Multi-Service Fiber Optical Multiplexer LightSmart -PE150E TM User’s Manual

Transcript of LightSmart PE150E LOE 990805

Page 1: LightSmart PE150E LOE 990805

Multi-Service Fiber Optical Multiplexer

LightSmart -PE150E TM

User’s Manual

Page 2: LightSmart PE150E LOE 990805
Page 3: LightSmart PE150E LOE 990805

Table of Contents

CHAPTER I INTRODUCTION ..........................................................................................1

1-1 PRODUCT DESCRIPTION ..................................................................................................1 1-2 APPLICATION DIAGRAM ..................................................................................................1 1-3 PRODUCT FEATURES........................................................................................................2 1-4 TECHNICAL SPECIFICATIONS ...........................................................................................3

CHAPTER II INSTALLATION GUIDE ............................................................................6

2-1 UNPACKING.....................................................................................................................6 2-2 SITE REQUIREMENT ........................................................................................................6 2-3 SITE SELECTION ..............................................................................................................7 2-4 DC ELECTRICAL OUTLET CONNECTION ..........................................................................7 2-5 LASER SAFETY................................................................................................................7

CHAPTER III PANEL DESCRIPTION .............................................................................8

3-1 FRONT PANEL..................................................................................................................8 3-2 REAR PANEL....................................................................................................................9

CHAPTER IV SYSTEM OPERATION INSTRUCTION...............................................12

4-1 VT-100 OPERATION ......................................................................................................12 4-1-1 Startup Loading / Booting and Login Screen..........................................................13 4-1-2 Main Menu...........................................................................................................15 4-1-3 System Configuration...........................................................................................16

4-1-3.1 System Information Configuration ..................................................................17 4-1-3.2 Device Networking Configuration...................................................................18 4-1-3.3 User Account Management..............................................................................19 4-1-3.4 SNMP Agent Configuration.............................................................................21 4-1-3.5 Software Upgrade Configuration.....................................................................22 4-1-3.6 Software Upgrade and Reboot Operation........................................................24 4-1-3.7 Network Time Synchronization .......................................................................28 4-1-3.8 Scheduling Job Management ...........................................................................30 4-1-3.9 Networking Service Management....................................................................32 4-1-3.10 Network TroubleShooting Operation.............................................................33 4-1-3.11 LCD Login Configuration..............................................................................35 4-1-3.12 Event Management ........................................................................................36 4-1-3.13 System Profile Management ..........................................................................39 4-1-3.14 Configuration File Management ....................................................................41 4-1-3.15 Terminal File Transfer Operation...................................................................45

4-1-4 Tributary Slot Interface Selection ........................................................................46 i

Page 4: LightSmart PE150E LOE 990805

4-1-4.1 E1 Interface Configuration.............................................................................. 47 4-1-4.2 V.35/X.21/RS530 Interface Configuration ...................................................... 49 4-1-4.3 FXO/FXS Interface Configuration.................................................................. 51 4-1-4.4 T1 Interface Configuration.............................................................................. 52 4-1-4.5 RS232 Interface Configuration ....................................................................... 53 4-1-4.6 Tributary TSA Configuration .......................................................................... 54

4-1-5 Optical Interface Parameters Configuration ...................................................... 62 4-1-6 Trunk Ethernet Configuration Selection.............................................................. 64

4-1-6.1 Trunk Ethernet General Parameter Config...................................................... 65 4-1-6.2 Trunk Ethernet Parameters Config .................................................................. 66 4-1-6.3 Trunk Ethernet Port Rate Configuration ......................................................... 67 4-1-6.4 Trunk Ethernet Port VLAN Config ................................................................. 68 4-1-6.5 Trunk Ethernet QoS Port Config ..................................................................... 69 4-1-6.6 Trunk Ethernet VLAN Table Config Management ......................................... 70 4-1-6.7 Trunk Ethernet QoS Schedule Config ............................................................. 71 4-1-6.8 Trunk Ethernet QoS Tag Priority Config......................................................... 72 4-1-6.9 Trunk Ethernet Tag Mark/Remark Config ...................................................... 73

4-1-7 Data Port Parameters Configuration ................................................................. 74 4-1-8 Performance Management Threshold Configuration.......................................... 75

4-1-8.1 Dsx1 Interface Threshold Setting.................................................................... 76 4-1-8.2 Aggregate Interface Threshold Setting............................................................ 78

4-1-9 Fault Management Parameters Configuration ................................................... 79 4-1-9.1 Alarm Severity Config .................................................................................... 80 4-1-9.2 Power Failure Monitoring Parameter Config.................................................. 81

4-1-10 OE Protection Switching ................................................................................... 82 4-1-11 Equipment Status Monitoring ............................................................................ 84 4-1-12 Performance Monitoring................................................................................... 87

4-1-12.1 Aggregate/Dsx1 Performance Monitoring .................................................... 88 4-1-12.2 Trunk Ethernet Performance Monitoring ...................................................... 90

4-1-13 Path Alarm/State Monitoring ............................................................................ 91 4-1-14 Loopback/V.54 Testing....................................................................................... 92 4-1-15 PRBS Test .......................................................................................................... 96 4-1-16 Event Browsing.................................................................................................. 99

4-2 LCD OPERATING INSTRUCTIONS ................................................................................ 100 4-2-1 LCD Menu Tree ................................................................................................. 101

4-3 WEB OPERATING INTERFACE ...................................................................................... 105 4-4 TELNET OPERATING.................................................................................................... 108

APPENDIX........................................................................................................................... 109

A-1 CARFT & EXTERNAL ALARM PORTS PIN ASSIGNMENT .............................................. 109

ii

Page 5: LightSmart PE150E LOE 990805

A-2 PIN ASSIGNMENT FOR TRIBUTARY T1 PAD.................................................................. 110 A-3 DB25 PIN ASSIGNMENT FOR TRIBUTARY T1 LINE CONNECTION................................ 111 A-4 TROUBLESHOOTING GUIDE ........................................................................................ 112

iii

Page 6: LightSmart PE150E LOE 990805
Page 7: LightSmart PE150E LOE 990805

Chapter I Introduction

1-1 Product Description

The LightSmart-PE150E is a powerful Fiber Optical multiplexer which can aggregate various of services into a pair of fiber. It supports E1, T1, V.35, RS232, FXO/FXS and a built in four 10/100M Ethernet port. It supports the 1+1 hot-swappable optical protection. The LightSmart-PE150E can be managed through SNMP, Web Interface, VT100 craft port or LCD/menu keys. It also supports external alarm function for alarm input monitor purpose. It is 1U, 19” rack mountable or desktop type model.

The LightSmart-PE150E provides local/remote loopback functions for optical and E1interfaces. It is very convenient for network testing and maintenance. Embedded operation channel (EOC) is built between local and remote sides for system configuration, testing, performance and alarm monitoring of each E1 channel and optical link. For performance monitoring, the LightSmart-PE150E also provides BPV and CRC error count for each E1 electrical link and parity error count for optical link.

1-2 Application Diagram

Ethernet

SDH

PSTN

LightSmart-PE150E

BSC(2G)/BNC(3G)

E1

CO.

E1 E1

Router

Ethernet

V.35

Core Switch

2G/3G Base Station

LightSmart-PE150E

E1

PBX

EnterpriseLAN

V.35

E1

Router

CPE.

1

Page 8: LightSmart PE150E LOE 990805

1-3 Product Features

Channel interface: 4E1, 8E1, 12E1, 16E1, 4T1, 8T1, 12T1, 16T1, 4V.35, 4*RS232, FXO/FXS, 4*10/100Base-T Ethernet ports

Optical module:Auto Laser shutdown(ALS), hot swappable 1+1 protection(Signal Failure or BER≧10 ) -5

Alarm relay contact:major and minor alarms (audible and visible alarm output)

External Alarm input

Support SNMP function, HTTP / FTP / TFTP remote software upgradeable

Support the TELNET function to configure and monitor local and remote devices through the TCP/IP network.

Provides the parity error count for optical interface performance monitoring

Configurations can have backup in nonvolatile memory.

Configuration file upload / download.

Aggregated ethernet throughput up to 100Mbps.

Provides the optical line local loopback and remote loopback function.

Provides E1 to V.35 cross connections.

