCTION
Purpose
LTE eNB System Counter Description provides detailed information for each statisti
cal item for statistics data analysis.
Document Content and Organization
This manual consists of one Chapter.
Statistics Items
Provides the definition, index, statistic types and collection time for each statistics it
em.
Conventions
The following types of paragraphs contain special information that must be carefully
read and thoroughly understood. Such information may or may not be enclosed in
a rectangular box, separating it from the main text, but is always preceded by an
icon and/or a bold title.
NOTE
Indicates additional information as a reference.
Relevance
This manual applies to the following Samsung network software releases:
Technology Software Release
LTE SLR 2.4
Ver.
INTRODUCTION
© SAMSUNG Electronics Co., Ltd. page 4 of 427
2600-00FET7GAT 6.0
Related Document
Listed below is the entire document set of the product:
Document Describes…
Feature Description features across a Samsung telecommunications
network’s products.
Software Block Description software blocks across a Samsung telecommunications
network’s products.
Command Description commands across a Samsung telecommunications
network’s products.
Printout message Description printout messages across a Samsung
telecommunications network’s products.
Network Planning Manual network plans across a Samsung telecommunications
network’s products.
Optimisation Manual optimisation guidelines across a Samsung
telecommunications network’s products.
Product Description the product.
Dimensioning Manual dimensioning in the product.
System Parameter Description system parameters used in the product.
System Counter Description counters in the product.
Installation Manual the installation of the Product.
Commissioning and Integration Manual commissioning and integration of the product.
Operation Manual operation of the product.
Maintenance Manual maintenance of the product.
Hardware Inspection and Replacement
Manual
hardware inspection and replacement of the product.
EMS User Manual the Element Management System (EMS) from
Samsung.
Ver.
INTRODUCTION
© SAMSUNG Electronics Co., Ltd. page 5 of 427
2600-00FET7GAT 6.0
WEEE Symbol Information
This marking on the product, accessories or literature indicates that the product and
its electronic accessories (e.g. charger, headset, USB cable) should not be disposed
of with other household waste at the end of their working life. To prevent possible
harm to the environment or human health from uncontrolled waste disposal, please
separate these items from other types of waste and recycle them responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can take these items for
environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product and its electronic accessories should not be mixed with other commercial
wastes for disposal.
BATTERY Symbol Information
Correct disposal of batteries in this product
(Applicable in countries with separate collection systems.)
The marking on the battery, manual or packaging indicates that the battery in this product should
not be disposed of with other household waste. Where marked, the chemical symbols Hg, Cd or
Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC
Directive 2006/66.
The battery incorporated in this product is not user replaceable. For information on its
replacement, please contact your service provider. Do not attempt to remove the battery or
dispose it in a fire. Do not disassemble, crush, or puncture the battery. If you intend to discard the
product, the waste collection site will take the appropriate measures for the recycling and
treatment of the product, including the battery.
Ver.
INTRODUCTION
© SAMSUNG Electronics Co., Ltd. page 6 of 427
2600-00FET7GAT 6.0
Revision History
VERSION DATE OF ISSUE REMARKS
6.0 07. 2013. - Changed
3.3 RRC Connection Reestablishment
5.0 06. 2013. - Changed
3.7 RRC Connection Reestablishment Time
5.4 S1 Handover Out
24.6 MOBILITY
4.0 06. 2013. - Changed
24.3 RETAINABILITY (QCI)
3.0 05. 2013. - Granularity Formula field of each Statistics item is
added.
- Visible field of each Statistics item is added.
2.0 03. 2013. - Changed
18.1 MIMO performance
- Deleted
6 HO HRPD
8 HO 1XRTT
- Added
2.6 VPN Interface
6.3 UTRAN SRVCC
23.3 RETAINABILITY (QCI)
23.8 Connection Drop Rate
1.0 02. 2013. First Version
Ver.
TABLE OF CONTENTS
© SAMSUNG Electronics Co., Ltd. page 7 of 427
2600-00FET7GAT 6.0
TABLE OF CONTENTS
INTRODUCTION 3
Purpose ..................................................................................................................................................... 3
Document Content and Organization ...................................................................................................... 3
Conventions ............................................................................................................................................... 3
Relevance .................................................................................................................................................. 3
Related Document .................................................................................................................................... 4
WEEE Symbol Information ....................................................................................................................... 5
BATTERY Symbol Information ................................................................................................................. 5
Revision History ........................................................................................................................................ 6
Statistics Items 12
1 Resource Management ............................................................................................................13
1.1 Resource ..................................................................................................................................... 13
2 Packet Statistics ......................................................................................................................16
2.1 Ethernet Interface ....................................................................................................................... 16
2.2 Histogram .................................................................................................................................... 24
2.3 Air Mac UL/DL bytes (Kbytes) .................................................................................................... 26
2.4 Air RLC UL/DL bytes .................................................................................................................. 29
2.5 S-GW UL/DL packets ................................................................................................................. 33
2.6 VPN Interface .............................................................................................................................. 36
3 RRC .......................................................................................................................................37
3.1 RRC Connection Establishments .............................................................................................. 39
3.2 RRC Connection Reconfiguration ............................................................................................. 43
3.3 RRC Connection Reestablishment ............................................................................................ 45
3.4 RRC Connection Release .......................................................................................................... 49
3.5 RRC Connection number ........................................................................................................... 54
3.6 RRC Connection Setup Time..................................................................................................... 56
3.7 RRC Connection Reestablishment Time .................................................................................. 59
3.8 Call Drop ..................................................................................................................................... 62
4 ERAB .......................................................................................................................................65
4.1 E-RAB Setup .............................................................................................................................. 65
Ver.
TABLE OF CONTENTS
© SAMSUNG Electronics Co., Ltd. page 8 of 427
2600-00FET7GAT 6.0
4.2 E-RAB Setup Add ....................................................................................................................... 69
4.3 E-RAB Setup Time ..................................................................................................................... 73
4.4 eNB E-RAB Erase Request ....................................................................................................... 75
4.5 E-RAB Erase ............................................................................................................................... 78
4.6 E-RAB Modify ............................................................................................................................. 80
4.7 eNB E-RAB Release Request ................................................................................................... 84
4.8 E-RAB Release ........................................................................................................................... 86
4.9 E-RAB Activity (UE) .................................................................................................................... 88
4.10 E-RAB Activity (QCI) ................................................................................................................... 89
4.11 E-RAB Simultaneous Number ................................................................................................... 90
5 Handover (HO) EUTRAN ......................................................................................................... 91
5.1 Intra eNB Handover .................................................................................................................... 98
5.2 X2 Handover Out ...................................................................................................................... 103
5.3 X2 Handover In ......................................................................................................................... 109
5.4 S1 Handover Out ...................................................................................................................... 115
5.5 S1 Handover In ......................................................................................................................... 120
5.6 Handover Time (Average, Max) ............................................................................................... 125
5.7 Outgoing Intra-Frequency Handover ....................................................................................... 130
5.8 Outgoing Inter-frequency Handover with Measurement Gap ................................................ 135
5.9 Outgoing Inter-frequency Handover without Measurement Gap ........................................... 141
5.10 Outgoing Handover with DRX .................................................................................................. 148
5.11 Outgoing Handover without DRX............................................................................................. 152
6 HO UTRAN ............................................................................................................................. 157
6.1 Inter-RAT UTRAN PS Handover OUT .................................................................................... 160
6.2 Inter-RAT UTRAN PS Handover IN ......................................................................................... 164
6.3 UTRAN SRVCC ........................................................................................................................ 169
6.4 CS Fall Back (CSFB) PS Handover OUT ............................................................................... 172
6.5 CS FallBack (CSFB) without PS Handover Out (Redirection) ............................................... 177
6.6 PS Redirection UTRAN Out ..................................................................................................... 179
7 CSL ..................................................................................................................................... 180
7.1 Call Fail Report ......................................................................................................................... 180
8 MRO_RLF ............................................................................................................................... 213
8.1 MRO RLF Classification ........................................................................................................... 213
9 GTP ..................................................................................................................................... 215
9.1 GTP Sequence Number by QCI .............................................................................................. 215
9.2 GTP Sequence Number by eNB ............................................................................................. 216
9.3 GTP Forward Traffic ................................................................................................................. 218
10 SRB ..................................................................................................................................... 231
Ver.
TABLE OF CONTENTS
© SAMSUNG Electronics Co., Ltd. page 9 of 427
2600-00FET7GAT 6.0
10.1 Cell PDCP SDU bit-rate ........................................................................................................... 231
11 DRB .....................................................................................................................................233
11.1 Active UEs ................................................................................................................................. 233
11.2 Packet Delay ............................................................................................................................. 235
11.3 Packet Drop Rate ..................................................................................................................... 236
11.4 Packet Loss Rate (ppm) ........................................................................................................... 238
11.5 IP Latency measurements ....................................................................................................... 240
12 RRU .....................................................................................................................................241
12.1 DL/UL PRB Usage .................................................................................................................... 241
12.2 DL/UL Total PRB Usage ........................................................................................................... 243
12.3 Cell Unavailable Time ............................................................................................................... 247
13 S1SIG .....................................................................................................................................248
13.1 UE-associated logical S1-connection establishment .............................................................. 248
13.2 S1 Connection Time ................................................................................................................. 251
14 PAG .....................................................................................................................................252
14.1 Paging Performance ................................................................................................................. 252
15 Power .....................................................................................................................................254
15.1 Power ........................................................................................................................................ 254
15.2 RNTP of own cell ...................................................................................................................... 256
15.3 RRH_RSSI ................................................................................................................................ 262
16 RA .....................................................................................................................................263
16.1 Random Access Preambles..................................................................................................... 263
17 HARQ .....................................................................................................................................265
17.1 DL/UL Transmission ................................................................................................................. 265
18 Timing Alignment ...................................................................................................................277
18.1 Timing Alignment ...................................................................................................................... 277
19 AMC .....................................................................................................................................280
19.1 MIMO Performance .................................................................................................................. 280
19.2 MCS Performance .................................................................................................................... 282
19.3 DL MCS ..................................................................................................................................... 321
19.4 DL LAYER ................................................................................................................................. 326
19.5 DL CQI....................................................................................................................................... 327
19.6 DL PMI....................................................................................................................................... 332
19.7 DL RI ......................................................................................................................................... 334
19.8 DL ACK/NACK/DTX Ratio ........................................................................................................ 336
20 IOT .....................................................................................................................................338
20.1 Uplink IOT Level ....................................................................................................................... 338
Ver.
TABLE OF CONTENTS
© SAMSUNG Electronics Co., Ltd. page 10 of 427
2600-00FET7GAT 6.0
21 MLBO ..................................................................................................................................... 344
21.1 Load ........................................................................................................................................... 344
21.2 Load Balancing Handover ........................................................................................................ 346
22 Message ................................................................................................................................. 348
22.1 Protocol Message ..................................................................................................................... 348
22.2 RRC Message........................................................................................................................... 349
22.3 S1AP Message ......................................................................................................................... 354
22.4 X2AP Message ......................................................................................................................... 364
23 Traffic OAM ............................................................................................................................ 373
23.1 Throughput Distribution ............................................................................................................ 373
23.2 Delay Distribution ...................................................................................................................... 392
23.3 Drop Distribution ....................................................................................................................... 399
23.4 CQI Distribution ......................................................................................................................... 402
24 KPI ..................................................................................................................................... 404
24.1 ACCESSIBILITY ....................................................................................................................... 404
24.2 RETAINABILITY ....................................................................................................................... 407
24.3 RETAINABILITY (QCI) ............................................................................................................. 408
24.4 INTEGRITY ............................................................................................................................... 409
24.5 AVAILABILITY ........................................................................................................................... 411
24.6 MOBILITY ................................................................................................................................. 413
24.7 SUCCESS_RATE ..................................................................................................................... 419
24.8 Connection Drop Rate .............................................................................................................. 425
25 UE_Category .......................................................................................................................... 426
25.1 UE Category .............................................................................................................................. 426
LIST OF FIGURES
Figure 1. RRC/E-RAB/S1 SIG Statistics Processing .................................................................. 37
Figure 2. Collection Time for RRC Connection Establishment .................................................... 42
Figure 3. Collection Time for RRC Connection Reconfiguration ................................................. 44
Figure 4. Collection Time for RRC Connection Reestablishment ............................................... 48
Figure 5. Collection Time for RRC Connection Release ............................................................. 53
Figure 6. Collection Time for RRC Connection Number ............................................................. 58
Figure 7. Collection Time for RRC Connection Reestablishment Time ....................................... 61
Figure 8. Collection Time for E-RAB Setup ................................................................................ 68
Figure 9. Collection Time for E-RAB Setup Add ......................................................................... 72
Figure 10. Collection Time for E-RAB Setup Time ...................................................................... 74
Figure 11. Collection Time for eNB E-RAB Erase Request......................................................... 77
Ver.
TABLE OF CONTENTS
© SAMSUNG Electronics Co., Ltd. page 11 of 427
2600-00FET7GAT 6.0
Figure 12. Collection Time for E-RAB Erase ...............................................................................79
Figure 13. Collection Time for E-RAB Modify ..............................................................................83
Figure 14. Collection Time for eNB E-RAB Erase Request .........................................................85
Figure 15. Collection Time for E-RAB Release ...........................................................................87
Figure 16. Intra eNB Handover Statistics Processing .................................................................91
Figure 17. X2-based Handover Statistics Processing .................................................................92
Figure 18. S1-based Handover Procedure .................................................................................95
Figure 19. Collection Time for Intra eNB Handover ...................................................................102
Figure 20. Collection Time for X2 Handover Out .......................................................................107
Figure 21. Collection Time for X2 Handover In ......................................................................... 114
Figure 22. Collection Time for S1 Handover Out ....................................................................... 118
Figure 23. Collection Time for S1 Handover In .........................................................................124
Figure 24. Collection Time for Handover Time (INTRA) ............................................................127
Figure 25. Collection Time for Handover Time (INTER S1) ......................................................128
Figure 26. Collection Time for Handover Time (INTER X2) ......................................................129
Figure 27. PS Handover Procedure from E-UTRAN to UTRAN ................................................157
Figure 28. Collection Time for Inter-RAT UTRAN PS Handover Out .........................................163
Figure 29. Collection Time for Inter-RAT UTRAN PS Handover In............................................168
Figure 30. Collection Time for CSFB PS Handover Out ............................................................176
Figure 31. Collection Time for CSFB Redirection Out ...............................................................178
Figure 32. Collection Time for UE-associated Logical S1-Connection Establishment ...............250
Figure 33. Collection Time for Paging Performance ..................................................................253
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 12 of 427
2600-00FET7GAT 6.0
Statistics Items
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 13 of 427
2600-00FET7GAT 6.0
1 Resource Management This section provides statistics on the resource status of the system.
1.1 Resource
This section provides statistics on the CPU, memory and disk resources used by internal applications in the system.
The statistics data is described below:
CPU usage: Average, maximum and minimum CPU usage in %.
Memory usage: Average, maximum and minimum DRAM usage in %.
Disk usage: Average, maximum and minimum disk usage in %.
Index
Name Range Description
ShelfId 0~8 Shelf ID.
SlotId 0~5 The ID of the slot where the board is mounted.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
MemUsageAvg % Average memory
usage
Y GAUGE 10 s. float 0-100 MemUsageTot/
MemUsageCnt
sum (MemUsageTot)/
sum (MemUsageCnt)
MemUsageMin % Minimum memory
usage
Y GAUGE 10 s. float 0-100 - min (MemUsageMin)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 14 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
MemUsageMax % Maximum memory
usage
Y GAUGE 10 s. float 0-100 - max (MemUsageMax)
MemUsageTot % Cumulative
MemUsageAvg
- GAUGE 10 s float 0~3.4*10^38 - -
MemUsageCnt count MemUsage_AVG
collection count
- GAUGE 10 s int 0~2147483647 - -
CpuUsageAvg % Average CPU usage Y GAUGE 10 s. float 0-100 CpuUsageTot/
CpuUsageCnt
sum (CpuUsageTot)/
sum (CpuUsageCnt)
CpuUsageMin % Minimum CPU usage Y GAUGE 10 s. float 0-100 - min (CpuUsageMin)
CpuUsageMax % Maximum CPU
usage
Y GAUGE 10 s. float 0-100 - max (CpuUsageMax)
CpuUsageMaxDu
ration
s Maximum CPU
usage time
Y CC 10 s. int 0-60*Period - max
(CpuUsageMaxDuration)
CpuUsageTot % Cumulative
CpuUsageAvg
- GAUGE 10 s float 0~3.4*10^38 - -
CpuUsageCnt count CPUUsage_AVG
collection count
- GAUGE 10 s int 0~2147483647 - -
DiskUsageAvg % Average disk usage Y GAUGE 10 s. float 0-100 DiskUsageTot/
DiskUsageCnt
sum (DiskUsageTot)/
sum (DiskUsageCnt)
DiskUsageMin % Minimum disk usage Y GAUGE 10 s. float 0-100 - min (DiskUsageMin)
DiskUsageMax % Maximum disk usage Y GAUGE 10 s. float 0-100 - max (DiskUsageMax)
DiskUsageTot % Cumulative
DiskUsageAvg
- GAUGE 10 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 15 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
DiskUsageCnt count DISKUsage_AVG
collection count
- GAUGE 10 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 16 of 427
2600-00FET7GAT 6.0
2 Packet Statistics This section provides statistics on Tx/Rx packets that are processed by the system.
2.1 Ethernet Interface
This section provides details on the number of the Rx/Tx packets or bytes for each port connected to the backhaul. Collects the error
Ethernet frame count, Tx/Rx link usage, Tx/Rx error rate, etc.
Index
Name Range Description
PortNum 0~3 Port number
0: BH 0
1: BH 1
2: BH 2
3: BH 3
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RX_LinkUtilizati
on
% Average link utilization
of packets received
Y OW Period float 0~100 RX_GoodOctetSum
BadOctet_TOT*8*1
00*1024*1024+((R
X_UnicastPacket+R
X_BroadcastPacket
+RX_MulticastPack
et)*20)*8*100)/(10*
(sum
(RX_GoodOctetSum
BadOctet_TOT)*8*10
0*1024*1024+((sum
(RX_UnicastPacket)
+sum
(RX_BroadcastPacke
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 17 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RX_GoodOctetSum
BadOctet_CNT*IfSp
eed*1000000)
t)+sum
(RX_MulticastPacket)
)*20)*8*100)/(10*sum
(RX_GoodOctetSum
BadOctet_CNT)*avg
(IfSpeed)*1000000)
RX_LinkUtilizati
on_MAX
% Maximum link
utilization of packets
received
Y GAUGE 10 s float 0~100 - max
(RX_LinkUtilization_
MAX)
RX_ErrorRate % Ratio of error packets
received
Y OW Period float 0~100 (RX_FifoOverrun+R
X_Undersize+RX_F
ragment+RX_Overs
ize+RX_Jabber+RX
_ErrorFrame+RX_B
adCRC+RX_Collisi
on+RX_LateCollisio
n)*100/(RX_Unicast
Packet+RX_Broadc
astPacket+RX_Mult
icastPacket+RX_Fif
oOverrun+RX_Und
ersize+RX_Fragme
nt+RX_Oversize+R
X_Jabber+RX_Erro
rFrame+RX_BadC
RC+RX_Collision+
RX_LateCollision)
(sum
(RX_FifoOverrun)+
sum
(RX_Undersize)+sum
(RX_Fragment)+sum
(RX_Oversize)+sum
(RX_Jabber)+sum
(RX_ErrorFrame)+su
m
(RX_BadCRC)+sum
(RX_Collision)+sum
(RX_LateCollision))*1
00/(sum
(RX_UnicastPacket)+
sum
(RX_BroadcastPacke
t)+sum
(RX_MulticastPacket)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 18 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
+sum
(RX_FifoOverrun)
+sum
(RX_Undersize)+sum
(RX_Fragment)+sum
(RX_Oversize)+sum
(RX_Jabber)+sum
(RX_ErrorFrame)
+sum
(RX_BadCRC)+sum
(RX_Collision)+sum
(RX_LateCollision))
RX_GoodOctet Mbytes Total frame length of
normal packets
received
Y CC 10 s. int 0~2147483647 - -
RX_UnicastPack
et
count Number of unicast
packets received
Y CC 10 s. int 0~2147483647 - -
RX_BroadcastP
acket
count Number of broadcast
packets received
Y CC 10 s. int 0~2147483647 - -
RX_MulticastPac
ket
count Number of multicast
packets received
Y CC 10 s. int 0~2147483647 - -
RX_FifoOverrun count Number of packets
dropped due to
insufficient buffer
resources among
packets received
Y CC 10 s. int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 19 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RX_Undersize count Number of undersized
packets among error
packets received
Y CC 10 s. int 0~2147483647 - -
RX_Fragment count Number of
fragmented packets
among error packets
received
Y CC 10 s. int 0~2147483647 - -
RX_Oversize count Number of oversized
packets among error
packets received
Y CC 10 s. int 0~2147483647 - -
RX_Jabber count Number of jabber
packets among error
packets received
Y CC 10 s. int 0~2147483647 - -
RX_ErrorFrame count Number of errors
received
Y CC 10 s. int 0~2147483647 - -
RX_BadCRC count Number of CRC error
packets received
Y CC 10 s. int 0~2147483647 - -
RX_Collision count Number of packets
received, where
collision occurred
Y CC 10 s. int 0~2147483647 - -
RX_LateCollision count Number of packets
received, where late
collision occurred
Y CC 10 s. int 0~2147483647 - -
TX_LinkUtilization % Average link utilization
of packets transmitted
Y OW Period float 0~100 (TX_GoodOctetSu
mBadOctet_TOT*8*
(sum
(TX_GoodOctetSum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 20 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
100*1024*1024+(T
X_UnicastPacket+T
X_BroadcastPacket
+TX_MulticastPack
et)*20)*8*100)/(10*
TX_GoodOctetSum
BadOctet_CNT*IfSp
eed*1000000)
BadOctet_TOT)*8*10
0*1024*1024+((sum
(TX_UnicastPacket)+
sum
(TX_BroadcastPacke
t)+sum
(TX_MulticastPacket)
)*20)*8*100)
/(10*sum
(TX_GoodOctetSum
BadOctet_CNT)*avg
(IfSpeed)*1000000)
TX_LinkUtilizatio
n_MAX
% Maximum link
utilization of packets
transmitted
Y GAUGE 10 s. float 0~100 - max
(TX_LinkUtilization_
MAX)
TX_ErrorRate % Ratio of error packets
transmitted
Y OW Period float 0~100 (TX_Underrun_Bad
CRC+TX_Deferred
+TX_E_Collisions)*
100/(TX_UnicastPa
cket+TX_Broadcast
Packet+TX_Multica
stPacket+TX_Unde
rrun_BadCRC+TX_
Deferred+TX_E_Co
llisions)
(sum
(TX_Underrun_BadC
RC)+sum
(TX_Deferred)+sum
(TX_E_Collisions))*1
00/(sum
(TX_UnicastPacket)+
sum
(TX_BroadcastPacke
t)+sum
(TX_MulticastPacket)
+sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 21 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
(TX_Underrun_BadC
RC)+sum
(TX_Deferred)+sum
(TX_E_Collisions))
TX_GoodOctet Mbytes Total frame length of
normal packets
transmitted
Y CC 10 s. int 0~2147483647 - -
TX_UnicastPack
et
count Number of unicast
packets transmitted
Y CC 10 s. int 0~2147483647 - -
TX_BroadcastP
acket
count Number of broadcast
packets transmitted
Y CC 10 s. int 0~2147483647 - -
TX_MulticastPac
ket
count Number of multicast
packets transmitted
Y CC 10 s. int 0~2147483647 - -
TX_Underrun_B
adCRC
count Number of packets
transmitted, where
underrun or CRC
error occurred
Y CC 10 s. int 0~2147483647 - -
TX_Deferred count Number of delayed
transmissions due to
‘media busy’ state
when ports are open
in half-duplex mode
Y CC 10 s. int 0~2147483647 - -
TX_E_Collisions count Number of packets
whose transmission is
cancelled due to
excessive collision
Y CC 10 s. int 0~2147483647 -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 22 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
when ports are open
in half-duplex mode
RX_GoodOctetS
umBadOctet
Mbytes RX
GoodOctet+BadOctet
- GAUGE 10 s. int 0~2147483647 RX_GoodOctetSum
BadOctet_TOT/RX_
GoodOctetSumBad
Octet_CNT
sum
(RX_GoodOctetSum
BadOctet_TOT)/sum
(RX_GoodOctetSum
BadOctet_CNT)
RX_GoodOctetS
umBadOctet_M
AX
Mbytes RX_GoodOctet+BadO
ctet_MAX
- GAUGE 10 s. int 0~2147483647 - max
(RX_GoodOctetSum
BadOctet_MAX)
RX_GoodOctetSu
mBadOctet_TOT
Mbytes RX_GoodOctet+BadO
ctet_TOT
- GAUGE 10 s. int 0~2147483647 - -
RX_GoodOctetS
umBadOctet_C
NT
count RX_GoodOctet+BadO
ctet_CNT
- GAUGE 10 s. int 0~2147483647 - -
TX_GoodOctetS
umBadOctet
Mbytes TX
GoodOctet+BadOctet
- GAUGE 10 s. int 0~2147483647 TX_GoodOctetSum
BadOctet_TOT/TX_
GoodOctetSumBad
Octet_CNT
sum
(TX_GoodOctetSum
BadOctet_TOT)/sum
(TX_GoodOctetSum
BadOctet_CNT)
TX_GoodOctetS
umBadOctet_M
AX
Mbytes TX_GoodOctet+BadO
ctet_MAX
- GAUGE 10 s. int 0~2147483647 - max
(TX_GoodOctetSum
BadOctet_MAX)
TX_GoodOctetSu
mBadOctet_TOT
Mbytes TX_GoodOctet+BadO
ctet_TOT
- GAUGE 10 s. int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 23 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TX_GoodOctetS
umBadOctet_C
NT
count TX_GoodOctet+BadO
ctet_CNT
- GAUGE 10 s. int 0~2147483647 - -
IfSpeed Mbps ifSpeed - OW 10 s. int 0~2147483647 - avg (IfSpeed)
RX_LinkUtilizati
on_MIN
% Minimum link
utilization of packets
received from the
outside
Y GAUGE 10 s float 0~100 - min
(RX_LinkUtilization_
MIN)
TX_LinkUtilizatio
n_MIN
% Minimum link
utilization of packets
transmitted to the
outside
Y GAUGE 10 s float 0~100 - min
(TX_LinkUtilization_
MIN)
RX_GoodOctetS
umBadOctet_MIN
Mbytes RX_GoodOctet+BadO
ctet_MIN
- GAUGE 10 s int 0~2147483647 - min
(RX_GoodOctetSum
BadOctet_MIN)
TX_GoodOctetSu
mBadOctet_MIN
Mbytes TX_GoodOctet+BadO
ctet_MIN
- GAUGE 10 s int 0~2147483647 - min
(TX_GoodOctetSum
BadOctet_MIN)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 24 of 427
2600-00FET7GAT 6.0
2.2 Histogram
This section provides the number of packets per Ethernet packet size received from a backhaul port.
Index
Name Range Description
PortNum 0~3 Port number
0: BH 0
1: BH 1
2: BH 2
3: BH 3
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RX_Histogram_64 count Number of 64-byte
Ethernet frames received
from the Ethernet port
Y CC 10 s. int 0-2147483647 - -
RX_Histogram_127 count Number of 65 to 127-byte
Ethernet frames received
from the Ethernet port
Y CC 10 s. int 0-2147483647 - -
RX_Histogram_255 count Number of 128 to 255-byte
Ethernet frames received
from the Ethernet port
Y CC 10 s. int 0-2147483647 - -
RX_Histogram_511 count Number of 256 to 511-byte
Ethernet frames received
from the Ethernet port
Y CC 10 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 25 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RX_Histogram_1023 count Number of 512 to 1023-
byte Ethernet frames
received from the Ethernet
port
Y CC 10 s. int 0-2147483647 - -
RX_Histogram_max count Number of 1024-byte
Ethernet frames received
from the Ethernet port
Y CC 10 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 26 of 427
2600-00FET7GAT 6.0
2.3 Air Mac UL/DL bytes (Kbytes)
This section provides statistics for the cell throughput. Collects the average size of the transport block (TB) successfully sent/received,
among the downlink/uplink TBs that the eNB’s MAC allocated to the UE.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirMacByteUl Kbytes The sum of the size of the MAC
PDU successfully received via
PUSCH during the statistics period.
Y CC 5.12 s. int 0-2147483647 -
AirMacByteUlCnt count Collected AirMacByteUl count - CC_LL 5.12 s int 0~2147483647 - -
AirMacTtiUl TTI The sum of sections that have
the MAC PDU successfully
received via PUSCH during the
statistics period.
Y CC 5.12 s. int 0~2147483647 - -
AirMacUlThru Kbps Average size per second of the
MAC PDU successfully received
via PUSCH.
Y OW Period float 0-3.4*10^38 ((AirMacByt
eUl*8)/(512
0*AirMacBy
teUlCnt))*1
024
((sum
(AirMacByteUl)*8)/
(5120*sum
(AirMacByteUlCnt))
)*1024
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 27 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirMacUlEfctivThru Kbps Average size of the MAC PDU of
the section successfully received
via PUSCH during the statistics
period.
Y OW Period float 0-3.4*10^38 ((AirMacByt
eUl*8)/AirM
acTtiUl)*10
24
((sum
(AirMacByteUl)*8)/
sum (AirMacTtiUl))
*1024
AirMacByteDl Kbytes The sum of the size of the DCCT/
DTCH MAC PDU that received
HARQ ACK among the MAC PDU
transmitted via PDSCH during the
statistics period.
Y CC 5.12 s. int 0-2147483647 - -
AirMacByteDlCnt count Collected AirMacByteDl count - CC_LL 5.12 s int 0~2147483647 - -
AirMacTtiDl TTI The sum of sections that have
the MAC PDU successfully
transmitted via PDSCH during
the statistics period.
Y CC 5.12 s. int 0-2147483647 - -
AirMacDlThru Kbps Average size per second of the
DCCT/DTCH MAC PDU that
received HARQ ACK among the
MAC PDU transmitted via
PDSCH during the statistics
period.
Y OW Period float 0-3.4*10^38 ((AirMacByt
eDl*8)/(512
0*AirMacBy
teDlCnt))*1
024
((sum
(AirMacByteDl)*8)/
(5120*sum
(AirMacByteDlCnt))
)*1024
AirMacDlEfctivThru Kbps Average size of the MAC PDU of
the section successfully
transmitted via PDSCH during
the statistics period
Y OW Period float 0-3.4*10^38 ((AirMacByt
eDl*8)/AirM
acTtiDl)*10
24
((sum
(AirMacByteDl)*8)/
sum (AirMacTtiDl))
*1024
AirMacByteUlCurr
ent
Kbytes The most recently collected
AirMacByteUl value
- CC_LL 5.12 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 28 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirMacByteDlCurr
ent
Kbytes The most recently collected
AirMacByteDl value
- CC_LL 5.12 s int 0~2147483647 - -
AirMacUlThruMin Kbps Minimum of the average size per
second of the MAC PDU
successfully received via PUSCH
Y OW 5.12 s. float 0-3.4*10^38 - min
(AirMacUlThruMin)
AirMacUlThruMax Kbps Maximum of the average size per
second of the MAC PDU
successfully received via PUSCH
Y OW 5.12 s. float 0-3.4*10^38 - max
(AirMacUlThruMax)
AirMacDlThruMin Kbps Minimum of the average size per
second of the DCCT/DTCH MAC
PDU that received HARQ ACK
among the MAC PDU transmitted
via PDSCH during the statistics
period
Y OW 5.12 s. float 0-3.4*10^38 - min
(AirMacDlThruMin)
AirMacDlThruMax Kbps Maximum of the average size per
second of the DCCT/DTCH MAC
PDU that received HARQ ACK
among the MAC PDU transmitted
via PDSCH during the statistics
period
Y OW 5.12 s. float 0-3.4*10^38 - max
(AirMacDlThruMax)
Collection Time
TTI (Transmission Time Interval: 1 ms)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 29 of 427
2600-00FET7GAT 6.0
2.4 Air RLC UL/DL bytes
This section provides statistics for the downlink’s transmitted byte and retransmitted byte count/throughput/IP throughput and the uplink’
s transmitted byte count/throughput for the wireless section of the eNB. Since they are collected and summed for each cell and each
QCI, they are collected after cell setup has finished.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirRlcByteUl Kbytes Air RLC uplink bytes
Number of bytes
transmitted at the RLC as
air uplink. Collects the
number of data bytes
received by the UE for
each cell and QCI.
Y CC 10 s. int 0-2147483647 - -
AirRlcByteDl Kbytes Air RLC downlink bytes
Number of bytes
transmitted at the RLC as
air downlink. Collects the
Y CC 10 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 30 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
number of data bytes
transmitted to the UE for
each cell and QCI.
AirRlcByteDlRe Kbytes Air RLC downlink ReTx
bytes
Number of bytes
retransmitted at the RLC
as air downlink. Collects
the number of data bytes
transmitted to the UE for
each cell and QCI.
Y CC 10 s. int 0-2147483647 - -
AirUlThru Kbps Air uplink throughput
Collects the data
received from the UE as
the air uplink throughput
for each cell and QCI.
Y OW 10 s. float 0-3.4*10^38 (AirRlcByte
Ul*1024*8)/
(10*RlcAirB
yteUlCnt*10
00)
(sum
(AirRlcByteUl)*102
4*8)/(10*sum
(RlcAirByteUlCnt)*
1000)
AirUlThruTot Kbps The sum of collected
AirUlThru
OW 10 s float 0~3.4*10^38 - -
AirUlThruCnt count Collected AirUlThru count OW 10 s int 0~2147483647 - -
AirDlThru Kbps Air downlink throughput
Collects the data
transmitted to the UE as
the air downlink
throughput for each cell
and QCI.
Y OW 10 s. float 0-3.4*10^38 (AirRlcByte
Dl*1024*8)/
(10*RlcAirB
yteDlCnt*10
00)
(sum
(AirRlcByteDl)*102
4*8)/(10*sum
(RlcAirByteDlCnt)*
1000)
AirDlThruTot Kbps The sum of collected OW 10 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 31 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirDlThru
AirDlThruCnt count Collected AirDlThru count OW 10 s int 0~2147483647 - -
IpThru Kbps IP throughput
Collects the IP
throughput for each cell
and QCI using the
method specified in
3GPP TS 32.450.
Y SI 10 s. float 0-3.4*10^38 IpThruTot/Ip
ThruCn
sum (IpThruTot)/
sum (IpThruCnt)
IpThruTot Kbps The sum of collected
IpThru
SI 10 s float 0~3.4*10^38 - -
IpThruCnt count Collected IpThru count SI 10 s int 0~2147483647 - -
RlcAirByteUlCurrent Kbytes The most recently
collected RlcAirByteUl
CC 10 s int 0~2147483647 - -
RlcAirByteDlCurrent Kbytes The most recently
collected RlcAirByteDl
CC 10 s int 0~2147483647 - -
RlcAirByteUlCnt count RlcAirByteUl collection
count
CC 10 s int 0~2147483647 - -
RlcAirByteDlCnt count RlcAirByteDl collection
count
CC 10 s int 0~2147483647 - -
AirUlThruMin Kbps Air uplink throughput Min Y OW 10 s. float 0-3.4*10^38 - min
(AirUlThruMin)
AirUlThruMax Kbps Maximum air uplink
throughput
Y OW 10 s. float 0-3.4*10^38 - max
(AirUlThruMax)
AirDlThruMin Kbps Minimum air downlink
throughput
Y OW 10 s. float 0-3.4*10^38 - min
(AirDlThruMin)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 32 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AirDlThruMax Kbps Maximum air downlink
throughput
Y OW 10 s. float 0-3.4*10^38 - max
(AirDlThruMax)
IpThruMin Kbps Minimum IP throughput Y OW 10 s. float 0-3.4*10^38 - min (IpThruMin)
IpThruMax Kbps Maximum IP throughput Y OW 10 s. float 0-3.4*10^38 - max (IpThruMax)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 33 of 427
2600-00FET7GAT 6.0
2.5 S-GW UL/DL packets
This section provides statistics for bytes, packet counts and throughput of user data transmitted and received between the eNB and S-G
W, which are collected per QCI according to the 3GPP standard (TS32.425 Performance Measurements). Each item is collected by the
PDCP layer within the eNB.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ByteUleNBQCI Kbytes Total bytes of user data
transmitted from the eNB to the
S-GW.
Y CC 2 s. int 0-2147483647 - -
ThruUleNBQCI Kbps (Total bits of user data
transmitted to the S-GW)/(Total
time when user data were
transmitted)
Y GAUGE 2 s. float 0-3.4*10^38 (ByteUleNBQ
CI*1024*8)/(2
*ByteUleNBQ
CICnt)/1000
(sum
(ByteUleNBQCI)*1
024*8)/(2*sum
(ByteUleNBQCICnt
))/1000
ThruUleNBQCIM
ax
Kbps Maximum value over a five-
minute period of (Total bits of
user data transmitted to the S-
Y GAUGE 2 s. float 0-3.4*10^38 - max
(ThruUleNBQCIMa
x)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 34 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
GW)/(Total time when user
data were transmitted).
ThruUleNBQCITot Kbps The sum of collected
ByteUleNBQCI
GAUGE 2 s float 0~3.4*10^38 - -
ThruUleNBQCIC
nt
count Collected ByteUleNBQCI count GAUGE 2 s int 0~214748364
7
- -
PacketCntUl count Total number of packets
transmitted from the eNB to the
S-GW
Y CC 2 s. int 0-2147483647 - -
ByteDleNBQCI Kbytes Total bytes of user data the
eNB received from the S-GW.
Y CC 2 s. int 0-2147483647 - -
ThruDleNBQCI Kbps (Total bits of user data received
from the S-GW)/(Total time
when user data were received)
Y GAUGE 2 s. float 0-3.4*10^38 (ByteDleNBQ
CI*1024*8)/(2
*ByteDleNBQ
CICnt)/1000
(sum
(ByteDleNBQCI)*1
024*8)/(2*sum
(ByteDleNBQCICnt
))/1000
ThruDleNBQCIM
ax
Kbps Maximum value over a five-
minute period of (Total bits of
user data transmitted to the S-
GW)/(Total time when user
data were transmitted)
Y GAUGE 2 s. float 0-3.4*10^38 - max
(ThruDleNBQCIMa
x)
ThruDleNBQCITot Kbps The sum of collected
ThruDleNBQCI
GAUGE 2 s float 0~3.4*10^38 - -
ThruDleNBQCIC
nt
count Collected ThruDleNBQCI count GAUGE 2 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 35 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PacketCntDl count Total number of packets the
eNB received from the S-GW
Y CC 2 s. int 0-2147483647 - -
ByteUleNBQCICnt count Collection count of the total
bytes of user data transmitted
from the eNB to the S-GW.
Y CC 2 s. int 0-2147483647 - -
ByteDleNBQCICnt count Collection count of the total
bytes of user data the eNB
received from the S-GW.
Y CC 2 s. int 0-2147483647 - -
ThruUleNBQCIMin Kbps Minimum value over a five-
minute period of (Total bits of
user data transmitted to the S-
GW)/(Total time when user
data were transmitted)
Y GAUGE 2 s. float 0-3.4*10^38 - min
(ThruUleNBQCIMin)
ThruDleNBQCIMin Kbps Minimum value over a five-
minute period of (Total bits of
user data transmitted to the S-
GW)/(Total time when user
data were transmitted)
Y GAUGE 2 s. float 0-3.4*10^38 - min
(ThruDleNBQCIMin)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 36 of 427
2600-00FET7GAT 6.0
2.6 VPN Interface
This section provides statistics for IPSec Tunnel.
Index
Name Range Description
VPNNum 0~5 VPN Number
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
VPN_RxOctet Mbyte Rx octet count for IPSec tunnel. Y CC_LL 10 s int 0~2147483647 - -
VPN_RxPacket count Rx packet count for IPSec tunnel. Y CC 10 s int 0~2147483647 - -
VPN_RxDropPacket count Rx drop packet count for IPSec
tunnel.
Y CC 10 s int 0~2147483647 - -
VPN_TxOctet Mbyte Tx octet count for IPSec tunnel. Y CC_LL 10 s int 0~2147483647 - -
VPN_TxPacket count Tx packet count for IPSec tunnel. Y CC 10 s int 0~2147483647 - -
VPN_TxDropPacket count Tx drop packet count for IPSec
tunnel.
Y CC 10 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 37 of 427
2600-00FET7GAT 6.0
3 RRC The following shows the statistical definition and message flow for each stage of th
e Idle to Active (Service Request) procedure by the UE, which allows to identify t
he overall handling of the RRC/E-RAB/S1 SIG statistics.
Figure 1. RRC/E-RAB/S1 SIG Statistics Processing
[1] RRC establishment
[3] E-RAB
establishment
[2] S1SIG setup
UE eNB MME S-GW
EPC
1) Random Access procedure
2) RRCConnectionRequest
3) RRCConnectionSetup
4) RRCConnectionSetupComplete
(SERVICE REQUEST) 5) INITIAL UE MESSAGE
(SERVICE REQUEST)
6) Authentication/NAS security setup
8) SecurityModeCommand
9) SecurityModeComplete
10) RRCConnectionReconfiguration
11) RRCConnectionReconfiguration Complete
(SERVICE ACCEPT)
12) INITIAL CONTEXT SETUP RESPONSE
(SERVICE ACCEPT)
7) INITIAL CONTEXT SETUP REQUEST
13) Modify Bearer Request
14) Modify Bearer Response
Downlink data Downlink data
Uplink data Uplink data
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 38 of 427
2600-00FET7GAT 6.0
Step Description
1) The UE performs the Random Access procedure with the eNB.
2)-4) The UE transmits the NAS SERVICE REQUEST message to the MME. The SERVICE
REQUEST message is encapsulated in an RRC message transmitted to the eNB.
5) The eNB transmits the SERVICE REQUEST message to the MME. The SERVICE
REQUEST is encapsulated in an S1-AP INITIAL UE message.
6) If there is no UE context for the UE in the network, the integrity is not protected for the
ATTACH REQUEST message, or the integrity check fails, an authentication and an
NAS security setup are always performed. The UE performs the EPS AKA procedure
(TS 33.401, 6.1.1) with the MME. The MME sets up an NAS security association with
the UE using the NAS SMC procedure (TS 33.401, 7.2.4.4).
7) The MME transmits the S1-AP Initial Context Setup Request message to the eNB.
This step activates both the radio bearer and S1 bearer for all active EPS bearers.
8)-11) The eNB sets up the RRC radio bearers. The user plane security is set up at this step.
The uplink data from the UE can be sent to the S-GW by the S-GW.
The eNB transmits the uplink data to the S-GW, and then the S-GW transmits it to the
P-GW.
12) The eNB transmits the S1-AP Initial Context Setup Request message to the MME.
13)-14) The MME transmits the Modify Bearer Request message for each PDN connection to
the S-GW.
Now, the S-GW can transmit the downlink data to the UE. The S-GW transmits the
Modify Bearer Response message to the MME.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 39 of 427
2600-00FET7GAT 6.0
3.1 RRC Connection Establishments
This section provides access statistics between RRC connection request and RRC connection setup complete are collected for each cell.
The access call is identified by the establishment cause within the RRC connection request message initially informed by the UE.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnEstabAtt count The attempt count for RRC
ESTAB
Y CC event int 0-2147483647 - -
ConnEstabSucc count RRC ESTAB success count. Y CC event int 0-2147483647 - -
ConnEstabFail_CP
_CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 40 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
during RRC establishment.
ConnEstabFail_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
during RRC establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_UP
_MAC_FAIL
count A call is released due to the
failure in the MAC block during
RRC establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_UP
_PDCP_FAIL
count A call is released due to the
failure in the PDCP block during
RRC establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_UP
_RLC_FAIL
count A call is released due to the
failure in the RLC block during
RRC establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_RR
C_SIG_TO
count A call is released due to RRC
uplink message timeout (not
received) during RRC
establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_S1A
P_LINK_FAIL
count A call is released due to S1 SCTP
link failure during RRC
establishment.
Y CC event int 0-2147483647 - -
ConnEstabFail_S1A
P_SIG_FAIL
count A call is released due to receiving
S1AP signaling during RRC
establishment.
Y CC event int 0-2147483647 - -
ConnEstabReject_C count A call cannot be accepted Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 41 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
P_CC_FAIL because the cell is barred after
receiving the RRC Connection
Request message, or there is no
MME available for service during
RRC establishment.
ConnEstabReject_C
P_CAPA_CAC_FAI
L
count A call cannot be accepted due to
Call Admission Control after
receiving the RRC Connection
Request message during RRC
establishment.
Y CC event int 0-2147483647 - -
ConnEstabReject_S
1AP_MME_OVLD
count A call cannot be accepted due to
MME overload during RRC
establishment.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 42 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 2. Collection Time for RRC Connection Establishment
For statistics on RRC connection establishment, Attempt, Success, Fail and Reject statistics are counted. The Attempt statistic is counte
d when the RRC Connection Request message is received. Success statistic is counted when the messages up to RRC Connection Setu
p Complete are successfully received.
When a timeout or internal failure occurs during the procedure from 1 to 2, as indicated in the figure above, it is counted as Fail, ret
urning the cause value. Reject statistic is counted when the eNB determines that the call cannot be accepted after receiving the RRC
Connection Request message, and the applicable cause value is recorded.
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Random Access Preamble
Random Access Response
Rrc Connection Request
Rrc Connection Setup
Rrc Connection Setup Complete
Initial UE Message
1
2
Attempt
Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 43 of 427
2600-00FET7GAT 6.0
3.2 RRC Connection Reconfiguration
This section provides statistics for RRC Connection Reconfiguration’s count. There is no Fail statistic as the RRC Connection Reconfig
uration message is transmitted down from the Serving eNB and the RRC Connection Reconfiguration Complete message is transmitted
to the Target eNB. In this case, the attempt and success counts in the reconfiguration statistics for the system can be different.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnReconfigAtt count RRC Connection
Reconfiguration attempt count.
