LIGHT COMMERCIAL BOILERS LIGHT COMMERCIAL

Transcript of LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425...

Page 1: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

LIGHTCOMMERCIAL

BOILERS

LIGHT COMMERCIAL

Page 2: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

INTRODUCTION

Portrait of a market leaderin a steady growth

IMMERGAS: NOw AvAILABLE IN 30 COUNTRIESImmergas presence on the international market has been increasing year after year. Today the brand is available in more than 30 countries; the company structure includes 9 branches in Europe and one in China, as well as shares in significant import firms all around the world.Immergas is deeply investing in promotion and communication, with the aim of supporting the brand and penetrating new markets. From Asia to South America the company is steadily expanding, with a policy based on quality, vanguard products and accurate service.

Immergas is the leading company in the Italian market of gas heating boilers. In the headquarters of Brescello work more than 700 people, spread over an area of 50,000 sq.m.In 2008 Immergas sold more than 300.000 appliances; the turnover was 240 million euro, more than 55% of which on the international market.The range of products is continuously widening, in order to satisfy all marketrequests. At the moment Immergas offers more than 70 models, wall-mounted or floor standing, instantaneous, for outdoor installation, condensing, with sealed chamber.An extremely wide choice with a common characteristic: the research for reliability, long-life, convenience.

22

Page 3: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

INTRODUCTION

LOw EMISSIONS ANDECO-fRIENDLy PRODUCTS: PLANET EARTH SAyS THANkSImmergas pays great attention to nature and environment. Our Research and Development Department is more and more eco-oriented: this investment in terms of staff and resources is our contribution to make the world a cleaner space.When projecting new models, the search for energy saving is always the main issue, in order to reduce energy consumption and pollutant emissions. In Italy, Immergas is leader in the segment of condensing boilers, which offer up to 30% energy saving as compared to traditional ones.

CONDENSE AND ENjOyA condensing boiler is an eco-friendly boiler. The special burner allows to lower pollutant emissions such as carbon monoxide (CO) and nitrogen oxides (NOx), two of the main responsible of air pollution. In fact, condensing boilers belong to class 5, the most environment-friendly class established by the European standards (UNI EN 297 e UNI EN 483).Condensing boilers have an advanced modulating system which can perfectly adjust the heat output to the real needs of the heating system. The modulating range, wider than in traditional boilers, ensures the right comfort and wellness inside the house, in all different climatic situations throughout the year.

3

Page 4: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

INTRODUCTION

.01

10 kW 920 kW

POwER: fROM 10 UP TO 920 kw!Light commercial VICTRIX range is composed by wall-hung condensing boilers with heat outputs from 50 to 115 kW, designed by Immergas to satisfy different kinds of installation exigencies.The high efficiency ratings achieved are ideal when it comes to heating large volumes domestic systems (such as semi-detached houses or apartment blocks) and for commercial and industrial uses.Light commercial VICTRIX models are heating only appliances, pre-engineered to operate both as single appliances or in cascade, with the advantage of providing a globally higher efficiency at lower running costs.The wide modulation range characterizing the light commercial VICTRIX models and the possibility to manage up to a maximum of 8 appliances in cascade, allow to obtain great flexibility in the offer of the available heat outputs.

.01

Modulating range

4

Page 5: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

THE CASCADE SySTEMThe cascade system consists in the installation of two or more modular generators in parallel, connected to a control system regulating its functioning as if it was a single appliance.The total heat output is equal to the sum of each single generator output.Distributing the heat output on more than one unit brings many important advantages:

Higher efficiency compared with the use of a single generator of great heat output, which would have to work with a reduced heating load for a good part of the heating period, with consequent general lower efficiency.

Less expenses thanks to the better efficiency.

Greater safety as the subdivision in more units allows to maintain the heating function active even in case of maintenance on one of the connected appliances.

Greater flexibility with the possibility of distributing the heating request on all the appliances, while the functioning sequence avoids the fast deterioration of one boiler respect the other.

INTRODUCTION

Maximum heat output

.02

.02

Example of cascade functioning

Minimum heat output

Reduced heat output

Medium heat output

5

Page 6: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

.03

INTRODUCTION

Cascade and zones regulator Zone manager Modulating room thermostat

CASCADE AND zONES REGULATORCentral unit of the thermoregulation system, it allows to control, monitor and program the operating sequence of a maximum of 8 generators in cascade. The regulator controls the boiler’s delivery temperature adjusting it to the system requirements.The regulator can manage up to 3 different zones (2 of which at high/low temperature) and a sanitary circuit for a separate storage tank. It is also possible to install up to 5 regulators in parallel (of which only one, called master, will be connected to the generators) to control up to a maximum of 15 heating zones and 5 storage tanks for the domestic hot water production.

