LED modules LED linear / area Module LLE 55x280/566mm 2000 ... · ACL CLIP 4.3mm PUSH-FIX Long...

13
www.tridonic.com 1 Subject to change without notice. Information provided without guarantee. Data sheet 07/20-LED509-4 LED modules LED linear / area Product description • Ideal for linear and panel lights • Perfectly uniform light, even if several LED modules are used together in a line • Push terminals for quick and simple wiring of LED module to LED module • Long life-time: 72,000 hours • 5-year guarantee Optical properties • Colour temperature 3,000 K, 4,000 K and 5,000 K • Typ. luminous flux 2,000 and 4,000 lm • Efficacy of the module up to 207 lm/W • High colour rendering index CRI > 80 • High colour consistency (MacAdam 3) 1 • Small luminous flux tolerances Mechanical properties • Module dimension 55 x 280 mm and 55 x 566 mm • Simple installation (e.g. screws) System solution • LED system solution with outstanding system efficiency up to 190 lm/W, consisting of linear LED modules and dimmable LED Driver LCA 50W 350-1050mA one4all lp PRE È Standards, page 7 Colour temperatures and tolerances, page 11 Module LLE 55x280/566mm 2000/4000lm LV ADV5 Modules LLE advanced LLE 55x280mm 2000lm LV ADV5 LLE 55x566mm 4000lm LV ADV5

Transcript of LED modules LED linear / area Module LLE 55x280/566mm 2000 ... · ACL CLIP 4.3mm PUSH-FIX Long...

www.tridonic.com 1Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

Product description

• Ideal for linear and panel lights

• Perfectly uniform light, even if several LED modules are used

together in a line

• Push terminals for quick and simple wiring of LED module to

LED module

• Long life-time: 72,000 hours

• 5-year guarantee

Optical properties

• Colour temperature 3,000 K, 4,000 K and 5,000 K

• Typ. luminous flux 2,000 and 4,000 lm

• Efficacy of the module up to 207 lm/W

• High colour rendering index CRI > 80

• High colour consistency (MacAdam 3)1

• Small luminous flux tolerances

Mechanical properties

• Module dimension 55 x 280 mm and 55 x 566 mm

• Simple installation (e.g. screws)

System solution

• LED system solution with outstanding system efficiency up to

190 lm/W, consisting of linear LED modules and dimmable

LED Driver LCA 50W 350-1050mA one4all lp PRE

ÈStandards, page 7

Colour temperatures and tolerances, page 11

Module LLE 55x280/566mm 2000/4000lm LV ADV5

Modules LLE advanced

LLE 55x280mm 2000lm LV ADV5

LLE 55x566mm 4000lm LV ADV5

www.tridonic.com 2Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

Technical dataBeam characteristic 120°

Ambient temperature range -40 ... +65 °C

tp rated 50 °C

tc 95 °C

Irated for 2000lm 375 mA

Irated for 4000lm 750 mA

Imax for 2000lm 540 mA

Imax for 4000lm 1,080 mA

Max. permissible LF current ripple for 2000lm 595 mA

Max. permissible LF current ripple for 4000lm 1,190 mA

Max. permissible peak current for 2000lm 900 mA / max. 8 ms

Max. permissible peak current for 4000lm 1,800 mA / max. 8 ms

Max. working voltage for insulation2 450 V

Insulation test voltage 1.9 kV

CTI of the printed circuit board ≥ 600

ESD classification severity level 4

Risk group (IEC 62471) for 2000lm at ≤ 470 mA RG0

Risk group (IEC 62471) for 2000lm at Imax RG1

Risk group (IEC 62471) for 4000lm at ≤ 940 mA RG0

Risk group (IEC 62471) for 4000lm at Imax RG1

Classification acc. to IEC 62031 Built-in

Type of protection IP00

Module LLE 55x280/566mm 2000lm LV ADV5

Modules LLE advanced

7,75125151

49 182280

1,65

max

. 5,5

27,5

7,5

47,555

1,5tc

ø4,8(4x)

LLE 55x280mm 2000lm LV ADV5

566

1,65

max

. 5,5

55 47,5

27,5 7,5

7,75

1,5

0 49 125 151 231 335 411 437 517

tcø4,8(8x)

LLE 55x566mm 4000lm LV ADV5

Ordering data

TypeArticle number

Colour temperature

Packaging carton

Weight per pc.

