1 Software package “KLIMA Software” Ver. 4.1, Windows 10, MS Office 2013 compatible - (C) 2014. Mechanical Software package ‘KLIMA Software’ is developed for designing of HVAC (Heating, Ventilating and Air Conditioning), Water Supply, Fire Fighting and Drainage Buildings and Infrastructure services and consists of 13 mostly interconnected with some independent modules: 1. MODULE 1 - Thermal characteristics of buildings elements MODULE 1A Databases with Materials Thermal and Humidity characteristics and Heat Transfer Coefficients (‘U’ values) estimation. MODULE 1B Water Vapor Diffusion and Condensation within construction elements. MODULE 1C Thermal Stability of Buildings external construction elements. Modules are based on ASHRAE / Serbian standards. 2A. MODULE 2A - Heating Load Heating Load calculation based on DIN 4701 from 1959 or 1983 years and BS/DIN-EN 12831 from 2003, edition 2009. Automatic transfer of ‘U’ values from Module 1. Common building geometry for Modules 2A and 2B. 2B. MODULE 2B - Cooling Load Cooling Load calculation based on Equivalent temperatures and storage coefficients as per Carrier Load estimation manual. Automatic transfer of ‘U’ values from Module 1. Common building geometry for Modules 2A and 2B. 3A. MODULE 3A - Heating Bodies Automatic selection of heating bodies based on the results from the module for Heating Load calculation. Heating bodies can be Radiators, Convectors, Pipe Registers and Heating only FCU-s. Open Database to define new Heating bodies from different manufacturers. 3B. MODULE 3B - Fan Coil Units Automatic selection of Fan Coil Units (FCU-s) based on the results from the module for Cooling Load calculation. FCU-s can be Cooling-Heating or only Cooling. Open Database to define new FCU-s from different manufacturers. 4. MODULE 4 - Pipe Network Two pipes, direct return Heating and Cooling pipe network systems. Automatic transfer of Heating/Cooling capacities from Modules 3A and 3B. Dimensioning, balancing and pressure drop calculations. Flow-Pressure balanced systems with available pressures and required pressure reductions for each of pipe sections. 4WS. MODULE 4WS - Different Water Supply Pipe Networks Independent Module suitable for single pipe Water Supply, Fire Fighting, Irrigation and two pipe direct return Chilled & Hot water - Buildings and Infrastructure pipe networks (Dimensioning, balancing, pressure head calculation, modeling and simulations by input of final consumers water flows in L/s and modeling of simultaneous expected water flows for common pipe sections by input of diversity factors).

Transcript of KLIMA Software - Description

Page 1: KLIMA Software - Description

1

Software package “KLIMA Software” Ver. 4.1, Windows 10, MS Office 2013 compatible - (C) 2014.

Mechanical Software package ‘KLIMA Software’ is developed for designing of HVAC (Heating, Ventilating and Air Conditioning), Water Supply, Fire Fighting and Drainage – Buildings and Infrastructure services and consists of 13 mostly interconnected with some independent modules: 1. MODULE 1 - Thermal characteristics of buildings elements

MODULE 1A Databases with Materials Thermal and Humidity characteristics and Heat Transfer Coefficients (‘U’ values) estimation.

MODULE 1B Water Vapor Diffusion and Condensation within construction elements.

MODULE 1C Thermal Stability of Buildings external construction elements. Modules are based on ASHRAE / Serbian standards.

2A. MODULE 2A - Heating Load

Heating Load calculation based on DIN 4701 from 1959 or 1983 years and BS/DIN-EN 12831 from 2003, edition 2009. Automatic transfer of ‘U’ values from Module 1. Common building geometry for Modules 2A and 2B.

2B. MODULE 2B - Cooling Load

Cooling Load calculation based on Equivalent temperatures and storage coefficients as per Carrier Load estimation manual. Automatic transfer of ‘U’ values from Module 1. Common building geometry for Modules 2A and 2B.

3A. MODULE 3A - Heating Bodies Automatic selection of heating bodies based on the results from the module for

Heating Load calculation. Heating bodies can be Radiators, Convectors, Pipe Registers and Heating only FCU-s. Open Database to define new Heating bodies from different manufacturers.

3B. MODULE 3B - Fan Coil Units Automatic selection of Fan Coil Units (FCU-s) based on the results from the

module for Cooling Load calculation. FCU-s can be Cooling-Heating or only Cooling. Open Database to define new FCU-s from different manufacturers.