Low speed (E1, V.35) Local and remote loopback function

Management interface:LCD / keys button, VT100 (DB9), RJ45 (for SNMP or Web Interface)

OE module: Class 1 Laser product. Safety Standard IEC 825 compliant

2

Page 9: LightSmart PE150E LOE 990805

1-4 Technical Specifications

E1 Interface card:

Channel Capacity:4E1 Bit Rate:2.048Mbps ± 50ppm Compliance standard: ITUG.703 Line Code:HDB3 / AMI Electrical Interface:Compliant with international standards ITU-T G.703 Jitter Tolerance:Compliant with ITU-T G.823 Jitter Transfer:Compliant with ITU-T G.742 Line impedance:75Ω(Unbalanced) or 120Ω(Balanced)

V.35 Interface card:

Data rate:n*64K, n=1~32 (64~2048kb/s) Clock mode:Internal, External DTE, Recovery. Control signal:CTS follows RTS, DSR always ON except at test

loop mode, DCD always ON except at fiber loss of signal condition.

Loop-back:local loop back, remote loop back, V.54 Connector:M34 Female on board

RS232 Interface card (DCE):

Channel Capacity:4 RS232 Bit Rate:UP to 115200 bps

TXD/RXD 1.536Mbit/s DTR/DSR 128Kbit/s RTS/CTS 128Kbit/s DCD/RI 64Kbit/s

Support Local loopback Support Remote loopback

3

Page 10: LightSmart PE150E LOE 990805

T1 Interface card:

Channel Capacity: 4/8/12/16 channels Bit Rate: 1.544Mbps±50ppm Line Code: B8ZS / AMI Frame Format: Frame or Unframed Electrical Interface: Compliant with international standards ITU-T G.703 Jitter Tolerance: Compliant with ITU-T G.824 Jitter Transfer: Compliant with ITU-T G.824 Line impedance: 100Ω(DB25 Wire Wrap, RJ45) Surge protection: Compliance with (or better than) IEC 1000-4-5 class

2 or FCC part 68 Line buildout: 5 segments

LBO1:0~133feet / LBO2:133~266feet / LBO3:266~399feet LBO4:399~533feet / BO5:533~655feet

FXO/FXS Interface card:

Voice channel transparent to meet T.38 and Group III Fax relay at 2.4~14.4kbps Fax application

Support modem pass-through for Internet application. Comply with G.711 A-law. FXO unit: connected to a central office or PBX FXS unit: connected to customer’s telephone. Distance / bandwidth: 300m / 64K voice channel. Connector: RJ11*4 (4 voice channel / Per unit)

Optical Interface:

Optical Source:MLM 1310/1550nm Wavelength:1310/1550 ± 50nm System Gain:19~30dB Fiber connector types:SC,FC type Bi-directional Fiber Optical Module (Option) 1+1 hot-swappable optical protection

4

Page 11: LightSmart PE150E LOE 990805

10/100M Ethernet Interface: Compliance:IEEE 802.3/802.3u Configuration modes:10/100M, full/half-duplex, auto-negotiation and

auto MDI/MDIX. Maximum packet length 1536/1522 Bytes. Frame buffer:329 frames, IEEE 802.3X standard. MAC Table:1024-entry MAC address mapping table. Connector: RJ-45 Throughput 100Mbps(4 Ports Shared) Support Port Base VLAN, Tag Based VLAN 802.1Q Support defining QoS in each port and Support 802.1p QoS

Physical Specifications:

Alarm contact:4 relay contacts (DB-9 connector) External Alarm: (DB-9 connector)

input voltage: 0~60VDC, input current: 1~5mA

Operate condition:0~50, 5%~95% without condensing EMI:Comply with CISPR 22 class A (EN55022), FCC part 15 class A

subpart B. MTBF:48,000 hours minimum

Working Environment:

Temperature:5 to 40 Relative Humidity:85% at 30

Power Supply:

AC:90~240 V (47Hz~63Hz) DC:-36~-72 V Power consumption 30W maximum With power redundancy for protection (Optional)

Dimension:

W * D * H:440 x 255 x 44.5 mm

5

Page 12: LightSmart PE150E LOE 990805

Chapter II Installation Guide

This chapter provides the information needed to install LightSmart-PE150E. It is important to follow the installation instruction to ensure normal operation of the system and to prevent damages due to human error.

Only trained and qualified personnel should be allowed to install or replace this equipment.

2-1 Unpacking

If there is a possibility for future relocation of the LightSmart-PE150E system, please save the cartons and protection packaging material. The following items are shipped with your LightSmart-PE150E:

One LightSmart-PE150E user’s manual CD, AC power cord and DB9 cable. One (or numerous units of) LightSmart-PE150E chassis system

Please carefully unpack and inspect the unit and accessories for

potentially damaged and missing parts. Contact our nearest sales representative or our company directly if you suspect any damaged or missing parts. Improper handling during shipment may cause early failure.

2-2 Site Requirement

The F.C.C. requires telecommunication equipment to withstand electrical surge that may result from lighting strikes. This equipment has been tested and found to comply with the F.C.C. requirement. Users should follow the precautions below to insure the safety and minimize the risk of damage to the equipment:

Make sure that the power outlet is properly grounded. Proper grounding should include a minimum of: 1) A grounded rod buried outside the building at least 8 feet (2.44 meters)

deep.

6

Page 13: LightSmart PE150E LOE 990805

2-3 Site Selection

The LightSmart-PE150E to allow easy access to the equipment, leave at least 36 inches (90 cm) clearance in the front and at least 4 inches (10.2 cm) at the rear.

To avoid overheating, leave at least 1 inch (2.5 cm) on either side of

LightSmart-PE150E. Also, do not stack other equipment on top of LightSmart-PE150E.

2-4 DC Electrical Outlet Connection

For safety and to prevent damages to LightSmart-PE150E, make sure that the power requirement matches those of your electric outlets. Connect power to LightSmart-PE150E and power on the equipment.

2-5 Laser Safety

Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.

7

Page 14: LightSmart PE150E LOE 990805

Chapter III Panel Description

3-1 Front Panel

(1) OE Module: LSRON LED →Yellow light when the laser is on

LOS LED →Red light when the laser is loss of signal WK LED → Working path indicator RX →Optical Receiver Port TX →Optical Transmitter Port

(2) LAN1/2/3/4 port : 100M full rate for each port (3) Mgmt Port: RJ-45 connector to SNMP management system (4) MAJ LED: Red light when there is a Major Alarm present (5) MIN LED: Yellow LED lights when there is a Minor Alarm present (6) LBK LED:Yellow LED lights when there is a loopback function presents. (7) RDI LED: Remote Defect Indication;

Indicates a failure in the remote terminal (8) PWR LED:Green LED lights when power module active. (9) LCK LED:Optical link Lock; The optical is locked when optical is switched to protect

line 6 times within 10 minutes (10) ACO LED:Alarm Cut Off function indicator (11) ACO Button: Alarm Cut Off; Yellow light when the ACO button is pressed to

manually disable the audible alarm when a problem occurs. If any newer alarm is reported after the ACO button has been pressed, the external alarm will activate again.

(12) Craft Port: For VT-100 screen setup using. (13) RST Button: Restart the system (14) Button: LCD control key buttons for the configuration of the LightSmart-PE150E

RST

OE 2 OE 1 PWRMAJ

MINLBKRDI

LCKACO

LAN1 LAN2 LAN3 LAN4 MGMT

LSR ON

LOS WK

Tx Rx LSR LOS ON

WK

Tx Rx

LOS/LOF/AIS

1 2 3 4E1/V35

1234

PORTS

CRAFT

8

Page 15: LightSmart PE150E LOE 990805

3-2 Rear Panel

Power Switches: On/Off switch for LightSmart-PE150E

LightSmart-PE150E provides three kinds of tributary interfaces card and different power supply combinations with the DC/AC power supply.

(a) E1 tributary card

There are two types of E1 cards for selection: 75Ωor 120Ω. E1_75Ω:One DB-25 pins female connector for input/output of 4 channels

E1 signal.

E1_120Ω:Four RJ45 interface for input/output of 4 channels E1 signal.

FGND RTN –48V

AC 110~220V

ALARM TB1 TB2 TB3 TB4

Anyone tributary card

Anyone tributary card

Anyone tributary card

Anyone tributary card

EXT_ALM

CH4 CH3

E

CH2 CH1

1_120Ω

E1_75Ω

1,2,3,4,5,6,7,8

4、5 ping is output , 1、2 ping is input

9

Page 16: LightSmart PE150E LOE 990805

(b) T1U tributary card

One DB-25 pins female connector for input/output of 4 channels T1 signal 100Ω.

T1U

(c) 4V35 tributary card

4*V35 card, HD68 to 4*M34 Connectors to V.35 interface. (d) 4 channel FXO/FXS tributary card

FXS and FXO, FXO connected to a central office or PBX and FXS connected to customer telephone, each line FXO raises the same line FXS. Every channel provide 64k voice bandwidth.

