Liquid target system for New TPC experiment

10
Liquid target system for New TPC experiment •System •Target cell •Performance in test experiment •Plan for next experiment •Perspective

description

Liquid target system for New TPC experiment. System Target cell Performance in test experiment Plan for next experiment Perspective. CFRP (1mm). L.T. System. g. 40 mm. ~500 mm. 145 mm. Target. Kapton Cell. Temperature sensor (Cernox). Target stage. 25mm. 33 mm. - PowerPoint PPT Presentation

Transcript of Liquid target system for New TPC experiment

Page 1: Liquid target system for New TPC experiment

Liquid target system for New TPC experiment

•System•Target cell•Performance in test experiment•Plan for next experiment•Perspective

Page 2: Liquid target system for New TPC experiment

L.T. System

CFRP (1mm)

Page 3: Liquid target system for New TPC experiment

Target

~500 mm145 mm

40 mm

33 m

m

25mm

Kapton Cell

Target stage

Temperature sensor (Cernox)

Page 4: Liquid target system for New TPC experiment

Target Cell (Kapton 125 um)Nagai manufacturing Co.,Ltd.( www.nagai-mfg.co.jp )Plastic molding, etc.

Leak test (2 atm) using N2 gas.

Page 5: Liquid target system for New TPC experiment

Shielding

Page 6: Liquid target system for New TPC experiment

Operation

• 145 mm   long target cell

Filled gas with 1.35 atm using default preserver tank (120x6 litter)

• Temperature controll (Lake Shore)

set requested temperature

The heat voltage is controlled automatically.

Page 7: Liquid target system for New TPC experiment

17K15.8K

Test  (Hydrogen)

Page 8: Liquid target system for New TPC experiment

For next experiment

100 mm longer

Page 9: Liquid target system for New TPC experiment

TargetCollimatorHole 31.7x24 mm

2 T

T=3 GeV, N=105, (x,y)=(8mm,4mm)

(In&Out&Upbar)No LH2 3 No buffer 11LH2 12

33x25 mm

Setup

(100)3 mm

Page 10: Liquid target system for New TPC experiment

Further

• Helium 4

The liquidized was achieved using copper cell at Suzuki co.

R&D for the target cell

Kapton Aramid, etc.