Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church...

18
Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences

Transcript of Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church...

Page 1: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Lighting Retrofit Initiative

Steve Bodkin

Director, Engineering & Energy Management

National Church Residences

Page 2: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

National Church Residences

Christian Based Company

Nation’s largest non-profit providing affordable housing for the vulnerable: low and moderate income seniors, families, persons with disabilities, and formerly

homeless

Page 3: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

National Church Residences

Over 300 properties

In 30 states

22,000 residents

Page 4: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

National Church Residences

Lighting Retrofit Initiative

Page 5: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Secure Internal Buy-in

Scope Common area (halls, staircases, office, community rooms,

rest rooms, etc.) Tenant units – possible ceiling fluorescent in kitchen

Process Property lighting survey Property lighting audit Approval process Installation

Payback: < 5 years

Page 6: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Complete On-line Property Survey: ZoomerangPurpose is to target properties Internal hallways and stairwells w/ 24x7

lighting Incandescent and / or T12 fluorescent tubes

Hallways Stairwells Office Community room Common area rest rooms

NCR Properties308

167

0

50

100

150

200

250

300

350

Total Target

Page 7: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Request for Business

Nation-wide scope and list price by fixture/bulb Use of standard lighting audit spreadsheet Lamp specifications Quality of work standards Cleanliness of work Communication and coordination of work Performance requirements Recycling / disposal of lamps

Page 8: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Request for Business: List Pricing

Page 9: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Lighting Vendor Install Cost Comparison

$0

$50

$100

$150

$200

$250

$300

$350

$400

RE

TR

O 2

',1L,

F17

T8,

LPE

B

RE

TR

O 2

',1L,

F15

T8,

LPE

B

RE

TR

O 2

',2L,

F17

T8,

LPE

B

RE

TR

O 2

',3L,

F17

T8,

LPE

B

RE

TR

O 2

',4L,

F17

T8,

LPE

B

RE

TR

O 2

',1L,

F17

T8/

841,

SP

EB

,RE

F

RE

TR

O 2

',2L,

F17

T8/

841,

SP

EB

,MIR

RO

RE

F

RE

TR

O 2

',2L,

F17

T8/

741,

LPE

B,M

IRR

O R

EF

RE

TR

O 2

',3L,

F17

T8/

741,

LPE

B,M

IRR

O R

EF

RE

TR

O 2

',2L,

F17

T8/

741,

LPE

B,W

hite

RE

F

RE

TR

O 2

',2L,

FB

32T

8 U

-TU

BE

,LP

EB

,

RE

TR

O 2

',1L,

FB

32T

8 U

-TU

BE

,LP

EB

,

RE

TR

O 2

',3L,

F17

T8/

841,

SP

EB

,MIR

RO

. RE

F

RE

TR

O 2

',3L,

F17

T8/

841,

SP

EB

,Whi

te R

EF

RE

TR

O 2

',2L,

F17

T8/

841,

SP

EB

,RE

F

RE

TR

O 2

',3L,

F17

T8/

841,

SP

EB

,RE

F

RE

TR

O 2

',2L,

F17

T8/

841,

SP

EB

,RE

F

RE

TR

O 3

',1L,

F25

T8,

LPE

B

RE

TR

O 3

',2L,

F25

T8,

LPE

B

RE

TR

O 3

',2L,

F25

T8,

LPE

B w

/ tan

dem

bal

last

RE

TR

O 3

',3L,

F25

T8,

LPE

B

RE

TR

O 3

',4L,

F25

T8,

LPE

B

RE

TR

O 4

',1L,

F32

T8,

LPE

B

RE

TR

O 4

',1L,

F32

T8,

LPE

B,W

HIT

E R

EF

RE

TR

O 4

',2L,

F32

T8,

LPE

B

RE

TR

O 4

',2L,

F32

T8,

Dim

min

g LP

EB

RE

TR

O 4

',2L,

F32

T8,

LPE

B,M

IRR

O R

EF

RE

TR

O 4

',2L,

F32

T8,

LPE

B,W

hite

RE

F

RE

TR

O 4

',3L,

F32

T8,

LPE

B

RE

TR

O 4

',2L,

F32

T8/

EB

,MIR

RO

RE

F

RE

TR

O 4

',2L,

F32

T8/

841,

Dim

min

g S

PE

B,R

EF

RE

TR

O 4

',4L,

F32

T8,

LPE

B

RE

TR

O 4

',2L,

F32

T8,

EB

,MIR

RO

RE

F

RE

TR

O 4

',6L,

F32

T8,

LPE

B

RE

TR

O 6

',2L,

F25

T8,

LPE

B,C

ON

V K

IT

RE

TR

O 6

',2L,

F72

T12

,SP

EB

RE

TR

O 6

',4L,

F25

T8,

LPE

B,C

ON

V K

IT

RE

TR

O 8

',2LF

32T

8,LP

EB

RE

TR

O 8

',2LF

32T

8,D

imm

ing

LPE

B

RE

TR

O 8

',4LF

32T

8,LP

EB

RE

TR

O 8

',1L,

F96

T8,

SP

EB

RE

TR

O 8

',2LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',2LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',2L,

F96

T8,

SP

EB

RE

TR

O 8

',4LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',4LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',3L,