Y CC event int 0-2147483647 - -
ConnReconfigSu
cc
count RRC Connection
Reconfiguration success count.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 44 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 3. Collection Time for RRC Connection Reconfiguration
The transmission of the RRC Connection Reconfiguration to the UE is counted as Attempt, while the receipt of RRC Connection Reco
nfiguration Complete from the UE is counted as Success. Upon handover, the source eNB transmits RRC Connection Reconfiguration
(handover command) to the UE; the UE transmits RRC Connection Reconfiguration Complete (handover command complete) to the tar
get eNB. Therefore, a fail count is not returned because it is not possible to determine transmission failure.
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Rrc Connection Reconfiguration
Rrc Connection Reconfiguration Complete
1
2
Attempt
Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 45 of 427
2600-00FET7GAT 6.0
3.3 RRC Connection Reestablishment
As shown below, when a RRC Reestablishment cause occurs with the UE in RRC connected state, statistics on the RRC connection R
eestablishment are collected for each cell.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
ReEstabCause 0~3 RRC Connection Reestablishment Cause
- 0 (reconfigurationFailure): Reestablishment occurs due to reconfiguration failure
- 1 (handoverFailure): Reestablishment occurs due to handover failure
- 2 (otherFailure): Reestablishment occurs due to other failures
- 3: reserved
Type
Name Unit Description Visible Counter
Type
Collection
Time
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnReEstabAtt count The attempt count for
RRC_REESTAB
Y CC event int 0-2147483647 - -
ConnReEstabSucc count The success count for
RRC_REESTAB
Y CC event int 0-2147483647 - -
ConnReEstabFail_CP
_CC_FAIL
count A call is released due to
reset notification (eNB
failure or block restart) from
ECMB or by ECCB during
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 46 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Collection
Time
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RRC Reestablishment.
ConnReEstabFail_UP
_MAC_FAIL
count A call is released due to the
failure in the MAC block
during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabFail_UP
_PDCP_FAIL
count A call is released due to the
failure in the PDCP block
during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabFail_UP
_RLC_FAIL
count A call is released due to the
failure in the RLC block
during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabFail_RR
C_SIG_TO
count A call is released due to
RRC uplink message
timeout (not received)
during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabFail_S1
AP_LINK_FAIL
count A call is released due to
receiving S1AP signaling
during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabFail_S1
AP_SIG_FAIL
count A call is released due to
S1AP signaling timeout (not
received) during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 47 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Collection
Time
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnReEstabReject_
CP_CC_FAIL
count A call cannot be accepted
because the cell is barred
after receiving the RRC
Connection Request
message, or there is no
MME available for service
during RRC Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabReject_
CP_CAPA_CAC_FAIL
count A call cannot be accepted
due to Call Admission
Control after receiving the
RRC Connection Request
message during RRC
Reestablishment.
Y CC event int 0-2147483647 - -
ConnReEstabReject_
CP_QOS_CAC_FAIL
count A call cannot be accepted
due to insufficient QoS-
based eNB resources during
RRC Reestablishment.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 48 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 4. Collection Time for RRC Connection Reestablishment
When RRC Connection Reestablishment Request is received, it is counted as an attempt; if the call context exists in the eNB and the
security key value uploaded by the UE matches, RRC Connection Reestablishment is transmitted to the UE; and when RRC Connectio
n Reestablishment Complete is received, it is counted as Success. If a call text does not exist in the eNB or the security key value u
ploaded by the UE does not match, RRC Connection Reestablishment Reject is transmitted to the UE, and it is counted as Reject. The
n, if RRC Connection Reestablishment Complete is not received, the call is released.
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Rrc Connection Reestablishment
Rrc Connection Reestablishment Request
Rrc Connection Reestablishment Complete
1
2
Attempt
Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 49 of 427
2600-00FET7GAT 6.0
3.4 RRC Connection Release
This section provides statistics data for RRC Connection Release.
MME-initiated RRC connection release: The MME transmits the UE context release command to eNB to release the UE-associated logi
cal connection. Then, the eNB transmits the RRC connection release to the UE, releases the eNB resource, and transmits the UE conte
xt release complete to the MME to complete the call release procedure. An MME-initiated call release occurs in the following cases.
Case Number Description
1 A procedure between UE and MME is completed (e.g. Detach).
2 A call in the source eNB is released due to successful handover.
3 A call in the target eNB is released due to cancelled handover.
4 The old logical connection is to be released when 2 logical connections are established for a specific UE (e.g. when UE duplication occurs in
the MME).
5 The UE is not a CSG member of the CSL cell.
eNB-initiated RRC connection release: If the eNB MAC scheduler determines that the UE has no traffic for the specific period of time,
it transmits the UE context release request to the MME. Then the call release procedure is completed by an MME-initiated RRC con
nection release procedure. A call may be released by transmitting the UE context release request to the MME upon eNB failure or call
setup failure.
An eNB-initiated call release occurs in the following cases.
Case Number Description
1 A call is released by user inactivity.
2 A call is released by eNB Radio Link Fail (RLF).
3 A call is released by MAX retransmission at the RCL end.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 50 of 427
2600-00FET7GAT 6.0
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnRelease_CP_
CC_NORMAL
count A call is released in eNB upon
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_CP_
CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_CP_
CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_UP_
GTP_FAIL
count A call is released due to the
failure in the GTP block during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_UP_
MAC_FAIL
count A call is released due to the
failure in the MAC block during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_UP_
MAC_UE_INACT
count A call is released due to UE
inactivity in the eNB during RRC
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 51 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
release.
ConnRelease_UP_P
DCP_FAIL
count A call is released due to the
failure in the PDCP block during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_UP_
RLC_FAIL
count A call is released due to the
failure in the RLC block during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_RRC
_HC_TO
count A call is released due to HO
command timeout (not received)
during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_RRC
_SIG_FAIL
count A call is released due to
receiving RRC signaling during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_RRC
_SIG_TO
count A call is released due to RRC
uplink message timeout (not
received) during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_CP_B
H_CAC_FAIL
count A call is released due to
insufficient backhaul-based eNB
resources during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_CP_
CAPA_CAC_FAIL
count A call is released due to
insufficient capacity-based eNB
resources during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_CP_
QOS_CAC_FAIL
count A call is released due to
insufficient QoS-based eNB
resources during RRC release.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 52 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnRelease_S1AP
_CU_FAIL
count A call is released due to the
S1AP specification cause during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_S1AP
_LINK_FAIL
count A call is released due to S1 SCTP
link failure during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_S1AP
_RO_TO
count A call is released due to S1AP
relocoverall timeout (not
received) during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_S1AP
_SIG_FAIL
count A call is released due to
receiving S1AP signaling during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_S1AP
_SIG_TO
count A call is released due to S1AP
signaling timeout (not received)
during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_X2AP
_CU_FAIL
count A call is released due to the
X2AP specification cause during
RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_X2AP
_LINK_FAIL
count A call is released due to X2 SCTP
link failure during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_X2AP
_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not
received) during RRC release.
Y CC event int 0-2147483647 - -
ConnRelease_X2AP
_SIG_FAIL
count A call is released due to X2AP
signaling received during RRC
release.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 53 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 5. Collection Time for RRC Connection Release
Call statistics are released when RRC connection is released. Since RRC connection release cause is returned, it is possible to determin
e call release cause.
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Rrc Connection Release 1 Count
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 54 of 427
2600-00FET7GAT 6.0
3.5 RRC Connection number
This section provides statistics data for the average RRC connection count per unit time and the maximum RRC connection count for
each cell.
The RRC connection count is collected every 2 seconds, and the statistics block calculates the average, maximum and total values per
minute using the collected data
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
ConnNo count Average RRC connection
per unit time
Y GAUGE 2 s. float 0-3.4*10^38 ConnTot/Con
nCnt
sum (ConnTot)/sum
(ConnCnt)
ConnMax count Maximum RRC connection
per unit time
Y GAUGE 2 s. float 0-3.4*10^38 - max (ConnMax)
ConnTot count Sum of ConnNo collected Y GAUGE 2 s. float 0-3.4*10^38 - -
ConnCnt count Collected ConnNo count - GAUGE 2 s int 0~2147483647 - -
ReleaseCallHoldin
gTime
s Average Release Call
Holding Time during which
the RRC connection was
maintained which is
calculated based on call
release.
Y SI event float 0-60*Period ReleaseCall
HoldingTimeT
ot/ReleaseCa
llCnt
sum (ReleaseCall
HoldingTimeTot)/sum
(ReleaseCallCnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 55 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
ReleaseCallHoldin
gTimeTot
s Total RRC Connection
Release Call Holding Time
Y SI event float 0-60*Period - -
ReleaseCallCnt count Call Release Count Y SI event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 56 of 427
2600-00FET7GAT 6.0
3.6 RRC Connection Setup Time
This section provides statistics data for the average and maximum RRC Connection Setup times.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
Type
Name Unit Description Visible Counter
Type
Collection
Time
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
ConnEstabTime ms Average RRC
connection setup time
Y GAUGE event float 0-60*
Period*10
00
ConnEstabTimeTot/C
onnEstabTimeCnt
sum
(ConnEstabTimeTot)/
sum
(ConnEstabTimeCnt)
ConnEstabTimeMax ms Maximum RRC
connection setup time
Y GAUGE event float 0-60*
Period*10
00
- max
(ConnEstabTimeMax)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 57 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Collection
Time
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
ConnEstabTimeTot ms Sum of
ConnEstabTime
collected
Y GAUGE event float 0-
3.4*10^38
- -
ConnEstabTimeCnt count Collected
ConnEstabTime count
- GAUGE event int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 58 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 6. Collection Time for RRC Connection Number
The RRC Connection setup time is a time taken from receiving the RRC Connection Request message up to receiving the RRC Conne
ction Setup Complete message.
The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Rrc Connection Request
Rrc Connection Setup
Rrc Connection Setup Complete
Initial UE Message
RRC Connection Setup time
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 59 of 427
2600-00FET7GAT 6.0
3.7 RRC Connection Reestablishment Time
This section provides statistics data for the average and maximum RRC Connection Reestablishment Setup times.
The cause is identified by the RRC connection Reestablishment cause informed by the UE.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
ReEstabCause 0~3 RRC Connection Reestablishment Cause
0: reconfigurationFailure: Reestablishment occurs due to reconfiguration failure
1: handoverFailure: Reestablishment occurs due to handover failure
2: otherFailure: Reestablishment occurs due to other failures
3: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
ConnReEstab
Time
ms Average RRC
connection
reestablishment setup
time
Y GAUGE event float 0~60*Period*100
0
ConnReEstabT
imeTot/ConnRe
EstabTimeCnt
sum
(ConnReEstabTimeTot)/
sum
(ConnReEstabTimeCnt)
ConnReEstab
TimeMax
ms Maximum RRC
connection
reestablishment setup
time
Y GAUGE event float 0~60*Period*100
0
- max
(ConnReEstabTimeMax)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 60 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
ConnReEstab
TimeTot
ms Sum of
ConnReEstabTime
collected
Y GAUGE event float 0~3.4*10^38 - -
ConnReEstab
TimeCnt
count Collected
ConnReEstabTime
count
- GAUGE event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 61 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 7. Collection Time for RRC Connection Reestablishment Time
The RRC Connection setup time is a time taken from receiving the RRC Connection Request message up to receive in the RRC Conn
ection Setup Complete message.
The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Rrc Connection Reestablishment Request
Rrc Connection Reestablishment
Rrc Connection Reestablishment Complete
RRC Connection Resetup time
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 62 of 427
2600-00FET7GAT 6.0
3.8 Call Drop
Call drop statistics are calculated for successfully connected calls but abnormally dropped due to eNB failure or by the MME.
They are identified by the RRC connection establishment cause informed by the UE. Successful call connection indicates that the defau
lt bearer setup is successful or incoming handover is successful for a call. Calls released by the eNB due to user inactivity, normally r
eleased by the MME, and released by the UE duplication are not considered abnormally terminated.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 63 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CallDrop_ECCB_DSP_
AUDIT_RLC_MAC_CA
LL_RELEASE
count A call is released due to the
resource mismatch, because
the ECCB has remaining calls
but the RLC and the MAC have
no call remaining.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_RCV_
RESET_REQUEST_F
ROM_ECMB
count A call is released due to
receiving a reset request from
the ECMB block due to refork
of a specific block in eNB.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_RCV_
CELL_RELEASE_IND_
FROM_ECMB
count A call is released due to the
Cell Release Ind message
received from the ECMB block
because of DSP down or CPRI
failure caused by DSP
problem.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_RADI
O_LINK_FAILURE
count A call is released due to radio
link fail.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_DSP_
AUDIT_MAC_CALL_R
ELEASE
count A call is released due to the
resource mismatch, because
the ECCB and the RLC have
remaining calls but the MAC
has no call remaining.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_ARQ_
MAX_RE_TRANSMISS
ION
count A call is released when ARQ
ACK is not received from the
UE after the RLC performs
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 64 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
transmission as many as the
Max Retransmission to the UE.
CallDrop_ECCB_DSP_
AUDIT_RLC_CALL_RE
LEASE
count A call is released due to the
resource mismatch, because
the ECCB and the MAC have
remaining calls but the RLC
has no call remaining.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_TMO
UT_rrcConnectionReco
nfig
count A call is released when the
RRC Connection
Reconfiguration Complete
message is not received from
the UE after transmitting the
RRC Connection
Reconfiguration message.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_TMO
UT_rrcConnectionReEs
tablish
count A call is released when the
RRC Connection
Reestablishment Complete
message is not received from
the UE after transmitting the
RRC Connection
Reestablishment message to
the UE.
Y CC event int 0-2147483647 - -
CallDrop_ECCB_S1_S
CTP_OUT_OF_SERVI
CE
count A call is released when the S1
Association’s status is changed
from In Service to Out of
Service state.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 65 of 427
2600-00FET7GAT 6.0
4 ERAB
4.1 E-RAB Setup
This section provides statistics data for the default bearer setup to activate the initial DRB’s radio and S1 bearer.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EstabInitAttNbr count ERAB setup attempt count. Y CC event int 0-2147483647 - -
EstabInitSuccNbr count ERAB setup success count. Y CC event int 0-2147483647 - -
ErabInitFailNbr_CP
_CC_TO
count A call is released due to call
control timeout in the protocol
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 66 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
blocks (MAC, RLC, PDCP, GTP)
during ERAB setup.
ErabInitFailNbr_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
during ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_UP
_GTP_FAIL
count A call is released due to the
failure in the GTP block during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_UP
_MAC_FAIL
count A call is released due to the
failure in the MAC block during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_UP
_PDCP_FAIL
count A call is released due to the
failure in the PDCP block during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_UP
_RLC_FAIL
count A call is released due to the
failure in the RLC block during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_RR
C_SIG_FAIL
count A call is released due to
receiving RRC signaling during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_RR
C_SIG_TO
count A call is released due to ERAB
uplink message timeout (not
received) during ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_CP count A call is released due to Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 67 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
_BH_CAC_FAIL insufficient backhaul-based eNB
resources during ERAB setup.
ErabInitFailNbr_CP
_CAPA_CAC_FAIL
count A call is released due to
insufficient capacity-based eNB
resources during ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_CP
_QOS_CAC_FAIL
count A call is released due to
insufficient QoS-based eNB
resources during ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_S1
AP_CU_FAIL
count A call is released due to the
S1AP specification cause during
ERAB setup.
Y CC event int 0-2147483647 - -
ErabInitFailNbr_S1
AP_LINK_FAIL
count A call is released due to S1
SCTP link failure during ERAB
setup
Y CC event int 0-2147483647 - -
ErabInitFailNbr_S1
AP_SIG_FAIL
count A call is released due to
receiving S1AP signaling during
ERAB setup.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 68 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 8. Collection Time for E-RAB Setup
For E-RAB setup count statistics, Attempt is counted when the Initial Context Setup Request message is received during the initial call
setup. Success is counted when the Initial Context Setup Response message is transmitted. A failure is counted when a timeout or fai
lure occurs during the procedure and the applicable cause value is recorded.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
Security Mode Command
Security Mode Complete
Rrc Connection Reconfiguration
Rrc Connection Reconfiguration Complete
Initial Context Setup Response
1 Attempt
2 Success
Authentication Procedure (NAS)
Initial Context Setup Request
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 69 of 427
2600-00FET7GAT 6.0
4.2 E-RAB Setup Add
This section provides statistics data for the number of additional E-RAB (dedicated bearer) setups by the MME following the initial de
fault bearer setup.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EstabAddAttNbr count The number of attempts for
additional ERAB setup
Y CC event int 0-2147483647 - -
EstabAddSuccNbr count The number of successes for
additional ERAB setup
Y CC event int 0-2147483647 - -
ErabAddFailNbr_CP
_CC_TO
count A call is released due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during
additional ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
during additional ERAB setup.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 70 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ErabAddFailNbr_UP
_GTP_FAIL
count A call is released due to the failure
in the GTP block during additional
ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_UP
_MAC_FAIL
count A call is released due to the failure
in the MAC block during additional
ERAB setup.
Y CC event int 0-214743647 - -
ErabAddFailNbr_UP
_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during
additional ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_UP
_RLC_FAIL
count A call is released due to the failure
in the RLC block during additional
ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_RR
C_SIG_FAIL
count A call is released due to receiving
RRC signaling during additional
ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_RR
C_SIG_TO
count A call is released due to ERAB
uplink message timeout (not
received) during additional RRC
setup
Y CC event int 0-2147483647 - -
ErabAddFailNbr_CP
_BH_CAC_FAIL
count A call is released due to insufficient
backhaul-based eNB resources
during additional ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_CP
_CAPA_CAC_FAIL
count A call is released due to insufficient
capacity-based eNB resources
during additional ERAB setup.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 71 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ErabAddFailNbr_CP
_QOS_CAC_FAIL
count A call is released due to insufficient
QoS-based eNB resources during
additional ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_S1
AP_CU_FAIL
count A call is released due to the S1AP
specification cause during
additional ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_S1
AP_LINK_FAIL
count A call is released due to S1 SCTP
link failure during additional ERAB
setup
Y CC event int 0-2147483647 - -
ErabAddFailNbr_S1
AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during additional
ERAB setup.
Y CC event int 0-2147483647 - -
ErabAddFailNbr_CP_
CC_INTERACTION
count A failure occurs due to ERAB
Setup request from the MME
during inter eNB handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 72 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 9. Collection Time for E-RAB Setup Add
For additional E-RAB setup count statistics, Attempt is counted when the E-RAB Setup Request message is received during the additio
nal E-RAB setup. Success is counted when the E-RAB Setup Response message is transmitted. A failure is counted when a timeout or
failure occurs during the procedure and the applicable cause value is recorded.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
Rrc Connection Reconfiguration
E-RAB Setup Response
E-RAB Setup Request
Rrc Connection Reconfiguration Complete
2 Success
1 Attempt
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 73 of 427
2600-00FET7GAT 6.0
4.3 E-RAB Setup Time
This section provides statistics data for the average E-RAB Setup time and the maximum E-RAB Setup time.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EstabTime ms Average E-RAB setup time Y GAUGE event int 0-60*Period*1000 EstabTimeTot/Est
abTimeCnt
sum (EstabTimeTot)/
sum (EstabTimeCnt)
EstabTimeMax ms Maximum E-RAB setup time Y GAUGE event int 0-60*Period*1000 - max
(EstabTimeMax)
EstabTimeTot ms Sum of EstabTime collected Y GAUGE event int 0-2147483647 - -
EstabTimeCnt count Number of EstabTime
events collected
Y GAUGE event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 74 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 10. Collection Time for E-RAB Setup Time
The E-RAB setup time indicates the duration from receiving the Initial Context Setup Request message up to transmitting the Initial C
ontext Setup Response, which is reported in milliseconds. The statistics block calculates the average and maximum values of the setup
time during the collection period.
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Security Mode Complete
RRC Connection Reconfiguration
RRC Connection Reconfiguration Complete
Initial Context Setup Response
E-RAB Setup time
Initial Context Setup Request
Security Mode Command
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 75 of 427
2600-00FET7GAT 6.0
4.4 eNB E-RAB Erase Request
This section provides statistics data for the E-RAB release requests made by the eNB by transmitting the UE Context Release Request
message.
Index
Name Range Description
cNum 0~2 Serving Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EraseAttbyEnb_
CP_CC_TO
count A call is released due to the call control
timeout of the protocol block (MAC,
RLC, PDCP, GTP) when an eNB-
initiated UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
CP_CC_FAIL
count A call is released due to reset notification
(eNB failure or block restart) from ECMB
when an eNB-initiated UE Context
Release occurs or by the ECCB block.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
UP_GTP_FAIL
count A call is released due to internal failure
of the GTP block when an eNB-initiated
UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
UP_MAC_FAIL
count A call is released due to internal failure
of the MAC block when an eNB-initiated
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 76 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UE Context Release occurs.
EraseAttbyEnb_
UP_MAC_UE_I
NACT
count A call is released due to UE inactivity in
eNB when an eNB-initiated UE Context
Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
UP_PDCP_FAI
L
count A call is released due to internal failure
of the PDCP block when an eNB-
initiated UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
UP_RLC_FAIL
count A call is released due to internal failure
of the RLC block when an eNB-initiated
UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
RRC_HC_TO
count A call is released due to HO command
timeout (not received) when an eNB-
initiated UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
RRC_SIG_FAIL
count A call is released due to receiving RRC
signaling when an eNB-initiated UE
Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
RRC_SIG_TO
count A call is released due to S1AP signaling
timeout (not received) when an eNB-
initiated UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
S1AP_CU_FAIL
cont A call is released due to the S1AP
specification cause occurred when an
eNB-initiated UE Context Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_
S1AP_RO_TO
count A call is released due to S1AP
RelocOverall timeout (not received)
when an eNB-initiated UE Context
Release occurs.
Y CC event int 0-2147483647 - -
EraseAttbyEnb_ count A call is released due to S1AP signaling Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 77 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1AP_SIG_TO timeout (not received) when an eNB-
initiated UE Context Release occurs.
EraseAttbyEnb_
X2AP_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not received)
when an eNB-initiated UE Context
Release occurs.
Y CC event int 0-2147483647 - -
Collection Time
Figure 11. Collection Time for eNB E-RAB Erase Request
The eNB E-RAB erase request refers to deleting the UE context. When the eNB needs to release the UE context, it transmits the UE
Context Release Request message to the MME, and counts statistics.
eNB UE
MME S/GW
RRC_CONNECTED
RRC_CONNECTED
RRC Connection Release
UE Context Release Complete
UE Context Release Request 1 Count
UE Context Release Command
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 78 of 427
2600-00FET7GAT 6.0
4.5 E-RAB Erase
This section provides statistics data for the E-RAB release requests made by the eNB using the UE Context Release command.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EraseAtt count The number of the E-RAB release
attempts using the UE Context
Release command.
Y CC event int 0-2147483647 - -
EraseSucc count The number of the E-RAB release
successes using the UE Context
Release command.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 79 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 12. Collection Time for E-RAB Erase
For E-RAB ERASE statistics, attempt is counted when the UE Context Release Command is received from the MME. Success is coun
ted when the UE Context Release Complete message is transmitted.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
1 Attempt UE Context Release Command
UE Context Release Complete
Rrc Connection Release
2 Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 80 of 427
2600-00FET7GAT 6.0
4.6 E-RAB Modify
This section provides statistics data for the E-RAB Modify count.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ModQoSAttNbr count The number of ERAB Modify
attempts.
Y CC event int 0-2147483647 - -
ModQoSSuccNbr count The number of ERAB Modify
successes.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
CP_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
CP_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
block during ERAB Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_ count A call is released due to the failure Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 81 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UP_GTP_FAIL in the GTP block during ERAB
Modify.
ModQoSFailNbr_
UP_MAC_FAIL
count A call is released due to the failure
in the MAC block during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
UP_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
UP_RLC_FAIL
count A call is released due to the failure
in the RLC block during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during ERAB Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
RRC_SIG_TO
count A call is released due to ERAB
uplink message timeout (not
received) during RRC Modify
procedure
Y CC event int 0-2147483647 - -
ModQoSFailNbr_C
P_BH_CAC_FAIL
count A call is released due to insufficient
backhaul-based eNB resources
during ERAB Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
CP_CAPA_CAC_
FAIL
count A call is released due to insufficient
capacity-based eNB resources
during ERAB Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
CP_QOS_CAC_F
count A call is released due to insufficient
QoS-based eNB resources during
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 82 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AIL ERAB Modify.
ModQoSFailNbr_
S1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
S1AP_LINK_FAIL
count A call is released due to S1 SCTP
link failure during ERAB Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
S1AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during ERAB
Modify.
Y CC event int 0-2147483647 - -
ModQoSFailNbr_
CP_CC_INTERA
CTION
count A failure occurs due to ERAB
Modify request from the MME
during inter eNB handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 83 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 13. Collection Time for E-RAB Modify
For E-RAB Modify statistics, Attempt is counted when the E-RAB Modify Request message is received from the MME, and Success i
s counted when the E-RAB Modify Response message is transmitted. A failure is counted when the E-RAB Modify procedure fails du
e to an internal timeout or failure, and the applicable cause value is recorded.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
1 Attempt E-RAB Modify Request
E-RAB Modify Response
Rrc Connection Reconfiguration
2 Success
Rrc Connection Reconfiguration Complete
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 84 of 427
2600-00FET7GAT 6.0
4.7 eNB E-RAB Release Request
This section provides statistics data for the E-RAB release requests made by the eNB using the E-RAB Release Indication message.
E-RAB release request usually occurs when only a specific bearer is released while two or more bearers are set up.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RelAttbyEnbN
br_CP_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during eNB-
initiated ERAB release.
Y CC event int 0-2147483647 - -
RelAttbyEnbN
br_S1AP_CU_
FAIL
count Release due the S1AP specification
cause during eNB-initiated ERAB
release.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 85 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 14. Collection Time for eNB E-RAB Erase Request
The eNB E-RAB Release statistics are counted when the eNB deletes the applicable bearers as needed and transmits the E-RAB Relea
se Indication message to the MME.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
1 Count E-RAB Release Indication
E-RAB Release Response
Rrc Connection Reconfiguration
Rrc Connection Reconfiguration Complete
E-RAB Release Command
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 86 of 427
2600-00FET7GAT 6.0
4.8 E-RAB Release
This section provides statistics data for the E-RAB releases made by the eNB using the E-RAB Release Command.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RelAttNbr count Attempt count for E-RAB release by the
ERAB Release command
Y CC event int 0-2147483647 - -
RelSuccNbr count Success count for E-RAB release by the
ERAB Release command
Y CC event int 0-2147483647 - -
RelFailNbr_C
P_CC_FAIL
count A call is released due to reset notification
(eNB failure or block restart) from ECMB or
by ECCB block during MME-initiated ERAB
release.
Y CC event int 0-2147483647 - -
RelFailNbr_S1
AP_SIG_FAIL
count A call is released due to receiving S1AP
signaling during MME-initiated ERAB
release.
Y CC event int 0-2147483647 - -
RelFailNbr_S1
AP_CU_FAIL
count A call is released due to S1AP specification
cause during MME-initiated ERAB release.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 87 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RelActive count Number of active E-RABs, for which a call is
released due to abnormal operation in eNB.
Y CC event int 0-2147483647 - -
RelFailNbr_C
P_CC_INTER
ACTION
count A failure occurs due to ERAB Release
request from the MME during inter eNB
handover
Y CC event int 0-2147483647 - -
Collection Time
Figure 15. Collection Time for E-RAB Release
For E-RAB release statistics, Attempt is counted when the E-RAB Release Request message is received from the MME. Success is co
unted when the E-RAB Release Response message is transmitted. If a failure is counted when the E-RAB Release procedure fails due
to an internal timeout or failure, and the applicable cause value is recorded.
eNB UE MME S/GW
RRC_CONNECTED
RRC_CONNECTED
1 Attempt E-RAB Release Command
E-RAB Release Response
Rrc Connection Reconfiguration
2 Success
Rrc Connection Reconfiguration Complete
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 88 of 427
2600-00FET7GAT 6.0
4.9 E-RAB Activity (UE)
This section provides statistics data for the in-session time of the UE. In-session is defined as valid if a data transmission took place
during the last 100 ms; it collects the in-session time of the UE which had data transmissions with the PDSCH/PUSCH during the stat
istics period.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
SessionTime
UE
ms Average in-session time per
UE
Y SI 5.12 s. float 0-60*Period*
1000
SessionTimeUETot)/
SessionTimeUECnt
sum
(SessionTimeUETot)/
sum
(SessionTimeUECnt)
SessionTime
UETot
ms Sum of SessionTimeUE
collected
Y SI 5.12 s. float 0-3.4*10^38 - -
SessionTime
UECnt
count Collected SessionTimeUE
count
SI 5.12 s int 0~2147483647 - -
Collection Time
TTI
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 89 of 427
2600-00FET7GAT 6.0
4.10 E-RAB Activity (QCI)
This section provides statistics data for the in-session time per QCI. In-session is defined as valid if a data transmission took place dur
ing the last 100 ms; it collects the in-session time of the Bearer which had data transmissions with the PDSCH/PUSCH during the stat
istics period for each QCI.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
SessionTimeQ
CI
ms Average in-session time
per QCI
Y SI 5.12 s. float 0-
60*Period*
1000
SessionTimeQ
CITot/SessionT
imeQCICnt
sum (SessionTimeQCITot)/
sum (SessionTimeQCICnt)
SessionTimeQ
CITot
ms Sum of SessionTimeQCI
collected
Y SI 5.12 s. float 0-
3.4*10^38
- -
SessionTimeQ
CICnt
count Collected SessionTimeQCI
count
- SI 5.12sec int 0~2147483
647
- -
Collection Time
TTI
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 90 of 427
2600-00FET7GAT 6.0
4.11 E-RAB Simultaneous Number
This section provides statistics data for the average E-RAB count and the maximum E-RAB count per unit time.
Index
Name Range Description
cNum 0~2 Cell Index
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UsageNbr count Average E-RAB count per
unit time.
Y GAUGE 2 s. float 0-3.4*10^38 UsageNbrTot/
UsageNbrCnt
sum
(UsageNbrTot)/
sum
(UsageNbrCnt)
UsageNbrMax count Maximum E-RAB count per
unit time.
Y GAUGE 2 s. float 0-3.4*10^38 - max
(UsageNbrMax)
UsageNbrTot count The sum of collected
UsageNbr
- GAUGE 2 s float 0~3.4*10^38 - -
UsageNbrCnt count Collected UsageNbr count - GAUGE 2 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 91 of 427
2600-00FET7GAT 6.0
5 Handover (HO) EUTRAN The statistics on handovers are collected for intra LTE handover and inter RAT han
dover respectively. Intra LTE handover includes intra eNB, inter eNB S1, and inter
eNB X2 handovers. Inter RAT handover includes inter RAT optimized HRPD and i
nter RAT UTRAN handovers.
Intra-LTE handover statistics are based on the source and target cells, which are col
lected through the respective source and target eNBs. Inter-RAT handover statistics
are based on the eNB’s served cells.
Intra eNB Handover
This section provides statistics data for handovers between cells within the eNB. Int
ra eNB handover is performed when the UE moves between the cells that belong t
o the same eNB.
The following figure illustrates this procedure.
Figure 16. Intra eNB Handover Statistics Processing
Steps Description
1) Intra eNB handover is determined based on the measurement report.
2) New RLC, MAC and PHY configurations are set for the target cell.
3) When the resource setup is completed in the target cell, the RRC Connection
Reconfiguration message is transmitted to instruct the UE to perform handover.
4) The RRC Connection Reconfiguration Complete message is received to complete the
intra handover successfully.
(mobilityControlinfo)
3) RRCConnection-Reconfiguration
HO attempt
UE Source cell Target cell
1) MeasurementReport
2) Target Cell Preparation
4) RRCConnectionReconfigurationComplete
HO preparation
HO success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 92 of 427
2600-00FET7GAT 6.0
X2 Handover
When the UE moves between cells of different eNBs that belong to the same MM
E group, handover is performed via the X2 interface. Upon performing the X2 han
dover, the source provides the statistics on outgoing handover; and the target provid
es statistics for incoming.
The procedure of collecting Attempt, Preparation, and Success statistics is shown in
the following figure.
Figure 17. X2-based Handover Statistics Processing
HO attempt
HO Preparation
HO Success
UE Source eNB MME S-GW
EPC
1) MeasurementReport
Target eNB
Downlink/Uplink data Downlink/Uplink data
3) HANDOVER REQUEST ACKNOWLEDGE
5) SN STATUS TRANSFER
4) RRCConnection- Reconfiguration
(mobilityControlinfo)
Data forwarding
6) Synchronization/UL allocation and timing advance
7) RRCConnectionReconfigurationComplete
Forwarded data
Uplink data
Forwarded data
Downlink data
Down/Uplink data Down/Uplink data
Uplink data
Downlink data
8) PATH SWITCH REQUEST
End marker
End marker
11) PATH SWITCH
REQUEST
ACKNOWLEDGE 12) UE CONTEXT RELEASE
2) HANDOVER REQUEST
9) Modify Bearer Request
10) Modify Bearer Response
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 93 of 427
2600-00FET7GAT 6.0
Step Description
1) The UE transmits the MeasurementReport message according to the system
information, standards and rules.
The source eNB determines whether to perform the UE handover based on the
MeasurementReport message and the radio resource management information.
2) The source eNB sends the target eNB a HANDOVER REQUEST message containing
the information required for handover. The target eNB can perform management control
in accordance with the E-RAB QoS information received.
3)-4) The target eNB creates the RRCConnectionReconfiguration message which contains
the mobileControlInfo IE for preparing and executing the handover. The target eNB
transmits RRCConnectionReconfiguration to the source eNB, which is encapsulated in
the HANDOVER REQUEST ACKNOWLEDGE message. The source eNB transmits the
RRCConnectionReconfiguration message and the necessary parameters to the UE to
command it to perform the handover.
5) To transmit the uplink PDCP SN receiver status and the downlink PDCP SN transmitter
status of the E-RABs of which the PDCP status must be preserved, the source eNB
transmits the SN STATUS TRANSFER message to the target eNB.
6) After receiving the RRCConnectionReconfiguration message that encapsulates the
mobileControlInfo IE, the UE performs synchronization with the target eNB and
accesses the target cell via the Random Access CHannel (RACH). The target eNB
responds with UL allocation and a timing advance value.
7) After having connected to the target cell successfully, the UE notifies the target eNB that
the Handover procedure has been completed using an RRCConnection-
ReconfigurationComplete message.
8) The target eNB, using the PATH SWITCH REQUEST message, notifies the MME that
the UE has changed the cell.
9)-10) The MME sends the Modify Bearer Request message to the S-GW. The S-GW changes
the downlink data path into the target eNB. The S-GW transmits at least one ‘end
marker’ to the source eNB through the previous path, and releases the user plane
resources for the source eNB.
The S-GW transmits a Modify Bearer Response message to the MME.
11) The MME transmits the PATH SWITCH REQUEST ACKNOWLEDGE message to
acknowledge the PATH SWITCH REQUEST message
12) The target eNB sends the UE CONTEXT RELEASE message to the source eNB to
notify the handover has succeeded and to make the source eNB release its resources.
If the source eNB receives the UE CONTEXT RELEASE message, it release the radio
resources and the control plane resources related to the UE context.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 94 of 427
2600-00FET7GAT 6.0
S1 Handover
Generally, when two eNBs belong to the same MME group, handover is performed
via the X2 interface, and if two eNBs belong to different MME groups, handover
is performed via the S1 interface. However, if they belong to the same MME, but
there is no X2 interface between the two eNBs or there is X2 link failure, handove
r is performed via the S1 interface.
Upon performing the S1 handover, the source provides the statistics on outgoing ha
ndover; and the target provides statistics for the incoming handover.
The procedure of collecting Attempt, Preparation, and Success statistics is shown be
low.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 95 of 427
2600-00FET7GAT 6.0
Figure 18. S1-based Handover Procedure
HO attempt
HO Preparation
HO attempt
Ho Preparation
Ho Success
UE Source eNB MME S-GW
EPC
Target eNB
Downlink/Uplink data Downlink/Uplink data
3) HANDOVER REQUEST
5) Create Indirect Data
Forwarding Tunnel Request
1) Direct data forwarding
1) Decision to trigger a relocation via S1
2) HANDOVER REQUIRED
Indirect data forwarding
Downlink data
Downlink data
End marker
End marker
6) Create Indirect Data
Forwarding Tunnel Response 7) HANDOVER COMMAND
9) eNB STATUS TRANSFER
10) MME STATUS TRANSFER
2) Indirect data forwarding
11) Detach from old cell/Synchronize to new cell
12) RRCConnectionReconfigurationComplete
Forwarded data
Uplink data Uplink data
13) HANDOVER NOTIFY 14) Modify Bearer Request
15) Modify Bearer Response
Forwarded data
16) Tracking Area Update procedure
17) UE CONTEXT RELEASE COMMAND
18) UE CONTEXT RELEASE COMPLETE 19) Delete Indirect Data
Forwarding Tunnel Request
20) Delete Indirect Data
Forwarding Tunnel Response
Downlink/Uplink data Downlink/Uplink data
4) HANDOVER REQUEST
ACKNOWLEDGE
8) RRCConnection- Reconfiguration
(mobilityControlinfo)
Ho Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 96 of 427
2600-00FET7GAT 6.0
Step Description
1) The source eNB determines whether to perform S1-based handover into the target
eNB. The source eNB can make this decision when there is no X2 connection to the
target or when an error is notified by the target eNB after an X2-based handover has
failed, or based on the information the source eNB has obtained dynamically.
2) The source eNB transmits the HANDOVER REQUIRED message to the MME.
The source eNB notifies the target eNB which bearer is used for data forwarding and
whether forwarding can be made directly from the source eNB to the target eNB.
3)-4) The MME transmits the HANDOVER REQUEST message to the target eNB.
This message makes the target eNB create a UE context containing the bearer-related
information and the security context.
The target eNB transmits the HANDOVER REQUEST ACKNOWLEDGE message to
the MME.
5)-6) If indirect forwarding is used, the MME sends the Create Indirect Data Forwarding
Tunnel Request message to the S-GW. The S-GW replies the MME with the Create
Indirect Data Forwarding Tunnel Response message.
7)-8) The MME sends the HANDOVER COMMAND message to the source eNB. The source
eNB creates the RRCConnectionReconfiguration message using the Target to Source
Transparent Container IE encapsulated in the HANDOVER COMMAND message and
then transmits it to the UE.
9)-10) To transmit the PDCP and HFN status of the E-RABs of which the PDCP status must be
preserved, the source eNB transmits the eNB/MME STATUS TRANSFER message to
the target eNB via the MME. The source eNB must start forwarding the downlink data to
the target eNB through the bearer which was determined to be used for data
forwarding. This can be either direct or indirect forwarding.
11) The UE performs synchronization with the target eNB and connects to the target cell via
a RACH.
The target eNB responds with UL allocation and a timing advance value.
12) After having synchronized with the target cell, the UE notifies the target eNB that the
Handover procedure has been completed using the
RRCConnectionReconfigurationComplete message. The downlink packets forwarded
from the source eNB can be transmitted to the UE.
The uplink packets can also be transmitted from the UE to the S-GW via the target eNB.
13) The target eNB sends the HANDOVER NOTIFY message to the MME. The MME starts
the timer which tells when the resources of the source eNB and the temporary
resources used by the S-GW for indirect forwarding will be released.
14) The MME transmits the Modify Bearer Request message for each PDN connection to
the S-GW.
Downlink packets are transmitted from the S-GW to the target eNB immediately.
15) The S-GW transmits a Modify Bearer Response message to the MME. As soon as the
target eNB changes the path to help packet reordering, the S-GW transmits at least one
‘end marker’ packet to the source eNB through the previous path.
16) If any of the conditions listed in section 5.3.3.0 of TS 23.401 (6) are met, the UE starts
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 97 of 427
2600-00FET7GAT 6.0
Step Description
the Tracking Area Update procedure.
17)-18) When the timer started at step 13) expires, the MME sends the UE CONTEXT
RELEASE COMMAND message to the source eNB. The source eNB releases the
resources related to the UE and replies with the UE CONTEXT RELEASE COMPLETE
message.
19)-20) If indirect forwarding has been used, when the timer started at Step 13 expires the MME
transmits the Delete Indirect Data Forwarding Tunnel Request message to the S-GW.
This message gets the S-GW to release the temporary resources allocated for indirect
forwarding at Step 5).
The S-GW responds to the MME with the Delete Indirect Data Forwarding Tunnel
Response message.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 98 of 427
2600-00FET7GAT 6.0
5.1 Intra eNB Handover
This section provides statistics data for handovers between cells within the eNB.
Index
Name Range Description
cNum 0~2 Source Cell Index
tcId 0~268435455 Target Cell Index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IntraEnbAtt count Intra-handover attempt count. Y CC event int 0-2147483647 - -
IntraEnbPrepSucc count Intra-handover preparation success
count.
Y CC event int 0-2147483647 - -
IntraEnbSucc count Intra-handover execution success
count.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
CP_CC_TO
count Preparation fails due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during
the intra handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 99 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
restart) from ECMB or by the
ECCB block during the intra
handover preparation.
IntraEnbPrepFail_
UP_MAC_FAIL
count Preparation fails due to internal
failure in the MAC block during the
intra handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
UP_RLC_FAIL
count Preparation fails due to internal
failure in the RLC block during the
intra handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the intra
handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
CP_BH_CAC_FAI
L
count Preparation fails due to insufficient
backhaul-based eNB resources
during the intra handover
preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
CP_CAPA_CAC_
FAIL
count Preparation fails due to insufficient
capacity-based eNB resources
during the intra handover
preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
CP_QOS_CAC_F
AIL
count Preparation fails due to insufficient
QoS-based eNB resources during
the intra handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during the intra
handover preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 100 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IntraEnbPrepFail_
S1AP_LINK_FAIL
count Preparation fails due to S1 SCTP
link failure during the intra
handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbPrepFail_
S1AP_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the intra
handover preparation.
Y CC event int 0-2147483647 - -
IntraEnbFail_CP_
CC_TO
count A call is released due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during
the intra handover execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_CP_
CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the intra
handover execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_UP_
GTP_FAIL
count A call is released due to the
internal failure in the GTP block
during the intra handover
execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_UP_
MAC_FAIL
count A call is released due to the
internal failure in the MAC block
during the intra handover
execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_UP_
RLC_FAIL
count A call is released due to the
internal failure in the RLC block
during the intra handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 101 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
execution.
IntraEnbFail_RR
C_HC_TO
count A call is released due to HO
command timeout (not received)
during the intra handover
execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_RR
C_SIG_FAIL
count A call is released due to receiving
RRC signaling during the intra
handover execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_S1A
P_CU_FAIL
count A call is released due to the S1AP
specification cause during the intra
handover execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_S1A
P_LINK_FAIL
count A call is released due to S1 SCTP
link failure during the intra
handover execution.
Y CC event int 0-2147483647 - -
IntraEnbFail_S1A
P_SIG_FAIL
count A call is released due to S1AP
signaling timeout (not received)
during the intra handover execution.
Y CC event int 0-2147483647 - -
IntraEnbCnt count Intra-eNB handover collection
count
CC event int 0~2147483647 - -
IntraEnbNbrCid tcID tcID of which collection is
requested
OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 102 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 19. Collection Time for Intra eNB Handover
For intra-handover statistics, Attempt is counted when an intra-handover is decided after the Measurement Report message arrival, and
Prepare is counted when the intra-handover preparation is complete and at the time of transmitting the RRC Connection Reconfiguratio
n message to the UE. Success is counted when the target cell successfully receives the RRC Connection Reconfiguration Complete mes
sage from the UE.
If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai
ls, it is counted as Intra Fail, returning the cause value.
eNB
UE
UE moves to Intra eNB Cell
Rrc Connection Reconfiguration
Rrc Connection Reconfiguration Complete
Attempt
Prepare
Measurement Report
Success
HO Decision
Target Cell Preparation
Internal Path Switch
1
2
3
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 103 of 427
2600-00FET7GAT 6.0
5.2 X2 Handover Out
This section provides statistics data for X2 handover between eNBs in reference with the source eNB.
Index
Name Range Description
cNum 0~2 Source Cell Index
tcId 0-268435455 Target Cell Index
HOCause 0-1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterX2OutAtt count Attempt count for X2 handover from
SeNB.
Y CC event int 0-2147483647 - -
InterX2OutPrepSu
cc
count Success count for X2 handover
preparation from SeNB.
Y CC event int 0-2147483647 - -
InterX2OutSucc count Success count for X2 handover
execution from SeNB.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
block during the inter X2 handover
preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 104 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterX2OutPrepFail
_S1AP_LINK_FAIL
count Preparation fails due to S1 SCTP
link failure during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_S1AP_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_X2AP_CU_FAIL
count Preparation fails due to X2AP
specification cause during the inter
X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_X2AP_LINK_FAIL
count Preparation fails due to X2 SCTP
link failure during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_X2AP_RP_TO
count Preparation fails due to X2AP
relocprep timeout (not received)
during the inter X2 handover
preparation.
Y CC event int 0-2147483647 - -
InterX2OutPrepFail
_X2AP_SIG_FAIL
count Preparation fails due to receiving
X2AP signaling during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2OutFail_CP
_CC_TO
count A call is released due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 105 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
block during the inter X2 handover
execution.
InterX2OutFail_UP
_GTP_FAIL
count A call is released due to the failure
in the GTP block during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_UP
_MAC_FAIL
count A call is released due to the internal
failure in the MAC block during the
inter X2 handover execution.
Y CC event int 0-214783647 - -
InterX2OutFail_UP
_PDCP_FAIL
count A call is released due to the internal
failure in the PDCP block during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_UP
_RLC_FAIL
count A call is released due to the internal
failure in the RLC block during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_
S1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_S1
AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_S1
AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the inter X2
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 106 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover execution.
InterX2OutFail_X2
AP_CU_FAIL
count A call is released due to the X2AP
specification cause during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_X2
AP_LINK_FAIL
count A call is released due to the X2
SCTP link failure during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_X2
AP_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not received)
during the inter X2 handover
execution.