.03

THE THERMOREGULATION SySTEMAll light commercial VICTRIX boilers are provided with new generation electronics, offering the best performances thanks to their regulation flexibility. In case of zones systems or cascade systems, it will be necessary to pre-arrange an adequate thermoregulation device able to manage every single appliance and elaborate the information from the system, in order to meet the most varied operating requirements.

.04 .05

zONE MANAGERConnected to the cascade and zones regulator, it allows to keep the operating appliance and the heating system information handy and under control. This means that the previously set functioning parameters (turn on/off, temperatures, etc.) can be easily modified by the user, without having to operate on the central regulator.

.04

ExTERNAL PROBEConnected to the boiler, it allows to optimize the energy consumptions automatically adjusting the system delivery temperature to suit the outdoor temperature variations.

SySTEM DELIvERy PROBEIt allows the cascade and zones regulator to manage the system temperature.

SEPARATE STORAGE TANk PROBEIt allows the cascade and zones regulator to control the temperature of a separate storage tank.

.05 MODULATING ROOM THERMOSTATConnected to the cascade and zones regulator, it allows the user to regulate the room temperature of the single zones into which the system is divided.

6

Page 7: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

Hydraulic manifolds flue systems

INTRODUCTION

Thermoregulation kits

Solar collectors

IMMERSTOR storage tanks

THE COMPLETE PACkAGEIn addition to the light commercial VICTRIX boilers, Immergas offers a series of kits, specially thought and designed to simplify the project and installation of a heating system.

7

Page 8: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 115Wall-hung condensing boiler for heating only

THE RANGE

NEw

8

Page 9: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

THE RANGE

ModelCodeL.G.

L.P.G.

Heat output

kw

Efficiency rating

(D.P.R. 660/96)

Condensing/ premixed

burner

Reduced pollutantemissions(NOx-CO)

Protection index

frostprotection

vICTRIx 115 3.0204263.020426GPL

109,0 4 stars • • IPX5D -5 °C

Main options Code

External sensor 3.015266

Three-way valve kit 3.015223

Hydraulic manifold kit 3.015224

Main flue kits Code

Terminal horizontal outlet kit Ø 80 3.015255

Terminal vertical outlet kit Ø 80 3.015256

Horizontal concentric kit Ø 80/125 3.015242

For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.

Model Height width Depth

vICTRIx 115 1010 mm 600 mm 610 mm

vICTRIx 115Open chamber fan assisted wall-hung condensing boiler for heating only, equipped with circulator and safety valve.The boiler is approved for installation in both indoor heating plants and outside buildings, without requiring additional protection. It can be installed as single appliance or in cascade.The generator is equipped with electronic board, allowing to adjust the functioning parameters of the appliance to the specific exigencies of every single system.

Nominal heat output of 109 kW

Minimum heat output of 29 kW

Compact dimensions

Stainless steel condensing module

4 bar safety valve with discharge funnel

Double NTC probe for optimum temperature control

IPX5D protection index

Frost protection up to -5 °C

Control board with visual display

Autodiagnosis system

Possibility to connect a separate storage tank unit

0051BO2448 9

Page 10: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 90Wall-hung condensing boiler for heating only

THE RANGE

NEw

10

Page 11: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 90Open chamber fan assisted wall-hung condensing boiler for heating only, equipped with circulator and safety valve.The boiler is approved for installation in both indoor heating plants and outside buildings, without requiring additional protection. It can be installed as single appliance or in cascade.The generator is equipped with electronic board, allowing to adjust the functioning parameters of the appliance to the specific exigencies of every single system.

Nominal heat output of 90 kW

Minimum heat output of 22,5 kW

Compact dimensions

Stainless steel condensing module

4 bar safety valve with discharge funnel

Double NTC probe for optimum temperature control

IPX5D protection index

Frost protection up to -5 °C Control board with visual display

Autodiagnosis system

Possibility to connect a separate storage tank unit

ModelCodeL.G.

L.P.G.

Heat output

kw

Efficiency rating

(D.P.R. 660/96)

Condensing/ premixed

burner

Reduced pollutantemissions(NOx-CO)

Protection index

frostprotection

vICTRIx 90 3.0204253.020425GPL

90,0 4 stars • • IPX5D -5 °C

Main options Code

External sensor 3.015266

Three-way valve kit 3.015223

Hydraulic manifold kit 3.015224

Main flue kits Code

Terminal horizontal outlet kit Ø 80 3.015255

Terminal vertical outlet kit Ø 80 3.015256

Horizontal concentric kit Ø 80/125 3.015242

For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.