LLE 55x280mm 2000lm 830 LV ADV5 89603417 3,000 K 128 pc(s). 0.049 kg

LLE 55x280mm 2000lm 840 LV ADV5 89603419 4,000 K 128 pc(s). 0.049 kg

LLE 55x280mm 2000lm 850 LV ADV5 89603420 5,000 K 128 pc(s). 0.049 kg

LLE 55x566mm 4000lm 840 LV ADV5 89603424 4,000 K 96 pc(s). 0.099 kg

LLE 55x566mm 4000lm 850 LV ADV5 89603425 5,000 K 96 pc(s). 0.099 kg

www.tridonic.com 3Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

Specific technical dataType3 Photo-

metric code

Typ.luminous flux

at tp = 25 °C4

Typ.luminous flux

at tp = 50 °C4

Typ. forward current

Min. forward voltage

at tp = 50 °C

Max. forward voltage

at tp = 25 °C

Typ. power consumption

at tp = 50 °C4

Efficacy of the module at tp = 25 °C

Efficacy of the module at tp = 50 °C

Efficacy of the system at tp = 50 °C

Colour rendering index CRI

Operating mode HE at 200 mA per feet (280 mm module length)LLE 55x280mm 2000lm 830 LV ADV5 830 / 359 1,170 lm 1,140 lm 200 mA 28.1 V 31.2 V 5.9 W 195 lm/W 192 lm/W 177 lm/W > 80

LLE 55x280mm 2000lm 840 LV ADV5 840 / 359 1,240 lm 1,210 lm 200 mA 28.1 V 31.2 V 5.9 W 206 lm/W 202 lm/W 186 lm/W > 80

LLE 55x280mm 2000lm 850 LV ADV5 850 / 359 1,270 lm 1,230 lm 200 mA 28.1 V 31.2 V 5.9 W 211 lm/W 207 lm/W 190 lm/W > 80

LLE 55x566mm 4000lm 840 LV ADV5 840 / 359 2,470 lm 2,400 lm 400 mA 28.1 V 31.2 V 11.9 W 206 lm/W 202 lm/W 186 lm/W > 80

LLE 55x566mm 4000lm 850 LV ADV5 850 / 359 2,530 lm 2,470 lm 400 mA 28.1 V 31.2 V 11.9 W 211 lm/W 207 lm/W 190 lm/W > 80

Operating mode NM at 375 mA per feet (280 mm module length)LLE 55x280mm 2000lm 830 LV ADV5 830 / 359 2,090 lm 2,040 lm 375 mA 29.0 V 32.2 V 11.5 W 180 lm/W 177 lm/W 163 lm/W > 80

LLE 55x280mm 2000lm 840 LV ADV5 840 / 359 2,200 lm 2,140 lm 375 mA 29.0 V 32.2 V 11.5 W 190 lm/W 186 lm/W 171 lm/W > 80

LLE 55x280mm 2000lm 850 LV ADV5 850 / 359 2,260 lm 2,190 lm 375 mA 29.0 V 32.2 V 11.5 W 195 lm/W 191 lm/W 176 lm/W > 80

LLE 55x566mm 4000lm 840 LV ADV5 840 / 359 4,400 lm 4,290 lm 750 mA 29.0 V 32.2 V 23.0 W 190 lm/W 186 lm/W 171 lm/W > 80