Y CC event int 0-2147483647 - -
InterX2OutFail_X2
AP_SIG_FAIL
count A call is released due to receiving
the X2AP signaling during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2OutCnt count X2 Handover Out collection count - CC event int 0~214748364
7
- -
InterX2OutCid tcID tcID of which collection is requested - OW event int 0~214748364
7
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 107 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 20. Collection Time for X2 Handover Out
UE MME S/GW
Rrc Connection
Reconfiguration
Handover Request
Target eNB
Measurement Report
Source eNB
HO Decision
Handover Request
Acknowledge
SN Status Transfer
Path Switch Request
Path Switch Request
Acknowledge Release Request
Call Release
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
1 Attempt
2 Prepare
3 Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 108 of 427
2600-00FET7GAT 6.0
For Inter X2 Handover Out statistics, Attempt is counted when the X2 Handover Request message is transmitted to the target eNB aft
er the inter X2 handover decision following the Measurement Report message arrival. Prepare is counted when the X2 Handover Reque
st Acknowledge message is received from the target eNB. The source eNB transmits the RRC Connection Reconfiguration message to t
he UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE.
The target eNB transmits the X2 UE Context Release message to the source eNB when the handover is successfully completed. At thi
s point, the source eNB is counted as Success. If the procedure from to fails, it is counted as Prepare Fail, returning the cause
value, and when the procedure from to fails, it is counted as Inter X2 Fail, returning the cause value.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 109 of 427
2600-00FET7GAT 6.0
5.3 X2 Handover In
This section provides statistics data for X2 handover between eNBs in reference with the target eNB.
Index
Name Range Description
cNum 0~2 Target Cell Index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterX2InAtt count The number of attempts for X2
handover in TeNB
Y CC event int 0-2147483647 - -
InterX2InPrepSu
cc
count The number of successes for X2
handover preparation in TeNB
Y CC event int 0-2147483647 - -
InterX2InSucc count The number of successes for X2
handover execution in TeNB
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_CP_CC_TO
count Preparation fails due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the inter
X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 110 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
restart) from ECMB or by ECCB
block during the inter X2 handover
preparation.
InterX2InPrepFai
l_UP_GTP_FAIL
count Preparation fails due to internal
failure in the GTP block during the
inter X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_UP_MAC_FAIL
count Preparation fails due to internal
failure in the MAC block during the
inter X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_UP_PDCP_FAI
L
count Preparation fails due to internal
failure in the PDCP block during the
inter X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_UP_RLC_FAIL
count Preparation fails due to internal
failure in the RLC block during the
inter X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_CP_BH_CAC_
FAIL
count Preparation fails due to insufficient
backhaul-based eNB resources
during the inter X2 handover
preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_CP_CAPA_CA
C_FAIL
count Preparation fails due to insufficient
capacity-based eNB resources
during the inter X2 handover
preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_CP_QOS_CAC
_FAIL
count Preparation fails due to insufficient
QoS-based eNB resources during
the inter X2 handover preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 111 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterX2InPrepFai
l_S1AP_LINK_F
AIL
count Preparation fails due to S1 SCTP
link failure during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_S1AP_SIG_FA
IL
count Preparation fails due to receiving
S1AP signaling during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFail
_X2AP_CU_FAIL
count Preparation fails due to X2AP
specification cause during the inter
X2 handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_X2AP_LINK_F
AIL
count Preparation fails due to X2 SCTP
link failure during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2InPrepFai
l_X2AP_SIG_FA
IL
count Preparation fails due to receiving
X2AP signaling during the inter X2
handover preparation.
Y CC event int 0-2147483647 - -
InterX2InFail_CP
_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
block during the inter X2 handover
execution.
Y CC event int 0-2147483647 - -
InterX2InFail_UP
_GTP_FAIL
count A call is released due to the failure in
the GTP block during the inter X2
Y CC event int 0-217483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 112 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover execution.
InterX2InFail_UP
_MAC_FAIL
count A call is released due to the internal
failure in the MAC block during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_UP
_PDCP_FAIL
count A call is released due to the internal
failure in the PDCP block during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_UP
_RLC_FAIL
count A call is released due to the internal
failure in the RLC block during the
inter X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_R
RC_HC_TO
count A call is released due to HO
command timeout (not received)
during the inter X2 handover
execution.
Y CC event int 0-2147483647 - -
InterX2InFail_R
RC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_S1
AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_S1
AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_S1
AP_PATH_TO
count A call is released due to S1AP path
switch timeout (not received) during
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 113 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
the inter X2 handover execution.
InterX2InFail_S1
AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_X2
AP_CU_FAIL
count A call is released due to the X2AP
specification cause during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_X2
AP_LINK_FAIL
count A call is released due to the X2
SCTP link failure during the inter X2
handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_X2
AP_SIG_FAIL
count A call is released due to receiving
the X2AP signaling during the inter
X2 handover execution.
Y CC event int 0-2147483647 - -
InterX2InFail_X2
AP_SIG_TO
count A call is released due to X2AP
signaling timeout (not received)
during the inter X2 handover
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 114 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 21. Collection Time for X2 Handover In
For Inter X2 Handover In statistics, Attempt is counted when the target eNB receives the X2 Handover Request message, and Prepare
is counted after the target eNB transmits the X2 Handover Request Acknowledge message. The source eNB transmits the RRC Connec
tion Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the
UE. Success is counted when the handover is completed successfully and the X2 UE Context Release message is transmitted to the s
ource eNB. If the procedure from to fails, it is counted as Prepare Fail and returns the cause value and when the procedure fro
m to fails, it is counted as Inter X2 In Fail and returns the cause value.
UE MME S/GW
Rrc Connection
Reconfiguration
1 Attempt
2 Prepare
Handover Request
Target eNB
Measurement Report
Source eNB
HO Decision
Handover Request
Acknowledge
SN Status Transfer
Path Switch Request
Path Switch Request
Acknowledge Release Request
Call Release
3 Success
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 115 of 427
2600-00FET7GAT 6.0
5.4 S1 Handover Out
This section provides statistics data for S1 handovers between eNBs for each cell in reference with the source eNB.
Index
Name Range Description
cNum 0~2 Source Cell Index
tcId 0~268435455 Target Cell Index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterS1OutAtt count The number of attempts for S1
handover in SeNB
Y CC event int 0-2147483647 - -
InterS1OutPrepS
ucc
count The number of successes for S1
handover preparation in SeNB
Y CC event int 0-2147483647 - -
InterS1OutSucc count The number of successes for S1
handover execution in SeNB
Y CC event int 0-2147483647 - -
InterS1OutPrepF
ail_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB block
during inter S1 handover preparation.
Y CC event int 0~214748364
7
- -
InterS1OutPrepF count Preparation fails due to S1AP Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 116 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ail_S1AP_CU_F
AIL
specification cause during inter S1
handover preparation.
InterS1OutPrepF
ail_S1AP_LINK_
FAIL
count Preparation fails due to S1 SCTP link
failure during inter S1 handover
preparation.
Y CC event int 0-2147483647 - -
InterS1OutPrepF
ail_S1AP_RP_T
O
count Preparation fails due to S1AP
relocprep timeout (not received)
during the inter S1 handover
preparation.
Y CC event int 0-2147483647 - -
InterS1OutPrepF
ail_S1AP_SIG_F
AIL
count Preparation fails due to receiving
S1AP signaling during inter S1
handover preparation.
Y CC event int 0-2147483647 - -
InterS1OutFail_C
P_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_C
P_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB block
during the inter S1 handover
execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_U
P_GTP_FAIL
count A call is released due to the failure in
the GTP block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_U
P_MAC_FAIL
count A call is released due to the failure in
the MAC block during the inter S1
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 117 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover execution.
InterS1OutFail_U
P_PDCP_FAIL
count A call is released due to the failure in
the PDCP block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_U
P_RLC_FAIL
count A call is released due to the failure in
the RLC block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_R
RC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_S
1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_S
1AP_LINK_FAIL
count A call is released due to the S1 SCTP
link failure during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_S
1AP_RO_TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the inter S1 handover
execution.
Y CC event int 0-2147483647 - -
InterS1OutFail_S
1AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1OutCnt count S1 Handover Out collection count - CC event int 0~2147483647 - -
InterS1OutCid tcID tcID of which collection is requested - OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 118 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 22. Collection Time for S1 Handover Out
UE MME S/GW
Rrc Connection
Reconfiguration
Target eNB
Measurement Report
Source eNB
HO Decision
Handover Request
MME Status Transfer
Handover Notify
UE Context Release Command
Call Release
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
Handover Required
Handover Request
Acknowledge Handover Command
eNB Status Transfer
Tracking Area Update Procedure (NAS)
UE Context Release Complete
1 Attempt
2 Prepare
3 Success
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 119 of 427
2600-00FET7GAT 6.0
For Inter S1 Handover Out statistics, Attempt is counted when the S1 Handover Required message can be transmitted to the MME aft
er the inter S1 handover decision following the Measurement Report message arrival. Prepare is counted when the S1 Handover Comm
and message is received from the MME. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the t
arget eNB receives the RRC Connection Reconfiguration Complete message from the UE.
The MME transmits the S1 UE Context Release Command message to the source eNB when the handover is successfully completed in
the target eNB. At this point, the source eNB is counted as Success. When the procedure from to fails, it is counted as Prepar
e Fail and returns the cause value, and when the procedure from to fails, it is counted as Inter S1 Out Fail and returns the cau
se value.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 120 of 427
2600-00FET7GAT 6.0
5.5 S1 Handover In
This section provides statistics data for S1 handovers between eNBs for each cell in reference with the target eNB.
Index
Name Range Description
cNum 0~2 Target cell index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterS1InAtt count S1 handover attempt count in TeNB Y CC event int 0-2147483647 - -
InterS1InPrepSucc count S1 handover preparation success
count in TeNB
Y CC event int 0-2147483647 - -
InterS1InSucc count S1 handover execution success
count in TeNB
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
CP_CC_TO
count Preparation fails due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the inter
S1 handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 121 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
block during inter S1 handover
preparation.
InterS1InPrepFail_
UP_GTP_FAIL
count Preparation fails due to internal
failure in the GTP block during the
inter S1 handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
UP_MAC_FAIL
count Preparation fails due to internal
failure in the MAC block during the
inter S1 handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
UP_PDCP_FAIL
count Preparation fails due to internal
failure in the PDCP block during the
inter S1 handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
UP_RLC_FAIL
count Preparation fails due to internal
failure in the RLC block during the
inter S1 handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
CP_BH_CAC_FAIL
count Preparation fails due to insufficient
backhaul-based eNB resources
during inter S1 handover
preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
CP_CAPA_CAC_F
AIL
count Preparation fails due to insufficient
capacity-based eNB resources
during inter S1 handover
preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
CP_QOS_CAC_F
AIL
count Preparation fails due to insufficient
QoS-based eNB resources during
inter S1 handover preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 122 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterS1InPrepFail_
S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during inter S1
handover preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
S1AP_LINK_FAIL
count Preparation fails due to S1 SCTP
link failure during inter S1 handover
preparation.
Y CC event int 0-2147483647 - -
InterS1InPrepFail_
S1AP_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during inter S1
handover preparation.
Y CC event int 0-2147483647 - -
InterS1InFail_CP_
CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the inter
S1 handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_CP_
CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by ECCB
block during the inter S1 handover
execution.
Y CC event int 0-2147483647 - -
InterS1InFail_UP_
GTP_FAIL
count A call is released due to the failure
in the GTP block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_UP_
MAC_FAIL
count A call is released due to the failure
in the MAC block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_UP_
PDCP_FAIL
count A call is released due to the failure
in the PDCP block during the inter
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 123 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1 handover execution.
InterS1InFail_UP_
RLC_FAIL
count A call is released due to the failure
in the RLC block during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_RRC
_HC_TO
count A call is released due to HO
command timeout (not received)
during the inter S1 handover
execution.
Y CC event int 0-2147483647 - -
InterS1InFail_RRC
_SIG_FAIL
count A call is released due to receiving
RRC signaling during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_S1A
P_CU_FAIL
count A call is released due to the S1AP
specification cause during the inter
S1 handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_S1A
P_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_S1A
P_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the inter S1
handover execution.
Y CC event int 0-2147483647 - -
InterS1InFail_S1A
P_SIG_TO
count A call is released due to S1AP
signaling timeout (not received)
during the inter S1 handover
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 124 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 23. Collection Time for S1 Handover In
For inter S1 handover in statistics, when the target eNB receives the S1 Handover Request message, it is counted as Attempt; when th
e target eNB transmits the S1 Handover Request Acknowledge message, it is counted as Prepare. The source eNB transmits the RRC
Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message fr
om the UE. Success is counted after the handover is successfully completed and the S1 Handover Notify message is transmitted to the
MME. When the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from
to fails, it is counted as Inter S1 In Fail, returning the cause value.
Handover Request
Handover Request
Acknowledge
UE MME S/GW
Rrc Connection
Reconfiguration
Attempt
Prepare
Target eNB
Measurement Report
Source eNB
HO Decision
MME Status Transfer
Handover Notify
UE Context Release Command
Call Release
Success
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
Handover Required
Handover Command
eNB Status Transfer
Tracking Area Update Procedure (NAS)
UE Context Release Complete
3
1
2
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 125 of 427
2600-00FET7GAT 6.0
5.6 Handover Time (Average, Max)
This section provides statistics data for the average setup time and the maximum setup time of the handover interrupt time in the TeN
B for each cell.
Index
Name Range Description
cNum 0~2 Cell index
scID 0~268435455 Source cell index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IntraHOTime ms Time taken from transmitting
the
RRCConnectionReconfiguratio
n message to the UE until after
receiving the RRCConnection
ReconfigurationComplete
message from the UE.
Y GAUGE event float 0-60*Period*1000 IntraHOTimeT
ot/IntraHOTim
eCnt
sum
(IntraHOTimeTot)/
sum
(IntraHOTimeCnt)
IntraHOTimeM
ax
ms Average maximum intra HO
interrupt time
Y GAUGE event float 0-60*Period*1000 - max
(IntraHOTimeMax)
IntraHOTimeT
ot
ms Sum of Intra HO Interrupt time Y GAUGE event float 0-3.4*10^38 - -
IntraHOTimeC
nt
count Count of IntraHOTime
collected
Y GAUGE event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 126 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1HOTime ms Average S1 HO interrupt time Y GAUGE event float 0-60*Period*1000 S1HOTimeTot/
S1HOTimeCnt
sum (S1HOTimeTot)/
sum (S1HOTimeCnt)
S1HOTimeMax ms Average maximum S1 HO
interrupt time
Y GAUGE event float 0-60*Period*1000 - max (S1HOTimeMax)
S1HOTimeTot ms Sum of S1 HO interrupt time Y GAUGE event float 0-3.4*10^38 - -
S1HOTimeCnt count Count of S1HOTime collected Y GAUGE event int 0-2147483647 - -
X2HOTime ms Average X2 HO interrupt time Y GAUGE event float 0-60*Period*1000 X2HOTimeTot/
X2HOTimeCnt
sum (X2HOTimeTot)/
sum (X2HOTimeCnt)
X2HOTimeMax ms Average maximum X2 HO
interrupt time
Y GAUGE event float 0-60*Period*1000 - max (X2HOTimeMax)
X2HOTimeTot ms Sum of X2 HO Interrupt time Y GAUGE event float 0-3.4*10^38 - -
X2HOTimeCnt count Count of X2HOTime collected Y GAUGE event int 0-2147483647 -
HoTimeCnt count The sum of X2 HO Interrupt
time
- CC event int 0~2147483647 - -
HoTimeCid scID Collected X2HOTime count - OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 127 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 24. Collection Time for Handover Time (INTRA)
eNB UE
UE moves to Intra eNB Cell
Rrc Connection Reconfiguration
Rrc Connection Reconfiguration Complete
Measurement Report
HO Decision
Target Cell Preparation
Internal Path Switch
HO Time
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 128 of 427
2600-00FET7GAT 6.0
Figure 25. Collection Time for Handover Time (INTER S1)
UE MME S/GW
Rrc Connection
Reconfiguration
Handover Request
Target eNB
Measurement Report
Source eNB
HO Decision
Handover Request
Acknowledge
Handover Required
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
Handover Command
HO Time
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 129 of 427
2600-00FET7GAT 6.0
Figure 26. Collection Time for Handover Time (INTER X2)
Handover time statistics are based on the Target eNB. Intra handover time refers to the time taken from transmitting the RRC Connect
ion Reconfiguration message to the UE until after receiving the RRC Connection Reconfiguration Complete message. Inter X2 handover
time refers to the time taken from after transmitting the X2 Handover Request Acknowledge message at the target eNB until receivin
g the RRC Connection Reconfiguration Complete message from the UE. Inter X2 handover time refers to the time taken from after tra
nsmitting the S1 Handover Request Acknowledge message at the Target eNB until receiving the RRC Connection Reconfiguration Com
plete message from the UE.
UE MME S/GW
Rrc Connection
Reconfiguration
Handover Request
Target eNB
Measurement Report
Source eNB
HO Decision
Handover Request
Acknowledge
UE moves to Inter eNB Cell
Rrc Connection Reconfiguration Complete
HO Time
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 130 of 427
2600-00FET7GAT 6.0
5.7 Outgoing Intra-Frequency Handover
If the frequency is the same between the source and target cells, handover statistics are collected.
Index
Name Range Description
cNum 0~2 Target Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IntraFreqOutAtt count Outgoing intra-frequency handover
attempt count
Y CC event int 0-2147483647 - -
IntraFreqOutPrepS
ucc
count Outgoing intra-frequency handover
preparation success count
Y CC event int 0-2147483647 - -
IntraFreqOutSucc count Outgoing intra-frequency handover
execution success count
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECCB or by the
ECCB block during the outgoing
intra-frequency handover
preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during the
outgoing intra-frequency handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 131 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
preparation.
IntraFreqOutPrepF
ail_S1AP_LINK_F
AIL
count Preparation fails due to S1 SCTP
link failure during the outgoing
intra-frequency handover
preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_S1AP_RP_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the outgoing intra-frequency
handover preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepFai
l_S1AP_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the
outgoing intra-frequency handover
preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_X2AP_CU_FAIL
count Preparation fails due to X2AP
specification cause during the
outgoing intra-frequency handover
preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_X2AP_LINK_F
AIL
count Preparation fails due to X2 SCTP
link failure during the outgoing
intra-frequency handover
preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepF
ail_X2AP_RP_TO
count Preparation fails due to X2AP
relocprep timeout (not received)
during the outgoing intra-frequency
handover preparation.
Y CC event int 0-2147483647 - -
IntraFreqOutPrepFai count Preparation fails due to receiving Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 132 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
l_X2AP_SIG_FAIL X2AP signaling during the
outgoing intra-frequency handover
preparation.
IntraFreqOutFail_
CP_CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
during the outgoing intra-frequency
handover execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_
CP_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the outgoing
intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_
UP_GTP_FAIL
count A call is released due to the failure
in the GTP block during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_
UP_MAC_FAIL
count A call is released due to the failure
in the MAC block during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_
UP_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 133 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IntraFreqOutFail_
UP_RLC_FAIL
count A call is released due to the failure
in the RLC block during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the outgoing
intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_S
1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_S
1AP_LINK_FAIL
count A call is released due to S1 SCTP
link failure during the outgoing
intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_S
1AP_RO_TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the outgoing intra-
frequency handover execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_S
1AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_X
2AP_CU_FAIL
count A call is released due to the X2AP
specification cause during the
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 134 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
outgoing intra-frequency handover
execution.
IntraFreqOutFail_X
2AP_LINK_FAIL
count A call is released due to X2 SCTP
link failure during the outgoing
intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_X
2AP_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not
received) during the outgoing
intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
IntraFreqOutFail_X
2AP_SIG_FAIL
count A call is released due to receiving
the X2AP signaling during the
outgoing intra-frequency handover
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 135 of 427
2600-00FET7GAT 6.0
5.8 Outgoing Inter-frequency Handover with Measurement Gap
The handover statistics is collected if the frequency information between source and target is different and measurement gap is used.
Index
Name Range Description
cNum 0~2 Target Cell Index
TargetEarfcnDl 0~268435455 Target neighbor cell frequency (EARFCN DL)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterFreqMeasGap
OutAtt
count Outgoing inter-frequency handover
(measurement gap assisted)
attempt count
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepSucc
count Outgoing inter-frequency handover
(measurement gap assisted)
preparation success count
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutSucc
count Outgoing inter-frequency handover
(measurement gap assisted)
execution success count
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_CP_C
C_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECCB or by the ECCB
block during the outgoing inter-
frequency handover (measurement
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 136 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
gap assisted) preparation.
InterFreqMeasGap
OutPrepFail_S1AP
_CU_FAIL
count Preparation fails due to the S1AP
specification cause during the
outgoing inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_S1AP
_LINK_FAIL
count Preparation fails due to the S1
SCTP link failure during the
outgoing inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_S1AP
_RP_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the outgoing inter-frequency
handover (measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_S1AP
_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the outgoing
inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_X2AP
_CU_FAIL
count Preparation fails due to the X2AP
specification cause during the
outgoing inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 137 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterFreqMeasGap
OutPrepFail_X2AP
_LINK_FAIL
count Preparation fails due to the X2
SCTP link failure during the
outgoing inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_X2AP
_RP_TO
count Preparation fails due to X2AP
relocprep timeout (not received)
during the outgoing inter-frequency
handover (measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutPrepFail_X2AP
_SIG_FAIL
count Preparation fails due to receiving
X2AP signaling during the outgoing
inter-frequency handover
(measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqMeasGapO
utFail_CP_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_CP_CC_F
AIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
block during the outgoing inter-
frequency handover (measurement
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 138 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
gap assisted) execution.
InterFreqMeasGap
OutFail_UP_GTP_
FAIL
count A call is released due to the failure
in the GTP block during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_UP_MAC_
FAIL
count A call is released due to the failure
in the MAC block during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_UP_PDCP
_FAIL
count A call is released due to the failure
in the PDCP block during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_UP_RLC_
FAIL
count A call is released due to the failure
in the RLC block during the outgoing
inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_RRC_SIG
_FAIL
count A call is released due to receiving
RRC signaling during the outgoing
inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 139 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterFreqMeasGap
OutFail_S1AP_CU
_FAIL
count A call is released due to the S1AP
specification cause during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_S1AP_LIN
K_FAIL
count A call is released due to the S1
SCTP link failure during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_S1AP_RO
_TO
count A call is released due to the S1AP
relocoverall timeout (not received)
during the outgoing inter-frequency
handover (measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_S1AP_SIG
_FAIL
count A call is released due to receiving
S1AP signaling during the outgoing
inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_X2AP_CU
_FAIL
count A call is released due to the X2AP
specification cause during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap count A call is released due to the X2 Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 140 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
OutFail_X2AP_LIN
K_FAIL
SCTP link failure during the
outgoing inter-frequency handover
(measurement gap assisted)
execution.
InterFreqMeasGap
OutFail_X2AP_RO
_TO
count A call is released due to the X2AP
relocoverall timeout (not received)
during the outgoing inter-frequency
handover (measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqMeasGap
OutFail_X2AP_SIG
_FAIL
count A call is released due to receiving
X2AP signaling during the outgoing
inter-frequency handover
(measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqOutWithG
apCnt
count Outgoing Inter-Frequency Handover
(measurement gap assisted)
collection count
- CC event int 0~2147483647 - -
InterFreqOutWithG
apTargetEarfcnDl
Target
Earfc
nDl
TargetEarfcnDl of which collection is
requested
- OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 141 of 427
2600-00FET7GAT 6.0
5.9 Outgoing Inter-frequency Handover without Measurement Gap
The handover statistics are collected if the frequency is different between the source and target cells, and measurement gap is not used.
Index
Name Range Description
cNum 0~2 Target Cell Index
TargetEarfcnDl 0~268435455 Target neighbor cell frequency (EARFCN DL)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterFreqNoMeasGa
pOutAtt
count Outgoing inter-frequency
handover (no measurement gap
assisted) attempt count
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepSucc
count Outgoing inter-frequency
handover (no measurement gap
assisted) preparation success
count
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutSucc
count Outgoing inter-frequency
handover (no measurement gap
assisted) execution success
count
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_CP_C
C_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECCB or by the
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 142 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ECCB block during the outgoing
inter-frequency handover (no
measurement gap assisted)
preparation.
InterFreqNoMeasGa
pOutPrepFail_S1AP
_CU_FAIL
count Preparation fails due to the
S1AP specification cause during
the outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_S1AP
_LINK_FAIL
count Preparation fails due to the S1
SCTP link failure during the
outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_S1AP
_RP_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the outgoing inter-
frequency handover (no
measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_S1AP
_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the
outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa count Preparation fails due to the Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 143 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
pOutPrepFail_X2AP
_CU_FAIL
X2AP specification cause during
the outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
InterFreqNoMeasGa
pOutPrepFail_X2AP
_LINK_FAIL
count Preparation fails due to the X2
SCTP link failure during the
outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_X2AP
_RP_TO
count Preparation fails due to X2AP
relocprep timeout (not received)
during the outgoing inter-
frequency handover (no
measurement gap assisted)
preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutPrepFail_X2AP
_SIG_FAIL
count Preparation fails due to receiving
X2AP signaling during the
outgoing inter-frequency
handover (no measurement gap
assisted) preparation.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGap
OutFail_CP_CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
during the outgoing inter-
frequency handover (no
measurement gap assisted)
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 144 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
execution.
InterFreqNoMeasGa
pOutFail_CP_CC_F
AIL
count A call is released due to reset
notification (eNB failure or bloc
restart) from ECMB or by the
ECCB block during the outgoing
inter-frequency handover (no
measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_UP_GTP_
FAIL
count A call is released due to the
failure in the GTP block during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_UP_MAC_
FAIL
count A call is released due to the
failure in the MAC block during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_UP_PDCP
_FAIL
count A call is released due to the
failure in the PDCP block during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_UP_RLC_
FAIL
count A call is released due to the
failure in the RLC block during
the outgoing inter-frequency
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 145 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover (no measurement gap
assisted) execution.
InterFreqNoMeasGa
pOutFail_RRC_SIG
_FAIL
count A call is released due to
receiving RRC signaling during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_S1AP_CU
_FAIL
count A call is released due to the
S1AP specification cause during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_S1AP_LIN
K_FAIL
count A call is released due to the S1
SCTP link failure during the
outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_S1AP_RO
_TO
count A call is released due to the
S1AP relocoverall timeout (not
received) during the outgoing
inter-frequency handover (no
measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_S1AP_SIG
_FAIL
count A call is released due to
receiving S1AP signaling during
the outgoing inter-frequency
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 146 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover (no measurement gap
assisted) execution.
InterFreqNoMeasGa
pOutFail_X2AP_CU
_FAIL
count A call is released due to the
X2AP specification cause during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_X2AP_LIN
K_FAIL
count A call is released due to the X2
SCTP link failure during the
outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_X2AP_RO
_TO
count A call is released due to the
X2AP relocoverall timeout (not
received) during the outgoing
inter-frequency handover (no
measurement gap assisted)
execution.
Y CC event int 0-2147483647 - -
InterFreqNoMeasGa
pOutFail_X2AP_SIG
_FAIL
count A call is released due to
receiving X2AP signaling during
the outgoing inter-frequency
handover (no measurement gap
assisted) execution.
Y CC event int 0-2147483647 - -
InterFreqOutWithOu
tGapCnt
count Outgoing Inter-Frequency
Handover (No measurement gap
assisted) collection count
CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 147 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
InterFreqOutWithOu
tGapTargetEarfcnDl
Target
Earfcn
Dl
TargetEarfcnDl of which
collection is requested
OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 148 of 427
2600-00FET7GAT 6.0
5.10 Outgoing Handover with DRX
The handover statistics are collected when DRX is set for the UE.
Index
Name Range Description
cNum 0~2 Target Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DrxOutAtt count Outgoing handover (with DRX) attempt
count
Y CC event int 0-2147483647 - -
DrxOutPrepSucc count Outgoing handover (with DRX)
preparation success count
Y CC event int 0-2147483647 - -
DrxOutSucc count Outgoing handover (with DRX)
execution success count
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
CP_CC_FAIL
count Preparation fails due to reset notification
(eNB failure or block restart) from ECCB
or by the ECCB block during the outgoing
handover (with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during the outgoing
handover (with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
S1AP_LINK_FAI
count Preparation fails due to the S1 SCTP
link failure during the outgoing handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 149 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
L (with DRX) preparation.
DrxOutPrepFail_
S1AP_RP_TO
count Preparation fails due to S1AP relocprep
timeout (not received) during the
outgoing handover (with DRX)
preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
S1AP_SIG_FAIL
count Preparation fails due to receiving S1AP
signaling during the outgoing handover
(with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
X2AP_CU_FAIL
count Preparation fails due to X2AP
specification cause during the outgoing
handover (with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
X2AP_LINK_FAI
L
count Preparation fails due to the X2 SCTP
link failure during the outgoing handover
(with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
X2AP_RP_TO
count Preparation fails due to X2AP relocprep
timeout (not received) during the
outgoing handover (with DRX)
preparation.
Y CC event int 0-2147483647 - -
DrxOutPrepFail_
X2AP_SIG_FAIL
count Preparation fails due to receiving X2AP
signaling during the outgoing handover
(with DRX) preparation.
Y CC event int 0-2147483647 - -
DrxOutFail_CP_
CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 150 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DrxOutFail_CP_
CC_FAIL
count A call is released due to reset
notification (eNB failure or block restart)
from ECMB or by the ECCB block
during the outgoing handover (with
DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_UP_
GTP_FAIL
count A call is released due to the failure in
the GTP block during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_UP_
MAC_FAIL
count A call is released due to the failure in
the MAC block during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_UP_
PDCP_FAIL
count A call is released due to the failure in
the PDCP block during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_UP_
RLC_
FAIL
count A call is released due to the failure in
the RLC block during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_RRC
_SIG_FAIL
count A call is released due to receiving RRC
signaling during the outgoing handover
(with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_S1A
P_CU_FAIL
count A call is released due to the S1AP
specification cause during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_S1A
P_LINK_FAIL
count A call is released due to the S1 SCTP
link failure during the outgoing handover
(with DRX) execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 151 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DrxOutFail_S1A
P_RO_TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the outgoing handover (with
DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_S1A
P_SIG_FAIL
count A call is released due to receiving S1AP
signaling during the outgoing handover
(with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_X2A
P_CU_FAIL
count A call is released due to the X2AP
specification cause during the outgoing
handover (with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_X2A
P_LINK_FAIL
count A call is released due to the X2 SCTP
link failure during the outgoing handover
(with DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_X2A
P_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not received)
during the outgoing handover (with
DRX) execution.
Y CC event int 0-2147483647 - -
DrxOutFail_X2A
P_SIG_FAIL
count A call is released due to receiving X2AP
signaling during the outgoing handover
(with DRX) execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 152 of 427
2600-00FET7GAT 6.0
5.11 Outgoing Handover without DRX
The handover statistics is collected when DRX is not set on the UE.
Index
Name Range Description
cNum 0~2 Target Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
NoDrxOutAtt count Outgoing handover (without DRX)
attempt count
Y CC event int 0-2147483647 - -
NoDrxOutPrepSu
cc
count Outgoing handover (without DRX)
preparation success count
Y CC event int 0-2147483647 - -
NoDrxOutSucc count Outgoing handover (without DRX)
execution success count
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa
il_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the outgoing
handover (without DRX)
preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFail
_S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during the
outgoing handover (without DRX)
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 153 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
preparation.
NoDrxOutPrepFa
il_S1AP_LINK_F
AIL
count Preparation fails due to the S1
SCTP link failure during the
outgoing handover (without DRX)
preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa
il_S1AP_RP_TO
count Preparation ails due to S1AP
relocprep timeout (not received)
during the outgoing handover
(without DRX) preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa
il_S1AP_SIG_FA
IL
count Preparation fails due to receiving
S1AP signaling during the outgoing
handover (without DRX)
preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFail
_X2AP_CU_FAIL
count Preparation fails due to X2AP
specification cause during the
outgoing handover (without DRX)
preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa
il_X2AP_LINK_F
AIL
count Preparation fails due to the X2
SCTP link failure during the
outgoing handover (without DRX)
preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa
il_X2AP_RP_TO
count Preparation fails due to X2AP
relocprep timeout (not received)
during the outgoing handover
(without DRX) preparation.
Y CC event int 0-2147483647 - -
NoDrxOutPrepFa count Preparation fails due to receiving Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 154 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
il_X2AP_SIG_FA
IL
X2AP signaling during the outgoing
handover (without DRX)
preparation.
NoDrxOutFail_C
P_CC_TO
count A call is released due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during
the outgoing handover (without
DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_C
P_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the outgoing
handover (without DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_U
P_GTP_FAIL
count A call is released due to the failure
in the GTP block during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_U
P_MAC_FAIL
count A call is released due to the failure
in the MAC block during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_U
P_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_U count A call is released due to the failure Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 155 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
P_RLC_FAIL in the RLC block during the
outgoing handover (without DRX)
execution.
NoDrxOutFail_R
RC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the outgoing
handover (without DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_S1
AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_S1
AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_S1
AP_RO_TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the outgoing handover
(without DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_S1
AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the outgoing
handover (without DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_X2
AP_CU_FAIL
count A call is released due to the X2AP
specification cause during the
outgoing handover (without DRX)
execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_X2 count A call is released due to the X2 Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 156 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
AP_LINK_FAIL SCTP link failure during the
outgoing handover (without DRX)
execution.
NoDrxOutFail_X2
AP_RO_TO
count A call is released due to X2AP
RelocOverall timeout (not received)
during the outgoing handover
(without DRX) execution.
Y CC event int 0-2147483647 - -
NoDrxOutFail_X2
AP_SIG_FAIL
count A call is released due to receiving
X2AP signaling during the outgoing
handover (without DRX) execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 157 of 427
2600-00FET7GAT 6.0
6 HO UTRAN
Inter-RAT UTRAN PS Handover: Inter-RAT UTRAN PS Handover Out, Inter-
RAT UTRAN PS Handover In
This section provides statistics data for handover between the LTE system and UTR
AN system for each cell. The following shows the message flow for the PS hando
ver procedure from the E-UTRAN to the UTRAN.
Figure 27. PS Handover Procedure from E-UTRAN to UTRAN
UE Source eNB Target RNS Source MME Source S-GW Target SGSN Target S-GW P-GW
Downlink/Uplink data Downlink/Uplink data
1) Handover Initiation
2) HANDOVER REQUIRED
3) FORWARD RELOCATION REQUEST
4) Create Session
Request/Response 5) RELOCATION REQUEST
6) RELOCATION REQUEST ACKNOWLEDGE
7) Create Indirect Data
Forwarding Tunnel Request/Response
8) FORWARD RELOCATION RESPONSE
9) Create Indirect Data
10) HANDOVER COMMAND
UTRAN Command
11) Mobility from E- Indirect data forwarding
Indirect data forwarding
12) HO to UTRAN Complete 13) RELOCATION COMPLETE
14) FORWARD RELOCATION COMPLETE
NOTIFICATION
15) FORWARD RELOCATION COMPLETE
ACKNOWLEDGE
17) Modify Bearer
Request/Response
18) MODIFY BEARER
RESPONSE Downlink/Uplink data Downlink/Uplink data Downlink/Uplink data
19) Routing Area Update procedure
20) S1 Release
Request/Response
21) Delete Session
22) Create Indirect Data
Forwarding Tunnel Request/Response
23) Create Indirect Data
Forwarding Tunnel Request/Response
Downlink/Uplink data
Forwarding Tunnel Request/Response
16) MODIFY BEARER
REQUEST
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 158 of 427
2600-00FET7GAT 6.0
Step Description
1) The source eNB determines the PS handover to the UTRAN. This decision is made
according to the measurement report received from the UE.
2) The source eNB transmits the HANDOVER REQUIRED message to the MME.
The source eNB then includes the source RNC to target RNC transparent container IE
information in the message for relaying the necessary information to the target RNC.
3)-4) The source MME recognizes the handover from the target ID IE of the HANDOVER
REQUIRED message to the UTRAN and transmits the FORWARD RELOCATION
REQUEST message to the target SGSN. The target SGSN determines whether to
change the S-GW. If change is required, it carries out the Create Session
Request/Response procedure with a new S-GW.
5)-6) The target SGSN transmits the RELOCATION REQUEST message to the target RNC
to request resource allocation for the target RNC. The target RNC performs CAC and
resource allocation for each RAB for which handover is requested, and transmits to the
target SGSN the RELOCATION REQUEST ACKNOWLEDGE message that
encapsulates the result. The RELOCATION REQUEST ACKNOWLEDGE message
encapsulates the Target RNC to Source RNC Transparent Container IE to be
transmitted to the source eNB.
7)-9) To perform the forwarding tunnel setup, the target SGSN performs the Create Indirect
Data Forwarding Tunnel Request/Response procedure with target S-GW and transmits
the FORWARD RELOCATION RESPONSE message to the source MME. To perform
the forwarding tunnel setup, the source MME carries out the Create Indirect Data
Forwarding Tunnel Request/Response procedure with the source S-GW.
10)-11) The source MME transmits the HANDOVER COMMAND message to the source eNB to
complete the handover preparation procedure to the target UTRAN. The source eNB
configures the MOBILITY FROM E-UTRAN COMMAND containing the Target RNC to
Source RNC Transparent Container IE in the HANDOVER COMMAND message and
transmits it to the UE to request the PS handover to the UTRAN.
12) The UE performs synchronization with the target UTRAN and connects to the target cell
via the RACH.
After UE is successfully connected to the target cell, UE transmits the HANDOVER TO
UTRAN COMPLETE message to the target UTRAN to complete the handover
procedure.
13)-15) The target RNC transmits the RELOCATION COMPLETE message to the target SGSN
to notify that the handover procedure from the UE to the UTRAN has been completed
successfully.
The target SGSN transmits the FORWARD RELOCATION COMPLETE NOTIFICATION
message to the source MME. At this time, the source MME operates the waiting timer
for releasing the resource of the E-UTRAN and transmits the FORWARD RELOCATION
COMPLETE ACKNOWLEDGE response message to the target SGSN. The target
SGSN operates the waiting timer for releasing the forwarding tunnel at the time when
the source MME receives the response message.
16)-18) The target SGSN transmits the Modify Bearer Request message for each PDN
connection to the target S-GW. Subsequent downlink packets are then transmitted from
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 159 of 427
2600-00FET7GAT 6.0
Step Description
the S-GW to the target RNC. The target S-GW performs the Modify Bearer
Request/Response procedure with the P-GW and transmits the Modify Bearer
Response message to the target SGSN.
19) When UE satisfies the conditions specified in section 5.5.2.1 of TS 23.401, the Routing
Area Update procedure starts.
20)-23) When the timer at Step 14) expires, the source MME requests the source eNB and the
source S-GW to release the resources. When the timer at Step 15) expires, the target
SGSN releases the resources release allocated for forwarding tunnel with the target S-
GW.
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 160 of 427
2600-00FET7GAT 6.0
6.1 Inter-RAT UTRAN PS Handover OUT
This section provides statistics data for outgoing handover between the LTE and UTRAN systems for each cell. The collection time for
HO attempt, HO preparation and HO success statistics is the same as that for S1 handover out statistics.
Index
Name Range Description
cNum 0~2 Source Cell Index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RatOutAttUTRAN count LTE to inter-RAT UTRAN handover
attempt count.
Y CC event int 0-2147483647 - -
RatOutPrepSuccUT
RAN
count LTE to inter-RAT UTRAN handover
preparation success count
Y CC event int 0-2147483647 - -
RatOutSuccUTRAN count LTE to inter-RAT UTRAN handover
execution success count
Y CC event int 0-2147483647 - -
RatOutPrepFailUTR
AN_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 161 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RatOutPrepFailUTR
AN_S1AP_CU_FAI
L
count Preparation fails due to S1AP
specification cause during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatOutPrepFailUTR
AN_S1AP_LINK_F
AIL
count Preparation fails due to S1 SCTP
link failure during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
RatOutPrepFailUTR
AN_S1AP_RP_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the UTRAN handover
preparation.
Y CC event int 0-2147483647 - -
RatOutPrepFailUTR
AN_S1AP_SIG_FAI
L
count Preparation fails due to receiving
S1AP signaling during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
CP_CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
during the UTRAN handover
execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
CP_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
UP_GTP_FAIL
count A call is released due to the failure
in the GTP block during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 162 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RatOutFailUTRAN_
UP_MAC_FAIL
count A call is released due to the failure
in the MAC block during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
UP_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
UP_RLC_FAIL
count A call is released due to the failure
in the RLC block during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
S1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
S1AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
S1AP_RO_TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the UTRAN handover
execution.
Y CC event int 0-2147483647 - -
RatOutFailUTRAN_
S1AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 163 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 28. Collection Time for Inter-RAT UTRAN PS Handover Out
For inter-RAT UTRAN Handover Out statistics, Attempt is counted when the S1 Handover Required message is transmitted after the U
TRAN handover decision following the Measurement Report message arrival, and Prepare is counted when the Mobility Eutra Comman
d message is transmitted to the UE. Success is counted when the handover is completed and the MME transmits the UE Context Rele
ase Complete message.
If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai
ls, it is counted as Inter RAT UTRAN HO Out Fail, returning the cause value.
UE MME
Attempt
Prepare
Measurement Report
Source eNB
HO Decision
UE Context Release Command
Call Release Success
Handover Required
UE Context Release Complete
1
2
3
Handover Command
Mobility From EUTRA Command
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 164 of 427
2600-00FET7GAT 6.0
6.2 Inter-RAT UTRAN PS Handover IN
This section provides statistics data for handover between the LTE system and UTRAN system for each cell.
Index
Name Range Description
cNum 0~2 Source Cell Index
HOCause 0~1 Handover cause
0: Handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RatInAttUTRAN count Inter-RAT UTRAN to LTE handover
attempt count
Y CC event int 0-2147483647 - -
RatInPrepSuccUT
RAN
count Inter-RAT UTRAN to LTE handover
preparation success count.
Y CC event int 0-2147483647 - -
RatInSuccUTRAN count Inter-RAT UTRAN to LTE handover
execution success count.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_CP_CC_TO
count Preparation fails due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 165 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
restart) from ECMB or by the ECCB
block during the UTRAN handover
preparation.
RatInPrepFailUTRA
N_UP_GTP_FAIL
count Preparation fails due to internal
failure in the GTP block during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTRA
N_UP_MAC_FAIL
count Preparation fails due to internal
failure in the MAC block during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_UP_PDCP_FA
IL
count Preparation fails due to internal
failure in the PDCP block during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTRA
N_UP_RLC_FAIL
count Preparation fails due to internal
failure in the RLC block during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_CP_BH_CAC
_FAIL
count Preparation fails due to insufficient
backhaul-based eNB resources
during the UTRAN handover
preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_CP_CAPA_CA
C_FAIL
count Preparation fails due to insufficient
capacity-based eNB resources
during the UTRAN handover
preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_CP_QOS_CA
C_FAIL
count Preparation fails due to insufficient
QoS-based eNB resources during
the UTRAN handover preparation.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 166 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RatInPrepFailUTR
AN_S1AP_CU_FA
IL
count Preparation fails due to S1AP
specification cause during the
UTRAN handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_S1AP_LINK_F
AIL
count Preparation fails due to S1 SCTP
link failure during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
RatInPrepFailUTR
AN_S1AP_SIG_F
AIL
count Preparation fails due to receiving
S1AP signaling during the UTRAN
handover preparation.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
CP_CC_TO
count A call is released due to call control
timeout in the protocol blocks (MAC,
RLC, PDCP, GTP) during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
CP_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
block during the UTRAN handover
preparation.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
UP_GTP_FAIL
count A call is released due to the failure
in the GTP block during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
UP_MAC_FAIL
count A call is released due to the failure
in the MAC block during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
UP_PDCP_FAIL
count A call is released due to the failure
in the PDCP block during the
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 167 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UTRAN handover execution.
RatInFailUTRAN_
UP_RLC_FAIL
count A call is released due to the failure
in the RLC block during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
RRC_HC_TO
count A call is released due to HO
command timeout (not received)
during the UTRAN handover
execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
RRC_SIG_FAIL
count A call is released due to receiving
RRC signaling during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
S1AP_CU_FAIL
count A call is released due to the S1AP
specification cause during the
UTRAN handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
S1AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
S1AP_SIG_FAIL
count A call is released due to receiving
S1AP signaling during the UTRAN
handover execution.
Y CC event int 0-2147483647 - -
RatInFailUTRAN_
S1AP_SIG_TO
count A call is released due to S1AP
signaling timeout (not received)
during the UTRAN handover
execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 168 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 29. Collection Time for Inter-RAT UTRAN PS Handover In
For Inter-RAT UTRAN In statistics, Attempt is counted when the target eNB receives the S1 Handover Request message, and Prepare
is counted after the target eNB transmits the S1 Handover Request Acknowledge message. The target eNB receives the RRC Connectio
n Reconfiguration Complete message from the UE. Success is counted after the handover is successfully completed and the S1 Handov
er Notify message is transmitted to the MME. If the procedure from to fails, it is counted as Prepare Fail, returning the cause v
alue, and when the procedure from to fails, it is counted as Inter RAT UTRAN In Fail, returning the cause value.
UE MME Target eNB
Handover Request
Handover Notify
Attempt 1
Prepare 2
Success 3
Handover Request Acknowledge
RRC Connection Reconfiguration Complete
(Handover to E-UTRAN Complete)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 169 of 427
2600-00FET7GAT 6.0
6.3 UTRAN SRVCC
This section provides statistics data for SRVCC handover to UTRAN.
Index
Name Range Description
cNum 0~2 Source Cell Index
HOCause 0~1 Handover Cause
0: handover desirable for radio reasons
1: reserved
HOIndication 0~1 -
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UtranSrvccOutAtt count UTRAN SRVCC Handover
attempt count
Y CC event int 0~2147483647 - -
UtranSrvccOutPrepSu
cc
count UTRAN SRVCC Handover
preparation success count
Y CC event int 0~2147483647 - -
UtranSrvccOutSucc count UTRAN SRVCC Handover
execution success count
Y CC event int 0~2147483647 - -
UtranSrvccOutPrepFai
l_CP_CC_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the UTRAN
SRVCC preparation.