Model Height width Depth

vICTRIx 90 1010 mm 600 mm 610 mm

THE RANGE

0051BO2448 11

Page 12: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 75Wall-hung condensing boiler for heating only

THE RANGE

12

Page 13: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

THE RANGE

0051BO2448

ModelCodeL.G.

L.P.G.

Heat output

kw

Efficiency rating

(D.P.R. 660/96)

Condensing/ premixed

burner

Reduced pollutantemissions(NOx-CO)

Protection index

frostprotection

vICTRIx 75 3.0185113.018511GPL

72,6 4 stars • • IPX5D -5 °C

Main options Code

External sensor 3.015266

Three-way valve kit 3.015223

Hydraulic manifold kit 3.015224

Main flue kits Code

Terminal horizontal outlet kit Ø 80 3.015255

Terminal vertical outlet kit Ø 80 3.015256

Horizontal concentric kit Ø 80/125 3.015242

For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.

vICTRIx 75Open chamber fan assisted wall-hung condensing boiler for heating only, equipped with circulator and safety valve.The boiler is approved for installation in both indoor heating plants and outside buildings, without requiring additional protection. It can be installed as single appliance or in cascade. The generator is equipped with electronic board, allowing to adjust the functioning parameters of the appliance to the specific exigencies of every single system.

Nominal heat output of 72,6 kW

Minimum heat output of 18 kW

Compact dimensions Stainless steel condensing module

4 bar safety valve with discharge funnel

Double NTC probe for optimum temperature control

IPX5D protection index

Frost protection up to -5 °C

Control board with visual display

Autodiagnosis system

Possibility to connect a separate storage tank unit

Model Height width Depth

vICTRIx 75 950 mm 600 mm 525 mm

13

Page 14: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 50Wall-hung condensing boiler for heating only

THE RANGE

14

Page 15: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

THE RANGE

vICTRIx 50Open chamber fan assisted wall-hung condensing boiler for heating only, equipped with circulator and safety valve.The boiler is approved for installation in both indoor heating plants and outside buildings, without requiring additional protection. It can be installed as single appliance or in cascade. The generator is equipped with electronic board, allowing to adjust the functioning parameters of the appliance to the specific exigencies of every single system.

Nominal heat output of 50 kW

Minimum heat output of 10 kW

Compact dimensions

Stainless steel condensing module

4 bar safety valve with discharge funnel

Double NTC probe for optimum temperature control

IPX5D protection index

Frost protection up to -5 °C Control board with visual display

Autodiagnosis system

Possibility to connect a separate storage tank unit

ModelCodeL.G.

L.P.G.

Heat output

kw

Efficiency rating

(D.P.R. 660/96)

Condensing/ premixed

burner

Reduced pollutantemissions(NOx-CO)

Protection index

frostprotection

vICTRIx 50 3.0163593.016359GPL

50,0 4 stars • • IPX5D -5 °C

Main options Code

External sensor 3.015266

Three-way valve kit 3.015223

Hydraulic manifold kit 3.015224

Main flue kits Code

Terminal horizontal outlet kit Ø 80 3.015255

Terminal vertical outlet kit Ø 80 3.015256

Horizontal concentric kit Ø 80/125 3.015242

Model Height width Depth

vICTRIx 50 950 mm 600 mm 525 mm

For good performance and safe operation use Immergas “Green Series” pipes and terminal flue outlet only.

0051BO2448 15

Page 16: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

vICTRIx 115/90

keyElectrical connectionSystem deliveryCondensate drainGas supplySystem return

VMSCGR

Hydraulic connections

Gas Heating Condensate drain

G R M SC

VICTRIX 115 1” 1 ½” 1 ½” 13 mm

VICTRIX 90 ¾” 1 ½” 1 ½” 13 mm

Horizontal concentrickit Ø 80/125

at top speed with single boiler

at second speed with single boiler

at top speed with non return valve for boilers in cascade

at second speed with non return valve for boilers in cascade

Available head in the system:

Horizontal outletkit Ø 80

Hea

d (k

Pa)

Flow rate (l/h)

Hea

d (m

H O

)2

Hea

d (k

Pa)

Flow rate (l/h)