LLE 55x566mm 4000lm 850 LV ADV5 850 / 359 4,500 lm 4,390 lm 750 mA 29.0 V 32.2 V 23.0 W 195 lm/W 191 lm/W 176 lm/W > 80

Operating mode HO at 500 mA per feet (280 mm module length)LLE 55x280mm 2000lm 830 LV ADV5 830 / 359 2,730 lm 2,660 lm 500 mA 29.6 V 32.7 V 15.6 W 173 lm/W 170 lm/W 156 lm/W > 80

LLE 55x280mm 2000lm 840 LV ADV5 840 / 359 2,860 lm 2,790 lm 500 mA 29.6 V 32.7 V 15.6 W 182 lm/W 178 lm/W 164 lm/W > 80

LLE 55x280mm 2000lm 850 LV ADV5 850 / 359 2,940 lm 2,850 lm 500 mA 29.6 V 32.7 V 15.6 W 186 lm/W 182 lm/W 167 lm/W > 80

LLE 55x566mm 4000lm 840 LV ADV5 840 / 359 5,730 lm 5,570 lm 1.000 mA 29.6 V 32.7 V 31.3 W 182 lm/W 178 lm/W 164 lm/W > 80

LLE 55x566mm 4000lm 850 LV ADV5 850 / 359 5,870 lm 5,710 lm 1.000 mA 29.6 V 32.7 V 31.3 W 186 lm/W 182 lm/W 167 lm/W > 80

1 Integral measurement over the complete module.

2 If mounted with M4 screws and plastic washers.

3 HE ... high efficiency, NM ... nominal mode, HO ... high output.

4 Tolerance range for optical and electrical data: ±10 %.

www.tridonic.com 4Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

ACL LENS 55x280mm

ACC

ES-

SOR

IES

ACL LENS 55x280mm 60°

ACL LENS 55x280mm DA25°

ACL SHADE 55x280mm UGR

Product description

• ACL LENS for LLE 55x280mm

• Available with different beam characteristics

• For SELV applications only

• Easy mounting with M4 screws

• ACL SHADE to reduce UGR

• ACL LENS made of PMMA, ACL SHADE made of ABS

• Max. permissible temperature 80 °C

• Photometric data available on website

ACL LENS 55x280mm

ACC

ES-

SOR

IES

618,45

286

182

ACL LENS (28002206, 28002207, 28002208)

6111,4

286

182

ACL LENS (28002209, 28002210)

65,58

12,95

2,3

290,58

4,887,46

ACL SHADE (28002211)

Ordering data

TypeArticle number

Beam characteristic EfficiencyPackaging carton

Weight per pc.

ACL LENS 55x280mm 60° 28002206 60° 91 % 72 pc(s). 0.088 kg

ACL LENS 55x280mm 90° 28002207 90° 90 % 72 pc(s). 0.092 kg

ACL LENS 55x280mm 90x45° 28002208 90x45° 90 % 72 pc(s). 0.091 kg

ACL LENS 55x280mm DA25° 28002209 double asymmetric 25° 94 % 60 pc(s). 0.072 kg

ACL LENS 55x280mm A20° 28002210 asymmetric 20° 93 % 60 pc(s). 0.058 kg

ACL SHADE 55x280mm UGR 28002211 UGR improving – 60 pc(s). 0.027 kg

www.tridonic.com 5Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

ACL LENS 55x280mm

ACC

ES-

SOR

IES

618,45

286

182

ACL LENS (28002206, 28002207, 28002208)

6111,4

286

182

ACL LENS (28002209, 28002210)

65,58

12,95

2,3

290,58

4,887,46

ACL SHADE (28002211)

Ordering data

TypeArticle number

Beam characteristic EfficiencyPackaging carton

Weight per pc.