4. MODULE 4 - Pipe Network Two pipes, direct return – Heating and Cooling pipe network systems.

Automatic transfer of Heating/Cooling capacities from Modules 3A and 3B. Dimensioning, balancing and pressure drop calculations. Flow-Pressure balanced systems with available pressures and required pressure reductions for each of pipe sections.

4WS. MODULE 4WS - Different Water Supply Pipe Networks Independent Module suitable for single pipe Water Supply, Fire Fighting,

Irrigation and two pipe direct return Chilled & Hot water - Buildings and Infrastructure pipe networks (Dimensioning, balancing, pressure head calculation, modeling and simulations by input of final consumers water flows in L/s and modeling of simultaneous expected water flows for common pipe sections by input of diversity factors).

Page 2: KLIMA Software - Description

2

4DR. MODULE 4DR - Different Drainage Pipe Networks Independent Module suitable for single pipe Sanitary Drainage, Storm Water

and Pumped Drainage - Buildings and Infrastructure Drainage pipe networks (Dimensioning, balancing, pressure drop/head calculation, modeling and simulations by input of final consumers discharge water flows in L/s and modeling of simultaneous expected drainage water flows for common pipe sections by input of diversity factors).

5. MODULE 5 - Duct Network Spiro duct networks with automatic output of Spiro and equivalent Rectangular

duct sizes. Dimensioning, balancing and pressure drop calculations. Flow-Pressure balanced systems with available pressures and required pressure reductions for each of duct sections.

6. MODULE 6 - Bill of Quantities Automatically generated BOQ from previous modules with possibilities to

define other additional and new materials and works. 7. MODULE 7 - Pipe Network Drawings Automatic generation and presentation in AutoCAD of Horizontal Pipe network

and Pipe risers including Heating bodies and all required relevant textual data which were already defined in Modules 3A and 4.

General characteristics of Software package: - Connection between the modules is established by use of transfer files

(including IGES files for the connection with AutoCAD). Transfer files allow for maximum automatic work with minimum input data.

- Interactive data entry is provided by use of menus and predefined Excel data sheets which allow very easy data input even for not very well experienced users, under the MS WINDOWS operating system.

- Results of the calculations for all the modules can be first reviewed on the screen by use of MS Word text editor and after that printed.

- Final results print outs for each of the modules represent final HVAC design documentation.

- The most of the modules can be used independently from other modules.

Page 3: KLIMA Software - Description

3

KLIMA Software – Language and possible Language translations: - Interactive Editor with Menu-s system, Data Input and Data Base Excel Sheets

are in English language. Text that is supposed to be entered within Data input and Data Base Sheets can be in any language as selected within Excel by End User. All Fields description messages and all Fields error messages as results of primary logical control for the type of input text in the Fields and limitations for the minimum or maximum values of data entered in the Fields of Excel Data Sheets are in English language.

- All formatted Results outputs are in Serbian and English languages and are printed in Word document File.

- Error messages as results of detailed logical controls within ‘Fortran’ modules are printed before the Final results outputs into the Word document file. Those Error messages are in Serbian language and can be easily translated by use of, for example, ‘Google Translator’ to any available Language within the Language Translator.

- Final formatted Results outputs from Serbian or English languages, after all Error messages from the Logical Controls are cleared and Data inputs rectified to give clear Final Word document Output File, can be further translated by End User with programming of MS Word Visual Basic Macro commands that will mainly contain ‘Find and Replace Text’ commands. Final formatted Results outputs after activation of ‘Find and Replace Text’ MS Word Macro commands can be in any Language as selected by End User.

- End Users are encouraged to get in contact with us and to offer their MS Word Language Translation produced Macros to other ‘KLIMA Software’ users.

