LE3 General Purpose Transmitter, Installation and ... I and M.pdf · LE3 General Purpose...
Transcript of LE3 General Purpose Transmitter, Installation and ... I and M.pdf · LE3 General Purpose...
LE3 General Purpose Transmitter, Installation and Maintenance Instructions
www.winters.com WINTERS INSTRUMENTS
Description & Features:• Developed for use in general industry and OEM applications, where versatility and economy are requirements• Compactstainlesssteelconstructionwithceramicsensor• Availablerangesincludein/Hgupto5,000psi• Widerangeofmechanicalandelectricalconnections• ±0.5%accuracy• NEMA4X/IP65andIP67• CE,CSAandRoHScompliant• Approvedforoutdooruse• Customizable• 5yearwarranty
Applications:• Suitableforallprocessandautomationcontrol,hydraulicsand pneumatic sensing, pump and compressor monitoring, refrigeration andHVAC
Specifications
Output SignalStandard2-wire:4-20mA/Vs=8-32VdcOptional3-wire:0-10V/Vs=14-30VdcOptional3-wireratiometric:Vsig=0.5-4.5Vs/Vs=5±0.5Vdc
Accuracy ±0.5%FSO
Permissible Load 2-wire:Rmax=[(Vs-Vsmin)/0.02]Ohm3-wire:Rmin=10kOhm
InfluenceEffects Supply:0.05%FSO/10VLoad:0.05%FSO/kOhm
Response Time 2-wire:<10ms3-wire:<3ms
Measuring Rate 1kHzThermalError <±0.5%FSO/10K
Permissible TemperaturesMedium:-13°Fto257°F(-25°Cto125°C)Electronicsenvironment:-13°Fto185°F(-25°Cto85°C)Storage:-40°Fto185°F(-40°Cto85°C)
Short-circuit Protection Permanent3-wireratiometric:None
Reverse Polarity Protection Nodamage.Nofunction.ElectromagneticProtection EmissionandimmunityaccordingtoEN61326
Stability Vibration:10g,25Hzto2kHzaccordingtoDINEN60068-2-6Shock:500g/1msaccordingtoDINEN60068-2-27
Pollution Degree 4,electricalequipmentforoutdoorusePressure Port / Housing 304SS
Wetted Parts Seals:FKMDiaphragm:CeramicAI2O396%
Weight 120g
Current Consumption2-wire:25mAmax3-wirevoltage:5mA(short-circuitcurrent20mA)3-wireratiometric:1.5mA
Long-term Stability <±0.3%FSO/yratreferenceconditionsOperation Life >100x106 cycles
CEConformityEMCdirective:2004/108/ECPressureequipmentdirective:97/23/EC(moduleA).Validfordeviceswithmaxpermissibleoverpressure>3,000psi
WARNING!READBEFOREINSTALLATION
Fluidhammerandsurgescandestroyanypressuretransmitterandmustalwaysbeavoided.Apressuresnubbershouldbeinstalledtoeliminatethedamaginghammereffects.Fluidhammeroccurswhenaliquidflowissuddenlystopped,aswithquickclosingsolenoidvalves.Surgesoccurwhenflowissuddenlybegun,aswhenapumpisturnedonatfullpoweroravalveisquicklyopened.
Liquidsurgesareparticularlydamagingtopressuretransmittersifthepipeisoriginallyempty.Toavoiddamagingsurges,fluidlinesshouldremainfull(ifpossible),pumpsshouldbebroughtuptopowerslowly,andvalvesopenedslowly.Toavoiddamagefrombothfluidhammerandsurges,asurgechambershouldbeinstalled,andapressuresnubbershouldbeinstalledoneverytransmitter.
Symptomsoffluidhammerandsurge’sdamagingeffects:1.Pressuretransmitterexhibitsanoutputatzeropressure(largezerooffset).Ifzerooffsetislessthan10%FS,usercan usuallyre-zerometer,installpropersnubberandcontinuemonitoringpressures.2.Pressuretransmitteroutputremainsconstantregardlessofpressure.3.Inseverecasestherewillbenooutput.TORQUEREQUIREMENTS:Applypipecompoundsparinglytomalepipethreadsonly.Avoidpipestrainontransmitterhousingbyproperlysupportingandaligningpiping.Applywrenchtothehexflatsoffittingsonly,thentightentheconnection.Adequatesupportofpipingandpropermountingofthepressuretransmittershouldbemadetoavoidexcessiveshockandvibration.TORQUETO125-150poundinches.CAUTION:Forsteamservice,installacondensateloop(pigtailorsteamsiphontube)betweenthesteamlineandthepressuretransmitter.
LE3 General Purpose Transmitter, Installation and Maintenance Instructions
WINTERS INSTRUMENTS www.winters.com
CAN/CSA-C22.2No.61010-1-04-SafetyRequirementsforElectricalEquipmentforMeasurement,ControlandLaboratoryUse,Part1:GeneralRequirements
CalibrationAllmodelsaretestedtomeetorexceedthepublishedspecifications.ThecalibrationandtestingweredoneusinginstrumentationandstandardstraceabletotheNationalInstituteofStandardsandTechnology(NIST).AlsotestedinaccordancewithMIL-STD-45662A.
LE3 General Purpose Transmitter, Installation and Maintenance Instructions
www.winters.com WINTERS INSTRUMENTS
Wiring DiagramStandard Optional
PinConfigurationElectrical Connection ISO 4400 Micro (contact distance 9.4mm) M12x1 (4 pin), plastic Cable Colours (DIN 47100)Supply+ 1 1 1 WhiteSupply- 2 2 2 BrownSignal+ (for 3-wire) 3 3 3 GreenShield Ground pin Ground pin 4 Green/yellow
ElectricalConnectionStandard
Mechanical ConnectionStandard
LE3 General Purpose Transmitter, Installation and Maintenance Instructions
WINTERS INSTRUMENTS www.winters.com
FAULT POSSIBLECAUSE ACTION
No output signal• Novoltagesupply• Transmitterpolarityreversed• Open circuit in electrical wiring
• Checkvoltagesupply• Connectcorrectly• Checkelectricaloutputconnection&wiring
Divergent zero point signal
• Diaphragm is damaged• Operatingtemperaturesaretoohigh/toolow
• Contactthemanufacturer;replacethedeviceif necessary
• Keeptothepermittedtemperaturesshownon the data sheet
Constant output signal with
changing pressure
• Mechanical overload due to over pressure• Electrical fault
• Replacethedevice;incaseofrepeatedfailure, consult the manufacturer
Fluctuating signal span
• TheremaybeasourceofEMCinterferenceinthesurroundingarea(e.g.afrequencyconverter)
• Removethesourceofinterference
Signal span drops / is too small
• Damagetothediaphragm,e.g.duetoim-pacts,abrasive/aggressivemedium;corro-siononthediaphragm/pressureconnection;transmissionmediumnotpresent.
• Contactthemanufacturerandreplacethedevice