Hea

d (m

H O

)2

300 300

ø80 140

1086

1010

982

905

134

253

315

340

610

SC

G

390 105105

70V

M R

TECHNICAL DATA

vICTRIx 115 flow rate/head graph

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

110

100

90

80

70

60

50

40

30

20

10

0

11.22

10.20

9.18

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

0

90

80

70

60

50

40

30

20

10

0

9.18

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200

Dimensions and connections

vICTRIx 90 flow rate/head graph

Quota kit orizzontale tiraggio forzato Ø 80

Quota kit orizzontalecoassiale Ø 80/125

Quota kit orizzontale tiraggio forzato Ø 80

Quota kit orizzontalecoassiale Ø 80/125

190

136

160

110

16

Page 17: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

keyElectrical connectionSystem deliveryCondensate drainGas supplySystem return

VMSCGR

Hydraulic connections

Gas Heating Condensate drain

G R M SC

¾” 1 ½” 1 ½” 13 mm

Horizontal concentrickit Ø 80/125

Horizontal outletkit Ø 80

at top speed with single boiler

at second speed with single boiler

at top speed with non return valve for boilers in cascade

at second speed with non return valve for boilers in cascade

Available head in the system:

ø 80 232

1010

950

905

70

150

105 105390

600

190

220

285

525

SC

V

G

M R

TECHNICAL DATA

Hea

d (k

Pa)

Hea

d (m

H O

)2

Flow rate (l/h)

Hea

d (k

Pa)