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 170 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UtranSrvccOutPrepFai
l_S1AP_CU_FAIL
count Preparation fails due to S1AP
specification cause during the
UTRAN SRVCC preparation
Y CC event int 0~2147483647 - -
UtranSrvccOutPrepFai
l_S1AP_LINK_FAIL
count Preparation fails due to S1
SCTP link failure during the
UTRAN SRVCC preparation.
Y CC event int 0~2147483647 - -
UtranSrvccOutPrepFai
l_S1AP_RP_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the UTRAN SRVCC
preparation.
Y CC event int 0~2147483647 - -
UtranSrvccOutPrepFai
l_S1AP_SIG_FAIL
count Preparation fails due to receiving
S1AP signaling during the
UTRAN SRVCC preparation
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_CP
_CC_TO
count A call is released due to call
control timeout in the protocol
blocks (MAC, RLC, PDCP, GTP)
during the UTRAN SRVCC
execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_CP
_CC_FAIL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the UTRAN
SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_UP
_GTP_FAIL
count A call is released due to the
failure in the GTP block during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 171 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UtranSrvccOutFail_UP
_MAC_FAIL
count A call is released due to the
failure in the MAC block during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_UP
_PDCP_FAIL
count A call is released due to the
failure in the PDCP block during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_UP
_RLC_FAIL
count A call is released due to the
failure in the RLC block during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_R
RC_SIG_FAIL
count A call is released due to
receiving RRC signaling during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_S1
AP_CU_FAIL
count A call is released due to the
S1AP specification cause during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_S1
AP_LINK_FAIL
count A call is released due to the S1
SCTP link failure during the
UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_S1
AP_RO_TO
count A call is released due to S1AP
relocoverall timeout (not
received) during the UTRAN
SRVCC execution
Y CC event int 0~2147483647 - -
UtranSrvccOutFail_S1
AP_SIG_FAIL
count A call is released due to
receiving S1AP signaling during
the UTRAN SRVCC execution
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 172 of 427
2600-00FET7GAT 6.0
6.4 CS Fall Back (CSFB) PS Handover OUT
This section provides statistics for CSFB with PS handover count between the LTE and UTRAN for each cell.
Steps Description
1 The UE transmits the Extended Service Request message to the MME through the NAS procedure.
1b, 1c If the CS Fallback indicator is encapsulated in the Initial Context Setup Request and UE Context Modification Request, the eNB transmits
the Initial Context Setup Response and UE Context Modification Response message to the MME, and prepares for CS fallback.
2 The RRC Connection Reconfiguration message that encapsulates the periodic report information is transmitted to the UE; and handover
procedure starts when the periodic measurement report is received.
3 The procedure after this is the same as that of inter-RAT handover-LTE to UTRAN PS handover.
Index
Name Range Description
cNum 0~2 Source Cell Index
CSFBIndicator 0~1 CSFB Indicator
0: Normal
1: High priority
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 173 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CsfbPsHoAttUTR
AN
count Attempt count for CSFB with inter-
RAT UTRAN PS handover.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepSu
ccUTRAN
count Success count for CSFB with inter-
RAT UTRAN PS handover
preparation.
Y CC event int 0-2147483647 - -
CsfbPsHoSuccUT
RAN
count Success count for CSFB with inter-
RAT UTRAN PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepFai
lUTRAN_CP_CC
_FAIL
count Preparation fails due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the CSFB PS
handover preparation.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepFai
lUTRAN_S1AP_C
U_FAIL
count Preparation fails due to S1AP
specification cause during the
CSFB PS handover preparation.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepFai
lUTRAN_S1AP_L
INK_FAIL
count Preparation fails due to S1 SCTP
link failure during the CSFB PS
handover preparation.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepFai
lUTRAN_S1AP_R
P_TO
count Preparation fails due to S1AP
relocprep timeout (not received)
during the CSFB PS handover
preparation.
Y CC event int 0-2147483647 - -
CsfbPsHoPrepFai
lUTRAN_S1AP_S
count Preparation fails due to receiving
S1AP signaling during the CSFB
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 174 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IG_FAIL PS handover preparation.
CsfbPsHoFailUT
RAN_CP_CC_TO
count A call is released due to call control
timeout in the protocol blocks
(MAC, RLC, PDCP, GTP) during
the CSFB PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_CP_CC_FA
IL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the
ECCB block during the CSFB PS
handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_UP_GTP_F
AIL
count A call is released due to the failure
in the GTP block during the CSFB
PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_UP_MAC_F
AIL
count A call is released due to the failure
in the MAC block during the CSFB
PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_UP_PDCP_
FAIL
count A call is released due to the failure
in the PDCP block during the
CSFB PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_UP_RLC_F
AIL
count A call is released due to the failure
in the RLC block during the CSFB
PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_RRC_SIG_
FAIL
count A call is released due to receiving
RRC signaling during the CSFB PS
handover execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 175 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CsfbPsHoFailUT
RAN_S1AP_CU_
FAIL
count A call is released due to the S1AP
specification cause during the
CSFB PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_S1AP_LINK
_FAIL
count A call is released due to the S1
SCTP link failure during the CSFB
PS handover execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_S1AP_RO_
TO
count A call is released due to S1AP
relocoverall timeout (not received)
during the CSFB PS handover
execution.
Y CC event int 0-2147483647 - -
CsfbPsHoFailUT
RAN_S1AP_SIG_
FAIL
count A call is released due to receiving
S1AP signaling during the CSFB
PS handover execution.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 176 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 30. Collection Time for CSFB PS Handover Out
For CSFB PS handover UTRAN out statistics, when the S1 Handover Required message can be transmitted to the MME after the han
dover UTRAN decision following the Measurement Report message arrival, it is counted as Attempt; when the S1 Handover Command
message is received from the MME, it is counted as Prepare. The source eNB transmits the Mobility From EUTRA Command messa
ge to the UE, and the MME transmits the S1 UE Context Release Command message to the source eNB. At this point, the source eN
B is counted as Success.
If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai
ls, it is counted as CSFB PS HO UTRAN Out, returning the cause value.
UE Source eNB MME
Solicit Measurement Report
Call Release
1 1 Attempt
1 3 Success
1 2 Prepare
Initial Context Setup Request (with CSFB Ind)
or UE Context Modification Request (with CSFB Ind)
Mobility From EUTRA Command
Handover Required
Handover Command
UE Context Release Command
UE Context Release Complete
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 177 of 427
2600-00FET7GAT 6.0
6.5 CS FallBack (CSFB) without PS Handover Out (Redirection)
This section provides statistics for CSFB with Redirection count between the LTE and UTRAN for each cell.
Index
Name Range Description
cNum 0~2 Source Cell Index
CSFBIndicator 0~1 CSFB Indicator
0: Normal
1: High priority
SIBOwn 0~1 Indicates whether UTRAN SI information is included.
0: Not included
1: Included
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CsfbRedirAttUTRAN count CSFB with Redirection to inter-
RAT UTRAN attempt count
Y CC event int 0-2147483647 - -
CsfbRedirPrepSuc
cUTRAN
count CSFB with Redirection to inter-
RAT UTRAN preparation
success count.
Y CC event int 0-2147483647 - -
CsfbRedirSuccUT
RAN
count CSFB with Redirection to inter-
RAT UTRAN execution
success count.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 178 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 31. Collection Time for CSFB Redirection Out
For CSFB with Redirection UTRAN statistics, when the Initial Context Setup Request or UE Context Modification Request message re
ceived has the CSFB Indicator IE, according to which CSFB is decided, it is counted as Attempt; when preparation is completed in th
e eNB, it is counted as Prepare. Success is counted when the RRC Connection Release message is transmitted to the UE for redirectio
n.
UE Source eNB MME
Call Release
1 1 Attempt
1 3 Success
1 2 Prepare
Initial Context Setup Request (with CSFB Ind)
or UE Context Modification Request (with CSFB Ind)
RRC connection Release (with Redirection Info)
Initial Context Setup Response
or UE Context Modification Response
Redirection
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 179 of 427
2600-00FET7GAT 6.0
6.6 PS Redirection UTRAN Out
Collects statistics data for PS redirection between the LTE system and UTRAN for each cell.
Index
Name Range Description
cNum 0~2 Source Cell Index
HOCause 0~1 Handover Cause
0: handover desirable for radio reasons
1: reserved
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PsRedirAttUTRAN count PS Redirection to Inter RAT
UTRAN attempt count
Y CC event int 0~2147483647 - -
PsRedirPrepSuccUT
RAN
count PS Redirection to Inter RAT
UTRAN preparation success
count
Y CC event int 0~2147483647 - -
PsRedirSuccUTRAN count PS Redirection to Inter RAT
UTRAN execution success
count
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 180 of 427
2600-00FET7GAT 6.0
7 CSL Call Summary Log (CSL) is counted when the call is dropped. It can be used to collect various information and actual release cause f
or the call for example ‘Call Release Cause’. These statistics items are described in the following table.
7.1 Call Fail Report
This section provides statistics data for the CSL. The CSL statistics are collected when the call is released, and can help identify the a
ctual cause of the call release.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
No_FAULT count The call is terminated normally. Y CC event int 0-2147483647 - -
S1AP_CauseRadioN
etwork_unspecified
count During handover, the target eNB
transmits the Path Switch Request
message, and then does not
receive the Path Switch Response,
but receives the UE Context
Release Command message.
Y CC event int 0-2147483647 - -
S1AP_tx2relocoveral count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 181 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
l_expiry
S1AP_successful_h
andover
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_release_due_
to_eutran_generated
_reason
count A call is released due to redirection
when MR is received from the UE.
Y CC event int 0-2147483647 - -
S1AP_handover_ca
ncelled
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_partial_hando
ver
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_ho_failure_in
_target_EPC_eNB_o
r_target_system
count When a failure cause is received
from target system as the Forward
Relocation Response during Inter-
MME/Inter-RAT S1 handover, it is
transmitted by being specified in
the Handover Preparation Failure.
Y CC event int 0-2147483647 - -
S1AP_ho_target_not
_allowed
count If S1 handover fails due to
AccessRestriction (Utran Not
Allow, etc.) of the UE, it is
transmitted by being specified in
the Handover Preparation Failure.
Y CC event int 0-2147483647 - -
S1AP_tS1relocovera
ll_expiry
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_tS1relocprep_
expiry
count In S1_OUT statistics event, when
the timer waiting for the handover
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 182 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
command expires after the source
eNB transmits the Handover
Required message.
S1AP_cell_not_avail
able
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_tar
getID
count When it is not possible to find the
TAI information for the TargetID
received via the Handover
Required or the remote MME
information, it is transmitted by
being specified in the Handover
Preparation Failure.
Y CC event int 0-2147483647 - -
S1AP_no_radio_res
ources_available_in
_target_cell
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_mm
e_ue_s1ap_id
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_enb
_ue_s1ap_id
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_pair
_ue_s1ap_id
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_handover_de
sirable_for_radio_re
ason
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_time_critical_ count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 183 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
handover
S1AP_resource_opti
misation_handover
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_reduce_load_
in_serving_cell
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_user_inactivit
y
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_radio_connec
tion_with_ue_lost
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_load_balancin
g_tau_required
count When the RLB value of MME-INF
is changed to other value than
NONE, it is transmitted by being
specified in the UE context release
command for MME re-load
balancing.
Y CC event int 0-2147483647 - -
S1AP_cs_fallback_tr
iggered
count A call is released due to CSFB that
causes the inter-RAT redirection.
Y CC event int 0-2147483647 - -
S1AP_ue_not_availa
ble_for_ps_service
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_radio_resourc
es_not_available
count A call is released due to resource
allocation failure in eNB for the
bearer where setup is requested
by the MME.
Y CC event int 0-2147483647 - -
S1AP_failure_in_rad
io_interface_procedu
count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 184 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
re
S1AP_invalid_qos_c
ombination
count - When gbrType of QCI received
within
E_RABLevelQoSParameters IE
of the Initial Context Setup
Request message is GBR but the
gbrQosInformation received is the
‘not present’ message
- When gbrType of QCI received
within
E_RABLevelQoSParameters IE
of the E_RAB Setup Request
message is GBR but the
gbrQosInformation received is the
‘not present’ message
- When gbrType of QCI received
within
E_RABLevelQoSParameters IE
of the E_RAB Modify Request
message is GBR but the
gbrQosInformation received is the
‘not present’ message
Y CC event int 0-2147483647 - -
S1AP_interrat_redire
ction
count A call is released due to the inter-
RAT redirection.
It occurs when redirection is
processed normally due to the
inter-RAT redirection.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 185 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1AP_interaction_wi
th_other_procedure
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_E_
RAB_ID
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_multiple_E_R
AB_ID_instances
count A call is released due to receiving
the information with the same
ERAB ID after the Initial Context
Setup Request message is
received.
Y CC event int 0-2147483647 - -
S1AP_encryption_a
nd_or_integrity_prot
ection_algorithms_n
ot_supported
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_s1_intra_syst
em_handover_trigge
red
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_s1_inter_syst
em_handover_trigge
red
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_x2_handover
_triggered
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_redirection_to
wards_1xRTT
count A call is released due to redirection
to 1xRTT.
Y CC event int 0-2147483647 - -
S1AP_not_supporte
d_QCI_value
count A call is released due to receiving
the QCI value not supported by
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 186 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
eNB through the Initial Context
Setup Request message.
S1AP_invalid_CSG_
Id
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_transport_reso
urce_unavailable
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_CauseTransp
ort_unspecified
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_normal_relea
se
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_authentication
_failure
count MME transmits the UE Context
Release Command message
including the cause value due to
the UE authentication failure
during the attach.
Y CC event int 0-2147483647 - -
S1AP_detach count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_CauseNas_u
nspecified
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_csg_subscript
ion_expiry
count If S1 is released because the UE
whose location was registered in
the CSG area has no or expired
CSG subscription, the UE Context
Release command is transmitted.
The CSG-related causes will be
supported later.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 187 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1AP_transfer_synt
ax_error
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_abstract_synt
ax_error_reject
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_abstract_synt
ax_error_ignore_and
_notify
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_message_not
_compatible_with_re
ceiver_state
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_semantic_err
or
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_abstract_synt
ax_error_falsely_con
structed_message
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_CauseProtoc
ol_unspecified
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_control_proce
ssing_overload
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_not_enough_
user_plane_processi
ng_resources
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_hardware_fail
ure
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_om_interventi count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 188 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
on
S1AP_CauseMisc_u
nspecified
count Currently not in use. Y CC event int 0-2147483647 - -
S1AP_unknown_PL
MN
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_handover_de
sirable_for_radio_re
asons
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_time_critical_
handover
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_resource_opti
misation_handover
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_reduce_load_
in_serving_cell
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_partial_hando
ver
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_unknown_ne
w_eNB_UE_X2AP_I
D
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_unknown_old
_eNB_UE_X2AP_ID
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_unknown_pair
_of_UE_X2AP_ID
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_ho_target_not
_allowed
count If the DRB CAC procedure fails in
the target during X2 handover, this
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 189 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
will be included in the X2_IN and
X2_OUT preparation fail statistics.
X2AP_tx2relocoveral
l_expiry
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_trelocprep_ex
piry
count If the Handover Request
Acknowledge message is not
received from the target eNB
during X2 handover, this will be
included in the X2_OUT
preparation fail statistics of the
source eNB.
Y CC event int 0-2147483647 - -
X2AP_cell_not_availa
ble
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_no_radio_res
ources_available_in
_target_cell
count If the cell information
corresponding to the target ID
transmitted via the handover
request message is not found in
the target eNB, this will be included
in the X2_IN and X2_OUT
preparation fail statistics.
Y CC event int 0-2147483647 - -
X2AP_invalid_MME
_GroupID
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_unknown_MM
E_Code
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_encryption_a
nd_or_integrity_prot
count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 190 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ection_algorithms_n
ot_supported
X2AP_reportCharact
eristicsEmpty
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_noReportPeri
odicity
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_existingMeas
urementID
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_unknown_eN
B_Measurement_ID
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_measurement
_temporarily_not_av
ailable
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_CauseRadioN
etwork_unspecified
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_load_balancin
g
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_handover_opt
imisation
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_value_out_of
_allowed_range
count A call is released when the QCI
value of the E-RAB level QoS
parameters is out of the range
specified in the specification during
bearer setup in the target eNB.
This will be included in the X2_IN
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 191 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
and X2_OUT preparation fail
statistics.
X2AP_multiple_E_R
AB_ID_instances
count A call is released when setup is
requested for the same ERAB ID
during bearer setup in the target
eNB. This will be included in the
X2_IN and X2_OUT preparation
fail statistics.
Y CC event int 0-2147483647 - -
X2AP_switch_off_on
going
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_transport_res
ource_unavailable
count A call is released when the internal
resource setup fails in the target
eNB during X2 handover; this will
be included in the X2 IN
Preparation Fail cause.
Y CC event int 0-2147483647 - -
X2AP_CauseTransp
ort_unspecified
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_transfer_synt
ax_error
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_abstract_synt
ax_error_reject
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_abstract_synt
ax_error_ignore_and
_notify
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_message_not count Currently not in use. Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 192 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
_compatible_with_re
ceiver_state
X2AP_semantic_err
or
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_CauseProtoc
ol_unspecified
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_abstract_synt
ax_error_falsely_con
structed_message
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_control_proce
ssing_overload
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_hardware_fail
ure
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_om_interventi
on
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_not_enough_
user_plane_processi
ng_resources
count Currently not in use. Y CC event int 0-2147483647 - -
X2AP_CauseMisc_u
nspecified
count The Handover Cancel message is
transmitted to the target eNB due
to reestablishment to the source
eNB during X2 handover. This call
release will be included the X2_IN
Fail statistics.
Y CC event int 0-2147483647 - -
ECC_TMOUT_rrcCo count A call is released when the RRC Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 193 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
nnectionSetupCompl
ete
Connection Setup Complete
message is not received after the
RRC Connection Setup message
is transmitted to the UE.
ECC_TMOUT_rrcCo
nnectionReconfigCo
mplete
count A call is released when the RRC
Connection Reconfiguration
Complete message is not received
after transmitting the RRC
Connection Reconfiguration
message.
Y CC event int 0-2147483647 - -
ECC_TMOUT_rrcCon
nectionReEstablishCo
mplete
count A call is released when the RRC
Connection Reestablishment
Complete message is not received
from the UE after transmitting the
RRC Connection Reestablishment
message to the UE.
Y CC event int 0-2147483647 - -
ECC_TMOUT_rrcSe
curityModeComplete
count A call is released when the
Security Mode Complete message
is not received after the Security
Mode Command message is
transmitted to the UE.
Y CC event int 0-2147483647 - -
ECC_TMOUT_rrcUe
CapabilityInformatio
n
count A call is released when the UE
Capability Information message is
not received after the UE
Capability Enquiry message is
transmitted to the UE.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 194 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ECC_TMOUT_rrcHa
ndoverPreparation
count A call is released when the UL
Handover Preparation Transfer
message is not received after
transmitting the Handover From
EUTRA Preparation Request
during the Inter RAT HRPD
handover.
Not applicable to the service
provider who does not use the
HRPD handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intra_
HandoverCmdCompl
ete
count A call is released when the target
cell cannot receive the RRC
Connection Reconfiguration
Complete message during the
intra-handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_inter_
X2HandoverCmdCo
mplete
count A call is released when the target
eNB cannot receive the RRC
Connection Reconfiguration
Complete message during the X2
handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_inter_
S1HandoverCmdCo
mplete
count A call is released when the target
eNB cannot receive the RRC
Connection Reconfiguration
Complete message during the S1
handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_s1Init count A call is released when the Initial Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 195 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ialContextSetupReq
uest
Context Setup Request message
is not received after transmitting
the Initial UE message to the
MME.
ECC_TMOUT_s1Pat
hSwitchAck
count A call is released when the Path
Switch Request Acknowledge
message is not received after the
target eNB transmits the Path
Switch Request message during
the X2 handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_s1Ha
ndoverPreparation
count A call is released when
DownlinkS1cdma2000tunneling
message is not received after
transmitting the
UplinkS1cdma2000tunneling
message to MME during the Inter
RAT HRPD handover.
Not applicable to the service
provider who does not use the
HRPD handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_s1Rel
ocOverall
count A call is released when a
RelocOverall Timeout occurs in the
source eNB during the S1
handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_s1M
MEStatusTransfer
count A call is released when the target
eNB cannot receive the MME
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 196 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Status Transfer message after the
source eNB transmits the eNB
Status Transfer message to the
MME.
ECC_TMOUT_x2Rel
ocOverall
count A call is released when a
RelocOverall Timeout occurs in the
source eNB during the X2
handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_x2SN
StatusTransfer
count A call is released when the target
eNB cannot receive the X2 SN
Status Transfer message
transmitted from the source eNB.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intern
alResourceSetup
count A response message is not
received after the SetupReq
message is transmitted to allocate
resources to the protocol blocks
within the eNB.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intern
alSecurityControl
count A call is released when a response
is not received from the PDCB
block while transferring the
security information to eNB’s
internal PDCB block during attach
procedure.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intern
alForwardingPathSet
up
count A call is released when no
response is received for the
request of uplink and downlink
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 197 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
path setup between the ECCB
block and the eNB’s internal block
GTPB during handover.
ECC_TMOUT_intern
alReestablishControl
cunt A call is released when no
response message is received
from RLCB and PDCB blocks
while configuring the eNB’s ECCB
block and internal RLCB & PDCB
blocks for RLC and PDCP
Reestablishment during X2/S1
handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intern
alBufferFlush
count A call is released when no
response message is received
from PDCB while interfacing
between ECCB and PDCB for
buffer flush during handover.
Y CC event int 0-2147483647 - -
ECC_TMOUT_intern
alDataTransferStart
count A call is released when PDCP
setup fails in the target eNB during
handover.
Y CC event int 0-2147483647 - -
ECC_USER_INACTI
VITY
count A call is released due to no traffic
transmission during the given
period of time (user inactivity time)
for a specific UE when the MACB
block detects the user inactivity,
and notifies the fact to the ECCB
block.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 198 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ECC_ARQ_MAX_R
E_TRANSMISSION
count A call is released when the RLCB
block made transmission to the UE
as many times as the Max
Retransmission, but ARQ ACK is
not received from the UE, which is
notified to the ECCB.
Y CC event int 0-2147483647 - -
ECC_RADIO_LINK_
FAILURE
count When the MACB determines the
Sync disconnection with the UE, it
notifies the ECCB of OutOfSync. If
the ECCB is notified of the MACB
of being InSync again (HARQ-
ACK/NACK received 20 times), or
if it fails to receive the RRC
Connection Reestablishment
Request from the UE, the call is
released after a timeout (default: 5
seconds).
Y CC event int 0-2147483647 - -
ECC_UE_CONTEX
T_NOT_FOUND
count Although the UE requested the
Reestablishment, cannot perform
Reestablishment because could
not find the UE Context information
in eNB.
Y CC event int 0-2147483647 - -
ECC_S1AP_SN_ST
ATUS_NOT_RECEI
VED
count If the RRC Connection
Reestablishment Request
message is received while waiting
for the SN Status Transfer
message from the source eNB or
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 199 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
the MME Status Transfer message
from the MME, the RRC
Connection Reestablishment
Reject message is transmitted to
the UE.
ECC_REEST_FAIL_
INVALID_STATE
count If the RRC Connection
Reestablishment Request
message is received during Attach,
the eNB detects that
reestablishment occurs while the
DRB setup is not normal, and
releases the call.
Y CC event int 0-2147483647 - -
ECC_CDMA_HAND
OVER_PREPARATI
ON_FAILURE
count A call is released when the UL
Handover Preparation Transfer
message is not received after
transmitting the Handover From
EUTRA Preparation Request
during the Inter RAT HRPD
handover.
Y CC event int 0-2147483647 - -
ECC_RCV_S1_UEC
TXTRELEASECMD_
ABNORMAL_STATE
count A call is released when the UE
Context Release Command
message is received when the UE
Associated setup is not made with
the MME. If this cause occurs, it is
necessary to check the cause
value delivered to the MME.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 200 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ECC_RCV_RESET_
REQUEST_FROM_
ECMB
count A call is released due to receiving
a reset request from ECMB due to
refork of a specific block in eNB.
Y CC event int 0-2147483647 - -
ECC_RCV_S1_RES
ET_FROM_MME
count The call in the handover process is
released by receiving a reset
message from the MME.
Y CC event int 0-2147483647 - -
ECC_RCV_X2_RES
ETREQUEST
count A call is released due to the
reception of the Reset Request
message from other eNB.
Y CC event int 0-2147483647 - -
ECC_S1_SCTP_OU
T_OF_SERVICE
count A call is released when the S1
Association’s status is changed
from In Service to Out of Service
state.
Y CC event int 0-2147483647 - -
ECC_RCV_CELL_R
ELEASE_IND_FRO
M_ECMB
count A call is released due to the Cell
Release Ind message received
from the ECMB block because of
DSP down or CPRI failure caused
by DSP problem. (CPRI deleted)
Y CC event int 0-2147483647 - -
ECC_DSP_AUDIT_
RLC_CALL_RELEA
SE
count A call is released when the call
remains in the ECCB and MACB,
but not in the RLCB, which causes
resource mismatch.
Y CC event int 0-2147483647 - -
ECC_DSP_AUDIT_
MAC_CALL_RELEA
SE
count A call is released when the call
remains in the ECCB and RLC, but
not in the MACB, which causes
resource mismatch.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 201 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ECC_DSP_AUDIT_R
LC_MAC_CALL_REL
EASE
count A call is released when the call
remains in the ECCB, but not in
the RLC and MAC, which causes
resource mismatch.
Y CC event int 0-2147483647 - -
ECC_S_ALGORITH
MS_COMBINATION
_INVALID
count The security algorithm value is
received in the Initial Context
Setup Request, S1 Handover
Request, X2 Handover Request,
S1 UE Context Modification
message.
A call is released when the
ciphering algorithm does not have
the null algorithm value if the
integrity algorithm supports the null
algorithm.
Y CC event int 0-2147483647 - -
ECC_X2_SCTP_OU
T_OF_SERVICE
count A call is released when the X2
Association’s status is changed
from In Service to Out of Service
state.
Y CC event int 0-2147483647 - -
ECC_RELEASE_DU
E_TO_ENB_GENER
ATED_REASON
count A call is released due to the
internal cause in eNB.
Y CC event int 0-2147483647 - -
ECC_INTER_FA_R
EDIRECTION
count When processing the redirection to
the inter FA (If it conflicts with the
CRR output conditions based on
the S1AP cause, the CRR in the
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 202 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
column D (Call Release Cause) is
displayed.)
ECC_CSFB_CONFI
G_FAILURE
count A call is released when, even if
CSFB was triggered by the
InitialContextSetupRequest
message, the CSFB redirection
cannot be processed due to eNB
setting error (Inter RAT FA
information not specified).
Y CC event int 0-2147483647 - -
RRM_FAIL count The DB initialization procedure
managed by the ERRM fails.
Y CC event int 0-2147483647 - -
RRM_CELL_BARRED count A call is released when RRC
Connection Reject message is
transmitted due to call rejection
because the relevant cell is barred
even when the RRC Connection
Request message is received.
Y CC event int 0-2147483647 - -
RRM_MAX_CALL_C
OUNT_OVER
count When calls are generated
exceeding the number of calls that
can be accommodated, they are
rejected by CAC.
Y CC event int 0-2147483647 - -
RRM_MAX_DRB_C
OUNT_OVER
count When calls are generated
exceeding the number of DRB that
can be accommodated by cell,
they are rejected by CAC.
Y CC event int 0-2147483647 - -
RRM_QOSCAC_FAIL count The call with the QoS that cannot Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 203 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
be allowed by the cell is
generated; it is rejected by CAC.
RRM_PREEMPTIO
N_FAIL
count Preemption fails because the
requested ERAB’s priority is under
the priority of the existing UE.
Y CC event int 0-2147483647 - -
RRM_CALLRSC_FA
IL
count Call ID is all assigned thus Call ID
cannot be assigned any more.
Y CC event int 0-2147483647 - -
RRM_BHCAC_FAIL count A call is released when the BH link
usage by a specific QoS (GBR
Bearer) exceeds the threshold
defined in the PLD.
Y CC event int 0-2147483647 - -
RRM_SRSRSC_FAIL count When a new call supports both
SRS and DRX, the SRS resources
need to assigned in advance to
assign the DRX resources but the
DRX resources cannot be
assigned because the SRS
resource is not assigned.
Y CC event int 0-2147483647 - -
RRM_CQIRSC_FAIL count CQI/PMI resources are all
assigned thus cannot assign the
resource any more.
Y CC event int 0-2147483647 - -
RRM_SPSRSC_FAIL count SPS resources are all assigned
thus the SPS resource cannot be
assigned any more.
Y CC event int 0-2147483647 - -
RRM_N1PUCCHRS
C_FAIL
count n1PucchAnRep resources are all
assigned thus the resource cannot
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 204 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
be assigned any more.
RRM_SRRSC_FAIL count During SR resource allocation and
release, the SR resource search is
not allowed to exceed the Max
value of the SR resource DB.
Y CC event int 0-2147483647 - -
RRM_TPCRSC_FAIL count During TPC PUCCH RNTI
resource allocation and release,
the TPC PUCCH resource search
is not allowed to exceed the Max
value of TPC PUCCH resource
DB.
Y CC event int 0-2147483647 - -
RRM_ALL_MME_N
OT_SERVICE
count A call is rejected because there
exists no MME currently in
connection.
Y CC event int 0-2147483647 - -
RRM_MME_OVERL
OAD
count When the MME is in Overload
status, cannot accommodate the
calls because overloadAction and
establishmentCause does not
match.
Y CC event int 0-2147483647 - -
RRM_NOT_EXIST_
MME
count The registered MME information
that the UE informs in the RRC
Connection Setup Complete
message does not exist in the eNB
database.
Y CC event int 0-2147483647 - -
RRM_AVAILABLE_
MME_NOT_EXIST
count The MME with the PLMN value
informed by the UE does not exist
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 205 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
in the RRC Connection Setup
Complete message.
RRM_UE_STMSI_D
UPLICATE
count The same UE transmits the RRC
Connection Request with the same
S-TMSI value.
Y CC event int 0-2147483647 - -
GTP_SETIP_FAIL count A call is released when a response
to GTP Setup Fail is transmitted
after the SetupReq message is
received from the ECCB.
Tunnel information error managed
by the GTPB block and tunnel
setting failure due to DB
management error are notified to
the ECCB.
Y CC event int 0-2147483647 - -
GTP_RELEASE_FAIL count An error response is generated
when GTP Release fails.
Y CC event int 0-2147483647 - -
GTP_MODIFY_FAIL count A call is released when a response
to GTP Modify Fail is transmitted
after the ModifyReq message is
received from the ECCB.
Tunnel information error managed
by the GTPB block and tunnel
setting failure due to DB
management error are notified to
the ECCB.
Y CC event int 0-2147483647 - -
GTP_RESET_FAIL count A call is released if there is Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 206 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
response for Gtp setup fail after
receiving the ModifyReq message
from the ECMB.
GTP_PATH_FAIL count If there is no Echo Response
within 60 seconds after Echo
Request is transmitted periodically
to the peer node of the EPS bearer,
the request is retransmitted five
times at the interval of 5 seconds.
If there is still no response, ECCB
receives the response indicating a
path to the peer node is abnormal.
The GTPB block determines that a
bearer path to the peer node is
abnormal or GTP entity within the
peer node is abnormal and notifies
the ECCB block of the failure.
Y CC event int 0-2147483647 - -
GTP_NOT_SUPPO
RT_EH
count Send a response when receiving
the message with the extension
header that cannot be supported
by the system from dst peer during
tunnel setup.
Y CC event int 0-2147483647 - -
GTP_RCV_ERROR
_IND_FROM_GW
count A bearer is released when an error
indication message is received
from the peer node of GTPB,
which is notified to the ECCB.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 207 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PDCP_INVALID_CAL
LID
count An error response is generated
when the callid of the downloaded
message from the ECCB is the
value of the MAX_USER_ENB or
higher.
Y CC event int 0-2147483647 - -
PDCP_INVALID_RB
ID
count When Rbid of the message
received from ECCB is MAX_RB
or less for PDCP_DRB and
MAX_SRB or less for PDCP_SRB,
the message is normal. Otherwise,
an error response is generated.
There is no possibility that it will a
CSL cause.
Y CC event int 0-2147483647 - -
PDCP_INVALID_NU
MOFRB
count An error response is generated
when the NumRb of the
downloaded message from the
ECCB is the value of the
CI_MAX_RB or higher.
Y CC event int 0-2147483647 - -
PDCP_INVALID_RL
CMODE
count An error response is generated
when the RLC mode of the
message downloaded from the
ECCB is invalid.
Y CC event int 0-2147483647 - -
PDCP_INVALID_SE
TUPTYPE
count An error response is generated
when the setupType of the
message downloaded from the
ECCB is invalid.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 208 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PDCP_INVALID_CN
TLTYPE
count An error response is generated
when the CntlType of the message
downloaded from the ECCB is
invalid.
Y CC event int 0-2147483647 - -
PDCP_INVALID_PD
CPSNTYPE
count An error response is generated
when the SNType of the message
downloaded from the ECCB is UM,
but not 7-bit or 12-bit.
Y CC event int 0-2147483647 - -
PDCP_INVALID_LO
CHTYPE
count An error response is generated
when the logical type of the
message downloaded from the
ECCB is other than either
LOCH_DCCH (for the SRB) or
LOCH_DTCH (for the DRB).
There is no possibility that it will a
CSL cause.
Y CC event int 0-2147483647 - -
PDCP_ROHC_SET
UP_FAIL
count An error response is generated
when the ROHC context setup
procedure fails due to lack of
memory while receiving ConfigReq
from the ECCB.
Y CC event int 0-2147483647 - -
PDCP_INACTIVATE
_RBID
count A call is released when the
message on Inactive RB is
received while receiving the
msgCpdcpModifyReq from the
ECCB
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 209 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PDCP_SRB_INTEG
RITY_FAIL
count A call is released when SRB’s
integrity check failure notification is
received from the PDCB.
Y CC event int 0-2147483647 - -
RLC_INVALID_PAR
AMETER
count An error response is generated
when the parameter of the
message received from the ECCB
is not the value within the defined
range.
Y CC event int 0-2147483647 - -
RLC_NO_MORE_R
ESOURCE
count An error response is generated
when a new connection cannot be
allowed due to insufficient
resources to be allocated to the
message received from the ECCB.
Y CC event int 0-2147483647 - -
RLC_CELL_IS_IDLE count An error response is generated
when cell ID status of the message
received from the ECCB is IDLE,
not ACTIVE.
Y CC event int 0-2147483647 - -
RLC_CALL_IS_NOT
_ACTIVE
count An error response is generated
when the call ID status of the
message received from the ECCB
is not ACTIVE.
Y CC event int 0-2147483647 - -
RLC_ERROR_EMP
TY_MSG
count An error response is generated
when the message received by the
RLC is NULL.
Y CC event int 0-2147483647 - -
RLC_ERROR_UNK
NOWN_MSG_ID
count An error response is generated
when the type of the message
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 210 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
received by the RLC is unknown
RLC_ERROR_INVA
LID_DATA_LEN
count An error response is generated
when the size of the message
received by the RLC is abnormal.
Y CC event int 0-2147483647 - -
RLC_ERROR_NO_
RSP_FROM_DL
count An error response is generated
when the RLC downlink does not
respond to the message received.
Y CC event int 0-2147483647 - -
RLC_ERROR_NO_
RSP_FROM_UL
count An error response is generated
when the RLC uplink does not
respond to the message received.
Y CC event int 0-2147483647 - -
RLC_ERROR_NO_
RSP_FROM_DLUL
count An error response is generated
when the RLC downlink and uplink
do not respond to the message
received.
Y CC event int 0-2147483647 - -
RLC_ERROR_RX_BE
FORE_RLC_READY
count An error response is generated
when the RLC uplink receives a
signaling message before it
operates properly.
Y CC event int 0-2147483647 - -
RLC_ERROR_INVA
LID_RLC_TRANSA
CTION_ID
count An error response is generated
when the transaction ID exceeds
the specified range while the RLC
processes the message received
from the ECCB.
Y CC event int 0-2147483647 - -
RLC_ERROR_INVA
LID_CONTEXT
count An error response is generated
when a response is retransmitted
from the RLC downlink for the
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 211 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
signaling message that the RLC
has already processed.
RLC_ERROR_RLC_
CONTEXT_FULL
count An error code is generated when
the number of the signaling
messages received exceeds the
capacity that the RLC can process.
Y CC event int 0-2147483647 - -
MAC_INVALID_MS
GID
count An undefined Message Id is
received.
Y CC event int 0-2147483647 - -
MAC_INVALID_SET
UPTYPE
count An undefined SetupType is
received.
Y CC event int 0-2147483647 - -
MAC_INVALID_CAL
L_CELLID
count When the ‘cell call ID’ value of the
message received from the ECCB
is outside the defined range.
Y CC event int 0-2147483647 - -
MAC_INVALID_PAR
AMETER
count When the parameter received is
outside the defined range.
Y CC event int 0-2147483647 - -
MAC_INSUFFICIEN
T_RESOURCE
count The RB cannot be allocated due to
insufficient MACB internal resource
required to manage the RB.
Y CC event int 0-2147483647 - -
MAC_NOT_ASSIGN
ED_RB
count A reconfig/delete request is
received for the RB that is not
allocated.
Y CC event int 0-2147483647 - -
MAC_NOT_ASSIGN
ED_UE
count A config/delete request is received
for the UE that is not allocated.
Y CC event int 0-2147483647 - -
MAC_NOT_ASSIGN
_SRB1
count When the call setup message is
received without SRB1 setup.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 212 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
MAC_INVALID_RB_
CONFIG
count When the RB number within the
Logical Channel Config exceeds
the maximum value.
Y CC event int 0-2147483647 - -
MAC_INVALID_CELL
_ID
count When the cell that corresponds to
the received message is idle.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 213 of 427
2600-00FET7GAT 6.0
8 MRO_RLF Mobility Robustness Optimization (MRO) statistics are intended to collect and classify handover issues due to Radio Link Failure (RL
F) occurring during or after a handover, and use them in the MRO algorithm to optimize handover parameters (e.g. Cell Individual Off
set) and improve the handover performance.
8.1 MRO RLF Classification
The causes of the handover related RLF recorded as MRO issue are: too-late handover, too-early handover, and handover to a wrong c
ell.
The causes of RLF not recorded as a MRO issue, are recorded as coverage hole.
Index
Name Range Description
cNum 0~2 Cell Index
Neighbor cell 0~268435455 Neighbor cell index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CoverageHole count Number of RLF/HO failures due to
the coverage hole
Y CC event int 0-2147483647 - -
CoverageHoleN count Number of RLF/HO failures due to
the coverage hole toward Cell N
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 214 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TooEarlyHOFailu
re
count The number of too-early handovers
after transmitting the handover
command
Y CC event int 0-2147483647 - -
TooEarlyHORLF
AfterHO
count The number of too-early handovers
after completing the handover
process.
Y CC event int 0-2147483647 - -
TooLateHORLF
BeforeTriggering
count The number of RLFs before
triggering the handover.
Y CC event int 0-2147483647 - -
TooLateHORLFA
fterTriggering
count The number of RLFs after the
handover command is transmitted.
Y CC event int 0-2147483647 - -
WrongCellRLFAf
terTriggering
count The number of handovers to a
wrong cell before transmitting the
handover command.
Y CC event int 0-2147483647 - -
WrongCellRLFAf
terHO
count The number of handovers to a
wrong cell after transmitting the
handover command.
Y CC event int 0-2147483647 - -
BlackCellRLFAft
erHO
count The number of handovers to a black
cell RLF after HO (X2)
Y CC event int 0-2147483647 - -
PingpongHando
ver
count The number of ping-pong handovers
detected by the ping-pong detection
algorithm.
Y CC event int 0-2147483647 - -
MroRlfCnt count MRO RLF Classification collection
count
CC event int 0~214748364
7
- -
MroRlfCid Neighbor
Cell ID
NeighborCell ID of which collection
is requested
OW event int 0~214748364
7
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 215 of 427
2600-00FET7GAT 6.0
9 GTP The GPRS Tunneling Protocol Block (GTPB) handles the GPRS Tunneling Protocol for data access from the S1-U or X2-U, manages
the GTP tunnels for the E-RAB, and transmits/receives user data. GTP statistics are on the GTP layer packets that are received from t
he S1-U (S-GW) over the downlink, which allow the operator to detect the backhaul condition.
9.1 GTP Sequence Number by QCI
This section provides statistics data for the count of lost downlink packets and the count of Out of Sequence downlink packets in the
GTP layer.
Index
Name Range Description
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
GtpSnPeakLoss
Qci
count Count of downlink GTP packets which
have been regarded to be lost until the
statistics collection time.
Y CC 2 s. int 0-2147483647 - -
GtpSnOosQci count Count of Out of Sequence downlink
packets (i.e. the accumulated count of
packets which order of the GTP
Sequence Number is reversed) for each
QCI.
Y CC 2 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 216 of 427
2600-00FET7GAT 6.0
9.2 GTP Sequence Number by eNB
This section provides statistics data for the count of lost downlink packets and the count of Out of Sequence downlink packets in the
GTP layer for the eNB.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
GtpSnPeakLoss
Enb
count Count of downlink GTP
packets which have been
regarded to be lost until the
statistics collection time.
Y CC 2 s. int 0-2147483647 - -
GtpSnOosEnb count Count of Out of Sequence
downlink packets (i.e. the
accumulated count of
packets which order of the
GTP Sequence Number is
reversed) for each QCI.
Y CC 2 s. int 0-2147483647 - -
GtpDlCntEnb count Number of the downlink
GTP packets received until
the time of counting the
statistic.
Y CC 2 s. int 0-2147483647 - -
GtpSnLossEnb
Rate
% Ratio of the downlink GTP
packets lost against the total
packets until the time of
collecting the statistics
* lost packet =
GtpSnPeakLossEnb
Y OW Period float 0-100 GtpSnPeakLossE
nb/(GtpDlCntEnb+
GtpSnPeakLossE
nb-GtpSnOosEnb)
*100
sum
(GtpSnPeakLossEnb)/
(sum (GtpDlCntEnb)+
sum
(GtpSnPeakLossEnb)
-sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 217 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
* total packet =
GtpDlCntEnb +
(GtpDlCntEnb -
GtpSnOosEnb)
(GtpSnOosEnb))*100
GtpSnOosEnbR
ate
% Total GTP Packet OOS rate
per eNB
Y OW Period float 0-100 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 218 of 427
2600-00FET7GAT 6.0
9.3 GTP Forward Traffic
The GTP Forward Traffic statistic is defined as the downlink/uplink count/byte/throughput of forwarding traffic during calls, S1/X2 han
dovers and inter-RAT S1/X2 handovers. In statistics items, DL is based on the received packets and UL is based on the transmitted pa
ckets.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CntGtpDlEnbS1
Nor
count Number of S1 downlink GTP
packets during the basis call.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbS1
Nor
count Number of S1 uplink GTP packets
during the basis call.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbS1
FW
count Number of forwarded packets
received in the S1 downlink during
the S1 handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbS1
FW
count Number of packets forwarded to the
S1 uplink during the S1 handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbX2
FW
count Number of forwarded packets
received in the X2 downlink during
the X2 handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbX2
FW
count Number of packets forwarded to the
X2 uplink during the X2 handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atUtraS1FW
count Number of forwarded packets
received in the S1 downlink during
the inter-RAT (UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 219 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CntGtpUlEnbIR
atUtraS1FW
count Number of packets forwarded to the
S1 uplink during the inter-RAT
(UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atUtraX2FW
count Number of forwarded packets
received in the X2 downlink during
the inter-RAT (UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbIR
atUtraX2FW
count Number of packets forwarded to the
X2 uplink during the inter-RAT
(UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atGeranS1FW
count Number of forwarded packets
received in the S1 downlink during
the inter-RAT (GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbIR
atGeranS1FW
count Number of packets forwarded to the
S1 uplink during the inter-RAT
(GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atGeranX2FW
count Number of forwarded packets
received in the X2 downlink during
the inter-RAT (GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbIR
atGeranX2FW
count Number of packets forwarded to the
X2 uplink during the inter-RAT
(GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atCdma2000Hrp
dS1FW
count Number of forwarded packets
received in the S1 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y CC 20 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 220 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CntGtpUlEnbIR
atCdma2000Hrp
dS1FW
count Number of packets forwarded to the
S1 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpDlEnbIR
atCdma2000Hrp
dX2FW
count Number of forwarded packets
received in the X2 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y CC 20 s. int 0-2147483647 - -
CntGtpUlEnbIR
atCdma2000Hrp
dX2FW
count Number of packets forwarded to the
X2 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbS
1Nor
Kbytes Bytes of S1 downlink GTP packets
during the basis call.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbS
1Nor
Kbytes Bytes of S1 uplink GTP packets
during the basis call.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbS
1FW
Kbytes Bytes of forwarded packets
received in the S1 downlink during
the S1 handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbS
1FW
Kbytes Bytes of packets forwarded to the
S1 uplink during the S1 handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbX
2FW
Kbytes Bytes of forwarded packets
received in the X2 downlink during
the X2 handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbX
2FW
Kbytes Bytes of packets forwarded to the
X2 uplink during the X2 handover.
Y CC 20 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 221 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ByteGtpDlEnbIR
atUtraS1FW
Kbytes Bytes of forwarded packets
received in the S1 downlink during
the inter-RAT (UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atUtraS1FW
Kbytes Bytes of packets forwarded to the
S1 uplink during the inter-RAT
(UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbIR
atUtraX2FW
Kbytes Bytes of forwarded packets
received in the X2 downlink during
the inter-RAT (UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atUtraX2FW
Kbytes Bytes of packets forwarded to the
X2 uplink during the inter-RAT
(UTRAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbIR
atGeranS1FW
Kbytes Bytes of forwarded packets
received in the S1 downlink during
the inter-RAT (GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atGeranS1FW
Kbytes Bytes of packets forwarded to the
S1 uplink during the inter-RAT
(GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbIR
atGeranX2FW
Kbytes Bytes of forwarded packets
received in the X2 downlink during
the inter-RAT (GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atGeranX2FW
Kbytes Bytes of packets forwarded to the
X2 uplink during the inter-RAT
(GERAN) handover.