ACL LENS 55x280mm 60° 28002206 60° 91 % 72 pc(s). 0.088 kg

ACL LENS 55x280mm 90° 28002207 90° 90 % 72 pc(s). 0.092 kg

ACL LENS 55x280mm 90x45° 28002208 90x45° 90 % 72 pc(s). 0.091 kg

ACL LENS 55x280mm DA25° 28002209 double asymmetric 25° 94 % 60 pc(s). 0.072 kg

ACL LENS 55x280mm A20° 28002210 asymmetric 20° 93 % 60 pc(s). 0.058 kg

ACL SHADE 55x280mm UGR 28002211 UGR improving – 60 pc(s). 0.027 kg

www.tridonic.com 6Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

CLIP 4.3mm

ACC

ES-

SOR

IES

ACL CLIP 4.3mm PUSH-FIX ACL CLIP 4.3mm PUSH-FIX Long

ø5.3ø3.6

2.2±

0.05

1.2ø9

7.4

ø5.3ø3.6

2.9±

0.05

1.2ø9

8.1

ACL CLIP 4.3mm PUSH-FIX ACL CLIP 4.3mm PUSH-FIX Long

Ordering dataType Article number Colour Packaging bag1 Weight per pc.

ACL CLIP 4.3mm PUSH-FIX 28001036 White 500 pc(s). 0.001 kg

ACL CLIP 4.3mm PUSH-FIX Long 28002314 Transparent 500 pc(s). 0.001 kg

Product description

• Clip for fixation of LED modules with 4.3 mm holes

• Fast snap on mounting (sheet thickness 0.5 – 1.0 mm for

PUSH-FIX and 1 – 2 mm for PUSH-FIX Long)

• For drilling hole 4 mm

• Clip made of Polycarbonat

1 Minimum sales quantity 500 pcs.

www.tridonic.com 7Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

2. Thermal details

2.1 tc point, ambient temperature and life-time

The temperature at tp reference point is crucial for the light output and life-time of a LED product.

For LLE a tp temperature of 50 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time.

Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application.

The tc and tp temperature of LED modules from Tridonic are measured at the same reference point.

1. Standards

IEC 62031IEC 62471IEC 61000-4-2IEC 62778IEC 61547

2.2 Storage and humidityStorage temperature -40 ... +85 °C

Operation only in non condensing environment.Humidity during processing of the module should be between 30 to 70 %.

1.2 Energy classification

1st digit 2nd + 3rd digit 4th digit 5th digit 6th digit

Code CRIColour

temperature in

Kelvin x 100

MacAdam

initial

MacAdam

after 25%

of the

life-time

(max.6000h)

Luminous flux after 25%

of the life-time (max.6000h)

Code Luminous flux

7 70 – 79 7 ≥ 70 %

8 80 – 89 8 ≥ 80 %

9 ≥90 9 ≥ 90 %

1.1 Photometric code

Key for photometric code, e. g. 830 / 349

Type Energy classification

LLE 55mm LV ADV5 A++

2.3 Heat sink values

NotesThe actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. Depending on the heat sink a heat conducting paste or heat conducting film might be necessary to keep the specified tp temperature.

LLE 55x280mm 2000lm ADV5

ta tp Forward current Rth, hs-a Cooling area

25 °C 50 °C 375 mA 4.26 K/W 156 cm²

25 °C 50 °C 500 mA 2.99 K/W 223 cm²

35 °C 50 °C 375 mA 2.56 K/W 261 cm²

35 °C 50 °C 500 mA 1.79 K/W 372 cm²

40 °C 50 °C 375 mA 1.70 K/W 391 cm²

40 °C 50 °C 500 mA 1.19 K/W 558 cm²

45 °C 50 °C 375 mA 0.85 K/W 784 cm²

45 °C 50 °C 500 mA 0.60 K/W 1,120 cm²

LLE 55x560mm 4000lm ADV5

ta tp Forward current Rth, hs-a Cooling area

25 °C 50 °C 750 mA 2.15 K/W 309 cm²

25 °C 50 °C 1,000 mA 1.51 K/W 441 cm²

35 °C 50 °C 750 mA 1.29 K/W 516 cm²

35 °C 50 °C 1,000 mA 0.91 K/W 735 cm²

40 °C 50 °C 750 mA 0.86 K/W 774 cm²

40 °C 50 °C 1,000 mA 0.60 K/W 1,103 cm²

45 °C 50 °C 750 mA 0.43 K/W 1,551 cm²

45 °C 50 °C 1,000 mA 0.30 K/W 2,211 cm²

www.tridonic.com 8Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

LLE can be operated either from SELV LED Drivers or from LED Drivers with LV output voltage.