FXS

FXO

10

Page 17: LightSmart PE150E LOE 990805

(e) X.21 tributary card

4*X21 card, HD68 to 4*M34 Connectors to X21 interface.

X.21

(f) RS232 tributary card

RS232

※ Any kind of the above cards is allowed to plugged into tributary slot 1~4.

(TB1~TB4)

11

Page 18: LightSmart PE150E LOE 990805

Chapter IV System Operation Instruction

4-1 VT-100 Operation

* Craft Port:

1. Any PC running Windows 98/2000 or NT can be used as a console. 2. Use the supplied RS-232 cable and connect the console port to the

COM port of console PC. 3. Use windows Hyper Terminal program to perform the console

management operations. But, we strongly recommend using the free software netterm which has some of special function key to control easily.

4. VT-100 terminal settings:

Bit Rate: 57600 bps Data Bit: 8 bits Parity: No Parity Stop Bit: 1 Stop bit Flow Control: none Set the emulation mode to“VT-100” or “Auto Detect”

12

Page 19: LightSmart PE150E LOE 990805

4-1-1 Startup Loading / Booting and Login Screen

When users start LightSmart-PE150E equipment, it will show the profile loading screen: There are four kinds of mode that users can select. The factory default has already built and saves in profile I/II. The default booting will select profile I.

※ Profile factory default (IP Address: 192.168.0.1) is clear all setting but

keep the IP, convenience the user through web setting

13

Page 20: LightSmart PE150E LOE 990805

The system has the built in self-diagnostic function during the booting

procedure. The self-diagnostic function includes system memory access test, system main clock test and tributary card access test. After selecting the loading profile, the booting test screen can be shown before the login screen seen:

Enter LightSmart-PE150E Login Screen through Craft Port. Please key

in the User Name and User Password. ※ The default user Name is admin and the password is 1234

14

Page 21: LightSmart PE150E LOE 990805

4-1-2 Main Menu

Press the Function keys can access the item faster. [F3] is online help, and has definition of the function key

Show system name Current location

※ Notice : Some terminal programs could not support the function keys. After entering the main menu, select one of the nine functions:

--(refer 4-16) --(refer 4-15) --(refer 4-14) --(refer 4-13)

--(refer 4-11) --(refer 4-12)

--(refer 4-10) --(refer 4-9) --(refer 4-8) --(refer 4-7) --(refer 4-6) --(refer 4-5)

--(refer 4-3) --(refer 4-4)

1. System Configuration 2. Tributary Slot Parameters Configuration 3. Optical Interface Parameters Configuration 4. Trunk Ethernet Parameters Configuration 5. Data Port Parameters Configuration 6. Performance Management Threshold Configuration 7. Fault Management Parameters Configuration 8. OE Protection Switching 9. Equipment Status Monitoring a. Performance Monitoring b. Path Alarm/State Monitoring c. Loopback/V.54 Testing d. PRBS Testing e. Event Browsing

15

Page 22: LightSmart PE150E LOE 990805

4-1-3 System Configuration

※ Notice : First of all, user need to select Local or remote units for configuration.

「System Configuration」the menu include the following selections:

1) System Information Configuration 2) Device Networking Configuration 3) User Account Management 4) SNMP Agent Configuration 5) Software Upgrade Configuration 6) Software Upgrade and Reboot Operation 7) Network Time Synchronization 8) Scheduling J ob Management 9) Networking Service Management a) Network Troubleshooting Operation b) LCD Login Configuration c) Event parameter Management d) System Profile Management e) Configuration File Management f) Terminal File Transfer Operation

Press <F1> function key to select item 1 ~ item f, and use the up or down key to shift the items. Please select the item or <ESC> to previous menu. The detail description of each item will be mentioned in the following sections.

16

Page 23: LightSmart PE150E LOE 990805

4-1-3.1 System Information Configuration

※ Notice : Here shows the local or remote device which you selected.

The system administrator can key in the system name, the location of the system, and the contact person all at most 256 characters.

The system clock can be set by entering the correct time. This

screen can show the running time of the system and the software version. After the setting of above items, please make sure to press <F2> to

save them.

17

Page 24: LightSmart PE150E LOE 990805

4-1-3.2 Device Networking Configuration

The system administrator can set the system device IP of the MGMT port in this screen.

This Internet-related setting to provide preventive mechanisms function to avoid involved in the operation of the entire network

[F2] Confirm: When users change related to IP data, click [F2] function, the

system will direct to execute and became running IP status.

[F5] Set Only: When users change related to IP data, click [F5] to be storage in temporary memory, and wait until click [F2], it to become running IP status.

18

Page 25: LightSmart PE150E LOE 990805

4-1-3.3 User Account Management

LightSmart-PE150E provides three kinds of the user groups.

Admin:the administrator group account can execute all functions.

Control:the controller group account can execute all functions except

the System Configuration.

Monitor:the monitor group account only can monitor the system except

that execute setting command.

19

Page 26: LightSmart PE150E LOE 990805

The default Auto-Logout Seconds is 0, which means disable the

auto-logout function.

This account also can disable the account status.

20

Page 27: LightSmart PE150E LOE 990805

4-1-3.4 SNMP Agent Configuration

The LightSmart-PE150E can assign four sets of the Server IP address for

sending the Traps.

The default Read Community is public.

The default Write Community is private.

The default Trap Community is public.

Enable the “Send SNMP Authentication Failure Trap” function for sending

the trap when the authentication is fail. 21

Page 28: LightSmart PE150E LOE 990805

4-1-3.5 Software Upgrade Configuration LightSmart-PE150E can support two kinds of the System Software Upgrade: Remote Server and Local File

Remote Server

Press the Space bar can change the selected

For Remote server source selection: Access Protocol: select the protocol you want to use.

(Have FTP and TFTP) Server IP Address: the server IP address where the new firmware saved. File Name: the file name of new firmware. Login User Name: key in the remote server’s user name. Login Password: key in the remote server’s password.

22

Page 29: LightSmart PE150E LOE 990805

For Local File source selection: The screen will show the available file

stored in the system. Local File

※ When you put image at local file, if you restart or re-boot power, that the

image will be disappear

23

Page 30: LightSmart PE150E LOE 990805

4-1-3.6 Software Upgrade and Reboot Operation After the software upgrade configuration is completed, the software

upgrade and reboot operation can be executed from this menu.

When user execute the [F2] Upgrade commend item in local or remote side, it will show the status: "Start upgrading!", "Connecting!", "Transferring!", "Loading!", "DeCompressing!", "Flash writing!", "Sending!", "Upgrading complete!", "None"

24

Page 31: LightSmart PE150E LOE 990805

When the software upgrade error, it will show one of the following error message:

"Internal error!", "Local file not found!", "Information incomplete!", "Upgrading is running!", "Connect failed!", "Transfer failed!", "Read failed!", "Image file too large!", "Disconnect failed!", "Decompress code failed!", "Invalid image format!", "Abort by user!", "None!"

25

Page 32: LightSmart PE150E LOE 990805

When user selects the [F3] Reboot commend item in local or remote side, it will show the message:

"Start rebooting!", "Ongoing!", "Complete, Bye-!", "None"

26

Page 33: LightSmart PE150E LOE 990805

When the screen of entering booting, please select a profile for loading. If doesn't press any key then system will auto download the previous profile after three seconds.

※ If you want to hold the screen, please press any key.

There are two temporary memory can provider user to storage: When user configuration any command in device.

27

Page 34: LightSmart PE150E LOE 990805

4-1-3.7 Network Time Synchronization

The system provides the network time synchronization function.

Setting the clock server IP address and time zone, then execute the Start

synchronizing command. The system clock will be automatically

corrected via Internet.

When user selects the synchronization commend item in local or remote side,

and "running status" will show the following message:

"Start Synchronizing!" "Synchronizing!", "Synchronizing Complete!", "Synchronizing Error!",

28

Page 35: LightSmart PE150E LOE 990805

When any error of synchronize occured one of error message will show as

below:

"Internal Error!", "Information Incomplete!", "Synchronization is running!", "Time Get Error!", "Abort by user!", "Timeout!", "No Error"

29

Page 36: LightSmart PE150E LOE 990805

4-1-3.8 Scheduling Job Management

The Scheduling Job Management function provides the automatic

timely reporting capability. The system administrator can arrange the

schedule for every kind of job. The job description is following as below.

30

Page 37: LightSmart PE150E LOE 990805

Job Type: Periodic / One shot / Booting

Schedule Type: Every Interval / Every Day

Every Interval: The system will to do select item in every interval time.