Y CC 20 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 222 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ByteGtpDlEnbIR
atCdma2000Hrp
dS1FW
Kbytes Bytes of forwarded packets
received in the S1 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atCdma2000Hrp
dS1FW
Kbytes Bytes of packets forwarded to the
S1 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpDlEnbIR
atCdma2000Hrp
dX2FW
Kbytes Bytes of forwarded packets
received in the X2 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y CC 20 s. int 0-2147483647 - -
ByteGtpUlEnbIR
atCdma2000Hrp
dX2FW
Kbytes Bytes of packets forwarded to the
X2 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y CC 20 s. int 0-2147483647 - -
ThruGtpDlEnbS
1Nor
Kbps Throughput of S1 downlink GTP
packets during the basis call.
Y SI 20 s. float 0-3.4*10^38 ThruGtpDlE
nbS1NorTot
/ThruGtpDl
EnbS1NorC
nt
sum
(ThruGtpDlEnbS1
NorTot)/sum
(ThruGtpDlEnbS1
NorCnt)
ThruGtpDlEnbS
1NorTot
Kbps The sum of collected
ThruGtpDlEnbS1Nor
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbS
1NorCnt
count Collected ThruGtpDlEnbS1Nor
count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 223 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbS
1Nor
Kbps Throughput of S1 uplink GTP
packets during the basis call.
Y SI 20 s. float 0-3.4*10^38 ThruGtpUlE
nbS1NorTot
)/ThruGtpUl
EnbS1NorC
nt
sum
(ThruGtpUlEnbS1
NorTot)/sum
(ThruGtpUlEnbS1
NorCnt)
ThruGtpUlEnbS
1NorTot
Kbps The sum of collected
ThruGtpUlEnbS1Nor
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbS
1NorCnt
count Collected ThruGtpUlEnbS1Nor
count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbS
1FW
Kbps Throughput of forwarded packets
received in the S1 downlink during
the S1 handover.
Y SI 20 s. float 0-3.4*10^38 ThruGtpDlE
nbS1FWTot/
ThruGtpDlE
nbS1FWCnt
sum
(ThruGtpDlEnbS1
FWTot)/sum
(ThruGtpDlEnbS1
FWCnt)
ThruGtpDlEnbS
1FWTot
Kbps The sum of collected
ThruGtpDlEnbS1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbS
1FWCnt
count Collected ThruGtpDlEnbS1FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpUlEnbS
1FW
Kbps Throughput of packets forwarded to
the S1 uplink during the S1
handover.
Y SI 20 s. float - ThruGtpUlE
nbS1FWTot/
ThruGtpUlE
nbS1FWCnt
sum
(ThruGtpUlEnbS1
FWTot)/sum
(ThruGtpUlEnbS1
FWCnt)
ThruGtpUlEnbS
1FWTot
Kbps The sum of collected
ThruGtpUlEnbS1FW
- SI 20 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 224 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbS
1FWCnt
count Collected ThruGtpUlEnbS1FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbX
2FW
Kbps Throughput of forwarded packets
received in the X2 downlink during
the X2 handover.
Y SI 20 s. float - ThruGtpDlE
nbX2FWTot/
ThruGtpDlE
nbX2FWCnt
sum
(ThruGtpDlEnbX2
FWTot)/sum
(ThruGtpDlEnbX2
FWCnt)
ThruGtpDlEnbX
2FWTot
Kbps The sum of collected
ThruGtpDlEnbX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbX
2FWCnt
count Collected ThruGtpDlEnbX2FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpUlEnbX
2FW
Kbps Throughput of packets forwarded to
the X2 uplink during the X2
handover.
Y SI 20 s. float - ThruGtpUlE
nbX2FWTot/
ThruGtpUlE
nbX2FWCnt
sum
(ThruGtpUlEnbX2
FWTot)/sum
(ThruGtpUlEnbX2
FWCnt)
ThruGtpUlEnbX
2FWTot
Kbps The sum of collected
ThruGtpUlEnbX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbX
2FWCnt
count Collected ThruGtpUlEnbX2FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atUtraS1FW
Kbps Throughput of forwarded packets
received in the S1 downlink during
the inter-RAT (UTRAN) handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatUtraS
1FWTot/Thr
uGtpDlEnbI
RatUtraS1F
WCnt
sum
(ThruGtpDlEnbIRa
tUtraS1FWTot)/
sum
(ThruGtpDlEnbIRa
tUtraS1FWCnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 225 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpDlEnbIR
atUtraS1FWTot
Kbps The sum of collected
ThruGtpDlEnbIRatUtraS1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbIR
atUtraS1FWCnt
count Collected
ThruGtpDlEnbIRatUtraS1FW count
- SI 20 s int 0~2147483647 - -
ThruGtpUlEnbIR
atUtraS1FW
Kbps Throughput of packets forwarded to
the S1 uplink during the inter-RAT
(UTRAN) handover.
Y SI 20 s. float - ThruGtpUlE
nbIRatUtraS
1FWTot/Thr
uGtpUlEnbI
RatUtraS1F
WCnt
sum
(ThruGtpUlEnbIRa
tUtraS1FWTot)/
sum
(ThruGtpUlEnbIRa
tUtraS1FWCnt)
ThruGtpUlEnbIR
atUtraS1FWTot
Kbps The sum of collected
ThruGtpUlEnbIRatUtraS1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atUtraS1FWCnt
count Collected
ThruGtpUlEnbIRatUtraS1FW count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atUtraX2FW
Kbps Throughput of forwarded packets
received in the X2 downlink during
the inter-RAT (UTRAN) handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatUtraX
2FWTot/Thr
uGtpDlEnbI
RatUtraX2F
WCnt
sum
(ThruGtpDlEnbIRa
tUtraX2FWTot)/
sum
(ThruGtpDlEnbIRa
tUtraX2FWCnt)
ThruGtpDlEnbIR
atUtraX2FWTot
Kbps The sum of collected
ThruGtpDlEnbIRatUtraX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbIR
atUtraX2FWCnt
count Collected
ThruGtpDlEnbIRatUtraX2FW count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 226 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbIR
atUtraX2FW
Kbps Throughput of packets forwarded to
the X2 uplink during the inter-RAT
(UTRAN) handover.
Y SI 20 s. float - ThruGtpUlE
nbIRatUtraX
2FWTot/Thr
uGtpUlEnbI
RatUtraX2F
WCnt
sum
(ThruGtpUlEnbIRa
tUtraX2FWTot)/
sum
(ThruGtpUlEnbIRa
tUtraX2FWCnt)
ThruGtpUlEnbIR
atUtraX2FWTot
Kbps The sum of collected
ThruGtpUlEnbIRatUtraX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atUtraX2FWCnt
count Collected
ThruGtpUlEnbIRatUtraX2FW count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atGeranS1FW
Kbps Bytes of forwarded packets
received in the S1 downlink during
the inter-RAT (GERAN) handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatGera
nS1FWTot/
ThruGtpDlE
nbIRatGera
nS1FWCnt
sum
(ThruGtpDlEnbIRa
tGeranS1FWTot)/
sum
(ThruGtpDlEnbIRa
tGeranS1FWCnt)
ThruGtpDlEnbIR
atGeranS1FWT
ot
Kbps The sum of collected
ThruGtpDlEnbIRatGeranS1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbIR
atGeranS1FWC
nt
count Collected
ThruGtpDlEnbIRatGeranS1FW
count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 227 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbIR
atGeranS1FW
Kbps Throughput of packets forwarded to
the S1 uplink during the inter-RAT
(GERAN) handover.
Y SI 20 s. float ThruGtpUlE
nbIRatGera
nS1FWTot/
ThruGtpUlE
nbIRatGera
nS1FWCnt
sum
(ThruGtpUlEnbIRa
tGeranS1FWTot)/
sum
(ThruGtpUlEnbIRa
tGeranS1FWCnt)
ThruGtpUlEnbIR
atGeranS1FWT
ot
Kbps The sum of collected
ThruGtpUlEnbIRatGeranS1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atGeranS1FWC
nt
count Collected
ThruGtpUlEnbIRatGeranS1FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atGeranX2FW
Kbps Throughput of forwarded packets
received in the X2 downlink during
the inter-RAT (GERAN) handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatGera
nX2FWTot/
ThruGtpDlE
nbIRatGera
nX2FWCnt
sum
(ThruGtpDlEnbIRa
tGeranX2FWTot)/
sum
(ThruGtpDlEnbIRa
tGeranX2FWCnt)
ThruGtpDlEnbIR
atGeranX2FWT
ot
Kbps The sum of collected
ThruGtpDlEnbIRatGeranX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbIR
atGeranX2FWC
nt
count Collected
ThruGtpDlEnbIRatGeranX2FW
count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 228 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbIR
atGeranX2FW
Kbps Throughput of packets forwarded to
the X2 uplink during the inter-RAT
(GERAN) handover.
Y SI 20 s. float 0~3.4*10^38 ThruGtpUlE
nbIRatGera
nX2FWTot/
ThruGtpUlE
nbIRatGera
nX2FWCnt
sum
(ThruGtpUlEnbIRa
tGeranX2FWTot)/
sum
(ThruGtpUlEnbIRa
tGeranX2FWCnt)
ThruGtpUlEnbIR
atGeranX2FWT
ot
Kbps The sum of collected
ThruGtpUlEnbIRatGeranX2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atGeranX2FWC
nt
count Collected
ThruGtpUlEnbIRatGeranX2FW
count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atCdma2000Hrp
dS1FW
Kbps Throughput of forwarded packets
received in the S1 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatCdm
a2000Hrpd
S1FWTot/T
hruGtpDlEn
bIRatCdma
2000HrpdS
1FWCnt
sum
(ThruGtpDlEnbIRa
tCdma2000HrpdS
1FWTot)/sum
(ThruGtpDlEnbIRa
tCdma2000HrpdS
1FWCnt)
ThruGtpDlEnbIR
atCdma2000Hrp
dS1FWTot
Kbps The sum of collected
ThruGtpDlEnbIRatCdma2000Hrpd
S1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpDlEnbIR
atCdma2000Hrp
dS1FWCnt
count Collected
ThruGtpDlEnbIRatCdma2000Hrpd
S1FW count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 229 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpUlEnbIR
atCdma2000Hrp
dS1FW
Kbps Throughput of packets forwarded to
the S1 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y SI 20 s. float - ThruGtpUlE
nbIRatCdm
a2000Hrpd
S1FWTot/T
hruGtpUlEn
bIRatCdma
2000HrpdS
1FWCnt
sum
(ThruGtpUlEnbIRa
tCdma2000HrpdS
1FWTot)/sum
(ThruGtpUlEnbIRa
tCdma2000HrpdS
1FWCnt)
ThruGtpUlEnbIR
atCdma2000Hrp
dS1FWTot
Kbps The sum of collected
ThruGtpUlEnbIRatCdma2000Hrpd
S1FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atCdma2000Hrp
dS1FWCnt
count Collected
ThruGtpUlEnbIRatCdma2000Hrpd
S1FW count
- SI 20 s int 0~2147483647 - -
ThruGtpDlEnbIR
atCdma2000Hrp
dX2FW
Kbps Throughput of forwarded packets
received in the X2 downlink during
the inter-RAT (CDMA2000 HRPD)
handover.
Y SI 20 s. float - ThruGtpDlE
nbIRatCdm
a2000Hrpd
X2FWTot/T
hruGtpDlEn
bIRatCdma
2000HrpdX
2FWCnt
sum
(ThruGtpDlEnbIRa
tCdma2000HrpdX
2FWTot)/sum
(ThruGtpDlEnbIRa
tCdma2000HrpdX
2FWCnt)
ThruGtpDlEnbIR
atCdma2000Hrp
dX2FWTot
Kbps The sum of collected
ThruGtpDlEnbIRatCdma2000Hrpd
X2FW
- SI 20 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 230 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ThruGtpDlEnbIR
atCdma2000Hrp
dX2FWCnt
count Collected
ThruGtpDlEnbIRatCdma2000Hrpd
X2FW count
SI 20 s int 0~2147483647 - -
ThruGtpUlEnbIR
atCdma2000Hrp
dX2FW
Kbps Throughput of packets forwarded to
the X2 uplink during the inter-RAT
(CDMA2000 HRPD) handover.
Y SI 20 s. float - ThruGtpUlE
nbIRatCdm
a2000Hrpd
X2FWTot/T
hruGtpUlEn
bIRatCdma
2000HrpdX
2FWCnt
sum
(ThruGtpUlEnbIRa
tCdma2000HrpdX
2FWTot)/sum
(ThruGtpUlEnbIRa
tCdma2000HrpdX
2FWCnt)
ThruGtpUlEnbIR
atCdma2000Hrp
dX2FWTot
Kbps The sum of collected
ThruGtpUlEnbIRatCdma2000Hrpd
X2FW
- SI 20 s float 0~3.4*10^38 - -
ThruGtpUlEnbIR
atCdma2000Hrp
dX2FWCnt
count Collected
ThruGtpUlEnbIRatCdma2000Hrpd
X2FW count
- SI 20 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 231 of 427
2600-00FET7GAT 6.0
10 SRB Signalling Radio Bearer (SRB, data Plane of PDCP) statistics provide the Control Plane PDCP SDU bit rates per cell over the downlin
k and uplink respectively.
10.1 Cell PDCP SDU bit-rate
The eNB groups the Control Plane PDCP SDU bit rates per cell by the downlink/uplink in accordance with the 3GPP standard (TS32.
425 Performance Measurements) and calculates the average value at every measurement interval.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
PdcpSduBitrat
eDl
Kbps Average cell bit-rate of the
control plane PDCP SDUs
over the downlink.
Y SI 2 s. float 0-3.4*10^38 PdcpSduBitrateDlTot/
PdcpSduBitrateDlCnt
sum
(PdcpSduBitrateDlTot)/
sum
(PdcpSduBitrateDlCnt)
PdcpSduBitrat
eDlTot
Kbps The sum of collected
PdcpSduBitrateDl
- SI 2 s float 0~3.4*10^38 - -
PdcpSduBitrat
eDlCnt
count Collected PdcpSduBitrateDl
count
- SI 2 s int 0~21474836
47
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 232 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
PdcpSduBitrat
eUl
Kbps Average cell bit-rate of the
control plane PDCP SDUs
over the uplink.
Y SI 2 s. float 0-3.4*10^38 PdcpSduBitrateUlTot/
PdcpSduBitrateUlCnt
sum
(PdcpSduBitrateUlTot)/
sum
(PdcpSduBitrateUlCnt)
PdcpSduBitrat
eUlTot
Kbps The sum of collected
PdcpSduBitrateUl
- SI 2 s float 0~3.4*10^38 - -
PdcpSduBitrat
eUlCnt
count Collected PdcpSduBitrateUl
count
- SI 2 s int 0~21474836
47
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 233 of 427
2600-00FET7GAT 6.0
11 DRB Data Radio Bearer (DRB, User Plane of RLC/MAC) statistics provide QCI information of the DRB, such as the number of active UEs,
packet delay, packet drop rate, packet loss rate and IP latency.
11.1 Active UEs
This section provides statistics data for the average number of UEs where the buffer data of the DRB is waiting.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UEActiveDl count The number of UEs satisfying one or more
of the following conditions in a continuous
20 ms interval (sampling occasion) is
summed every 80 ms for each QCI.
- If there is a DRB which received a buffer
occupancy request from the RLC
- If there is a DRB which received an HARQ
retransmission request When a collection
interval ends, the average is calculated by
Y SI 5.12 s. float 0-3.4*10^38 UEActiveDlTot/
UEActiveDlCnt
sum
(UEActiveDlTot)/
sum
(UEActiveDlCnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 234 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
dividing the summed number of UEs by
the number of sampling occasions that
occurred.
UEActiveDl
Tot
count Sum of UEActiveDl collected Y SI 5.12 s. float 0-3.4*10^38 - -
UEActiveDl
Cnt
count Collected UEActiveDl count - SI 5.12 s int 0~2147483
647
- -
UEActiveUl count The number of UEs satisfying one or more
of the following conditions in a continuous
20 ms interval is summed every 80 ms for
each QCI.
- If there is a DRB where the uplink data
requested to be allocated using the Buffer
Status Report message is waiting
- If there is a DRB which received an HARQ
retransmission request When a collection
interval ends, the average is calculated by
dividing the summed number of UEs by
the number of sampling occasions that
occurred.
Y SI 5.12 s. float 0-3.4*10^38 UEActiveUlTot/
UEActiveUlCnt
sum
(UEActiveUlTot)/
sum
(UEActiveUlCnt)
UEActiveUl
Tot
count Sum of UEActiveUl collected Y SI 5.12 s. float 0-3.4*10^38 - -
UEActiveUl
Cnt
count Collected UEActiveUl count - SI 5.12 s int 0~2147483
647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 235 of 427
2600-00FET7GAT 6.0
11.2 Packet Delay
This section provides statistics data for the DL PDCP SDU delay defined in the standard 3GPP TS 36.314 for each QCI.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpSduDelay ms Average DL PDCP SDU
delay DL PDCP SDU delay
on the downlink that
occurred for 1 minute.
Y SI 10 s. float 0-60*Period*1000 PdcpSduDelayTot/
PdcpSduDelayCnt
sum
(PdcpSduDelayTot)/
sum
(PdcpSduDelayCnt)
PdcpSduDelay
Tot
ms Sum of PdcpSduDelay
collected
Y SI 10 s. float 0-3.4*10^38 - -
PdcpSduDelay
Cnt
count Collected PdcpSduDelay
count
- SI 10 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 236 of 427
2600-00FET7GAT 6.0
11.3 Packet Drop Rate
Statistics provides per-eNB drop rate for downlink packet drops of the user plane traffic per QCI in accordance with the 3GPP standar
d (TS32.425 Performance Measurements. Packet drops can occur due to traffic congestion and are calculated (in ppm) by multiplying it
by 1E6 according to the standard (TS 36.314 Layer 2-Measurements).
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpSduDropRateDl ppm DL PDCP SDU packet drop rate on
the downlink that occurred for one
minute
Y SI 1 min. float 0-
3.4*10^38
PdcpSduDr
opRateDlTot
/PdcpSduDr
opRateDlCn
t
sum
(PdcpSduDropRat
eDlTot)/sum
(PdcpSduDropRat
eDlCnt)
PdcpSduDropRateDl
Tot
ppm The sum of collected
PdcpSduDropRateDl
- SI 1 min float 0~3.4*10^
38
- -
PdcpSduDropRateDl
Cnt
count Collected PdcpSduDropRateDl
count
- SI 1 min int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 237 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpPduDropRateDl ppm Average DL PDCP SDU drop rate
DL PDCP SDU drop rate on the
downlink that occurred for 1
minute.
- SI 10 s. float 0-
3.4*10^38
PdcpPduDr
opRateDlTot
/PdcpPduDr
opRateDlCn
t
sum
(PdcpPduDropRat
eDlTot)/
sum
(PdcpPduDropRat
eDlCnt)
PdcpPduDropRateDl
Tot
ppm The sum of collected
PdcpPduDropRateDl
- SI 10 s float 0~3.4*10^
38
- -
PdcpPduDropRateDl
Cnt
count Collected PdcpPduDropRateDl
count
- SI 10 s int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 238 of 427
2600-00FET7GAT 6.0
11.4 Packet Loss Rate (ppm)
Statistics provides per-eNB loss rate for PDCP SDUs of the user plane traffic that have not been received successfully over the uplink
per QCI in accordance with the 3GPP standard (TS32.425 Performance Measurements).
The rate is calculated (in ppm) by multiplying 1E6 according to the standard (TS 36.314 Layer 2-Measurements).
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
PdcpSduLossR
ateUl
ppm UL PDCP SDU packet loss
rate on the uplink that
occurred for 1 minute
Y SI 1 min. float 0-3.4*10^38 PdcpSduLo
ssRateUlTot
/PdcpSduLo
ssRateUlCn
t
sum (PdcpSduLossRateUlTot)/
sum (PdcpSduLossRateUlCnt)
PdcpSduLossR
ateUlTot
ppm The sum of collected
PdcpSduLossRateUl
- SI 1 min float 0~3.4*10^38 - -
PdcpSduLossR
ateUlCnt
count Collected
PdcpSduLossRateUl count
- SI 1 min int 0~21474836
47
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 239 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
PdcpSduAirIntf ppm Average DL PDCP SDU
loss rate DL PDCP SDU
packet loss rate on the
downlink that occurred for
10 seconds.
Y SI 10 s. float 0-3.4*10^38 PdcpSduAir
IntfTot/Pdcp
SduAirIntfC
nt
sum (PdcpSduAirIntfTot)/sum
(PdcpSduAirIntfCnt)
PdcpSduAirIntf
Tot
ppm The sum of collected
PdcpSduAirIntf
- SI 10 s float 0~3.4*10^38 - -
PdcpSduAirIntf
Cnt
count Collected PdcpSduAirIntf
count
- SI 10 s int 0~21474836
47
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 240 of 427
2600-00FET7GAT 6.0
11.5 IP Latency measurements
This section provides statistics data for the DL IP latency defined in the standard 3GPP TS 32.450 for each QCI.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
IpLateDl ms IP latency in the downlink, SAE
bearer level
IP latency for 10 seconds in the
downlink.
Y SI 10 s. float 0-60*Period*1000 IpLateDlTot/
IpLateDlCnt
sum (IpLateDlTot)/
sum (IpLateDlCnt)
IpLateDlTot ms The sum of collected IpLateDl - SI 10 s float 0~3.4*10^38 - -
IpLateDlCnt count Collected IpLateDl count - SI 10 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 241 of 427
2600-00FET7GAT 6.0
12 RRU The Radio Resource Utilization (RRU) statistics include DL/UL PRB Usage, DL/UL Total PRB Usage, and Cell Unavailable Time stati
stics.
These statistics items are described in the following table.
12.1 DL/UL PRB Usage
This section provides rate of PRB allocated to the DTCH among the total PRB on the DL/UL.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PrbDl % The PRB usage used as the
downlink DTCH traffic
Y SI 5.12 s. float 0-100 PrbDlTot/PrbD
lCnt
sum (PrbDlTot)/sum
(PrbDlCnt)
PrbDlTot % The sum of collected PrbDl - SI 5.12 s float 0~3.4*10^38 - -
PrbDlCnt count Collected PrbDl count - SI 5.12 s int 0~2147483647 - -
PrbUl % The PRB usage used as the
uplink DTCH traffic
- SI 5.12 s. float 0-100 PrbUlTot/PrbU
lCnt
sum (PrbUlTot)/sum
(PrbUlCnt)
PrbUlTot % The sum of collected PrbUl - SI 5.12 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 242 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PrbUlCnt count Collected PrbUl count - SI 5.12 s int 0~2147483647 - -
PrbDlCu
rrent
% DL PRB Current Usage for
traffic
- SI 5.12 s float 0~3.4*10^38 - -
PrbUlCu
rrent
% UL PRB Current Usage for
traffic
- SI 5.12 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 243 of 427
2600-00FET7GAT 6.0
12.2 DL/UL Total PRB Usage
This section provides statistics data for usage rate (percentage) of the PRB on the downlink PDSCH and the uplink PUSCH among th
e total PRB.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
TotPrbDl % The resource used for the PDSCH/
PDCCH transmission among the
total downlink resource
Y GAUGE 5.12 s. float 0-100 TotPrbDlTot/
TotPrbDlCnt
sum (TotPrbDlTot)/sum
(TotPrbDlCnt)
TotPrbDlMin % Minimum value of resources used
for the PDSCH/PDCCH
transmission among the total
downlink resources
- GAUGE 5.12 s float 0~100 - min (TotPrbDlMin)
TotPrbDlMax % Maximum value of resources used
for the PDSCH/PDCCH
transmission among the total
downlink resources
- GAUGE 5.12 s float 0~100 - max (TotPrbDlMax)
TotPrbDlTot % The sum of collected TotPrbDl - GAUGE 5.12 s float 0~3.4*10
^38
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 244 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
TotPrbDlCnt count Collected TotPrbDl count - GAUGE 5.12 s int 0~21474
83647
- -
TotGbrPrbDl % Ratio of the resource used to
transmit the GBR traffic against the
total downlink resources.
Y GAUGE 5.12 s. float 0-100 TotGbrPrbDl
Tot/TotGbrPr
bDlCnt
sum (TotGbrPrbDlTot)/
sum (TotGbrPrbDlCnt)
TotGbrPrbDl
Min
% Minimum value of resources used
for the GBR traffic transmission
among the total downlink resources
- GAUGE 5.12 s float 0~100 - min (TotGbrPrbDlMin)
TotGbrPrbDl
Max
% Maximum value of resources used
for the GBR traffic transmission
among the total downlink resources
- GAUGE 5.12 s float 0~100 - max (TotGbrPrbDlMax)
TotGbrPrbDlT
ot
% The sum of collected TotGbrPrbDl - GAUGE 5.12 s float 0~3.4*10
^38
- -
TotGbrPrbDlC
nt
count Collected TotGbrPrbDl count - GAUGE 5.12 s int 0~21474
83647
- -
TotNGbrPrbDl % Ratio of the resource used to
transmit the non-GBR traffic against
the total downlink resources.
Y GAUGE 5.12 s. float 0-100 TotNGbrPrb
DlTot/TotNG
brPrbDlCnt
sum (TotNGbrPrbDlTot)/
sum (TotNGbrPrbDlCnt)
TotNGbrPrbDl
Min
% Minimum value of resources used
for the non-GBR traffic transmission
among the total downlink resources
- GAUGE 5.12 s float 0~100 - min (TotNGbrPrbDlMin)
TotNGbrPrbDl
Max
% Maximum value of resources used
for the non-GBR traffic transmission
among the total downlink resources
- GAUGE 5.12 s float 0~100 - max (TotNGbrPrbDlMax)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 245 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
TotNGbrPrbDl
Tot
% The sum of collected TotNGbrPrbDl - GAUGE 5.12 s float 0~3.4*10
^38
- -
TotNGbrPrbDl
Cnt
count Collected TotNGbrPrbDl count - GAUGE 5.12 s int 0~21474
83647
- -
TotPrbUl % The resource used for the PUSCH
transmission among the total uplink
resource
Y GAUGE 5.12 s. float 0-100 TotPrbUlTot/
TotPrbUlCnt
sum (TotPrbUlTot)/sum
(TotPrbUlCnt)
TotPrbUlMin % Minimum value of resources used
for the PUSCH transmission among
the total uplink resources
- GAUGE 5.12 s float 0~100 - min (TotPrbUlMin)
TotPrbUlMax % Maximum value of resources used
for the PUSCH transmission among
the total uplink resources
- GAUGE 5.12 s float 0~100 - max (TotPrbUlMax)
TotPrbUlTot % The sum of collected TotPrbUl - GAUGE 5.12 s float 0~3.4*10
^38
- -
TotPrbUlCnt count Collected TotPrbUl count - GAUGE 5.12 s int 0~21474
83647
- -
TotGbrPrbUl % Ratio of the resource used to
transmit the GBR traffic against the
total uplink resources.
Y GAUGE 5.12 s. float 0-100 TotGbrPrbUl
Tot/TotGbrPr
bUlCnt
sum (TotGbrPrbUlTot)/
sum (TotGbrPrbUlCnt)
TotGbrPrbUl
Min
% Minimum value of resources used
for the GBR traffic transmission
among the total uplink resources
- GAUGE 5.12 s float 0~100 - min (TotGbrPrbUlMin)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 246 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
TotGbrPrbUl
Max
% Maximum value of resources used
for the GBR traffic transmission
among the total uplink resources
- GAUGE 5.12 s float 0~100 - max (TotGbrPrbUlMax)
TotGbrPrbUlT
ot
% The sum of collected TotGbrPrbUl - GAUGE 5.12 s float 0~3.4*10
^38
- -
TotGbrPrbUlC
nt
count Collected TotGbrPrbUl count - GAUGE 5.12 s int 0~21474
83647
- -
TotNGbrPrbUl % Ratio of the resource used to
transmit the non-GBR traffic against
the total uplink resources.
Y GAUGE 5.12 s. float 0-100 TotNGbrPrb
UlTot/TotNG
brPrbUlCnt
sum (TotNGbrPrbUlTot)/
sum (TotNGbrPrbUlCnt)
TotNGbrPrbUl
Min
% Minimum value of resources used
for the non-GBR traffic transmission
among the total uplink resources
- GAUGE 5.12 s float 0~100 - min (TotNGbrPrbUlMin)
TotNGbrPrbUl
Max
% Maximum value of resources used
for the non-GBR traffic transmission
among the total uplink resources
- GAUGE 5.12 s float 0~100 - max (TotNGbrPrbUlMax)
TotNGbrPrbUl
Tot
% The sum of collected TotNGbrPrbUl - GAUGE 5.12 s float 0~3.4*10
^38
- -
TotNGbrPrbUl
Cnt
count Collected TotNGbrPrbUl count - GAUGE 5.12 s int 0~21474
83647
- -
TotPrbDlCurr
ent
% DL Total Current PRB Usage - GAUGE 5.12 float 0~100 - -
TotPrbUlCurr
ent
% UL Total Current PRB Usage - GAUGE 5.12 s float 0~100 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 247 of 427
2600-00FET7GAT 6.0
12.3 Cell Unavailable Time
This section provides statistics data for the average locked time and disabled time per unit time.
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CellUnavailableTimeLock s Measures the lock time per
measurement period.
Y CC 1 min. int 0-60*Period - -
CellUnavailableTimeDown s Measures the disabled time
per measurement period.
Y CC 1 min. int 0-60*Period - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 248 of 427
2600-00FET7GAT 6.0
13 S1SIG S1 Application Protocol Signalling (S1SIG) provides information about UE-associated logical S1-connection establishment statistics.
These statistics items are described in the following table.
13.1 UE-associated logical S1-connection establishment
This section provides statistics data for S1 Logical Connection Setup for each cell. When the Initial UE message is transmitted, it is c
ounted as Attempt; when the Initial Context Setup Request message is received, it is counted as Success. A failure is counted when a
failure or timeout occurs during the procedure and the applicable cause is recorded.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 249 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1ConnEstabA
tt
count UE logical S1 connection setup
attempt count
Y CC event int 0-2147483647 - -
S1ConnEstabS
ucc
count UE Logical S1 Connection Setup
success count.
Y CC event int 0-2147483647 - -
S1ConnEstabF
ail_CP_CC_FA
IL
count A call is released due to reset
notification (eNB failure or block
restart) from ECMB or by the ECCB
block during S1 connection.
Y CC event int 0-2147483647 - -
S1ConnEstabF
ail_S1AP_CU_
FAIL
count A call is released due to the S1AP
specification cause during S1
connection.
Y CC event int 0-2147483647 - -
S1ConnEstabF
ail_S1AP_LINK
_FAIL
count A call is released due to S1 SCTP link
failure during S1 connection.
Y CC event int 0-2147483647 - -
S1ConnEstabF
ail_S1AP_SIG
_FAIL
count A call is released due to receiving
S1AP signaling during S1 connection.
Y CC event int 0-2147483647 - -
S1ConnEstabF
ail_S1AP_SIG
_TO
count A call is released due to S1AP
signaling timeout (not received) during
S1 connection.
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 250 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 32. Collection Time for UE-associated Logical S1-Connection Establishment
eNB UE MME S/GW
RRC_IDLE
RRC_CONNECTED
Initial UE Message 1 Attempt
2 Success Initial Context Setup Request
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 251 of 427
2600-00FET7GAT 6.0
13.2 S1 Connection Time
This section provides statistics on S1 setup time.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
EstabCause 0~5 RRC Connection Establishment Cause
0: emergency: Emergency call connection
1: highPriorityAccess: Access by the UE with a specific access class
2: mt_Access: Access by the UE due to paging received
3: mo_Signaling: Access by the UE due to attach
4: mo_Data: Access by the UE due to service request
5: relocated: Access by the UE due to handover
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1SigTime_
Avg
ms S1 connection average setup
time
Y GAUGE event float 0-3.4*10^38 S1SigTime_Tot/
S1SigTime_Cnt
sum (S1SigTime_Tot)/
sum (S1SigTime_Cnt)
S1SigTime_
Max
ms Maximum setup time for S1
connection
Y GAUGE event float 0-3.4*10^38 - max (S1SigTime_Max)
S1SigTime_
Tot
ms Accumulated setup time for S1
connection
Y GAUGE event float 0-3.4*10^38 - -
S1SigTime_
Cnt
count The number of S1SigTime_Avg
called
Y GAUGE event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 252 of 427
2600-00FET7GAT 6.0
14 PAG PAG is paging statistics on the number of paging attempts by the RRC and number of paging messages that are discarded when the R
LC cannot process paging messages upon receipt due to insufficient capacity.
The RLC can save up to 1,024 paging messages in each cell.
14.1 Paging Performance
It collects statistics data for paging. The eNB collects the statistics data for the paging attempt for each cell of the base station made
by the MME’s paging request. Also, it collects the number of the discarded paging messages that were not processed by the eNB for
each cell.
The paging for both of system information update and ETWA indication is not included. The eNB, which is an access network, does n
ot collect the statistics data for the paging responses which are made through NAS signaling.
Index
Name Range Description
cNum 0~2 Index of the cell to which RRC paging will be transmitted.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DiscardedNbr count Paging record count discarded in the eNB Y CC 10 s. int 0-2147483647 - -
AttPaging count Paging transmission attempt count Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 253 of 427
2600-00FET7GAT 6.0
Collection Time
Figure 33. Collection Time for Paging Performance
eNB UE MME S/GW
RRC_IDLE
Paging
1 Attempt
Paging Request
Paging
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 254 of 427
2600-00FET7GAT 6.0
15 Power
15.1 Power
This section provides statistics data for average interference over thermal noise for each PRB, the average thermal noise for each cell,
the average RSSI for each cell, and the average RSSI for each antenna.
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
InterferencePo
wer
dBm Average interference over
thermal noise for each
PRB
Y SI 5.12 s. float -1000-1000 InterferencePowerTot/
InterferencePowerCnt
sum
(InterferencePowerTot)/
sum
(InterferencePowerCnt)
InterferencePo
werTot
dBm The sum of collected
InterferencePower
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- -
InterferencePo
werCnt
count Collected
InterferencePower count
- SI 5.12 s int 0~2147483
647
- -
ThermalNoise
Power
dBm Average Thermal Noise Y SI 5.12 s. float -1000-1000 ThermalNoisePowerTo
t/ThermalNoisePower
Cnt
sum
(ThermalNoisePowerTot)/
sum
(ThermalNoisePowerCnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 255 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
ThermalNoise
PowerTot
dBm The sum of collected
ThermalNoisePower
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- -
ThermalNoise
PowerCnt
count Collected
ThermalNoisePower count
- SI 5.12 s int 0~2147483
647
- -
RssiOverPath dBm Average RSSI for each
antenna
Y SI 5.12 s. float -1000-1000 RssiOverPathTot/Rssi
OverPathCnt
sum (RssiOverPathTot)/
sum (RssiOverPathCnt)
RssiOverPathT
ot
dBm The sum of collected
RssiOverPath
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- -
RssiOverPath
Cnt
count Collected RssiOverPath
count
- SI 5.12 s int 0~2147483
647
- -
RssiPath0 dBm Average RSSI of Antenna
#0
Y SI 5.12 s. float -1000-1000 RssiPath0Tot/RssiPath
0Cnt
sum (RssiPath0Tot)/sum
(RssiPath0Cnt)
RssiPath0Tot dBm The sum of collected
RssiPath0
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- -
RssiPath0Cnt count Collected RssiPath0 count - SI 5.12 s int 0~2147483
647
- -
RssiPath1 dBm Average RSSI of Antenna
#1
Y SI 5.12 s. float -1000-1000 RssiPath1Tot/RssiPath
1Cnt
sum (RssiPath1Tot)/sum
(RssiPath1Cnt)
RssiPath1Tot dBm The sum of collected
RssiPath1
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- -
RssiPath1Cnt count Collected RssiPath1 count - SI 5.12 s int 0~2147483
647
- -
RssiPath0_Cur
rent
dBm The most recently
collected RssiPath0
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- max (RssiPath0_Current)
RssiPath1_Cur
rent
dBm The most recently
collected RssiPath1
- SI 5.12 s float -3.4*10^38
~3.4*10^38
- max (RssiPath1_Current)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 256 of 427
2600-00FET7GAT 6.0
15.2 RNTP of own cell
This section provides statistics data for Relative Narrowband TX Power (RNTP) value for each PRB.
RNTP is defined as follows, and it has the value 0 or 1.
RNTP (PRB #k) = 0, if PRB #k; the maximum Tx power guarantees the level below the given threshold.
RNTP (PRB #k) = 1, if PRB #k; the maximum Tx power does not guarantee the level below the given threshold
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB0 indicator RNTP of downlink PRB #0. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB1 indicator RNTP of downlink PRB #1. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB2 indicator RNTP of downlink PRB #2. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB3 indicator RNTP of downlink PRB #3. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB4 indicator RNTP of downlink PRB #4. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB5 indicator RNTP of downlink PRB #5. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB6 indicator RNTP of downlink PRB #6. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB7 indicator RNTP of downlink PRB #7. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB8 indicator RNTP of downlink PRB #8. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB9 indicator RNTP of downlink PRB #9. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 257 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB10 indicator RNTP of downlink PRB #10. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB11 indicator RNTP of downlink PRB #11. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB12 indicator RNTP of downlink PRB #12. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB13 indicator RNTP of downlink PRB #13. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB14 indicator RNTP of downlink PRB #14. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB15 indicator RNTP of downlink PRB #15. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB16 indicator RNTP of downlink PRB #16. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB17 indicator RNTP of downlink PRB #17. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB18 indicator RNTP of downlink PRB #18. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB19 indicator RNTP of downlink PRB #19. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB20 indicator RNTP of downlink PRB #20. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB21 indicator RNTP of downlink PRB #21. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB22 indicator RNTP of downlink PRB #22. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB23 indicator RNTP of downlink PRB #23. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB24 indicator RNTP of downlink PRB #24. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB25 indicator RNTP of downlink PRB #25. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB26 indicator RNTP of downlink PRB #26. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB27 indicator RNTP of downlink PRB #27. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB28 indicator RNTP of downlink PRB #28. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB29 indicator RNTP of downlink PRB #29. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB30 indicator RNTP of downlink PRB #30. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB31 indicator RNTP of downlink PRB #31. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 258 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB32 indicator RNTP of downlink PRB #32. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB33 indicator RNTP of downlink PRB #33. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB34 indicator RNTP of downlink PRB #34. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB35 indicator RNTP of downlink PRB #35. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB36 indicator RNTP of downlink PRB #36. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB37 indicator RNTP of downlink PRB #37. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB38 indicator RNTP of downlink PRB #38. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB39 indicator RNTP of downlink PRB #39. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB40 indicator RNTP of downlink PRB #40. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB41 indicator RNTP of downlink PRB #41. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB42 indicator RNTP of downlink PRB #42. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB43 indicator RNTP of downlink PRB #43. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB44 indicator RNTP of downlink PRB #44. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB45 indicator RNTP of downlink PRB #45. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB46 indicator RNTP of downlink PRB #46. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB47 indicator RNTP of downlink PRB #47. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB48 indicator RNTP of downlink PRB #48. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB49 indicator RNTP of downlink PRB #49. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB50 indicator RNTP of downlink PRB #50. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB51 indicator RNTP of downlink PRB #51. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB52 indicator RNTP of downlink PRB #52. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB53 indicator RNTP of downlink PRB #53. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 259 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB54 indicator RNTP of downlink PRB #54. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB55 indicator RNTP of downlink PRB #55. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB56 indicator RNTP of downlink PRB #56. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB57 indicator RNTP of downlink PRB #57. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB58 indicator RNTP of downlink PRB #58. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB59 indicator RNTP of downlink PRB #59. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB60 indicator RNTP of downlink PRB #60. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB61 indicator RNTP of downlink PRB #61. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB62 indicator RNTP of downlink PRB #62. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB63 indicator RNTP of downlink PRB #63. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB64 indicator RNTP of downlink PRB #64. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB65 indicator RNTP of downlink PRB #65. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB66 indicator RNTP of downlink PRB #66. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB67 indicator RNTP of downlink PRB #67. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB68 indicator RNTP of downlink PRB #68. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB69 indicator RNTP of downlink PRB #69. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB70 indicator RNTP of downlink PRB #70. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB71 indicator RNTP of downlink PRB #71. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB72 indicator RNTP of downlink PRB #72. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB73 indicator RNTP of downlink PRB #73. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB74 indicator RNTP of downlink PRB #74. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB75 indicator RNTP of downlink PRB #75. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 260 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB76 indicator RNTP of downlink PRB #76. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB77 indicator RNTP of downlink PRB #77. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB78 indicator RNTP of downlink PRB #78. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB79 indicator RNTP of downlink PRB #79. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB80 indicator RNTP of downlink PRB #80. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB81 indicator RNTP of downlink PRB #81. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB82 indicator RNTP of downlink PRB #82. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB83 indicator RNTP of downlink PRB #83. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB84 indicator RNTP of downlink PRB #84. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB85 indicator RNTP of downlink PRB #85. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB86 indicator RNTP of downlink PRB #86. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB87 indicator RNTP of downlink PRB #87. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB88 indicator RNTP of downlink PRB #88. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB89 indicator RNTP of downlink PRB #89. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB90 indicator RNTP of downlink PRB #90. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB91 indicator RNTP of downlink PRB #91. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB92 indicator RNTP of downlink PRB #92. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB93 indicator RNTP of downlink PRB #93. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB94 indicator RNTP of downlink PRB #94. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB95 indicator RNTP of downlink PRB #95. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB96 indicator RNTP of downlink PRB #96. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB97 indicator RNTP of downlink PRB #97. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 261 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type
Min/
Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RntpOwnCell_PRB98 indicator RNTP of downlink PRB #98. Y CC 5.12 s. int 0-1 - -
RntpOwnCell_PRB99 indicator RNTP of downlink PRB #99. Y CC 5.12 s. int 0-1 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 262 of 427
2600-00FET7GAT 6.0
15.3 RRH_RSSI
Collects the statistics data for the Received Signal Strength Indicator (RSSI) values for each RRH path.
Index
Name Range Description
BID 0~0 Board ID
RuPort 0~2 Ru Port Number
Cascade 0~0 Cascade ID
RSSIPath 0~7 RSSI Path ID
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RrhRssiAvg dBm The average values of RSSI for
each RRH path
Y GAUGE 10 s float -1000~1000 10*(log10
(RrhRssiTot/Rr
hRssiCnt)-12)
10*(log10 (sum
(RrhRssiTot)/sum
(RrhRssiCnt))-12)
RrhRssiMax dBm The maximum values of RSSI for
each RRH path
Y GAUGE 10 s float -1000~1000 - max (RrhRssiMax)
RrhRssi dBm The most recently collected RSSI
values for each RRH path
Y GAUGE 10 s float -1000~1000 - max (RrhRssi)
RrhRssiTot mW*10^12 The total sum of the RSSI linear
values for each RRH path
Y GAUGE 10 s float -3.4*10^38
~3.4*10^38
- -
RrhRssiCnt count Number of times that the RSSI
values were collected for each
RRH path
Y GAUGE 10 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 263 of 427
2600-00FET7GAT 6.0
16 RA This section provides statistics data for Random Access Preamble are provided. These statistics items are described in the following tab
le.
16.1 Random Access Preambles
It collects the number of the high-speed monitoring result and the RACH preamble.
For the High Speed Monitoring, estimates the moving speed of the terminals within the cell and counts the terminals which speed is d
etermined as high. Also, it collects the number of detected Dedicated Preambles, Contention-based Group A Preambles, and Contention-
based Group B Preambles, then collects the average per second of the detected preambles.
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
HighSpeedMonito
ring
count The number of UEs which are
monitored for moving speed
Y CC 5.12 s. int 0-2147483647 - -
NoofHighSpeed count The number of high speed UEs
which are monitored
Y CC 5.12 s. int 0-2147483647 - -
DedicatedPream
bles
count The number of detected dedicated
preambles.
Y CC 5.12 s. int 0-2147483647 - -
DedicatedPream count The number of failures to get Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 264 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
blesAssignFail dedicated preamble allocation after
requesting the dedicated preamble
from the RRC to the MAC
Randomlyselecte
dpreamblesLow
count The number of the preambles
belonging to Group A among the
detected contention based
preambles
Y CC 5.12 s. int 0-2147483647 - -
Randomlyselecte
dpreamblesHigh
count The number of the preambles
belonging to Group B among the
detected contention based
preambles
Y CC 5.12 s. int 0-2147483647 - -
RACHUsage count Average number of detected
preambles
Y SI 5.12 s. float 0-3.4*10^38 RACHUsag
eTot/RACH
UsageCnt
sum
(RACHUsageTot)/
sum
(RACHUsageCnt)
RACHUsageTot count The sum of collected RACHUsage SI 5.12 s float 0~3.4*10^38 - -
RACHUsageCnt count Collected RACHUsage count SI 5.12 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 265 of 427
2600-00FET7GAT 6.0
17 HARQ The HARQ provides the DL/UL transmission statistics. These statistics items are described in the following table.