- End Users are encouraged to provide support and trainings to other users. KLIMA Software development, update and maintenance team: Nenad Uzelac, Mechanical Engineer – Engineering consultancy and KLIMA Software developer (Production of new software modules, Update of KLIMA Software, Customer support and Sale. Involved in KLIMA Software team from 1992 up today) Slobodan Dinic, Mechanical Engineer – Engineering and KLIMA Software consultancy (KLIMA Software developer at Initial stage. Main KLIMA Software Initial Concept designer, Consultancy. Involved in KLIMA Software team from 1992 up today) Contact details: For any Information about ‘KLIMA Software’ please contact Nenad Uzelac by E-mail: [email protected] or [email protected]

Page 4: KLIMA Software - Description

4

MORE DETAILS ABOUT ‘KLIMA Software’

1. MODULE 1 – Thermal characteristics of buildings elements 1A. HEAT TRANSFER COEFFICIENTS (‘U’ values) Calculation of heat transfer coefficients (‘U’ values) based on ASHRAE /

JUS.U.J5.510 standards Calculation of minimum building elements thicknesses Automatic preparation of already known and/or estimated ‘U’ values for the

modules for Heating and Cooling load estimations Possibilities to change or enter new data in Excel database sheets with:

thermal characteristics of materials, humidity characteristics of materials, maximum ‘U’ values of building elements, ‘U’ values for glasses, recommended relative humidity and temperatures for the rooms with different purposes.

1B. WATER VAPOR DIFFUSION IN BUILDING CONSTRUCTION ELEMENTS Calculation based on ASHRAE / JUS.U.J5.520 standards Calculation of the water vapor diffusion flow and condensation through the

building construction elements Calculation of the condensate volume Calculation of the drying period for the building construction element Calculation of minimum building elements thicknesses 1C. THERMAL STABILITY OF THE EXTERNAL BUILDING CONSTRUCTION

ELEMENTS IN SUMMER PERIOD Calculation based on ASHRAE / JUS.U.J5.530 standards Calculation of minimum external building construction elements thicknesses

2A. MODULE 2A – HEATING LOAD Heating Load calculation based on DIN 4701 from 1959 or 1983 years and

BS/DIN-EN 12831 from 2003, edition 2009. Possibilities to define typical, equal or similar building construction elements,

equal or similar rooms, zones (groups of rooms, floor levels etc.), which allow for minimum input data

Module limitations: 999 zones in building, 999 rooms in building, 999 typical elements, 999 elements in each room, 2000 typical and coded elements in building

2B. MODULE 2B – COOLING LOAD Cooling Load calculation based on Equivalent temperatures and storage

factors as per Carrier Load estimation manual method Peak load calculation for each room Calculation of maximum simultaneous loads for each zone and for the whole

building Possibilities to calculate cooling loads for the rooms, zones and whole

building for any month, any hour on north and south latitudes Possibilities to define typical, equal or similar building construction elements,

equal or similar rooms, zones (groups of rooms, floor levels etc.), which allow for minimum input data

Page 5: KLIMA Software - Description

5

Geometrical building data inputs for cooling load estimation and heating load estimation need to be defined only once and are used for both modules

Module limitations: 999 zones in building, 999 rooms in building, 999 typical elements, 999 elements in each room, 2000 typical and coded elements in building

3A. MODULE 3A – HEATING BODIES Automatic selection of the types and dimensions of heating bodies based on

the results from Heating Load calculation Possibilities to define new or change existing characteristics of heating bodies

which can be: Radiators, Convectors, Pipe Registers and Heating only Fan Coil Units

Possibilities to select heating body from the group of heating bodies based on limitations for maximum width and/or height and/or depth of heating body

Possibilities to define correction factor for heating related to the conditions of the installation of heating bodies

Automatic preparation of results data for the following modules Module limitations: selection within 16 types of heating bodies internally

preselected from Database, 3000 – total number of heating bodies, 20 heating bodies in one room

3B. MODULE 3B – FAN COIL UNITS Automatic selection of the types and dimensions of Fan Coil Units (FCU-s)

based on the results from Cooling Load calculation Possibilities to define new or change existing characteristics of FCU-s that

can be Cooling-Heating or only Cooling Possibilities to select FCU from the group of FCU-s based on limitations for

maximum width and/or height and/or depth of FCU Possibilities to define correction factor for cooling related to the conditions of

the installation of FCU-s Automatic preparation of results data for the following modules Module limitations: selection within 16 types of FCU-s internally preselected

from Database, 3000 – total number of FCU-s, 20 FCU-s in one room

4. MODULE 4 – PIPE NETWORK Optimal dimensioning of two pipes, direct return Heating and Cooling network

systems Hydraulic estimation and calculation of required pump pressure Flow-Pressure balanced pipe systems with available pressures and required

pressure reductions for each of pipe sections Dimensioning of balancing valves Balancing and determining of the pre regulating positions for balancing valves Use of standard pipes Use of predefined data for balancing valves Possibilities to define new valves of unknown manufacturers Possibilities to define new and/or change already defined data for pipe

connections and local resistances Possibilities to define equal and/or similar pipe risers, that reduce required

data input Preparation of 3-D pipe network model required for module 7 – Pipe network

drawings

Page 6: KLIMA Software - Description

6

Automatic preparation of results data for the following modules Module limitations: 20 - number of standard pipes, 700 pipe sections in pipe

network system, 400 pipe sections with heating/cooling bodies in system, 50 pipe risers in system