Every Day: The system will according current system time to do select item in every

day.

Interval/Time: Setting the interval time

Job: Do Nothing

Send Schedule Trap

Send Time Sync Request Trap

Software Upgrade

Network Time Synchronization

System Reboot

※ You can press the Space bar to change the selected item.

31

Page 38: LightSmart PE150E LOE 990805

4-1-3.9 Networking Service Management

The system can turn on or turn off the functions of the SNMP Agent,

TELNET Server, FTP Server, and Web Server.

When FTP Server startup, the device can act client or server, but it is small memory storage, so user can only to do software upgrade and save EventLog .

※ Attention: When you place the image of the local file, if you restart or

re-boot power, the images will disappear.

32

Page 39: LightSmart PE150E LOE 990805

4-1-3.10 Network TroubleShooting Operation

This function can provide test that the equipments whether they link to

network or not. The system provides the Network troubleshooting

function.

Setting the Target IP address, Packet Count, Length and Timeout

Seconds, then first execute to Confirm [F2], and then execute Ping start

[F5].

※ Note: The system device IP must be set first.

33

Page 40: LightSmart PE150E LOE 990805

When target IP ping succeed, it will show as below:

When target IP no answer, it will show as below: 34

Page 41: LightSmart PE150E LOE 990805

4-1-3.11 LCD Login Configuration

User need to define the login password by the key on the front

panel in sequence. From key 1 to key 4.

“Up” contrast the upward key of the panel

“Right” contrast key right of panel

“Down” contrast the downward key of the panel

35

Page 42: LightSmart PE150E LOE 990805

4-1-3.12 Event Management

LightSmart-PE150E provides Event Management function, includes

Event Class Processing Configuration、Event Alarm Processing

Configuration

36

Page 43: LightSmart PE150E LOE 990805

[1] EVENT CLASS PROCESSING CONFIGURATION

The event class processing configuration function can set the events of

the configure, alarm, and operation to save in the flash or to send the trap.

“N” is not save in the flash or not to send the trap

“Y” is save in the flash or to send the trap

※When NMS system has not received alarm trap, please confirm the send trap

function status. 37

Page 44: LightSmart PE150E LOE 990805

[2] EVENT ALARM PROCESSING CONFIGURATION

The event alarm processing configuration function can set the different

severity of the events to save in the flash or to send the trap. There are four classes of the alarm severity:

1. Critical

2. Major

3. Minor

4. Warning

※When NMS system has not received alarm trap, please confirm the send trap

function status.

38

Page 45: LightSmart PE150E LOE 990805

4-1-3.13 System Profile Management

[1] Profile Save Parameter Config

LightSmart-PE150E provides Auto-Saving function, and the auto saving interval.

39

Page 46: LightSmart PE150E LOE 990805

[2] Profile Operation

The system provides three booting profiles: Profile1 and Profile2 and

profile factory default.

If the profile had been changed before during the configuration

processing, the “Profile Modification” will show “Y”.

You can select either profile I or II then press <F2> function to save it, and after that the next booting process will automatically configure the system just like you save before.

40

Page 47: LightSmart PE150E LOE 990805

4-1-3.14 Configuration File Management

LightSmart-PE150E provides Upload file and Download file.

41

Page 48: LightSmart PE150E LOE 990805

[1] Config Upload Configuration

User must be set up upload configuration first, and then to implement “Upload or Download Operation”. Access Protocol: select the protocol you want to use. Server IP Address: the server IP address where the new firmware saved. Upload File Name: the file name of upload new firmware. Login User Name: key in the remote server’s user name. Login Password: key in the remote server’s password. File Name Extension: System Name or Device IP

or System Name+DeviceIP ※ Example File Name: LightSmart-PE150E_192.168.10.49.xml

42

Page 49: LightSmart PE150E LOE 990805

[2] Config Download Configuration

User must be set up download configuration first, and then to implement “Upload or Download Operation”.

43

Page 50: LightSmart PE150E LOE 990805

[3] Config Upload/Download Operation

User can through the function, uploaded or download the device setting to server.

44

Page 51: LightSmart PE150E LOE 990805

4-1-3.15 Terminal File Transfer Operation

45

Page 52: LightSmart PE150E LOE 990805

4-1-4 Tributary Slot Interface Selection

LightSmart-PE150E provide five tributary interfaces:

(1) E1 Interface Configuration

(2) V.35/X.21/RS530 Interface Configuration

(3) FXO/FXS Interface Configuration

(4) T1 Interface Configuration

(5) RS232 Interface Configuration

(6) Tributary TSA Configuration

46

Page 53: LightSmart PE150E LOE 990805

4-1-4.1 E1 Interface Configuration

F5: Select channel ID which you want to change the configure.

[F4]: Select 1~4 slots or all by space bar.

[F3]: Select local, remote or both site by space bar, then press the ”Enter” key to select it.

You can edit E1 Parameters for each channel or all channels of selected. [F6] Slot Edit- Edit the parameters of all channels in the same slot.

[F7]/ [F8]- You can just press [F7] or [F8] to let the selected channels in the screen go into the In-service state or out of service

47

Page 54: LightSmart PE150E LOE 990805

[F2] Edit channel screen as below:

LightSmart-PE150E have two service mode which can select:

OOS (Out of service) IS (In service)

There are three types of E1 services: FAS+CRC, FAS only, Unframed

There are two types of E1 Line Coding: HDB3 or AMI

48

Page 55: LightSmart PE150E LOE 990805

4-1-4.2 V.35/X.21/RS530 Interface Configuration

※ If the EOC connection is closed, a symbol “-“ will be shown for each

configuration. [F2] Edit channel screen as below:

49

Page 56: LightSmart PE150E LOE 990805

You can set the polarity of Tx or Rx clock to fit the requirement of different kind of DTEs.

PCM31: 64K~1984K Date Rate PCM30: 64K~1920K

Unframed: 2048K To have a stable V.35 configuration performance, you must make sure to have set the correct clock mode. The following is the example of setting. (1)

DTE

Internal Recovery

DCE CLK DCE CLK

DTE

LightSmart-PE150E LightSmart-PE150E (2)

DTE DTE

EXT-DTE Recovery

INT DCE CLK

LightSmart-PE150ELightSmart-PE150E

50

Page 57: LightSmart PE150E LOE 990805

4-1-4.3 FXO/FXS Interface Configuration [F2] Edit channel screen as below:

51

Page 58: LightSmart PE150E LOE 990805

4-1-4.4 T1 Interface Configuration [F2] Edit channel screen as below:

52

Page 59: LightSmart PE150E LOE 990805

4-1-4.5 RS232 Interface Configuration [F2] Edit channel screen as below:

If data ready detect setting is disabled, then LightSmart-PE150E won't detect the DSR (Data Set Ready) on the RS-232 interface. And the LED will show solid light by green color on the panel.

53

Page 60: LightSmart PE150E LOE 990805

4-1-4.6 Tributary TSA Configuration

LightSmart-PE150E provides six kinds of the Tributary TSA (Time slot

assignment):

1. Normal (All E1 channels)

2. 2E1+2V.35 (Two E1 channels and Two V.35 channel)

3. 7E1+1V.35 (Seven E1 channels and one V.35 channel)

4. 3E1+1V.35 (Three E1 channels and one V.35 channels)

5. CH4<->CH5 (Four E1 channels and one V.35 channels)

6. CH8<->CH9 (Eight E1 channels and one V.35 channels)

Note:

The V.35 interface setting will be set to OOS (out of service) when the mode1~4 set to the V.35 interface. Be sure to set the V.35 to IS (in service) and check the related configuration after the mode1~4 used to.

※ The Remote select, or will disappear, when the Eoc commection is closed.

54

Page 61: LightSmart PE150E LOE 990805

1. Normal mode (All E1 channels)

Local

Remote

In the normal mode, every channel can also do the PRBS testing with the corresponding channel in the remote side.

※ Notes: The clock setting needs to conform, please refer to the following pictures.

55

Page 62: LightSmart PE150E LOE 990805

(1)

E1 INT CLK

In this case, the right hand of E1 equipment is set to internal clock.

EXT

INT V35

LightSmart-PE150E LightSmart-PE150E

E1

INT

LightSmart-PE150ELightSmart-PE150E

EXT DTE

V35 DTE

E1

E1 RX CLK

RX CLK

RCV

V35

V35 DTE

(2)

In this case, the right hand of E1 equipment is set to receive clock. When V35 data is connected with E1 data, the related timing clock should be set carefully to get more stable connection!!