LLE are basic insulated up to 450 V (if mounted with M4 screws with head diameter 7 mm in combination with plastic washers) against ground and can be mounted directly on earthed metal parts of the luminaire. If the max. output voltage of the LED Driver (also against earth) is above 450 V, an additional insulation between LED module and heat sink is required (for example by insulated thermal pads) or by a suitable luminaire construction.At voltages > 60 V an additional protection against direct touch (test finger) to the light emitting side of the module has to be guaranteed. This is typically achieved by means of a non removable light distributor over the module.

3.4 Mounting instruction

None of the components of the LLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses.

Max. torque for fixing: 0.5 Nm.

The LED modules are mounted onto a heat sink with min. 2 screws per module or ACL CLIP 4.3mm.

Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections.

Materials which are used in LED applications (e.g. sealings, adhe-sives) must not produce dissolver gas. They must not be condensa-tion curing based, acetate curing based or contain sulfur, chlorine or phthalate.Avoid corrosive atmosphere during usage and storage.

3.2 Wiring

Wiring examples

3.3 Wiring type and cross section

The wiring can be in stranded wires or solid with a cross section of 0.2 to 0.75 mm². For the push-wire connection you have to strip the insulation (8–9 mm).

8 – 9 mm

wire preparation:0.2 – 0.75 mm²

To remove the wires use a suitabel tool (e.g. Microcon release pin) or through twist and pull .

Serial wiring:

Parallel wiring:

out –in + in +out –

–+

LED Driver

LN

+ – + – + – + – + –

out –in + in +out –

–+

LED Driver

LN

+ – + –

out –in + in +out –

Only with modules with the same length possible.

3. Installation / wiring

3.1 Electrical supply/choice of LED Driver

LLE modules from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED Driver which complies with the relevant standards. The use of LED Driver from Tridonic in combination with LLE modules guarantees the necessary protection for safe and reliable operation.

If a LED Driver other than Tridonic is used, it must provide the following protection:• Short-circuit protection• Overload protection• Overtemperature protection

LLE modules must be supplied by a constant current LED Driver.Operation with a constant voltage LED Driver will lead to an irreversible damage of the module.

Wrong polarity can damage the LLE.

With parallel wiring tolerance-related differences in output are possible(thermal stress of the module) and can cause differences in brightness.

If a wire breaks or a complete module fails then the current passing through the other module increases. This may reduce its life considerably.

The max. permissible output current of the LED Driver for parallel wiring is 3 A.

Use only these holes for mounting!

www.tridonic.com 9Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

4.2 Lumen maintenance for LLE 55mm HV ADV5

3.5 EOS/ESD safety guidelines

The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just nor-mal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection

4.1 Life-time, lumen maintenance and failure rate

The light output of an LED Module decreases over the life-time, this is characterized with the L value.L70 means that the LED module will give 70 % of its initial luminous flux. This value is always related to the number of operation hours and therefore defines the life-time of an LED module.

As the L value is a statistical value and the lumen maintenance may vary over the delivered LED modules.The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the initial luminous flux, respectively 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value.

The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux.