90

80

70

60

50

40

30

20

10

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800

9.18

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

0

Hea

d (m

H O

)2

90

80

70

60

50

40

30

20

10

0

Flow rate (l/h)0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600

9.18

8.16

7.14

6.12

5.10

4.08

3.06

2.04

1.02

0

vICTRIx 75/50

Dimensions and connections

vICTRIx 75 flow rate/head graph vICTRIx 50 flow rate/head graph

Quota kit orizzontale tiraggio forzato Ø 80

Quota kit orizzontalecoassiale Ø 80/125

Quota kit orizzontale tiraggio forzato Ø 80

Quota kit orizzontalecoassiale Ø 80/125

200

136

170

110

17

Page 18: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

Unit ofmeasurement vICTRIx 50 vICTRIx 75 vICTRIx 90 vICTRIx 115

Maximum nominal heat input kW 50,8 74,6 92,3 110,7

Minimum nominal heat input kW 10,4 18,5 23,0 29,4

Maximum nominal heat output (80/60 °C) kW 50,0 72,6 90,0 109,0

Maximum nominal heat output (40/30 °C) kW 54,4 79,8 100,3 120,3

Minimum nominal heat output (80/60 °C) kW 10,0 18,1 22,5 28,8

Efficiency at nominal heat output (80/60 °C) % 98,5 97,3 97,5 98,4

Efficiency at minimum heat output (80/60 °C) % 96,0 97,6 97,8 98,0

Efficiency at nominal heat output (50/30 °C) % 106,0 104,5 106,0 106,9

Efficiency at minimum heat output (50/30 °C) % 106,5 106,3 108,2 108,2

Efficiency at nominal heat output (40/30 °C) % 107,0 107,0 108,7 108,7

Efficiency at minimum heat output (40/30 °C) % 107,0 107,0 109,1 109,6

Stack losses with burner on % 1,3 2,3 1,8 1,8

Stack losses with burner off % 0,02 0,01 0,01 0,01

Casing losses with burner on % 0,2 0,4 0,7 0,2

Casing losses with burner off % 0,47 0,32 0,41 0,28

Gas consumption at nominal heat output with natural gas

m3/h 5,37 7,90 9,77 11,72

Fumes temperature at max. nominal heat input °C 41 62 52 52

Fumes temperature at min. nominal heat input °C 47 48 49 45

Fumes flow rate at max. nominal heat input kg/h 81 120 148 175

Fumes flow rate at min. nominal heat input kg/h 17 31 38 49

CO2 at maximum heat input % 9,3 9,2 9,3 9,45

CO2 at minimum heat input % 9,2 8,9 9,1 8,95

CO at maximum heat input with 0% of O2 ppm 130 170 180 175

CO at minimum heat input with 0% of O2 ppm 5 7 10 8

NOx at maximum heat input with 0% of O2 mg/kWh 69 53 37 49

NOx at minimum heat input with 0% of O2 mg/kWh 28 28 14 20

Weighted CO mg/kWh 37,6 43,0 20,0 19,0

Weighted NOx mg/kWh 38,5 40,0 23,3 28,0

NOx class - 5 5 5 5

Central heating temperature range °C 20–85 20–85 25–85 25–85

Maximum heating temperature °C 90 90 90 90

Maximum operating pressure bar 4,4 4,4 4,4 4,4

Available head with 1000 l/h flow rate kPa 55,4 65,5 87,7 92,18

Dimensions

Height mm 950 950 1010 1010

Width mm 600 600 600 600

Depth mm 525 525 610 610

Electrical supply V/Hz 230/50 230/50 230/50 230/50

Nominal power draw A 0,85 1,26 1,69 1,80

Installed electric power W 180 270 370 390

Fan power consumption W 59 72 102 117

Circulator power consumption W 115 168 238 242

Protection index IP X5D X5D X5D X5D

Boiler water content litres 3,7 4,0 10,1 11,7

Full appliance weight Kg 66 72 107 117,2

TECHNICAL DATA

18

Page 19: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

VICTRIX 115/90 main dimensions and connections

1851

220 222 390

200

169

182

385

905

170

110

G

”3 / 4

G 1 ”

G 1”

G 1

1/2

G 1 ”1/2

G 2 ”1/2G 2 ”1/2

2035

140

610

253251

110

160

390

200

982

395

184

170

G 2

1 / 2

G 2 ”

G 1

G 1 ”

1/2

G 1 ”1/2

G 1 ”1/2

G

3 / 4

SINGLE INSTALLATION

VICTRIX 75/50 main dimensions and connections 19

Page 20: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

Gas supply

System filling

CondensateDrain

2

1

3

12

14

17

13

48

95

6

7

11

10

15

16

22

19

18

20

21

Bla

ck

Ora

nge

Red

1

2

3

45

M

Single generator for room heating and domestic hot water production with storage tank connected to solar panels

ISPESL approved thermometer

ISPESL approved manuallyreset thermostat

ISPESL approved manuallyreset pressure switch

System circulatorExpansion vessel connectionExpansion vesselThree way valveManifold/mixerSludge collecting system filterExternal storage tank unitStorage tank unit probeSolar panel control unitSolar panel circulatorSolar panelSolar panel probe

89

10

111213141516171819202122

keyVICTRIX generatorRoom thermostatExternal probeThermometer trapFuel on-off valve bulbISPESL approved pressure gauge cockFuel on-off valve

1234567

Hydraulic scheme

keyVICTRIX generatorExternal probeStorage tank unit probeRoom thermostatThree way valve

12345

SINGLE INSTALLATION

Electrical schemeSingle generator for room heating and domestic hot water production with storage tank connected to solar panels

20

Page 21: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

CondensateDrain

Gas supply

System filling

ZONE 1(CMI1)

ZONE 2(CMI2)

ZONE 3(CD)

1

2

37 10

12

13

14

11

15 15

20

21

22

25

26

23

27

28 25

29

30

MM

24

16

17

18

19

8

9

4

5

6

ZONE 3 ZONE 1

M M

ZONE 2STORAGE TANK UNIT

Com

mon

Ope

nC

lose

Com

mon

Ope

nC

lose

230 Vac 50Hz

1

15

16

17

18

2

3

4

5

6

7

8

9

10

11

A B A B A B

12 13 13

14

keyZone 3 direct circuit pump (CD)Storage tank unit supply pumpStorage tank unit probeZone 1 mixer valve (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 safety thermostat (CMI-1)Zone 1 temperature probe (CMI-1)Zone 2 mixer valve (CMI-2)Zone 2 heating circuit pump (CMI-2)

123456789

keyVICTRIX generatorExternal probeThermometer trapFuel on-off valve bulbISPESL approved pressure gauge cockFuel on-off valveISPESL approved thermometerISPESL approved manually reset thermostatISPESL approved manually reset pressure switchExpansion vessel connection

12345678910

Expansion vesselManifold/mixerSludge collecting system filterCommon delivery probeZone managerZone 1 safety thermostat (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 temperature probe (CMI-1)Zone 1 mixer valve (CMI-1)Zone 2 safety thermostat (CMI-2)

11121314151617181920

Zone 2 heating circuit pump (CMI-2)Zone 2 temperature probe (CMI-2)Zone 2 mixer valve (CMI-2)Modulating room thermostatNon return valveZone 3 direct circuit pump (CD)Cascade and zones regulatorStorage tank unit supply pumpStorage tank unitStorage tank unit probe

21222324252627282930

Zone 2 safety thermostat (CMI-2)Zone 2 temperature probe (CMI-2)Common delivery probeZone managerModulating room thermostatExternal main switchExternal probeCascade and zones regulatorVICTRIX generator