56

Page 63: LightSmart PE150E LOE 990805

2. Two E1 channels and two V.35 channels mode

4E1 card (Slot 1)

In this mode, user can also do the PRBS test, which is like the figure as above. The remote side’ channel can generate the test pattern to corresponding channels in the local side.

Remote (4E1 card) Ch1 Local’s (4E1 card) Ch1 Remote (4E1 card) Ch2 Local’s (4E1 card) Ch2 Remote (4E1 card) Ch3 Local’s (V35 card) Remote (4E1 card) Ch4 Local’s (V35 card)

Local’s (4E1 card) Ch3 Local’s (4E1 card) Ch4

4 3 2 1

TB1

4E1 card (Slot 1)

V35 card (Slot 2)

V35 card (Slot 3)

Remote

Local

Normal mode

mode 2E1+2V.35

TB3 TB2 TB1

These 2 channels are unavalible, when TSA function mode 1was turned on. They will be switched to "Out of Service" automatically if original setting is "In Service".

4 3 2 1

※ Note: To avoid unexpected error, DO NOT insert any card in TB2 and TB3 at

remote side, while TSA function was turned on.

57

Page 64: LightSmart PE150E LOE 990805

3. Seven E1 channels and one V.35 channel mode

4E1 card (Slot 2)

4E1 card (Slot 1)

8 7 6 5

Remote

Local

8 7 6 5 4 3 2 1

4 3 2 1

TB1TB2

TB1TB2TB3

4E1 card (Slot 2)

V35 card (Slot 3)

Normal mode 7E1+1V.35 mode 4E1 card

(Slot 1)

In this mode, user can also do the PRBS test, which is like the figure as

above. The remote side’s channel generates the test pattern to corresponding

channels in the local side.

Remote (4E1 card) Ch1 ~ Ch4 Local’s (4E1 card) Ch1~Ch4 Remote (4E1 card) Ch5 ~ Ch7 Local’s (4E1 card) Ch5 ~ Ch7 Remote (4E1 card) Ch8 Local’s (V35 card)

※ Note: To avoid unexpected error, DO NOT insert any card in TB3 at remote side,

while TSA function was turned on.

58

Page 65: LightSmart PE150E LOE 990805

4. Three E1 channels and one V.35 channels mode

4 3 2 1

4 3 2 1

TB1

TB1TB2

V35 card (Slot 2)

4E1 card (Slot 1)

4E1 card (Slot 1)

Local

Remote

3E1+1V.35 mode

Normal mode

In this mode, user can also do the PRBS test, which is like the figure as above. The remote side’ channel will generate the test pattern to corresponding channels in the local side.

Remote (4E1 card) Ch1 Local’s (4E1 card) Ch1 Remote (4E1 card) Ch2 Local’s (4E1 card) Ch2 Remote (4E1 card) Ch3 Local’s (4E1 card) Ch3 Remote (4E1 card) Ch4 Local’s (V35 card)

※ Note: To avoid unexpected error, DO NOT insert any card in TB2 and TB3 at remote

side, while TSA function was turned on.

59

Page 66: LightSmart PE150E LOE 990805

5. Four E1 channels and one V.35 channel mode

Remote

Local

5

ch5

4 3 2 1

TB1TB2

TB1TB2

Normal mode

ch ch ch ch4 3 2 1

V35 card (Slot 2)

4E1 card (Slot 1)

V35 card (Slot 2)

4E1 card (Slot 1)

(4E1+1V.35) Mode

CH4 <-> CH5

In this mode, user can also do the PRBS test, which is like the figure as

above. The remote side’s channel generates the test pattern to corresponding

channels in the local side.

Remote (4E1 card) Ch1 ~ Ch3 Local’s (4E1 card) Ch1~Ch3 Remote (4E1 card) Ch4 Local’s (V35 card) Ch5 Remote (V35 card) Ch5 Local’s (4E1 card) Ch4

※ Note: To avoid unexpected error, DO NOT insert any card in TB3 at remote side,

while TSA function was turned on.

60

Page 67: LightSmart PE150E LOE 990805

6. Eight E1 channels and one V.35 channel mode

8 7 6 5

Remote

Local

ch9

4 3 2 1

TB1TB3

TB1TB2

4E1 card (Slot 2)

4E1 card (Slot 1)

V35 card (Slot 3)

4E1 card (Slot 1)

TB2

4E1 card (Slot 2)

ch ch ch ch8 7 6 5

ch ch ch ch4 3 2 1

9

TB3

V35 card (Slot 3)

Normal mode CH8 <-> CH9 Mode

In this mode, user can also do the PRBS test, which is like the figure as

above. The remote side’s channel generates the test pattern to corresponding

channels in the local side.

Remote (4E1 card) Ch1 ~ Ch7 Local’s (4E1 card) Ch1~Ch7 Remote (4E1 card) Ch8 Local’s (V35 card) Ch9 Remote (V35 card) Ch9 Local’s (4E1 card) Ch8

※ Note: To avoid unexpected error, DO NOT insert any card in TB3 at remote side,

while TSA function was turned on.

61

Page 68: LightSmart PE150E LOE 990805

4-1-5 Optical Interface Parameters Configuration

[F2] Edit channel screen as below:

62

Page 69: LightSmart PE150E LOE 990805

[F4] ALS (Auto Laser Shutdown): Please refer to the definition of ITU-T G.664,

when LightSmart-PE150E detects “ LOS ” and the

“ ALS ” function is enabled at the same time, then

OE will shutdown the signal of Tx. It will detect

the signal automatically by every 100 seconds.

If the alarm of LOS doesn’t erase immediately,

then it needs to wait another 100 seconds again.

If the LOS status clear, the system will return to

morncal state and transmit laser signal again.

[F6] APS (Auto Protection Switch): While “OFF” selecting, “OE Revertive/

OeLocked/ OeLocked Rule/ OE Lock AutoRel

Sec” will disappear.

[F7] OE Revertive: When [F7] set to “OFF”, “OeLocked/ OeLocked Rule/ Oe Lock

AutoRel Sec” will disappear.

[F8] OE Locked: When [F8] set to “OFF”, “OeLocked Rule/ Oe Lock AutoRel Sec”

will disappear.

When [F8] set to “ON”:

OE Locked Rule: Locks the optical system if switched to protect line “ m ” times

with in “ n ” minutes. (“n” and “m” depends on user’s definition)

(Default: m=6 ; n=10 )

OE Locked AutoRel Sec: If the function of OE Locked has enabled, it will be

auto-release after “ x ” seconds. (Default: x=3600)

※ Note: If the function of the OE Locked has activate, then it needs to be real eased as

the screen of “ 4-11 OE Protection Switching “

※ Note: User can't configure the disappeared function, when user reboot the equipment

which is reload the default value.

63

Page 70: LightSmart PE150E LOE 990805

4-1-6 Trunk Ethernet Configuration Selection

In the screen user can easy to switch the port function and allow to

setting fast Ethernet rate configuration in Ethernet interface.

「Trunk Ethernet Configuration」the menu include the following selections:

[1] Trunk Ethernet General Configuration [2] Trunk Ethernet Port Configuration [3] Trunk Ethernet Port Rate Configuration [4] Trunk Ethernet Port VLAN Configuration [5] Trunk Ethernet Port QoS Configuration [6] Trunk Ethernet VLAN Table Configuration [7] Trunk Ethernet QoS Schedule Configuration [8] Trunk Ethernet QoS Tag Priority Configuration [9] Trunk Ethernet QoS Tag Mark/Remark Configuration

64

Page 71: LightSmart PE150E LOE 990805

4-1-6.1 Trunk Ethernet General Parameter Config

Tag Aware : disable (port-based)/ enable (tagged-based)

Ingress Filter : enable (drop frame associated with a VLAN for which that port is not in the member set.)

disable (disable ingress filtering)

Tag Only : disable (accepts tagged and un-tagged frames)

enable (only accepts tagged frames and drop un-tagged ones)

※ If the remote side is no device or LOS signal, the screen will not show the remote data.

65

Page 72: LightSmart PE150E LOE 990805

4-1-6.2 Trunk Ethernet Parameters Config

66

Page 73: LightSmart PE150E LOE 990805

4-1-6.3 Trunk Ethernet Port Rate Configuration

In this screen provide a method to limit the ingress and egress speed of the ethernet ports.

100M=1526 10M=152 Ingress (RX) Egress (TX)

67

Page 74: LightSmart PE150E LOE 990805

4-1-6.4 Trunk Ethernet Port VLAN Config

The VLAN ID must be between 1 and 4094.

Egress Mode:

Unmodified- Do not insert or remove VLAN tag to/from packets sent out from this port.