4. Life-time

4.3 Switching capability

100,000 cycles

Tridonic test according to IEC 62717 Cl 10.3.330 s on / 30 s off at Imax

Forward

current

tp

tempera-

ture

L90 / F10 L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50

375 mA

40 °C 42,000 h 57,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 41,000 h 55,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 40,000 h 54,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 39,000 h 52,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 38,000 h 50,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 37,000 h 49,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 37,000 h 47,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 36,000 h 46,000 h >72,000 h >72,000 h >72,000 h >72,000 h

80 °C 35,000 h 44,000 h 71,000 h >72,000 h >72,000 h >72,000 h

85 °C 34,000 h 43,000 h 69,000 h >72,000 h >72,000 h >72,000 h

450 mA

40 °C 42,000 h 56,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 41,000 h 55,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 40,000 h 53,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 39,000 h 51,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 38,000 h 50,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 37,000 h 48,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 36,000 h 47,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 35,000 h 45,000 h >72,000 h >72,000 h >72,000 h >72,000 h

80 °C 35,000 h 44,000 h 70,000 h >72,000 h >72,000 h >72,000 h

85 °C 34,000 h 43,000 h 69,000 h >72,000 h >72,000 h >72,000 h

500 mA

40 °C 41,000 h 56,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 40,000 h 54,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 39,000 h 52,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 38,000 h 51,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 38,000 h 49,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 37,000 h 48,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 36,000 h 46,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 35,000 h 45,000 h 71,000 h >72,000 h >72,000 h >72,000 h

80 °C 34,000 h 43,000 h 70,000 h >72,000 h >72,000 h >72,000 h

85 °C 34,000 h 42,000 h 68,000 h >72,000 h >72,000 h >72,000 h

Forward

current

tp

tempera-

ture

L90 / F10 L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50

150 mA

40 °C 43,000 h 59,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 42,000 h 57,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 41,000 h 55,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 40,000 h 54,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 39,000 h 52,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 38,000 h 50,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 38,000 h 49,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 37,000 h 47,000 h >72,000 h >72,000 h >72,000 h >72,000 h

80 °C 36,000 h 46,000 h >72,000 h >72,000 h >72,000 h >72,000 h

85 °C 35,000 h 45,000 h >72,000 h >72,000 h >72,000 h >72,000 h

200 mA

40 °C 43,000 h 58,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 42,000 h 57,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 41,000 h 55,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 40,000 h 53,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 39,000 h 51,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 38,000 h 50,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 37,000 h 48,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 36,000 h 47,000 h >72,000 h >72,000 h >72,000 h >72,000 h

80 °C 36,000 h 45,000 h >72,000 h >72,000 h >72,000 h >72,000 h

85 °C 35,000 h 44,000 h >72,000 h >72,000 h >72,000 h >72,000 h

300 mA

40 °C 42,000 h 58,000 h >72,000 h >72,000 h >72,000 h >72,000 h

45 °C 41,000 h 56,000 h >72,000 h >72,000 h >72,000 h >72,000 h

50 °C 40,000 h 54,000 h >72,000 h >72,000 h >72,000 h >72,000 h

55 °C 40,000 h 52,000 h >72,000 h >72,000 h >72,000 h >72,000 h

60 °C 39,000 h 51,000 h >72,000 h >72,000 h >72,000 h >72,000 h

65 °C 38,000 h 49,000 h >72,000 h >72,000 h >72,000 h >72,000 h

70 °C 37,000 h 48,000 h >72,000 h >72,000 h >72,000 h >72,000 h

75 °C 36,000 h 46,000 h >72,000 h >72,000 h >72,000 h >72,000 h

80 °C 35,000 h 45,000 h >72,000 h >72,000 h >72,000 h >72,000 h

85 °C 34,000 h 44,000 h 70,000 h >72,000 h >72,000 h >72,000 h

www.tridonic.com 10Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

28,0 28,5 29,0 29,5 30,0 30,5 31,0 31,527,50

200

100

32,0

400

300

500

Forward voltage [V]

Forw

ard

curr

ent [

mA

]

5. Electrical values

5.2 Typ. forward voltage vs. forward current

5.1 Declaration of electrical parameters

Irated ... Nominal operating current the module is designed for.