101112131415161718

Single generator with high/low temperature zones system and separate storage tank for the domestic hot water production

SINGLE INSTALLATION

Hydraulic scheme

Electrical schemeSingle generator with high/low temperature zones system and separate storage tank for the domestic hot water production 21

Page 22: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

253

350

140

200

600 570

2995

2120

400

470

635

ø160

982

330

510 800800

3~

1~

G 1 ”1/2

G 1 ”1/2 G 1 ”1/2 G 1 ”1/2

G 2

1 / 2

G 2

1 / 2

VICTRIX 115 main dimensions and connections

VICTRIX 90 main dimensions and connections

ø160

G 1 1/2"

G 1 1/2"

G 1 1/2" G 1 1/2"G

1 1/

2"

299540

0

470

635

ø200

253600

200

982

2170

570

140

35033

0

510 800800

3~̀1~

G 1

1/2"

CASCADE INSTALLATION

22

Page 23: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

3120 460

232

220

435

2020

905

200

330

365

650 800

ø125

3%

600

600

570

800

G 1 ”1/2 G 1 ”

G 1

”1/2 1 / 2

G 2

1 / 2

VICTRIX 50 main dimensions and connections

VICTRIX 75 main dimensions and connections

G 1 1/2" G 1 1/2"G

1 1

/2"

G 1

1/2

"G 1 1/2"

G 1 1/2"

600 570ø

160

400

2040

2995

232

220

330

905

200

510 800800

460

435

598

3~̀1~

CASCADE INSTALLATION

23

Page 24: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

ZONE 1(CMI1)

ZONE 2(CMI2)

ZONE 3(CD)

CondensateDrain

Gas supply

System filling

1

1 1 1

2

4

2

3

1 1

5

22

32

2

3

4

22

67

10

11

12

13

8 9

3

22

67

10

11

12

13

17 17

23 3

18

19

2021

22 26

28

29 3

30

31

25 2724

14

15

16

8 9

32

2

3

ZONE 3 STORAGE TANK UNIT ZONE 1 ZONE 2

Com

mon

Ope

nC

lose

Com

mon

Ope

nC

lose

230 Vac50Hz

Address 0 Address 1 Address 2 Address 3 Address 4 Address 5

1 2

3

4

6

5

7

8

9

1011

12

A B A B A B

13 13

14

M M

15

16

18 18 18 18 18 18

17

keyZone 3 direct circuit pump (CD)Storage tank unit supply pumpStorage tank unit probeZone 1 mixer valve (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 safety thermostat (CMI-1)Zone 1 temperature probe (CMI-1)Zone 2 mixer valve (CMI-2)Zone 2 heating circuit pump (CMI-2)Zone 2 safety thermostat (CMI-2)Zone 2 temperature probe (CMI-2)Common delivery probeZone managerModulating room thermostatExternal main switchCascade and zones regulatorExternal probeVICTRIX generator

123456789101112131415161718

keyVICTRIX generatorSystem shut off knobNon return valveFuel on-off valveExternal probeThermometer trap

123456

ISPESL approved thermometerISPESL approved manually reset pressure switchISPESL approved manually reset thermostatISPESL approved pressure gauge cockFuel on-off valve bulbExpansion vessel connection

789101112

Expansion vesselCommon delivery probeSludge collecting system filterManifold/mixerZone managerModulating room thermostatZone 1 safety thermostat (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 temperature probe (CMI-1)Zone 1 mixer valve (CMI-1)Zone 2 safety thermostat (CMI-2)Zone 2 heating circuit pump (CMI-2)Zone 2 temperature probe (CMI-2)Zone 2 mixer valve (CMI-2)Zone 3 direct circuit pump (CD)Cascade and zones regulatorStorage tank unit supply pumpStorage tank unitStorage tank unit probe

13141516171819202122232425262728293031

Double battery of generators with high/low temperature zones system and separate storage tank for the domestic hot water productionHydraulic scheme

Electrical schemeDouble battery of generators with high/low temperature zones system and separate storage tank for the domestic hot water production

CASCADE INSTALLATION

24

Page 25: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

Condensatedrain

Gas supply

System filling

ZONE 1(CMI1)

ZONE 2(CMI2)

ZONE 3(CD)

ZONE 1(CMI1)

ZONE 2(CMI2)

ZONE 3(CD)