17.1 DL/UL Transmission
This section provides statistics data for each HARQ transmission for PDSCH/PUSCH and the Block Error Rate (BLER) information.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
DlResidualBLE
R_Retrans0
% PDSCH BLER for the initial
HARQ transmission
Y OW Period float 0-100 (DlTransmission_Re
trans1/DlTransmissi
on_Retrans0)*100
(sum (DlTransmission_
Retrans1)/sum
(DlTransmission_Retra
ns0))*100
DlResidualBLE
R_Retrans1
% PDSCH BLER for the first
HARQ retransmission
Y OW Period float 0-100 (DlTransmission_Re
trans2/DlTransmissi
on_Retrans1)*100
(sum (DlTransmission_
Retrans2)/sum
(DlTransmission_Retra
ns1))*100
DlResidualBLE
R_Retrans2
% PDSCH BLER for the
second HARQ
Y OW Period float 0-100 (DlTransmission_Re
trans3/DlTransmissi
(sum (DlTransmission_
Retrans3)/sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 266 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
retransmission on_Retrans2)*100 (DlTransmission_Retra
ns2))*100
DlResidualBLE
R_Retrans3
% PDSCH BLER for the third
HARQ retransmission
Y OW Period float 0-100 (DlTransmission_Na
cked_Retrans3/DlTr
ansmission_Retrans
3)*100
(sum (DlTransmission_
Nacked_Retrans3)/
sum (DlTransmission_
Retrans3))*100
UlResidualBLE
R_Retrans0
% PUSCH BLER for the initial
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans1/UlTransmissi
on_Retrans0)*100
(sum (UlTransmission_
Retrans1)/sum
(UlTransmission_Retra
ns0))*100
UlResidualBLE
R_Retrans1
% PUSCH BLER for the first
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans2/UlTransmissi
on_Retrans1)*100
(sum (UlTransmission_
Retrans2)/sum
(UlTransmission_Retra
ns1))*100
UlResidualBLE
R_Retrans2
% PUSCH BLER for the
second HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans3/UlTransmissi
on_Retrans2)*100
(sum (UlTransmission_
Retrans3)/sum
(UlTransmission_Retra
ns2))*100
UlResidualBLE
R_Retrans3
% PUSCH BLER for the third
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Na
cked_Retrans27/UlT
ransmission_Retran
s3)*100
(sum (UlTransmission_
Nacked_Retrans27)/
sum (UlTransmission_
Retrans3))*100
UlResidualBLE
R_Retrans4
% PUSCH BLER for the fourth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans5/UlTransmissi
on_Retrans4)*100
(sum (UlTransmission_
Retrans5)/sum
(UlTransmission_Retra
ns4))*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 267 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
UlResidualBLE
R_Retrans5
% PUSCH BLER for the fifth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans6/UlTransmissi
on_Retrans5)*100
(sum (UlTransmission_
Retrans6)/sum
(UlTransmission_Retra
ns5))*100
UlResidualBLE
R_Retrans6
% PUSCH BLER for the sixth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans7/UlTransmissi
on_Retrans6)*100
(sum (UlTransmission_
Retrans7)/sum
(UlTransmission_Retra
ns6))*100
UlResidualBLE
R_Retrans7
% PUSCH BLER for the
seventh HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans8/UlTransmissi
on_Retrans7)*100
(sum (UlTransmission_
Retrans8)/sum
(UlTransmission_Retra
ns7))*100
UlResidualBLE
R_Retrans8
% PUSCH BLER for the eighth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans9/UlTransmissi
on_Retrans8)*100
(sum (UlTransmission_
Retrans9)/sum
(UlTransmission_Retra
ns8))*100
UlResidualBLE
R_Retrans9
% PUSCH BLER for the ninth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Re
trans10/UlTransmis
sion_Retrans9)*100
(sum (UlTransmission_
Retrans10)/sum
(UlTransmission_Retra
ns9))*100
UlResidualBLE
R_Retrans10
% PUSCH BLER for the tenth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans11/UlTransmissi
on_Retrans10)*100
(sum (UlTransmission_
Retrans11)/sum
(UlTransmission_Retra
ns10))*100
UlResidualBLE
R_Retrans11
% PUSCH BLER for the
eleventh HARQ
Y OW Period float 0-100 (UlTransmission_Ret
rans12/UlTransmissi
(sum (UlTransmission_
Retrans12)/sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 268 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
retransmission on_Retrans11)*100 (UlTransmission_Retra
ns11))*100
UlResidualBLE
R_Retrans12
% PUSCH BLER for the twelfth
HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans13/UlTransmissi
on_Retrans12)*100
(sum (UlTransmission_
Retrans13)/sum
(UlTransmission_Retra
ns12))*100
UlResidualBLE
R_Retrans13
% PUSCH BLER for the
thirteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans14/UlTransmissi
on_Retrans13)*100
(sum (UlTransmission_
Retrans14)/sum
(UlTransmission_Retra
ns13))*100
UlResidualBLE
R_Retrans14
% PUSCH BLER for the
fourteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans15/UlTransmissi
on_Retrans14)*100
(sum (UlTransmission_
Retrans15)/sum
(UlTransmission_Retra
ns14))*100
UlResidualBLE
R_Retrans15
% PUSCH BLER for the
fifteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans16/UlTransmissi
on_Retrans15)*100
(sum (UlTransmission_
Retrans16)/sum
(UlTransmission_Retra
ns15))*100
UlResidualBLE
R_Retrans16
% PUSCH BLER for the
sixteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans17/UlTransmissi
on_Retrans16)*100
(sum (UlTransmission_
Retrans17)/sum
(UlTransmission_Retra
ns16))*100
UlResidualBLE
R_Retrans17
% PUSCH BLER for the
seventeenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans18/UlTransmissi
on_Retrans17)*100
(sum (UlTransmission_
Retrans18)/sum
(UlTransmission_Retra
ns17))*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 269 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
UlResidualBLE
R_Retrans18
% PUSCH BLER for the
eighteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans19/UlTransmissi
on_Retrans18)*100
(sum (UlTransmission_
Retrans19)/sum
(UlTransmission_Retra
ns18))*100
UlResidualBLE
R_Retrans19
% PUSCH BLER for the
nineteenth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans20/UlTransmissi
on_Retrans19)*100
(sum (UlTransmission_
Retrans20)/sum
(UlTransmission_Retra
ns19))*100
UlResidualBLE
R_Retrans20
% PUSCH BLER for the
twentieth HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans21/UlTransmissi
on_Retrans20)*100
(sum (UlTransmission_
Retrans21)/sum
(UlTransmission_Retra
ns20))*100
UlResidualBLE
R_Retrans21
% PUSCH BLER for the twenty
first HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans22/UlTransmissi
on_Retrans21)*100
(sum (UlTransmission_
Retrans22)/sum
(UlTransmission_Retra
ns21))*100
UlResidualBLE
R_Retrans22
% PUSCH BLER for the twenty
second HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans23/UlTransmissi
on_Retrans22)*100
(sum (UlTransmission_
Retrans23)/sum
(UlTransmission_Retra
ns22))*100
UlResidualBLE
R_Retrans23
% PUSCH BLER for the twenty
third HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans24/UlTransmissi
on_Retrans23)*100
(sum (UlTransmission_
Retrans24)/sum
(UlTransmission_Retra
ns23))*100
UlResidualBLE
R_Retrans24
% PUSCH BLER for the twenty
fourth HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans25/UlTransmissi
(sum (UlTransmission_
Retrans25)/sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 270 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
on_Retrans24)*100 (UlTransmission_Retra
ns24))*100
UlResidualBLE
R_Retrans25
% PUSCH BLER for the twenty
fifth HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans26/UlTransmissi
on_Retrans25)*100
(sum (UlTransmission_
Retrans26)/sum
(UlTransmission_Retra
ns25))*100
UlResidualBLE
R_Retrans26
% PUSCH BLER for the twenty
sixth HARQ retransmission
Y OW Period float 0-100 (UlTransmission_Ret
rans27/UlTransmissi
on_Retrans26)*100
(sum (UlTransmission_
Retrans27)/sum
(UlTransmission_Retra
ns26))*100
UlResidualBLE
R_Retrans27
% PUSCH BLER for the twenty
seventh HARQ
retransmission
Y OW Period float 0-100 (UlTransmission_Na
cked_Retrans27/UlT
ransmission_Retran
s27)*100
(sum (UlTransmission_
Nacked_Retrans27)/su
m (UlTransmission_
Retrans27))*100
DlTransmission
_Retrans0
count Number of initial PDSCH
HARQ transmissions
Y CC 5.12 s. int 0-2147483647 - -
DlTransmission
_Retrans1
count Number of first PDSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
DlTransmission
_Retrans2
count Number of second PDSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
DlTransmission
_Retrans3
count Number of third PDSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
DlTransmission
_Nacked_Retr
ans3
count Number of third PDSCH
HARQ retransmission
failures
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 271 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
UlTransmission
_Retrans0
count Number of initial PUSCH
HARQ transmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans1
count Number of first PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans2
count Number of second PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans3
count Number of third PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans4
count Number of fourth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans5
count Number of fifth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans6
count Number of sixth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans7
count Number of seventh PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans8
count Number of eighth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans9
count Number of ninth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans10
count Number of tenth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans11
count Number of eleventh PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 272 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
UlTransmission
_Retrans12
count Number of twelfth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans13
count Number of thirteenth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans14
count Number of fourteenth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans15
count Number of fifteenth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans16
count Number of sixteenth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans17
count Number of seventeenth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans18
count Number of eighteenth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans19
count Number of nineteenth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans20
count Number of twentieth PUSCH
HARQ retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans21
count Number of twenty first
PUSCH HARQ
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 273 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
retransmissions
UlTransmission
_Retrans22
count Number of twenty second
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans23
count Number of twenty third
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans24
count Number of twenty fourth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans25
count Number of twenty fifth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans26
count Number of twenty sixth
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Retrans27
count Number of twenty seventh
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
UlTransmission
_Nacked_Retr
ans27
count Number of twenty seventh
PUSCH HARQ
retransmissions
Y CC 5.12 s. int 0-2147483647 - -
DlResidualBLE
R_RetransMin
count Minimum value of
DlResidualBLER_Retrans
Y OW Period int 0-2147483647 - min (DlResidualBLER_
RetransMin)
DlResidualBLE count Maximum value of Y OW Period int 0-2147483647 - max (DlResidualBLER_
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 274 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
R_RetransMax DlResidualBLER_Retrans RetransMax)
DlResidualBLE
R_RetransAvg
ratio Average of distribution for
DlResidualBLER_Retrans
Average of distribution for
DlTransmission_Retrans
Y OW Period float 0-3.4*10 ^38 (DlTransmission_Re
trans1+DlTransmissi
on_Retrans2+DlTra
nsmission_Retrans3
)/DlTransmission_R
etrans0
(sum (DlTransmission_
Retrans1)+sum
(DlTransmission_Retra
ns2)+sum
(DlTransmission_Retra
ns3))/sum
(DlTransmission_Retra
ns0)
UlResidualBLE
R_RetransMin
count Minimum value of
UlResidualBLER_Retrans
Y OW Period int 0-2147483647 - min (UlResidualBLER_
RetransMin)
UlResidualBLE
R_RetransMax
count Maximum value of
UlResidualBLER_Retrans
Y OW Period int 0-2147483647 - max (UlResidualBLER_
RetransMax)
UlResidualBLE
R_RetransAvg
ratio Average of distribution for
UlResidualBLER_Retrans
Average of distribution for
UlTransmission_Retrans
Y OW Period float 0-3.4*10^38 (UlTransmission_Re
trans1+UlTransmissi
on_Retrans2+UlTra
nsmission_Retrans3
+UlTransmission_R
etrans4+UlTransmis
sion_Retrans5+UlTr
ansmission_Retrans
6+UlTransmission_
Retrans7+UlTransm
ission_Retrans8+Ul
Transmission_Retra
ns9+UlTransmission
(sum (UlTransmission_
Retrans1)+sum
(UlTransmission_Retra
ns2)+sum
(UlTransmission_Retra
ns3)+sum
(UlTransmission_Retra
ns4)+sum
(UlTransmission_Retra
ns5)+sum
(UlTransmission_Retra
ns6)+sum
(UlTransmission_Retra
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 275 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
_Retrans10+UlTran
smission_Retrans11
+UlTransmission_R
etrans12+UlTransmi
ssion_Retrans13+Ul
Transmission_Retra
ns14+UlTransmissio
n_Retrans15+UlTra
nsmission_Retrans1
6+UlTransmission_
Retrans17+UlTrans
mission_Retrans18
+UlTransmission_R
etrans19+UlTransmi
ssion_Retrans20+Ul
Transmission_Retra
ns21+UlTransmissio
n_Retrans22+UlTra
nsmission_Retrans2
3+UlTransmission_
Retrans24+UlTrans
mission_Retrans25
+UlTransmission_R
etrans26+UlTransmi
ssion_Retrans27)/Ul
Transmission_Retra
ns0
ns7)+sum
(UlTransmission_Retra
ns8)+sum
(UlTransmission_Retra
ns9)+sum
(UlTransmission_Retra
ns10)+sum
(UlTransmission_Retra
ns11)+sum
(UlTransmission_Retra
ns12)+sum
(UlTransmission_Retra
ns13)+sum
(UlTransmission_Retra
ns14) +sum
(UlTransmission_Retra
ns15)+sum
(UlTransmission_Retra
ns16)+sum
(UlTransmission_Retra
ns17)+sum
(UlTransmission_Retra
ns18)+sum
(UlTransmission_Retra
ns19)+sum
(UlTransmission_Retra
ns20)+sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 276 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
(UlTransmission_Retra
ns21)+sum
(UlTransmission_Retra
ns22)+sum
(UlTransmission_Retra
ns23)+sum
(UlTransmission_Retra
ns24)+sum
(UlTransmission_Retra
ns25)+sum
(UlTransmission_Retra
ns26)+sum
(UlTransmission_Retra
ns27))/sum
(UlTransmission_Retra
ns0)
DlResidualBLE
R_RetransNak
% PDSCH BLER for HARQ
Nak
Y OW Period float 0-100 DlTransmission_Na
cked_Retrans3/DlTr
ansmission_Retrans
0*100
sum (DlTransmission_
Nacked_Retrans3)/su
m (DlTransmission_
Retrans0)*100
UlResidualBLE
R_RetransNak
% HARQ Nak PUSCH BLER Y OW Period float 0-100 UlTransmission_Na
cked_Retrans27/UlT
ransmission_Retran
s0*100
sum (UlTransmission_
Nacked_Retrans27)/su
m (UlTransmission_
Retrans0)*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 277 of 427
2600-00FET7GAT 6.0
18 Timing Alignment TA statistics are based on values transmitted up by the MAC when the RRC Connection Request message is received. The timing adv
ance value gets smaller as the distance between the UE and the eNB gets closer.
18.1 Timing Alignment
Collects the TA statistics for each cell. The TA is collected in the unit of 16Ts when the RRC ConnectionRequest message is received
from the MAC.
Index
Name Range Description
cNum 0~2 Serving Cell Index
mcID 0~0 Subcell Index
(displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TimeAdvanceSection0 count distance (meter): 0~200,
16TS: from 0 to 2
Y CC event int 0~2147483647 - -
TimeAdvanceSection1 count distance (meter): 201~400,
16TS: from 3 to 5
Y CC event int 0~2147483647 - -
TimeAdvanceSection2 count distance (meter): 401~600,
16TS: from 6 to 7
Y CC event int 0~2147483647 - -
TimeAdvanceSection3 count distance (meter): 601~800, Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 278 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
16TS: from 8 to 10
TimeAdvanceSection4 count distance (meter): 801~1000,
16TS: from 11 to 12
Y CC event int 0~2147483647 - -
TimeAdvanceSection5 count distance (meter): 1001~1200,
16TS: from 13 to 15
Y CC event int 0~2147483647 - -
TimeAdvanceSection6 count distance (meter): 1201~1400,
16TS: from 16 to 17
Y CC event int 0~2147483647 - -
TimeAdvanceSection7 count distance (meter): 1401~1600,
16TS: from 18 to 20
Y CC event int 0~2147483647 - -
TimeAdvanceSection8 count distance (meter): 1601~1800,
16TS: from 21 to 22
Y CC event int 0~2147483647 - -
TimeAdvanceSection9 count distance (meter): 1801~2000,
16TS: from 23 to 25
Y CC event int 0~2147483647 - -
TimeAdvanceSection10 count distance (meter): 2001~2500,
16TS: from 26 to 31
Y CC event int 0~2147483647 - -
TimeAdvanceSection11 count distance (meter): 2501~3000,
16TS: from 32 to 38
Y CC event int 0~2147483647 - -
TimeAdvanceSection12 count distance (meter): 3001~3500,
16TS: from 39 to 44
Y CC event int 0~2147483647 - -
TimeAdvanceSection13 count distance (meter): 3501~4000,
16TS: from 45 to 50
Y CC event int 0~2147483647 - -
TimeAdvanceSection14 count distance (meter): 4001~5000,
16TS: from 51 to 63
Y CC event int 0~2147483647 - -
TimeAdvanceSection15 count distance (meter): 5001~6000, Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 279 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
16TS: from 64 to 76
TimeAdvanceSection16 count distance (meter): 6001~7000,
16TS: from 77 to 88
Y CC event int 0~2147483647 - -
TimeAdvanceSection17 count distance (meter): 7001~8000,
16TS: from 89 to 101
Y CC event int 0~2147483647 - -
TimeAdvanceSection18 count distance (meter): 8001~9000,
16TS: from 102 to 114
Y CC event int 0~2147483647 - -
TimeAdvanceSection19 count distance (meter): 9001~
10000, 16TS: from 115 to 126
Y CC event int 0~2147483647 - -
TimeAdvanceSection20 count distance (meter): 10001~,
16TS: from 127 to 1282
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 280 of 427
2600-00FET7GAT 6.0
19 AMC AMC provides MIMO performance, MCS performance, DL MCS, DL LAYER, DL CQI, DL PMI, DL RI, and DL ACK/NACK/DTX r
atio statistics. These statistics items are described in the following table.
19.1 MIMO Performance
This section provides statistics data for Block Error Rate (BLER) information for each layer for PUSCH/PDSCH.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer 1~4 Layer (data stream count)
1: 1 stream
2: 2 streams
3: 3 streams
4: 4 streams
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
Layer
% PDSCH BLER for each layer Y OW Period float 0-100 PdschBLERpe
rLayerTot/
PdschBLERpe
rLayerCnt*100
sum
(PdschBLERperLayerTot)/
sum
(PdschBLERperLayerCnt)
*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 281 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
LayerTot
count PDSCH error count for each
layer (all errors)
- CC 5 s float 0~3.4*10^38 - -
PdschBLERper
LayerCnt
count Total PDSCH count for each
layer
- CC 5 s int 0~2147483647 - -
PuschBLERper
Layer
% PUSCH BLER for each layer Y OW Period float 0-100 PuschBLERpe
rLayerTot/
PuschBLERpe
rLayerCnt*100
sum
(PuschBLERperLayerTot)/
sum
(PuschBLERperLayerCnt)
*100
PuschBLERper
LayerTot
count PUSCH error count for each
layer (all errors)
- CC 5 s float 0~3.4*10^38 - -
PuschBLERper
LayerCnt
count Total PUSCH count for each
layer
- CC 5 s int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 282 of 427
2600-00FET7GAT 6.0
19.2 MCS Performance
It provides information about PUSCH’s Block Error Rate (BLER), the number of allocated PRBs and the number of transmissions for
each MCS. For the PDSCH, it collects the Block Error Rate (BLER) and the number of allocated PRBs.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
MCS0
% PDSCH BLER
transmitted to MCS 0
Y OW Period float 0-100 PdschBLERperMCS0_
Tot/PdschBLERperMC
S0_Cnt*100
sum
(PdschBLERperMCS0_Tot)/
sum
(PdschBLERperMCS0_Cnt)
*100
PdschBLERper
MCS1
% PDSCH BLER
transmitted to MCS 1
Y OW Period float 0-100 PdschBLERperMCS1_
Tot/PdschBLERperMC
S1_Cnt*100
sum
(PdschBLERperMCS1_Tot)/
sum
(PdschBLERperMCS1_Cnt)
*100
PdschBLERper
MCS2
% PDSCH BLER
transmitted to MCS 2
Y OW Period float 0-100 PdschBLERperMCS2_
Tot/PdschBLERperMC
S2_Cnt*100
sum
(PdschBLERperMCS2_Tot)/
sum
(PdschBLERperMCS2_Cnt)*
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 283 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
100
PdschBLERper
MCS3
% PDSCH BLER
transmitted to MCS 3
Y OW Period float 0-100 PdschBLERperMCS3_
Tot/PdschBLERperMC
S3_Cnt*100
sum
(PdschBLERperMCS3_Tot)/
sum
(PdschBLERperMCS3_Cnt)
*100
PdschBLERper
MCS4
% PDSCH BLER
transmitted to MCS 4
Y OW Period float 0-100 PdschBLERperMCS4_
Tot/PdschBLERperMC
S4_Cnt*100
sum
(PdschBLERperMCS4_Tot)/
sum
(PdschBLERperMCS4_Cnt)
*100
PdschBLERper
MCS5
% PDSCH BLER
transmitted to MCS 5
Y OW Period float 0-100 PdschBLERperMCS5_
Tot/PdschBLERperMC
S5_Cnt*100
sum
(PdschBLERperMCS5_Tot)/
sum
(PdschBLERperMCS5_Cnt)
*100
PdschBLERper
MCS6
% PDSCH BLER
transmitted to MCS 6
Y OW Period float 0-100 PdschBLERperMCS6_
Tot/PdschBLERperMC
S6_Cnt*100
sum
(PdschBLERperMCS6_Tot)/
sum
(PdschBLERperMCS6_Cnt)
*100
PdschBLERper
MCS7
% PDSCH BLER
transmitted to MCS 7
Y OW Period float 0-100 PdschBLERperMCS7_
Tot/PdschBLERperMC
S7_Cnt*100
sum
(PdschBLERperMCS7_Tot)/
sum
(PdschBLERperMCS7_Cnt)*
100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 284 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
MCS8
% PDSCH BLER
transmitted to MCS 8
Y OW Period float 0-100 PdschBLERperMCS8_
Tot/PdschBLERperMC
S8_Cnt*100
sum
(PdschBLERperMCS8_Tot)/
sum
(PdschBLERperMCS8_Cnt)*
100
PdschBLERper
MCS9
% PDSCH BLER
transmitted to MCS 9
Y OW Period float 0-100 PdschBLERperMCS9_
Tot/PdschBLERperMC
S9_Cnt*100
sum
(PdschBLERperMCS9_Tot)/
sum
(PdschBLERperMCS9_Cnt)
*100
PdschBLERperM
CS10
% PDSCH BLER
transmitted to MCS
10
Y OW Period float 0-100 PdschBLERperMCS10
_Tot/PdschBLERperM
CS10_Cnt*100
sum
(PdschBLERperMCS10_Tot)/
sum
(PdschBLERperMCS10_Cnt)
*100
PdschBLERperM
CS11
% PDSCH BLER
transmitted to MCS
11
Y OW Period float 0-100 PdschBLERperMCS11
_Tot/PdschBLERperM
CS11_Cnt*100
sum
(PdschBLERperMCS11_Tot)/
sum
(PdschBLERperMCS11_Cnt)
*100
PdschBLERperM
CS12
% PDSCH BLER
transmitted to MCS
12
Y OW Period float 0-100 PdschBLERperMCS12
_Tot/PdschBLERperM
CS12_Cnt*100
sum
(PdschBLERperMCS12_Tot)/
sum
(PdschBLERperMCS12_Cnt)
*100
PdschBLERperM % PDSCH BLER Y OW Period float 0-100 PdschBLERperMCS13 sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 285 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
CS13 transmitted to MCS
13
_Tot/PdschBLERperM
CS13_Cnt*100
(PdschBLERperMCS13_Tot)/
sum
(PdschBLERperMCS13_Cnt)
*100
PdschBLERperM
CS14
% PDSCH BLER
transmitted to MCS
14
Y OW Period float 0-100 PdschBLERperMCS14
_Tot/PdschBLERperM
CS14_Cnt*100
sum
(PdschBLERperMCS14_Tot)/
sum
(PdschBLERperMCS14_Cnt)
*100
PdschBLERperM
CS15
% PDSCH BLER
transmitted to MCS
15
Y OW Period float 0-100 PdschBLERperMCS15
_Tot/PdschBLERperM
CS15_Cnt*100
sum
(PdschBLERperMCS15_Tot)/
sum
(PdschBLERperMCS15_Cnt)
*100
PdschBLERperM
CS16
% PDSCH BLER
transmitted to MCS
16
Y OW Period float 0-100 PdschBLERperMCS16
_Tot/PdschBLERperM
CS16_Cnt*100
sum
(PdschBLERperMCS16_Tot)/
sum
(PdschBLERperMCS16_Cnt)
*100
PdschBLERperM
CS17
% PDSCH BLER
transmitted to MCS
17
Y OW Period float 0-100 PdschBLERperMCS17
_Tot/PdschBLERperM
CS17_Cnt*100
sum
(PdschBLERperMCS17_Tot)/
sum
(PdschBLERperMCS17_Cnt)
*100
PdschBLERperM
CS18
% PDSCH BLER
transmitted to MCS
Y OW Period float 0-100 PdschBLERperMCS18
_Tot/PdschBLERperM
sum
(PdschBLERperMCS18_Tot)/
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 286 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
18 CS18_Cnt*100 sum
(PdschBLERperMCS18_Cnt)
*100
PdschBLERperM
CS19
% PDSCH BLER
transmitted to MCS
19
Y OW Period float 0-100 PdschBLERperMCS19
_Tot/PdschBLERperM
CS19_Cnt*100
sum
(PdschBLERperMCS19_Tot)/
sum
(PdschBLERperMCS19_Cnt)
*100
PdschBLERperM
CS20
% PDSCH BLER
transmitted to MCS
20
Y OW Period float 0-100 PdschBLERperMCS20
_Tot/PdschBLERperM
CS20_Cnt*100
sum
(PdschBLERperMCS20_Tot)/
sum
(PdschBLERperMCS20_Cnt)
*100
PdschBLERperM
CS21
% PDSCH BLER
transmitted to MCS
21
Y OW Period float 0-100 PdschBLERperMCS21
_Tot/PdschBLERperM
CS21_Cnt*100
sum
(PdschBLERperMCS21_Tot)/
sum
(PdschBLERperMCS21_Cnt)
*100
PdschBLERperM
CS22
% PDSCH BLER
transmitted to MCS
22
Y OW Period float 0-100 PdschBLERperMCS22
_Tot/PdschBLERperM
CS22_Cnt*100
sum
(PdschBLERperMCS22_Tot)/
sum
(PdschBLERperMCS22_Cnt)
*100
PdschBLERperM
CS23
% PDSCH BLER
transmitted to MCS
23
Y OW Period float 0-100 PdschBLERperMCS23
_Tot/PdschBLERperM
CS23_Cnt*100
sum
(PdschBLERperMCS23_Tot)/
sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 287 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
(PdschBLERperMCS23_Cnt)
*100
PdschBLERperM
CS24
% PDSCH BLER
transmitted to MCS
24
Y OW Period float 0-100 PdschBLERperMCS24
_Tot/PdschBLERperM
CS24_Cnt*100
sum
(PdschBLERperMCS24_Tot)/
sum
(PdschBLERperMCS24_Cnt)
*100
PdschBLERperM
CS25
% PDSCH BLER
transmitted to MCS
25
Y OW Period float 0-100 PdschBLERperMCS25
_Tot/PdschBLERperM
CS25_Cnt*100
sum
(PdschBLERperMCS25_Tot)/
sum
(PdschBLERperMCS25_Cnt)
*100
PdschBLERperM
CS26
% PDSCH BLER
transmitted to MCS
26
Y OW Period float 0-100 PdschBLERperMCS26
_Tot/PdschBLERperM
CS26_Cnt*100
sum
(PdschBLERperMCS26_Tot)/
sum
(PdschBLERperMCS26_Cnt)
*100
PdschBLERperM
CS27
% PDSCH BLER
transmitted to MCS
27
Y OW Period float 0-100 PdschBLERperMCS27
_Tot/PdschBLERperM
CS27_Cnt*100
sum
(PdschBLERperMCS27_Tot)/
sum
(PdschBLERperMCS27_Cnt)
*100
PdschBLERperM
CS28
% PDSCH BLER
transmitted to MCS
28
Y OW Period float 0-100 PdschBLERperMCS28
_Tot/PdschBLERperM
CS28_Cnt*100
sum
(PdschBLERperMCS28_Tot)/
sum
(PdschBLERperMCS28_Cnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 288 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
*100
PdschBLERperM
CS29
% PDSCH BLER
transmitted to MCS
29
Y OW Period float 0-100 PdschBLERperMCS29
_Tot/PdschBLERperM
CS29_Cnt*100
sum
(PdschBLERperMCS29_Tot)/
sum
(PdschBLERperMCS29_Cnt)
*100
PdschBLERperM
CS30
% PDSCH BLER
transmitted to MCS
30
Y OW Period float 0-100 PdschBLERperMCS30
_Tot/PdschBLERperM
CS30_Cnt*100
sum
(PdschBLERperMCS30_Tot)/
sum
(PdschBLERperMCS30_Cnt)
*100
PdschBLERperM
CS31
% PDSCH BLER
transmitted to MCS
31
Y OW Period float 0-100 PdschBLERperMCS31
_Tot/PdschBLERperM
CS31_Cnt*100
sum
(PdschBLERperMCS31_Tot)/
sum
(PdschBLERperMCS31_Cnt)
*100
PdschBLERper
MCS0_Tot
count PDSCH Error count
transmitted to MCS 0
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS1_Tot
count PDSCH Error count
transmitted to MCS 1
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS2_Tot
count PDSCH Error count
transmitted to MCS 2
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper count PDSCH Error count Y CC 5 s float 0~3.4*10^ - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 289 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS3_Tot transmitted to MCS 3
(all errors)
38
PdschBLERper
MCS4_Tot
count PDSCH Error count
transmitted to MCS 4
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS5_Tot
count PDSCH Error count
transmitted to MCS 5
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS6_Tot
count PDSCH Error count
transmitted to MCS 6
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS7_Tot
count PDSCH Error count
transmitted to MCS 7
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS8_Tot
count PDSCH Error count
transmitted to MCS 8
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS9_Tot
count PDSCH Error count
transmitted to MCS 9
(all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS10_Tot
count PDSCH Error count
transmitted to MCS
10 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS11_Tot
count PDSCH Error count
transmitted to MCS
Y CC 5 s float 0~3.4*10^
38
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 290 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
11 (all errors)
PdschBLERper
MCS12_Tot
count PDSCH Error count
transmitted to MCS
12 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS13_Tot
count PDSCH Error count
transmitted to MCS
13 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS14_Tot
count PDSCH Error count
transmitted to MCS
14 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS15_Tot
count PDSCH Error count
transmitted to MCS
15 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS16_Tot
count PDSCH Error count
transmitted to MCS
16 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS17_Tot
count PDSCH Error count
transmitted to MCS
17 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS18_Tot
count PDSCH Error count
transmitted to MCS
18 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS19_Tot
count PDSCH Error count
transmitted to MCS
19 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 291 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
MCS20_Tot
count PDSCH Error count
transmitted to MCS
20 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS21_Tot
count PDSCH Error count
transmitted to MCS
21 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS22_Tot
count PDSCH Error count
transmitted to MCS
22 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS23_Tot
count PDSCH Error count
transmitted to MCS
23 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS24_Tot
count PDSCH Error count
transmitted to MCS
24 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS25_Tot
count PDSCH Error count
transmitted to MCS
25 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS26_Tot
count PDSCH Error count
transmitted to MCS
26 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS27_Tot
count PDSCH Error count
transmitted to MCS
27 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper count PDSCH Error count Y CC 5 s float 0~3.4*10^ - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 292 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS28_Tot transmitted to MCS
28 (all errors)
38
PdschBLERper
MCS29_Tot
count PDSCH Error count
transmitted to MCS
29 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS30_Tot
count PDSCH Error count
transmitted to MCS
30 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS31_Tot
count PDSCH Error count
transmitted to MCS
31 (all errors)
Y CC 5 s float 0~3.4*10^
38
- -
PdschBLERper
MCS0_Cnt
count Total PDSCH count
transmitted to MCS 0
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS1_Cnt
count Total PDSCH count
transmitted to MCS 1
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS2_Cnt
count Total PDSCH count
transmitted to MCS 2
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS3_Cnt
count Total PDSCH count
transmitted to MCS 3
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS4_Cnt
count Total PDSCH count
transmitted to MCS 4
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS5_Cnt
count Total PDSCH count
transmitted to MCS 5
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS6_Cnt
count Total PDSCH count
transmitted to MCS 6
Y CC 5 s int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 293 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PdschBLERper
MCS7_Cnt
count Total PDSCH count
transmitted to MCS 7
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS8_Cnt
count Total PDSCH count
transmitted to MCS 8
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS9_Cnt
count Total PDSCH count
transmitted to MCS 9
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS10_Cnt
count Total PDSCH count
transmitted to MCS
10
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS11_Cnt
count Total PDSCH count
transmitted to MCS
11
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS12_Cnt
count Total PDSCH count
transmitted to MCS
12
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS13_Cnt
count Total PDSCH count
transmitted to MCS
13
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS14_Cnt
count Total PDSCH count
transmitted to MCS
14
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS15_Cnt
count Total PDSCH count
transmitted to MCS
15
Y CC 5 s int 0~214748
3647
- -
PdschBLERper count Total PDSCH count Y CC 5 s int 0~214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 294 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS16_Cnt transmitted to MCS
16
3647
PdschBLERper
MCS17_Cnt
count Total PDSCH count
transmitted to MCS
17
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS18_Cnt
count Total PDSCH count
transmitted to MCS
18
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS19_Cnt
count Total PDSCH count
transmitted to MCS
19
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS20_Cnt
count Total PDSCH count
transmitted to MCS
20
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS21_Cnt
count Total PDSCH count
transmitted to MCS
21
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS22_Cnt
count Total PDSCH count
transmitted to MCS
22
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS23_Cnt
count Total PDSCH count
transmitted to MCS
23
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS24_Cnt
count Total PDSCH count
transmitted to MCS
Y CC 5 s int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 295 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
24
PdschBLERper
MCS25_Cnt
count Total PDSCH count
transmitted to MCS
25
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS26_Cnt
count Total PDSCH count
transmitted to MCS
26
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS27_Cnt
count Total PDSCH count
transmitted to MCS
27
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS28_Cnt
count Total PDSCH count
transmitted to MCS
28
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS29_Cnt
count Total PDSCH count
transmitted to MCS
29
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS30_Cnt
count Total PDSCH count
transmitted to MCS
30
Y CC 5 s int 0~214748
3647
- -
PdschBLERper
MCS31_Cnt
count Total PDSCH count
transmitted to MCS
31
Y CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS0
% PUSCH BLER
received to MCS 0
Y OW Period float 0-100 PuschBLERperMCS0_
Tot/PuschBLERperMC
S0_Cnt*100
sum
(PuschBLERperMCS0_Tot)/
sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 296 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
(PuschBLERperMCS0_Cnt)
*100
PuschBLERper
MCS1
% PUSCH BLER
received to MCS 1
Y OW Period float 0-100 PuschBLERperMCS1_
Tot/PuschBLERperMC
S1_Cnt*100
sum
(PuschBLERperMCS1_Tot)/
sum
(PuschBLERperMCS1_Cnt)
*100
PuschBLERper
MCS2
% PUSCH BLER
received to MCS 2
Y OW Period float 0-100 PuschBLERperMCS2_
Tot/PuschBLERperMC
S2_Cnt*100
sum
(PuschBLERperMCS2_Tot)/
sum
(PuschBLERperMCS2_Cnt)
*100
PuschBLERper
MCS3
% PUSCH BLER
received to MCS 3
Y OW Period float 0-100 PuschBLERperMCS3_
Tot/PuschBLERperMC
S3_Cnt*100
sum
(PuschBLERperMCS3_Tot)/
sum
(PuschBLERperMCS3_Cnt)
*100
PuschBLERper
MCS4
% PUSCH BLER
received to MCS 4
Y OW Period float 0-100 PuschBLERperMCS4_
Tot/PuschBLERperMC
S4_Cnt*100
sum
(PuschBLERperMCS4_Tot)/
sum
(PuschBLERperMCS4_Cnt)
*100
PuschBLERper
MCS5
% PUSCH BLER
received to MCS 5
Y OW Period float 0-100 PuschBLERperMCS5_
Tot/PuschBLERperMC
S5_Cnt*100
sum
(PuschBLERperMCS5_Tot)/
sum
(PuschBLERperMCS5_Cnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 297 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
*100
PuschBLERper
MCS6
% PUSCH BLER
received to MCS 6
Y OW Period float 0-100 PuschBLERperMCS6_
Tot/PuschBLERperMC
S6_Cnt*100
sum
(PuschBLERperMCS6_Tot)/
sum
(PuschBLERperMCS6_Cnt)
*100
PuschBLERper
MCS7
% PUSCH BLER
received to MCS 7
Y OW Period float 0-100 PuschBLERperMCS7_
Tot/PuschBLERperMC
S7_Cnt*100
sum
(PuschBLERperMCS7_Tot)/
sum
(PuschBLERperMCS7_Cnt)
*100
PuschBLERper
MCS8
% PUSCH BLER
received to MCS 8
Y OW Period float 0-100 PuschBLERperMCS8_
Tot/PuschBLERperMC
S8_Cnt*100
sum
(PuschBLERperMCS8_Tot)/
sum
(PuschBLERperMCS8_Cnt)
*100
PuschBLERper
MCS9
% PUSCH BLER
received to MCS 9
Y OW Period float 0-100 PuschBLERperMCS9_
Tot/PuschBLERperMC
S9_Cnt*100
sum
(PuschBLERperMCS9_Tot)/
sum
(PuschBLERperMCS9_Cnt)
*100
PuschBLERperM
CS10
% PUSCH BLER
received to MCS 10
Y OW Period float 0-100 PuschBLERperMCS10
_Tot/PuschBLERperM
CS10_Cnt*100
sum
(PuschBLERperMCS10_Tot)/
sum
(PuschBLERperMCS10_Cnt)
*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 298 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PuschBLERperM
CS11
% PUSCH BLER
received to MCS 11
Y OW Period float 0-100 PuschBLERperMCS11
_Tot/PuschBLERperM
CS11_Cnt*100
sum
(PuschBLERperMCS11_Tot)/
sum
(PuschBLERperMCS11_Cnt)
*100
PuschBLERperM
CS12
% PUSCH BLER
received to MCS 12
Y OW Period float 0-100 PuschBLERperMCS12
_Tot/PuschBLERperM
CS12_Cnt*100
sum
(PuschBLERperMCS12_Tot)/
sum
(PuschBLERperMCS12_Cnt)
*100
PuschBLERperM
CS13
% PUSCH BLER
received to MCS 13
Y OW Period float 0-100 PuschBLERperMCS13
_Tot/PuschBLERperM
CS13_Cnt*100
sum
(PuschBLERperMCS13_Tot)/
sum
(PuschBLERperMCS13_Cnt)
*100
PuschBLERperM
CS14
% PUSCH BLER
received to MCS 14
Y OW Period float 0-100 PuschBLERperMCS14
_Tot/PuschBLERperM
CS14_Cnt*100
sum
(PuschBLERperMCS14_Tot)/
sum
(PuschBLERperMCS14_Cnt)
*100
PuschBLERperM
CS15
% PUSCH BLER
received to MCS 15
Y OW Period float 0-100 PuschBLERperMCS15
_Tot/PuschBLERperM
CS15_Cnt*100
sum
(PuschBLERperMCS15_Tot)/
sum
(PuschBLERperMCS15_Cnt)
*100
PuschBLERperM % PUSCH BLER Y OW Period float 0-100 PuschBLERperMCS16 sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 299 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
CS16 received to MCS 16 _Tot/PuschBLERperM
CS16_Cnt*100
(PuschBLERperMCS16_Tot)/
sum
(PuschBLERperMCS16_Cnt)
*100
PuschBLERperM
CS17
% PUSCH BLER
received to MCS 17
Y OW Period float 0-100 PuschBLERperMCS17
_Tot/PuschBLERperM
CS17_Cnt*100
sum
(PuschBLERperMCS17_Tot)/
sum
(PuschBLERperMCS17_Cnt)
*100
PuschBLERperM
CS18
% PUSCH BLER
received to MCS 18
Y OW Period float 0-100 PuschBLERperMCS18
_Tot/PuschBLERperM
CS18_Cnt*100
sum
(PuschBLERperMCS18_Tot)/
sum
(PuschBLERperMCS18_Cnt)
*100
PuschBLERperM
CS19
% PUSCH BLER
received to MCS 19
Y OW Period float 0-100 PuschBLERperMCS19
_Tot/PuschBLERperM
CS19_Cnt*100
sum
(PuschBLERperMCS19_Tot)/
sum
(PuschBLERperMCS19_Cnt)
*100
PuschBLERperM
CS20
% PUSCH BLER
received to MCS 20
Y OW Period float 0-100 PuschBLERperMCS20
_Tot/PuschBLERperM
CS20_Cnt*100
sum
(PuschBLERperMCS20_Tot)/
sum
(PuschBLERperMCS20_Cnt)
*100
PuschBLERperM
CS21
% PUSCH BLER
received to MCS 21
Y OW Period float 0-100 PuschBLERperMCS21
_Tot/PuschBLERperM
sum
(PuschBLERperMCS21_Tot)/
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 300 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
CS21_Cnt*100 sum
(PuschBLERperMCS21_Cnt)
*100
PuschBLERperM
CS22
% PUSCH BLER
received to MCS 22
Y OW Period float 0-100 PuschBLERperMCS22
_Tot/PuschBLERperM
CS22_Cnt*100
sum
(PuschBLERperMCS22_Tot)/
sum
(PuschBLERperMCS22_Cnt)
*100
PuschBLERperM
CS23
% PUSCH BLER
received to MCS 23
Y OW Period float 0-100 PuschBLERperMCS23
_Tot/PuschBLERperM
CS23_Cnt*100
sum
(PuschBLERperMCS23_Tot)/
sum
(PuschBLERperMCS23_Cnt)
*100
PuschBLERperM
CS24
% PUSCH BLER
received to MCS 24
Y OW Period float 0-100 PuschBLERperMCS24
_Tot/PuschBLERperM
CS24_Cnt*100
sum
(PuschBLERperMCS24_Tot)/
sum
(PuschBLERperMCS24_Cnt)
*100
PuschBLERperM
CS25
% PUSCH BLER
received to MCS 25
Y OW Period float 0-100 PuschBLERperMCS25
_Tot/PuschBLERperM
CS25_Cnt*100
sum
(PuschBLERperMCS25_Tot)/
sum
(PuschBLERperMCS25_Cnt)
*100
PuschBLERperM
CS26
% PUSCH BLER
received to MCS 26
Y OW Period float 0-100 PuschBLERperMCS26
_Tot/PuschBLERperM
CS26_Cnt*100
sum
(PuschBLERperMCS26_Tot)/
sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 301 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
(PuschBLERperMCS26_Cnt)
*100
PuschBLERperM
CS27
% PUSCH BLER
received to MCS 27
Y OW Period float 0-100 PuschBLERperMCS27
_Tot/PuschBLERperM
CS27_Cnt*100
sum
(PuschBLERperMCS27_Tot)/
sum
(PuschBLERperMCS27_Cnt)
*100
PuschBLERperM
CS28
% PUSCH BLER
received to MCS 28
Y OW Period float 0-100 PuschBLERperMCS28
_Tot/PuschBLERperM
CS28_Cnt*100
sum
(PuschBLERperMCS28_Tot)/
sum
(PuschBLERperMCS28_Cnt)
*100
PuschBLERperM
CS29
% PUSCH BLER
received to MCS 29
Y OW Period float 0-100 PuschBLERperMCS29
_Tot/PuschBLERperM
CS29_Cnt*100
sum
(PuschBLERperMCS29_Tot)/
sum
(PuschBLERperMCS29_Cnt)
*100
PuschBLERperM
CS30
% PUSCH BLER
received to MCS 30
Y OW Period float 0-100 PuschBLERperMCS30
_Tot/PuschBLERperM
CS30_Cnt*100
sum
(PuschBLERperMCS30_Tot)/
sum
(PuschBLERperMCS30_Cnt)
*100
PuschBLERperM
CS31
% PUSCH BLER
received to MCS 31
Y OW Period float 0-100 PuschBLERperMCS31
_Tot/PuschBLERperM
CS31_Cnt*100
sum
(PuschBLERperMCS31_Tot)/
sum
(PuschBLERperMCS31_Cnt)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 302 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
*100
PuschBLERper
MCS0_Tot
count PUSCH Error count
transmitted to MCS 0
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS1_Tot
count PUSCH Error count
transmitted to MCS 1
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS2_Tot
count PUSCH Error count
transmitted to MCS 2
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS3_Tot
count PUSCH Error count
transmitted to MCS 3
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS4_Tot
count PUSCH Error count
transmitted to MCS 4
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS5_Tot
count PUSCH Error count
transmitted to MCS 5
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS6_Tot
count PUSCH Error count
transmitted to MCS 6
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS7_Tot
count PUSCH Error count
transmitted to MCS 7
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 303 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PuschBLERper
MCS8_Tot
count PUSCH Error count
transmitted to MCS 8
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS9_Tot
count PUSCH Error count
transmitted to MCS 9
(all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS10_Tot
count PUSCH Error count
transmitted to MCS
10 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS11_Tot
count PUSCH Error count
transmitted to MCS
11 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS12_Tot
count PUSCH Error count
transmitted to MCS
12 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS13_Tot
count PUSCH Error count
transmitted to MCS
13 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS14_Tot
count PUSCH Error count
transmitted to MCS
14 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS15_Tot
count PUSCH Error count
transmitted to MCS
15 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper count PUSCH Error count - CC 5 s float 0~3.4*10^ - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 304 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS16_Tot transmitted to MCS
16 (all errors)
38
PuschBLERper
MCS17_Tot
count PUSCH Error count
transmitted to MCS
17 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS18_Tot
count PUSCH Error count
transmitted to MCS
18 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS19_Tot
count PUSCH Error count
transmitted to MCS
19 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS20_Tot
count PUSCH Error count
transmitted to MCS
20 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS21_Tot
count PUSCH Error count
transmitted to MCS
21 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS22_Tot
count PUSCH Error count
transmitted to MCS
22 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS23_Tot
count PUSCH Error count
transmitted to MCS
23 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS24_Tot
count PUSCH Error count
transmitted to MCS
- CC 5 s float 0~3.4*10^
38
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 305 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
24 (all errors)
PuschBLERper
MCS25_Tot
count PUSCH Error count
transmitted to MCS
25 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS26_Tot
count PUSCH Error count
transmitted to MCS
26 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS27_Tot
count PUSCH Error count
transmitted to MCS
27 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS28_Tot
count PUSCH Error count
transmitted to MCS
28 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS29_Tot
count PUSCH Error count
transmitted to MCS
29 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS30_Tot
count PUSCH Error count
transmitted to MCS
30 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS31_Tot
count PUSCH Error count
transmitted to MCS
31 (all errors)
- CC 5 s float 0~3.4*10^
38
- -
PuschBLERper
MCS0_Cnt
count Total PUSCH count
transmitted to MCS 0
- CC 5 s int 0~214748
3647
- -
PuschBLERper count Total PUSCH count - CC 5 s int 0~214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 306 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS1_Cnt transmitted to MCS 1 3647
PuschBLERper
MCS2_Cnt
count Total PUSCH count
transmitted to MCS 2
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS3_Cnt
count Total PUSCH count
transmitted to MCS 3
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS4_Cnt
count Total PUSCH count
transmitted to MCS 4
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS5_Cnt
count Total PUSCH count
transmitted to MCS 5
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS6_Cnt
count Total PUSCH count
transmitted to MCS 6
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS7_Cnt
count Total PUSCH count
transmitted to MCS 7
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS8_Cnt
count Total PUSCH count
transmitted to MCS 8
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS9_Cnt
count Total PUSCH count
transmitted to MCS 9
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS10_Cnt
count Total PUSCH count
transmitted to MCS
10
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS11_Cnt
count Total PUSCH count
transmitted to MCS
11
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS12_Cnt
count Total PUSCH count
transmitted to MCS
- CC 5 s int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 307 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
12
PuschBLERper
MCS13_Cnt
count Total PUSCH count
transmitted to MCS
13
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS14_Cnt
count Total PUSCH count
transmitted to MCS
14
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS15_Cnt
count Total PUSCH count
transmitted to MCS
15
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS16_Cnt
count Total PUSCH count
transmitted to MCS
16
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS17_Cnt
count Total PUSCH count
transmitted to MCS
17
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS18_Cnt
count Total PUSCH count
transmitted to MCS
18
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS19_Cnt
count Total PUSCH count
transmitted to MCS
19
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS20_Cnt
count Total PUSCH count
transmitted to MCS
20
- CC 5 s int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 308 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
PuschBLERper
MCS21_Cnt
count Total PUSCH count
transmitted to MCS
21
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS22_Cnt
count Total PUSCH count
transmitted to MCS
22
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS23_Cnt
count Total PUSCH count
transmitted to MCS
23
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS24_Cnt
count Total PUSCH count
transmitted to MCS
24
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS25_Cnt
count Total PUSCH count
transmitted to MCS
25
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS26_Cnt
count Total PUSCH count
transmitted to MCS
26
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS27_Cnt
count Total PUSCH count
transmitted to MCS
27
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS28_Cnt
count Total PUSCH count
transmitted to MCS
28
- CC 5 s int 0~214748
3647
- -
PuschBLERper count Total PUSCH count - CC 5 s int 0~214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 309 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS29_Cnt transmitted to MCS
29
3647
PuschBLERper
MCS30_Cnt
count Total PUSCH count
transmitted to MCS
30
- CC 5 s int 0~214748
3647
- -
PuschBLERper
MCS31_Cnt
count Total PUSCH count
transmitted to MCS
31
- CC 5 s int 0~214748
3647
- -
UlReceivedMCS
0
count The number of times
PUSCH of MCS 0 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
1
count The number of times
PUSCH of MCS 1 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
2
count The number of times
PUSCH of MCS 2 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
3
count The number of times
PUSCH of MCS 3 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
4
count The number of times
PUSCH of MCS 4 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
5
count The number of times
PUSCH of MCS 5 is
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 310 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
received
UlReceivedMCS
6
count The number of times
PUSCH of MCS 6 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
7
count The number of times
PUSCH of MCS 7 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
8
count The number of times
PUSCH of MCS 8 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
9
count The number of times
PUSCH of MCS 9 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
10
count The number of times
PUSCH of MCS 10 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
11
count The number of times
PUSCH of MCS 11 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
12
count The number of times
PUSCH of MCS 12 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
13
count The number of times
PUSCH of MCS 13 is
received
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 311 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
UlReceivedMCS
14
count The number of times
PUSCH of MCS 14 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
15
count The number of times
PUSCH of MCS 15 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
16
count The number of times
PUSCH of MCS 16 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
17
count The number of times
PUSCH of MCS 17 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
18
count The number of times
PUSCH of MCS 18 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
19
count The number of times
PUSCH of MCS 19 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
20
count The number of times
PUSCH of MCS 20 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
21
count The number of times
PUSCH of MCS 21 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS count The number of times Y CC 5.12 s. int 0-214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 312 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
22 PUSCH of MCS 22 is
received
3647
UlReceivedMCS
23
count The number of times
PUSCH of MCS 23 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
24
count The number of times
PUSCH of MCS 24 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
25
count The number of times
PUSCH of MCS 25 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
26
count The number of times
PUSCH of MCS 26 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
27
count The number of times
PUSCH of MCS 27 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
28
count The number of times
PUSCH of MCS 28 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
29
count The number of times
PUSCH of MCS 29 is
received
Y CC 5.12 s. int 0-214748
3647
- -
UlReceivedMCS
30
count The number of times
PUSCH of MCS 30 is
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 313 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
received
UlReceivedMCS
31
count The number of times
PUSCH of MCS 31 is
received
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S0
count The number of PRBs
assigned to PDSCH
MCS 0
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S1
count The number of PRBs
assigned to DSCH
MCS 1
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S2
count The number of PRBs
assigned to DSCH
MCS 2
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S3
count The number of PRBs
assigned to DSCH
MCS 3
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S4
count The number of PRBs
assigned to DSCH
MCS 4
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S5
count The number of PRBs
assigned to DSCH
MCS 5
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S6
count The number of PRBs
assigned to DSCH
MCS 6
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 314 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
DlSchedulerMC
S7
count The number of PRBs
assigned to DSCH
MCS 7
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S8
count The number of PRBs
assigned to DSCH
MCS 8
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S9
count The number of PRBs
assigned to DSCH
MCS 9
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S10
count The number of PRBs
assigned to DSCH
MCS 10
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S11
count The number of PRBs
assigned to DSCH
MCS 11
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S12
count The number of PRBs
assigned to DSCH
MCS 12
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S13
count The number of PRBs
assigned to DSCH
MCS 13
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S14
count The number of PRBs
assigned to PDSCH
MCS 14
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC count The number of PRBs Y CC 5.12 s. int 0-214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 315 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
S15 assigned to PDSCH
MCS 15
3647
DlSchedulerMC
S16
count The number of PRBs
assigned to PDSCH
MCS 16
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S17
count The number of PRBs
assigned to PDSCH
MCS 17
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S18
count The number of PRBs
assigned to PDSCH
MCS 18
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S19
count The number of PRBs
assigned to PDSCH
MCS 19
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S20
count The number of PRBs
assigned to PDSCH
MCS 20
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S21
count The number of PRBs
assigned to PDSCH
MCS 21
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S22
count The number of PRBs
assigned to PDSCH
MCS 22
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S23
count The number of PRBs
assigned to PDSCH
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 316 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS 23
DlSchedulerMC
S24
count The number of PRBs
assigned to PDSCH
MCS 24
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S25
count The number of PRBs
assigned to PDSCH
MCS 25
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S26
count The number of PRBs
assigned to PDSCH
MCS 26
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S27