Imax ... Max. permissible continuous operating current incl. The tolerances of the LED driver.

Max. permissible LF current ripple ... Max. output current of the LED driver incl. Tolerances and LF current ripple must not exceed this value.

Max. permissible peak current ... The max. output peak current of the LED driver must not exceed this value.

5.3 Forward voltage vs. tc temperature

30 40 50 6020 70 80 90tc [°C]

Rel.

forw

ard

volt

age

[%]

90

110

105

100

95

The diagrams are based on statistic values.The real values can be different.

www.tridonic.com 11Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

6.1 Coordinates and tolerances according to CIE 1931

The specified colour coordinates are integral measured by current impulse of 195 mA and a duration of 100 ms.The ambient temperature of the measurement is ta = 25 °C.The measurement tolerance of the colour coordinates are ± 0.01.

3,000 K

x0 y0

Centre 0.4338 0.4030

400 450 500 550 600 650 700 750 8000

20

40

60

80

100

wave length [nm]

norm

. int

ensi

ty [%

]

MacAdam Ellipse: 3SDCM

6. Photometric characteristics

0,3850

0,3900

0,3950

0,4000

0,4050

0,4100

0,4150

0,4200

0,4250

0,4150

0,4200

0,4250

0,4300

0,4350

0,4400

0,4450

0,4500

0,4550

www.tridonic.com 12Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

400 450 500 550 600 650 700 750 8000

20

40

60

80

100

wave length [nm]

norm

. int

ensi

ty [%

]5,000 K

x0 y0

Center 0.3447 0.3553

MacAdam Ellipse: 3SDCM

400 450 500 550 600 650 700 750 8000

20

40

60

80

100

wave length [nm]

norm

. int

ensi

ty [%

]

4,000 K

x0 y0

Center 0.3818 0.3797

MacAdam Ellipse: 3SDCM

0,3350

0,3400

0,3450

0,3500

0,3550

0,3600

0,3650

0,3700

0,3750

0,3250

0,3300

0,3350

0,3400

0,3450

0,3500

0,3550

0,3600

0,3650

0,3600

0,3650

0,3700

0,3750

0,3800

0,3850

0,3900

0,3950

0,4000

0,3650

0,3700

0,3750

0,3800

0,3850

0,3900

0,3950

0,4000

0,4050

www.tridonic.com 13Subject to change without notice. Information provided without guarantee.

Data sheet 07/20-LED509-4

LED modules

LED linear / area

The optical design of the LLE product line ensures optimumhomogeneity for the light distribution.

The colour temperature is measured integral over the complete module. The single LED light points can have deviations in the colour coordinates within MacAdam 5. To ensure an ideal mixture of colours and a homogeneous light distri-bution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 4 cm) should be used.

6.2 Light distribution 6.4 Relative luminous flux vs. operating current

200 300 40010000

20

150

100

200

250

300

500

Operating current [mA]

Rel.

lum

inou

s flu

x [%

]

400 600 80020000

20

150

100

200

250

300

1000

Operating current [mA]

Rel.

lum

inou

s flu

x [%

]

The diagrams are based on statistic values.The real values can be different.

6.3 Relative luminous flux vs. tc temperature

rel.

lum

inou

s fl

ux [a

.u.]

30 40 50 7060tc [°C]

20 8060

80

90

70

100

110

120

90

7.1 Additional information

Additional technical information at www.tridonic.com → Technical Data

Guarantee conditions at www.tridonic.com → Services

Life-time declarations are informative and represent no warranty claim.

7. Miscellaneous

-60°

-50°

-40°-30°

-20°-10° 0° 10° 20°

30°

40°

50°

60°

70°

80°

90°100 10080 8060 6040 4020 200

-90°

20

100

80

60

40

rela

tive

inte

nsity

[%]

LLE 55x280mm 2000lm LV ADV5

LLE 55x566mm 4000lm LV ADV5