Legend - SSE Renewables
Transcript of Legend - SSE Renewables
#*
#*
#0
#0
#0
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!( !(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
T69 T72
T1
T2
T70
T4
T6
T8T56
T61
T9T10
T11T50
T52T57
T13T15
T17
T45 T46
T49T47
T18T19
T20T29T41 T42
T22 T24
T26
T30
T35
T39 T43
T28T33T36
11
12
13
8
3
1
2
4
5
7
9
10
14
15
16
19
0 0.5 1Km ±
Proposed Varied DevelopmentFigure 2.1
Strathy South Wind FarmEIAR 2020
© Crown copyright and database rights 2020 Ordnance Survey 0100031673
1:30,000Scale @ A3
LegendSite Boundary
!( TurbineWater Crossing Points!( Water Crossing!( Water Crossing - New#0 Water Abstraction Location
LiDAR Optioins#* LiDAR A#* LiDAR B
LiDAR TrackAccess Track
CutFloatingUpgrade
Potential AccessDetails
Preferred Access RouteAlternative Access RouteCommon Access Route
Indicative Cable RouteDetails
Preferred Indicative Cable Routethrough Strathy NorthAlternative Indicative Cable Routethrough Strathy NorthCommon Indicative Cable Routethrough Strathy NorthExisting Yellow Bog Track,Surfacing to be Upgraded andMinor Localised WideningSubstation Temporary LaydownAreaConstruction CompoundSite BoundarySubstationHardstandBatching PlantAmended Laydown AreaBorrow Pit
#*
#*
#0
#0
#0
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
$+$+
$+
$+
$+
$+
$+
$+
$+
$+
$+
$+
$+
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
T69T72
T1
T2
T70
T4
T6
T8T56
T9T10
T11T50
T52T57
T13T15
T17
T45 T46
T49
T47
T18T20T29
T41 T42
T22 T24
T26
T30
T35
T39 T43
T28T33
T36
11
12
13
8
3
1
4
5
7
9
10
14
15
16
19
0 0.5 1Km ±
Layout ConstraintsFigure 2.2
Strathy South Wind FarmEIAR 2020
© Crown copyright and database rights 2020 Ordnance Survey 0100031673
1:45,000Scale @ A3
LegendSite Boundary
!( Turbine
$+ Non-designated heritage assetsWater Crossing Points!( Water Crossing
!( Water Crossing - New#0 Water Abstraction Location
LiDAR Optioins
#* LiDAR A (278609, 948990)
#* LiDAR B (278186, 952895)LiDAR TrackAccess TrackYellow Bog
Potential AccessPreferred Access RouteAlternative Access RouteCommon Access Route
Indicative Cable RoutePreferred Indicative Cable Route through Strathy NorthAlternative Indicative Cable Route through Strathy NorthCommon Indicative Cable Route through Strathy North405m648m70m Water Buffer based on 50kGWDTE with 100m BufferUnForested AreasAvoid area SNHSurface WaterSubstation Temporary LaydownConstruction CompoundSubstationHardstandBatching PlantAmended Laydown AreaBorrow PitSAC/SPA
Peat Depth00 - 0.50.5 - 11 - 1.51.5 - 22 - 2.52.5 - 3.5> 3.5
Tower
Rotor hub
Blade
Indi
cativ
e hu
b he
ight
119
m
Max
tip
heig
ht 2
00
Max rotor
diameter Ø162
Figure 2.3Typical Turbine Elevation
Strathy South Wind FarmEIAR 2020
Scale 1:1000 @ A3
0 20 4010 30m
Notes
1. All dimensions are in metres
SECTION THROUGH TURBINE FOUNDATION
27000
6000Ø
CONCRETE FOUNDATION
℄
100
10500 10500 BALLAST FILLMIN UNIT WEIGHTOF 18kN/m³
6N STRUCTURALUPFILL
FORMATION
SUB-FORMATION
CONCRETEBLINDING
BACKFILL
OGL
BACKFILL
Notes
1. All dimensions are in millimetres.
2. A piled base option may be useddepending upon ground conditions.
3. Dimensions shown are indicative andmay be subject to change at detaileddesign stage.
Figure 2.4Typical Turbine Foundation
Strathy South Wind FarmEIAR 2020
Scale 1:200 @ A3
0 2 4 6m
HARDSTANDING AREA(PERMANENT)
55m
39m
4m
33m
12m
12m
3m
25m
25m
5m
20m
49m 4m
18m
APPROXIMATE HARDSTANDING (+INDICATIVE EARTHWORKS ENBANKMENT) AREAS:· TEMPORARY ≈ 800m²· PERMANENT ≈ 2520m²
INDICATIVE TURBINE EARTHWORKS (TEMPORARY)INDICATIVE TURBINE EARTHWORKSINDICATIVE TURBINE FOUNDATION
ACCESS ROAD
HARDSTANDING AREA(TEMPORARY)
HARDSTANDING AREA(TEMPORARY)