count The number of PRBs
assigned to PDSCH
MCS 27
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S28
count The number of PRBs
assigned to PDSCH
MCS 28
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S29
count The number of PRBs
assigned to PDSCH
MCS 29
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S30
count The number of PRBs
assigned to PDSCH
MCS 30
Y CC 5.12 s. int 0-214748
3647
- -
DlSchedulerMC
S31
count The number of PRBs
assigned to PDSCH
MCS 31
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 317 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
UlSchedulerMC
S0
count The number of PRBs
assigned to PUSCH
MCS 0
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S1
count The number of PRBs
assigned to PUSCH
MCS 1
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S2
count The number of PRBs
assigned to PUSCH
MCS 2
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S3
count The number of PRBs
assigned to PUSCH
MCS 3
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S4
count The number of PRBs
assigned to PUSCH
MCS 4
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S5
count The number of PRBs
assigned to PUSCH
MCS 5
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S6
count The number of PRBs
assigned to PUSCH
MCS 6
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S7
count The number of PRBs
assigned to PUSCH
MCS 7
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC count The number of PRBs Y CC 5.12 s. int 0-214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 318 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
S8 assigned to PUSCH
MCS 8
3647
UlSchedulerMC
S9
count The number of PRBs
assigned to PUSCH
MCS 9
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S10
count The number of PRBs
assigned to PUSCH
MCS 10
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S11
count The number of PRBs
assigned to PUSCH
MCS 11
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S12
count The number of PRBs
assigned to PUSCH
MCS 12
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S13
count The number of PRBs
assigned to PUSCH
MCS 13
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S14
count The number of PRBs
assigned to PUSCH
MCS 14
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S15
count The number of PRBs
assigned to PUSCH
MCS 15
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S16
count The number of PRBs
assigned to PUSCH
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 319 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
MCS 16
UlSchedulerMC
S17
count The number of PRBs
assigned to PUSCH
MCS 17
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S18
count The number of PRBs
assigned to PUSCH
MCS 18
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S19
count The number of PRBs
assigned to PUSCH
MCS 19
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S20
count The number of PRBs
assigned to PUSCH
MCS 20
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S21
count The number of PRBs
assigned to PUSCH
MCS 21
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S22
count The number of PRBs
assigned to PUSCH
MCS 22
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S23
count The number of PRBs
assigned to PUSCH
MCS 23
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S24
count The number of PRBs
assigned to PUSCH
MCS 24
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 320 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
UlSchedulerMC
S25
count The number of PRBs
assigned to PUSCH
MCS 25
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S26
count The number of PRBs
assigned to PUSCH
MCS 26
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S27
count The number of PRBs
assigned to PUSCH
MCS 27
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S28
count The number of PRBs
assigned to PUSCH
MCS 28
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S29
count The number of PRBs
assigned to PUSCH
MCS 29
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S30
count The number of PRBs
assigned to PUSCH
MCS 30
Y CC 5.12 s. int 0-214748
3647
- -
UlSchedulerMC
S31
count The number of PRBs
assigned to PUSCH
MCS 31
Y CC 5.12 s. int 0-214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 321 of 427
2600-00FET7GAT 6.0
19.3 DL MCS
This section provides statistics data for transmission counts per MCS/layer/Codeword for PDSCH.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer 1~4 Layer (data stream count)
1: 1 stream
2: 2 streams
3: 3 streams
4: 4 streams
Codeword 0~1 Codeword (Transport block count)
0: First transport block
1: Second transport block
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlTransmittedMC
S0
count The number of times that MCS 0
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S1
count The number of times that MCS 1
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 322 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlTransmittedMC
S2
count The number of times that MCS 2
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S3
count The number of times that MCS 3
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S4
count The number of times that MCS 4
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S5
count The number of times that MCS 5
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S6
count The number of times that MCS 6
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S7
count The number of times that MCS 7
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S8
count The number of times that MCS 8
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S9
count The number of times that MCS 9
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC count The number of times that MCS 10 Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 323 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S10 PDSCH is transmitted per layer/
codeword
DlTransmittedMC
S11
count The number of times that MCS 11
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S12
count The number of times that MCS 12
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S13
count The number of times that MCS 13
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S14
count The number of times that MCS 14
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S15
count The number of times that MCS 15
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S16
count The number of times that MCS 16
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S17
count The number of times that MCS 17
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S18
count The number of times that MCS 18
PDSCH is transmitted per layer/
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 324 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
codeword
DlTransmittedMC
S19
count The number of times that MCS 19
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S20
count The number of times that MCS 20
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S21
count The number of times that MCS 21
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S22
count The number of times that MCS 22
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S23
count The number of times that MCS 23
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S24
count The number of times that MCS 24
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S25
count The number of times that MCS 25
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S26
count The number of times that MCS 26
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 325 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlTransmittedMC
S27
count The number of times that MCS 27
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S28
count The number of times that MCS 28
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S29
count The number of times that MCS 29
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S30
count The number of times that MCS 30
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
DlTransmittedMC
S31
count The number of times that MCS 31
PDSCH is transmitted per layer/
codeword
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 326 of 427
2600-00FET7GAT 6.0
19.4 DL LAYER
This section provides statistics for data transmission counts per layer for PDSCH.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer 1~4 Layer (data stream count)
1: 1 stream
2: 2 streams
3: 3 streams
4: 4 streams
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlTransmittedLayer count Transmission counts
per layer for PDSCH
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 327 of 427
2600-00FET7GAT 6.0
19.5 DL CQI
This section provides CQI report information per layer/codeword for the UE
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer 1~4 Layer (data stream count)
1: 1 stream
2: 2 streams
3: 3 streams
4: 4 streams
Codeword 0~1 Codeword
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlReceivedCQI0 count The number of times that CQI 0
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI1 count The number of times that CQI 1
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI2 count The number of times that CQI 2
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI3 count The number of times that CQI 3
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 328 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlReceivedCQI4 count The number of times that CQI 4
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI5 count The number of times that CQI 5
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI6 count The number of times that CQI 6
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI7 count The number of times that CQI 7
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI8 count The number of times that CQI 8
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI9 count The number of times that CQI 9
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI10 count The number of times that CQI 10
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI11 count The number of times that CQI 11
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI12 count The number of times that CQI 12
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI13 count The number of times that CQI 13
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI14 count The number of times that CQI 14
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
DlReceivedCQI15 count The number of times that CQI 15
is received per layer/codeword
Y CC 5.12 s. int 0-21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 329 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlReceivedCQIMin CQI Minimum value of DlReceivedCQI Y OW Period int 0-15 - min
(DlReceivedCQIMin)
DlReceivedCQIMax CQI Maximum value of DlReceivedCQI Y OW Period int 0-15 - max
(DlReceivedCQIMax)
DlReceivedCQIAvg CQI Average value of DlReceivedCQI Y OW Period float 0-15 (0*DlReceivedC
QI0+1*DlReceive
dCQI1+2*DlRece
ivedCQI2+3*DlR
eceivedCQI3+4*
DlReceivedCQI4
+5*DlReceivedC
QI5+6*DlReceive
dCQI6+7*DlRece
ivedCQI7+8*DlR
eceivedCQI8+9*
DlReceivedCQI9
+10*DlReceived
CQI10+11*DlRec
eivedCQI11+12*
DlReceivedCQI1
2+13*DlReceive
dCQI13+14*DlR
eceivedCQI14+1
5*DlReceivedCQ
I15)/(DlReceived
CQI0+DlReceive
dCQI1+DlReceiv
(0*sum
(DlReceivedCQI0)+1*
sum
(DlReceivedCQI1)+2*
sum
(DlReceivedCQI2)+3*
sum
(DlReceivedCQI3)+4*
sum
(DlReceivedCQI4)+5*
sum
(DlReceivedCQI5)+6*
sum
(DlReceivedCQI6)+7*
sum
(DlReceivedCQI7)+8*
sum
(DlReceivedCQI8)+9*
sum
(DlReceivedCQI9)+10
*sum
(DlReceivedCQI10)+1
1*sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 330 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
edCQI2+DlRecei
vedCQI3+DlRec
eivedCQI4+DlRe
ceivedCQI5+DlR
eceivedCQI6+Dl
ReceivedCQI7+
DlReceivedCQI8
+DlReceivedCQI
9+DlReceivedC
QI10+DlReceive
dCQI11+DlRecei
vedCQI12+DlRe
ceivedCQI13+Dl
ReceivedCQI14+
DlReceivedCQI1
5)
(DlReceivedCQI11)+1
2*sum
(DlReceivedCQI12)+1
3*sum
(DlReceivedCQI13)+1
4*sum
(DlReceivedCQI14)+1
5*sum
(DlReceivedCQI15))/(
sum
(DlReceivedCQI0)+su
m
(DlReceivedCQI1)+su
m
(DlReceivedCQI2)+su
m
(DlReceivedCQI3)+su
m
(DlReceivedCQI4)+su
m
(DlReceivedCQI5)+su
m
(DlReceivedCQI6)+su
m
(DlReceivedCQI7)+su
m
(DlReceivedCQI8)+su
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 331 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
m
(DlReceivedCQI9)+su
m
(DlReceivedCQI10)+s
um
(DlReceivedCQI11)+s
um
(DlReceivedCQI12)+s
um
(DlReceivedCQI13)+s
um
(DlReceivedCQI14)+s
um
(DlReceivedCQI15))
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 332 of 427
2600-00FET7GAT 6.0
19.6 DL PMI
This section provides UE’s PMI report information.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlReceivedPMI0 count The number of times that PMI 0
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI1 count The number of times that PMI 1
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI2 count The number of times that PMI 2
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI3 count The number of times that PMI 3
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI4 count The number of times that PMI 4
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI5 count The number of times that PMI 5
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI6 count The number of times that PMI 6
is received
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 333 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlReceivedPMI7 count The number of times that PMI 7
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI8 count The number of times that PMI 8
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI9 count The number of times that PMI 9
is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI10 count The number of times that PMI
10 is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI11 count The number of times that PMI
11 is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI12 count The number of times that PMI
12 is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI13 count The number of times that PMI
13 is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI14 count The number of times that PMI
14 is received
Y CC 5.12 s. int 0-2147483647 - -
DlReceivedPMI15 count The number of times that PMI
15 is received
Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 334 of 427
2600-00FET7GAT 6.0
19.7 DL RI
This section provides UE’s RI report information.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
DlReceive
dRI0
count reserved Y CC 5.12 s. int 0-2147483647 - -
DlReceive
dRI1
count The number of times that RI 1 is
received
Y CC 5.12 s. int 0-2147483647 - -
DlReceive
dRI2
count The number of times that RI 2 is
received
Y CC 5.12 s. int 0-2147483647 - -
DlReceive
dRI3
count The number of times that RI 3 is
received
Y CC 5.12 s. int 0-2147483647 - -
DlReceive
dRI4
count The number of times that RI 4 is
received
Y CC 5.12 s. int 0-2147483647 - -
DlReceive
dRIAvg
RI Average value of DlReceivedRI Y OW Period float 0-4 (0*DlReceived
RI0+1*DlRecei
vedRI1+2*DlR
eceivedRI2+3*
(0*sum
(DlReceivedRI0)+1*sum
(DlReceivedRI1)+2*sum
(DlReceivedRI2)+3*sum
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 335 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
DlReceivedRI3
+4*DlReceived
RI4)/(DlReceiv
edRI0+DlRecei
vedRI1+DlRec
eivedRI2+DlRe
ceivedRI3+DlR
eceivedRI4)
(DlReceivedRI3)+4*sum
(DlReceivedRI4))/(sum
(DlReceivedRI0)+sum
(DlReceivedRI1)+sum
(DlReceivedRI2)+sum
(DlReceivedRI3)+sum
(DlReceivedRI4))
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 336 of 427
2600-00FET7GAT 6.0
19.8 DL ACK/NACK/DTX Ratio
This section provides UE’s ACK/NACK/DTX ratio information.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
DL Layer 1~4 Layer (data stream count)
1: 1 stream
2: 2 streams
3: 3 streams
4: 4 streams
Codeword 0~1 Codeword
Status 0~2 0: ACK, 1: NACK, 2: DTX
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
DlreceivedAckNa
ckDtxRatio
% ACK, NACK, DTX ratio Y SI 5.12 s. float 0-100 DlreceivedAckNackDtx
RatioTot/DlreceivedAck
NackDtxRatioCnt
sum
(DlreceivedAckNack
DtxRatioTot)/sum
(DlreceivedAckNack
DtxRatioCnt)
DlreceivedAckNa
ckDtxRatioTot
% Total ACK, NACK, and
DTX ratios
- SI 5.12 s float 0~3.4*10^38 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 337 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily,
Monthly Formula
DlreceivedAckNa
ckDtxRatioCnt
count Total ACK, NACK, and
DTX ratio count
- SI 5.12 s int 0~21474836
47
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 338 of 427
2600-00FET7GAT 6.0
20 IOT
20.1 Uplink IOT Level
This section provides statistics for 9 IoT levels.
The IoT dB value is divided into 10 levels for each PRB. The statistics levels are classified as follows.
Level 0: 0 <= IoT < 2 dB
Level 1: 2 <= IoT < 4 dB
…
Level 9: 18 <= IoT (count all that are equal to or greater than 18 dB)
Index
Name Range Description
cNum 0~2 Serving Cell Index
LEVEL 0~9 IOT Level
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB0 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB1 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB2 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB3 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB4 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 339 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB5 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB6 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB7 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB8 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB9 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB10 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB11 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB12 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB13 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB14 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB15 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB16 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB17 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB18 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB19 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB20 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB21 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB22 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB23 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB24 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB25 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB26 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 340 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB27 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB28 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB29 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB30 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB31 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB32 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB33 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB34 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB35 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB36 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB37 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB38 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB39 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB40 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB41 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB42 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB43 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB44 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB45 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB46 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB47 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB48 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 341 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB49 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB50 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB51 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB52 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB53 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB54 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB55 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB56 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB57 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB58 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB59 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB60 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB61 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB62 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB63 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB64 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB65 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB66 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB67 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB68 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB69 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB70 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 342 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB71 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB72 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB73 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB74 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB75 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB76 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB77 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB78 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB79 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB80 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB81 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB82 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB83 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB84 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB85 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB86 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB87 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB88 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB89 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB90 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB91 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB92 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 343 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PRB93 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB94 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB95 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB96 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB97 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB98 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
PRB99 count IOT level count for each PRB Y CC 5.12 s. int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 344 of 427
2600-00FET7GAT 6.0
21 MLBO
21.1 Load
This section provides statistics for mobility load balancing operation.
Index
Name Range Description
cNum 0~2 Serving Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
LoadIndicatorAvg % Average load of a cell when
overload occurs due to the
MLBO operation
Y GAUGE 5 s float 0-100 LoadIndicatorTot/
LoadIndicatorCnt
sum (LoadIndicatorTot)/
sum (LoadIndicatorCnt)
LoadIndicatorMin % Minimum load of a cell
when overload occurs due
to the MLBO operation
Y GAUGE 5 s float 0-100 - min (LoadIndicatorMin)
LoadIndicatorMax % Maximum load of a cell
when overload occurs due
to the MLBO operation
Y GAUGE 5 s float 0-100 - max
(LoadIndicatorMax)
LoadIndicatorTot % Accumulated load of a cell
when overload occurs due
to the MLBO operation
Y GAUGE 5 s float 0-100 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 345 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily, Monthly
Formula
LoadIndicatorCnt count The number of
LoadIndicatorAvg called
Y GAUGE 5 s int 0-2147483647 - -
OverloadCount count The number of overload
occurrences due to the
MLBO operation
Y CC 5 s int 0-2147483647 - -
MlbDurationAvg s Average of the overload
period due to the MLBO
operation
Y GAUGE 5 s float 0-100 MlbDurationTot/M
lbDurationCnt
sum (MlbDurationTot)/
sum (MlbDurationCnt)
MlbDurationMin s Minimum value of the
overload period due to the
MLBO operation
Y GAUGE 5 s float 0-100 - min (MlbDurationMin)
MlbDurationMax s Maximum value of the
overload period due to the
MLBO operation
Y GAUGE 5 s float 0-100 - max (MlbDurationMax)
MlbDurationTot s Accumulated value of the
overload period due to the
MLBO operation
Y GAUGE 5 s float 0-100 - -
MlbDurationCnt count The number of
MlbDurationAvg called
Y GAUGE 5 s int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 346 of 427
2600-00FET7GAT 6.0
21.2 Load Balancing Handover
This section provides statistics for handovers that are performed by SON load balancing.
Index
Name Range Description
cNum 0~2 Serving Cell Index
tcId 0~268435455 Target Cell Index
Step 1~3 Load Balancing Handover Triggering Step
1: LBHO within the same group & sector
2: LBHO between different groups but the same sector (the same eNB)
3: LBHO between different sectors
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
MlbNotTriggeredB
yLoadCondition
count The number of times when there is no
candidate neighbor cell that meets the
load condition although MLB is
triggered (collected only at Step 3)
Y CC event int 0-2147483647 - -
MlbNotTriggeredB
yRadioCondition
count The number of times when there is no
candidate UE because radio condition
is not met although MLB is triggered
(collected only at Step 3)
Y CC event int 0-2147483647 - -
MlbHOAtt count The number of handover attempts
when MLB is triggered
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 347 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
MlbHOSucc count The number of successful handovers
when MLB is triggered
Y CC event int 0-2147483647 - -
LbhoCnt count Load Balancing handover collection
count
- CC event int 0~2147483647 - -
LbhoCid tcID tcID of which collection is requested - OW event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 348 of 427
2600-00FET7GAT 6.0
22 Message
22.1 Protocol Message
This section provides statistics for (RRC/S1AP/X2AP) protocol messages transmitted/received by eNB.
Index
Name Range Description
PLMN 0~268435455 PLMN
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RrcMsgSnd count The number of times that the eNB transmits
an RRC protocol message
Y CC event int 0-2147483647 - -
RrcMsgRcv count The number of times that the eNB receives
an RRC protocol message
Y CC event int 0-2147483647 - -
S1MsgSnd count The number of times that the eNB transmits
an S1AP protocol message
Y CC event int 0-2147483647 - -
S1MsgRcv count The number of times that the eNB receives
an S1AP protocol message
Y CC event int 0-2147483647 - -
X2MsgSnd count The number of times that the eNB transmits
an X2AP protocol message
Y CC event int 0-2147483647 - -
X2MsgRcv count The number of times that the eNB receives
am X2AP protocol message
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 349 of 427
2600-00FET7GAT 6.0
22.2 RRC Message
Describes the RRC Message statistics transmitted/received by the eNB.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TotalRrc_Tx count Number of Total RRC Message
transmitted by the eNB
Y CC event int 0~2147483647 - -
TotalRrc_Rx count Number of Total RRC Message
received by the eNB
Y CC event int 0~2147483647 - -
RrcCounterChe
ck
count Number of RrcCounterCheck Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
RrcCounterChe
ckResponse
count Number of RrcCounterCheckResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcCSFBParam
etersRequestC
DMA2000
count Number of
RrcCSFBParametersRequestCDMA20
00 Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
RrcCSFBParam
etersResponse
CDMA2000
count Number of
RrcCSFBParametersResponseCDMA2
000 Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
RrcDLInformati
onTransfer
count Number of RrcDLInformationTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 350 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RrcHandoverFr
omEUTRAPrep
arationRequest
count Number of
RrcHandoverFromEUTRAPreparationR
equest Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
RrcMeasureme
ntReport
count Number of RrcMeasurementReport
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcMobilityFro
mEUTRAComm
and
count Number of
RrcMobilityFromEUTRACommand
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReconfigura
tion
count Number of
RrcRRCConnectionReconfiguration
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReconfigura
tionComplete
count Number of
RrcRRCConnectionReconfigurationCo
mplete Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReestablish
ment
count Number of
RrcRRCConnectionReestablishment
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReestablish
mentComplete
count Number of
RrcRRCConnectionReestablishmentCo
mplete Message transmitted/received
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 351 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
by the eNB
RrcRRCConnec
tionReestablish
mentReject
count Number of
RrcRRCConnectionReestablishmentRe
ject Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReestablish
mentRequest
count Number of
RrcRRCConnectionReestablishmentRe
quest Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionReject
count Number of RrcRRCConnectionReject
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionRelease
count Number of RrcRRCConnectionRelease
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionRequest
count Number of RrcRRCConnectionRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionSetup
count Number of RrcRRCConnectionSetup
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcRRCConnec
tionSetupCompl
ete
count Number of
RrcRRCConnectionSetupComplete
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 352 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RrcSecurityMod
eCommand
count Number of RrcSecurityModeCommand
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcSecurityMod
eComplete
count Number of RrcSecurityModeComplete
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcSecurityMod
eFailure
count Number of RrcSecurityModeFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcUECapabilit
yEnquiry
count Number of RrcUECapabilityEnquiry
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcUECapabilit
yInformation
count Number of RrcUECapabilityInformation
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcULHandover
PreparationTran
sfer
count Number of
RrcULHandoverPreparationTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcULInformati
onTransfer
count Number of RrcULInformationTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcUEInformati
onRequest
count Number of RrcUEInformationRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 353 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RrcUEInformati
onResponse
count Number of RrcUEInformationResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
RrcProximityInd
ication
count Number of RrcProximityIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 354 of 427
2600-00FET7GAT 6.0
22.3 S1AP Message
Describes the S1AP Message statistics transmitted/received from the eNB.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TotalS1ap_Tx count Number of Total S1AP Message
transmitted by the eNB
Y CC event int 0~2147483647 - -
TotalS1ap_Rx count Number of Total S1AP Message
received by the eNB
Y CC event int 0~2147483647 - -
S1apCellTraffic
Trace
count Number of S1apCellTrafficTrace
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apDeactivate
Trace
count Number of S1apDeactivateTrace
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apDownlinkN
ASTransport
count Number of
S1apDownlinkNASTransport Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apDownlinkS
cdma2000tunne
ling
count Number of
S1apDownlinkScdma2000tunneling
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apENBConfig
urationTransfer
count Number of
S1apENBConfigurationTransfer
Message transmitted/received by the
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 355 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
eNB
S1apENBConfig
urationUpdate
count Number of
S1apENBConfigurationUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apENBConfig
urationUpdateA
cknowledge
count Number of
S1apENBConfigurationUpdateAcknowl
edge Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
S1apENBConfig
urationUpdateF
ailure
count Number of
S1apENBConfigurationUpdateFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apENBDirectI
nformationTrans
fer
count Number of
S1apENBDirectInformationTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apENBStatus
Transfer
count Number of S1apENBStatusTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apERABModi
fyRequest
count Number of S1apERABModifyRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apERABModi
fyResponse
count Number of
S1apERABModifyResponse Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 356 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1apERABRele
aseCommand
count Number of
S1apERABReleaseCommand
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apERABRele
aseResponse
count Number of
S1apERABReleaseResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apERABRele
aseIndication
count Number of
S1apERABReleaseIndication Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apERABSetu
pRequest
count Number of S1apERABSetupRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apERABSetu
pResponse
count Number of S1apERABSetupResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apErrorIndica
tion
count Number of S1apErrorIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
Cancel
count Number of S1apHandoverCancel
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
CancelAcknowl
edge
count Number of
S1apHandoverCancelAcknowledge
Message transmitted/received by the
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 357 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
eNB
S1apHandover
Command
count Number of S1apHandoverCommand
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandoverF
ailure
count Number of S1apHandoverFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
Notify
count Number of S1apHandoverNotify
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandoverP
reparationFailur
e
count Number of
S1apHandoverPreparationFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
Request
count Number of S1apHandoverRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
RequestAcknow
ledge
count Number of
S1apHandoverRequestAcknowledge
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apHandover
Required
count Number of S1apHandoverRequired
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apInitialConte count Number of Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 358 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
xtSetupFailure S1apInitialContextSetupFailure
Message transmitted/received by the
eNB
S1apInitialConte
xtSetupRequest
count Number of
S1apInitialContextSetupRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apInitialConte
xtSetupRespons
e
count Number of
S1apInitialContextSetupResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apInitialUEM
essage
count Number of S1apInitialUEMessage
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apLocationR
eportingControl
count Number of
S1apLocationReportingControl
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apLocationR
eportFailureIndi
cation
count Number of
S1apLocationReportFailureIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apLocationR
eport
count Number of S1apLocationReport
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apMMEConfi count Number of Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 359 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
gurationTransfer S1apMMEConfigurationTransfer
Message transmitted/received by the
eNB
S1apMMEConfi
gurationUpdate
count Number of
S1apMMEConfigurationUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apMMEConfi
gurationUpdate
Acknowledge
count Number of
S1apMMEConfigurationUpdateAcknow
ledge Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
S1apMMEConfi
gurationUpdate
Failure
count Number of
S1apMMEConfigurationUpdateFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apMMEDirect
InformationTran
sfer
count Number of
S1apMMEDirectInformationTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apMMEStatu
sTransfer
count Number of S1apMMEStatusTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apNASNonD
eliveryIndication
count Number of
S1apNASNonDeliveryIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 360 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1apOverloadSt
art
count Number of S1apOverloadStart
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apOverloadSt
op
count Number of S1apOverloadStop
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apPaging count Number of S1apPaging Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apPathSwitch
Request
count Number of S1apPathSwitchRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apPathSwitch
RequestAcknow
ledge
count Number of
S1apPathSwitchRequestAcknowledge
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apPathSwitch
RequestFailure
count Number of
S1apPathSwitchRequestFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apReset count Number of S1apReset Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apResetAckn
owledge
count Number of S1apResetAcknowledge
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apSetupFailu count Number of S1apSetupFailure Message Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 361 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
re transmitted/received by the eNB
S1apSetupRequ
est
count Number of S1apSetupRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apSetupResp
onse
count Number of S1apSetupResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apTraceFailu
reIndication
count Number of S1apTraceFailureIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apTraceStart count Number of S1apTraceStart Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apUECapabili
tyInfoIndication
count Number of
S1apUECapabilityInfoIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUEContext
ModificationFail
ure
count Number of
S1apUEContextModificationFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUEContext
ModificationReq
uest
count Number of
S1apUEContextModificationRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUEContext count Number of Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 362 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ModificationRes
ponse
S1apUEContextModificationResponse
Message transmitted/received by the
eNB
S1apUEContext
ReleaseComma
nd
count Number of
S1apUEContextReleaseCommand
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUEContext
ReleaseComple
te
count Number of
S1apUEContextReleaseComplete
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUEContext
ReleaseRequest
count Number of
S1apUEContextReleaseRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUplinkNAS
Transport
count Number of S1apUplinkNASTransport
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apUplinkScd
ma2000tunneling
count Number of
S1apUplinkScdma2000tunneling
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apWriteRepla
ceWarningRequ
est
count Number of
S1apWriteReplaceWarningRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 363 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
S1apWriteRepla
ceWarningResp
onse
count Number of
S1apWriteReplaceWarningResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apKillRequest count Number of S1apKillRequest Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apKillRespon
se
count Number of S1apKillResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
S1apDownlinkU
EAssociatedLP
PaTransport
count Number of
S1apDownlinkUEAssociatedLPPaTran
sport Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
S1apUplinkUEA
ssociatedLPPaT
ransport
count Number of
S1apUplinkUEAssociatedLPPaTransp
ort Message transmitted/received by
the eNB
Y CC event int 0~2147483647 - -
S1apDownlinkN
onUEAssociate
dLPPaTransport
count Number of
S1apDownlinkNonUEAssociatedLPPa
Transport Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
S1apUplinkNon
UEAssociatedL
PPaTransport
count Number of
S1apUplinkNonUEAssociatedLPPaTra
nsport Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 364 of 427
2600-00FET7GAT 6.0
22.4 X2AP Message
Describes the X2AP Message statistics transmitted/received from the eNB.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
TotalX2ap_Tx count Number of Total X2AP Message
transmitted by the eNB
Y CC event int 0~2147483647 - -
TotalX2ap_Rx count Number of Total X2AP Message
received by the eNB
Y CC event int 0~2147483647 - -
Tx_X2apErrorIn
dication
count Number of Tx_X2apErrorIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apHando
verRequest
count Number of Tx_X2apHandoverRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apHando
verRequestAck
nowledge
count Number of
Tx_X2apHandoverRequestAcknowledg
e Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apHando
verPreparationF
ailure
count Number of
Tx_X2apHandoverPreparationFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 365 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Tx_X2apSNStat
usTransfer
count Number of Tx_X2apSNStatusTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apUECon
textRelease
count Number of Tx_X2apUEContextRelease
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apHando
verCancel
count Number of Tx_X2apHandoverCancel
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apLoadIn
formation
count Number of Tx_X2apLoadInformation
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apReset
Request
count Number of Tx_X2apResetRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apReset
Response
count Number of Tx_X2apResetResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apX2Set
upRequest
count Number of Tx_X2apX2SetupRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apX2Set
upResponse
count Number of Tx_X2apX2SetupResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 366 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Tx_X2apX2Set
upFailure
count Number of Tx_X2apX2SetupFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apENBC
onfigurationUpd
ate
count Number of
Tx_X2apENBConfigurationUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apENBC
onfigurationUpd
ateAcknowledg
e
count Number of
Tx_X2apENBConfigurationUpdateAckn
owledge Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
Tx_X2apENBC
onfigurationUpd
ateFailure
count Number of
Tx_X2apENBConfigurationUpdateFailur
e Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apResour
ceStatusReque
st
count Number of
Tx_X2apResourceStatusRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apResour
ceStatusRespo
nse
count Number of
Tx_X2apResourceStatusResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 367 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Tx_X2apResour
ceStatusFailure
count Number of
Tx_X2apResourceStatusFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apResour
ceStatusUpdate
count Number of
Tx_X2apResourceStatusUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apHando
verReport
count Number of Tx_X2apHandoverReport
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apMobilit
yChangeReque
st
count Number of
Tx_X2apMobilityChangeRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apMobilit
yChangeAckno
wledge
count Number of
Tx_X2apMobilityChangeAcknowledge
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apMobilit
yChangeFailure
count Number of
Tx_X2apMobilityChangeFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 368 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Tx_X2apCellAct
ivationRequest
count Number of
Tx_X2apCellActivationRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apCellActi
vationResponse
count Number of
Tx_X2apCellActivationResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Tx_X2apCellAct
ivationFailure
count Number of
Tx_X2apCellActivationFailure Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
Tx_X2apRadioL
inkFailureIndica
tion
count Number of
Tx_X2apRadioLinkFailureIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apErrorIn
dication
count Number of Rx_X2apErrorIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apHando
verRequest
count Number of Rx_X2apHandoverRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apHando
verRequestAck
nowledge
count Number of
Rx_X2apHandoverRequestAcknowledg
e Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 369 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Rx_X2apHando
verPreparationF
ailure
count Number of
Rx_X2apHandoverPreparationFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apSNStat
usTransfer
count Number of Rx_X2apSNStatusTransfer
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apUECo
ntextRelease
count Number of Rx_X2apUEContextRelease
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apHando
verCancel
count Number of Rx_X2apHandoverCancel
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apLoadIn
formation
count Number of Rx_X2apLoadInformation
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apReset
Request
count Number of Rx_X2apResetRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apReset
Response
count Number of Rx_X2apResetResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apX2Set
upRequest
count Number of Rx_X2apX2SetupRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 370 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Rx_X2apX2Set
upResponse
count Number of Rx_X2apX2SetupResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apX2Set
upFailure
count Number of Rx_X2apX2SetupFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apENBC
onfigurationUpd
ate
count Number of
Rx_X2apENBConfigurationUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apENBCo
nfigurationUpdat
eAcknowledge
count Number of
Rx_X2apENBConfigurationUpdateAckn
owledge Message transmitted/received
by the eNB
Y CC event int 0~2147483647 - -
Rx_X2apENBC
onfigurationUpd
ateFailure
count Number of
Rx_X2apENBConfigurationUpdateFailur
e Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apResou
rceStatusReque
st
count Number of
Rx_X2apResourceStatusRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apResou
rceStatusRespo
nse
count Number of
Rx_X2apResourceStatusResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 371 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Rx_X2apResou
rceStatusFailure
count Number of
Rx_X2apResourceStatusFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apResour
ceStatusUpdate
count Number of
Rx_X2apResourceStatusUpdate
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apHando
verReport
count Number of Rx_X2apHandoverReport
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apMobilit
yChangeReque
st
count Number of
Rx_X2apMobilityChangeRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apMobilit
yChangeAckno
wledge
count Number of
Rx_X2apMobilityChangeAcknowledge
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apMobilit
yChangeFailure
count Number of
Rx_X2apMobilityChangeFailure
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 372 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Rx_X2apCellAc
tivationRequest
count Number of
Rx_X2apCellActivationRequest
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apCellActi
vationResponse
count Number of
Rx_X2apCellActivationResponse
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Rx_X2apCellAc
tivationFailure
count Number of
Rx_X2apCellActivationFailure Message
transmitted/received by the eNB
Y CC event int 0~2147483647 - -
Rx_X2apRadio
LinkFailureIndic
ation
count Number of
Rx_X2apRadioLinkFailureIndication
Message transmitted/received by the
eNB
Y CC event int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 373 of 427
2600-00FET7GAT 6.0
23 Traffic OAM
23.1 Throughput Distribution
This section provides statistics for packet throughput distribution.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin1 count Number of uplink RBs with 0 Kbps ≤
throughput < 100 Kbps
Y CC event int 0-2147483647 - -
UlThruBin2 count Number of uplink RBs with 100 Kbps ≤
throughput < 200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin3 count Number of uplink RBs with 200 Kbps ≤
throughput < 300 Kbps
Y CC event int 0-2147483647 - -
UlThruBin4 count Number of uplink RBs with 300 Kbps ≤
throughput < 400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin5 count Number of uplink RBs with 400 Kbps ≤
throughput < 500 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 374 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin6 count Number of uplink RBs with 500 Kbps ≤
throughput < 600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin7 count Number of uplink RBs with 600 Kbps ≤
throughput < 700 Kbps
Y CC event int 0-2147483647 - -
UlThruBin8 count Number of uplink RBs with 700 Kbps ≤
throughput < 800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin9 count Number of uplink RBs with 800 Kbps ≤
throughput < 900 Kbps
Y CC event int 0-2147483647 - -
UlThruBin10 count Number of uplink RBs with 900 Kbps ≤
throughput < 1000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin11 count Number of uplink RBs with 1000 Kbps ≤
throughput < 1200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin12 count Number of uplink RBs with 1200 Kbps ≤
throughput < 1400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin13 count Number of uplink RBs with 1400 Kbps ≤
throughput < 1600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin14 count Number of uplink RBs with 1600 Kbps ≤
throughput < 1800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin15 count Number of uplink RBs with 1800 Kbps ≤
throughput < 2000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin16 count Number of uplink RBs with 2000 Kbps ≤
throughput < 2200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin17 count Number of uplink RBs with 22000 Kbps ≤
throughput < 2400 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 375 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin18 count Number of uplink RBs with 2400 Kbps ≤
throughput < 2600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin19 count Number of uplink RBs with 2600 Kbps ≤
throughput < 2800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin20 count Number of uplink RBs with 2800 Kbps ≤
throughput < 3000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin21 count Number of uplink RBs with 3000 Kbps ≤
throughput < 3400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin22 count Number of uplink RBs with 3400 Kbps ≤
throughput < 3800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin23 count Number of uplink RBs with 3800 Kbps ≤
throughput < 4200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin24 count Number of uplink RBs with 4200 Kbps ≤
throughput < 4600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin25 count Number of uplink RBs with 4600 Kbps ≤
throughput < 5000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin26 count Number of uplink RBs with 5000 Kbps ≤
throughput < 5400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin27 count Number of uplink RBs with 5400 Kbps ≤
throughput < 5800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin28 count Number of uplink RBs with 5800 Kbps ≤
throughput < 6200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin29 count Number of uplink RBs with 6200 Kbps ≤
throughput < 6600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 376 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin30 count Number of uplink RBs with 6600 Kbps ≤
throughput < 7000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin31 count Number of uplink RBs with 7000 Kbps ≤
throughput < 7800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin32 count Number of uplink RBs with 7800 Kbps ≤
throughput < 8600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin33 count Number of uplink RBs with 8600 Kbps ≤
throughput < 9400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin34 count Number of uplink RBs with 9400 Kbps ≤
throughput < 10200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin35 count Number of uplink RBs with 10200 Kbps ≤
throughput < 11000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin36 count Number of uplink RBs with 11000 Kbps ≤
throughput < 11800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin37 count Number of uplink RBs with 11800 Kbps ≤
throughput < 12600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin38 count Number of uplink RBs with 12600 Kbps ≤
throughput < 13400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin39 count Number of uplink RBs with 13400 Kbps ≤
throughput < 14200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin40 count Number of uplink RBs with 14200 Kbps ≤
throughput < 15000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin41 count Number of uplink RBs with 15000 Kbps ≤
throughput < 16600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 377 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin42 count Number of uplink RBs with 16600 Kbps ≤
throughput < 18200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin43 count Number of uplink RBs with 18200 Kbps ≤
throughput < 19800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin44 count Number of uplink RBs with 19800 Kbps ≤
throughput < 21400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin45 count Number of uplink RBs with 21400 Kbps ≤
throughput < 23000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin46 count Number of uplink RBs with 23000 Kbps ≤
throughput < 24600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin47 count Number of uplink RBs with 24600 Kbps ≤
throughput < 26200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin48 count Number of uplink RBs with 26200 Kbps ≤