Untagged- If tagged packets received, the switch will remove VLAN tag

from packets. Tagged- If un-tagged packets received, the switch will add Ingress PVID.

And do nothing when switch receive any tagged packets. Retagged- If tagged packets received, switch will remove VLAN tags

than add new tags as PVID. It is a replacement processing for tagged packets and insertion for un-tagged packets.

68

Page 75: LightSmart PE150E LOE 990805

4-1-6.5 Trunk Ethernet QoS Port Config

Specifies the QoS configuration for every trunk ethernet port.

QoS Mode:

Disable - Turn off the QoS function for this port.

PortBased - Turn on the QoS function, and the priority of each packet received from this port is assigned by the following [Priority] setting. There are four priority levels, Queue1, Queue2, Queue3, and Queue4.

TagBased - In this mode, when a packet is VLAN-tagged or priority-tagged, the priority is specified by the 3-bit tag. When a packet is untagged, its priority is assigned by the following [Priority] setting.

69

Page 76: LightSmart PE150E LOE 990805

4-1-6.6 Trunk Ethernet VLAN Table Config Management

Specifies the VLAN ID and its associated port member. The VLAN must be betweem 1 and 4094.

70

Page 77: LightSmart PE150E LOE 990805

4-1-6.7 Trunk Ethernet QoS Schedule Config

Specifies the packet aggress scheduling configuration when QoS support is enabled. The packet scheduling is weighted round robin (WRR), the setting [Weight] is applied to the four queues. This approach prevents the lower priority frames from being starved out with only a slightly increased delay to the higher priority packets, and guarantee the minimal packet rate of one queue. The range of weight for each port is between 1 and 127. For Queue3 and Queue4, the strict priority scheduling is supported. If there is strict priority (only in Q2 and Q3) and WRR at the same time, the queue with strict priority has higher priority than WRR. When the scheduler scans queues, queues with strict priority are scanned first, and than the other queues are scanned according to WRR. If there is more one queue with strict priority, the queue with the bigger queue ID has higher priority.

71

Page 78: LightSmart PE150E LOE 990805

4-1-6.8 Trunk Ethernet QoS Tag Priority Config

Specifies the mapping of 3-bit tag priority to the four level priority, Queue1 ~ Queue4.

72

Page 79: LightSmart PE150E LOE 990805

4-1-6.9 Trunk Ethernet Tag Mark/Remark Config

Specifies the remarking mapping for tagged and retagged packets. When the VLAN tags are inserted to non-tagged packets, the 3-bit priority of the inserted tag will follow this configuration. When the [Egress Mode] setting is [Retagged] and the [TagRemark] setting is turned on, the priority field of VLAN tag is replaced with this tag priority of the assigned queue.

73

Page 80: LightSmart PE150E LOE 990805

4-1-7 Data Port Parameters Configuration

In this screen, users can configure different data rate of data port.

74

Page 81: LightSmart PE150E LOE 990805

4-1-8 Performance Management Threshold Configuration

This function means that when the PM value is equal or over the

threshold’s value then it will issue the TCA alarm. If TCA alarm is enabled, the alarm of TCA will be realease after is

min/day. If the value is “ 0 ” the TCA will be unabled.

(1) Dsx1 Interface Threshold Setting: Electrical interface threshold

setting.

(2) Aggregate Interface Threshold Setting: Optical interface threshold

setting.

75

Page 82: LightSmart PE150E LOE 990805

4-1-8.1 Dsx1 Interface Threshold Setting

You can use the function keys to modify the selected traffic link,

there are two PM types for choice: the quarter (15 minutes), the day

(24 hours).

[F6] Disable:Unable the PM TCA alarm on the selected E1 path by high

light bar.

[F7] All Disable:Unable the PM TCA alarm on the all selected E1 paths

by the selection filters.

76

Page 83: LightSmart PE150E LOE 990805

[F1] Line:

LCV: Line Code Violation

LES: Line Error Second

LSES: Line Several Error Second

[F3] Path:

PCV: Path Code Violation

PES: Path Error Second

PSES: Path Several Error Second

PUAS: Path Unavailable Second

77

Page 84: LightSmart PE150E LOE 990805

4-1-8.2 Aggregate Interface Threshold Setting

You can use the function keys to modify the selected traffic link, there

are two PM types for choice: the quarter (15 minutes), the day (24 hours).

78

Page 85: LightSmart PE150E LOE 990805

4-1-9 Fault Management Parameters Configuration

LightSmart-PE150E provides fault management function by setting

the alarm severity for each failure alarm.

79

Page 86: LightSmart PE150E LOE 990805

4-1-9.1 Alarm Severity Config

The administrator can define alarm severity and easy to manage alarm status.

If the alarm severity configured as Critical or Major, the MAJ LED

will be turned as red when alarm occurred. Otherwise, Minor and

Warning alarm will make MIN LED turned on as yellow.

80

Page 87: LightSmart PE150E LOE 990805

4-1-9.2 Power Failure Monitoring Parameter Config

Provide the function of power monitoring.

When “ON” is selected and the power module is failed, the alarm

will be issued.

81

Page 88: LightSmart PE150E LOE 990805

4-1-10 OE Protection Switching

User can make the active OE module locked or released and OE module manual restart from this screen.

1.Configuration:

Shown the configuration of APS (Automatic Protection Switching), ALS (Automatic Laser Shutdown), Rvt (revertive operation), LCK (lockout the active OE module) from section 4-5 “Optical Interface Parameters Configuration”.

2.OE Protection Switching Status: Shown the current status of active OE module, the status of

Lock-out mechanism, the OE module switched times by automatic or manually, and the seconds left for release after locked state. The Lock-out mechanism can be activated or deactivated by command “OE Lock/Release [F2]” on the aggregate interface. Some parameters are configured at 4-5 “Optical Interface Parameters Configuration”.

3.OE Status:

1 2 3

Shown the alarm and laser status of the OE modules. The shut down lasers can be restarted by command “OE Restart [F4]” and “OE Restart-Test [F5]” on the OE interfaces.

82

Page 89: LightSmart PE150E LOE 990805

※ Automatic laser shutdown and restart concept

The ALS mechanism implemented in LightSmart-PE150E is referred to the ITU Recommendation ITU-T G.664. The ALS mechanism can be enabled or disabled in 4-5 Optical Interface Parameters Configuration.

<< Flow Chart>>

Automatic restart Manual OE restart Manual OE restart for test

Delay time (100s)

Tx on for (2s) Tx on for (2s) Tx on for (90s)

Start

ALS opertion enable

Receive signal from far end?

Loss of received signal

Auto power shutdown

No

No

Yes

Yes

83

Page 90: LightSmart PE150E LOE 990805

4-1-11 Equipment Status Monitoring

On the equipment status monitoring screen, user can take an overall view

of the alarm status of the interlinked rack systems and it also provide operator

can easy setting tributary cards mode. And no support performance monitoring

function in CRC that is only showing card type.

“B” is for E1 Balances (75Ω) “U” is for E1 Unbalances (120Ω)

“H” is for external alarm occurred “L” is external alarm normal

“-” is for normal “F” is for “Failure” “G” is meaning “green” LED “R” is meaning “red” LED “Y” is meaning “yellow” LED “ ” is meaning the device is

b t

FAN -- is fan monitor

[Pwr] -- is power supply

84

Page 91: LightSmart PE150E LOE 990805

Local site tributary card setting:

When user plugin card in TB1, this row will showing TB card data here. User can accoreding the info then press [F2] key setting it.

Lo is meaning Local site

Into card parameters setting screen:

85

Page 92: LightSmart PE150E LOE 990805

Remote site tributary card setting:

When user plugin card in TB1 and TB2, this row will showing TB card data here. User can accoreding the info then press [F2]….. key setting it.

Re is meaning Remote site

Into card parameters setting screen:

86

Page 93: LightSmart PE150E LOE 990805

4-1-12 Performance Monitoring

The performance monitoring screen will show the Aggregate/Dsx1 and Ethernet PM

87

Page 94: LightSmart PE150E LOE 990805

4-1-12.1 Aggregate/Dsx1 Performance Monitoring

Aggr/Dsx1 Performance Monitoring

The performance monitoring screen will show the valid quarters and

valid days had been counted for each channel. Select the channel and

access to next screen to see the detail performance data.

[F6] Reset: to clear all PM counters of the selected channel. [F7] Reset All: to clear all PM counters of all the channels passing [F3],

[F4], and [F5] filter criteria.