Notes
1. All dimensions are in metres (m) unlessstated otherwise.
2. Layout is indicative only and will besubject to change depending uponselected wind turbine generatorsupplier.
Scale 1:1000 @ A3
0 20 4010 30m
Figure 2.5Proposed Hardstanding Area And
Crane Platform
Strathy South Wind FarmEIAR 2020
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
T69 T72
T1
T2
T70
T4
T6
T8T56
T61
T9T10
T11T50
T52T57
T13T15
T17
T45 T46
T49T47
T18T19
T20T29T41 T42
T22 T24
T26
T30
T35
T39 T43
T28T33T36
0 1 2Km ±
Access RouteFigure 2.6
Strathy South Wind FarmEIAR 2020
KeySite Boundary
!( TurbineAccess Track
CutFloatingUpgradeExisting Yellow Bog Track, Surfacing tobe Upgraded and Minor LocalisedWideningStrathy Northern Access Route
Potential AccessPreferred Access RouteAlternative Access RouteCommon Access Route
© Crown copyright and database rights 2020 Ordnance Survey 0100031673
1:60,000Scale @ A3
#*
#*
#0
#0
#0
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(
!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(
!(!(
!(!(
!(
!(
!(
!(
!(
!(
!(
!(
T69 T72
T1
T2
T70
T4
T6
T8T56
T61
T9T10
T11T50
T52T57
T13T15
T17
T45 T46
T49T47
T18T19
T20T29T41 T42
T22 T24
T26
T30
T35
T39 T43
T28T33
T36
11
12
13
8
2
4
5
7
9
10
14
15
16
19
0 0.5 1km ±
On-Site Access Track (cut and floating and upgrades)
Figure 2.7
Strathy South Wind FarmEIAR 2020
© Crown copyright and database rights 2020 Ordnance Survey 0100031673
1:25,000Scale @ A3
LegendSite Boundary
!( TurbineWater Crossing Points!( Water Crossing!( Water Crossing - New#0 Water Abstraction
LiDAR Optioins#* LiDAR A#* LiDAR B
Track to LiDARCutUpgrade
Access TrackCutFloatingUpgrade
Potential AccessDetails
Preferred AccessAlternative AccessCommon AccessExisting Yellow Bog Track,Surfacing to be Upgraded andMinor Localised WideningSubstation Temporary LaydownAreaSubstationHardstand
25000
PLAN OF TYPICAL PASSING PLACES ON ACCESS TRACKSScale: 1:250
Proposed Passing Place
Access Road
3000
15000
Running width 4500 to 6000
600
TYPICAL FLOATING TRACK SECTIONScale: 1:50
Crossfall
Min 150mm Wearing Course
Crushed rock
Top surface of slopesfinished with
reinstated material
Upper layerof geotextile
Lower layer of geotextileanchored to existingground profile
Cable trenches at side of road omitted forclarity. Cables may be installed in verges
21
500500
500 500Running width 4500 to 6000
Crossfall
Dimensions of drainageditch will vary dependingon local hydrologicalconditions
All slopes reinstatedwith previous excavatedmaterial
Suitableformation level
Existingground level
Topsoil and subsoil excavatedand constructed on suitable
formation horizonMin 150mm Wearing Course
Crushed rockcompacted in
layers
Reinstated material
TYPICAL CUT TRACK SECTIONScale: 1:50
1.51
Notes
1. All dimensions are in millimetres (mm)unless stated otherwise.
Scale 1:250 @ A3
0 5 10m
Scale 1:50 @ A3
0 1 2m
Scale 1:50 @ A3
0 1 2m
Figure 2.8Typical Access Track Cross Section
Strathy South Wind FarmEIAR 2020
PARKING
150m
52.5m
53m PALISADE FENCE
AROUND SSENCOMPOUND
SSERSUBSTATION
DVAR
AUXTRANSFORMERS
23.5m
100m
200m
TEMPORARY OVERFLOWCAR PARK AND
LAYDOWN AREA
SSEN 1
17.52m 28m46
m46
m28.48m
SSEN 1
6mGATE
6mPOST & WIRE FENCEAROUND SSER
COMPOUND
ACCE
SS R
OAD
PALISADE FENCEAROUND DVAR
22m 22m
Notes
1. All dimensions are in metres (m) unlessstated otherwise.
2. Layout and dimensions are indicativeand are subject to change after detaileddesign.
3. Given site location, it is possible that"outdoor" equipment will require to beinstalled within buildings. Thesebuildings are shown as a dashed line.
4. Additional transmission busbar worksmay be required to link the twotransformers. This is dependent on thespecific connection voltage and designprovided by SHETL.
Scale 1:1000 @ A3
0 20 4010 30m
Figure 2.9Substation Layout - Plan
Strathy South Wind FarmEIAR 2020
1. FRONT ELEVATION
PALISADEFENCE
OPSBUILDING
SUBSTATIONBUILDING 2
DVARAREA 11.51
4.80FGL0.00
6.872.75
POST & WIREFENCE
6mGATE
2. RIGHT ELEVATION
SUBSTATIONBUILDING 1
SUBSTATIONBUILDING 211.51
FGL0.00
PALISADEFENCE
TEMPORARY OVERFLOW CAR PARKAND LAYDOWN AREA
100m
3. BACK ELEVATION
FGL0.00
PALISADEFENCE
OPSBUILDING
SUBSTATIONBUILDING 1 DVAR
AREA11.51
4.80 6.872.75
POST & WIREFENCE
6mGATE
4. LEFT ELEVATION
11.51
FGL0.00
SUBSTATIONBUILDING 2
OPSBUILDING
DVARAREA
SUBSTATIONBUILDING 1
POST & WIREFENCE
TEMPORARY OVERFLOW CAR PARKAND LAYDOWN AREA
100m
KEY PLAN
4 2
1
3
1
2
Scale 1:1000 @ A3
0 20 4010 30m
Notes
1. All dimensions are in metres (m) unlessstated otherwise.
2. Layout and dimensions are indicativeand are subject to change after detaileddesign.
3. Given site location, it is possible that"outdoor" equipment will require to beinstalled within buildings. Thesebuildings are shown as a dashed line.
4. Additional transmission busbar worksmay be required to link the twotransformers. This is dependent on thespecific connection voltage and designprovided by SHETL.
Figure 2.10Indicative SubstationLayout - Elevations
Strathy South Wind FarmEIAR 2020