1

22

32

2

32

2

5

67 8 9

1032

143

11

12

1615

32

17

23

2122

20

18 18

24

25

27

26 28

29

3

3

30

31

19

17-1

23-1

24-1

25-126-1 28-1

29-1 31-127-1

21-122-1

20-1

18-1 18-1 19-1

3

3

30

13

1 1

keyVICTRIX generatorSystem shut off knobNon return valveFuel on-off valveExternal probeThermometer trapISPESL approved thermometerISPESL approved manually reset pressure switchISPESL approved manually reset thermostatISPESL approved pressure gauge cockFuel on-off valve bulbExpansion vessel connectionExpansion vesselCommon delivery probeSludge collecting system filterManifold/mixerCascade and zones regulator

1234567891011121314151617

Zone managerModulating room thermostatZone 1 safety thermostat (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 temperature probe (CMI-1)Zone 1 mixer valve (CMI-1)Zone 2 safety thermostat (CMI-2)Zone 2 heating circuit pump (CMI-2)Zone 2 temperature probe (CMI-2)Zone 2 mixer valve (CMI-2)

18192021222324252627

Zone 3 direct circuit pump (CD)Storage tank unit supply pumpStorage tank unitStorage tank unit probebalancing valve

2829303132

ZONE 3 STORAGE TANKUNIT

ZONE 1

Com

mon

Ope

nC

lose

Com

mon

Ope

nC

lose

ZONE 2 ZONE 3-1 ZONE 1-1 ZONE 2-1STORAGE TANKUNIT

Com

mon

Ope

nC

lose

Com

mon

Ope

nC

lose

230Vac50Hz

Address 0 Address 1 Address 2

1 2 3

4

5

7

8

9

A B A B A B A B A B

A B

13

12

13

14

1-1

2-1

3-1

4-1

6-1 10-1

7-1 11-1

13-1 13-1

14-1

8-1

9-15-1

10

11

6

M M M M

16-1

15

16

17

18 18 18Zone 2 temperatureprobe (CMI-2)Common delivery probeZone managerModulating room thermostatExternal main switchCascade and zones regulatorExternal probeVICTRIX generator

11

12131415161718

Battery of generators with 6 high/low temperature zones systems and 2 separate storage tanks for the domestic hot water productionHydraulic scheme

Electrical schemeBattery of generators with 6 high/low temperature zones systems and 2 separate storage tanks for the domestic hot water production

keyZone 3 direct circuit pump (CD)Storage tank unit supply pumpStorage tank unit probeZone 1 mixer valve (CMI-1)Zone 1 heating circuit pump (CMI-1)Zone 1 safety thermostat (CMI-1)Zone 1 temperature probe (CMI-1)Zone 2 mixer valve (CMI-2)Zone 2 heating circuit pump (CMI-2)Zone 2 safety thermostat (CMI-2)

12345678910

CASCADE INSTALLATION

25

Page 26: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

SINGLE INSTALLATIONAll light commercial VICTRIX models are standard provided in B23 configuration (open chamber, fan assisted) but they can work also as sealed chamber fan assisted (C type) using the special kits supplied by Immergas. To correctly install the boiler, it is necessary to use the original

Immergas “Green Series” flue systems; these components and accessories are specially designed to guarantee higher resistance to corrosion and fast and easy installation, thanks also to the push-fit assembly and special gasket seals.

Open chamber fan assistedinstallation (B23 type)

Horizontal kit Ø 80 (to discharge in the chimney) 3.015254

Terminal horizontal outlet kit Ø 80 3.015255(to discharge horizontally)

Terminal vertical outlet kit Ø 80 3.015256

4 extension pipes Ø 80 kit 0,5 m long 3.014642

4 extension pipes Ø 80 kit 1 m long 3.012088

1 extension pipe Ø 80 2 m long 3.016837

4 x 90° bends Ø 80 kit 3.012091

45° bend Ø 80 kit 3.012092

Description Code

fLUE SySTEMS

26

Page 27: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

fLUE SySTEMS

Horizontal concentric kit Ø 80/125 3.015242

Vertical concentric kit Ø 80/125 3.015243

Extension pipe kit Ø 80/125 2 m long 3.015246

Extension pipe kit Ø 80/125 1 m long 3.018667

87° bend kit Ø 80/125 3.015247

2 x 45° bend kit Ø 80/125 3.015248

Flashing kit Ø 80/125 for flat roof 3.015249

Sealed chamber fan assistedinstallation (C type) Description Code

27

Page 28: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

CASCADE INSTALLATIONIn case of cascade systems in B23 configuration (open chamber, fan assisted), it is necessary to use a special flue manifold with a non-return device (flue locks) supplied by

Immergas, so that the combustion products of one working boiler do not interfere with the combustion circuit of the not working boilers.