F96

T8,

SP

EB

RE

TR

O 8

',6LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',4L,

F96

T8,

SP

EB

RE

TR

O 8

',8LF

32T

8,LP

EB

,CO

NV

KIT

RE

TR

O 8

',2L,

F32

T8,

LPE

B,M

IRR

O R

EF

NE

W 4

' 1L

WR

AP

FIX

TU

RE

, F32

T8

NE

W 8

' 4L

WR

AP

FIX

TU

RE

, F32

T8

NE

W 4

' 2L

WR

AP

FIX

TU

RE

, F32

T8

BA

TT

ER

Y B

AC

KU

P B

ALL

ST

S -

B10

0, fo

r F

32T

8 la

mps

1X4,

2X2

PR

ISM

AT

IC D

IFF

US

ER

2X4

PR

ISM

AT

IC D

IFF

US

ER

11W

CF

SC

RE

W-I

N, 1

-PIE

CE

13W

CF

SC

RE

W-I

N, 1

-PIE

CE

19W

CF

SC

RE

W-I

N, 1

-PIE

CE

23W

CF

SC

RE

W-I

N, 1

-PIE

CE

23W

CF

SC

RE

W-I

N, 1

-PIE

CE

w/ m

og-m

ed a

dapt

er

2 x

13W

CF

SC

RE

W-I

N, 1

-PIE

CE

3 x

13W

CF

SC

RE

W-I

N, 1

-PIE

CE

4 x

13W

CF

SC

RE

W-I

N, 1

-PIE

CE

New

13w

CF

L F

ixtu

re

19W

CF

SC

RE

W-I

N, 1

-PIE

CE

, WIT

H P

AR

38 L

EN

S A

ND

RE

FLE

CT

OR

Exi

t Lig

ht,L

ED

,pla

stic

, 90

Min

ute

Bat

tery

Bac

kup,

1 s

ide

Exi

t Lig

ht, L

ED

, pla

stic

, 90

Min

ute

Bat

tery

Bac

kup,

2 s

ide

Exi

t and

Em

erge

ncy

Ligh

t Com

bo,L

ED

,pla

stic

, 90

Min

ute

Bat

tery

Bac

kup,

1 s

ide,

2 e

mer

genc

y lig

hts

Exi

t and

Em

erge

ncy

Ligh

t Com

bo,L

ED

,pla

stic

, 90

Min

ute

Bat

tery

Bac

kup,

2 s

ide,

2 e

mer

genc

y lig

hts

Exi

t Lig

ht,L

ED

,die

cas

t met

al, 9

0 M

inut

e B

atte

ry B

acku

p, 1

sid

e

Exi

t Lig

ht, L

ED

, die

cas

t met

al, 9

0 M

inut

e B

atte

ry B

acku

p, 2

sid

e

Exi

t and

Em

erge

ncy

Ligh

t Com

bo,L

ED

,die

cas

t met

al, 9

0 M

inut

e B

atte

ry B

acku

p, 1

sid

e, 2

em

erge

ncy

light

s

Exi

t and

Em

erge

ncy

Ligh

t Com

bo,L

ED

,die

cas

t met

al, 9

0 M

inut

e B

atte

ry B

acku

p, 2

sid

e, 2

em

erge

ncy

light

s

LED

HA

RD

WIR

E K

IT

Ins

tall

ed

Un

it C

os

t

Vendor 1

Vendor 2

Vendor 3

Fluorescent Tubes & Ballast Retrofit CompactFluorescent

Lamps

Exit

Page 10: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Completion of Property Lighting Audits Detailed count of each type of bulb / fixture Cost based on retrofit and list pricing Savings based on lamp / ballast specification,

operating hours, and utility costs Completion of report in standard spreadsheet format

Unit list pricing Cost Savings Payback Executive summary

Page 11: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Unit Pricing

Page 12: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Cost Detail

Page 13: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Savings Detail

Monthly kW Savings: 21.56; Annual kWh Savings: 72,144

Page 14: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Payback

Page 15: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Executive Summary

Page 16: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Lighting Retrofit Implementation

NCR Properties308

167

100

0

50

100

150

200

250

300

350

Total Target 5-Year Payback

Page 17: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Actual Consumption Projected SavingsLighting Retrofit Preliminary Savings Analysis

0

10000

20000

30000

40000

50000

60000

70000

80000

90000

100000

Riverv

iew M

anor

Decat

ur V

illage

Frank

lin H

ouse

Shale

r Oak

s

Autum

n Gro

ve

Oak C

reek

Villa

ge

Quinb

y Par

k Apa

rtmen

ts

Solom

on h

eigh

ts

Kears

arge

Plac

e

Highlan

ds m

anor

Coles L

andin

g

Courtn

ey

Crestv

iew T

erra

ce

Parks

ide M

anor

Sandp

iper

Run

Apple

Blos

som

Plac

e

Hickor

y Gro

ve

Gable

Ridg

e

Barne

sville

Man

or

Reser

ve a

t Ind

ian H

ill

Property

Consumption in Kw/hr Actual

Performance

EstimatedSavings

Page 18: Lighting Retrofit Initiative Steve Bodkin Director, Engineering & Energy Management National Church Residences.

Estimated Impact of Lighting Retrofit

Carbon reduction of Carbon reduction of 6.2 million lbs / year6.2 million lbs / year

Same asSame as 130,000 mature trees130,000 mature trees Emissions from 44 Emissions from 44

cars cars

Environmental

Cost: $1.2 millionCost: $1.2 million

Savings: $320k/YrSavings: $320k/Yr

Payback: 3.6 YrsPayback: 3.6 Yrs

Financial