throughput < 27800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin49 count Number of uplink RBs with 27800 Kbps ≤
throughput < 29400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin50 count Number of uplink RBs with 29400 Kbps ≤
throughput < 31000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin51 count Number of uplink RBs with 31000 Kbps ≤
throughput < 34200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin52 count Number of uplink RBs with 34200 Kbps ≤
throughput < 37400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin53 count Number of uplink RBs with 37400 Kbps ≤
throughput < 40600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 378 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin54 count Number of uplink RBs with 40600 Kbps ≤
throughput < 43800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin55 count Number of uplink RBs with 43800 Kbps ≤
throughput < 47000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin56 count Number of uplink RBs with 47000 Kbps ≤
throughput < 50200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin57 count Number of uplink RBs with 50200 Kbps ≤
throughput < 53400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin58 count Number of uplink RBs with 53400 Kbps ≤
throughput < 56600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin59 count Number of uplink RBs with 56600 Kbps ≤
throughput < 59800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin60 count Number of uplink RBs with 59800 Kbps ≤
throughput < 63000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin61 count Number of uplink RBs with 63000 Kbps ≤
throughput < 69400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin62 count Number of uplink RBs with 69400 Kbps ≤
throughput < 75800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin63 count Number of uplink RBs with 75800 Kbps ≤
throughput < 82200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin64 count Number of uplink RBs with 82200 Kbps ≤
throughput < 88600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin65 count Number of uplink RBs with 88600 Kbps ≤
throughput < 95000 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 379 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin66 count Number of uplink RBs with 95000 Kbps ≤
throughput < 101400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin67 count Number of uplink RBs with 101400 Kbps ≤
throughput < 107800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin68 count Number of uplink RBs with 107800 Kbps ≤
throughput < 114200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin69 count Number of uplink RBs with 114200 Kbps ≤
throughput < 120600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin70 count Number of uplink RBs with 120600 Kbps ≤
throughput < 127000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin71 count Number of uplink RBs with 127000 Kbps ≤
throughput < 139800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin72 count Number of uplink RBs with 139800 Kbps ≤
throughput < 152600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin73 count Number of uplink RBs with 152600 Kbps ≤
throughput < 165400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin74 count Number of uplink RBs with 165400 Kbps ≤
throughput < 178200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin75 count Number of uplink RBs with 178200 Kbps ≤
throughput < 191000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin76 count Number of uplink RBs with 191000 Kbps ≤
throughput < 203800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin77 count Number of uplink RBs with 203800 Kbps ≤
throughput < 216600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 380 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin78 count Number of uplink RBs with 216600 Kbps ≤
throughput < 229400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin79 count Number of uplink RBs with 229400 Kbps ≤
throughput < 242200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin80 count Number of uplink RBs with 242200 Kbps ≤
throughput < 255000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin81 count Number of uplink RBs with 255000 Kbps ≤
throughput < 280600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin82 count Number of uplink RBs with 280600 Kbps ≤
throughput < 306200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin83 count Number of uplink RBs with 306200 Kbps ≤
throughput < 331800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin84 count Number of uplink RBs with 331800 Kbps ≤
throughput < 357400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin85 count Number of uplink RBs with 357400 Kbps ≤
throughput < 383000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin86 count Number of uplink RBs with 383000 Kbps ≤
throughput < 408600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin87 count Number of uplink RBs with 408600 Kbps ≤
throughput < 434200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin88 count Number of uplink RBs with 434200 Kbps ≤
throughput < 459800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin89 count Number of uplink RBs with 459800 Kbps ≤
throughput < 485400 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 381 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UlThruBin90 count Number of uplink RBs with 485400 Kbps ≤
throughput < 511000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin91 count Number of uplink RBs with 511000 Kbps ≤
throughput < 562200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin92 count Number of uplink RBs with 562200 Kbps ≤
throughput < 613400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin93 count Number of uplink RBs with 613400 Kbps ≤
throughput < 664600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin94 count Number of uplink RBs with 664600 Kbps ≤
throughput < 715800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin95 count Number of uplink RBs with 715800 Kbps ≤
throughput < 767000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin96 count Number of uplink RBs with 767000 Kbps ≤
throughput < 818200 Kbps
Y CC event int 0-2147483647 - -
UlThruBin97 count Number of uplink RBs with 818200 Kbps ≤
throughput < 869400 Kbps
Y CC event int 0-2147483647 - -
UlThruBin98 count Number of uplink RBs with 869400 Kbps ≤
throughput < 920600 Kbps
Y CC event int 0-2147483647 - -
UlThruBin99 count Number of uplink RBs with 920600 Kbps ≤
throughput < 971800 Kbps
Y CC event int 0-2147483647 - -
UlThruBin100 count Number of uplink RBs with 971800 Kbps ≤
throughput < 1023000 Kbps
Y CC event int 0-2147483647 - -
UlThruBin101 count Number of uplink RBs with throughput ≥
1023000 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 382 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin1 count Number of downlink RBs with 0 Kbps ≤
throughput < 100 Kbps
Y CC event int 0-2147483647 - -
DlThruBin2 count Number of downlink RBs with 100 Kbps ≤
throughput < 200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin3 count Number of downlink RBs with 200 Kbps ≤
throughput < 300 Kbps
Y CC event int 0-2147483647 - -
DlThruBin4 count Number of downlink RBs with 300 Kbps ≤
throughput < 400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin5 count Number of downlink RBs with 400 Kbps ≤
throughput < 500 Kbps
Y CC event int 0-2147483647 - -
DlThruBin6 count Number of downlink RBs with 500 Kbps ≤
throughput < 600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin7 count Number of downlink RBs with 600 Kbps ≤
throughput < 700 Kbps
Y CC event int 0-2147483647 - -
DlThruBin8 count Number of downlink RBs with 700 Kbps ≤
throughput < 800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin9 count Number of downlink RBs with 800 Kbps ≤
throughput < 900 Kbps
Y CC event int 0-2147483647 - -
DlThruBin10 count Number of downlink RBs with 900 Kbps ≤
throughput < 1000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin11 count Number of downlink RBs with 1000 Kbps ≤
throughput < 1200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin12 count Number of downlink RBs with 1200 Kbps ≤
throughput < 1400 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 383 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin13 count Number of downlink RBs with 1400 Kbps ≤
throughput < 1600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin14 count Number of downlink RBs with 1600 Kbps ≤
throughput < 1800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin15 count Number of downlink RBs with 1800 Kbps ≤
throughput < 2000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin16 count Number of downlink RBs with 2000 Kbps ≤
throughput < 2200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin17 count Number of downlink RBs with 2200 Kbps ≤
throughput < 2400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin18 count Number of downlink RBs with 2400 Kbps ≤
throughput < 2600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin19 count Number of downlink RBs with 2600 Kbps ≤
throughput < 2800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin20 count Number of downlink RBs with 2800 Kbps ≤
throughput < 3000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin21 count Number of downlink RBs with 3000 Kbps ≤
throughput < 3400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin22 count Number of downlink RBs with 3400 Kbps ≤
throughput < 3800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin23 count Number of downlink RBs with 3800 Kbps ≤
throughput < 4200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin24 count Number of downlink RBs with 4200 Kbps ≤
throughput < 4600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 384 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin25 count Number of downlink RBs with 4600 Kbps ≤
throughput < 5000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin26 count Number of downlink RBs with 5000 Kbps ≤
throughput < 5400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin27 count Number of downlink RBs with 5400 Kbps ≤
throughput < 5800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin28 count Number of downlink RBs with 5800 Kbps ≤
throughput < 6200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin29 count Number of downlink RBs with 6200 Kbps ≤
throughput < 6600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin30 count Number of downlink RBs with 6600 Kbps ≤
throughput < 7000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin31 count Number of downlink RBs with 7000 Kbps ≤
throughput < 7800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin32 count Number of downlink RBs with 7800 Kbps ≤
throughput < 8600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin33 count Number of downlink RBs with 8600 Kbps ≤
throughput < 9400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin34 count Number of downlink RBs with 9400 Kbps ≤
throughput < 10200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin35 count Number of downlink RBs with 10200 Kbps
≤ throughput < 11000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin36 count Number of downlink RBs with 11000 Kbps
≤ throughput < 11800 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 385 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin37 count Number of downlink RBs with 11800 Kbps
≤ throughput < 12600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin38 count Number of downlink RBs with 12600 Kbps
≤ throughput < 13400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin39 count Number of downlink RBs with 13400 Kbps
≤ throughput < 14200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin40 count Number of downlink RBs with 14200 Kbps
≤ throughput < 15000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin41 count Number of downlink RBs with 15000 Kbps
≤ throughput < 16600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin42 count Number of downlink RBs with 16600 Kbps
≤ throughput < 18200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin43 count Number of downlink RBs with 18200 Kbps
≤ throughput < 19800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin44 count Number of downlink RBs with 19800 Kbps
≤ throughput < 21400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin45 count Number of downlink RBs with 21400 Kbps
≤ throughput < 23000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin46 count Number of downlink RBs with 23000 Kbps
≤ throughput < 24600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin47 count Number of downlink RBs with 24600 Kbps
≤ throughput < 26200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin48 count Number of downlink RBs with 26200 Kbps
≤ throughput < 27800 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 386 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin49 count Number of downlink RBs with 27800 Kbps
≤ throughput < 29400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin50 count Number of downlink RBs with 29400 Kbps
≤ throughput < 31000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin51 count Number of downlink RBs with 31000 Kbps
≤ throughput < 34200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin52 count Number of downlink RBs with 34200 Kbps
≤ throughput < 37400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin53 count Number of downlink RBs with 37400 Kbps
≤ throughput < 40600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin54 count Number of downlink RBs with 40600 Kbps
≤ throughput < 43800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin55 count Number of downlink RBs with 43800 Kbps
≤ throughput < 47000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin56 count Number of downlink RBs with 47000 Kbps
≤ throughput < 50200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin57 count Number of downlink RBs with 50200 Kbps
≤ throughput < 53400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin58 count Number of downlink RBs with 53400 Kbps
≤ throughput < 56600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin59 count Number of downlink RBs with 56600 Kbps
≤ throughput < 59800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin60 count Number of downlink RBs with 59800 Kbps
≤ throughput < 63000 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 387 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin61 count Number of downlink RBs with 63000 Kbps
≤ throughput < 69400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin62 count Number of downlink RBs with 69400 Kbps
≤ throughput < 75800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin63 count Number of downlink RBs with 75800 Kbps
≤ throughput < 82200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin64 count Number of downlink RBs with 82200 Kbps
≤ throughput < 88600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin65 count Number of downlink RBs with 88600 Kbps
≤ throughput < 95000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin66 count Number of downlink RBs with 95000 Kbps
≤ throughput < 101400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin67 count Number of downlink RBs with 101400 Kbps
≤ throughput < 107800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin68 count Number of downlink RBs with 107800 Kbps
≤ throughput < 114200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin69 count Number of downlink RBs with 114200 Kbps
≤ throughput < 120600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin70 count Number of downlink RBs with 120600 Kbps
≤ throughput < 127000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin71 count Number of downlink RBs with 127000 Kbps
≤ throughput < 139800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin72 count Number of downlink RBs with 139800 Kbps
≤ throughput < 152600 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 388 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin73 count Number of downlink RBs with 152600 Kbps
≤ throughput < 165400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin74 count Number of downlink RBs with 165400 Kbps
≤ throughput < 178200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin75 count Number of downlink RBs with 178200 Kbps
≤ throughput < 191000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin76 count Number of downlink RBs with 191000 Kbps
≤ throughput < 203800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin77 count Number of downlink RBs with 203800 Kbps
≤ throughput < 216600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin78 count Number of downlink RBs with 216600 Kbps
≤ throughput < 229400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin79 count Number of downlink RBs with 229400 Kbps
≤ throughput < 242200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin80 count Number of downlink RBs with 242200 Kbps
≤ throughput < 255000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin81 count Number of downlink RBs with 255000 Kbps
≤ throughput < 280600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin82 count Number of downlink RBs with 280600 Kbps
≤ throughput < 306200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin83 count Number of downlink RBs with 306200 Kbps
≤ throughput < 331800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin84 count Number of downlink RBs with 331800 Kbps
≤ throughput < 357400 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 389 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin85 count Number of downlink RBs with 357400 Kbps
≤ throughput < 383000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin86 count Number of downlink RBs with 383000 Kbps
≤ throughput < 408600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin87 count Number of downlink RBs with 408600 Kbps
≤ throughput < 434200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin88 count Number of downlink RBs with 434200 Kbps
≤ throughput < 459800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin89 count Number of downlink RBs with 459800 Kbps
≤ throughput < 485400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin90 count Number of downlink RBs with 485400 Kbps
≤ throughput < 511000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin91 count Number of downlink RBs with 511000 Kbps
≤ throughput < 562200 Kbps
Y CC event int 0-2147483647 - -
DlThruBin92 count Number of downlink RBs with 562200 Kbps
≤ throughput < 613400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin93 count Number of downlink RBs with 613400 Kbps
≤ throughput < 664600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin94 count Number of downlink RBs with 664600 Kbps
≤ throughput < 715800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin95 count Number of downlink RBs with 715800 Kbps
≤ throughput < 767000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin96 count Number of downlink RBs with 767000 Kbps
≤ throughput < 818200 Kbps
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 390 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruBin97 count Number of downlink RBs with 818200 Kbps
≤ throughput < 869400 Kbps
Y CC event int 0-2147483647 - -
DlThruBin98 count Number of downlink RBs with 869400 Kbps
≤ throughput < 920600 Kbps
Y CC event int 0-2147483647 - -
DlThruBin99 count Number of downlink RBs with 920600 Kbps
≤ throughput < 971800 Kbps
Y CC event int 0-2147483647 - -
DlThruBin100 count Number of downlink RBs with 971800 Kbps
≤ throughput < 1023000 Kbps
Y CC event int 0-2147483647 - -
DlThruBin101 count Number of downlink RBs with throughput ≥
1023000 Kbps
Y CC event int 0-2147483647 - -
UlThruAvg Kbps Average of the user uplink throughputs Y GAUGE event int 0-2147483647 UlThruTot/U
lThruCnt
sum (UlThruTot)/
sum (UlThruCnt)
UlThruMax Kbps Maximum value of the user uplink
throughput
Y GAUGE event int 0-2147483647 - max (UlThruMax)
UlThruMin Kbps Minimum value of the user uplink
throughput
Y GAUGE event int 0-2147483647 - min (UlThruMin)
UlThruTot Kbps Sum of the user uplink throughputs
collected
Y GAUGE event int 0-2147483647 - -
UlThruCnt count Number of user uplink throughput
collections
Y GAUGE event int 0-2147483647 - -
DlThruAvg Kbps Average of the user downlink throughputs Y GAUGE event int 0-2147483647 DlThruTot/D
lThruCnt
sum (DlThruTot)/
sum (DlThruCnt)
DlThruMax Kbps Maximum value of the user downlink
throughputs
Y GAUGE event int 0-2147483647 - max (DlThruMax)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 391 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
DlThruMin Kbps Minimum value of the user downlink
throughputs
Y GAUGE event int 0-2147483647 - min (DlThruMin)
DlThruTot Kbps Sum of the user downlink throughputs
collected
Y GAUGE event int 0-2147483647 - -
DlThruCnt count Number of user downlink throughput
collections
Y GAUGE event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 392 of 427
2600-00FET7GAT 6.0
23.2 Delay Distribution
This section provides statistics for packet delay distribution.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin1 count Number of downlink RBs with 0 ms ≤
delay < 10 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin2 count Number of downlink RBs with 10 ms ≤
delay < 20 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin3 count Number of downlink RBs with 20 ms ≤
delay < 30 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin4 count Number of downlink RBs with 30 ms ≤
delay < 40 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin5 count Number of downlink RBs with 40 ms ≤
delay < 50 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin6 count Number of downlink RBs with 50 ms ≤
delay < 60 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 393 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin7 count Number of downlink RBs with 60 ms ≤
delay < 70 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin8 count Number of downlink RBs with 70 ms ≤
delay < 80 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin9 count Number of downlink RBs with 80 ms ≤
delay < 90 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin10 count Number of downlink RBs with 90 ms ≤
delay < 100 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin11 count Number of downlink RBs with 100 ms
≤ delay < 110 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin12 count Number of downlink RBs with 110 ms
≤ delay < 120 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin13 count Number of downlink RBs with 120 ms
≤ delay < 130 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin14 count Number of downlink RBs with 130 ms
≤ delay < 140 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin15 count Number of downlink RBs with 140 ms
≤ delay < 150 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin16 count Number of downlink RBs with 150 ms
≤ delay < 160 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin17 count Number of downlink RBs with 160 ms
≤ delay < 170 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin18 count Number of downlink RBs with 170 ms
≤ delay < 180 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 394 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin19 count Number of downlink RBs with 180 ms
≤ delay < 190 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin20 count Number of downlink RBs with 190 ms
≤ delay < 200 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin21 count Number of downlink RBs with 200 ms
≤ delay < 210 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin22 count Number of downlink RBs with 210 ms
≤ delay < 220 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin23 count Number of downlink RBs with 220 ms
≤ delay < 230 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin24 count Number of downlink RBs with 230 ms
≤ delay < 240 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin25 count Number of downlink RBs with 240 ms
≤ delay < 250 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin26 count Number of downlink RBs with 250 ms
≤ delay < 260 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin27 count Number of downlink RBs with 260 ms
≤ delay < 270 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin28 count Number of downlink RBs with 270 ms
≤ delay < 280 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin29 count Number of downlink RBs with 280 ms
≤ delay < 290 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin30 count Number of downlink RBs with 290 ms
≤ delay < 300 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 395 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin31 count Number of downlink RBs with 300 ms
≤ delay < 320 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin32 count Number of downlink RBs with 320 ms
≤ delay < 340 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin33 count Number of downlink RBs with 340 ms
≤ delay < 360 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin34 count Number of downlink RBs with 360 ms
≤ delay < 380 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin35 count Number of downlink RBs with 380 ms
≤ delay < 400 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin36 count Number of downlink RBs with 400 ms
≤ delay < 420 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin37 count Number of downlink RBs with 420 ms
≤ delay < 440 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin38 count Number of downlink RBs with 440 ms
≤ delay < 460 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin39 count Number of downlink RBs with 460 ms
≤ delay < 480 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin40 count Number of downlink RBs with 480 ms
≤ delay < 500 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin41 count Number of downlink RBs with 500 ms
≤ delay < 550 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin42 count Number of downlink RBs with 550 ms
≤ delay < 600 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 396 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin43 count Number of downlink RBs with 600 ms
≤ delay < 650 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin44 count Number of downlink RBs with 650 ms
≤ delay < 700 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin45 count Number of downlink RBs with 700 ms
≤ delay < 750 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin46 count Number of downlink RBs with 750 ms
≤ delay < 800 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin47 count Number of downlink RBs with 800 ms
≤ delay < 850 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin48 count Number of downlink RBs with 850 ms
≤ delay < 900 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin49 count Number of downlink RBs with 900 ms
≤ delay < 950 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin50 count Number of downlink RBs with 950 ms
≤ delay < 1000 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin51 count Number of downlink RBs with 1000 ms
≤ delay < 1100 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin52 count Number of downlink RBs with 1100 ms
≤ delay < 1200 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin53 count Number of downlink RBs with 1200 ms
≤ delay < 1300 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin54 count Number of downlink RBs with 1300 ms
≤ delay < 1400 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 397 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin55 count Number of downlink RBs with 1400 ms
≤ delay < 1500 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin56 count Number of downlink RBs with 1500 ms
≤ delay < 1600 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin57 count Number of downlink RBs with 1600 ms
≤ delay < 1700 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin58 count Number of downlink RBs with 1700 ms
≤ delay < 1800 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin59 count Number of downlink RBs with 1800 ms
≤ delay < 1900 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin60 count Number of downlink RBs with 1900 ms
≤ delay < 2000 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin61 count Number of downlink RBs with 2000 ms
≤ delay < 2100 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin62 count Number of downlink RBs with 2100 ms
≤ delay < 2200 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin63 count Number of downlink RBs with 2200 ms
≤ delay < 2300 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin64 count Number of downlink RBs with 2300 ms
≤ delay < 2400 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin65 count Number of downlink RBs with 2400 ms
≤ delay < 2500 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin66 count Number of downlink RBs with 2500 ms
≤ delay < 2600 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 398 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
RlcDlDelayBin67 count Number of downlink RBs with 2600 ms
≤ delay < 2700 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin68 count Number of downlink RBs with 2700 ms
≤ delay < 2800 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin69 count Number of downlink RBs with 2800 ms
≤ delay < 2900 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin70 count Number of downlink RBs with 2900 ms
≤ delay < 3000 ms
Y CC event int 0-2147483647 - -
RlcDlDelayBin71 count Number of downlink RBs with delay ≥
3000 ms
Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 399 of 427
2600-00FET7GAT 6.0
23.3 Drop Distribution
This section provides statistics for packet drop and loss distribution.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpSduDropRat
eDlBin1
count Number of downlink RBs with SDU packet
drop rate ≤ 0 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin2
count Number of downlink RBs with 0 ppm
<SDU packet drop rate ≤ 1 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin3
count Number of downlink RBs with 1 ppm
<SDU packet drop rate ≤ 10 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin4
count Number of downlink RBs with 10 ppm
<SDU packet drop rate ≤ 100 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin5
count Number of downlink RBs with 100 ppm
<SDU packet drop rate ≤ 1000 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin6
count Number of downlink RBs with 1000 ppm
<SDU packet drop rate ≤ 10000 ppm
Y CC event int 0-2147483
647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 400 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpSduDropRat
eDlBin7
count Number of downlink RBs with 10000 ppm
<SDU packet drop rate ≤ 100000 ppm
Y CC event int 0-2147483
647
- -
PdcpSduDropRat
eDlBin8
count Number of downlink RBs with 100000 ppm
<SDU packet drop rate ≤ 1000000 ppm
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin1
count Number of downlink RBs with PDU packet
drop rate ≤ 0
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin2
count Number of downlink RBs with 0 < PDU
packet drop rate ≤ 0.000001
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin3
count Number of downlink RBs with 0.000001 <
PDU packet drop rate ≤ 0.00001
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin4
count Number of downlink RBs with 0.00001 <
PDU packet drop rate ≤ 0.0001
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin5
count Number of downlink RBs with 0.0001
<PDU packet drop rate ≤ 0.001
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin6
count Number of downlink RBs with 0.001 <
PDU packet drop rate ≤ 0.01
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin7
count Number of downlink RBs with 0.01 < PDU
packet drop rate ≤ 0.1
Y CC event int 0-2147483
647
- -
RlcSduDropRate
DlBin8
count Number of downlink RBs with 0.1 < PDU
packet drop rate ≤ 1
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin1
count Number of uplink RBs with SDU packet
loss rate ≤ 0 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin2
count Number of uplink RBs with 0 ppm < SDU
packet loss rate ≤ 1 ppm
Y CC event int 0-2147483
647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 401 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
PdcpSduLossRat
eUlBin3
count Number of uplink RBs with 1 ppm < SDU
packet loss rate ≤ 10 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin4
count Number of uplink RBs with 10 ppm < SDU
packet loss rate ≤ 100 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin5
count Number of uplink RBs with 100 ppm <
SDU packet loss rate ≤ 1000 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin6
count Number of uplink RBs with 1000 ppm <
SDU packet loss rate ≤ 10000 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin7
count Number of uplink RBs with 10000 ppm <
SDU packet loss rate ≤ 100000 ppm
Y CC event int 0-2147483
647
- -
PdcpSduLossRat
eUlBin8
count Number of uplink RBs with 100000 ppm <
SDU packet loss rate ≤ 1000000 ppm
Y CC event int 0-2147483
647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 402 of 427
2600-00FET7GAT 6.0
23.4 CQI Distribution
This section provides statistics for CQI distribution.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CqiBin1 count Number of RBs that use CQI 1 Y CC event int 0-2147483647 - -
CqiBin2 count Number of RBs that use CQI 2 Y CC event int 0-2147483647 - -
CqiBin3 count Number of RBs that use CQI 3 Y CC event int 0-2147483647 - -
CqiBin4 count Number of RBs that use CQI 4 Y CC event int 0-2147483647 - -
CqiBin5 count Number of RBs that use CQI 5 Y CC event int 0-2147483647 - -
CqiBin6 count Number of RBs that use CQI 6 Y CC event int 0-2147483647 - -
CqiBin7 count Number of RBs that use CQI 7 Y CC event int 0-2147483647 - -
CqiBin8 count Number of RBs that use CQI 8 Y CC event int 0-2147483647 - -
CqiBin9 count Number of RBs that use CQI 9 Y CC event int 0-2147483647 - -
CqiBin10 count Number of RBs that use CQI 10 Y CC event int 0-2147483647 - -
CqiBin11 count Number of RBs that use CQI 11 Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 403 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
CqiBin12 count Number of RBs that use CQI 12 Y CC event int 0-2147483647 - -
CqiBin13 count Number of RBs that use CQI 13 Y CC event int 0-2147483647 - -
CqiBin14 count Number of RBs that use CQI 14 Y CC event int 0-2147483647 - -
CqiBin15 count Number of RBs that use CQI 15 Y CC event int 0-2147483647 - -
CqiBin16 count Number of RBs that use CQI 16 Y CC event int 0-2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 404 of 427
2600-00FET7GAT 6.0
24 KPI This section calculates the KPI defined as per 3GPP 32.450 and provides to the EMS.
24.1 ACCESSIBILITY
A KPI that shows probability for an end-user to be provided with an E-RAB at request.
Probability success rate for E-RABs establishment. Successful attempts compared with total number of attempts for the different parts o
f the E-RAB establishment.
100
QCI.tEstabInitSAEB.NbrAt
QCIt.ccEstabIniSAEB.NbrSu
EstabAttS1SIG.Conn
EstabSuccS1SIG.Conn
causenEstab.RRC.AttCon
causennEstab.RRC.SuccCo
1
QCI
cause
QCI
cause
BEstabSRInitialEPSA
100
QCItEstabAdd.SAEB.NbrAt
QCI.ccEstabAddSAEB.NbrSu
2
QCI
QCI
stabSRAddedEPSBEA
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 405 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula Hourly, Daily, Monthly Formula
ErabAccessibili
tyInit
% Initial E-RAB
establishment success
rate. E-RAB
success/ERAB attempt
Y OW Period float 0-100 (sumRrc_ConnEs
tabSucc/sumRrc_
ConnEstabAtt)*(s
umS1sig_S1Con
nEstabSucc/sum
S1sig_S1ConnEs
tabAtt)*(sumErab
_EstabInitSuccNb
r/sumErab_EstabI
nitAttNbr)*100
(sum
(sumRrc_ConnEstabSucc)/sum
(sumRrc_ConnEstabAtt))*(sum
(sumS1sig_S1ConnEstabSucc)/
sum
(sumS1sig_S1ConnEstabAtt))*
(sum
(sumErab_EstabInitSuccNbr)/
sum
(sumErab_EstabInitAttNbr))*100
sumRrc_Conn
EstabSucc
count Total RRC ESTAB
success count
- OW Period int 0~214748
3647
- -
sumRrc_Conn
EstabAtt
count Total RRC ESTAB
attempt count
- OW Period int 0~214748
3647
- -
sumS1sig_S1C
onnEstabSucc
count Total UE Logical S1
Connection Setup
success count
- OW Period int 0~214748
3647
- -
sumS1sig_S1C
onnEstabAtt
count Total UE Logical S1
Connection Setup
attempt count
- OW Period int 0~214748
3647
- -
sumErab_Esta
bInitSuccNbr
count Total ERAB setup
success count
- OW Period int 0~214748
3647
- -
sumErab_Esta
bInitAttNbr
count Total ERAB setup
attempt count
- OW Period int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 406 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula Hourly, Daily, Monthly Formula
ErabAccessibili
tyAdd
% Added E-RAB
establishment success
rate Added E-RAN
success/Added ERAB
attempt
- OW Period float 0-100 (sumErab_Estab
AddSuccNbr/sum
Erab_EstabAddAt
tNbr)*100
(sum
(sumErab_EstabAddSuccNbr)/
sum
(sumErab_EstabAddAttNbr))*100
sumErab_Esta
bAddSuccNbr
count Total ERAB additional
setup success count
- OW Period int 0~214748
3647
- -
sumErab_Esta
bAddAttNbr
count Total ERAB additional
setup attempt count
- OW Period int 0~214748
3647
- -
ErabConnectio
nFailureRate
% Probability that an end-
user is not provided
with an E-RAB at the
initial request
- OW Period float 0-100 100-
ErabAccessibilityI
nit
if ((sum
(sumRrc_ConnEstabAtt)=0), 0, if
((sum
(sumS1sig_S1ConnEstabAtt)=0),
0, if ((sum
(sumErab_EstabInitAttNbr)=
0), 0, 100-ErabAccessibilityInit)))
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 407 of 427
2600-00FET7GAT 6.0
24.2 RETAINABILITY
A measurement that shows how often an end-user abnormally looses an E-RAB during the time the E-RAB is used.
This statistics item is collected for each cell.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ErabRetainab
ility
% Number of E-RABs with data
in a buffer that was
abnormally released
Y OW Period float 0-3.4*10^38 sumRelActive/
RetainSession
TimeUE*100
sum (sumRelActive)/
sum
(RetainSessionTimeU
E)*100
sumRelActive count Total count of bearers among
active E-RABs where a call is
released due to abnormal
operation in eNB
- OW Period int 0 ~ 2147483647 - -
RetainSessio
nTimeUE
ms Total in-session time of the
UE
- OW Period float 0~60*Period*1000 - -
eUESessionTimSAEB
QCIlActSAEB
RQCI
.
.Re.
2
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 408 of 427
2600-00FET7GAT 6.0
24.3 RETAINABILITY (QCI)
A measurement that shows how often an end-user abnormally looses an E-RAB during the time the E-RAB is used.
This statistics item is collected for each QCI.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
Erab_Retaina
bility
% Number of E-RABs with data in a buffer
that was abnormally released
Y OW Period float 0~3.4*10^
38
Retain_RelActive
/Retain_Session
TimeQCI * 100
sum (Retain_
RelActive)/sum
(Retain_SessionTi
meQCI) * 100
Retain_RelActi
ve
count Total count of bearers among active E-
RABs where a call is released due to
abnormal operation in eNB
- OW Period int 0~214748
3647
- -
Retain_Sessio
nTimeQCI
ms Total in-session time - OW Period float 0~60*Peri
od*1000
- -
xQCI
xQCIxQCI
QCIeQCISessionTimERAB
QCIlActNbrERABR
_.
_Re.1
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 409 of 427
2600-00FET7GAT 6.0
24.4 INTEGRITY
A KPI that shows how E-UTRAN impacts the service quality provided to an end-user.
Payload data volume on IP level per elapsed time unit on the Uu interface.
E-UTRAN IP Throughput
Samples
Samples
DLtpT
DLtpV
ThroughputIP__
__
_
E-UTRAN IP Latency
xQCIxQCI IPLatDlDRBLatDownlink .
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 410 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EutranIpThroughput Kbps EutranIpThroughput per QCI Y OW Period float 0-3.4*10^38 - avg
(EutranIpThroughput)
EutranIpLatency ms EutranIpLatency per QCI Y OW Period float 0-60*Period*1000 - avg
(EutranIpLatency)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 411 of 427
2600-00FET7GAT 6.0
24.5 AVAILABILITY
A KPI that shows availability of E-UTRAN cell.
Percentage of time that the cell is considered available.
For the cell availability, provides the statistics of the elapsed time from the cell down due to the fault until its recovery.
E-UTRAN Cell Availability
100_
]ime.[causeavailableTRRU.CellUn-t_periodmeasuremencause
periodtmeasuremenbilityCellAvaila
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
EutranCellAvail
ability
% Percentage of time that the
cell is considered available
Y OW Period float 0-100 (cellAvail_pmPeri
odTime-
read_CellUnavail
ableTime)*100/c
ellAvail_pmPerio
dTime
(sum
(cellAvail_pmPeriodTi
me)-sum
(read_CellUnavailable
Time))*100/sum
(cellAvail_pmPeriodTi
me)
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 412 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
read_CellUnav
ailableTime
s Disabled time per unit time - OW Period int 0~60*Period - -
cellAvail_pmPe
riodTime
s Data collection interval - OW Period int 0~60*Period - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 413 of 427
2600-00FET7GAT 6.0
24.6 MOBILITY
A KPI that shows how E-UTRAN Mobility functionality is working.
Success rate of E-UTRAN mobility.
%100.QCIHO.PrepAtt
c.QCIHO.PrepSuc
HO.ExeAtt
HO.ExeSuccRateSuccessMobility
xQCI
xQCI
xQCI
The handover is calculated for each case to produce the KPI.
Intra eNB Handover
X2 Handover Out
X2 Handover In
S1 Handover Out
S1 Handover In
Inter-RAT Handover
HO.PrepAtt.QCI is calculated by HO.PrepSucc.QCI+HO.PrepFail.QCI.
Index
Name Range Description
cNum 0~2 Cell Index
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 414 of 427
2600-00FET7GAT 6.0
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
EutranMobilityHOI
ntra
% HOIntra success rate
of E-UTRAN mobility
Y OW Period float 0-100 sumHOIntra_Succ/
sumHOIntra_Att*100
sum (sumHOIntra_Succ)/
sum (sumHOIntra_Att)*100
sumHOIntra_Att count Total intra handover
attempt count
- OW Period int 0~214748
3647
- -
sumHOIntra_Succ count Total intra handover
execution success
count
- OW Period int 0~214748
3647
- -
sumHOIntra_Prep
Succ
count Total intra handover
preparation success
count
- OW Period int 0~214748
3647
- -
EutranMobilityHO
X2Out
% HOX2Out success
rate of E-UTRAN
mobility
Y OW Period float 0-100 sumHOX2Out_Succ/s
umHOX2Out_Att*100
sum (sumHOX2Out_Succ)/
sum (sumHOX2Out_Att)*
100
sumHOX2Out_Att count Total X2 handover
attempt count in SeNB
- OW Period int 0~214748
3647
- -
sumHOX2Out_Su
cc
count Total X2 handover
execution success
count in SeNB
- OW Period int 0~214748
3647
- -
sumHOX2Out_Pr
epSucc
count Total X2 handover
preparation success
count in SeNB
- OW Period int 0~214748
3647
- -
EutranMobilityHO
X2In
% HOX2In success rate
of E-UTRAN mobility
Y OW Period float 0-100 sumHOX2In_Succ/(su
mHOX2In_Att*100
sum (sumHOX2In_Succ)/
sum (sumHOX2In_Att)*100
sumHOX2In_Att count Total X2 handover - OW Period int 0~214748 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 415 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
attempt count in TeNB 3647
sumHOX2In_Succ count Total X2 handover
execution success
count in TeNB
- OW Period int 0~214748
3647
- -
sumHOX2In_Prep
Succ
count Total X2 handover
preparation success
count in TeNB
- OW Period int 0~214748
3647
- -
EutranMobilityHO
S1Out
% HOIS1Out success
rate of E-UTRAN
mobility
Y OW Period float 0-100 sumHOS1Out_Succ/s
umHOS1Out_Att*100
sum (sumHOS1Out_Succ)/
sum (sumHOS1Out_Att)*
100
sumHOS1Out_Att count Total S1 handover
attempt count in SeNB
- OW Period int 0~214748
3647
- -
sumHOS1Out_Su
cc
count Total S1 handover
execution success
count in SeNB
- OW Period int 0~214748
3647
- -
sumHOS1Out_Pr
epSucc
count Total S1 handover
preparation success
count in SeNB
- OW Period int 0~214748
3647
- -
EutranMobilityHO
S1In
% HOS1In success rate
of E-UTRAN mobility
Y OW Period float 0-100 sumHOS1In_Succ/su
mHOS1In_Att*100
sum (sumHOS1In_Succ)/
sum (sumHOS1In_Att)*100
sumHOS1In_Att count Total S1 handover
attempt count in TeNB
- OW Period int 0~214748
3647
- -
sumHOS1In_Succ count Total S1 handover
execution success
count in SeNB
- OW Period int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 416 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
sumHOS1In_Prep
Succ
count Total S1 handover
preparation success
count in TeNB
- OW Period int 0~214748
3647
- -
EutranMobilityHOI
nterRatHrpd
(Not applicable for
3UK)
% HOInterRat success
rate of E-UTRAN
mobility
Y OW Period float 0-100 sumHOInterRatHrpd_
Succ/sumHOInterRat
Hrpd_Att*100
sum (sumHOInterRatHrpd_
Succ)/sum
(sumHOInterRatHrpd_Att)*
100
sumHOInterRatHr
pd_Att
(Not applicable for
3UK)
count Total Inter RAT
Optimized HRPD
handover attempt
count
- OW Period int 0~214748
3647
- -
sumHOInterRatHr
pd_Succ
(Not applicable for
3UK)
count Total Inter RAT
Optimized HRPD
handover execution
success count
- OW Period int 0~214748
3647
- -
sumHOInterRatHr
pd_PrepSucc
(Not applicable for
3UK)
count Total Inter RAT
Optimized HRPD
handover preparation
success count
- OW Period int 0~214748
3647
- -
EutranMobilityHOI
nterRatUtranOut
% HOInterRatUtranOut
rate of E-UTRAN
mobility
Y OW Period float 0-100 sumHOInterRatUtran
Out_Succ/sumHOInter
RatUtranOut_Att*100
sum
(sumHOInterRatUtranOut_
Succ)/sum
(sumHOInterRatUtranOut_
Att)*100
sumHOInterRatUtr
anOut_Att
count Total LTE to Inter-RAT
UTRAN handover
- OW Period int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 417 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
attempt count
sumHOInterRatUtr
anOut_Succ
count Total LTE to Inter-RAT
UTRAN handover
preparation failure
count
- OW Period int 0~214748
3647
- -
sumHOInterRatUtr
anOut_PrepSucc
count Total LTE to Inter-RAT
UTRAN handover
preparation success
count
- OW Period int 0~214748
3647
- -
EutranMobilityHOI
nterRatUtranIn
% HOInterRatUtranIn
rate of E-UTRAN
mobility
Y OW Period float 0-100 sumHOInterRatUtranI
n_Succ/sumHOInterR
atUtranIn_Att*100
sum
(sumHOInterRatUtranIn_Su
cc)/sum
(sumHOInterRatUtranIn_Att
)*100
sumHOInterRatUtr
anIn_Att
count Total Inter-RAT
UTRAN to LTE
handover attempt
count
- OW Period int 0~214748
3647
- -
sumHOInterRatUtr
anIn_Succ
count Total Inter-RAT
UTRAN to LTE
handover execution
success count
- OW Period int 0~214748
3647
- -
sumHOInterRatUtr
anIn_PrepSucc
count Total Inter-RAT
UTRAN to LTE
handover preparation
success count
- OW Period int 0~214748
3647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 418 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
EutranMobilityHoI
nter
% Probability that an
end-user successfully
completes a handover
to a separate eNB of
the same frequency
Y OW Period float 0-100 (sumHOS1Out_Succ+
sumHOX2Out_Succ)/(
sumHOS1Out_Att+su
mHOX2Out_Att)*100
(sum
(sumHOS1Out_Succ)+sum
(sumHOX2Out_Succ))/(su
m (sumHOS1Out_Att)+sum
(sumHOX2Out_Att))*100
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 419 of 427
2600-00FET7GAT 6.0
24.7 SUCCESS_RATE
RRC success rate, ERAB success rate, and call drop rate are calculated based on the RRC, ERAB, CALL_DROP, and HO statistics co
llected.
Index
Name Range Description
cNum 0~2 Cell Index
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
RrcEstabSuccess
Ratio
% RRC ESTAB success
rate
Y OW Period float 0~100 (SumRrcEstabSuccess/
SumRrcEstabAttempt)*
100
(sum(SumRrcEstabSucc
ess)/sum(SumRrcEstabA
ttempt)) * 100
ErabEstabSuccess
Ratio
% ERAB ESTAB success
rate
Y OW Period float 0~100 (SumErabEstabSucces
s/SumErabEstabAttem
pt)*100
(sum(SumErabEstabSuc
cess)/sum(SumErabEsta
bAttempt)) * 100
CallDropRatio ratio Call drop rate Y OW Period float 0~1 SumCallDrop_ECCB_D
SP_AUDIT_RLC_MAC
_CALL_RELEASE+Su
mCallDrop_ECCB_RC
V_RESET_REQUEST_
FROM_ECMB+SumCal
lDrop_ECCB_RCV_CE
LL_RELEASE_IND_FR
OM_ECMB+SumCallDr
sum(SumCallDrop_ECC
B_DSP_AUDIT_RLC_M
AC_CALL_RELEASE+Su
mCallDrop_ECCB_RCV_
RESET_REQUEST_FRO
M_ECMB+SumCallDrop_
ECCB_RCV_CELL_REL
EASE_IND_FROM_ECM
B+SumCallDrop_ECCB_
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 420 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
op_ECCB_RADIO_LIN
K_FAILURE+SumCallD
rop_ECCB_DSP_AUDI
T_MAC_CALL_RELEA
SE+SumCallDrop_ECC
B_ARQ_MAX_RE_TRA
NSMISSION+SumCall
Drop_ECCB_DSP_AU
DIT_RLC_CALL_RELE
ASE+SumCallDrop_EC
CB_TMOUT_rrcConne
ctionReconfig+SumCall
Drop_ECCB_TMOUT_r
rcConnectionReEstabli
sh+SumCallDrop_ECC
B_S1_SCTP_OUT_OF
_SERVICE/SumEstabIn
itSuccNbr+SumInterX2I
nSucc+SumInterS1InS
ucc+SumRatInSuccUT
RAN
RADIO_LINK_FAILURE+
SumCallDrop_ECCB_DS
P_AUDIT_MAC_CALL_R
ELEASE+SumCallDrop_
ECCB_ARQ_MAX_RE_T
RANSMISSION+SumCall
Drop_ECCB_DSP_AUDI
T_RLC_CALL_RELEASE
+SumCallDrop_ECCB_T
MOUT_rrcConnectionRe
config+SumCallDrop_EC
CB_TMOUT_rrcConnecti
onReEstablish+SumCall
Drop_ECCB_S1_SCTP_
OUT_OF_SERVICE) /
sum(SumEstabInitSuccN
br+SumInterX2InSucc+S
umInterS1InSucc+SumR
atInSuccUTRAN)
SumRrcEstabAtte
mpt
count Total RRC ESTAB
attempt count for each
cell
- OW Period int 0~21474
83647
- -
SumRrcEstabSucc
ess
count Total RRC ESTAB
success count for
each cell
- OW Period int 0~21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 421 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
SumErabEstabAtt
empt
count Total ERAB ESTAB
attempt count for each
cell
- OW Period int 0~21474
83647
- -
SumErabEstabSuc
cess
count Total ERAB ESTAB
success count for
each cell
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_DSP_AUDIT_
RLC_MAC_CALL_
RELEASE
count Total count that a call is
released due to
resource mismatch
because the ECCB has
remaining calls but the
RLC and the MAC
have no remaining calls
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_RCV_RESET
_REQUEST_FRO
M_ECMB
count Total count that a call
is released when a
reset request is
received from the
ECMB block due to
refork of a specific
block in the eNB
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_RCV_CELL_R
ELEASE_IND_FR
OM_ECMB
count Total count that a call
is released when a
Cell Release Ind
message is received
from the ECMB block
because of DSP down
- OW Period int 0~21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 422 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
or CPRI failure caused
by a problem in DSP
SumCallDrop_EC
CB_RADIO_LINK
_FAILURE
count Total count that a call
is released due to
radio link failure
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_DSP_AUDIT_
MAC_CALL_REL
EASE
count Total count that a call
is released due to
resource mismatch
because the ECCB
and the RLC have
remaining calls but the
MAC has no
remaining calls
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_ARQ_MAX_R
E_TRANSMISSIO
N
count Total count that a call
is released when ARQ
ACK is not received
from the UE after the
RLC performs as
many transmission as
the Max
Retransmission to the
UE.
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_DSP_AUDIT_
RLC_CALL_RELE
ASE
count Total count that a call
is released due to
resource mismatch
because the ECCB
- OW Period int 0~21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 423 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
and the MAC have
remaining calls but the
RLC has no remaining
calls
SumCallDrop_EC
CB_TMOUT_rrcC
onnectionReconfig
count Total count that a call
is released when the
RRC Connection
Reconfiguration
Complete message is
not received after the
RRC Connection
Reconfiguration
message is sent
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_TMOUT_rrcC
onnectionReEstabl
ish
count Total count that a call
is released when the
RRC Connection
Reestablishment
Complete message is
not received after the
RRC Connection
Reestablishment
message is sent
- OW Period int 0~21474
83647
- -
SumCallDrop_EC
CB_S1_SCTP_O
UT_OF_SERVICE
count Total count that a call
is released when the
S1 Association’s
status is changed from
In Service to Out of
- OW Period int 0~21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 424 of 427
2600-00FET7GAT 6.0
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max Granularity Formula
Hourly, Daily, Monthly
Formula
Service
SumEstabInitSucc
Nbr
count Total ERAB ESTAB
success count for
each cell
- OW Period int 0~21474
83647
- -
SumInterX2InSucc count Total X2 handover
execution success
count for each cell in
TeNB
- OW Period int 0~21474
83647
- -
SumInterS1InSucc count Total S1 handover
execution success
count for each cell in
TeNB
- OW Period int 0~21474
83647
- -
SumRatInSuccUT
RAN
count Total Inter-RAT
UTRAN to LTE
handover execution
success count for
each cell
- OW Period int 0~21474
83647
- -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 425 of 427
2600-00FET7GAT 6.0
24.8 Connection Drop Rate
Indicates the ratio of number of abnormally terminated connections based on the number of created ERABs.
Index
Name Range Description
cNum 0~2 Cell Index
mcID 0~0 Subcell Index (displayed only for smart cell configuration; included in the statistics)
QCI 0~255 QoS Class Identifier
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
ConnDropRate % probability that an end-user
abnormally lost an E-UTRAN
Radio Access Bearer
Y OW Period float 0~100 CdrRelActive/(Cd
rSumEstabInitSuc
cNbr+CdrEstabA
ddSuccNbr)*100
sum(CdrRelActive)/(s
um(CdrSumEstabInit
SuccNbr)+sum(CdrEs
tabAddSuccNbr))*100
CdrSumEstabI
nitSuccNbr
coun Total ERAB ESTAB success
count
- OW Period int 0~2147483647 - -
CdrEstabAddS
uccNbr
count ERAB additional setup success
count
- OW Period int 0~2147483647 - -
CdrRelActive count Total count of bearers among
active E-RABs where a call is
released due to abnormal
operation in eNB
- OW Period int 0~2147483647 - -
Ver.
Statistics Items
© SAMSUNG Electronics Co., Ltd. page 426 of 427
2600-00FET7GAT 6.0
25 UE_Category
25.1 UE Category
This section provides statistics for the number of UE for each UE Category. eNB performs count by Category of EMM-Registered UE.
Type
Name Unit Description Visible Counter
Type
Trigger
Type
Data
Type Min/Max
Granularity
Formula
Hourly, Daily,
Monthly Formula
UE_Category_1 count The number of UE for UE Category 1 Y CC event int 0~2147483647 - -
UE_Category_2 count The number of UE for UE Category 2 Y CC event int 0~2147483647 - -
UE_Category_3 count The number of UE for UE Category 3 Y CC event int 0~2147483647 - -
UE_Category_4 count The number of UE for UE Category 4 Y CC event int 0~2147483647 - -
UE_Category_5 count The number of UE for UE Category 5 Y CC event int 0~2147483647 - -
Ver.
© SAMSUNG Electronics Co., Ltd. page 427 of 427
2600-00FET7GAT 6.0
LTE eNB
System Counter Description
_SLR2.4
© 2013 Samsung Electronics Co., Ltd.
All rights reserved.
Information in this manual is proprietary to SAMSUNG
Electronics Co., Ltd.
No information contained here may be copied, translated,
transcribed or duplicated by any form without the prior written
consent of SAMSUNG.
Information in this manual is subject to change without notice.