88

Page 95: LightSmart PE150E LOE 990805

PM Type have five kinds:

1. CurrQuart(Current Quarter)

2. HistQuart(History Quarter)

3. CurrDay(Current Day)

4. HistDay(History Day)

[F2] Reset: to clear the selected PM type [F5] Reset All: to clear all the PM type

89

Page 96: LightSmart PE150E LOE 990805

4-1-12.2 Trunk Ethernet Performance Monitoring

Tx Counter: TX byte or packet count. This counter is incremented once for every data byte/packet of a transmitted packet.

Rx counter:

RX byte or packet. This counter is incremented once for every data byte of a received and forwarded good packet. RX byte/packet count includes both forwarded and dropped good packets. For mirror RX forwarded packets, if these are not good packets they will not be counted.

Rx Drop counter:

RX drop packet count. Packet drop events could be due to lack of resource, local packet, etc. If the mirror RX function is enabled and the packets are only received by the mirror port, these packets are also included in the mirrored ports drop packet counter. Packet lengths less than 64 bytes are not included.

Rx CRC counter:

RX CRC error packet count. This counter is incremented once for every received packet with a length more than 64 bytes but with a CRC error. Oversize packets are also included in this counter.

Rx Fragment counter:

RX fragment, collision, and undersize packet count. These packet lengths are less than 64 bytes.

90

Page 97: LightSmart PE150E LOE 990805

4-1-13 Path Alarm/State Monitoring

Path Alarm/State Monitoring

This screen shows all of alarm status for all monitoring path. Some

diagnostic testing work will cause alarm occurred, and the status of

loopback (V.54) and PRBS action shown as well. The possible alarm for each interface is:

OE : LOS

Aggregate : LOF/RDI/AIS

E1 : LOS/LOF/RDI/AIS

V35 : LOS

Ethernet : LINK

91

Page 98: LightSmart PE150E LOE 990805

4-1-14 Loopback/V.54 Testing

For the diagnostic purpose, low speed E1 or V.35 data channel and

high speed aggregate signal can be locally loop-backed or remotely

loop-backed.

92

Page 99: LightSmart PE150E LOE 990805

Loopback Testing

There are four types of loopback functions for the E1 Module:

a. Tributary Local Loopback (for each E1 signal) b. Aggregate Local Loopback (for all multiplexed E1 signals) c. Aggregate Remote Loopback (for all multiplexed E1 signals) d. Tributary Remote Loopback. (for each E1 signal)

Users can select whether to diagnose a specific channel or all channels under the loopback / V.54 Testing.

Remote site Local site

a. Tributary Local Loopback: In the Loopback / V.54 Testing screen, select the slot ID which is on the tributary card in the local site, then choose “LoLbk / ANA” item.

b. Aggregate Local Loopback: In the Loopback / V.54 Testing screen,

select the aggregate item (“Aggr/Lo”) in the local site then choose “LoLbk / ANA” item.

c. Aggregate Remote Loopback: In the Loopback / V.54 Testing screen,

select the aggregate item (“Aggr/Re”) in the remote site then choose “ReLbk / DIG” item.

d. Tributary Remote Loopback: In the Loopback / V.54 Testing screen,

select the slot ID which is on the tributary card in the remote site then choose “ReLbk / DIG” item.

※Notice: In the E1 module, the “REM” is not able to choose, because “REM”

is only for V.35 module using.

93

Page 100: LightSmart PE150E LOE 990805

There are three types of loopback functions for the V.35 Module:

a. Analog (ANA) Loopback: b. Digital (DIG) Loopback c. Request Remote (REM) Loopback

V35 card

a. Analog (ANA) Loopback: In the Loopback / V.54 Testing screen, select the slot ID which is on the tributary card in the local site, then choose “LoLbk / ANA” item.

b. Digital (DIG) Loopback: In the Loopback / V.54 Testing screen, select

the slot ID which is on the tributary card in the local site, then choose “ReLbk / DIG” item.

c. Request Remote (REM) Loopback: In the Loopback / V.54 Testing

screen, select the slot ID which is on the tributary card in the local site, and then choose “REM” item.

c.

V35 card

DTE a. b.DTE

OpticalLocal Site Remote Site

94

Page 101: LightSmart PE150E LOE 990805

※ Notice:function key [F8]

If the EOC (embedded channel) had broken such as in the aggregate

remote loopback state then [F8] Undo-AgReLBK can be used to re-build the

EOC channel. But, if optical signal lose, this function won't enable. 95

Page 102: LightSmart PE150E LOE 990805

4-1-15 PRBS Test

Pattern Generate

Pattern Analysis

The pattern of PRBS is 215-1(unframing). Both E1 and V35 are able

to perform this testing.

In order to do the self-test, any E1 data link can be selected to have

a PRBS test. The tested result will be shown in the number of error bit as

well as its error ratio.

※ You can only choose one channel to generate or analysis at the same time.

96

Page 103: LightSmart PE150E LOE 990805

One way PRBS test step:

Ana LightSmart-PE150

GEN

Remote

Local

LightSmart-PE150E

97

Page 104: LightSmart PE150E LOE 990805

The round trip PRBS test function operating step.

※ Please refer to the loopback test function to verify the loopback setting.

When user wants to do the PRBS test, firstly, the remote side needs to

set the loopback path (loop A, Loop B, Loop C) which depends on user’s request. In the local device, which will generate a test pattern to remote device, then local device’s analysis part will receive a test pattern through the loopback path. Eventually, user will get a test result on the screen.

Loopback path A

Remote LightSmart-PE150E

Loopback path B

Loopback path C

Local

Ana LightSmart-PE150E GEN

98

Page 105: LightSmart PE150E LOE 990805

4-1-16 Event Browsing

Clear Ram Log [F4]: clear all history events after the system booting.

Clear Flash Log [F5]: If the event-saving function is being enabled. F5

will clear all history events stored in flash memory.

(Ref: 4-3-12.1 Event Class Processing Configuration /

4-3-12.2 Event Alarm Processing Configuration)

99

Page 106: LightSmart PE150E LOE 990805

4-2 LCD Operating Instructions

LightSmart-PE150E provides an easy way to set the configuration, maintenance, and testing by LCD and button.

The default password for LightSmart-PE150E is a combination of the buttons as below, from left to right:

Button Up Right Down Up

※Note: the password for login in LCD menu can be changed via VT100 setting as

section 4-1-3.11.

Button functions are as follows:

Go back to the upper level of the menu Item select “Enter” key to go to a sub-menu or enable selected action

100

Page 107: LightSmart PE150E LOE 990805

4-2-1 LCD Menu Tree Password: _ _ _ _ (Modify Password refer to 4-3-11)

---System

----Network Service [Site] ----SNMP (ON/OFF) ----TELNET (ON/OFF) ----FTP (ON/OFF) ----WEB (ON/OFF)

----Profile Operation [Site/ProfID]

----Load ----Save

----Reboot Operation [Site]

----Reboot (DOWN)

---Tb Config ----E1 [Site/Slot/Ch]

----FrameType (FAS+CRC/FAS/OFF) ----LineCoding (HDB3/AMI) ----Service (IS/OOS)

----T1 [Site/Slot/Ch] ----FrameType (FAS+CRC/FAS/OFF) ----LineCoding (HDB3/AMI) ----Service (IS/OOS) ----T1 LBO (0-133 ft /133-266 ft /266-399 ft /

399-533 ft /533-655 ft)

----V35 [Site/Slot/Ch] ----TxClkSource (ClkSrc:Internal/Ext-DTE/Recovery) ----PCM/FrameMode (PCM30/PCM31/Unframed) ----DataRate (64K/128K/192K/256K/320K/384K/448k/512k/

576k/640k/704/768K/832K/896K/960K/1024K/

1088K/1152K/1216K/1280K/1344K/1408K/

1472K/1536K/1600K/1664K/1728K/1792K/

1856K/1920K/1984K/2048K) ----TxClkPolarity (Normal/Invert) ----RxClkPolarity (Normal/Invert) ----Service (IS/OOS)

101

Page 108: LightSmart PE150E LOE 990805

----FXX [Site/Slot/Ch] ----Service (IS/OOS)

----TSA [Site]

----TSA (Normal/2E1+2V.35/7E1+1V.35/CH4<->CH5)

---Opt Config [Site] ----Working OE (1/2) ----ALS (ON/OFF) ----Standby OE (ON/OFF) ----APS (ON/OFF)

---Trunk Eth Config ----General Config [Site]

----VLAN (Enable/Disable)

----Port Config [Site] ----Service (IS/OOS) ----AutoNeg (ON/OFF) ----Duplex (Full/Half) ----Speed (10M/100M) ----FlowCtrl (ON/OFF)