Exhaust manifold kit with flue locks Ø 160 for 2 boilers 3.020476in cascade (including a condense draining siphon)

Exhaust manifold kit with flue lock Ø 200 with adapter 3.020954for the additional boiler

vICTRIx 115 Description Code

vICTRx 90/75 Description Code

Exhaust manifold kit with flue locks Ø 160 for 2 boilers 3.020476in cascade (including a condense draining siphon)

Exhaust manifold kit with flue lock Ø 160 3.020701for the additional boiler

fLUE SySTEMS

28

Page 29: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

fLUE SySTEMS

Exhaust manifold kit with flue locks Ø 125 for 2 boilers 3.015240in cascade (including a condense draining siphon)

Exhaust manifold kit with flue lock Ø 125 3.015241for the additional boiler

Extension pipe Ø 125 kit 0,5 m long for flue manifold 3.016370

Extension pipe Ø 125 kit 1 m long for flue manifold 3.016371

Extension pipe Ø 125 kit 2 m long for flue manifold 3.015250

90° bend kit Ø 125 mm for flue manifold 3.016179

2 x 45° bend kit Ø 125 mm for flue manifold 3.016180

Adapter Ø 125/160 for flue manifold 3.016215

vICTRIx 50 Description Code

29

Page 30: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

Cascade and zones regulator 3.015244

Zone manager 3.015264

Flow probe 3.015267

Storage tank sensor (for managing the storage 3.015268tank as a zone)

Electrical connection kit for cascade and zones regulator 3.015269(to be installed to an external electric panel)

External sensor 3.015266

Wall box for cascade and zones regulator 3.015265

Modulating room thermostat 3.015245

Description Code

CLIMATIC REGULATIONThe climatic accessory range, exclusively designed for light commercial VICTRIX boilers, allows the optimization of the heating system climatic regulation, both in case of single installation and cascade systems.The modularity of Immergas regulation system allows to

customize the installation according to the specific needs. Moreover, the cascade and zones regulator offers the possibility to control a solar system for domestic hot water production.

MAIN OPTIONS

Anti-freeze protection kit -15 °C 3.015361

30

Page 31: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

MAIN OPTIONS

Safety kit for single boiler (it includes thermometer, 3.015222thermometer holder, lock, thermostat with manual reset,connection tap for pressure gauge, manual resetpressostat, gas intercepting valve trap, expansion vesselconnection)

Three-way valve kit connection to a separate storage tank 3.015223(it includes the storage tank probe)

Hydraulic manifold for single boiler (it includes a mud-filter 3.015224on the return pipe)

Hydraulic manifold for 2 boilers in cascade (including 3.015225the intercepting valve and the non-return valve for eachappliance)

Safety kit for boilers in cascade (it includes thermometer, 3.015227thermometer holder, lock thermostat with manual reset,connection tap for pressure gauge, manual resetpressostat, gas intercepting valve trop, expansionvessel connection)

Hydraulic manifold for additional boiler in cascade 3.015226(including the intercepting valve and the non-return valve)

Description Code

HyDRAULIC SySTEMThe hydraulic kits, especially dedicated to light commercial VICTRIX models, are designed to simplify the installation operations and to optimize the boiler performances.

The hydraulic manifolds for the cascade installation are provided with intercepting valves allowing the boiler maintenance without having to stop the whole system.

Code

31

Page 32: LIGHT COMMERCIAL BOILERSofaclimatizacao.com/wp-content/uploads/2013/01/Victrix...3.020425 3.020425GPL 90,0 4 stars • • IPX5D -5 C Main options Code External sensor 3.015266 Three-way

IMMERGAS SPA - ITALYCERTIFIED COMPANYUNI EN ISO 9001:2000

Design, manufacture and post-sale assistance of gas boilers, gas water heaters and related accessories

Immergas S.p.A. - 42041 Brescello (RE) ItalyT. +39.0522.689011 - F. +39.0522.689178www.immergas.com

During the life of a boiler, performance is influenced by external factors, e.g. water hardness, atmospheric agents, system limiting, etc.The published data refers to new products correctly installed and used, in accordance with local regulations. N.B. we recommend regular periodic maintenance of the appliance. Im

mer

gas

rese

rves

the

rig

ht t

o m

ake

such

cha

nges

to

its p

rod

ucts

as

are

dee

med

nec

essa

ry fo

r th

eir

evol

utio

n, w

ithou

t p

rior

notic

e. C

od. C

E.0

419

- re

v. 0

00 (v

er. 1

214)

- 1

0/09