4WS. MODULE 4WS - Different Water Supply Pipe Networks Independent Module suitable for single pipe Water Supply, Fire Fighting, Irrigation and two pipe direct return Chilled & Hot water - Buildings and Infrastructure pipe networks (Dimensioning, balancing, pressure head calculation, modeling and simulations by input of final consumers water flows in L/s and modeling of simultaneous expected water flows for common pipe sections by input of diversity factors).

4DR. MODULE 4DR - Different Drainage Pipe Networks Independent Module suitable for single pipe Sanitary Drainage, Storm Water and Pumped Drainage - Buildings and Infrastructure Drainage pipe networks (Dimensioning, balancing, pressure drop/head calculation, modeling and simulations by input of final consumers discharge water flows in L/s and modeling of simultaneous expected drainage water flows for common pipe sections by input of diversity factors).

5. MODULE 5 – DUCT NETWORK Optimal dimensioning of Spiro duct network systems with automatic output of

Spiro and equivalent Rectangular duct sizes Balancing and calculation of required fan pressure Flow-Pressure balanced duct systems with available pressures and required

pressure reductions for each of duct sections Use and selection of standard Spiro ducts as input for calculations Possibilities to define new Control Dampers Possibilities to define new and/or change already defined data for duct

connections and local resistances Possibilities to define equal and/or similar duct risers, that reduce required

data input Preparation of 3-D duct network model required for module 8 – Duct network

drawings (module 8 not yet finalized) Automatic preparation of results data for the following modules Module limitations: 50 - number of standard Spiro ducts, 700 duct sections in

duct network system, 400 duct sections with air diffusers in system, 50 duct risers in system

6. MODULE 6 – Bill of Quantities Automatic preparation of BOQ based on the results data from previous

modules Possibilities to include works which are not included in previous modules

7. MODULE 7 – Pipe Network Drawings Automatically generated AutoCAD drawings from previous modules for

horizontal pipe network and pipe risers showing pipe network data: flows, pipe diameters, dimensions of valves and heating bodies, pre regulating balancing valves positions, etc.

Page 7: KLIMA Software - Description

7

Automatic generation of IGES (Initial Graphics Exchange Standard) files for horizontal network and for each pipe riser

Interpretation of IGES files as a drawings is automatic within AutoCAD Possibilities to use all options of AutoCAD

Interactive Editor for all MODULES Complete Interactive Editor is developed under MS Excel Visual Basic with

Menu-s system, open Databases and Data input Excel Worksheets for all Modules.

Some KLIMA Software Interactive Editor Screenshots:

- Home Page (Screenshot No.1):

Page 8: KLIMA Software - Description

8

- Interactive Menu-s (Screenshot No.2):

- Interactive Menu-s (Screenshot No.3):

Page 9: KLIMA Software - Description

9

- Data Input in one of predefined Excel datasheets (Thermal Characteristics of Buildings Elements – Modul 1):

- Data Input in one of predefined Excel Databases (Thermal Characteristics of Buildings Elements, Maximum U values – Modul 1):

Page 10: KLIMA Software - Description

10

- Data Input in one of predefined Excel datasheets (Cooling Load):

- Data Input in one of predefined Excel datasheets (Fan Coil Units):

Page 11: KLIMA Software - Description

11

- Data Input in one of predefined Excel Databases (Fan Coil Units):

- Data Input in one of predefined Excel Databases (Heating Bodies):

Page 12: KLIMA Software - Description

12

- Data Input in one of predefined Excel datasheets (Pipe network):

Data Input in one of predefined Excel datasheets (Duct network):

Page 13: KLIMA Software - Description

13

- Results preview - Cooling Load calculation (Screenshot No.1):

- Results preview - Cooling Load calculation (Screenshot No.2):

Page 14: KLIMA Software - Description

14

- Results preview - Cooling Load calculation (Screenshot No.3):