---Data Port Config [Site] ----Baud Rate(115200/57600/38400/19200/9600) ----Data Bit(8/7/6/5) ----Parity(Disable/Even/Odd) ----Stop Bit(1 bit/ 1.5 bit/ 2 bit)

102

Page 109: LightSmart PE150E LOE 990805

---Oe Protect Sw ----Current Status [Site]

----WorkingOe (Status:1/2) ----OELocked (Status:-/ON/OFF) ----SwitchNo (Status:1-99) ----LeftRelSec (Status:1-99999) ----OE1Tx (Status:ON/OFF) ----OE2Tx (Status:ON/OFF)

---Oe Lock/Release [Site] ----Lock OE

(Status:(ON)/Release OE(DOWN)) ----Lock OE

(Status:(OFF)/Lock OE(DOWN))

---Oe Restart [Site/Oeld] ----Restart DOWN

(Restart OK/ Restart fail)

---Oe Test [Site/Oeld] ----RestartTest DOWN

(RestartTest OK/ RestartTest fail)

---FM Config ----Pwr Fail Mon Cfg [Site/ PwrID]

----Service Config (IS/OOS)

---Alarm Monitoring ----Equipment [Site]

----Pwr1 (Status:NoAlarm/Failed) ----Pwr2 (Status:NoAlarm/Failed) ----Fan (Status:NoAlarm/Failed)

----Path [Site] ----Alarm (Next)

103

Page 110: LightSmart PE150E LOE 990805

--- Loopback/V.54[Site] ---- Aggr

----LLBK (ON/OFF) ----RLBK (ON/OFF) ----RRLBK (ON/OFF) ----UndoAgReLBK (ON/OFF)

----E1 [Slot/Ch]

---LLBK (ON/OFF) ---RLBK (ON/OFF)

---- T1 [Slot/Ch]

----LLBK (ON/OFF)

----RLBK (ON/OFF)

---- V.35 [Slot/Ch]

----ANA (ON/OFF)

----DIG (ON/OFF)

----REM (ON/OFF)

--- PRBS Testing[Site] ---- E1 [Slot/Ch]

----PTGEN (ON/OFF) ----PTANA (ON/OFF) ----PTANA Result (Status:Error/BER)

----T1 [Slot/Ch]

----PTGEN (ON/OFF) ----PTANA (ON/OFF) ----PTANA Result (Status:Error/BER)

----V.35 [Slot/Ch]

----PTGEN (ON/OFF) ----PTANA (ON/OFF) ----PTANA Result (Status:Error/BER)

--- Logout (DOWN)

104

Page 111: LightSmart PE150E LOE 990805

4-3 Web Operating Interface

To be able to use the WEB interface, the IP must be enabled and configured via the command line interface.

(Please reference 4-1-3.2 device networking configuration, Page.17)

※ The default user Name is admin and the password is 1234 (Reference 4-1-3.3 User Account Managment, Page.18)

105

Page 112: LightSmart PE150E LOE 990805

Login screen will show the equipment status.

Only local side:

Local side and Remote side:

106

Page 113: LightSmart PE150E LOE 990805

User can chose display the Local site, Remote site or Local+Remote.

If the profile had been changed before during the configuration processing, the “Blue Title” will show “Config Modified”. You can select “Profile Management”, chose save profile I or II.

107

Page 114: LightSmart PE150E LOE 990805

4-4 Telnet Operating

Using RJ-45 connecting to SNMP management system. To be able to

use the telnet interface, the device IP must be setting first.

※ The default user Name is admin and the password is 1234

108

Page 115: LightSmart PE150E LOE 990805

Appendix

A-1 Carft & External Alarm Ports Pin Assignment

1. Craft port (VT100):

5 4 3 2 1

Pin No. Signal 2 TxD 3 RxD 5 GND

2. Alarm port:

Pin No. Signal 1 2 RMIN LEDA 3 RMIN BUA 4 RMAJ LEDA 5 RMAJ BUA 6 RMIN LEDB 7 RMIN BUB 8 RMAJ LEDB 9 RMAJ BUB

5 4 3 2 1

9 8 7 6

109

Page 116: LightSmart PE150E LOE 990805

3. External alarm port:

Pin No. Signal

1 Positive input Port1

8 Negative input 4 Positive input Port2 9 Negative input 9 8 3 6

5 4 3 2 1

The voltage offset between positive and negative input: 3 ~ 60VDC Input current range: 0.5 ~ 8 mA

A-2 Pin Assignment for Tributary T1 pad

Ch1 Ch2 Ch3 Ch4 GND

Rx

Tx

110

Page 117: LightSmart PE150E LOE 990805

A-3 DB25 Pin Assignment for Tributary T1 Line Connection

CH1 CH2 CH3 CH4 24 21 18 15

Rx 25 22 19 16 11 8 5 2

Tx 12 9 6 3

111

Page 118: LightSmart PE150E LOE 990805

A-4 Troubleshooting Guide

No. Symptom Probable Cause Corrective Actions 1. VT-100 can not login CIT cable connection invalid.

Baud Rate set incorrect and com port select incorrectly Input wrong account aud password

Check cable link. Check Baud Rate and com port Check account and password

2. The equipment screen alarm indicators are different from physical indicators or like network hang

Check relation configuration and physical connector

User can via into tributary slot parameters configuration and trunk Ethernet parameters configuration screen check every item: Check service mode Ethernet port contact Change the Ethernet cable Check the duplex matching

3. Ethernet transmit has serious data package loss

The RJ45 connector has a bad contact FULL/HALF duplex is not matching Trunk Ethernet port service off

Check the duplex matching Check Auto-neg mode Check Data forwarding mode Check Trunk Ethernet port all configuration function

4. Ping fail or can’t transfer data or can not remote Telnet

Trunk Ethernet port service off Fiber fail The RJ45 connector has a bad contact Networking service management telnet function to be off Trunk Ethernet general parameters setting error

Check the duplex matching Check Trunk Ethernet port all configuration function Check the fiber contact Change optical cable Check networking service

management function. Into diagnostic&loopback test item: (service mode must be on)

Execute Autolbk to check optical connection

5. The unit is reset or powered off, all the configuration settings are lost

The user wrong to select save configuration or select incorrect loading profile.

This equipment will according your last time startup state to loading the profile.

If your last time is loading factory default value, when you restart unit, it will loading factory default .

6. Device can not be management

Networking service management snmp function to be off Device IP incorrect SNMP agent configuration : read/write community incorrect

Check networking service management Check device IP Check snmp agent configuration

7. Power indicator is off Power supply is not available The switch of the power supply is

not open The connect of the power supply is

not tight

Change the power supply Open the switch of the power

supply Screw down the power supply

112

Page 119: LightSmart PE150E LOE 990805

No. Symptom Probable Cause Corrective Actions 8. Optical LOS alarm

indicators is on If self loop of the optical ports is

normal and the connection of the optical cables is right, the optical cables has trouble or the distance is too long

Otherwise the TX and RX optical interface connection is reverse

Change the optical cables Change a long distance optical

module Exchange the TX and RX fiber

cables 9. The equipment of One

side of the optic connection is normal, and other has LOS alarm

Self loop separately, the equipment that has LOS alarm has trouble

Otherwise the RX fiber cable has trouble

Contact with your support representative

Change the optical cables

10. T1 interface alarms T1 cable connector has trouble The T1 equipment is powered off The T1 TX and RX interface

connection is reverse

Adjust the connector Open the T1 equipment that

connect to the unit Exchange the TX and RX

interface connectors 11. V.35 interface alarms Clock settings do not match

The V.35 connector has a bad contact

Check V.35 interface configured

12. OE module can’t not switching

Check OE module whether startup lock function.

Check Optical interface parameters config

Check OE switching protection status

13. Prbs test showing error bit or test is ok but always showing red indicators.

Not comply use framing in unframed type.

The user lookup prbs test result at wrong place

Configured correct type in unframed.

In general ,user should be check the result in prbs testing screen.

14 LCD key can not login and setting

Check input key priority button is correct.

Check console screen item “LCD Login Configuration “ whether it has redefine.

Check “LCD Login Configuration”.

15 T1 interfaces have bit errors

Impedance is not matching T1 cables is too long The T1 connector has a bad contact100Ω connect cable is not twisted T1 terminal unit is not common

earthing with the optical multiplexer

Affirm the impedance of the T1 equipment is same of the optical multiplexer

Affirm the distance of the T1 cable is no longer than 200 meters

Adjust the T1 connector Affirm the 1,2 pin of the RJ45

(120Ω) is twisted, and the 4,5 pin is another twisted

Affirm the earthing of the T1 terminal unit and the optical multiplexer is according to the electrician standard

113